• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 814
  • 25
  • 24
  • 24
  • 23
  • 15
  • 14
  • 14
  • 8
  • 7
  • 7
  • 6
  • 2
  • 2
  • 1
  • Tagged with
  • 848
  • 320
  • 276
  • 251
  • 215
  • 202
  • 194
  • 192
  • 189
  • 181
  • 170
  • 164
  • 157
  • 123
  • 107
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Caracterização de adesivos de altas temperaturas para aplicações aeroespaciais

Sousa, Filipa Salomé Marques de January 2010 (has links)
Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2010
112

Adesivos de contacto na CaetanoBus

Almeida, Cátia Sofia Guedes January 2009 (has links)
Estágio realizado na CaetanoBus e orientado pelo Eng.ª Manuela Pereira / Tese de mestrado integrado. Engenharia Metalúrgica e de Materiais. Faculdade de Engenharia. Universidade do Porto. 2009
113

Efeito de diferentes concentrações de alfatocoferol em gel sobre a adesão em dentes tratados endodonticamente e clareados /

Marcomini, Natalia. January 2019 (has links)
Orientador: Andréa Abi Rached Dantas / Resumo: Estudos têm encontrado resultados promissores para o uso de antioxidantes na reversão da redução da adesão, ocasionada pela impregnação de radicais livres em dentina clareada. O objetivo do presente estudo foi avaliar o efeito de diferentes concentrações (15, 20 e 25%) de um gel de alfatocoferol na resistência à fratura, formação de camada híbrida e resistência de união de um adesivo em substrato clareado com peróxido de hidrogênio 38% (PH 38%). Sessenta incisivos bovinos foram distribuídos em 6 grupos (n=10): G1 - sem tratamento clareador (controle negativo); G2 - PH 38% (controle positivo); G3 - PH 38% + alfatocoferol gel 15%; G4 - PH 38% + alfatocoferol gel 20%; G5 - PH 38% + alfatocoferol gel 25%; G6 - PH 38% + ascorbato de sódio gel 10%. Os dentes foram preparados, submetidos a 3 aplicações de 15min de PH 38%. Os respectivos antioxidantes foram aplicados por 10 min e, em seguida, os dentes foram restaurados. O teste de resistência à fratura foi realizado 24h após o procedimento clareador em máquina de ensaio mecânico (EMIC). A formação da camada híbrida foi avaliada por meio de microscopia eletrônica de varredura (MEV) e a resistência de união, por meio do teste de microtração. Os dados obtidos com cada um dos três experimentos independentes foram submetidos à análise estatística específica (Kruskal Wallis/Dunn - a=0,05). Para o teste de resistência à fratura não foi observada diferença estatisticamente significativa entre os grupos experimentais. Por meio da análise em ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The release and impregnation of free radicals in dentin damage the bond strength on bleaching teeth. The use of antioxidants has emerged as an interesting alternative to solve this problem. The aim of this study was evaluating the effect of different concentrations (15, 20 e 25%) of an alpha-tocopherol gel on fracture resistance, hybrid layer formation and bond strength of an adhesive system used in endodontic treated and bleached teeth (hydrogen peroxide 38% - HP 38%). Sixty bovine incisors were divided into six groups (n=10): G1 - negative control; G2 - 38% HP (positive control); G3 - 38% HP + 15% alpha-tocoferol; G4 - 38% HP + 20% alpha-tocoferol; G5 - 38% HP + 25% alpha-tocoferol; G6 - 38% HP + 10% sodium ascorbate. The specimens were prepared and submitted a bleaching using a gel with 38% HP (3x15 minutes). The antioxidant gels were applied for 10 minutes and the teeth was restored. The fracture resistance mechanical testing was realized 24 hours after. The analyze of the hybrid layer was done by scanning electron microscope (SEM). And the bond strength was analyzed by the microtensile bond strength test. Data were subjected to specific statistical analysis (Kruskal Wallis/Dunn - a=0,05). No statistical difference was found among the groups (p>0,05) for the fracture resistance. The analyze of the hybrid layer was significantly greater in G3 than G2 and G6 (p<0,05). G3, G4 and G5 showed greater bond strength values than G2 and G6 (p<0,05). This study concluded that the al... (Complete abstract click electronic access below) / Mestre
114

Influência da utilização de um adesivo para prótese na satisfação e nos parâmetros cinesiográficos de usuários de próteses totais

Mendoza Marin, Danny Omar [UNESP] 13 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-13Bitstream added on 2014-06-13T18:58:06Z : No. of bitstreams: 1 mendozamarin_do_me_arafo.pdf: 1018438 bytes, checksum: 1f8b0462d02af967b5cf054c1dc81a6d (MD5) / Objetivo: O objetivo deste estudo foi avaliar o efeito da utilização de um adesivo para prótese na satisfação e nos parâmetros cinesiográficos em usuários de próteses totais por meio de um estudo “cross-over”. Material e Métodos: Cinquenta pacientes desdentados receberam novas próteses totais bimaxilares. Após um período de adaptação, os participantes incluídos no estudo receberam uma sequência de tratamento: protocolo 1- utilização do adesivo para prótese durante os primeiros 15 dias, seguida por não utilização do adesivo os próximos 15 dias; protocolo 2- não utilização do adesivo durante os primeiros 15 dias; seguida por utilização do adesivo os próximos 15 dias. Os resultados foram avaliados após 15 dias de cada sequência de tratamento. Um questionário para avaliar a satisfação dos pacientes e um cinesiógrafo para registrar os movimentos mandibulares e o padrão de movimento da prótese total maxilar durante mastigação foram utilizados. O teste de “Wilcoxon” (α=0,05) e o “t-test” de student para amostras pareadas (α=0,05) foram utilizados para comparar o grau de satisfação dos pacientes e os dados cinesiográficos, respectivamente. Resultados: O adesivo para prótese melhorou significativamente a satisfação geral dos participantes (p<0,001). Os registros cinesiográficos mostraram um aumento significativo (1,7mm) no movimento mandibular vertical (p<0,001) e uma menor intrusão (0,3mm) da prótese total superior (p=0,002) durante a mastigação após o uso de adesivo. Conclusão: O uso de adesivo para prótese melhorou a satisfação dos usuários de próteses totais e gerou um aumento no movimento mandibular vertical e uma menor intrusão da prótese total maxilar durante a mastigação / Objectives: The objective of this study was to evaluate the effect of a denture adhesive (DA) on patient satisfaction and kinesiographic parameters of complete denture wearers by a cross-over study. Material and Methods: Fifty edentulous patients received one set of new complete dentures. After an adaptation period, the participants were enrolled in the trial and randomized to receive a sequence of treatment: protocol 1- DA use during the first 15 days, followed by the no use of DA over the next 15 days; protocol 2- no use of DA during the first 15 days, followed by use of DA over the next 15 days. Outcomes were assessed after 15 days of each sequence of treatment. A questionnaire was used to evaluate patients´ satisfaction and a kinesiograph instrument was used to record mandible movements and pattern of maxillary complete denture movement during chewing. Wilcoxon test (α=.05) and a paired sample t-test (α=.05) were used to compare satisfaction levels and kinesiographic data, respectively. Results: The use of DA improved the overall patients´ satisfaction (p<.001). Kinesiographic recordings revealed a significant increase (1.7mm) on vertical mandible movements (p<0,001) during chewing and a lower (.3mm) vertical intrusion of the maxillary complete denture (p=0,002) during chewing after use of DA. Conclusion: The use of a DA in complete dentures wearers improved the patients´ satisfaction and change mandible movements, with increases in vertical mandible movements during chewing and lower intrusion of maxillary complete denture
115

Micromorfologia e resistência da união à dentina decídua tratada com dois sistemas adesivos estudo in vitro

Casagrande, Luciano January 2003 (has links)
O objetivo deste estudo in vitro foi avaliar a interação de dois sistemas adesivos (Scotchbond Multi-Purpose - 3M; Clearfil SE Bond - Kuraray) aplicados à dentina de dentes decíduos, através do ensaio de resistência da união à microtração, e da análise da micromorfologia da interface adesiva. Foram confeccionadas duas cavidades ocluso-proximais padronizadas (tipo slot vertical) na mesial e distal de dezoito molares decíduos hígidos. Cada um dos sistemas adesivos foi aplicado em uma das cavidades do mesmo dente. As cavidades foram restauradas com resina composta (Filtek Z 250 – 3M) pela técnica incremental, sendo cada camada fotopolimerizada por 20 s, utilizando uma fonte de luz visível (XL 2500 - 3M). Os dentes foram armazenados por uma semana em água destilada a 4o C e seccionados no sentido vestíbulo-lingual para análise isolada de cada restauração. Cada uma destas foi seccionada em fatias de 0,7 mm de espessura e, em seguida, efetuou-se uma constrição (1 mm) na região da interface de união (parede axial) para obtenção de uma área adesiva com aproximadamente 0,7 mm2. Os corpos-de-prova foram fixados isoladamente em um dispositivo conectado em uma máquina de ensaio universal (Instron – modelo 4411) e submetidos à tração com velocidade de 0,5 mm/min. As superfícies das secções fraturadas foram avaliadas ao MEV (Jeol –5600 LV) e categorizadas em relação aos padrões de fratura ocorridos. Adicionalmente, superfícies planas contendo a interface de união foram preparadas com lixas de carbureto de silício (granulação 1000) e polimento com pastas de diamante (6, 3, 1 e 0,25 µm). Após desidratação em sílica coloidal em temperatura ambiente por 24 h, as superfícies foram cobertas com liga de ouro e, a micromorfologia da união formada na parede axial das restaurações ocluso-proximais, analisadas ao MEV (Jeol –5600 LV). Os resultados do ensaio de resistência de união foram submetidos à análise estatística utilizando o teste t de student em nível de 5% de significância, e os tipos de fraturas e os aspectos micromorfológicos da interface adesiva submetidos à avaliação descritiva. Os valores médios de resistência de união dos adesivos Scothbond Multi-Purpose (21,84±9,90 MPa) e Clearfil SE Bond (25,19±5,33 MPa) não apresentaram diferenças estatisticamente significantes entre si (p=0,27). A análise do tipo de fratura revelou uma maior quantidade de falhas na região de dentina desmineralizada (G1: SMP) e na porção superior da camada híbrida (G2: CSE). A interface de união, em ambos os grupos, foi caracterizada pela formação da camada híbrida, projeção de prolongamentos resinosos adaptados à dentina e com direcionamento relacionado à disposição dos túbulos dentinários na área da cavidade avaliada.
116

Efeitos a longo prazo da aplicação de adesivos cirúrgicos na perviedade de tubas uterinas de coelhas / The long-term effects of the surgical adhesives application in the patency of rabbits uterine tubes

Rivoire, Henri Chaplin [UNIFESP] January 2006 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:44:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2006 / Objetivo: estudar aspectos morfométricos e da perviedade tubária em coelhas, submetidas à obstrução, transvaginal, com adesivos à base de fibrina, gelatinaresorcina-formaldeído ou cianoacrilato. Métodos: 57 coelhas (n=114 tubas uterinas), albinas, New Zealand, férteis, foram randomizadas em 4 grupos. Grupo I (n=24 tubas uterinas) foi o Grupo Simulado onde só foi realizado cateterismo tubário; Grupo II (n=30 tubas uterinas) recebeu 0,25mL de adesivo de fibrina em cada tuba; Grupo III (n=30 tubas uterinas) recebeu 0,25mL de adesivo de gelatina-resorcina-formaldeído; Grupo IV (n=30 tubas uterinas) teve a colocação de 0,25mL de adesivo de n-butil-2- cianoacrilato. Cada grupo foi redistribuído para observação por 30, 90 e 180 dias, à direita e à esquerda. As coelhas foram acasaladas 2 vezes por semana com machos que tinham acasalado anteriormente e tido gestações. Foi avaliado o peso e as gestações, e após a eutanásia foram analisados: cavidade abdominal para detectar falhas técnicas, perviedade tubária in vitro (Teste de Pressão de Rompimento até 40mmHg), morfometria do diâmetro tubário (cm), da mucosa e do miosalpinge (mm), densidade óptica total da mucosa e processo inflamatório. A análise estatística comparou os lados direito e esquerdo qualitativamente pelo Teste de McNemar e quantitativamente pela Prova de Wilcoxon; os subgrupos de tempo e os grupos foram avaliados qualitativamente pela Generalização do Teste Exato de Fischer e quantitativamente pela Prova de Kruskal-Wallis, e as diferenças foram localizadas pelo Teste de Comparações Múltiplas de Dunn. O nível de significância adotado foi de 0,05 (α ≤ 5%) e valores significantes foram assinalados por asterisco. Resultados: Não houve falhas técnicas detectáveis, todas as tubas dos Grupos I e II estavam pérvias nos tempos do estudo, o que não ocorreu com as tubas dos Grupos III e IV. Ocorreu gestação em 100% animais do Grupo I e em 83,3% do Grupo II (exceto em 5 úteros em 30 dias no Grupo II) e não houve gestação em nenhum dos Grupos III e IV. A análise dos pesos mostrou variação significante no Grupo III, em que todos os animais apresentaram peso final (3.550±550g) menor que o peso inicial (4.050±850g), em decorrência da toxicidade do adesivo de GRF. A morfometria mostrou aumento significativo da mucosa (médias de 0,300-0,430-0,447mm aos 30-90-180 dias respectivamente) e do miosalpinge (médias de 0,442-0,721-0,853mm aos 30-90-180 dias respectivamente) das tubas do Grupo IV que foi relacionado a tentativa de expulsar o adesivo sintético. A densidade óptica total da mucosa mostrou aumento significativo no Grupo III, no subgrupo de 180 dias com média de 0,317, enquanto nos subgrupos de 30 e 90 dias a média foi de 0,300 e 0,287 respectivamente, em virtude da hiperplasia celular desencadeada pela ação lesiva do adesivo de GRF. O processo inflamatório mostrou cronicidade no Grupo III com 180 dias (40% de inflamação leve, 50% de inflamação moderada e 10% de inflamação acentuada). Conclusões: O adesivo de fibrina não obstruiu as tubas, foi absorvido e não produziu alterações morfológicas nas tubas. O adesivo de GRF obstruiu as tubas, foi absorvido e produziu alterações morfológicas importantes na mucosa e miosalpinge das tubas. O adesivo de n-butil-2-cianoacrilato obstruiu as tubas impedindo a gestação, não foi absorvido e não provocou alterações qualitativas relevantes na mucosa das tubas uterinas, embora tenha alterado as espessuras da mucosa e miosalpinge. / Objective: to morfometrics aspects study and of the patency of rabbits uterine tubes, submitted to the obstruction, by transvaginal approach, with stickers to the fibrin, gelatin-resorcin-formaldehyde or cyanoacrylate. Methods: 57 rabbits (n=114 uterine tubes), albino, New Zealand, fertile, were randomized in 4 groups. Group I (n=24 uterine tubes) it was the Simulated Group where catheterization only was accomplished; Group II (n=30 uterine tubes) it received 0,25mL of fibrin glue in each tube; Group III (n=30 uterine tubes) it received 0,25mL of gelatin-resorcin-formaldehyde glue; Group IV (n=30 uterine tubes) had the placement of 0,25mL of n-butil-2-cyanoacrylate glue. Each group was subdivided for observation for 30, 90 and 180 days, and the right and the left. The rabbits were coupled 2 times a week with males that had coupled previously and had gestations. It was evaluated the weight and the gestations, and after the euthanasia they were analyzed: abdominal cavity to detect technical flaws, tubal patency in vitro (Test of Pressure of Breaking up to 40mmHg), morfometrics of the tubal diameter (cm), of the mucous membrane and of the miosalpinge (mm), density optical total of the mucous membrane and lawsuits. The statistical analysis compared the right and left sides qualitatively for the Test of McNemar and quantitatively for the Proof of Wilcoxon; the subgroups of time and the groups were appraised qualitatively for the Generalization of Fischer's Exact Test and quantitatively for the Proof of Kruskal-Wallis, and the differences were located for the Test of Multiple Comparisons of Dunn. Was the level of adopted significance of 0,05 (α ≤ 5%) and were significant values marked for asterisk. Results: There were not technical flaws detected, all of Groups I and II were tubal patency in the times of the study, what didn't happen with the tubes of the Groups III and IV. It happened gestation in 100% animals of the Group I and in 83,3% of the Group II (except in 5 uterus in 30 days in the Group II) and there was not gestation in none of the Groups III and IV. The analysis of the weights showed significant variation in the Group III, in that all animals presented smaller final weight (3.550±550g) than the initial weight (4.050±850g), due to the toxicity of the GRF glue. The morfometry showed significant increase of the mucous membrane (means of 0,300-0,430-0,447mm averages to the 30-90-180 days respectively) and of the miosalpinge (means of 0,442-0,721-0,853 averages to the 30-90-180 days respectively) of the tubes of the Group IV that it was related the attempt of expelling the synthetic glue. The density optical total of the mucous membrane showed significant increase in the Group III, in the subgroup of 180 days with average of 0,317, while in the subgroups of 30 and 90 days the average was of 0,300 and 0,287 respectively, because of the cellular hyperplasy unchained by the harmful action of the GRF glue. The lawsuits showed chronicity in the Group III with 180 days (40% of light inflammation, 50% of moderate inflammation and 10% of accentuated inflammation). Conclusions: The fibrin glue didn't obstruct the tubes, it is absorbed and it doesn't produce morphologic alterations in the tubes. The GRF glue obstructed the tubes, it was absorbed and it produced important morphologic alterations in the mucous membrane and miosalpinge of the tubes. The n-butil-2-cyanoacrylate glue obstructed the tubes impeding the gestation, it was not absorbed and it didn’t provoke qualitative alterations in the mucous membrane of the uterine tubes, although it has altered the thickness of the mucous membrane and miosalpinge. / BV UNIFESP: Teses e dissertações
117

Influência de diferentes estratégias adesivas e do tipo do isolamento do campo operatório (absoluto versus relativo) no desempenho clínico de restaurações com resina composta em lesões cervicais não cariosas

Cunha, Eduardo Marinho Daudt da 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T07:40:23Z (GMT). No. of bitstreams: 1 284314.pdf: 7573505 bytes, checksum: da95b211835f64a112ad52deec6a3efd (MD5) / Este estudo teve como objetivo avaliar o desempenho clínico de lesões cervicais não cariosas (LCNC) restauradas com diferentes estratégias adesivas: condicionamento ácido e autocondicionante, e comparar se o tipo do isolamento do campo operatório: absoluto ou relativo pode influenciar na durabilidade das restaurações por um período de 180 dias. Cento e quarenta lesões foram selecionadas em 38 pacientes de acordo com os critérios de inclusão/exclusão previamente estabelecidos, e distribuídas em quatro grupos (n=35) : G1 e G2: condicionamento ácido total e Adper Single Bond 2. G3 e G4: autocondicionante Adper SE Plus. O isolamento absoluto foi utilizado alternadamente em todo os grupos. Todos os procedimento restauradores foram realizados com a resina composta Z 350 por meio da técnica incremental, por um único operador. As 140 restaurações foram avaliadas pelo método direto USPHS modificado, por dois examinadores previamente calibrados, em 4 períodos distintos: imediato (até 24hs após a conclusão do procedimento restaurador) 7, 30, 180 dias. Os dados foram submetidos ao teste estatístico de McNemar para verificar possíveis alterações no índice Alfa dentro dos grupos em cada momento de avaliação. Para analisar a associação entre os grupos, foi utilizado o teste do Qui-quadrado, com nível de significância de 5%. Os resultados revelam que as duas estratégias adesivas promoveram uma queda efetiva na sensibilidade durante todo o período avaliador. Não houve diferença estatística para as estratégias adesivas ou as técnicas de isolamento, salvo o critério de descoloração marginal, onde 4 restaurações do G4 apresentaram escores bravo.
118

Influência de agentes dessensibilizantes na resistência de união de sistemas adesivos à dentina

Czernay, João Adolfo January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-22T19:39:13Z (GMT). No. of bitstreams: 1 254669.pdf: 1680539 bytes, checksum: 7a7cbfb109d73b5861a00e7978c2228c (MD5) / A substituição de restaurações de amálgama por restaurações adesivas estéticas resulta muitas vezes em sensibilidade pós-operatória. Os dessensibilizantes, portanto, vem sendo indicados e utilizados no protocolo de restaurações adesivas estéticas, o que pode afetar a resistência de união dos sistemas adesivos à dentina, razão desta investigação. Cilindros de resina composta foram unidos à superfície dentinária através da técnica adesiva. Os espécimes foram distribuídos em quatro grupos e submetidos à uma força de cisalhamento, 24h após a sua confecção. Concluiu-se que quando o dessensibilizante Gluma Desensitizer foi aplicado, os valores de resistência de união à dentina aumentaram significativamente (p=0.0322), o que não ocorreu com o dessensibilizante Bis Block, em que foram encontrados baixos valores de resistência de união (9,98MPa).
119

Resistência de união ao microcisalhamento de sistemas adesivos autocondicionantes de 2 passos : efeito de novas formulações de dentifrícios em substrato dentinário normal e hipermineralizado artificialmente /

Ohata, Gabriela. January 2017 (has links)
Orientador: Edson Alves de Campos / Resumo: Um dos principais responsáveis pelo sucesso nos tratamentos restauradores são os sistemas adesivos, uma técnica que tem ganhado grande atenção na atualidade é a que faz uso de sistemas autocondicionantes. O objetivo deste trabalho foi avaliar a resistência de união de diferentes sistemas adesivos autocondicionantes de 2 passos, com graus de acidez distintos, frente ao tratamento prévio com novas formulações de dentifrícios, em substrato dentinário normal e hipermineralizado artificialmente. Cento e vinte oito dentes incisivos inferiores bovinos hígidos foram selecionados e aleatoriamente divididos em 2 categorias de acordo com o tipo de dentina: normal (N=64) e hipermineralizada (N=64). Os dentes tiveram sua superfície vestibular desgastada para expor superfície dentinária plana e lixados para a exposição de uma superfície dentinária uniforme e padronizada. Os dentes foram aleatoriamente divididos em dois diferentes grupos, de acordo com o tipo de adesivo autocondicionante utilizado: Clearfil SE Bond (grupo C) (n=32) e AdheSE (grupo A) (n=32). Foram então aleatoriamente divididos em quatro subgrupos, de acordo com o tipo de dentifrício aplicado ou a ausência deste. Os subgrupos são: (1) Condicionamento convencional - aplicação do sistema adesivo autocondicionante segundo recomendações do fabricante (n1=8) (2) Escovação da superfície dentinária com dentifrício Colgate Pró-alívio (Pro-Argin®, Palmolive) + aplicação do sistema adesivo autocondicionante segundo ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The major contributor to the success in restorative treatments are adhesive systems, currently a technique that has gained much attention are those that makes use of self-etching systems. The objective of this study was to evaluate the bond strength of different 2 - step self - etching adhesive systems, with different acidity levels, compared to previous treatment with new dentifrice formulations, in normal and artificially hypermineralized dentin substrates. One hundred and twenty eight healthy bovine inferior incisor teeth were selected and randomly divided into 2 categories according to the type of dentin: normal (N = 64) and hypermineralized (N = 64). The teeth had their vestibular surface worn to expose a flat dentin surface and sanded to expose a uniform and standardized dentin surface. The teeth were randomly divided into two different groups, according to the type of self-etching adhesive system used: Clearfil SE Bond (group C) (n = 32) and AdheSE (group A) (n = 32). They were randomly divided into four subgroups, according to the type of dentifrice applied or the absence of dentifrice. The subgroups are: (1) Conventional conditioning - application of the self-etching adhesive system according to the manufacturer's recommendations (n1 = 8); (2) Brushing the dentine surface with Colgate Pro-Relief (Pro-Argin®, Palmolive) + application of self-etching according to the manufacturer's recommendations (n2 = 8); (3) Brushing the dentin surface with Biorepair (Dr.Kurt Wolff, Bielefeld, Germany) + application of self-etching adhesive system according to the manufacturer's recommendations (n3 = 8); (4) Brushing the dentin surface with Regenerate Enamel Science (Unilever) + application of selfetching adhesive system according to the manufacturer's recommendations (n4 = 8). Transparent cylindrical matrices were positioned on each dentin surface treated with the adhesives tested, filled with... (Complete abstract electronic access below) / Mestre
120

Avaliação in vitro da microinfiltração marginal em cavidades submetidas ao tratamento com laser de Er:YAG e restauradas com diferentes resinas compostas e sistemas adesivos

Noya, Márcia Sepúlveda 28 May 2013 (has links)
Submitted by Hiolanda Rêgo (hiolandar@gmail.com) on 2013-05-24T20:40:57Z No. of bitstreams: 1 Tese_ODONTO_ Márcia Sepúlveda Noya.pdf: 1549034 bytes, checksum: 4572a39768a459dd219cc5ad280e647e (MD5) / Approved for entry into archive by Flávia Ferreira(flaviaccf@yahoo.com.br) on 2013-05-28T16:53:55Z (GMT) No. of bitstreams: 1 Tese_ODONTO_ Márcia Sepúlveda Noya.pdf: 1549034 bytes, checksum: 4572a39768a459dd219cc5ad280e647e (MD5) / Made available in DSpace on 2013-05-28T16:53:55Z (GMT). No. of bitstreams: 1 Tese_ODONTO_ Márcia Sepúlveda Noya.pdf: 1549034 bytes, checksum: 4572a39768a459dd219cc5ad280e647e (MD5) / O objetivo desta pesquisa foi avaliar a microinfitração, através de lupa estereoscópica, em cavidades de Classe V, condicionadas por três métodos: 1) com ácido fosfórico a 35%, 2) com laser de Er:YAG, em freqüência única de 3 Hz e energias distintas, 100 mJ e 200 mJ e 3) irradiação com laser de Er:YAG nos parâmetros acima descritos + condicionamento ácido. Em seguida os dentes foram restaurados com resina composta microhíbrida Esthet-X (Dentsply) e Z 250 (3M) e diferentes sistemas adesivos, um com solvente a base de acetona (Prime & Bond) e o outro a base de álcool e água (Single Bond). Foram utilizados 100 dentes humanos e os preparos foram realizados na face vestibular com extensão cervical a 1-2 mm além da junção amelocementária. Depois de restaurados os dentes foram submetidos a termociclagem em água a 5ºC ± 2º C e 55ºC ± 2º C, com 5 segundos de intervalo e 30 segundos de imersão, num total de 500 ciclos e, em seguida, imersos em solução aquosa de nitrato de prata 50% por 2 horas, seguida da imersão em solução reveladora. Os dentes foram incluídos em resina acrílica e seccionados no sentido vestíbulo-lingual, dividindo assim a restauração em duas porções uma mesial e a outra distal. A avaliação da microinfiltração, em esmalte e cemento foi feita segundo escores de zero a três. Os resultados foram submetidos ao Teste de Kruskal-Wallis e a prova de Mann-Whitney, através dos quais foi possível concluir que, em esmalte, os grupos condicionados com ácido e aqueles que foram irradiados e em seguida condicionados e restaurados com o sistema adesivo a base de água apresentam ausência de microinfiltração, sendo os grupos apenas irradiados com laser de Er:YAG e restaurados com o sistema adesivo a base de acetona, os que mostraram os maiores valores de microinfiltração. Em cemento, os menores graus de microinfiltração foram observados nos dentes condicionados + irradiados + adesivo com solvente a base de água. Concluiu-se que tanto em esmalte quanto em cemento, o emprego do ácido fosfórico, associado ou não a irradiação laser, mostrou-se efetivo na diminuição da microinfiltração. Em esmalte, o sistema adesivo a base de água apresentou um melhor desempenho quando comparado aos adesivos a base de acetona. No entanto, em cemento, os diferentes solventes mostraram comportamento semelhante entre eles. Quando avaliou-se a microinfiltração em relação a margem cavitária, observouse que esta foi inferior em esmalte quando comparada ao cemento. / Salvador

Page generated in 0.0473 seconds