• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 814
  • 25
  • 24
  • 24
  • 23
  • 15
  • 14
  • 14
  • 8
  • 7
  • 7
  • 6
  • 2
  • 2
  • 1
  • Tagged with
  • 848
  • 320
  • 276
  • 251
  • 215
  • 202
  • 194
  • 192
  • 189
  • 181
  • 170
  • 164
  • 157
  • 123
  • 107
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Micromorfologia e resistência da união à dentina decídua tratada com dois sistemas adesivos estudo in vitro

Casagrande, Luciano January 2003 (has links)
O objetivo deste estudo in vitro foi avaliar a interação de dois sistemas adesivos (Scotchbond Multi-Purpose - 3M; Clearfil SE Bond - Kuraray) aplicados à dentina de dentes decíduos, através do ensaio de resistência da união à microtração, e da análise da micromorfologia da interface adesiva. Foram confeccionadas duas cavidades ocluso-proximais padronizadas (tipo slot vertical) na mesial e distal de dezoito molares decíduos hígidos. Cada um dos sistemas adesivos foi aplicado em uma das cavidades do mesmo dente. As cavidades foram restauradas com resina composta (Filtek Z 250 – 3M) pela técnica incremental, sendo cada camada fotopolimerizada por 20 s, utilizando uma fonte de luz visível (XL 2500 - 3M). Os dentes foram armazenados por uma semana em água destilada a 4o C e seccionados no sentido vestíbulo-lingual para análise isolada de cada restauração. Cada uma destas foi seccionada em fatias de 0,7 mm de espessura e, em seguida, efetuou-se uma constrição (1 mm) na região da interface de união (parede axial) para obtenção de uma área adesiva com aproximadamente 0,7 mm2. Os corpos-de-prova foram fixados isoladamente em um dispositivo conectado em uma máquina de ensaio universal (Instron – modelo 4411) e submetidos à tração com velocidade de 0,5 mm/min. As superfícies das secções fraturadas foram avaliadas ao MEV (Jeol –5600 LV) e categorizadas em relação aos padrões de fratura ocorridos. Adicionalmente, superfícies planas contendo a interface de união foram preparadas com lixas de carbureto de silício (granulação 1000) e polimento com pastas de diamante (6, 3, 1 e 0,25 µm). Após desidratação em sílica coloidal em temperatura ambiente por 24 h, as superfícies foram cobertas com liga de ouro e, a micromorfologia da união formada na parede axial das restaurações ocluso-proximais, analisadas ao MEV (Jeol –5600 LV). Os resultados do ensaio de resistência de união foram submetidos à análise estatística utilizando o teste t de student em nível de 5% de significância, e os tipos de fraturas e os aspectos micromorfológicos da interface adesiva submetidos à avaliação descritiva. Os valores médios de resistência de união dos adesivos Scothbond Multi-Purpose (21,84±9,90 MPa) e Clearfil SE Bond (25,19±5,33 MPa) não apresentaram diferenças estatisticamente significantes entre si (p=0,27). A análise do tipo de fratura revelou uma maior quantidade de falhas na região de dentina desmineralizada (G1: SMP) e na porção superior da camada híbrida (G2: CSE). A interface de união, em ambos os grupos, foi caracterizada pela formação da camada híbrida, projeção de prolongamentos resinosos adaptados à dentina e com direcionamento relacionado à disposição dos túbulos dentinários na área da cavidade avaliada.
142

Avaliação microtomográfica e da resistência de união de cimentos resinosos auto-adesivos à dentina intra-radicular

Pedreira, Ana Paula Ribeiro do Vale 19 January 2015 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2015. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2015-07-06T16:56:28Z No. of bitstreams: 1 2015_AnaPaulaRibeirodoValePedreira.pdf: 27996008 bytes, checksum: c09cea4e740ab2d24fb72a3c6c4580ca (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2015-08-18T14:41:22Z (GMT) No. of bitstreams: 1 2015_AnaPaulaRibeirodoValePedreira.pdf: 27996008 bytes, checksum: c09cea4e740ab2d24fb72a3c6c4580ca (MD5) / Made available in DSpace on 2015-08-18T14:41:22Z (GMT). No. of bitstreams: 1 2015_AnaPaulaRibeirodoValePedreira.pdf: 27996008 bytes, checksum: c09cea4e740ab2d24fb72a3c6c4580ca (MD5) / Introdução: Atualmente, o conhecimento acerca da interação dos cimentos auto-adesivos com a dentina intra-radicular é escasso. Informações detalhadas sobre a linha de cimentação e a interação com o substrato podem trazer dados preciosos na busca de uma união mais efetiva. Objetivo: Analisar a linha de cimentação de três cimentos resinosos autoadesivos e um resinoso dual convencional em dentina intra-radicular, por meio de microtomografia e do teste de push-out. Método: Três cimentos auto-adesivos (U100/3M ESPE, Maxcem/Kerr, Clearfil SA Bond/Kuraray) e um cimento resinoso dual convencional (Rely X ARC/3M ESPE) foram testados usando 2 técnicas de cimentação. O percentual de bolhas e a resistência de união foram quantificados de acordo com a técnica e os terços. 40 raízes de pré-molares humanos foram desobturadas na profundidade de 10mm. O cimento resinoso foi manipulado de acordo com a recomendação do fabricante. A inserção do cimento seguiu as orientações dos fabricantes para os grupos A e, para os grupos B, 40 pinos de fibra foram cimentados com o auxílio da ponta agulha de uma seringa centrix. As raízes foram escaneadas em um microtomógrafo e a linha de cimento foi analisada pelos softwares DataViewer, CTan, CTvol e CTvox. Após 07 dias, as raízes foram seccionadas perpendicularmente ao longo eixo e submetidas ao teste de extrusão. Os dados foram submetidos a ANOVA 3 critérios e Teste de Tukey. Resultados e Conclusão: A análise microtomográfica mostrou menor número de bolhas para os grupos B. A resistência de união foi significativamente maior para os auto-adesivos quando a seringa centrix foi utilizada (p<0,0001). A resistência de união decresceu em direção apical, independentemente da técnica e da distribuição das bolhas. Não houve relação entre os valores de resistência de união e a localização e volume de bolhas. A microtomografia mostrou-se um método eficaz na visualização e quantificação de bolhas na linha de cimentação. / Introduction: Currently, the knowledge about self-adhesive resin cements interaction with intraradicular dentin is scarce. Detailed information about the cement line and the interaction with the substrate can bring precious data for a more effective union.Purpose:to analyze the cement line of three self-adhesive resin cements and a conventional dual resin in intraradicular dentin through MicroCT analysis and push-out tests. Three self-adhesive cements (U100 / 3M ESPE, Maxcem / Kerr, Clearfil SA Bond / Kuraray) and a conventional dual resin cement (Rely X ARC / 3M ESPE) were tested using 2 lutingtechniques. The percentage of bubbles and the bond strength were measured according to technique and radicular thirds. Methods: 40 roots of human premolars wererestored in a depth of 10mm. Cement was mixed according to manufacturer's recommendation. The cement insertion followed the manufacturers guidelines for A and Bgroups; however, for B groups, fiber posts were cemented using a centrixsyringe. The roots were scanned in Skyscan 1076 and the cement line was analyzed by DataViewer, CTan, CTvol and CTvoxsoftwares. The roots were sectioned after 7 days, perpendicular to the long axis and subjected to push-out test. 3 way ANOVA and Tukey test were used. Results and Conclusion: The MicroCT analysis showed fewer bubbles for B groups. Bond strength was significantly higher for U100, Maxcem and Clearfil SA Cement whencentrix syringe was used (p <0.0001). The bond strength decreased in apical direction, regardless of cementation technique and bubbles location. There was no relationship between the bond strength values and bubbles location and volume. MicroCT proved to be an effective method for visualization and quantification of bubbles in the cement line.
143

Estudo das propriedades mecânicas da interface adesiva criada por sistemas adesivos convencional e autocondicionante, associados ou não ao laser Nd:YAG, utilizando a técnica da nanoindentação /

Silva, Patricia Rondon Pleffken da. January 2010 (has links)
Orientador: Sérgio Eduardo de Paiva Gonçalves / Banca: Alessandra Bühler Borges / Banca: Andrea Anido Anido / Resumo: O objetivo desta pesquisa foi avaliar a influência do laser Nd:YAG nas propriedades mecânicas (dureza e módulo de elasticidade) da interface adesiva, utilizando a técnica da nanoindentação, empregando-se sistema adesivo convencional Adper Single Bond 2 - 3M ESPE (SB) ou autocondicionante Clearfil SE Bond - Kuraray (CSE). Doze terceiros molares humanos tiveram suas superfícies oclusais desgastadas até a exposição da dentina superficial. Uma cavidade circular padronizada com fresa 3053 foi realizada na superfície oclusal proporcionando 2 mm de dentina remanescente. Os espécimes foram embutidos em resina acrílica, e seccionados no sentido mésio-distal, sendo as 24 hemi-coroas obtidas divididas em quatro grupos: Grupo controle (SBC) - aplicação do sistema SB de acordo com as recomendações do fabricante; Grupo laser (SBL) - aplicação do sistema adesivo SB e tratamento com laser Nd:YAG (140mJ/cm2/60s/não contato); Grupo controle (CSEC) - aplicação do sistema adesivo autocondicionante CSE de acordo com as recomendações do fabricante; Grupo laser (CSEL)- aplicação do sistema adesivo autocondicionante CSE e tratamento com laser Nd:YAG (140mJ/cm2/60s/não contato). Após a polimerização dos sistemas adesivos, foram aplicados dois incrementos da resina composta Filtek Z 350 (3M ESPE). Os corpos-de-prova foram imersos em água destilada e armazenados por 24h em estufa 37ºC e submetidos à nanoidentação em aparelho Nano Indenter® XP (MTS®, MN, EUA).. Os resultados foram submetidos aos testes estatísticos de Análise de Variância (ANOVA), Tukey e t-Student (p<0,05). Concluiu-se que a aplicação do laser Nd:YAG em ambos os sistemas adesivos não alterou o nível de dureza da interface adesiva, no entanto alterou o módulo de elasticidade / Abstract: The aim of this study was to evaluate the influence of Nd: YAG laser on the mechanical properties (hardness and modulus of elasticity) of the adhesive interface, using the technique of nanoindentation, employing conventional adhesive system Single Bond 2 3M ESPE (SB) or selfetching adhesive system Clearfil SE Bond - Kuraray (CSE). On 12 human molars, a flat superficial dentin surface was exposed by abrasion. A standardized circular cavity with bur 3053 was performed on the occlusal surface and dentin thickness was standardized in 2 mm. The specimens were embedded in resin acrylic and sectioned mesio-distally through their long axes, and the 24 hemi-crowns obtained divided into four groups: Control Group (SBC) - the application of SB system according to the manufacturer's recommendations; Laser Group (SBL) - SB adhesive system and treatment with Nd: YAG laser (140mJ/cm2/60s/no contact) Control Group (CSEC) - application of CSE self-etching adhesive system according to the manufacturer's recommendations; Laser Group (CSEL) - application of CSE self-etching adhesive system and treatment with Nd: YAG laser (140mJ/cm2/60s/no contact). After polymerization of the adhesives, were applied two increments of composite resin Filtek Supreme and specimens were immersed in distilled water and stored for 24 hours at 37 ºC and submitted to nanoidentation in Nano Indenter ® XP (MTS ®, MN, USA. Nanoindentation were made on composite resin, adhesive system, hybrid layer and dentin. The results were analyzed by a tree-way ANOVA, Tukey and e t-Students (p<0,05). It was concluded that the application of Nd:YAG laser in both adhesive systems did not change hardness level of hybrid layer, however chanded the elastic modulus / Mestre
144

Dentina hibridizada afeta a adesão do cimento resinoso autoadesivo?

Pamato, Saulo January 2014 (has links)
Made available in DSpace on 2016-11-30T14:53:36Z (GMT). No. of bitstreams: 2 110926_Saulo.pdf: 50165254 bytes, checksum: 1cbd8cfb1c609a3b37c6e61d474f074d (MD5) license.txt: 214 bytes, checksum: a5b8d016460874115603ed481bad9c47 (MD5) Previous issue date: 2014 / Os cimentos resinosos são compósitos resinosos de baixa viscosidade indicados na retenção e selamento marginal de restaurações indiretas, diferindo entre si de acordo com o pré-tratamento proposto previamente a etapa de cimentação. Por sua vez, os cimentos resinosos autoadesivos surgiram no mercado exibindo características de um protocolo simples de aplicação, contrapondo-se a sensibilidade técnica dos demais cimentos resinosos adesivos. Este trabalho se propôs a avaliar a influência de diferentes técnicas de hibridização na adesão de um cimento resinoso autoadesivo. Para tal, 30 molares humanos hígidos, oriundos de um banco de dentes, foram divididos em 6 grupos (n=10). Os espécimes receberam 3 secções longitudinais possibilitando a inclusão dos cortes centrais em matrizes de PVC. Com exceção do grupo controle (G1), cada grupo recebeu um pré-tratamento dentinário distinto de acordo com as recomendações do fabricante: G2 - condicionamento ácido total com sistema de 3 passos (Optibond¿ FL, Kerr), G3 - condicionamento ácido total com sistema de 3 passos (Adper¿ Scotchbond¿ Multi- Purpose, 3M ESPE), G4 - condicionamento ácido total com sistema de 2 passos (Adper¿ Single Bond 2, 3M ESPE), G5 - sistema autocondicionante de passo único (Bond Force, Tokuyama), G6 - sistema universal (Single Bond Universal, 3M ESPE). Em seguida, todos os grupos receberam a cimentação de um cilindro de cimento resinoso autoadesivo (RelyX U200, 3M ESPE) confeccionado a partir de uma matriz de polipropileno. Na avaliação da resistência de união, os corpos de prova foram submetidos ao teste de microcisalhamento e avaliados de acordo com o padrão de fratura por meio de microscopia óptica. Os resultados foram submetidos ao teste de Kruskal-Wallis, sugerindo diferença estatística significativa entre os grupos (p=0,04), e Tukey para comparações múltiplas, apontando diferença estatística significativa entre G1 e G3 (p<0,05). Quanto à análise microscópica, constatou-se alta predominância de falhas adesivas, seguido de falhas mistas e coesivas em dentina. Considerando as limitações do presente estudo, conclui-se que o emprego de um protocolo prévio de hibridização dentinária é capaz de elevar os valores de resistência a união do cimento resinoso autoadesivo, principalmente frente a utilização do sistema Adper¿ Scotchbond¿ Multi-Purpose. / The resin cements are composte resin of the low viscosity indicated in retention and marginal sealing of indirect restorations, differing from each other in accordance with pre-treatment previously proposed to the cementation step. In turn, the self-adhesive resin cements come onto de market showing features of a simple application protocol, countering the technical sensivity of the others resin cements. This study aimed to evaluate the effect of different hybridization techniques in adhesion of a self-adhesive resin cement. For such, 30 human molars, coming from a teeth's bank, were divided into 6 groups (n=10). The specimens received 3 longitudinal sections allowing the inclusion of central cuts in PVC matrix. Except the control group (G1), each group has received a different dentin pretreatment according with to the manufacturer's recommendations: G2 - etch & rinse system with 3 steps (Optibond¿ FL, Kerr), G3 - etch & rinse system with 3 steps (Adper¿ Scotchbond¿ Multi- Purpose, 3M ESPE), G4 - etch & rinse system with 2 steps (Adper¿ Single Bond 2, 3M ESPE), G5 - self-etching system with only step (Bond Force, Tokuyama), G6 - universal system (Single Bond Universal, 3M ESPE). Then all groups received the cementing of a self-adhesive resin cement cylinder (RelyX U200, 3M ESPE) made from a polypropylene matrix. In the evaluation of bond strength, the samples were subjected to the microshear test and evaluated according to the fracture pattern by optical microscopy. The results were submitted to the Kruskal-Wallis test, suggesting a statistically significant difference between groups (p=0,04), and Tukey for multiple comparisons, indicating a statistically significant difference between G1 and G3 (p<0.05). As regard the microscopic analysis, it was verified high prevalence of adhesive failures, followed by mixed failure and cohesive in dentin. Giving the limitations of this study, it is concluded that the use of a previous protocol of dentin hybridization is able to raise the values of resistance the union of the self-adhesive resin cement, mainly when using the Adper¿ Scotchbond¿ Multi-Purpose system.
145

Avaliação imediata e após 6 meses da resistência de união a dentina de restaurações de resina composta classe I in vivo e in vitro

Rêgo, Heleine Maria Chagas [UNESP] 23 June 2015 (has links) (PDF)
Made available in DSpace on 2016-06-07T17:12:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-06-23. Added 1 bitstream(s) on 2016-06-07T17:17:18Z : No. of bitstreams: 1 000865416.pdf: 2581195 bytes, checksum: baec4e58131e8a8b1372e9f152ca300b (MD5) / Este estudo avaliou a resistência de união a dentina de restaurações de resina composta de forma imediata (24 horas) e em longo prazo (6 meses), submetidos a diferentes protocolos de envelhecimento. Cem dentes posteriores humanos foram divididos em cinco grupos (n = 20) de acordo protocolo de envelhecimento que receberam e posteriormente subdivididos em dois subgrupos (n = 10) de acordo com o tempo de armazenamento, totalizando dez subgrupos: In vivo (permaneceu em atividade bucal por 24 horas ou 6 meses); Estufa (armazenado em água destilada em estufa a 37 °C por 24 horas ou 6 meses); Ciclagem (submetidos a 27/666 ou 5000/120000 ciclos termomecânicos); Estufa com Pressão Pulpar Simulada (PPS) (restauração realizada sob PPS e em seguida armazenado em água destilada em estufa a 37 °C por 24 horas ou 6 meses); Ciclagem com PPS (restauração realizada sob PPS e em seguida submetidos a 27/666 -24 horas- ou 5000/120000 -6 meses- ciclos termomecânicos). Após a abertura da cavidade, a restauração foi realizada com a aplicação de ácido fosfórico a 37% (Vigodent), sistema adesivo Adper Single Bond 2 (3M ESPE) e resina composta Grandio (Voco), seguindo a orientação dos fabricantes. Após os diferentes tratamentos os espécimes foram seccionados obtendo-se palitos que foram submetidos ao teste de microtração. Os valores obtidos foram submetidos ao teste ANOVA dois fatores (protocolo de envelhecimento e tempo de armazenamento) e em seguida ao Teste de Tukey (5%). Os resultados para os testes de microtração foram (em MPa ±dp): Grupo estufa 24 h, 24,96±0,95A; Grupo ciclagem 24 horas, 23,96 ± 0,56AB; Grupo in vivo 24 horas, 23,21 ± 1,23AB; Grupo ciclagem com PPS 24 horas, 19,49 ± 1,51BC, Grupo ciclagem 6 meses, 18,16 ± 0,80CD; Grupo ciclagem com PPS 6 meses, 17,88 ± 1,25CD; Grupo estufa com PPS 24 horas, 17,65 ± 0,45CD; Grupo estufa 6 meses, 16,68 ± 1,30CD; Grupo estufa com PPS 6 meses, 14,33 ± 1,48D; Grupo in vivo 6 meses,.... / This study evaluated the bond strength of composite resin restorations submitted to different storage aging protocols, immediately and long-term (6 months). One hundred human posterior teeth were divided into five groups (n = 20) according storage aging protocol: Group, Group in vivo, Group water, Group cycling, Group water with Simulated Pulpal Pressure (PPS) and Group cycling with Simulated Pulpal Pressure. As further subdivided into two subgroups (n = 10) according to the time of storage were performed: 24 hours (24 hours in vivo 24 hours in water, 27/666 thermal and mechanical cycles) 6 months (6 months in vivo, 6 months in water and 5000/120000 thermal and mechanical cycles). After the opening of the cavity, the restoration was carried out with the use of phosphoric acid 37% (Vigodent), Single Bond 2 adhesive system (3M ESPE) and composite resin Grandio (Voco), following the lead of the manufacturers. After being held aging protocols for the storage time subgroup belonging specimens were sectioned obtaining sticks were submitted to microtensile test. Data were submitted to ANOVA two factors (aging and storage time) and then Tukey test (5%). The results for the microtensile tests were (MPa) ± SD: Group water 24 hours, 24.96 ± 0.95A; Group cycling 24 hours, 23.96 ± 0.56AB; Group in vivo 24h, 23.21 ± 1.23AB; Group cycling with PPS 24 hours, 19.49 ± 1.51BC, group cycling six months, 18.16 ± 0.80CD; Group cycling with PPS 6 months, 17.88 ± 1.25CD; Group water with PPS 24 hours, 17.65 ± 0.45CD; Group water 6 months, 16.68 ± 1.30CD; Group water with PPS 6 months, 14.33 ± 1,48D; In vivo group 6 months, 14.16 ± 1,51D. It was concluded that the different aging protocols used as storage times influence the bond strength dentin-resin
146

Influência de uma substância antioxidante na união de materiais resinosos à dentina após a realização de clareamento /

Toseto, Roberta Mariano. January 2010 (has links)
Orientador: André Luiz Fraga Briso / Banca: Paulo Henrique dos Santos / Banca: Mirela Sanae Shinohara / Resumo: Este estudo analisou a influência do ascorbato de sódio 10% (AS) na formação de tags e camada híbrida em dentina após clareamento dental. Materiais e métodos: Foram testados 6 grupos. GI- Controle: somente restaurações de Resina Composta (RC); GII- Ascorbato de Sódio (AS) + RC; GIII- clareamento com peróxido de carbamida 10% (PC) + RC; GIV- PC + AS + RC; GV- clareamento com peróxido de hidrogênio 35% (PH) + RC; GVI- PH + AS + RC. Após os tratamentos, os dentes foram seccionados e descalcificados. Os cortes foram montados em lâminas de vidro e corados pelo método Brown & Brenn. A análise em microscopia óptica comum (Axiophot) em 400X, evidenciou os tags e camada híbrida formados. Resultados: Os dados foram tabulados, sendo obtidas as respectivas médias para comprimento dos tags e a espessura da camada híbrida: GI- 10 e 3.1μm, GII- 9.2 e 2.4 μm, GIII- 5.4 e 1.5 μm, GIV- 6.8 e 2.1 μm, GV- 5.7 e 1.6 μm, GVI- 7.1 e 2.1 μm. Conclusão: O clareamento dental com PC ou PH prejudica a formação de tags resinosos e camada híbrida. O uso do AS aumentou o comprimento destas estruturas / Abstract: This study analyzed the influence of 10% sodium ascorbate (SA) on tag and hybrid layer formation in dentin after bleaching. Materials and Methods: Six groups were tested: GI- Control: restoration; GII- Sodium Ascorbate (SA) + restoration; GIII- Bleaching with carbamide peroxide (CP) + restoration; GIV- bleaching with CP + SA+ restoration; GV- bleaching with 35% hydrogen peroxide (HP) + restoration; and GVI- HP + SA + restoration. After treatments, the teeth were sectioned and decalcified. The length of resin tags and thickness of the hybrid layer were analyzed using optical microscopy (Axiophot). Results: The following results were obtained for the groups: GI- 10 and 3.1 μm, GII- 9.2 and 2.4 μm, GIII- 5.4 and 1.5 μm, GIV- 6.8 and 2.1 μm, GV-5.7 and 1.6 μm, GVI-7.1 and 2.1 μm (length of resin tags and thickness of the hybrid layer, respectively). Conclusion: Dental bleaching with CP or HP impairs the formation of resin tags and hybrid layer. The use of SA increases these measures / Mestre
147

Painéis de medium density fiberboard produzidos com adesivo alternativo /

Eugênio, Rafael Augusto Pinholati. January 2016 (has links)
Orientador: Ivaldo De Domenico Valarelli / Banca: Rosane Aparecida G. Basttistelle / Banca: Alexandre Jorge Duarte Souza / Resumo: O trabalho consistiu na produção de painéis de MDF (Medium Density Fiberboard) em escala laboratorial utilizando o adesivo PVA (Poliacetato de Vinila), variando suas concentrações e realizando misturas com a resina comumente empregada neste processo, o adesivo a base de uréia-fomaldeído, onde foi avaliado além das características físicas e mecânicas dos painéis produzidos, também teve o intuito de verificar o desprendimento de formaldeído para o ambiente quando aplicado juntamente com a resina uréia-fomaldeído, e a avaliação dos perfis de densidades dos traços. As amostras foram confeccionadas com fibra de eucalipto, onde as dosagens do adesivo PVA seguiram as seguintes proporções: 30%, 50% e 70%, e para efeito de comparação com as amostras produzidas com a mistura de PVA foram fabricadas provas em branco com 100% uréia-formaldeído. No total foram produzidas 16 amostras, quatro painéis de cada traço, e retirados os corpos de prova que posteriormente foram avaliados conforme a NBR 15316-2:2015 para as condições secas. Todos os insumos foram fornecidos pelo fabricante de painéis Duratex SA, e os testes foram realizados nos laboratórios da empresa. O adesivo PVA mostrou-se bastante favorável, apresentando grande compatibilidade com os demais componentes da formulação, apresentando potencial para fabricação de MDF. Diversos traços conseguiram atender os requisitos da norma, com destaque para módulo de ruptura (MOR), módulo de elasticidade (MOE), obtidos atraves do ensaio de flexã... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The work consisted in the production of MDF (Medium Density Fiberboard) in laboratory seade using PVA adhesive (Polyacetate Chloride), varying their concentration and perfomring mixtures with commonly used resin in this process the adhesive base of urea-fomaldehyde, which was evaluated in addition to the physical and mechanical characteristics of the panels produced, also aimed to check the formaldehyde release to the environment when applied together with resin urea-formaldehyde, and evaluation of the desnsities of the features profiles. The samples were made from eucalyptus fibers where PVA adhesive doses followed proportions: 30%, 50% and 70%, and for the purpose of comparison with the samples produced with the samples produced with the mixture of PVA blank tests were made with 100% urea-formaldehyde. In total, we produced 16 samples, four panels of each stroke, and removed the speciments which then evaluated according to NBR 15316-2:2015 for dry conditions. All inputs were provided by the panel manufacturer Duratex SA, and the tests were performed in the company's laboratories. PVA adhesive proved to be very favorable, with high compatibility with the other components of the formulation, with potential for the production of MDF. Many features were able to meet the standard requirements, particularly modulus of rupture (MOR), modulus of elasticity (MOE), obtained through the bending, and moisture content test. There was also a slight reduction in formaldehyde emissions by two dashes (T3 and T4), and evaluation of density profiles was found that the formulation of the traits did not affect the average thickness of the thickness of the panels / Mestre
148

Durabilidade da resistência adesiva entre uma cerâmica feldspática e cimento resinoso : efeito do tipo de adesivo e do cimento resinoso /

Vanderlei, Aleska Dias. January 2008 (has links)
Orientador: Luiz Felipe Valandro / Banca: Luiz Felipe Valandro / Banca: Marco Antonio Bottino / Banca: Roberto Ruggiero Braga / Resumo: O objetivo do trabalho foi avaliar o efeito de diferentes adesivos e da ciclagem térmica / armazenagem na adesão entre uma cerâmica feldspática e três cimentos resinosos (fotopolimerizável, dual e químico). A hipótese é que quanto menor o pH do adesivo, mais baixa é a resistência adesiva, especialmente na cimentação com cimento resinoso quimicamente ativado. Noventa blocos (6 x 6 x 4mm) de cerâmica feldspática microparticulada (Vita VM7) foram confeccionados. A superfície cerâmica foi tratada com ácido fluorídrico 10%/20 s e silanizada (Porcelain Primer, Bisco). Então, os diferentes adesivos foram aplicados conforme as recomendações do fabricante (Scotchbond Multi-Purpose Plus Adhesive [SBMP], pH = 5,6; Single Bond [SB], pH = 3,4; Prime & Bond NT [PBNT], pH = 1,7). Após, os blocos tratados foram reposicionados em moldes de silicone individuais e os cimentos resinosos (CR) foram aplicados (fotopolimerizável (Variolink base, Ivoclar Vivadent); dual (Variolink base + catalizador, Ivoclar Vivadent); químico (C&B, Bisco)). Assim, nove grupos foram constituídos (N=10 espécimes por grupo): (1) PBNT + CR químico, (2) PBNT + CR dual, (3) PBNT + CR foto, (4) SB + CR químico, (5) SB + CR dual, (6) SB + CR foto, (7) SBMP + CR químico, (8) SBMP + CR dual, (9) SBMP + CR foto. Os espécimes foram armazenados em água destilada (37°C) por 24 h e então seccionados no sentido x e y, a fim de obter corpos de prova (cp) em forma de barras com área adesiva de ±1mm2. Os cp de cada bloco foram aleatoriamente divididos em 2 condições de armazenagem: Seco- ensaio imediato; TCarmazenagem 150 dias (37oC) + ciclagem térmica (12.000x, 5°C-55°C). Considerando os 3 fatores do estudo (adesivo [3 níveis], cimento resinoso [3 níveis] e armazenagem [2 níveis]), foram constituídos 18 grupos (fatorial 3x3x2). O teste de microtração foi realizado numa máquina de ensaio universal... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the effect of different adhesives and of the thermal cycling / storage (TC) on the bond strength of resin cement (RC) (photo/dual/self-cure) to a feldspathic ceramic. The hypothesis is as lower the pH of the adhesive, the lower the bond strength, especially in the cementation with resin cement chemical. Ninety blocks (6 x 6 x 4mm) (N=90) of the feldspathic ceramic (VM7-VITA) were made according to the manufacturer's recommendations. The ceramic surface was conditioned with hydrofluoric acid 10% (Dentsply) for 20 s + silane (Porcelain Primer, Bisco). Three adhesives (Scotchbond Multi-Purpose Plus Adhesive (SBMP, 3M ESPE; pH = 5.6); Single Bond (SB, 3M ESPE; pH = 3.4); Prime & Bond NT (PBNT, Dentsply; pH = 1.7)) were applied. After, three RC with different cure were applied: Photo (Variolink II base, Ivoclar Vivadent); Dual (Variolink II base + catalyst, Ivoclar Vivadent); self-cured (C&B, Bisco). Therefore, nine groups were constituted (N=10 specimens for group): (1) PBNT + RC chemical, (2) PBNT + RC dual, (3) PBNT + RC photo, (4) SB + RC chemical, (5) SB + RC dual, (6) SB + RC photo, (7) SBMP + RC chemical, (8) SBMP + RC dual, (9) SBMP + RC photo. The specimens were stored (37°C/24h) and then sectioned (adhesive area: ± 1 mm²). The specimens of each block were random divided in 2 aging conditions: Dry- microtensile test after cutting; TC- storage 150 days (37oC) + thermo-cycling (x12.000, 5°C-55°C). Considering 3 factors of the study (adhesive [3 levels], resin cement [3 levels] and aging [2 levels]) (factorial 3x3x2), 18 testing groups were composed. The tensile bond strength test was carried in a universal testing machine (cross-head speed: 1 mm/min). The 3-way ANOVA showed that the results of the bond strength were affected by the factors adhesive (P=0,0001) and resin cement (P=0,0003)... (Complete abstract, click electronic access below) / Doutor
149

Influência da utilização de um adesivo para prótese na satisfação e nos parâmetros cinesiográficos de usuários de próteses totais /

Mendoza Marin, Danny Omar. January 2013 (has links)
Orientador: Marco Antonio Compagnoni / Banca: Ana Carolina Pero / Banca: Claudia Helena Lovato da Silva / Resumo: Objetivo: O objetivo deste estudo foi avaliar o efeito da utilização de um adesivo para prótese na satisfação e nos parâmetros cinesiográficos em usuários de próteses totais por meio de um estudo "cross-over". Material e Métodos: Cinquenta pacientes desdentados receberam novas próteses totais bimaxilares. Após um período de adaptação, os participantes incluídos no estudo receberam uma sequência de tratamento: protocolo 1- utilização do adesivo para prótese durante os primeiros 15 dias, seguida por não utilização do adesivo os próximos 15 dias; protocolo 2- não utilização do adesivo durante os primeiros 15 dias; seguida por utilização do adesivo os próximos 15 dias. Os resultados foram avaliados após 15 dias de cada sequência de tratamento. Um questionário para avaliar a satisfação dos pacientes e um cinesiógrafo para registrar os movimentos mandibulares e o padrão de movimento da prótese total maxilar durante mastigação foram utilizados. O teste de "Wilcoxon" (α=0,05) e o "t-test" de student para amostras pareadas (α=0,05) foram utilizados para comparar o grau de satisfação dos pacientes e os dados cinesiográficos, respectivamente. Resultados: O adesivo para prótese melhorou significativamente a satisfação geral dos participantes (p<0,001). Os registros cinesiográficos mostraram um aumento significativo (1,7mm) no movimento mandibular vertical (p<0,001) e uma menor intrusão (0,3mm) da prótese total superior (p=0,002) durante a mastigação após o uso de adesivo. Conclusão: O uso de adesivo para prótese melhorou a satisfação dos usuários de próteses totais e gerou um aumento no movimento mandibular vertical e uma menor intrusão da prótese total maxilar durante a mastigação / Abstract: Objectives: The objective of this study was to evaluate the effect of a denture adhesive (DA) on patient satisfaction and kinesiographic parameters of complete denture wearers by a cross-over study. Material and Methods: Fifty edentulous patients received one set of new complete dentures. After an adaptation period, the participants were enrolled in the trial and randomized to receive a sequence of treatment: protocol 1- DA use during the first 15 days, followed by the no use of DA over the next 15 days; protocol 2- no use of DA during the first 15 days, followed by use of DA over the next 15 days. Outcomes were assessed after 15 days of each sequence of treatment. A questionnaire was used to evaluate patients' satisfaction and a kinesiograph instrument was used to record mandible movements and pattern of maxillary complete denture movement during chewing. Wilcoxon test (α=.05) and a paired sample t-test (α=.05) were used to compare satisfaction levels and kinesiographic data, respectively. Results: The use of DA improved the overall patients' satisfaction (p<.001). Kinesiographic recordings revealed a significant increase (1.7mm) on vertical mandible movements (p<0,001) during chewing and a lower (.3mm) vertical intrusion of the maxillary complete denture (p=0,002) during chewing after use of DA. Conclusion: The use of a DA in complete dentures wearers improved the patients' satisfaction and change mandible movements, with increases in vertical mandible movements during chewing and lower intrusion of maxillary complete denture / Mestre
150

Aplicação de sistemas adesivos à dentina irradiada com laser de Nd:YAG: estudo da durabilidade da resistência de união

Heredia, Alexandre Rodriguez January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:00Z (GMT). No. of bitstreams: 2 000386620-0.pdf: 4419256 bytes, checksum: 54dfaa1b101b15fa40cdba9832bc4351 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The purpose of this study was to evaluate, in vitro, the influence of Nd:YAG laser in bond strength of the Single Bond 2 and Clearfil SE Bond adhesive systems to dentin, as well as durability of such bond, and superficial topography of the laser irradiated dentin. A flat occlusal surface was obtained in extracted third human molars being it regulated with 320, 400 and 600 grit silicon carbide sandpaper, respectively. Teeth were randomly divided in 8 groups: Group 1 - Single Bond 2; Group 2 - Clearfil SE Bond; Group 3 – laser and Single Bond 2; Group 4 – laser and Clearfil SE Bond. Nd:YAG laser was applied in dentin previously to adhesive system in the following parameters: 60mJ, 15Hz and 0,9W. After applying adhesive systems, composite resin blocks with 6 mm height were built. Samples from these groups were stored in distilled water at 37º C for 24 hours. Samples from Groups 5, 6, 7 and 8 were identical to Groups 1, 2, 3 and 4, respectively, being stored in distilled water at 37º C for 7 months. After storage period, groups of tooth/resin were cut in a parallel way along the tooth axis in buccal-lingual and mesio-distal directions with cut of approximately 0,7 mm. It was obtained 25 specimens for each group, being, then, submitted to microtensile bond strength on a universal testing machine at a crosshead speed of 0,5mm/min. Superficial topography of dentin with laser application was observed in MEV. According to Variance Analysis and Tukey test (a=0,05), group 1 (Single Bond 2, 24 h = 19,79 MPa), group 5 (Single Bond 2, 7 months = 21,58 MPa), and group 7 (Single Bond 2, with laser, 7 months = 17,80 MPa) did not differ statistically amongst and were statistically higher than all Clearfil SE Bond groups. For Single Bond 2, the lowest mean was obtained by group 3 (Single Bond 2, with laser, 24 hours = 12,44 MPa), not statistically differing from group 7 (Single Bond 2, with laser, 7 months). The lowest means were obtained with Clearfil SE Bond groups, which did not statistically differ amongst, being obtained the following means: group 2 (11,39 MPa), group 4 (10,60 MPa), group 6 (11,16 MPa) and group 8 (9,56 MPa). According to analysis in MEV, Nd:YAG laser altered dentin superficial topography. It was concluded that Nd:YAG laser significantly reduced resistance to microtensile bond strength only for Single Bond 2 adhesive system when stored for 24 hours, and that laser did not significantly implicate bond durability in a period of 7 months for tested adhesive systems. / O objetivo desse estudo foi avaliar, in vitro, a influência do laser de Nd:YAG na resistência de união dos sistemas adesivos Single Bond 2 e Clearfil SE Bond sobre a dentina, assim como a longevidade desta união e a topografia superficial da dentina irradiada com o laser. Em terceiros molares humanos extraídos foi obtida uma superfície oclusal plana em dentina, sendo a mesma regularizada com lixas de carbeto de silício de granulação 320, 400 e 600, respectivamente. Os dentes foram divididos aleatoriamente em 8 grupos: Grupo 1 - Single Bond 2; Grupo 2 - Clearfil SE Bond; Grupo 3 – laser e Single Bond 2; Grupo 4 – laser e Clearfil SE Bond. O laser de Nd:YAG foi aplicado na dentina previamente ao sistema adesivo nos seguintes parâmetros: 60 mJ, 15 Hz e 0,9 W. Após a aplicação dos sistemas adesivos, foram construídos blocos de resina composta com 6 mm de altura. As amostras destes grupos foram armazenadas em água destilada a 37º C por 24 horas. As amostras dos Grupos 5, 6, 7 e 8 foram idênticas as dos Grupos 1, 2, 3 e 4, respectivamente, sendo armazenadas em água destilada a 37º C por 7 meses. Decorrido o período de armazenagem, os conjuntos dente/resina foram cortados paralelamente ao longo eixo do dente, nos sentidos vestíbulo-lingual e mésio-distal, com secção de aproximadamente 0,7 mm. Foram obtidos 25 corpos-de-prova para cada grupo, sendo então submetidos ao teste de resistência à microtração em máquina de ensaio universal com velocidade de 0,5 mm/min.A topografia superficial da dentina com aplicação do laser foi observada em MEV. De acordo com a Análise de Variância e o teste de Tukey (a=0,05), o grupo 1 (Single Bond 2, 24 hs = 19,79 MPa), o grupo 5 (Single Bond 2, 7 meses = 21,58 MPa), e o grupo 7 (Single Bond 2, com laser, 7 meses = 17,80 MPa) não diferiram estatisticamente entre si e foram estatisticamente superiores a todos os grupos do Clearfil SE Bond. Para o Single Bond 2, a menor média foi obtida para o grupo 3 (Single Bond 2, com laser, 24 horas = 12,44 MPa), não diferindo estatisticamente do grupo 7 (Single Bond 2, com laser, 7 meses). As menores médias foram obtidas com os grupos do Clearfil SE Bond, as quais não diferiram estatisticamente entre si, sendo obtidas as seguintes médias: grupo 2 (11,39 MPa), grupo 4 (10,60 MPa), grupo 6 (11,16 MPa) e grupo 8 (9,56 MPa). De acordo com a análise em MEV, o laser de Nd:YAG alterou a topografia superficial da dentina. Concluiu-se que o laser de Nd:YAG reduziu significativamente a resistência à microtração apenas para o sistema adesivo Single Bond 2 quando armazenado por 24 horas, e que o laser não comprometeu significativamente a durabilidade da união no período de 7 meses para os sistemas adesivos testados.

Page generated in 0.045 seconds