• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 128
  • 13
  • 13
  • 13
  • 12
  • 12
  • 11
  • 5
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 132
  • 132
  • 59
  • 52
  • 39
  • 34
  • 31
  • 28
  • 28
  • 23
  • 17
  • 15
  • 15
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Efeito da clorexidina na resistência de união entre adesivo autocondicionante e dentina / Effect of chlorhexidine on bond strength between self-etching adhesive and dentin

Pomacóndor Hernández, César Alberto, 1982- 18 August 2018 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T00:53:20Z (GMT). No. of bitstreams: 1 PomacondorHernandez_CesarAlberto_M.pdf: 1946502 bytes, checksum: 842f8e2e23f8ff6c74e3ea3a3c2f7637 (MD5) Previous issue date: 2011 / Resumo: Na tentativa de prolongar a durabilidade da união resina-dentina, a clorexidina aparece como uma alternativa para preservar a integridade do componente colágeno não envolvido pela camada híbrida. O presente estudo teve como objetivo avaliar o efeito da clorexidina na interação entre o adesivo autocondicionante de dois frascos Adper SE Plus (3M ESPE) e a dentina nas variáveis: a) resistência de união (RU) após 1 dia, 3 meses e 6 meses de armazenamento em água, e b) padrão de fratura. Foram obtidos oito terceiros molares humanos recém extraídos e livres de cárie. O esmalte oclusal e a raiz foram removidos para obter um bloco de dentina de 4mm de espessura com uma superfície plana em dentina média. Cada bloco foi cortado longitudinalmente em duas metades resultando em oito hemiblocos para cada um dos Grupos Controle (C) e Experimental (CHX). Para o Grupo Controle, o Adper SE Plus foi aplicado seguindo as instruções do fabricante: 1 - aplicação do Líquido A, 2 - aplicação ativa do Líquido B por 20s, 3 - leve jato de ar comprimido durante 10s, 4 - aplicação de uma segunda camada de Líquido B, 5 - leve jato de ar comprimido. O adesivo foi fotoativado durante 10s usando a unidade de luz visível Elipar Freelight 2 (3M ESPE) com intensidade de 900 mW/cm2. Para o Grupo Experimental, foi realizado o mesmo procedimento substituindo o Líquido A por uma solução aquosa de digluconato de clorexidina a 2% em peso. Foram construídos blocos de resina composta Filtek Z250 (3M ESPE) sobre a dentina em seis incrementos de 1mm sendo fotoativados durante 20s cada. Depois de 24 horas de armazenamento em água destilada a 37°C, os hemiblocos restaurados foram seccionados perpendiculares à região adesiva nos sentidos mesiodistal e bucolingual e obtidos de 8 a 10 palitos de 0,9mm2 (±0,2mm2), os quais foram divididos aleatoriamente em três grupos de 2 a 4 palitos cada e avaliados após 1 dia, 3 meses e 6 meses de armazenamento em água destilada a 37°C. Para o teste de microtração cada palito foi submetido à tração sob velocidade de 0,5mm/min em uma máquina de ensaios universais. Os valores de RU foram submetidos à Análise de Variância de dois fatores para medidas repetidas (?=0,05), e os padrões de fratura classificados em Microscópio Eletrônico de Varredura. O Grupo Controle apresentou valores de RU estatisticamente não diferentes entre si após 1 dia, 3 meses e 6 meses de armazenamento (46,43±11,46 MPa; 50,02±13,84 MPa; 45,18±17,92 MPa, respectivamente). Os valores de RU do Grupo Experimental também resultaram estatisticamente não diferentes entre si nos mesmos tempos de armazenamento (37,22±10,45 MPa; 47,29±12,67 MPa; 40,22±10,01 MPa, respectivamente). Não houve diferença estatística nos valores de RU entre os Grupos Controle e Experimental. Houve predominância de padrões de fraturas coesiva no adesivo, e mista coesiva no adesivo e na resina composta em ambos os grupos e em todos os tempos de armazenamento. Dentro das condições deste estudo, conclui-se que a RU à dentina do Adper SE Plus não diminuiu com o tempo, e não foi negativamente afetada pela clorexidina a 2% / Abstract: In the search for durability of resin-dentin bond, chlorhexidine appears as an alternative to preserve integrity of collagen component not involved by the hybrid layer. This study aimed to evaluate the effect of chlorhexidine in the interaction between two-bottle self-etching adhesive Adper SE Plus (3M ESPE) and dentin, in terms of bond strength (BS) after 1 day, 3 months and 6 months of water storage, and fracture mode analysis. Eight fresh caries-free human third molars were obtained. The occlusal enamel and roots were removed to obtain a 4mm-thick dentin block with a flat surface in middle dentin. Each dentin block was cut longitudinally into halves resulting in eight hemi-blocks for each of the Control (C) and Experimental (CHX) Groups. For the Control Group, Adper SE Plus was applied following the manufacturer's instructions: 1 - application of Liquid A, 2 - active application of Liquid B for 20s, 3 - gentle compressed air stream for 10s, 4 - application of a second layer of Liquid B, 5 - gentle compressed air stream. The adhesive was light cured for 10s using light unit Elipar Freelight 2 (3M ESPE) with a minimum intensity of 900 mW/cm2. For the Experimental Group, it was performed the same procedure replacing the Liquid A with a solution of 2 wt% chlorhexidine digluconate. Resin composite build-ups were constructed with Filtek Z250 resin composite (3M ESPE) in six increments of 1mm and were light cured for 20s each. After 24 hours storage in distilled water at 37°C, restored hemi-blocks were sectioned perpendicular to the adhesive region in mesiodistal and buccolingual directions and were obtained 8 to 10 beams of 0.9mm2 (±0.2mm2), which were randomly divided into three groups of 2 to 4 beams and evaluated after 1 day, 3 months and 6 months of storage in distilled water at 37°C. For the microtensile test, each beam was tested on tensile until failure at a crosshead speed of 0.5mm/min in a universal testing machine. The BS values were subjected to two-way repeated measures ANOVA (?=0.05), and fracture mode classified in Scanning Electron Microscope. The Control Group had BS values not statistically different from each other after 1 day, 3 months and 6 months of storage (46,43±11,46 MPa; 50,02±13,84 MPa; 45,18±17,92 MPa, respectively). The BS in the Experimental Group also resulted not statistically different from each other at the same times of storage (37,22±10,45 MPa; 47,29±12,67 MPa; 40,22±10,01 MPa, respectively). There was no statistical difference in BS values between Control and Experimental Groups. There was a predominance of cohesive failure within adhesive resin, and mixed cohesive failure within adhesive resin and resin composite in both groups at all storage times. Under the conditions of this study, it can be concluded that BS of Adper SE Plus to dentin did not diminish with time, and was not adversely affected by 2% chlorhexidine / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
62

Resistencia a fratura de pre-molares com preparos cavitarios extensos restaurados atraves de sistemas adesivos e não adesivos

Worschech, Claudia Cia 12 May 2000 (has links)
Orientador : Luis Roberto Marcondes Martins / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T01:38:07Z (GMT). No. of bitstreams: 1 Worschech_ClaudiaCia_M.pdf: 487323 bytes, checksum: 63eea6a7fe297dfbe424400140e629bb (MD5) Previous issue date: 2000 / Resumo: O propósito deste estudo foi avaliar a resistência à fratura de pré-molares superiores com extensos preparos cavitários e restaurados com sistemas adesivos e não adesivos. Trinta pré-molares superiores extraídos e livres de cáries ou fendas foram aleatoriamente divididos em 6 grupos com 5 dentes cada. Os dentes do grupo 1 não receberam preparos cavitários mésio-oclusais (controle positivo). No grupo 2, os dentes receberam preparos cavitários, mas não receberam restaurações (controle negativo). Os grupos 3, 4, 5 e 6 receberam os preparos cavitários e foram restaurados de acordo com os respectivos grupos experimentais: G3: Single Bond + Solitaire; G4: Single Bond + Z250; G5: Amálgama (Dispersalloy); G6: Amálgama (Dispersalloy) + Panavia. Todos os grupos foram submetidos ao teste de resistência à fratura numa Máquina de Ensaio Universal (Instron). O carregamento foi aplicado verticalmente através de uma esfera metálica de 4,7 mm de diâmetro, posicionada sobre as vertentes das cúspides dos pré-molares, numa velocidade de 0,5 mm/ min. As médias de carregamento necessárias para fraturar as amostras em cada grupo foram (em kgf), G6 = 168,46 (A) ; G5 = 155,19 (A) ; G1 = 153,54 (A) ; G4 = 148,86 (A); G3 = 80,08 (B) ; G2 = 20,51 (C). Os resultados do teste de TUKEY revelaram diferenças entre os grupos mostrados acima com letras diferentes. Assim, pôde-se concluir que os pré-molares restaurados através dos materiais citados foram capazes de resistir à fratura tanto quanto um dente íntegro, exceto aqueles restaurados com resina composta Solitaire / Abstract: The aim of this study was to evaluate the fracture resistance of maxillary premolars with large cavities preparations. Thirty extracted maxillary premolars, sound and free from cracks were randomly assigned to six groups of five teeth each. The teeth from group 1 did not receive cavity preparations (positive control). In group 2, the teeth received preparations but did not receive restorations (negative control). From groups 3 to 6, the teeth received MO preparations and were restored according to the following techniques: G3: single Bond + Solitaire; G4: Single Bond + Z250; G5: Amalgam; G6: Amalgam + Panavia. All groups were submitted to fracture resistance test in a Universal Test Machine (Instron). The load was applied vertically through a metallic sphere of 4,7 mm diameter, touching only the cusps and never the restorations or cavity margins. The average load necessary to fracture the samples in each group was (in Kgf), G6= 168,46 (A); G5 = 155,19 (A) ; G1=153,54 (A) ; G4= 148,86 (A); G3= 80,08 (B) ; G2= 20,51 (C). The data were submitted to Tukey¿s test that revealed differences among some groups showed above with different letters. These results show that all materials tested can recover the fracture resistance of maxillary premolars as much as a sound tooth, except Solitaire resin / Mestrado / Dentística / Mestre em Clínica Odontológica
63

Efeito da remoção do colageno na infiltração marginal em restaurações de resina composta utilizando dois sistemas adesivos de frasco unico

Saboia, Vicente de Paulo Aragão 16 February 2001 (has links)
Orientador: Luiz Andre Freire Pimenta / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T00:22:23Z (GMT). No. of bitstreams: 1 Saboia_VicentedePauloAragao_D.pdf: 2377804 bytes, checksum: b83955fe9c76b5de6e7f36a75db01b3f (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar o efeito da remoção do colágeno na infiltração marginal de corante na interface adesiva de restaurações de resina composta utilizando dois sistemas adesivos de frasco único, envelhecidas através de ciclagem térmica e estocagem em água durante 1 ano. Foram usadas 40 raízes de terceiros molares humanos recém-extraídos e armazenados em formol a 10%. A câmara pulpar e o ápice radicular foram vedados com resina composta. Cada raiz recebeu dois preparos cavitários cilíndricos com dimensões de 2 mm de diâmetro por 2 mm de profundidade. Após sorteio, foram criados dois conjuntos de 20 raízes cujas cavidades foram restauradas utilizando-se os adesivos Prime & Bond 2.1 (PB-Dentsply) ou Single Bond (SB-3M). Cada porção radicular recebeu uma restauração pela técnica da hibridização (controle) e outra após o tratamento da dentina com NaOCI (hipoclorito de sódio) a 10% por 60 s para remoção de colágeno (teste). Ficaram estabelecidos 4 grupos de 20 cavidades assim distribuídas: G1(PBSH)-PB sem NaOCI; G2(PBCH)-PB com NaOCI; G3(SBSH)- SB sem NaOCI e G4(SBCH)-SB com NaOCI. Todas as cavidades foram restauradas com resina composta Z 100 (3M) de acordo com as instruções do fabricante. Os espécimes foram submetidos a 5000 ciclos térmicos (5-55 °C) e armazenados em água à 37°C. Após 1 ano, os remanescentes radiculares foram vedados e imersos em solução de azul de metileno a 2% por 4 horas. As restaurações, foram seccionadas no sentido longitudinal da raiz e observadas em lupa estereoscópica com 45 vezes de aumento. De acordo com a penetração do corante nas margens da restauração foram atribuídos escores de 0 a 4, os quais foram tabulados e submetidos ao teste Exato de Fisher. A remoção do colágeno reduziu significativamente os índices de microinfiltração para o adesivo à base de acetona (Prime & Bond 2.1) enquanto que para o adesivo à base de água (Single Bond) este tratamento não influenciou os índices de microinfiltração / Abstract: The aim of this study was to evaluate the effect of collagen removaI on the microleakage of two single-bottle adhesive systems. Forty human third molars were selected and each of them received two preparations on its roots. The roots were randomly assigned to be restored using Prime & Bond 2.1(PB-Dentsply) or Single Bond (SB-3M). One of the cavities in each root was treated with 'H IND. 3¿¿PO IND. 4¿ and the other received an additional treatment with 10% sodium hypochlorite (NaOCI) for 60 s before adhesive application for removaI of collagen layer. Four groups were created: G1(PBSH)-PB without NaOCI; G2(PBCH)-PB with NaOCI; G3(SBSH)-SB without NaOCI and G4(SBCH)-SB with NaOCI. All the cavities were restored with Z 100 restorative resin (3M). The specimens were submitted to 5,000 thermal cycles (5-55 °C) and stored in 37°C water for 1 year. After this time the specimens were coated with a varnish except for 1 mm of tooth structure surrounding the restoration and immersed in 2% blue methylene for 4 hours. After rinsing, the restorations were sectioned and two independent observers, using a light microscopy at x45 magnification, scored (0 - 4) the microleakage at the interface between restorative material and tooth. The scores were submitted to Fisher's Exact Test and the results showed that collagen removal reduced significantly the microleakage for Prime & Bond 2.1 and had not effect on microleakage for Single Bond / Doutorado / Dentística / Doutor em Clínica Odontológica
64

Infiltração marginal em restaurações de amalgama de prata sob influencia de formas de condensação e uso de materiais intermediarios na interface marginal

Pinto, Marcia Bueno 15 December 2000 (has links)
Orientadores: Simonides Consani, Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T05:41:56Z (GMT). No. of bitstreams: 1 Pinto_MarciaBueno_D.pdf: 21339887 bytes, checksum: e010eea03df0ee50f3c87d24d25c9142 (MD5) Previous issue date: 2001 / Resumo: A proposta deste estudo "in vitro" foi avaliar a capacidade de selamento de restaurações de amálgama de prata submetidas à três técnicas de condensação (manual, mecânica e ultra-sônica) utilizando-se, como materiais intermediários, adesivo dentinário, cimento de ionômero de vidro modificado por resina, cimento resinoso, verniz copal e, como controle, somente amálgama. Foram preparadas cavidades tipo classe V na raiz de 210 dentes incisivos de bovinos, com 4 mm no maior tamanho no sentido cervico-oclusal e mésio-distal e 1,5 mm de profundidade com todas as margens localizadas em dentina. Os dentes foram divididos em 5 grupos com 42 dentes em cada um sendo que um dos grupos foi utilizado como controle, sem material intermediário (G1) e cada um dos outros quatro grupo recebeu um material intermediário diferente e as três formas de condensação. Antes da condensação do amálgama (Dispersalloy) as cavidades foram tratadas de acordo com as instruções dos fabricantes com Copalite (G2), Vitremer (G3), Enforce + Prime & Bond 2.1 (G4) e Prime & Bond 2.1(05). As amostras ficaram armazenadas em solução salina durante 30 dias e, a cada 15 dias, foi realizado uma termociclagem que constou de 500 ciclos cada, com tempo de 15 segoem cada banho e temperaturas de 5°C e 55° C. Depois da fadiga térmica as amostras foram mergulhadas em solução de fucsina básica 0,5% à temperatura ambiente durante 24h depois das quais foram lavadas e incluídas em resina acrílica para seccionamento em máquina específica (LABCUT). De cada restauração foram obtidos 3 ou 4 cortes e aquele que apresentou a maior penetração de corante, foi fotografado no Estereomicroscópio e avaliado em graus que variaram entre "0" (sem infiltração) até "3" (máxima infiltração). Os resultados foram submetidos à testes estatísticos de 'X POT. 2¿ e pode-se observar que as formas de condensação não afetaram significativamente a quantidade de infiltração observada. No entanto, quando consideramos apenas a presença ou não de infiltração, os testes estatísticos mostraram que a condensação manual foi superior as outras duas (mecânica e ultrassônica) mostrando uma microinfiltração significativamente menor. Também foi possível verificar que as amostras com Prime & Bond 2.1 e o grupo sem material intermediário mostraram significativamente menos infiltração do que o grupo com Enforce + Prime & Bond 2.1. O grupo com Copalite mostrou um pior resultado apenas quando comparado ao grupo controle sendo semelhante a todos os outros grupos testados. O grupo com Vitremer mostrou-se significantemente melhor do que grupo com Enforce + Prime & Bond 2.1 / Abstract: The purpose of this "in vitro" study was to determine the sealing ability of amalgam restorations submit to 3 condensation techniques underlined with adhesive systems, resin modified glass ionomer, copal varnish and amalgam only, wich was use as control. Class V cavities were made in 210 bovine incisor teeth. The cavities had 4mm in diameter and 1.5mm in depth and were prepared at the root in such way that the margins were established in dentin. Before packing the amalgam (Dispersalloy), the cavities were treated, according to the manufacturer's direction, with Copalite Varnish, Vitremer, Enforce + Prime & Bond 2.1 and Prime & Bond 2.1.The sample remained stored in saline solution for a months and in the meantime they were thennocycled. Each thennocycling comprised of 500 cycles between 5° and 55° C with a dwell time of 15 seconds. After the tennal stress the sample were immersed in 0.5% basic fucsin solution 24 h. and washed. The teeth were embedded in resin acrylic and sectioned in a cutting machine (LABCUT). Three to four buccal-lingual cuts, including the restoration were obtained and the microleakage scored from "0" (no leakage) to "3" (maximum leakage). The highest score for each tooth was considered. Chi-square test was applied to the results and the following observations could be drawn: the 3 different condensation techniques did not significantly affect microleakage. It was also possible to observe that the specimens with Prime & Bond 2.1 and control grup showed signficatly less leakage the Enforce + Prime & Bond 2.1. No significantly difference between Copalite and the other groups, except the was obsered G1(control). The Vitremer was only significantly better than G4 / Doutorado / Doutor em Materiais Dentários
65

Avaliação quantitativa da infiltração marginal em cavidades classe V restauradas com sistemas adesivos monocomponentes e autocondicionantes

Gomes, Fabiana Mantovani 16 February 2001 (has links)
Orientador: Jose Roberto Lovadino / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T12:25:57Z (GMT). No. of bitstreams: 1 Gomes_FabianaMantovani_M.pdf: 3056554 bytes, checksum: c57f84e6ed491583412ec20944275378 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo foi avaliar quantitativamente a microinfiltração em cavidades classe V restauradas com sistemas adesivos monocomponentes e sistemas adesivos autocondicionantes utilizados com e sem condicionamento ácido. Foram avaliados três sistemas adesivos: Clearfil Megabond; autocondicionante; Single Bond; monocomponente contendo água e álcool como solvente; Prime & Bond 2.1; monocomponente contendo acetona como sol vente. Utilizou-se 132 dentes humanos unirradiculares, divididos em 7 grupos, com 20 restaurações classe V e margens em dentina, para cada sistema adesivo; sendo seis grupos testes onde o mesmo sistema adesivo foi utilizado com e sem condicionamento ácido, e um grupo controle negativo em que os dentes foram restaurados em amálgama. Os corpos de prova foram preparados, termociclados, corados com azul de metileno a 2%, seccionados, triturados e avaliados quantitativamente por leitura em aparelho de espectrofotometria. Verificou-se, através do teste ANOV A, que o não condicionamento da dentina não gerou diferença estatística significativa na microinfiltração dos sistemas adesivos; no entanto, quando ocorreu a utilização do condicionamento ácido o sistema adesivo Single Bond demonstrou menor microinfiltração marginal com diferença estatística significativa dos sistemas Clearfil Megabond e Prime & Bond 2.1 que não diferiram entre si. Quando utilizados de acordo com a recomendação do fabricante, os sistemas adesivos Single Bond (utilizado com condicionamento ácido) e Clearfil Megabond (utilizado sem condicionamento ácido) não diferiram entre si, em relação à microinfiltração / Abstract: The aim of this in vitro study was to evaluate the microleakage with espectrofotometric test, in class V restorations restored with one-bottle adhesive systems and self etching systems used with and without etching the dentin. Three kinds of adhesives systems were used: Clearfil Megabond (Kuraray Co.) self etching system; Single Bond (3M Dental Products) one-bottle adesive system, alcohol and water solvent; Prime & Bond 2.1 (Dentsply De Trey) one-bottle adesive system, acetone solvent. One hundred thirty two human teeth (premo lar) were divided in 7 groups, 20 class V restorations were prepared in dentin for each bonding system. The same adhesive were used with and without the etching agent. A group of amalgam restorations were used as a negative controI. The specimens were prepared, dyed with 2% methylene blue, sectioned, triturated, and evaluated with espectrofotometric testo The results were submitted to ANOV A. It was founded that there was no significantly differences in microleakage between the adhesive systems when no etching agent was used; however the Single Bond adhesive system showed statistically significant less microleakage than Clearfil Megabond e Prime & Bond 2.1 when 37% fosforic acid was used to conditioned dentin. The systems Single Bond and Clearfil Megabond had the same behavior when the manufacture instructions were used, the first one used with etching and the last used no etching / Mestrado / Dentística / Mestre em Odontologia
66

Resistencia a fratura de dentes desvitalizados restaurados atraves de resina composta com ou sem pino intra-radicular

Carlini Junior, Bruno 28 June 1999 (has links)
Orientador: Luis Alexandre Maffei Sartini Paulillo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T13:49:09Z (GMT). No. of bitstreams: 1 CarliniJunior_Bruno_M.pdf: 4610426 bytes, checksum: 538cfee8d0c314f1cf2b2aad936f610d (MD5) Previous issue date: 1999 / Resumo: O objetivo deste estudo foi avaliar a influência de pinos intra-radiculares préfabricados sobre a resistência de dentes anteriores tratados endodonticamente, debilitados e restaurados com resina composta, bem como estudar o padrão de fratura. Para isto, oitenta incisivos centrais superiores foram divididos em oito grupos experimentais - dentes com duas cristas marginais removidas: restaurados com compósito odontológico (G1), pino pré-fabricado metálico e compósito (G2) e pino de carbono e compósito (G3); dentes com uma das cristas marginais removidas: restaurados com compósito odontológico (G4), pino metálico mais compósito (G5) e pino de carbono mais compósito (G6); dentes somente com acesso endodôntico restaurados com compósito odontológico (G7); e dentes íntegros como controle (G8). Após a inclusão, dez espécimes de cada grupo foram submetidos ao carregamento tangencial de compressão numa Máquina Universal de Ensaios na velocidade de 0,5mm/min, sob o ângulo de 135°. As médias dos valores de resistência à fratura expressos ~m Kgfforam: G8 = 101,80 (:1: 27,81); G1 = 99,09 (:1: 18,57); G7 = 96,33 (:1: 27,03); G5 = 93,76 (:1: 6,19); G3 = 91,88 (:1: 15,98); G4 = 83,50 (:1: 26,76); G2 = 80,45 (:1: 15,89). A análise estatística não demonstrou diferença significativa entre os grupos (ANO V AlDuncan; a = 0,05). Deste modo, conclui-se que: pinos intra-radiculares não reforçaram dentes anteriores tratados endodonticamente; o fator crista marginal não influenciou na resistência à fratura de dentes anteriores restaurados com resina composta. A avaliação do padrão de fratura demonstrou forte correlação entre presença de pinos intra-radiculares - de carbono ou metálicos - e fraturas radiculares longitudinais (X2 / ~ = 0,66; p < 0,01) / Abstract: The aim of this study was to evaluate the influence of intra-radicular prefabricated posts on the resistance of endodontically treated weakened teeth, restored with composite resin, as well as to study the fracture pattem. Eighty upper central incisors were divided into eight experimental groups - teeth with two marginal bridges removed: restored by composite resin (G 1), metallic prefabricated post plus resin (G2) and carbon fiber post plus resin (G3); teeth with one of the marginal bridges removed: restored by composite resin (G4), metallic post plus resin (G5) and carbon fiber post plus resin (G6); teeth only with endodontic access and restored by composite resin (G7); and sound teeth as control (G8). After the inclusion, ten . specimens of each group were submitted to the compressive force in an Universal Te.sting Machine under 0,5mm/min of velocity and an angle of 135 degrees. The averages ofthe resistance values expressed in Kgfwere: G8 = 101,80 (::I:: 27,81); G1 = 99,09 (::I:: 1.8,57); G7 = 96,33 (::I:: 27,03); G5 = 93,76 (::I:: 6,19); G3 = 91,88 (::I:: 15,98); G4 = 83,50 (::I:: 26,76); G2 = 80,45 (::I:: 15,89). The statistical analysis didn't demonstrate significant difference among the groups (ANO V A/Duncan; a = 0,05). This! results permitted the following conclusions: intra-radicular posts were not able to reinforce endodontically treated teeth; the variable marginal bridge didn't show influence in the fracture resistance of teeth restored with composed resin. The evaluation of the fracture pattem demonstrated strong correlation among presence of intra-radicular posts - metallic or carbon fiber - and radicular longitudinal fractures (X2 / ~ = 0,66; p < 0,01) / Mestrado / Dentística / Mestre em Clínica Odontológica
67

Influencia do remanescente dental do termino gengival e da retenção intra-radicular na resistencia a fratura de restaurações proteicas

Carlini Junior, Bruno 23 October 2001 (has links)
Orientador : Luis Alexandre Maffei Sartini Paulillo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T23:36:23Z (GMT). No. of bitstreams: 1 CarliniJunior_Bruno_D.pdf: 4989185 bytes, checksum: 746f907f11f3e05fc033d327df974b66 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar o padrão e a resistência à fratura de dentes bovinos tratados endodonticamente e restaurados através de coroas unitárias metálicas nas seguintes condições experimentais: presença ou não de remanescente dental coronário com 2 mm de comprimento; término gengival em ombro-biselado, chanfrado e ombro; e dois métodos de retenção intra-coronária, núcleo metálico fundido e pino metálico pré-fabricado paralelo rosqueado. Cento e vinte raízes bovinas receberem tratamento endodôntico e foram fixadas em cilindros de resina acrílica por meio de ligamento periodontal artificial para serem submetidas ao carregamento tangencial de compressão a 0,5 mm/min e 135°, até ocorrer a fratura. Os resultados (ANOVAI DMMQ a=0,05) demonstraram que houve diferença estatística para as condições término gengival (ombro biselado >=chanfrado> ombro), retenção intra-radicular (pino pré-fabricado> núcleo metálico fundido) e presença de remanescente coronário (com remanescente> sem remanescente); bem como para as interações remanescente x pino e remanescente x término, em que os grupos com remanescente apresentaram valores superiores aos grupos sem remanescente, com diferença estatística significativa. Foi possível concluir que a resistência mecânica de raízes reconstruídas proteticamente tem relação com a quantidade de remanescente coronário, método de retenção intra-radicular e formato de término gengival / Abstract: The aim of this study was to evaluate both the pattern and the fracture strength of bovine teeth endodontically treated through metallic unitary crowns under the following experimental conditions: presence or not of dental coronal structure with 2mm in length; cervical beveled shoulder, chamfered and shoulder; and two methods of intraradicular retention, cast post and core and parallel threaded prefabricated metallic posts. Endodontically treated 120 bovine dental roots were fixed to acrylic resin cylinders by means of artificial periodontal ligament, and then submitted to the compressive strength, at 1350 and 0,5 mm/min, until reaching the fracture. The results (ANOVA/ DMMQ a=0,05) showed statistical significance for the following conditions: cervical prosthetic design (beveled sholder >=chanfer > sholder), intraradicular retention (prefabricated posts > cast post and core) and coronal structure (with 2 mm of coronal structure > without dental structure); It was possible to conclude that the mechanical resistance of the restored roots is correlated with the amount of coronary dental structure, the intra-radicular retention method, and the prosthetic gingival shape / Doutorado / Dentística / Doutor em Clínica Odontológica
68

Efeito do laser de CO2 na inibição de carie em esmalte adjacente a restaurações de resina composta : estudo in vitro

Klein, Andre Luiz Lux 05 September 2002 (has links)
Orientador : Marines Nobre dos Santos Uchoa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-01T13:32:42Z (GMT). No. of bitstreams: 1 Klein_AndreLuizLux_M.pdf: 2378651 bytes, checksum: 2d0bfafff06bbebdd19b8c62c7d9eda3 (MD5) Previous issue date: 2002 / Resumo: A presente pesquisa objetivou investigar in vitro o efeito do laser de dióxido de carbono (CO2) sobre a inibição da desmineralização do esmalte ao redor de restaurações de resina composta. Para isto, 60 blocos de esmalte dental humano obtidos de terceiros molares retidos foram aleatoriamente divididos em seis grupos, de acordo com tratamentos da interface esmalte-restauração: I (controle) - cavidade preparada com ponta diamantada + condicionamento ácido + adesivo + restauração com resina; II (controle) - igual ao grupo I menos o condicionamento ácido e -o adesivo; III - igual ao grupo I + 1 Watt; IV -igual ao grupo II + 1 Watt; V - igual ao grupo I + 2 Watts e VI - igual ao grupo 11 + 2 Watts. Após este procedimento, os blocos de esmalte foram submetidos às ciclagens térmica e de pH para simular um alto desafio térmico e cariogênico. A desmineralização do esmalte ao redor das restaurações de resina composta de acordo com os diferentes tratamentos foi quantificada pela análise de microdureza. A perda mineral expressa como ^Z (volume% x µm) e a porcentagem de inibição de cárie dos grupos foi analisada estatisticamente pela análise de variância e teste de Tukey, que inicialmente mostrou que o sistema adesivo não teve nenhum efeito em inibir a perda de mineral próximo à interface dente-restauração. As porcentagens de inibição de cárie para os grupos controle, 1 e 2 Watts a 50 e 100µm foram respectivamente: 42,79%; 46.12%; 53,84% e 57,12%. Concluindo, o uso do laser de CO2 (10,6µm) foi efetivo em inibir a cárie dental adjacente a restaurações de resina composta mesmo em situações de alto desafio cariogênico / Abstract: The present research aimed at investigating the ín vítro effect of a carbon dioxide (CO2) laser on the inhibition of enamel demineralization around composite restoration. For this purpose, 60 human enamel blocks obtained from unerupted third molars were randomly divided into six groups, according to the enamel-restoration interface treatments: I (control) - cavity preparation performed with bur + acid conditioning + adhesive + composite restoration; II (control) ¿ same as I minus acid conditioning and adhesive; III - same as group I + 1 Watt; 'V - same as group 11 + 1 Watt; V - same as group, + 2 Watt; and VI - same as group 11 + 2 Watt. After this procedure, the enamel blocks were submitted to a thermal and pH cycling models to simulate a high thermal and cariogenic challenge. The enamel demineralization around composite resin restorations according to the enamel-restoration interface treatments, was quantified by microhardness analysis. The mineral loss as ^Z (volume % x µm) and percentage of caries inhibition for the groups were statistically analyzed by ANOVA and Tukey test that initially showed that the adhesive system had no effect in inhibiting mineral loss at the enamel-restoration interface. The percentages of caries inhibition for groups control, 1 Watt and 2 Watt at 50µm and 100µm were respectively: 42.79%; 46.12%; 53.84% and 57.12%. In conclusion, the use of a CO2 laser (10.6µm) was effective in inhibiting caries in the enamel adjacent to composite resin restorations even in situations of high cariogenic challenge / Mestrado / Cariologia / Mestre em Odontologia
69

Tendencias da união e adaptação marginal entre dentina e composito odontologico

Montes, Marcos Antonio Japiassu Resende 09 May 2002 (has links)
Orientador : Mario Fernando de Goes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T02:39:27Z (GMT). No. of bitstreams: 1 Montes_MarcosAntonioJapiassuResende_D.pdf: 4527824 bytes, checksum: c03f81bab153f2ba9658374caf302faa (MD5) Previous issue date: 2002 / Resumo: A união ao esmalte é tida como um procedimento estabelecido, já a união à dentina permanece um desafio. Os maiores obstáculos para uma união à dentina são, além da contração de polimerização rígida dos compósitos restauradores, que desafia a interface, a própria dentina como substrato, devido ao seu alto conteúdo orgânico e umidade. Este estudo, buscou avaliar e discutir o conceito de "parede cavitária resiliente" bem como a morfologia das interfaces de união à dentina. Avaliar morfologicamente os efeitos de prétratamentos de superficie para união à dentina, relacionando-os a implicações clínicas. Avaliar a qualidade marginal de cavidades com alto fator-C, com uso de resinas de baixa viscosidade e remoção do colágeno. Avaliar a adaptação interna de cavidades com alto fator-C e margens em dentina, e avaliar e propor um novo método para observação da região desmineralizada na base da camada híbrida. Com base nos resultados, pôde-se concluir que o uso de uma camada intermediária de baixo módulo de elasticidade entre o adesivo e o compósito restaurador pode absorver tensões, melhorando o selamento marginal e preservando a união. Os pré-tratamentos de superficie promovem alterações diferenciadas na dentina, e devem influir nos procedimentos de união. A qualidade marginal foi melhorada com a remoção do colágeno, para o sistema adesivo com acetona, e o uso de uma camada intermediária de baixo módulo de elasticidade para o sistema autocondicionante. Os sistemas adesivos testados não foram capazes de prevenir a nanoinfiltração quando usados de acordo com as recomendações dos fabricantes. A remoção do colágeno melhorou a adaptação interna com o sistema adesivo com acetona, e preveniu a ocorrência da nanoinfiltração. A metenamma de prata mostrou-se um método apropriado para detecção e estudo da nanoinfiltração / Abstract: While bonding to enamel has been considered a reliable procedure, bonding to dentin remains a challenge. There are two major problems related to dentin bonding: the rigid polymerization shrinkage of the restorative composites that challenges the bonded interface; and dentin itself as a bonding substrate, due to its high organic content and its intrinsic wetness. This study, composed by four independent and sequenced articles, had the following objectives. To evaluate and to discuss the "elastic cavity wall" concept and the morphological aspects of the bonded interfaces. To evaluate the morphological effects of surface pre-treatments recommended to dentin bonding, and relate them to clinical implications; To evaluate the marginal quality of restorations in cavities with high C-factor by using low-viscosity resins and afier collagen depletion. To evaluate the internal adaptation in cavities with high C-factor and margins in dentin, and to evaluate and to propose a new method for observations of the demineralized zone at the base of the hybrid layer. The results demonstrated that the use of a low elastic modulus intermediate layer between the adhesive and the composite resin may absorb stress, thereby may enhance the marginal seal and preserve the bond. The surface pre-treatments promoted distinct alterations on dentin, and must influence considerably the bonding procedures. The marginal quality was improved with collagen depletion, afier acid-etching, for the acetonebased adhesive system, and the use of a low elastic modulus intermediate layer for the selfetching primer. The bonding systems tested were unable to prevent nanoleakage when used according to manufacturer's instructions. Collagen depletion enhanced internal adaptation of restorations for the acetone-based system and prevented nanoleakage occurrence. Silver methenamine staining is a useful method to detect nanoleakage / Doutorado / Doutor em Materiais Dentários
70

Efeito do tempo na resistencia da união de composito para cimentação sobre dentina e composito de baixa viscosidade

Duarte, Rosangela Marques 04 March 2003 (has links)
Orientador: Mario Fernando de Goes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T18:09:00Z (GMT). No. of bitstreams: 1 Duarte_RosangelaMarques_D.pdf: 3969669 bytes, checksum: 5d104042597bd78c90263b5527023ba8 (MD5) Previous issue date: 2003 / Resumo: O objetivo deste estudo foi avaliar a resistência da união à tração de sistemas adesivos autocondicionantes em combinação com o compósito para cimentação Panavia F (PF) sobre dentina recém cortada e após forramento com o compósito de baixa viscosidade Protect Liner F (PL). Superfícies dentinárias planas foram preparadas nas faces vestibulares de 60 incisivos inferiores bovinos. Para a delimitação da área de união foi utilizada fita adesiva contendo orifício de 4,0 mm de diâmetro. Nos grupos A I, A II e A m foi aplicado o sistema adesivo autocondicionante ED Primer componente do sistema de cimentação adesiva PF. Nos grupo B I, B II e B m foi aplicado o sistema adesivo autocondicionante Clearfil Liner Bond 2V (CLB2V), seguido da aplicação de camada de compósito de baixa viscosidade PL. Em seguida, o compósito para cimentação PF foi aplicado, o cilindro de compósito (Z100) posicionado sobre a área de união delimitada e o compósito fotoativado por 20 segundos em três pontos da interface de união, totalizando 60 segundos. O ensaio de tração foi realizado em máquina de ensaio universal Instron, com velocidade de 0,5 mm/minuto e conduzido após 1O minutos da união para os grupos A I e B I, 24 horas da união para os grupos A II e B II e após 12 meses de armazenagem para os grupos A m e B 111. O tipo de fratura foi observado e classificado em Microscopia Eletrônica de Varredura. Os resultados foram submetidos à análise de variância e_ ao teste de Tukey (p<0,05). Os resultados do ensaio de tração expressos em MPa foram: Grupo A 1 - 9,32 :i: 2,39ab; Grupo A II - 10,16 :i: 1,22a; Grupo A m - 8,47:i: 1,52b; Grupo B 1- 10,58 :t 2,19ab; Grupo B II - 11,31 :t 2,06a; Grupo B m - 9,74:t 1,61b. Não houve diferença estatística significativa entre 10 minutos e 24 horas (p>O,OS) para os grupos testados. Entre 24 horas e 12 meses os valores médios de resistência de união à tração foram estatisticamente inferiores (p<O,OS) para os grupos A li e B li. Os grupos que utilizaram o sistema de cimentação PF sobre a dentina forrada com o compósito de baixa viscosidade PL foram estatisticamente superiores aos grupos do PF sobre dentina para todos os períodos (p<O,O5). A fratura com predominância estatística para os grupos A I, A TI e A TIl foi coesiva no adesivo/camada híbrida e para os grupos B I, B II e B III foi coesiva no compósito. A técnica do uso do compósito de baixa viscosidade PL, "resin coating", proporcionou a proteção do complexo hibridizado, mantendo o se lamento dos túbulos dentinários durante o período de 12 meses de armazenagem em água / Abstract: The purpose of this study was to evaluate the tensile bond strength (TBS) of self-etehing primers, ED Primer (ED) and Clearfil Liner Bond 2V (CLB2V), assoeiated with Panavia F (PF) resin eement on dentin and resin eoated dentin at 10 minute, 24h and 12 months afier euring. Flat dentin surfaees were prepared on labial surfaee of 60 bovine ineisor teeth and a 4.0-mm-diameter bonding area was demarcated on eaeh prepared surfaee with adhesive vinyl tape. On the dentin surfaee of the A I, A 11 and A 111 Groups (Gs) were applied ED and in the B I, B 11 and B 111 Gs was applied CLB2V followed by Proteet Liner F (PLF) and PF. A resin eomposite rod was positioned on the bonding area and eured for 20s at the three points of the interfaee to perform the TBS test using an Instron maehine (0.5 mm/min) at 10 minute to AI and BI Gs and 24h afier euring to Ali and BII Gs. A 111 and B 111 Gs were submitted to TBS test afier 12 months storage. The results were analyzed by ANOVA and Tukey's test (p< 0.05). Fracture modes and interfaee adhesive-dentin were observed at SEM. The TBS results in MPa were: A I - 9.32 :t 2.39; AlI - 10.16:t 1.22; A m - 8.47:t 1.52; B I-10.58:t 2.19; B 11 -11.31 :t 2.06; B m - 9.74:t 1.61. There was no statistically significant differenee (p<0.05) among eaeh themselves Gs at 10 minute and 24 h. A m and B m Gs showed the lowest TBS values (p<0.05) afier 12 months storage. PF resin eement on resin eoated dentin (PLF) showed the highest TBS and was statistically different (p<0.05) than PF on dentin at 10 min, 24 h and 12 months. The fracture pattem was cohesive on the adhesivelhybrid layer for A I, A 11 and A 111 Gs and cohesive on eomposite resin for B I, B 11 and B m. The coneept of coating the prepared dentin with adhesive system and low viscosity composite resin showed a protection of the hybridized complex with a dentin seal during the 12 months storage period / Doutorado / Doutor em Materiais Dentários

Page generated in 0.0196 seconds