• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 24
  • 10
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de tecnologia de biofabricação com laser infravermelho para recobrimento de próteses articulares com hidrogel / Development of biofabrication technology with Infrared laser to coating of articular prostheses with hydrogel

Passos, Marcele Fonseca, 1986- 19 August 2018 (has links)
Orientador: Passos, Marcele Fonseca / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-19T02:23:46Z (GMT). No. of bitstreams: 1 Passos_MarceleFonseca_M.pdf: 15093576 bytes, checksum: fc209e9f43b60067bf5b99f169881ea4 (MD5) Previous issue date: 2011 / Resumo: Na área dos materiais, um campo em crescente expansão é o desenvolvimento de hidrogéis poliméricos para aplicações biomédicas. Entre a grande classe de hidrogéis poliméricos estudados, o poli 2-hidróxi etil metacrilato (pHEMA) recebe especial atenção, devido a sua biocompatibilidade, alta hidrofilicidade e fácil preparação. Para aplicação como substituinte da cartilagem articular natural em próteses articulares, as quais, normalmente apresentam como principal componente (substrato) o polietileno de ultra alto peso molecular (PEUAPM), a adesão do sistema (hidrogel - substrato) ainda é um parâmetro a ser avaliado. Modificações adequadas no material e considerações de projeto, no entanto, podem melhorar a aderência do conjunto, via embricamento mecânico. Dentro de um grupo multidisciplinar e em ascensão, Instituto Nacional de C&T em Biofabricação - BIOFABRIS, este projeto, teve como objetivo, desenvolver novos biomateriais, usando técnicas de engenharia para obtenção de dispositivos biomédicos (próteses e órteses ortopédicas). Foi desenvolvida uma tecnologia de biofabricação visando melhorar as propriedades mecânicas dos hidrogéis de pHEMA, bem como obter uma adesão adequada entre este polímero e a superfície articular artificial, a fim de minimizar o desgaste sofrido pelos componentes que constituem os dispositivos ortopédicos, um dos principais fatores que geram sua falência. Usando a técnica de biofabricação, foi possível obter hidrogéis de pHEMA desde a simulação do produto até a caracterização final, para aplicações específicas: cartilagem articular artificial, foco principal da dissertação; e, como cartilagem reconstrutiva, atuando como suporte ao crescimento de células (hidrogéis porosos). A avaliação do mecanismo de polimerização e reticulação do pHEMA, o calor específico e a condutividade térmica da solução do 2-hidróxi etil metacrilato (HEMA) foram obtidos via técnica de Calorimetria Exploratória Diferencial. Tais parâmetros serviram de subsídio para a simulação computacional, a qual permitiu estimar os parâmetros do processo de reticulação do pHEMA, como potência do laser a 30 W e tempo reacional de 120 segundos, na temperatura de 399 K. As propriedades térmicas, como temperatura de transição vítrea e degradação, apresentaram valores similares aos dados encontrados na literatura, na faixa de 109 e 118 ºC, e na faixa de 354 e 376 ºC, respectivamente. Os resultados obtidos do coeficiente de atrito do par tribológico PEUAPM-pHEMA apresentaram valores altos, contudo, a tecnologia de biofabricação desenvolvida neste projeto, mostrou-se uma importante ferramenta para a obtenção de biomateriais para aplicações diversificadas / Abstract: In the materials field, a rapidly expanding field is the development of polymeric hydrogels for biomedical applications. Among the large class of polymeric hydrogels studied, poly 2-hydroxy ethyl methacrylate (pHEMA) receives special attention. For application as replacements of natural articular cartilage in articular prostheses, which usually present as a main component (substrate) the polyethylene of ultra high molecular weight (UHMWPE), the adhesion of system (hydrogel - substrate) is still a parameter to be evaluated. Appropriate modifications in the material and design considerations, however, can improve the adhesion of the set by embrication mechanic. Within a multidisciplinary group and on the rise, National Institute of C & T in Biofabrication -BIOFABRIS, this project aims to develop new biomaterials using engineering techniques for obtaining biomedical devices (prostheses and orthoses, orthopedic). It was developed a technology aiming to both improve the mechanical properties of pHEMA hidrogel as well as to obtain proper adhesion between this polymer and the artificial articular surface in order to minimize the wear suffered by the components that constitute the orthopedic devices, one of the main factors that cause bankruptcy. Using the technique of biofabrication was possible to obtain hydrogels pHEMA from the simulation of the product until the final characterization, for specific applications: artificial articular cartilage, the main focus of the dissertation, and as a reconstructive cartilage, acting as a support cell growth (porous hydrogels). The evaluation of the mechanism of polymerization and crosslinking of pHEMA, the specific heat and thermal conductivity of the solution of 2-hydroxy ethyl methacrylate (HEMA) were obtained by the technique of Differential Scanning Calorimetry. These parameters served as input to the computer simulation, which allowed to estimate the process parameters of pHEMA crosslinking, such as laser power 30 W and the reaction time of 120 seconds at a temperature of 399 K. The thermal properties and glass transition temperature and degradation, showed values similar to those found in the literature, to know, in the range of 109 and 118 °C, and in the range of 354 and 376 °C, respectively. The obtained results of the friction coefficient for the tribological pair UHMWPE-pHEMA have demonstrated high values, however, the biofabrication technology developed in this project, was important a tool for obtaining biomaterials for different applications / Mestrado / Desenvolvimento de Processos Químicos / Mestre em Engenharia Química
2

Impacto do uso da aspirina na incidência de eventos tromboembólicos após implante de bioprótese valvar cardíaca na doença reumática crônica / Programa de Pós-Graduação em Medicina e Saúde

Durães, André Rodrigues January 2013 (has links)
p. 1-50 / Submitted by Antonio Geraldo Couto Barreto (ppgms@ufba.br) on 2013-10-03T12:51:10Z No. of bitstreams: 1 Tese Doutorado André Durães.pdf: 553280 bytes, checksum: 959d5f12a34df56f7195e3b230138b7a (MD5) / Approved for entry into archive by Patricia Barroso(pbarroso@ufba.br) on 2013-10-03T17:55:05Z (GMT) No. of bitstreams: 1 Tese Doutorado André Durães.pdf: 553280 bytes, checksum: 959d5f12a34df56f7195e3b230138b7a (MD5) / Made available in DSpace on 2013-10-03T17:55:05Z (GMT). No. of bitstreams: 1 Tese Doutorado André Durães.pdf: 553280 bytes, checksum: 959d5f12a34df56f7195e3b230138b7a (MD5) Previous issue date: 2013 / Introdução - Ainda existem controvérsias em relação a melhor estratégia de terapia antitrombótica nos três meses iniciais de pós-operatório de implante de bioprótese valvar cardíaca. Assim, os autores consideram relevante determinar a incidência contemporânea de episódios de isquemia cerebral nos meses iniciais (primeiros 90 dias de pós-operatório), e realizar uma comparação entre a aspirina isolada (ASA) versus a não-terapia antiplaquetária no mesmo contexto. Métodos e Resultados - Entre o período de janeiro de 2010 a julho de 2012, consecutivamente todos pacientes reumáticos com ritmo sinusal basal, que realizaram a substituição da válvula mitral, e ou aórtica, por bioprótese (pericárdio bovino), foram incluídos neste estudo de coorte prospectivo, totalizando 184 pacientes. O desfecho primário avaliado foi a ocorrência de eventos embólicos. Nos primeiros 30 dias, três eventos isquêmicos cerebrais foram observados em pacientes do grupo ASA (5,2%), em comparação com dois eventos em pacientes sem terapia ASA (1,7%), RR = 3,18, 95% IC 0,5-19,6; P = 0,33. Entre 31 e 90 dias do pós-operatório, nenhum paciente apresentou episódios de embolia cerebral ou periférica. A sobrevida livre de eventos embólicos, sangramentos e a sobrevida geral não foram estatisticamente significativas entre os grupos ASA e não ASA. Conclusões - Constatou-se uma baixa incidência de eventos embólicos durante os primeiros 90 dias de pós-operatório de troca valvar por bioprótese envolvendo a posição mitral, e uma ainda menor para mesma situação para troca aórtica isolada. O uso da aspirina não influenciou de maneira significativa na redução de episódios tromboembólicos. / Salvador
3

Influência de agentes dessensibilizantes na resistência de união de sistemas adesivos à dentina

Czernay, João Adolfo January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-22T19:39:13Z (GMT). No. of bitstreams: 1 254669.pdf: 1680539 bytes, checksum: 7a7cbfb109d73b5861a00e7978c2228c (MD5) / A substituição de restaurações de amálgama por restaurações adesivas estéticas resulta muitas vezes em sensibilidade pós-operatória. Os dessensibilizantes, portanto, vem sendo indicados e utilizados no protocolo de restaurações adesivas estéticas, o que pode afetar a resistência de união dos sistemas adesivos à dentina, razão desta investigação. Cilindros de resina composta foram unidos à superfície dentinária através da técnica adesiva. Os espécimes foram distribuídos em quatro grupos e submetidos à uma força de cisalhamento, 24h após a sua confecção. Concluiu-se que quando o dessensibilizante Gluma Desensitizer foi aplicado, os valores de resistência de união à dentina aumentaram significativamente (p=0.0322), o que não ocorreu com o dessensibilizante Bis Block, em que foram encontrados baixos valores de resistência de união (9,98MPa).
4

Próteses tubulares de biopolímero do melaço de cana-de-açúcar utilizadas na reconstrução de veias femorais de cães

SILVA, Daniella Maria de Souza e 02 February 2015 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-10-09T20:44:15Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Daniella Maria de Souza e Silva.pdf: 2003443 bytes, checksum: ecc20046b6d4c72989c76720103f4b7f (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-11-21T19:27:53Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Daniella Maria de Souza e Silva.pdf: 2003443 bytes, checksum: ecc20046b6d4c72989c76720103f4b7f (MD5) / Made available in DSpace on 2018-11-21T19:27:54Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Daniella Maria de Souza e Silva.pdf: 2003443 bytes, checksum: ecc20046b6d4c72989c76720103f4b7f (MD5) Previous issue date: 2015-02-02 / Introdução: As cirurgias de reconstrução venosa representam um desafio aos cirurgiões vasculares, pois as veias perdem sua forma cilíndrica, devido às características da anatomia e fisiologia do sistema venoso. A evolução no processo de fabricação de produtos de biopolímero de cana-de-açúcar, resultou na produção de tubos, permitindo sua aplicação na área de cirurgia vascular como enxerto tubular venoso. Objetivo: Avaliar a resposta clínica funcional e de biointegração de próteses tubulares de biopolímero da cana-de-açúcar na reconstrução de veias femorais em cães. Métodos: Oito cães foram submetidos a reconstrução venosa com a prótese tubular de biopolímero de cana de açúcar à esquerda e veia autóloga à direita. No período pós-operatório, os animais foram avaliados através do exame clínico e Dopler fluxometria das veias femorais. Após 360 foram submetidos a flebografia e a uma nova intervenção cirurgica para a retirada dos segmentos das veias femorais, esquerda e direita, contendo segmento de 1 cm das veias nativas proximal e distal, a partir dos enxertos de reconstrução. Os materias foram enviados para estudo histopatológico. Resultados: No período de 360 dias de observação, os cães não apresentaram sinais clínicos de hemorragia, hematoma e infecção na ferida operatória. Um cão apresentou, na região inguinal esquerda, dilatação venosa superficial. Foi encontrada trombose em cinco (62,5%) enxertos do biopolímero de cana-de-açúcar e um (12,5%) de veia autóloga. Conclusão: A prótese de biopolímero de cana-de-açúcar pode ser utilizada como enxerto tubular para revascularização de veias femorais em cães. / Introduction: Venous reconstruction surgeries present a challenge to vascular surgeons because the veins lose their cylindrical shape due to the characteristics of the anatomy and physiology of the venous system. The evolution in the production process of sugarcane biopolymer products resulted in the production of tubes, allowing its application in the area of vascular surgery as a venous tubular graft. Objective: To evaluate the functional and biointegration response of tubular biopolymer prostheses of sugarcane in the reconstruction of femoral veins in dogs. Methods: Eight dogs were submitted to venous reconstruction with the tubular biopolymer prosthesis of sugar cane to the left and autologous vein to the right. In the postoperative period, the animals were evaluated through clinical examination and dopler flowmetry of the femoral veins. After 360 were submitted to phlebography and a new surgical intervention for the removal of segments of the femoral veins, left and right, containing 1 cm segment of the proximal and distal native veins, from the reconstruction grafts. Subjects were sent for histopathological study. Results: During the 360-day observation period, the dogs did not present clinical signs of hemorrhage, hematoma and infection in the surgical wound. A dog had superficial venous dilatation in the left inguinal region. Thrombosis was found in five (62.5%) grafts of the biopolymer of sugarcane and one (12.5%) of autologous vein. Conclusion: The sugar cane biopolymer prosthesis can be used as a tubular graft for revascularization of femoral veins in dogs.
5

Análise da efetividade da descelularização como método anticalcificante em próteses valvares de pericárdio bovino fixado em glutaraldeído : estudo experimental em ovinos / Claudinei Collatusso ; orientador, Francisco Diniz Affonso da Costa ; co-orientador, João Gabriel Roderjan

Collatusso, Claudinei January 2010 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2010 / Bibliografia: f.49-54 / Introdução: o pericárdio bovino fixado em glutaraldeído é utilizado na confecção de próteses valvares cardíacas, porém sofre processo de degeneração e calcificação. Vários métodos foram empregados com a finalidade de evitar a calcificação. Objetivo: avali / Introduction: bovine pericardium preserved into glutaradehyde is used in cardiac bioprosthesis, however a process of degeneration and calcification is identified. Many treatments are used to try avoid this calcification. Objective: to analyze the descelul
6

Substituição do tronco da artéria pulmonar em carneiros, utilizando heteroenxerto tubular valvado, preservado em L-HydroR / Replacing the body of pulmonary artery in sheep using tubular graft valved bovine pericardium with non aldehydic preservation

Souza, Helmgton José Brito de [UNIFESP] January 2011 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:45:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2011 / Introdução: As biopróteses valvares cardíacas estão relacionadas a eventos tromboembólicos, infecciosos e degenerativos. Seu desgaste é atribuído principalmente à desnaturação do colágeno. O glutaraldeído, método predominante de preservação de biopróteses, favorece o processo de calcificação e limita sua durabilidade. Diversas técnicas tentam conter o processo degenerativo das biopróteses. Objetivos: Avaliar o processo de calcificação, in vivo, de heteroenxertos pulmonares valvados, preservados em meios não aldeídico (L-HydroR). Métodos: 17 carneiros foram submetidos à substituição do tronco da artéria pulmonar por enxerto tubular valvado de pericárdio bovino. Os animais foram distribuídos em dois grupos: Grupo L-HydroR (teste / n=14) e Grupo Glutaraldeído (controle / n=3). Cerca de 150 dias pós implante, foram realizadas angiografia, medidas hemodinâmicas e sacrifício. Os animais foram necropsiados e as próteses submetidas a estudo anátomo-patológico, avaliação radiológica e dosagem do cálcio por espectofotometria de absorção atômica. A análise estatística foi obtida através dos testes exato de Fisher, T de Student ou Mann-Whitney (significância: 5%). Resultados: O desempenho hemodinâmico e angiográfico das próteses testadas foi semelhante nos dois grupos. A avaliação radiológica, a macroscopia, a microscopia e a dosagem de cálcio por espectrofotometria de absorção atômica mostraram maior calcificação nas próteses do Grupo Glutaraldeído, quando comparadas às próteses do Grupo L-HydroR (p=0,001). 07 animais do Grupo L-HydroR (50%) apresentaram aderência das cúspides à parede do tubo (p=0,228). Conclusões: As próteses preservadas em L-HydroR mostraram-se mais resistentes à calcificação, quando comparadas às preservadas em Glutaraldeído. / Introduction: The cardiac bioprostheses are related to thromboembolic events, infectious and degenerative diseases. Wear is mainly attributed to the denaturation of collagen. Glutaraldehyde, the predominant method of preservation of bioprostheses, favors the calcification process and limits their durability. Several techniques try to contain the degenerative process of bioprostheses. Objectives: To evaluate the process of calcification in vivo pulmonary valve heterografts preserved in non-aldehydic (L-HydroR). Methods: 17 sheep underwent replacement of the pulmonary artery valved tubular grafts of bovine pericardium. The animals were divided into two groups: Group L-HydroR (test / n = 14) and Group Glutaraldehyde (control / n = 3). About 150 days after implantation, angiography was performed, hemodynamic measurements and sacrifice. The mice were sacrificed and the prostheses subjected to a pathological study, radiological evaluation and measurement of calcium by atomic absorption spectrophotometry. Statistical analysis was obtained through the Fisher's exact test, Student's t or Mann-Whitney test (significance: 5%). Results: The angiographic and hemodynamic performance of prostheses tested was similar in both groups. Radiological evaluation, the macroscopic and microscopic measurement of serum calcium by atomic absorption spectrophotometry showed increased calcification of the prosthesis Glutaraldehyde Group, when compared to L-HydroR Group prosthesis (p =0.001). 07 animals in Group L-HydroR (50%) had adherence of the leaflets to the wall of the tube (p = 0.228). Conclusions: Prostheses preserved in LHydroR were more resistant to calcification when compared with Glutaraldehyde preserved. / BV UNIFESP: Teses e dissertações
7

Membrana de biopolímero de cana-de-açúcar como remendo em arterioplastias femorais em cães

Marques Lins, Esdras January 2007 (has links)
Made available in DSpace on 2014-06-12T16:28:46Z (GMT). No. of bitstreams: 2 arquivo5646_1.pdf: 2698539 bytes, checksum: 19e730db7e32fff977ea21642687c458 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2007 / Objetivo: O objetivo deste estudo foi avaliar a utilização da membrana de biopolímero de cana-de-açúcar como remendo em arterioplastias femorais em cães. Material e método: Oito cães adultos mestiços foram anestesiados por via endovenosa com cloridrato de cetamina na dose de 2,5 mg / Kg e brometo de pancurônio na dose de 0,2 mg / Kg, após indução com tiopental sódico na dose de 12,5 mg / Kg. Foi realizada tricotomia das regiões inguinais e a seguir procedeu-se a velocimetria Doppler percutânea das artérias femorais direita e esquerda para controle pré-operatório. Sob condições de assepsia e anti-sepsia os cães foram submetidos à dissecção das artérias femorais seguida da medida do diâmetro arterial e de uma arteriotomia longitudinal com retirada de um fragmento elíptico da parede arterial medindo 1,5 cm por um terço do diâmetro da artéria. Para a correção do defeito da parede arterial, os animais foram submetidos à arterioplastia femoral bilateral com remendos da membrana de biopolímero de cana-de-açúcar no lado esquerdo (grupo experimental) e de PTFE expandido (grupo controle) no lado direito. As suturas foram contínuas com fio de prolene ® 7.0. As membranas utilizadas como remendos são constituídas de um biopolímero obtido por síntese bacteriana a partir do melaço de cana-de-açúcar, produzidas na Estação Experimental de Cana-de-Açúcar de Carpina da Universidade Federal Rural de Pernambuco e processadas para aplicação como prótese cirúrgica no Núcleo de Cirurgia Experimental do Centro de Ciências da Saúde da Universidade Federal de Pernambuco. Na primeira semana pós-operatória os cães foram submetidos a avaliação clínica diária e semanal a partir do oitavo dia. A avaliação clínica consistiu no exame dos pulsos femorais, na avaliação da marcha e na observação da presença de tumor pulsátil, hematoma ou hemorragia e infecção da ferida operatória. Após 180 dias das arterioplastias, sob anestesia geral, foi realizada tricotomia das regiões inguinais e abdominal e procedeu-se nova fluxometria Doppler percutânea das artérias femorais . Os animais foram submetidos à dissecção das artérias femorais, medido o diâmetro arterial e realizada velocimetria Doppler trans-operatória em pontos proximal e distal à arterioplastia. A seguir foi realizada laparotomia e exposição da aorta abdominal para acesso arteriográfico. Através da velocimetria Doppler e da arteriografia foi pesquisada a ocorrência de trombose, aneurisma e falso-aneurisma. Os segmentos das artérias femorais com os remendos foram retirados para estudo histopatológico e os animais foram mortos com dose tóxica de anestésico. Resultados: No período de avaliação de 180 dias, nos dois grupos, não foram observados casos de infecção da ferida operatória , dilatação, ruptura, falso-aneurisma ou trombose. Nos dois grupos foi encontrada uma resposta inflamatória crônica com neutrófilos e linfócitos. Nas superfícies externa e interna dos remendos foi encontrada fibrose. No grupo controle ocorreu invasão dos remendos de e-PTFE por fibroblastos. Conclusões: Com base nos resultados obtidos com o modelo experimental utilizado, conclui-se que a membrana de biopolímero de cana-de-açúcar pode ser utilizada como remendo em arterioplastias femorais em cães
8

Estudo experimental de escoamento pulsátil através de biopróteses valvulares cardíacas mitrais a partir do desenvolvimento de um simulador do lado esquerdo do coração. / Experimental study pulsatile flow through mitral heart bioprosthesis based on the development of a left human heart cardiac simulator.

Bazan, Ovandir 26 March 2014 (has links)
Uma vez que a maioria das complicações relacionadas ao funcionamento das próteses de válvulas cárdicas é devida aos distúrbios de escoamento, a sua caracterização hidrodinâmica é um auxílio útil no projeto de novas válvulas. Simulações do escoamento pulsátil através de próteses de válvulas cardíacas começaram há cerca de 60 anos, por meio do desenvolvimento de diferentes simuladores cardíacos, melhorando a interpretação dos resultados clínicos. Para o presente estudo, um simulador cardíaco foi desenvolvido completamente na Escola Politécnica da Universidade de São Paulo, no Departamento de Engenharia Mecânica, para estudar o fluxo através de próteses mitrais e aórticas. A sua concepção é baseada na geometria e na fisiologia do lado esquerdo do coração humano, no estado da arte desses simuladores e na norma ISO 584:2010. Neste trabalho, o simulador cardíaco desenvolvido foi aplicado para estudar experimentalmente o fluxo pulsátil através de próteses cardíacas mitrais biológicas de pericárdio bovino. Para tanto, após a validação do simulador para algumas freqüências cardíacas, as biopróteses foram submetidas a ensaios de velocimetria não invasiva, por meio de um equipamento Particle Image Velocimetry (PIV). Os experimentos, que se concentraram principalmente logo após o começo da diástole, mostraram qualitativamente uma diferença significativa no escoamento intraventricular em função de dois posicionamentos das biopróteses, defasadas entre si de 180º no sentido do seu eixo longitudinal. Além disso, produziram significativas mudanças no escoamento próximo à prótese aórtica considerada. Com a continuidade deste estudo, os resultados poderão induzir a um dado procedimento clínico. / Since most complications related to the operation of prosthetic heart valves are due to disturbances of flow, their hydrodynamic characterization is a useful aid in the design of new prostheses. Simulations of pulsatile flow in cardiac prostheses began nearly 60 years ago, through the development of different mock human circulatory systems, improving the clinical results interpretation. A complete design of a cardiac simulator was developed at Polytechnic School of USP, Mechanical Engineering Department, to study mitral and aortic prosthetic heart valves. The simulator design is based on the both geometry and physiology of the left side of the human heart, on state-of-art studies and also considering the ISO 584:2010 standard. The cardiac simulator was applied to pulsatile flow testing of bovine pericardium mitral prosthetic valves. For this, after the cardiac simulator validation for some heart rates, the bioprostheses were assayed by noninvasive velocimetry technics, i.e., a Particle Image Velocimetry (PIV) system. The testing, which mainly were focused on just after the beginning of diastole, qualitatively have showed a significant difference in the intraventricular flow according two different positions for the bioprostheses, dephased of 180° in the direction of their longitudinal axis. Moreover, they produced significant changes in flow close to the aortic prosthesis considered. Future works may lead to a particular medical procedure.
9

Restauração da parede torácica em cães com cartilagem auricular suína tratada pela glicerina

Faro, André de Mattos [UNESP] 05 November 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-11-05Bitstream added on 2014-06-13T19:20:10Z : No. of bitstreams: 1 faro_am_dr_jabo.pdf: 822597 bytes, checksum: 4ff373e7766ea6fc979fd196b294ed7f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O emprego de membranas biológicas em cirurgias reparadoras tem sido amplamente estudado nos últimos anos sob inúmeros aspectos, principalmente no que se refere à adequação entre o tipo de implante e sua atividade no leito receptor. O estudo desenvolvido teve como escopo o desenvolvimento e avaliação de técnica para restauração da parede torácica de cães com utilização de cartilagem auricular suína tratada pela glicerina. Para tanto, utilizou-se nove cães adultos, hígidos, que foram avaliados histopatológica, radiográfica e clinicamente, cujos resultados incluíram facilidades na obtenção, preservação e utilização desta bioprótese, baixa reação inflamatória propiciada pelo leito receptor, ausência de movimento paradoxal da parede torácica pós-implantação, além de integração com o tecido adjacente notada aos 60 dias. Concluiu-se, a partir desta avaliação experimental, que a integridade do implante foi nitidamente notada em todos os momentos de avaliação; a técnica é relativamente simples, de rápida evolução clínica, e de baixo custo; a cartilagem auricular suína em meio de preservação é um excelente material para reparação da parede torácica sob as condições estudadas. / The usage of biological prosthesis in surgical repair procedures has been widely studied in the last years, mainly in what concerns application of the adequate implant type and its activity in the receptor site besides to its chemical, physical, pathological and immunological characteristics. The present study had as purpose to evaluate a surgical technique, the restoration of dog’s thoracic wall applying preserved swine auricular cartilage bioprosthesis, by describing the surgical technique, clinical, histological and radiographic founds. So, 9 dogs, clinically healthy, were evaluated by histopathologic, radiographic and clinical aspects. Such evaluation shown as results, the easiness for implant acquisition, preservation and use, besides to the low reaction by the receptor site, thoracic wall paradoxal movement absent after implantation, and biological implant-adjacent tissues integration after 60 days. Through this experimental evaluation, the found conclusions were: the implant integrity was clearly noted in all evaluation moments; the technique is relatively simple, with fast clinical evolution, and low cost; the preserved swine auricular cartilage is a great material do repair de thoracic wall under the studied conditions.
10

Análise semiquantitativa da reação inflammatória e quantitativa da deposição colágena de telas de polipropileno monofilamentar recobertas com matriz polimérica eluidora de S-nitrosoglutationa implantadas no subcutãneo de ratas adultas / Semi quantitative analysis of inflammatory reaction and quantitative collagen deposition evaluation of monofilament polypropylene mesh coated with S-nitrosoglutathione-releasing poly (vinyl alcohol) film implanted in subcutneous o female rats

Santos, Alessandro Corrêa Prudente dos, 1978- 16 August 2018 (has links)
Orientadores: Cássio Luís Zanettini Riccetto, Marcelo Ganzarolli de Oliveira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-16T02:05:33Z (GMT). No. of bitstreams: 1 Santos_AlessandroCorreaPrudentedos_M.pdf: 2396933 bytes, checksum: 15e0ba5362fd0f6648c8ca4f6aea3f8c (MD5) Previous issue date: 2010 / Resumo: Introdução: A introdução de telas de polipropileno no reparo de incontinência urinária e distopias genitais diminuiu a recorrência do problema, mas também trouxe o inconveniente de complicações como extrusões vaginais. O óxido nítrico (NO) tem propriedades vasodilatadoras e moduladoras dos processos inflamatórios. Assim, o recobrimento das telas com matriz polimérica eluidora de um carreador de NO pode modificar a resposta tecidual ao implante em organismos biológicos. Objetivo: Estudar o efeito do recobrimento com matriz polimérica eluidora do carreador de NO, S-nitrosoglutationa (GSNO), na resposta biológica tecidual de telas de polipropileno (PP) monofilamentar implantadas no subcutâneo de ratas adultas. Materiais e Métodos: Utilizaram-se 20 ratas fêmeas da raça Wistar (peso médio= 250 g). Cada animal recebeu o implante de 4 fragmentos de tela medindo 10 x 10 mm no subcutâneo. As amostras obtidas dos animais foram divididas em 7 grupos, designados como: grupo PP - tela de PP sem recobrimento (grupo controle) (n=20); grupo PVA -tela de PP com recobrimento de poli(alcool vinílico) (n=10); grupo PVA/PVP - tela de PP com recobrimento de blenda de poli(alcool vinílico)/poli(vinil pirrolidona) (n=10); grupo PVA/GSNO 1 - tela de PP com recobrimento de poli(alcool vinílico), contendo GSNO 1 mM (n=10); grupo PVA/GSNO 10 - tela de PP com recobrimento de poli(alcool vinílico) contendo GSNO 10mM (n= 10), grupo PVA/PVP/GSNO 1 - tela de PP com recobrimento de poli(álcool vinílico)/poli(vinil pirrolodona), contendo GSNO 1mM (n=10); grupo PVA/PVP/GSNO 10 - tela de PP com recobrimento de poli(alcool vinílico)/poli(vinil pirrolodona) contendo GSNO 10mM (n= 10). Dez ratas foram eutanasiadas após 2 dias e outras dez após 21 dias do procedimento cirúrgico. Após a eutanásia, uma excisão em bloco da parede abdominal foi feita para análises microscópicas. Infiltrado inflamatório, edema e angiogênese foram avaliados em lâminas coradas com Hematoxilina-Eosina (HE). A deposição colágena foi avaliada em lâminas coradas com Picrosirius Red. As variáveis estudadas nas lâminas HE foram categorizadas em ausente, leve, moderado ou intenso. A formação colágena foi quantificada com método estereológico. Todas as avaliações foram feitas pelo mesmo pesquisador, que não sabia de que animal ou fragmento se tratava a lâmina que estava analisando. Resultados: Nas ratas eutanasiadas após dois dias do procedimento, não se identificou diferença estatística entre os diversos tratamentos. No entanto, naquelas estudadas após 21 dias do implante, observou-se menor edema (p=0.0039) tecidual e maior angiogênese (p=0.0031) no grupo PVA/GSNO 1. O grupo PVA também demonstrou maior formação vascular que o controle (p=0.0027). Além disso, ratas eutanasiadas aos 21 dias apresentaram maior infiltrado inflamatório (p= 0,0474) e menor edema (p=0,0064) quando comparadas àquelas aos 2 dias. Na quantificação de fibras colágenas, não houve diferença significativa entre os fragmentos. Conclusões: O recobrimento com PVA e PVA contendo GSNO modificou a resposta biológica tecidual de telas de PP monofilamentar implantadas no subcutâneo de ratas adultas. O recobrimento com PVA, isoladamente ou contendo GSNO 1mM demonstrou efeito angiogênico. O grupo PVA/GSNO 1 apresentou, ainda, redução do edema. Não houve diferenças significativas da deposição colágena / Abstract: Introduction: The use of polypropylene (PP) mesh to repair urinary incontinence and vaginal prolapse has decreased recurrence. However, it has also been related to specific complications such as vaginal erosions. Nitric oxide (NO) can produce vasodilatation and modulate inflammatory reaction. The NO containing (S-nitrosoglutathione - GSNO) eluted from a polymeric coating could modify tissue response of meshes. Objective: To study the effect of a NO containing (S-nitrosoglutathione - GSNO) eluted from a polymeric coating in the tissue response of monofilament polypropylene mesh implanted in subcutaneous of rats. Materials and Methods: Twenty adult female Wistar rats were used (mean weight: 250g). Four mesh fragments measuring 10 x 10 mm were implanted in subcutaneous tissue of each rat. The samples were divided in 7 groups: PP group - PP mesh without coating (control) (n=20); PVA group - PP mesh coated with poly(vinyl alcohol) (PVA) (n=10); PVA/PVP group - PP mesh coated with a solution of poly(vinyl alcohol) and poly(vinyl pyrrolidone) (PVA/PVP) (n=10); PVA/GSNO 1 group - PP mesh coated with PVA containing GSNO 1mM (n=10); PVA/GSNO 10 group - PP mesh coated with PVA containing GSNO 10mM (n=10); PVA/PVP/GSNO 1 group - PP mesh coated with PVA/PVP containing GSNO 1mM (n=10); PVA/PVP/GSNO 10 group - PP mesh coated with PVA/PVP containing GSNO 10mM (n=10);. Ten rats were euthanized at 2 days and the other at 21 days postoperatively. Abdominal wall was excised en bloc for microscopic analyses. Inflammatory infiltrate, edema and angiogenesis were analyzed in hematoxilin-eosin (HE) slices and categorized as absent, mild, moderate or severe. The collagen deposition was stained with Picrosirius red and quantified using stereological method. The same researcher did all evaluations without knowing what fragment he was analyzing. Results: No statistical difference was identified among treatments in euthanized rats at two days after the implants. However, in rats studied at 21 days, less edema (p=0.0039) and greater angiogenesis (p=0.0031) were observed for PVA/GSNO 1 group. PVA group also was related to induced a higher angiogenesis (p=0.0027). Furthermore, euthanized rats at 21 days demonstrated a greater inflammatory infiltrate (p= 0,0474) and less edema (p= 0,0064) than those at two days. In collagen deposition analyses no statistical difference was identified among treatments. Conclusion: Coating monofilament PP meshes with GSNO-containing PVA modified the tissue response when implanted in subcutaneous of rats. The PVA alone or with GSNO 1 showed angiogenic effect. The PVA/GSNO1 group presented less edema too. There were not effects in collagen deposition / Mestrado / Cirurgia / Mestre em Cirurgia

Page generated in 0.0388 seconds