• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 152
  • 51
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 211
  • 211
  • 146
  • 104
  • 64
  • 63
  • 57
  • 42
  • 41
  • 26
  • 25
  • 25
  • 25
  • 24
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Avaliação da alteração de cor e rugosidade média superficial de resinas acrílicas usadas em base de próteses após imersão em desinfetantes químicos e bebidas / Evaluation of the color alteration and superficial roughness of the denture base acrylic resins after immersion in chemical didinfectants and beverages

Fernandes, Flávio Henrique Carriço Nogueira 24 September 2009 (has links)
Pacientes submetidos a procedimento protéticos estão expostos a microorganismos patogênicos podendo ocorrer desenvolvimento de doenças e infecção cruzada entre pacientes e equipe odontológica.As próteses devem ser desinfetadas com substâncias que não provoquem alterações nas propriedades mecânicas e físicas principalmente em associação com a ingestão de bebidas com teor alcoólico ou baixo pH. O objetivo desse estudo foi avaliar a rugosidade média superficial (Ra) e estabilidade de cor de resinas acrílicas(Lucitone 550, QC-20 e Vipi-Wave), empregadas na confecção de bases para próteses totais, removíveis, overdentures e próteses protocolos sobre implantes após imersão em desinfetantes químicos (hipoclorito de sódio 1% e ácido peracético 2%) por 30 e 60 minutos, e após desinfecção por 30minutos seguida de imersão em bebidas com e sem teor alcóolico (vinho, suco de uva, chá e aguardente). Foram confeccionados 60 corpos-de-prova de cada marca comercial de resina, sendo divididos em 2 grupos, referentes aos desinfetantes químicos. Após os procedimentos de acabamento e polimento dos corpos-de-prova, foram realizadas as mensurações iniciais (t=0) de rugosidade e cor, e a seguir dez corpos-de-prova de cada marca comercial de resina foram imersos em hipoclorito de sódio e dez em ácido peracético, durante 30 e 60 minutos, sendo realizadas as mensurações após cada período de imersão. Esses dados foram, posteriormente submetidos à análise estatística. Quarenta corpos-de-prova de cada tipo de resina foram imersos em hipoclorito de sódio e ácido peracético por 30min, a seguir foram realizadas as mensurações de rugosidade e cor, e a divisão em subgrupos referentes às bebidas. Os corpos-de-prova foram lavados com água destilada, secos com lenços de papel e imersos em vinho(n=5), suco de uva(n=5), chá (n=5) e aguardente (n=5) por 2 horas. Após as mensurações, os corpos-de-prova foram imersos em água destilada e mantidos por 24 horas, decorrido esse período foram realizadas as mensurações de rugosidade e cor. Os corpos-de-prova eram imersos diariamente nas bebidas por 2 horas e as mensurações subseqüentes de rugosidade e cor eram realizadas após 168hs (7dias), 336hs (14dias) e 504hs (21dias) de imersão nas mesmas bebidas.Os dados foram analisados estatisticamente pela Análise de Variância e testes complementares de Tukey e Scheffé. Foi evidenciado aumento da Ra após 30 minutos de imersão nos desinfetantes em todas as resinas, com QC-20 apresentando os maiores valores de Ra e Vipi-Wave os menores. Lucitone 550 apresentou maior Ra após imersão em vinho, suco de uva e aguardente e Vipi-Wave após imersão em chá. Após 60minutos de imersão nos desinfetantes todas as resinas apresentaram alteração de cor estatisticamente significante. Os corpos-de-prova imersos em vinho apresentaram os maiores valores de alteração de cor após 336hs (14dias), enquanto os imersos em suco de uva apresentaram alterações de cor leves após 168hs (7dias), 336hs (14dias) e 504hs (21dias), e os imersos em aguardente e chá não apresentaram alterações de cor clinicamente significantes. Conclui-se que desinfecção em hipoclorito de sódio 1% e ácido peracético alterou as propriedades de rugosidade média e cor das resinas avaliadas, e dentre as bebidas, vinho e suco de uva foram as que propiciaram maior alteração de cor. / Patients submitted to prosthetic procedures are exposed to pathogenic microorganisms, and the development of diseases and crossed infection may occur between patients and the dental team. Dentures must be disinfected with substances that do not cause changes in the mechanical and physical properties, particularly in association with the ingestion of beverages with alcohol concentration or low pH. This study evaluated the surface roughness (Ra) and color stability of acrylic resin colors (Lucitone 550, QC-20 and Vipi-Wave), used for fabricating bases for complete, removable dentures, overdentures and prosthetic protocol after immersion in chemical disinfectants (1% sodium hypochlorite and 2% peracetic acid) for 30 and 60 minutes, and after disinfection, followed by immersion in beverages (wine, grape juice, tea and brandy) for 30minutes. Sixty specimens were made of each commercial brand of resin composite, and divided into 2 groups according to the chemical disinfectants. After the test specimens had undergone the finishing and polishing procedures, the initial color and roughness measurements were taken (t=0), and after this, tem test specimens of each commercial brand of resin composite were immersed in sodium hypochlorite and ten in peracetic acid, for 30 and 60 sixty minutes, with measurements being taken after each immersion period. Afterwards, these data were submitted to statistical analysis. Forty test specimens of each type of resin were immersed in sodium hypochlorite and peracetic acid for 30 min, after which roughness and color measurements were taken, and specimens were divided into subgroups according to the beverages. The specimens were washed with distilled water, dried with paper towels and immersed in wine (n=5), grape juice (n=5), tea (n=5) and brandy (n=5) for 2 hours. After being measured, the test specimens were immersed in distilled water and kept there for 24 hours. When this period elapsed, roughness and color were measured. The test specimens were immersed for 2 hours daily, and the subsequent roughness and color measurements were taken 168 hrs (7days), 336 hrs (14days) and 504 hrs (21days) after immersion in the same beverages. The data were statistically analyzed by the Analysis of Variance and Tukey and Scheffé complementary tests. There was evidence of an increase in Ra after 30 minutes immersion in the disinfectants in all the resins, with QC-20 presenting the highest Ra values, and Vipi-Wave the lowest. The Lucitone 550 resin presented the highest Ra after immersion in wine, grape juice and brandy, and Vipi-Wave after immersion in tea. After 60 minutes immersion in the disinfectants all the resins presented statistically significant color alteration. The test specimens immersed in wine presented the highest color alteration values after 14 days, while those immersed in grape juice presented slight color alterations after 168 hrs (7days), 336hrs (14days) and 504hs (21days), and those immersed in brandy and tea presented no clinically significant color alterations. It was concluded that disinfection in 1% sodium hypochlorite and peracetic acid altered the properties of roughness and color of the evaluated resins, and among the beverages, wine and grape juice were those that produced the greatest color alteration.
172

Influência da desinfecção química e do tempo de armazenagem sobre as propriedades físicas das próteses oculares /

Moreno, Amália. January 2011 (has links)
Orientador: Marcelo Coelho Goiato / Coorientador: Daniela Micheline dos Santos / Banca: Simone Cecílio Hallak Regalo / Banca: Stefan Fiuza Carvalho Dekon / Resumo: As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. Assim, os materiais utilizados na confecção de prótese ocular devem possuir propriedades específicas para sua indicação e durabilidade. Desse modo, é importante avaliar o comportamento destes materiais quando influenciados por diversas soluções desinfetantes. Este estudo teve como objetivo avaliar a microdureza, rugosidade superficial e alteração de cor de próteses oculares sobre a influência da desinfecção química e armazenagem. Foram confeccionadas 50 amostras simulando próteses oculares contendo duas resinas acrílicas (N1 e incolor), distribuídas em cinco grupos de acordo com o desinfetante utilizado: sabão neutro (I), opti-free (II), efferdent (III), hipoclorito a 1% (IV) e clorexidina a 4% (V). As amostras foram armazenadas por 120 dias, sendo desinfetadas durante este período. As leituras de microdureza, rugosidade e cor das amostras foram realizadas em um período inicial (B) e após 60 (T1) e 120 (T2) dias de armazenagem com desinfecção. A microdureza foi mensurada por meio de um microdurômetro, e a rugosidade determinada por um rugosímetro. A leitura de cor foi realizada por meio da espectrofotometria de reflexão, usando o sistema CIE L*a*b*. A alteração de cor (ΔE) foi calculada para os períodos entre T1 e B (T1B), e T2 e B (T2B). Pelos resultados obtidos a resina N1 para esclera apresentou menor microdureza estatisticamente significante, comparada a resina incolor (P<0,05). A maior alteração dos valores de microdureza e rugosidade foi obtida para os grupos IV e V. Ambos os períodos de desinfecção e armazenagem produziram alterações significativas (P<0,05) nas amostras com diminuição dos valores de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Ocular prostheses are responsible to restore not only patient's aesthetic but also its self-esteem. The materials used to fabricate the ocular prostheses should present specific properties regarding its indication and durability. Therefore, it is important to investigate the physical behavior of such materials when subjected to different disinfectant solutions. This study evaluated the microhardness, surface roughness and color stability of ocular prostheses under the influence of different chemical disinfectant solutions and storage. A total of 50 samples simulating an ocular prosthesis containing two acrylic resins (N1 and colorless) were fabricated. They were divided into five groups as a function of disinfectant solution: neutral soap (I), opti-free (II), efferdent (III), 1% hypochlorite (IV) and 4% chlorhexidine (V). Samples were storage during 120 days, and they were disinfected throughout the period. Microhardness, roughness and color measurements were performed at baseline (B), after 60 (T1) and 120 (T2) days of storage with disinfection. The microharness and the roughness measurements were evaluated using a microdurometer and a roughness meter, respectively. Samples colors were measured with spectrophotometer using CIE L*a*b* system. Color differences (ΔE*) were calculated for periods between T1 and B (T1B), and T2 and B (T2B). The N1 acrylic resin exhibited statistically lower microhardness when compared to the colorless acrylic resin (P<0.05). The highest microhardness and roughness alterations were observed for groups IV and V. Both disinfection and storage periods statistically reduced the microhadness values and increased the roughness values of the samples (P<0.05). Color alteration was... (Complete abstract click electronic access below) / Mestre
173

Posttreatment stability of lip bumper therapy

Kimura, Rui Yoshio, January 2002 (has links) (PDF)
Thesis--University of Oklahoma. / Includes bibliographical references (leaves 99-101).
174

Análise por computação gráfica da variação da posição relativa dos dentes artificiais antes e após o processamento de próteses totais superiores

Shibayama, Ricardo [UNESP] 19 September 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-09-19Bitstream added on 2014-06-13T19:37:38Z : No. of bitstreams: 1 shibayama_r_me_araca.pdf: 3106543 bytes, checksum: c84fd00a6f34341aaf54e2572db11b66 (MD5) / Investigamos a alteração da posição dos dentes artificiais durante o processamento de próteses totais, utilizando as resinas de marcas comerciais QC 20 (Dentsply) e Onda Cryl (Clássico - específico de microondas), com inclusão em gesso e com muralha de silicone, polimerizadas tanto pelo método de banho por água quente, quanto pela polimerização por energia de microondas. Foram utilizadas 40 amostras, divididas em 4 grupos de 10, que receberam os seguintes tipos de processamento. a) grupo 1: incluídos em muflas metálicas com muralha de gesso pedra e polimerização convencional. b) grupo 2: incluídos em muflas de fibra de vidro com muralha de gesso pedra e polimerização com microondas. c) grupo 3: incluídos em muflas metálicas com muralha de silicone e polimerização convencional. d) grupo 4: incluídos em muflas de fibra de vidro com muralha de silicone e polimerização por energia de microondas. Para detecção dos deslocamentos dentais utilizamos um guia de resina acrílica com 5 pontos pré-determinados que proporcionou pontos de referência nas réplicas que permitiram mensurar tais deslocamentos através da utilização do programa de computador AutoCad. Com os resultados obtidos podemos concluir que: a) todas as amostras sofreram alteração da posição dos dentes após o processamento, b) a técnica com a menor movimentação dos dentes artificiais foi a técnica 4. / This study investigated artificial tooth movement during the procedures of complete dentures base, using two different types of resins: QC 20 (Dentsply) and OndaCryl (Clássico specify for microwave energy), with gypsum stone mould and silicone mould. We used thermopolymerization in water bath and microwave polymerization. The forty samples utilized were divided into four groups of ten, which received the following type of inclusion and processing. Group 1: included in metallic flasks with gypsum stone mould and thermopolymerization in water bath and microwave polymerization; Group 2: included in resin-fiber glass flasks with gypsum stone mold and microwave polymerization; Group 3: included in metallic flasks with silicone mold and thermopolymerization in water bath; Group 4: included in resin-fiber glass flasks with silicone mould and microwave polymerization. For the measurement of artificial tooth movement, we used a resin acrylic guide with five daily determined points which provide references points. The AutoCad R 14 computer program was utilized for the measurements. All data were submitted to ANOVA and Tukey test. With the results we can conclude that: a) all the samples suffer artificial tooth movement, b) the smaller artificial tooth movement happen in group four.
175

Caracterização de materiais experimentais e comerciais para reembasamento imediato por meio de análise de propriedades físico-químicas e mecânicas /

Reis, José Mauricio dos Santos Nunes. January 2009 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Renata Cunha Matheus Rodrigues Garcia / Banca: Karin Hermana Neppelenbroek / Banca: João Neudenir Ariolli Filho / Banca: Eunice Teresinha Giampaolo / Resumo: Este estudo avaliou o comportamento exotérmico de 5 resinas rígidas para reembasamento imediato, duas experimentais (E1 e E2) à base de agentes de ligação cruzada (etileno glicol dimetacrilato e 1,4-butanediol dimetacrilato) e três comerciais (Kooliner-K, New Truliner-NT, Tokuyama Rebase II-TR II), bem como o grau de conversão (GC), a sorção (Sor) e a solubilidade (Sol) em água, a contração linear de polimerização (CLP), as propriedades viscoelásticas e a resistência à flexão desses materiais e de uma resina para base de prótese (Lucitone 550-L). Foi avaliada, ainda, a resistência de união (RU) entre os reembasadores e a resina de base. O comportamento exotérmico foi avaliado (n=4) com termopar tipo K inserido no interior das resinas, em matriz circular (60 x 2,0 mm), e mantido até a polimerização. O GC (%) foi avaliado (n=5) por espectroscopia de infravermelho por transformadas de Fourier (32 leituras; resolução 4,0 cm-1). A Sor e a Sol (μg/mm3) foram mensuradas (n=5) seguindo as recomendações da ISO 1567. A CLP (%) foi avaliada (n=10), em projetor de perfil (Nikon 6C), em corpos-de-prova circulares (50 x 0,5 mm). Para avaliar as propriedades viscoelásticas, corpos-de-prova (40 x 10 x 3,3 mm) foram submetidos (n=2) à análise térmica dinâmico-mecânica (DMTA) em diferentes intervalos de temperatura (ciclos). O módulo de armazenamento (E') e o amortecimento mecânico (tan δ) a 37ºC foram registrados durante o primeiro e último ciclo da DMTA. A temperatura de transição vítrea (Tg) foi mensurada somente no último ciclo da DMTA. Os ensaios mecânicos de flexão (0,5 mm/min) foram realizados (n=10) em corpos-de-prova (64 x 10 x 3,3 mm) intactos ou reembasados e a resistência (MPa) calculada na tensão máxima (RFM) e no limite de proporcionalidade (RFLP). Para avaliar a RU (MPa) entre os materiais, 60 cilindros (20 x 20 mm) da resina L foram processados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the exothermic behavior, degree of conversion (DC), water sorption (WSor), water solubility (WSol), linear polymerization shrinkage (LPS), viscoelastic properties and flexural strength of 5 hard chairside reline resins, two experimental (E1 and E2) based on crosslinking agents (ethylene glycol dimethacrylate and 1,4-butanediol dimethacrylate) and three commercially available (Kooliner-K, New Truliner-NT and Tokuyama Rebase II-TR II), and one heat-polymerized denture base resin (Lucitone 550-L). The shear bond strength (SBS) between the denture base resin and the reline materials was also evaluated. The exothermic behavior of circular specimens (60 x 2.0 mm) during polymerization was assessed (n=4) using a type K thermocouple. The DC (%) was measured (n=5) by Fourier Transformed infrared-attenuated total reflectance (FTIR-ATR) spectroscopy (32 scans; resolution of 4.0 cm-1). WSor and Wsol (μg/mm3) were determined (n=5) according to the recommendation stated in ISO 1567. The LPS (%) was measured (n=10) in circular specimens (50 x 0.5 mm) using a perfilometer (Nikon 6C). The viscoelastic properties of the specimens (40 x 10 x 3.3 mm) were evaluated (n=2) by dynamical-mechanical thermal analysis (DMTA) under different temperature ranges (runs). Values of storage modulus (E') and loss tangent (tan δ) at 37ºC were obtained from the first and last runs. The glass transition temperature (Tg) was only measured from the last run. Ultimate flexural strength (UFS - MPa) and flexural strength at the proportional limit (FSPL - MPa) were determined (n=10) by three-point test (0.5 mm/min) using intact and relined specimens (64 x 10 x 3.3 mm). To evaluate the SBS between the materials, 60 cylinders (20 x 20 mm) of the denture base resin L were processed, relined (3.5 x 5.0 mm) and submitted to shear testing (0.5 mm/min). Data were analyzed by ANOVA and Tukey... (Complete abstract click electronic access below) / Doutor
176

Avaliação clínica da estabilidade dimensional de próteses totais submetidas à desinfecção por microondas

Basso, Michael Frederico Manzolli [UNESP] 27 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-27Bitstream added on 2014-06-13T21:07:01Z : No. of bitstreams: 1 basso_mfm_dr_arafo.pdf: 618642 bytes, checksum: a30b4dfd3eaaae29f0c670dfb57dbd55 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A energia por microondas tem sido recomendada para desinfetar próteses totais. Entretanto, os ciclos de desinfecção podem afetar a estabilidade dimensional das bases de próteses. Assim, o objetivo deste estudo clínico foi avaliar o efeito de dois protocolos de desinfecção por microondas na estabilidade dimensional de próteses totais, analisando a estabilidade dimensional linear, o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos e as ocorrências clínicas. Foram confeccionadas próteses totais para quarenta pacientes totalmente edêntulos. Todas as próteses foram prensadas com a resina Lucitone 550. Após a colocação, aguardou-se 30 dias para submeter as próteses às condições experimentais como a seguir: Grupo 1 (G1)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), uma vez por semana, durante 4 semanas. Grupo 2 (G2)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), três vezes por semana, durante 4 semanas. Para avaliar a estabilidade dimensional linear, mensurações foram realizadas entre quatro pontos de referência (primeiros pré-molares e segundos molares bilateralmente) antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção. Um software foi utilizado para mensurar as distâncias entre os pontos de referência a partir de fotografias padronizadas. As dimensões médiolateral e anteroposterior e a área foram calculadas. Os dados foram analisados pelos testes ANOVA two-way, Tukey e t-Student (_=0,05). O sistema T-Scan III foi utilizado para avaliar o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos. Os contatos oclusais cêntricos foram capturados, antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção, por meio... / Microwave energy has been recommended for disinfecting complete dentures. However, the microwave disinfection cycles may affect the dimensional stability of denture bases. Therefore, the purpose of this clinical study was to evaluate the effect of two microwave disinfection protocols on the dimensional stability of complete dentures, analyzing the linear dimensional stability, the percent occlusal force obtained from centric occlusal contacts and the clinical events. Complete dentures were constructed for forty totally edentulous patients. All dentures were conventionally processed with heat-polymerized acrylic resin (Lucitone 550). After insertion of complete dentures, it was expected 30 days to submit the dentures to the experimental conditions as follows: Group 1 (G1)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), once a week, for four weeks. Group 2 (G2)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), three times a week, for four weeks. To evaluate the linear dimensional stability, measurements were taken across four reference points (first premolars and second molars bilaterally) before of first microwave disinfection (baseline) and after each week of disinfection. Software was used to measure distances between reference points from standardized photographs. Mediolateral and anteroposterior dimensions and area between reference points were calculated. The dimensional data obtained were analyzed using two-way ANOVA, Tukey test and t test (_ = .05). To evaluate the percent occlusal force obtained from centric occlusal contacts, the T-Scan III system was used. The centric occlusal contacts were measured, before of first microwave disinfection (baseline) and after each week of disinfection, using pressure-sensitive sheets and studied in T-Scan software. The occlusal data... (Complete abstract click electronic access below)
177

Caracterização de materiais experimentais e comerciais para reembasamento imediato por meio de análise de propriedades físico-químicas e mecânicas

Reis, José Mauricio dos Santos Nunes [UNESP] 03 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-03Bitstream added on 2014-06-13T19:44:47Z : No. of bitstreams: 1 reis_jmsn_dr_arafo.pdf: 1310753 bytes, checksum: 17bd719b0c46c00b10cbd2db022db42a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou o comportamento exotérmico de 5 resinas rígidas para reembasamento imediato, duas experimentais (E1 e E2) à base de agentes de ligação cruzada (etileno glicol dimetacrilato e 1,4-butanediol dimetacrilato) e três comerciais (Kooliner-K, New Truliner-NT, Tokuyama Rebase II-TR II), bem como o grau de conversão (GC), a sorção (Sor) e a solubilidade (Sol) em água, a contração linear de polimerização (CLP), as propriedades viscoelásticas e a resistência à flexão desses materiais e de uma resina para base de prótese (Lucitone 550-L). Foi avaliada, ainda, a resistência de união (RU) entre os reembasadores e a resina de base. O comportamento exotérmico foi avaliado (n=4) com termopar tipo K inserido no interior das resinas, em matriz circular (60 x 2,0 mm), e mantido até a polimerização. O GC (%) foi avaliado (n=5) por espectroscopia de infravermelho por transformadas de Fourier (32 leituras; resolução 4,0 cm-1). A Sor e a Sol (μg/mm3) foram mensuradas (n=5) seguindo as recomendações da ISO 1567. A CLP (%) foi avaliada (n=10), em projetor de perfil (Nikon 6C), em corpos-de-prova circulares (50 x 0,5 mm). Para avaliar as propriedades viscoelásticas, corpos-de-prova (40 x 10 x 3,3 mm) foram submetidos (n=2) à análise térmica dinâmico-mecânica (DMTA) em diferentes intervalos de temperatura (ciclos). O módulo de armazenamento (E’) e o amortecimento mecânico (tan δ) a 37ºC foram registrados durante o primeiro e último ciclo da DMTA. A temperatura de transição vítrea (Tg) foi mensurada somente no último ciclo da DMTA. Os ensaios mecânicos de flexão (0,5 mm/min) foram realizados (n=10) em corpos-de-prova (64 x 10 x 3,3 mm) intactos ou reembasados e a resistência (MPa) calculada na tensão máxima (RFM) e no limite de proporcionalidade (RFLP). Para avaliar a RU (MPa) entre os materiais, 60 cilindros (20 x 20 mm) da resina L foram processados... / This study evaluated the exothermic behavior, degree of conversion (DC), water sorption (WSor), water solubility (WSol), linear polymerization shrinkage (LPS), viscoelastic properties and flexural strength of 5 hard chairside reline resins, two experimental (E1 and E2) based on crosslinking agents (ethylene glycol dimethacrylate and 1,4-butanediol dimethacrylate) and three commercially available (Kooliner-K, New Truliner-NT and Tokuyama Rebase II-TR II), and one heat-polymerized denture base resin (Lucitone 550-L). The shear bond strength (SBS) between the denture base resin and the reline materials was also evaluated. The exothermic behavior of circular specimens (60 x 2.0 mm) during polymerization was assessed (n=4) using a type K thermocouple. The DC (%) was measured (n=5) by Fourier Transformed infrared-attenuated total reflectance (FTIR-ATR) spectroscopy (32 scans; resolution of 4.0 cm-1). WSor and Wsol (μg/mm3) were determined (n=5) according to the recommendation stated in ISO 1567. The LPS (%) was measured (n=10) in circular specimens (50 x 0.5 mm) using a perfilometer (Nikon 6C). The viscoelastic properties of the specimens (40 x 10 x 3.3 mm) were evaluated (n=2) by dynamical-mechanical thermal analysis (DMTA) under different temperature ranges (runs). Values of storage modulus (E’) and loss tangent (tan δ) at 37ºC were obtained from the first and last runs. The glass transition temperature (Tg) was only measured from the last run. Ultimate flexural strength (UFS - MPa) and flexural strength at the proportional limit (FSPL - MPa) were determined (n=10) by three-point test (0.5 mm/min) using intact and relined specimens (64 x 10 x 3.3 mm). To evaluate the SBS between the materials, 60 cylinders (20 x 20 mm) of the denture base resin L were processed, relined (3.5 x 5.0 mm) and submitted to shear testing (0.5 mm/min). Data were analyzed by ANOVA and Tukey... (Complete abstract click electronic access below)
178

Efeito do envelhecimento acelerado sobre a microdureza superficial, rugosidade e opacidade de resinas acrílicas incolores termopolimerizáveis e calotas oculares empregadas em prótese ocular, em função da espessura

Fernandes, Aline Úrsula Rocha [UNESP] 12 December 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-12-12Bitstream added on 2014-06-13T20:25:52Z : No. of bitstreams: 1 fernandes_aur_dr_araca.pdf: 3876257 bytes, checksum: 0b3f599e97b9e9ee18afc401d2068c8c (MD5) / As próteses oculares são responsáveis pelo restabelecimento da estética, harmonia facial e auto-estima do paciente anoftálmico. Confeccionados em resina acrílica, os olhos artificiais devem ser estéticos, perfeitamente polidos e resistentes a riscos, características que, quando não satisfeitas, podem gerar transtornos psicológicos, possíveis infecções ou inflamações originárias de substâncias e organismos depositados nas irregularidades superficiais da prótese. O propósito do estudo foi avaliar a microdureza e rugosidade superficiais e opacidade de calotas incolores próprias para prótese ocular e de três marcas de resina acrílica incolor termopolimerizável por banho de água quente de curta e média duração e duas por energia de microondas, em função do envelhecimento acelerado (1008 horas) e espessura (1 e 3,5 mm). Para o estudo, foram obtidas 120 amostras, distribuídas em 12 grupos (n= 10). A análise foi realizada por meio de microdurômetro (Shimadzu Corp., Kyoto, Japão), rugosímetro (TONKA Sul Americana Ltda., SP, Brasil) e espectrofotômetro de reflexão (Shimadzu Corp., Kyoto, Japão). Os valores obtidos antes e após envelhecimento acelerado foram analisados estatisticamente pela Análise de Variância de três fatores e pelo teste de Tukey a 1% de significância. Para o teste de microdureza, as calotas oculares e a resina QC 20 apresentaram, respectivamente, os maiores e menores valores de microdureza superficial, independente da variável avaliada; a espessura não influenciou a propriedade estudada e as amostras apresentaram valores médios de microdureza superficial maiores após o envelhecimento acelerado. / Artificial eyes are responsible for reestablishing the facial esthetics, harmony and self esteem of the anophthalmic patient. Made of acrylic resin, artificial eyes must be esthetic, perfectly polished and scratchresistant characteristics which, when not satisfied, may cause psychological disturbances, possible infections or inflammations originating from substances and organisms deposited on the surface irregularities of the prosthesis. The aim of this study was to assess the microhardness, surface roughness and opacity of colorless ocular button for the purpose of use in artificial eyes, and three brands of colorless acrylic resin heat-polymerizable by hot water bath of short and medium duration and two by microwave energy, as a function of accelerated aging (1008 hours) and thickness (1 and 3.5 mm). For this study, 120 samples were obtained, distributed into 12 groups (n=10). Analysis was performed by means of microhardness meter (Shimadzu Corp., Kyoto, Japan), rugosity meter (TONKA Sul Americana Ltda., SP, Brazil) and reflection spectrophotometer (Shimadzu Corp., Kyoto, Japan). The values obtained before and after accelerated aging were statistically analyzed by Analysis of Variance for 3 factors and the Tukey test at 1% significance. For the microhardness test, the ocular buttons and QC 20 resin respectively presented the highest and lowest surface microhardness values, irrespective of the variable assessed; the thickness had no influence on the studied property, and the samples presented higher mean surface microhardness values after accelerated aging. For the roughness test, there was no statistically significant difference with regard to accelerated aging; the resin Vipi Cril, at the thickness of 3.5 mm and ocular button at the thickness of 1 mm presented the lowest roughness value.
179

Análise da variação da posição dos dentes artificiais durante as fases específicas do processamento de próteses totais superiores mensurada por computação gráfica

Shibayama, Ricardo [UNESP] 23 March 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-03-23Bitstream added on 2014-06-13T19:24:19Z : No. of bitstreams: 1 shibayama_r_dr_araca.pdf: 1447114 bytes, checksum: 3c09de09a6fe8d140870e923ba0cd69a (MD5) / Foi investigada a alteração da posição dos dentes artificiais durante o processamento de próteses totais desde a fase de enceramento até o polimento, utilizando as resinas de marcas comerciais QC 20 (Dentsply) e Onda Cryl (Clássico - específico para microondas), com inclusão em gesso tipo II e com muralha de silicone, polimerizadas tanto pelo método de banho em água quente, quanto pela polimerização por energia de microondas. Foram utilizadas 40 amostras, obtidas de um modelo padrão e divididas em 4 grupos de 10, que receberam os seguintes tipos de processamento. a) grupo 1: incluídos em muflas metálicas com muralha de gesso pedra e polimerização por banho de água quente. b) grupo 2: incluídos em muflas de fibra de vidro com muralha de gesso pedra e polimerização por microondas. c) grupo 3: incluídos em muflas metálicas com muralha de silicone e polimerização por banho em água quente. d) grupo 4: incluídos em muflas de fibra de vidro com muralha de silicone e polimerização por energia de microondas. Para detecção dos deslocamentos dentais utilizou-se um guia de resina acrílica com 5 pontos pré-determinados nas cúspides dos dentes que proporcionaram pontos de referência nas réplicas permitindo mensurar tais deslocamentos através da digitalização das superfícies oclusais dos dentes e analisados por um programa de computador AutoCad. Baseados nos resultados obtidos, de acordo com os materiais e metodologia empregados, concluimos que: 1. Em todas as técnicas de processamento de prótese total estudadas houve alteração da posição dos dentes após o processamento. 2. A técnica de inclusão com muralha de silicone e polimerização por microondas (grupo 4) apresentou os menores valores de alterações na posição dos dentes durante toda a fase de processamento... / Artificial teeth position changes were investigated during the upper complete denture processing, resins QC 20 (Dentsply) and Onda Cryl (Clássico - specific for microwave energy) were used and flasked in type II gypsum stone mould or silicone mould, polymerized in hot water bath as well in microwave polymerization. Forty specimens were used, which were obtained from one standard cast, and divided into four groups of ten that were processed as the following: a) group I (control): flasked in metallic muffles with gypsum stone barrier and conventional polymerization. b) group II: flasked in glass fiber muffles with gypsum stone barrier and polymerization by microwave energy. c) group III: flasked in metallic muffles with silicone barrier and conventional polymerization. d) group IV: flasked in glass fiber muffles with silicone barrier and microwave polymerization. An acrylic resin guide was used to detect teeth displacements, this guide was marked with 5 predetermined points in teeth cuspids that has proportionate reference points in the replicas. These points were used to measure, by AutoCad software, teeth displacements by digitized occlusal surface of the teeth. Based upon the results, according to the employed material and method, the following can be concluded: 1. It was observed teeth position changes after denture processing in all experimental groups. 2. The technique of flasking with silicone mould and microwave polymerization (group 4) presented minor degree of teeth position changes during all the processing. 3. The segments that constitute the smaller triangle represented by the points of teeth 15, 21 and 25 showed more homogeneity and linearity than the bigger triangle represented by the cuspids of 17, 21 and 27. 4. These dimensional changes of shrinkage and expansion in both triangles followed a uniform sequence for all the segments, that is, as one segment changes, the others follow it, thus, they don t occur randomly.
180

Influência da rugosidade de superfície e ação de diferentes desinfetantes na formação de biofilme em resina acrílica para prótese ocular e sua biocompatibilidade em contato com células da conjuntiva humana / Influence of surface roughness and action of different disinfectants on the formation of biofilm in acrylic resin for ocular prosthesis and their biocompatibility in contact with cells human conjunctiva cells

Andreotti, Agda Marobo [UNESP] 31 August 2017 (has links)
Submitted by Agda Marobo Andreotti (36897500836) on 2017-10-19T21:29:31Z No. of bitstreams: 1 TESE DOUTORADO AGDA MAROBO ANDREOTTI.pdf: 5621947 bytes, checksum: ad2de971e6e9dcd6b35700dd4f7bc0d1 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-10-23T18:36:23Z (GMT) No. of bitstreams: 1 andreotti_am_dr_araca.pdf: 5621947 bytes, checksum: ad2de971e6e9dcd6b35700dd4f7bc0d1 (MD5) / Made available in DSpace on 2017-10-23T18:36:23Z (GMT). No. of bitstreams: 1 andreotti_am_dr_araca.pdf: 5621947 bytes, checksum: ad2de971e6e9dcd6b35700dd4f7bc0d1 (MD5) Previous issue date: 2017-08-31 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O controle da formação de biofilme é essencial para manter a saúde da cavidade anoftálmica dos portadores de prótese ocular. As propriedades físicas da resina acrílica, como a sua rugosidade, podem interferir na adesão de microrganismos nas próteses e na formação de biofilmes. Sendo assim, é necessário utilizar soluções de limpeza eficazes e que não causem irritação tecidual na conjuntiva ocular. O objetivo desse trabalho foi verificar a influência da rugosidade de superfície da resina acrílica utilizada na confecção de próteses oculares na formação de biofilme bacteriano, bem como avaliar a eficácia antimicrobiana e citotoxicidade de diferentes soluções para desinfecção de próteses oculares. Para a análise da rugosidade, corpos de prova de resina acrílica foram confeccionados e divididos em 5 grupos de acordo com a granulação de lixa de polimento utilizada: 120, 400, 800, 1200 e 1200S (lixa + sílica). A rugosidade dos corpos de prova foi mensurada por meio de perfilômetro e imagens de Microscopia de Força Atômica foram obtidas para cada grupo. O crescimento das espécies Staphylococcus aureus e Staphylococcus epidermidis sobre os corpos de prova foi avaliado após 4 e 24h, por meio da contagem das Unidades Formadoras de Colônia (UFC)/mL. O efeito dos seguintes tratamentos: soro fisiológico, sabão neutro, clorexidina 4%, pastilhas efervescentes Efferdent®, triclosan 1% e citronela sobre biofilme formado sobre os corpos de prova de resina acrílica também foi avaliado por meio da determinação do número de UFC/mL. A citotoxicidade dos agentes antimicrobianos foi avaliada por meio dos testes de MTT e Neutral Red, após tratamento dos corpos de prova, diariamente, por 1, 7, 15, 30, 60 e 90 dias com as soluções já citadas, sendo avaliados ao fim de cada período. Os dados obtidos foram submetidos à análise estatística adequada, considerando se provinham de dados paramétricos ou não paramétricos. Os resultados demonstraram que os menores valores de rugosidade foram encontrados no grupo 800, 1200 e 1200S. A contagem microbiana foi menor no grupo 1200S e esta diferiu estatisticamente (p>0,05) do controle para ambos os tempos de avaliação e bactérias. Na análise da ação antimicrobiana das soluções para desinfecção, todos os protocolos promoveram redução do crescimento dos microrganismos testados comparados ao controle (crescimento sem a presença do antimicrobiano), sendo que os grupos submetidos ao tratamento com clorexidina 4%, pastilhas efervescentes Efferdent® e triclosan 1% eliminaram o biofilme (p>0,01). Ainda nos ensaios de citotoxicidade, em todos os grupos foi observada proliferação celular das células da conjuntiva acima de 84% (p>0,05). Dessa forma, conclui-se que a rugosidade não interfere significativamente na adesão bacteriana e formação de biofilme, exceto para o grupo 1200S, e que os protocolos de limpeza com imersão em clorexidina 4%, pastilhas efervescentes Efferdent® e triclosan 1% são totalmente eficazes na desinfecção e não apresentam citotoxicidade para com as células da conjuntiva humana, sugerindo sua indicação para desinfecção de próteses oculares. / The control of biofilm formation is essential to maintain the health of anophthalmic cavity of ocular prosthesis wearers. The physical properties of the acrylic resin, such as surface roughness, may interfere with the adhesion of microorganisms to the prostheses. Therefore, it is necessary to use cleaning solutions that are effective and do not cause tissue irritation in ocular conjunctiva. The aim of this study was to verify the influence of surface roughness of the acrylic resin used in the preparation of ocular prosthesis in the formation of bacterial biofilm, as well as to evaluate the antimicrobial efficacy and cytotoxicity of different disinfectants in ocular prostheses. For roughness analysis, acrylic resin samples were prepared and divided into 5 groups according to the granulation of polishing sandpaper used: 120, 400, 800, 1200 and 1200S (sandpaper + silica). The roughness of the samples was measured using a profilometer and Atomic Force Microscopy images were obtained for each group. The microbial growth for Staphylococcus aureus and Staphylococcus epidermidis on the samples was evaluated after 4 and 24 h by counting the Colony Forming Units (CFU)/mL. The effect of the following solutions was also evaluated by CFU/mL: non treated group (immersed in saline solution), neutral soap, 4% chlorhexidine, Efferdent® effervescent tablets, 1% triclosan and citronella. The cytotoxicity of the solutions was evaluated by MTT and Neutral Red after treating the samples daily for 1, 7, 15, 30, 60 and 90 days with the solutions already mentioned, being evaluated at the end of each period. Data were submitted to proper statistical analysis, considering whether data were parametric or non-parametric. The results showed that the lowest roughness values were found in groups 800, 1200 and 1200S. 1200S group also presented the lowest values of microbial growth statistically different from control group (p>0,05), for both periods and bacteria evaluated. In the analysis of the solutions, compared to the control group (microbial growth without the presence of the antimicrobial), all protocols promoted a reduction in the growth of the microorganisms, and the groups submitted to disinfection with 4% chlorhexidine, Efferdent® effervescent tablets and 1% triclosan eliminated the biofilm (p>0,01). In addition, all groups showed cell proliferation of conjunctival cells above 84% in the cytotoxicity assays (p>0,05). Thus, it was concluded that the roughness does not significantly interfere in the adhesion of the microorganisms, except for group 1200S, and that the cleaning protocols with 4% chlorhexidine, Efferdent® effervescent tablets and 1% triclosan are totally effective in the disinfection and do not present cytoxicitiy with human conjunctive cells, what suggests their indication for cleaning of ocular prosthesis. / CNPq: 141722/2015-0

Page generated in 0.0616 seconds