• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 913
  • 33
  • 13
  • 13
  • 13
  • 13
  • 12
  • 8
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 968
  • 600
  • 138
  • 138
  • 108
  • 105
  • 87
  • 86
  • 80
  • 72
  • 68
  • 67
  • 63
  • 58
  • 53
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Controle adaptativo de interferência multiusuário em redes IR-UWB

BEZERRA, Átila Medeiros 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T15:50:51Z (GMT). No. of bitstreams: 1 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / A tecnologia UWB (Ultra-WideBand) é uma das mais promissoras para a comunicação em redes sem fio de curto alcance. Esta afirmação é reforçada pelo fato dos sinais UWB ultrapassarem facilmente obstáculos e pelo fato da tecnologia permitir uma banda passante ultra-larga associada a um baixo consumo de energia. As interferências multi-usuário (MUI) em redes UWB são um dos principais fatores que contribuem para uma degradação rápida da qualidade da comunicação na rede. Assim sendo, a adoção de um mecanismo de mitigação de interferências multi-usuário se faz necessário. Esta dissertação propõe um método de mitigação adaptativa de MUI para redes UWB TH-PPM (Time Hopping - Pulse Position Modulation). O método proposto, chamado de MSS-UWB, se baseia nos sistemas de múltiplos códigos com o objetivo de criar vários enlaces entre um mesmo par transmissor-receptor e realizar adaptação da taxa de dados através da seleção adaptativa destes enlaces. Simulações realizadas com o auxílio do Matlab demonstraram que a utilização de múltiplas seqüências TH para a mitigação adaptativa da MUI traz benefícios com relação à utilização do canal de comunicação.
162

SIGnUs: arquitetura para configuração e adaptação de sistemas de informações geográficas ubíquos

FRANÇA, Sônia Virginia Alves 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T15:50:57Z (GMT). No. of bitstreams: 2 arquivo1993_1.pdf: 2432405 bytes, checksum: 0ec709e23b4bd4d0b4e6ac5c50b33353 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / Os Sistemas de Informações Geográficas (SIG) são ferramentas para manipulação e análise de dados geográficos e são adotados extensamente para auxiliar no planejamento urbano, agricultura, transporte, energia e muitos outros campos. Os SIG evoluíram acompanhando os avanços tecnológicos e as necessidades dos seus usuários, e assim tornaram-se móveis. Para o desenvolvimento de SIG móveis, duas arquiteturas se sobressaem, e estas apresentam limitações que podem dificultar o seu uso em determinadas situações. Na primeira, o SIG é formado por um conjunto restrito de operações e a aplicação é completamente instalada no dispositivo móvel. Por se tratar de um dispositivo com limitações, este SIG terá um conjunto de operações reduzido, podendo não atender, efetivamente, às necessidades do usuário. Na segunda abordagem, o SIG é acessado, geralmente, através de um Internet browser. Apesar de ter acesso a um conjunto maior de operações, é necessária uma boa qualidade de comunicação, o que nem sempre ocorre em ambientes remotos. Caso contrário, o SIG ficará inacessível. Este trabalho avança, portanto, propondo uma arquitetura para SIG móveis - Arquitetura SIGnUs - baseada em computação sensível ao contexto e componentes. A arquitetura SIGnUs tem o intuito de minimizar as restrições encontradas nas arquiteturas SIG móveis atuais (pequeno e prédefinido conjunto de operações geográficas ou dependência de rede), buscando um uso mais efetivo destas aplicações. A arquitetura SIGnUs é composta por uma Ferramenta de Configuração que possibilita a geração de um SIG Móvel Adaptado, através da interpretação de informações contextuais, e um conjunto de serviços de middleware que dará suporte à geração do SIG. Utilizando a ferramenta SIGnUs, o usuário recebe sugestões baseadas em contexto durante a configuração do seu SIG móvel, com as operações geográficas necessárias para a apropriada execução de suas tarefas, e que possa ser instalado no seu dispositivo móvel (notebook ou PDA, por exemplo). Assim, tem-se um SIG móvel que reúne as vantagens de se ter um conjunto de operações que varia de acordo com a necessidade do usuário e independência de rede
163

Uma arquitetura de computação pervasiva para trabalho de campo

Johnson, Thienne de Melo e Silva January 2005 (has links)
Made available in DSpace on 2014-06-12T15:54:27Z (GMT). No. of bitstreams: 2 arquivo7150_1.pdf: 2045255 bytes, checksum: 976ef7e84c4dd4ecc1bcdf4c41dc99f7 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2005 / Os ambientes de trabalho de campo possuem diversas restrições, como falta de infraestrutura e dispositivos de baixa capacidade. Trabalhos atuais sobre redes ad hoc e computação pervasiva deixam de considerar diversos aspectos que poderiam melhorar os ambientes de campo. Este trabalho de tese descreve uma arquitetura composta de serviços e um protocolo projetados para dar suporte aos requisitos do trabalho de campo. Os serviços foram projetados para dar suporte aos diversos tipos de dispositivos, com diversos padrões de mobilidade. Os dados de roteamento dentro da área de trabalho consideram aspectos dos tipos dos dispositivos, indicando ao serviço de adaptação de conteúdo os tipos de nós do ambiente. O uso de uma estratégia de atualização de informações de localização física também reduz a carga de dados que é transmitida no ambiente. Também é apresentado um protocolo de roteamento que usa informações de localização física de diversas formas. Essas informações podem gerar sub-áreas de trabalho, limitando o escopo das mensagens que trafegam na rede, sendo utilizadas apenas pelos trabalhadores de uma área. Também permitem a troca de dados entre diferentes locais, através do uso de nós que controlam a borda das áreas de trabalho. O conhecimento dos nós vizinhos permite o roteamento por localização e a troca de informações somente entre os nós próximos. Estas contribuições podem também ser utilizadas por outros sistemas de computação pervasiva que tenham interesse em melhorar seu desempenho
164

MAPS : um modelo de adaptação de processos de software

COELHO, Ciro Carneiro January 2003 (has links)
Made available in DSpace on 2014-06-12T15:58:44Z (GMT). No. of bitstreams: 2 arquivo4682_1.pdf: 626196 bytes, checksum: 1fb1dc5d0a7cd2ad5b76df6668bf1f92 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2003 / Como conseqüência do aumento da complexidade dos softwares e das maiores exigências do mercado, a busca de processos que venham organizar e melhorar o desenvolvimento de software tem crescido nos últimos anos. Apesar do grande número de processos disponíveis atualmente, não existe um processo de software único que se adeqüe a todas as situações. A eficiência de um processo varia de organização para organização e até entre os diferentes projetos de uma mesma organização. Uma solução comumente adotada é a definição de um processo padrão para a organização, em conjunto com diretrizes e critérios para a adaptação desse processo. A definição das diretrizes e dos critérios de adaptação é uma tarefa não-trivial, e vem sendo abordada de várias formas diferentes dentro da comunidade de Engenharia de Software. Este trabalho apresenta o Modelo de Adaptação de Processos de Software - MAPS, um modelo compatível com o Capability Maturity Model CMM, e que auxilia a adaptação de um processo padrão para projetos específicos e promove o reuso e melhoria de processos de software. O MAPS é constituído por três componentes principais. A Base de Processos armazena o conhecimento adquirido sobre a utilização de processos em projetos passados. O Modelo de Caracterização de Projetos realiza uma comparação de projetos de software, permitindo identificar projetos semelhantes e facilitando, assim, o reuso de processos. O PConfig é responsável por configurar o processo padrão para projetos específicos com base nos artefatos do processo padrão. O MAPS objetiva a criação de uma base de processos adaptados, todos gerados a partir do processo padrão e adaptados às características específicas dos projetos, definindo, também, como esses processos adaptados podem ser reusados em projetos futuros de acordo com as características dos projetos. Para avaliar o MAPS, foi realizado um estudo de caso comparando os processos utilizados em dois projetos reais com os processos sugeridos pelo MAPS
165

UMA PROPOSTA DE ENSINO BASEADO NA ABORDAGEM CLIL: APROPRIAÇÕES DE UMA PROFESSORA/PESQUISADORA

NEGOCEKI, E. B. 16 July 2018 (has links)
Made available in DSpace on 2018-09-21T14:10:12Z (GMT). No. of bitstreams: 1 tese_12587_TEXTO FINAL COMPLETO - Edineia print version.pdf: 9557215 bytes, checksum: 0fdb61017e4dbe2309b454c1affdb50f (MD5) Previous issue date: 2018-07-16 / Este trabalho analisa possibilidades e limitações da abordagem de ensino de conteúdos diversos por meio da língua conhecida como Content and Language Integrated Learning ou CLIL na abreviação em inglês e doravante, no ensino de inglês da Educação Infantil. As perguntas de pesquisa que norteiam o trabalho são quais são possibilidades e limitações do uso da abordagem CLIL na educação infantil e quais são apropriações de uma professora/pesquisadora dessa abordagem para selecionar, elaborar, adaptar, implementar e avaliar atividades baseadas na abordagem CLIL. A metodologia de pesquisa é a da pesquisa-ação e o estudo foi realizado em uma escola privada regular não-bilíngue com crianças de 5 e 6 anos de idade, falantes apenas de português como língua materna (L1), em 3 turmas no último ano da Educação Infantil, totalizando 54 participantes. Foram preparados 10 planos de aula com base na abordagem CLIL para trabalhar conteúdos de Matemática, Linguagem Oral e Escrita e Ciências da Natureza ministrados em inglês como língua estrangeira (L2) para esse público. O arcabouço teórico que fundamenta a pesquisa é o da teoria sociocultural de Vigotsky (1934), com foco no conceito de Zona de Desenvolvimento Proximal (ZDP) proposto por ele. Os dados da pesquisa incluem notas do diário da professora/pesquisadora e os planos de aula produzidos e adaptados por ela. A análise dos dados mostra que é possível a utilização da abordagem CLIL na Educação Infantil por meio da mediação do professor, com a ajuda de materiais concretos que se relacionem com o conhecimento prévio dos alunos. O estudo conclui que existem possibilidades de uso da abordagem CLIL na Educação Infantil desde que as limitações relacionadas à formação de professores para atuarem com essa abordagem sejam superadas.
166

Efeito da ciclagem mecânica, material e retorque de parafusos, na estabilidade de próteses múltiplas sobre implantes com dois níveis de desajuste / Effect of mechanical cycling, material and retorque screws, in stability of complete implant-suported prosthesis with two fit levels

Farina, Ana Paula 03 January 2011 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T03:20:12Z (GMT). No. of bitstreams: 1 Farina_AnaPaula_D.pdf: 1605705 bytes, checksum: 829e909eecce5995165949e1b708c7d8 (MD5) Previous issue date: 2011 / Resumo: O afrouxamento dos parafusos protéticos é frequentemente encontrado nos exames de rotina e pode causar complicações. Assim, métodos para sua prevenção devem ser desenvolvidos. O objetivo neste estudo foi avaliar a influência do retorque de parafusos protéticos (titânio ou ouro) na estabilidade de próteses totais implantossuportadas com diferentes níveis de adaptação (passiva ou desadaptada), após simulação da função mastigatória por meio de ciclagem mecânica (6 meses, torque de afrouxamento, reaperto dos parafusos + 6 meses de simulação; ou 1 ano de simulação e torque de afrouxamento). No capítulo 1, 10 próteses mandibulares implantossuportadas e 20 modelos foram confeccionados para duas condições de adaptação: passiva (adaptada) e não-passiva (desadaptada). Também foram avaliadas duas técnicas de aperto em função da aplicação de retorque e materiais do parafuso: 1) sem retorque + parafusos de titânio; 2) sem retorque + parafusos de ouro; 3) com retorque + parafusos de titânio; e, 4) com retorque + parafusos de ouro. Para a técnica de aplicação de retorque, os parafusos foram apertados (10 Ncm) e após 10 minutos, reapertados (10 Ncm). O torque de afrouxamento dos parafusos foi mensurado por meio de torquímetro digital de precisão após simulação de 1 ano da função mastigatória. Os dados foram submetidos à análise de variância (ANOVA) em 2 fatores seguido pelo teste complementar de Tukey em (?=0,05). Os fatores adaptação e técnica de aperto (retorque e tipo de parafuso), e a interação entre os fatores foram estatisticamente significantes. O desajuste diminui o torque de afrouxamento. A aplicação do retorque aumentou a estabilidade da conexão dos parafusos, independente da adaptação ou material dos parafusos. No capítulo 2, próteses passivas e não-passivas foram fabricadas de modo semelhante ao capítulo 1. O torque de afrouxamento foi mensurado após 2 condições de simulação de uso clínico: 1) 6 meses / torque de afrouxamento / reaperto / mais 6 meses / torque de afrouxamento; 2) 1 ano de simulação / torque de afrouxamento. Foram utilizados parafusos de titânio e ouro. O teste estatístico foi similar ao capítulo 1. O fator tempo de ciclagem e condição de uso (nível de ajuste e tipo de parafuso), bem como a interação desses fatores influenciaram os valores de torque de afrouxamento (p<0,05). Após 6 meses + 6 meses de simulação de uso clínico, os parafusos de titânio apresentaram maiores valores de torque de afrouxamento quando comparados aos parafusos de ouro, para o mesmo nível de adaptação. Após 1 ano de simulação de uso clínico, ambos materiais dos parafusos em próteses passivas apresentaram valores mais elevados que em próteses não-passivas. Dessa forma podemos concluir que a desadaptação reduz o torque de afrouxamento dos parafusos e que o retorque após 10 minutos consegue estabilizá-los. Parafusos de titânio apresentaram maior estabilidade que parafusos de ouro após 6 meses de simulação devido a sua menor deformação plástica. Quando o tempo de ciclagem foi analisado, parafusos de titânio apresentaram menor estabilidade após 1 ano de simulação devido à perda de torque frente à desadaptação, necessitando acompanhamento mais criterioso para que mantenham sua estabilidade / Abstract: The prosthesis screw loosening is often found at routine examinations and may cause complications. Therefore, methods to prevent them must be developed. The objective of this study was to evaluate the influence of retorque application on joint stability of prosthetic screws (titanium or gold) in implant-supported dentures under different fit levels (passive or misfit), after masticatory function simulated by means of mechanical cycling (6 months, loosening torque, screws retightening and another 6 months of simulation; or 1 year of simulation). In the first chapter, 10 mandibular implant-supported dentures and 20 cast models were fabricated to two fit levels: passive fit and misfit. Two tightening techniques were also evaluated according to the retorque application and screws material: 1) without retorque + titanium screws; 2) without retorque + gold screws; 3) retorque + titanium screws; and 4) retorque + gold screws. The screws were tightened 10 Ncm and retightened to 10 Ncm after 10 min. The screw joint stability was measured after a one-year clinical function simulation using a digital torque meter. Data were analyzed statistically by ANOVA/Tukey's test (?=0.05). The factors of fit level and tightening technique and the interaction between the factors were statistically significant. The misfit decreases the loosening torque. The retorque application increased joint stability independent of fit level or screw material. In the chapter 2, passive and misfit dentures were fabricated as in chapter 1. The loosening torque was measured after two conditions of clinical use simulating: six months / torque loosening / retightening / further six months / loosening torque; and one year of simulation / loosening torque. Titanium and gold screws were used. The statistical analysis was similar to the first chapter. Therefore, the factor cycling time and condition use (fit level and screw type) as well the interaction between the factors influenced the loosening torque values (p<0.05). After six months another six months of masticatory function simulated, the titanium screws showed higher loosening torque than did gold screws for the same fit level. After one year of clinical use simulation, both material screws in passive dentures showed higher loosening torque values than did misfit dentures. Thus we can conclude that the misfit decreases the loosening torque and retorque application increased joint stability. The stability of titanium screws was higher than gold screws after 6 months of simulation, due to its lower plastic deformation. When the cycling time was analyzed, titanium screws were less stable after 1 year of simulation due to loss of torque in misfit presence, requiring more careful monitoring to maintain stability / Doutorado / Protese Dental / Doutor em Clínica Odontológica
167

Respostas cardiorrespiratorias ao exercicio fisico dinamico e função autonomica em primigestas

Baciuk, Erica Passos 18 February 2000 (has links)
Orientadores: Luiz Eduardo Barreto Martins, Hugo Sabatino / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-07-26T16:25:34Z (GMT). No. of bitstreams: 1 Baciuk_EricaPassos_M.pdf: 1870398 bytes, checksum: 595b02f2adb0af2796a108894d699ca5 (MD5) Previous issue date: 2000 / Resumo: Este trabalho tem por objetivos avaliar a capacidade funcional cardiorrespiratória ao exercício fisico dinâmico, e estudar a função autonômica cardiovascular em primigestas durante os períodos que compreendem o 2° e o 3° trimestres gestacionais. Para avaliação da capacidade funcional cardiorrespiratória foi realizado um protocolo contínuo de esforço em cic1oergômetro (pC - rampa de 10 watts/minuto) até a exaustão fisica, com registro contínuo da freqüência cardíaca materna (PC), pressão arterial (P A), produção de dióxido de carbono (v co 2)' consumo de oxigênio (-ir 02 ), ventilação ( v ), volume corrente (VC), fteqüência respiratória (FR), temperatura corporal e fteqüência cardíaca fetal (PCF) no repouso e no exercício. A resposta autonômica cardiovascular foi estudada por meio da avaliação do comportamento da fteqüência cardíaca (PC) e da pressão arterial (P A) materna durante as Manobras Postural Passiva (MPP) e Manobras de Valsalva nas posições supina e cócoras. Constatou-se, em repouso, maiores valores de ventilação, volume corrente e pressão arterial sistólica (p<O,O5) e, menores valores de FCF na posição supina para o grupo do 3° trimestre gestacional quando comparados ao grupo do 2° trimestre. Quanto ao comportamento das variáveis estudadas no exercício, observou-se maiores valores do v CO 2 pico e da ventilação para o grupo do 3° trimestre gestacional (p<O,O5), não foram encontradas diferenças estatísticas para as variáveis -ir 02, volume corrente, fteqüência respiratória e fteqüência cardíaca entre os grupos estudados. Os valores de pressão arterial sistólica apresentaram elevação em ambos os grupos estudados, sendo maior para o grupo do 3° trimestre (p<O,OS), entretanto a pressão arterial diastólica não se modificou. O grupo do 3° trimestre atingiu maiores valores de potência de esforço tanto no limiar de anaerobiose (LA) como no pico do esforço (p<O,OS). No início da recuperação, este grupo apresentou maior aumento da temperatura corporal. A FCF apresentou aumento, quinze minutos após o término do esforço materno no 3° trimestre gestacional. Com relação à MPP, observou-se aumento da FC materna e diminuição inicial da pressão arterial sistólica, em ambos os grupos estudados. Na manobra de Valsalva observou-se menor variação da resposta da FC materna para o grupo do 3° trimestre gestacional, sendo ainda menor na posição de cócoras. Os valores de pressão arterial sistólica se elevaram no grupo do 3° trimestre, em ambas posições, retomando aos valores de repouso durante a recuperação somente na posição de cócoras. A pressão arterial diastólica não se modificou. Com estes resultados concluiu-se que Gestantes no 3° trimestre têm maior metabolismo basal, sugerido pelos valores aumentados nas variáveis ventilatórias de repouso. Os resultados obtidos no esforço fisico sugerem que a gravidez mais avançada pode apresentar fatores condicionantes da capacidade fisica da gestante / Abstract: The aim of this study was to quantify the cardiorrespiratory functional capacity during the dynamic physical exerci se and to evaluate the cardiovascular autonomic function in primigravidas in the second and third trimester. To evaluate the cardiorrespiratory functional capacity it was conducted an exerci se test (continuous protocol) up to physical exhaustion, using a cycloergometer (ramp function - 10 watts/min). We continuously monitored the maternal heart rate (HR), the arterial blood pressure (BP), the C02 production (v co ,), 02 consumption (v 02), the ventilation (v), the tidal volume (VT), the respiratory rate (t), the body temperature and fetal heart rate (FHR), during rest and exercise condition. The autonomic cardiovascular function was achieved by studying the maternal HR. and BP responses during the Head-Up Tilt (HUT) and Valsalva Maneuver (VM). Comparing the 2M and 3m gestation trimester groups, in the last the values of ventilation, tidal volume and arterial blood pressure were higher (p<0.05) and the FHR values at supine position was lower. Considering the cardiorrespiratory variables during exercise, the peak v co, at the ventilation were higher for the 3m gestation trimester (p<0.05) and the v 02, the tidal volume (VT), the respiratory rate, and HR. was not statisticaIly significant comparing the groups (2M and 3m gestation trimester). The systolic arterial pressure increase was higher for the 3m gestation trimester (p<0.05), but the diastolic arterial pressure didn't change during the exerci se for both groups. The 3m gestation trimester group presented higher values of workload at anaerobic threshold (AT) and peak exercise conditions (p<0.05). At the beginning of the recovery phase, the body temperature was higher for this group. The FHR increased 15 minutes after the end of exerci se in this same group. During the HUT the maternal HR increased and the systolic arterial pressure decreased in the beginning of the test in both groups. In the VM the maternal HR changes was lower for the 3r4 gestation trimester group and was even smaller in the squat position. The systolic arterial pressure values increased for the 3r4 gestation trimester group, at supine and squat positions, and returned to baseline values during the recovery on1y in the squat position. The diastolic arterial pressure didn't change. These results suggest that the pregnant women during the 3r4 gestation trimester have lower basal metabolism, showed by the higher values of the ventilatory variables during rest condition, and that in the more advanced pregnancy could exist conditioning factors that determine the physical capacity of the preêlant / Mestrado / Mestre em Educação Física
168

Influência das temperaturas de cocção de porcelanas no desajuste cervical de copings em titânio comercialmente puro e ligas titânio-alumínio-vanádio e paládio-prata

Fonseca, Johnson Campideli 28 July 2018 (has links)
Orientador : Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T00:39:18Z (GMT). No. of bitstreams: 1 Fonseca_JohnsonCampideli_M.pdf: 12216850 bytes, checksum: 6238e2e5911c70a5790792f791e70d48 (MD5) Previous issue date: 2001 / Resumo: A utilização do titânio e suas ligas em prótese tem aumentado nos últimos anos do conjunto de propriedades físico-químicas que exibem, sendo escassas as >rmaçôes a respeito da adaptação cervical de restaurações fundidas. Este estudo objetivou: 1) determinar o desajuste cervical de copings fundidos em comercialmente puro (Ti c.p.) e iigas titánio-aiumínio-vanádio (ÏÎ-6AI-4V) e paládio-prata (Pd-Ag); 2) avaliar a influência do ciclo de cocção das porcelanas preconizadas sobre o desajuste cervical dos copings fundidos em Ti c.p. e ligas TÍ-6A1-4V e Pd-Ag; 3) avaliar a aneíusão) sobre o desajuste cervical dos copings fundidos em Ti c.p. e bga TÏ-6A1-4V. s típicos para restaurações as {altura de 5mm; término cervical em ombro 90° e largura de l,5mm; erimentais Ti-óAMV, TÍ-6A1-4V com tratamento térmico (TÍ-6A1-4V TT), Ti c.p.. Ti érmico (Ti c.p. TT) e Pd-Ag. Os copings em Ti c.p. e liga TÍ-6A1-4V pelo sistema Rematitan (Dcntaurum). O tratamento térmico experimental s TÍ-6A3-4V TT e Ti c.p. TT) foi realizado nas inclusões originais à temperatura do aquecimento da porcelana (800°C). O desajuste cervical tbi medido com auxilio metidos à Análise de Variância (ANOVA) e teste de Tukey, com nível de probabilidade 5%. Os valores médios de desajuste cervical obtidos ao final dos ciclos de cocção 78um para TÍ-6A1-4V, 86,02 urn para TÍ-6A1-4V TT, 117,22um para Ti c.p., para Ti c.p. TT e 9S,70um para Pd-Ag, sem que houvesse diferença significativa entre tais valores. O desajuste cervical dos grupos m Ti c.p. e TÍ-6AÍ-4V não foi influenciado de forma significante pelo ciclo de cocção da porcelana Vitatitankramic. O grupo Pd-Ag mostrou alternação estatisticamente significativa apos a cocção da porcelana para dentina e glaze / Abstract: The application of titanium and titanium alloys in prosthetic dentistry has increased in the past few years because of their physical and chemical properties; however, few studies have investigated the marginal fit of cast restorations. This study evaluated: 1) the marginal fit of copings obtained in commercially pure titanium (c.p. Ti), thanium-aluminurn-vanadiurn (Ti-6A1-4V) and palladium-silver (Pd-Ag) alloys; 2) the influence of firing cycle of recommended porcelains in the marginal fit of c.p. Ti, Ti-6A1-4V and Pd-Ag alloys; 3) the effectiveness of additional heating at the first temperature of firing cycle in the marginal fit of Ti c.p. and Ti-6A1-4V copings. Fifty bovine teeth with standardized preparations for metal-ceramic crowns (length of 5mm; axial taper of 8°; shoulder of 1,5mm) were used and divided in T1-6A1-4V, Ti-6A1-4V with additional heat (Ti-6A1-4V TT), Ti c.p., Ti c.p. with additional heat (Ti c.p. TT) and Pd-Ag experimental groups. The copings for commercially pure titanium and titanium-aluminum-vanadium alloy were obtained in Rematitan System (Dentaurum). The experimental additional heat (Ti-6Ai-4V TT and Ti c.p. TT) was performed in original invested castings at first tiring porcelain temperature (800°C). The marginal fit was measured with the use of a measuring microscope (Olympus STM). The mean values of copings marginal fit were subjected lo analysis of variance (AN OVA) and Tukey's test with statistical significance set at the 5% probability level. The mean values of marginal fit after the complete firing cycle were: 106,78nm to Ti-6AI-4V, 86,02um to Ti-6AI-4V TT. 117,22fim to Ti c.p,, 115,71 um Ti c.p. TT and 98,70um to Pd-Ag, with no significant differences between these experimental groups. The marginal fit of Ti c.p. and Ti-6A1-4V was not significant influenced by Vitalitankeramic firing cycle. The Pd-Ag group revealed significant changes in marginal fit after firing of dentin porcelain and glaze / Mestrado / Materiais Dentarios / Mestre em Odontologia
169

Influencia da covergencia axial e do alivio interno na adaptação e resistencia a remoção por tração de coroas totais cimentadas com cimentos resinosos

Figueiro, Claudio 02 July 2001 (has links)
Orientador: Frederico Andrade e Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T12:24:23Z (GMT). No. of bitstreams: 1 Figueiro_Claudio_D.pdf: 2289324 bytes, checksum: a3194128299d48f7fd83c7c0526aa845 (MD5) Previous issue date: 2001 / Resumo: Este estudo avaliou a influência da convergência axial e do alivio interno na adaptação e resistência à tração de coroas totais cimentadas com o cimento resinoso Scothbond (3M) e com o cimento Enforce com Flúor (Dentsply). Foram realizados preparos padronizados do tipo coroa total em 160 dentes incisivos bovinos, nos quais foram confeccionadas coroas metálicas em NiCr. Foram formados oito grupos de acordo com: convergência axial (24° e 32°), utilização de alívio e agente cimentante utilizado. As coroas foram cimentadas seguindo as orientações dosífabricantes, utilizando uma carga estática de 9 Kgf durante 2 minutos. Os corpos-de-prova receberam uma ciclagem térmica (1500 ciclos nas temperaturas de 5°C ± 2°C e 550C ± 2°C). Metade das coroas foram seccionadas longitudinalmente utilizando um disco diamantado, no seu terço médio no sentido vestíbulo-lingual. As faces obtidas foram incluídas em resina acrílica autopolimerizável, sendo posteriormente realizado polimento com lixas d'água em uma politriz de bancada. A adaptação das coroas foi medida em um microscópio comparador (Leitz) com o aumento de 40X, e a resistência à tração foi medida em uma máquina de testes Universal (Instron). Os resultados foram agrupados e submetidos à uma análise de variância. O resultado da análise de variância mostrou-se significante ao nível de 5%, sendo realizado o teste de Tukey para a comparação das médias. Conforme a metodologia adotada concluiu-se que: 1) o aumento da convergência axial de 24° para 32°, melhorou a adaptação das coroas totais; 2) a utilização de alívio interno nas coroas totais melhorou a adaptação cervical; 3) o cimento resinoso Scotchbond proporcionou uma melhor adaptação cervical nas coroas totais quando comparado com o cimento Enforce; 4) o aumento da convergência axial de 24° para 32°, diminuiu a resistência à tração do cimento Scotchbond; 5) a utilização de alivio interno nas coroas totais diminuiu à resistência à tração das mesmas; 6) na convergência de 24°, o cimento Scotchbond apresentou maior resistência à tração quando comparado com o cimento Enforce / Abstract: The objective of this study was to evaluate the influence of axial convergence and relief on the marginal adaptation and retention of cemented complete crowns with Scothbond resin cement (3M) and Enforce resin cement (Dentsply). Sixteen hundred recently extracted bovine incisors were prepared to receive full cast crows, standardized preparations were made and the crows were made in a Ni-Cr alloy. Eight groups were formed according to: axial convergence (24° and 32°), relief and luting agent. The crowns were cemented according to the manufacturer's instructions, utilizing a 9 Kg static 1000 for two minutes. The specimens were thermocycled for 1500 cycles (5°C:t 2°C e 55°C ± 2°C). The crowns were sectioned with a diamond disk and polished. The marginal aptation was measured using a microscope with 40X of magnification (Leitz). The results were submitted to the ana1ysis of variance (ANOV A). The results of analysis were significant at the 5% leveI, and the Tukey multiple comparisons test was applied at the 5% leveI of significance. We concluded: 1) the crown adaptation was improved with the increase ofthe convergence ofthe 24° to 32°; 2) the crown adaptation was improved with the relief; 3) the crown adaptation was improved with scotchbond resin cement when it was comparable to enforce resin cement; 4) the increase of the convergence ofthe 24° to 32° decreased the crown retention to scotchbond resin cement; 5) The relief decreased the crown retention; 6) the crown retention was improved on axial convercence of24° to scotchbond resin cement when comparable to enforce resin cement / Doutorado / Protese Dental / Doutor em Clínica Odontológica
170

Torque de afrouxamento dos parafusos proteticos em proteses implanto-suportadas com diferentes niveis de desajuste / Loosening torque of prosthetic screws in implante-supported dentures with different fit levels

Spazzin, Aloísio Oro, 1984- 02 December 2009 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Campinas / Made available in DSpace on 2018-08-12T19:41:12Z (GMT). No. of bitstreams: 1 Spazzin_AloisioOro_M.pdf: 136206020 bytes, checksum: 3bd1b222bdf09c7c84975da4fc525ca7 (MD5) Previous issue date: 2009 / Resumo: O objetivo neste estudo foi verificar a influência da composição da liga (titânio ou ouro) e do re-aperto no torque de afrouxamento dos parafusos protéticos, sob diferentes níveis de desajustes (adaptação passiva e desajuste) de próteses mandibulares implantosuportadas. Foram confeccionadas 10 próteses totais mandibulares implanto-suportadas e criados dois níveis de desajustes, confeccionando 20 modelos de gesso (n = 10): próteses com adaptação passiva (G1_controle); e próteses com desajuste (G2). Para G1, as estruturas protéticas foram parafusadas diretamente aos análogos de mini-pilares cônicos. Para G2, os desajustes foram simulados utilizando anéis interpostos entre os cilindros da infra-estrutura e os análogos. O objetivo da interposição dos anéis foi obter média de 250 µm de desajuste no teste do parafuso único. Os análogos de todos os conjuntos montados foram incluídos em gesso utilizando delineador. Um microscópio óptico comparador (120x) foi usado para quantificar os valores de desajuste vertical no teste do parafuso único. As estruturas protéticas foram utilizadas para os dois níveis de desajustes. O torque de afrouxamento (TA) foi avaliado utilizando parafusos fabricados em liga de titânio (Ti) ou ouro (Au), sendo avaliadas também duas técnicas de aplicação de torque (10 Ncm): 1) torque e destorque após 24 horas (SR); e 2) torque, retorque após 10 minutos e destorque após 24 horas (CR). Foi utilizado torquímetro digital (TQ8800; Lutron) para aplicação do torque e leitura do TA. Os resultados foram submetidos à análise de variância de dois fatores (ANOVA) seguida do teste de Tukey (a=0,05). Os valores médios de TA (Ncm) para parafusos de Ti foram: G1/SR=6,99(±1,03); G1/CR=7,33(±0,79); G2/SR=5,65(±1,18); G2/CR=7,24(±1,00). Para parafusos de Au foram: G1/SR=5,42(±0,99);G1/CR=5,97(±1,00); G2/SR=5,03(±1,33); G2/CR=5,71(±1,02). No Capítulo-1, os materiais dos parafusos foram comparados sem aplicação do retorque (SR): Ti apresentou valor médio de TA mais elevado, diferindo estatisticamente do de Au no G1; o G2 apresentou menor valor médio de TA, diferindo estatisticamente do G1 para Ti. Não foi encontrada diferença estatística significante entre Ti e Au no G2, ou entre G1 e G2 para Au. No Capítulo-2, o retorque foi avaliado separadamente para Ti e Au. Para parafusos de Ti: o G2/SR apresentou menor valor médio de TA, diferindo estatisticamente do G1/SR; o G2/CR apresentou valor médio de TA mais elevado, diferindo estatisticamente de G2/SR; não foi encontrada diferença no valor médio de TA entre G1/CR e G2/CR, ou entre G1/SR e G1/CR. Para parafusos de Au, os grupos não apresentaram valores médios com diferença estatística entre si. Os materiais dos parafusos protéticos apresentaram comportamento diferente frente aos desajustes e retorque. A estabilidade da conexão dos parafusos de ouro não foi influenciada pelas variáveis avaliadas, enquanto os parafusos de titânio foram mais suscetíveis ao afrouxamento com aumento do desajuste, uma vez que o torque de afrouxamento diminuiu para valores semelhantes aos encontrados para os parafusos de ouro independentemente do nível de desajuste das próteses. Porém, a aplicação do retorque aumentou o torque necessário para afrouxar os parafusos de titânio para valores similares àqueles encontrados em próteses com adaptação passiva. / Resumo: O objetivo neste estudo foi verificar a influência da composição da liga (titânio ou ouro) e do re-aperto no torque de afrouxamento dos parafusos protéticos, sob diferentes níveis de desajustes (adaptação passiva e desajuste) de próteses mandibulares implantosuportadas. Foram confeccionadas 10 próteses totais mandibulares implanto-suportadas e criados dois níveis de desajustes, confeccionando 20 modelos de gesso (n = 10): próteses com adaptação passiva (G1_controle); e próteses com desajuste (G2). Para G1, as estruturas protéticas foram parafusadas diretamente aos análogos de mini-pilares cônicos. Para G2, os desajustes foram simulados utilizando anéis interpostos entre os cilindros da infra-estrutura e os análogos. O objetivo da interposição dos anéis foi obter média de 250 µm de desajuste no teste do parafuso único. Os análogos de todos os conjuntos montados foram incluídos em gesso utilizando delineador. Um microscópio óptico comparador (120x) foi usado para quantificar os valores de desajuste vertical no teste do parafuso único. As estruturas protéticas foram utilizadas para os dois níveis de desajustes. O torque de afrouxamento (TA) foi avaliado utilizando parafusos fabricados em liga de titânio (Ti) ou ouro (Au), sendo avaliadas também duas técnicas de aplicação de torque (10 Ncm): 1) torque e destorque após 24 horas (SR); e 2) torque, retorque após 10 minutos e destorque após 24 horas (CR). Foi utilizado torquímetro digital (TQ8800; Lutron) para aplicação do torque e leitura do TA. Os resultados foram submetidos à análise de variância de dois fatores (ANOVA) seguida do teste de Tukey (a=0,05). Os valores médios de TA (Ncm) para parafusos de Ti foram: G1/SR=6,99(±1,03); G1/CR=7,33(±0,79); G2/SR=5,65(±1,18); G2/CR=7,24(±1,00). Para parafusos de Au foram: G1/SR=5,42(±0,99);G1/CR=5,97(±1,00); G2/SR=5,03(±1,33); G2/CR=5,71(±1,02). No Capítulo-1, os materiais dos parafusos foram comparados sem aplicação do retorque (SR): Ti apresentou valor médio de TA mais elevado, diferindo estatisticamente do de Au no G1; o G2 apresentou menor valor médio de TA, diferindo estatisticamente do G1 para Ti. Não foi encontrada diferença estatística significante entre Ti e Au no G2, ou entre G1 e G2 para Au. No Capítulo-2, o retorque foi avaliado separadamente para Ti e Au. Para parafusos de Ti: o G2/SR apresentou menor valor médio de TA, diferindo estatisticamente do G1/SR; o G2/CR apresentou valor médio de TA mais elevado, diferindo estatisticamente de G2/SR; não foi encontrada diferença no valor médio de TA entre G1/CR e G2/CR, ou entre G1/SR e G1/CR. Para parafusos de Au, os grupos não apresentaram valores médios com diferença estatística entre si. Os materiais dos parafusos protéticos apresentaram comportamento diferente frente aos desajustes e retorque. A estabilidade da conexão dos parafusos de ouro não foi influenciada pelas variáveis avaliadas, enquanto os parafusos de titânio foram mais suscetíveis ao afrouxamento com aumento do desajuste, uma vez que o torque de afrouxamento diminuiu para valores semelhantes aos encontrados para os parafusos de ouro independentemente do nível de desajuste das próteses. Porém, a aplicação do retorque aumentou o torque necessário para afrouxar os parafusos de titânio para valores similares àqueles encontrados em próteses com adaptação passiva. / Abstract: The aim of this study was to verify the influence of alloy composition (titanium or gold) and retightening of the prosthetic screws on the loosening torque of these screws under different misfit levels (passive fit and misfit) of mandibular implant-supported prostheses. Ten mandibular implant-supported prostheses were fabricated. Two misfit levels of the prostheses were obtained fabricating twenty cast models using the prosthetic structures (n=10): prostheses with passive fit (G1_control); and prostheses with misfit (G2). For G1, the prosthetic structures were screwed directly to the analogs. For G2, the misfits were simulated using rings placed between the framework cylinders and the analogs. The analogs of all assembled sets were casted using delineator. The goal of the rings was to obtain mean of 250-µm misfit at one-screw test. An optic microscopic (120x) were used to quantifier the vertical misfit values at the one-screw test. The prosthetic frameworks were used in two misfit levels. The loosening torque (LT) was evaluated using screws made of titanium (Ti) or gold (Au) alloy, two techniques of torque application (10 Ncm) were also evaluated: 1) torque and loosening torque after 24 hours (wR); and 2) torque, retorque after 10 minutes and torque loosening after 24 hours (R). A digital torque meter (TQ8800; Lutron) was used to torque application and to measure the LT. Data were separately analyzed by two-away ANOVA followed by Tukey's test (a=0,05). The LT mean values (Ncm) for titanium screws were: G1/wR=6.99 (±1.03); G1/R=7.33(±0.79); G2/wR=5.65(±1.18); and G2/R=7.24(±1.00). For gold screws were: G1/wR=5.42(±0.99); G1/R=5.97(±1.00); G2/wR=5.03(±1.33); and G2/R=5.71(±1.02). In the Chapter-1, the screw materials were compared without retorque application (wR): Ti showed significant higher LT than Au in the G1; and G2 presented significant lower LT than G1 for Ti. No significant statistic difference was found between Ti and Au in the G2, or between G1 and G2 for Au screws. In the Chapter-2, the retorque was evaluated separately to Ti and Au. For titanium screws: the G2/wR showed lower LT than G1/wR; the G2/R presented higher LT than G2/wR; no significant difference on the LT between G1/R and G2/R; or between G1/wR and G1/R. For gold screws, the groups did not show mean values with statistic difference between each other. The prosthetic screw materials presented different behavior for the misfits and the retorque. The joint stability of the gold screw was not influenced by variables tested. While the titanium screws were more susceptible to the loosening with the misfit increase, once the loosening torque decreased to similar values those found for the gold screws regardless of the prosthetic fit level. However, the torque application increased the loosening torque of the titanium screws to similar values those found to the prostheses with passive fit. / Abstract: The aim of this study was to verify the influence of alloy composition (titanium or gold) and retightening of the prosthetic screws on the loosening torque of these screws under different misfit levels (passive fit and misfit) of mandibular implant-supported prostheses. Ten mandibular implant-supported prostheses were fabricated. Two misfit levels of the prostheses were obtained fabricating twenty cast models using the prosthetic structures (n=10): prostheses with passive fit (G1_control); and prostheses with misfit (G2). For G1, the prosthetic structures were screwed directly to the analogs. For G2, the misfits were simulated using rings placed between the framework cylinders and the analogs. The analogs of all assembled sets were casted using delineator. The goal of the rings was to obtain mean of 250-µm misfit at one-screw test. An optic microscopic (120x) were used to quantifier the vertical misfit values at the one-screw test. The prosthetic frameworks were used in two misfit levels. The loosening torque (LT) was evaluated using screws made of titanium (Ti) or gold (Au) alloy, two techniques of torque application (10 Ncm) were also evaluated: 1) torque and loosening torque after 24 hours (wR); and 2) torque, retorque after 10 minutes and torque loosening after 24 hours (R). A digital torque meter (TQ8800; Lutron) was used to torque application and to measure the LT. Data were separately analyzed by two-away ANOVA followed by Tukey's test (a=0,05). The LT mean values (Ncm) for titanium screws were: G1/wR=6.99 (±1.03); G1/R=7.33(±0.79); G2/wR=5.65(±1.18); and G2/R=7.24(±1.00). For gold screws were: G1/wR=5.42(±0.99); G1/R=5.97(±1.00); G2/wR=5.03(±1.33); and G2/R=5.71(±1.02). In the Chapter-1, the screw materials were compared without retorque application (wR): Ti showed significant higher LT than Au in the G1; and G2 presented significant lower LT than G1 for Ti. No significant statistic difference was found between Ti and Au in the G2, or between G1 and G2 for Au screws. In the Chapter-2, the retorque was evaluated separately to Ti and Au. For titanium screws: the G2/wR showed lower LT than G1/wR; the G2/R presented higher LT than G2/wR; no significant difference on the LT between G1/R and G2/R; or between G1/wR and G1/R. For gold screws, the groups did not show mean values with statistic difference between each other. The prosthetic screw materials presented different behavior for the misfits and the retorque. The joint stability of the gold screw was not influenced by variables tested. While the titanium screws were more susceptible to the loosening with the misfit increase, once the loosening torque decreased to similar values those found for the gold screws regardless of the prosthetic fit level. However, the torque application increased the loosening torque of the titanium screws to similar values those found to the prostheses with passive fit. / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Page generated in 0.0303 seconds