• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 814
  • 25
  • 24
  • 24
  • 23
  • 15
  • 14
  • 14
  • 8
  • 7
  • 7
  • 6
  • 2
  • 2
  • 1
  • Tagged with
  • 848
  • 320
  • 276
  • 251
  • 215
  • 202
  • 194
  • 192
  • 189
  • 181
  • 170
  • 164
  • 157
  • 123
  • 107
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Influência do laser de Nd:Yag na resistência de união de Materiais resinosos à dentina. Efeito do laser de Nd : Yag e de Er:Yag na interface adesivodentina : estudo em MEV

Ghiggi, Paula Cristine January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:09Z (GMT). No. of bitstreams: 2 000409045-0.pdf: 2621932 bytes, checksum: 3dd68f9c8fb1c8ea3799e2e33658b7c3 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study evaluated the bond strength of different adhesive materials on dentin with Nd:YAG laser. Eighteen third human molars, extracted due to therapeutic recommendation, had their roots included in self-cured acrylic resin. Occlusal enamel was removed using a diamond saw and the dentin surface was exposed, followed by surface regularization with 400 and 600 grit silicon carbide sandpaper under water cooling. Teeth were randomly divided in 6 groups: Group 1 – adhesive system Adper Single Bond 2; Group 2 – adhesive system Clearfil SE Bound; Group 3 – self-adhesive resin luting cement Rely X Unicem; Group 4 – irradiation with Nd:YAG laser and application of Adper Single Bond 2; Group 5 – irradiation with Nd:YAG laser and application of Clearfil SE Bond; Group 6 – irradiation with Nd:YAG laser and application of Rely X Unicem. Nd:YAG was applied in the following parameters: 60 mJ, 15 Hz, 0. 9 W, 47,77 J/cm2, 100 μs. Composite resin blocks with 6 mm height were built upon the adhesive materials. Tooth/resin sets were stored in distilled water at 37º C for 24 hours and then cut with a diamond saw using a laboratory cutting machine to obtain the beams samples. Twenty samples were selected in each group, and submitted to microtensile bond strength on a universal testing machine EMIC DL – 2000 at crosshead speed of 0,5mm/min. Results were evaluated according to Variance Analysis and Tukey test ( =0,05). The highest bond strength mean was obtained with Clearfil SE Bond (41. 75 MPa) without laser application. However, when the laser was applied, the bond strength value decreased (33. 42 MPa), but without statistically significant differences. The bond strength of Adper Single Bond without laser application (32. 15 MPa) did not differ statistically from Group 4 (35. 38 MPa). Self-adhesive resin luting cement Rely X Unicem obtained the lowest bond strength, being the value with laser application (7. 53 MPa) statistically lower than the value without laser application (14. 50 MPa). It was concluded that Nd:YAG laser did not decrease significantly the bond strength of the adhesive systems studied, only for the self-adhesive resin luting cement. / Este estudo avaliou a resistência de união de diferentes materiais adesivos à dentina irradiada com laser de Nd:YAG. Dezoito terceiros molares humanos, extraídos por indicação terapêutica, tiveram as raízes embutidas em resina acrílica quimicamente ativada. A dentina oclusal foi exposta pela remoção do esmalte com disco diamantado, seguido de acabamento com lixas de carbeto de silício 400 e 600 sob refrigeração. Os dentes foram divididos aleatoriamente em seis grupos: G1: sistema adesivo Adper Single Bond 2; G2: sistema adesivo Clearfil SE Bond; G3: cimento resinoso auto-adesivo Rely X Unicem; G4: irradiação com o laser de Nd:YAG e aplicação do sistema adesivo Adper Single Bond 2; G5: irradiação com o laser de Nd:YAG e aplicação do sistema adesivo Clearfil SE Bond; G6: irradiação com o laser de Nd:YAG e aplicação do cimento resinoso auto-adesivo Rely X Unicem. O laser foi aplicado nos parâmetros de 60 mJ, 15 Hz, 0,9 W, 47,70 J/cm2, duração do pulso 100 μs. Um bloco de resina composta, com aproximadamente 6 mm de altura, foi construído, de forma incremental, sobre os materiais adesivos. Os conjuntos dente/restauração foram armazenados em água destilada por 24 horas a 37oC, e então seccionados com disco diamantado em cortadeira de precisão para obtenção de corpos-de-prova na forma de palitos. Vinte corpos-de-prova foram selecionados para cada grupo, sendo submetidos ao teste de microtração em máquina de ensaio universal EMIC DL-2000 com velocidade de 0,5 mm/minuto. Os resultados foram submetidos à Análise de Variância e teste de Tukey ( =0,05). O maior valor médio de resistência de união foi obtido para o Clearfil SE Bond (41,75 MPa) sem aplicação do laser. No entanto, quando o laser foi aplicado, houve uma redução no valor de resistência de união (33,42 MPa), porém sem diferença estatisticamente significante. A resistência de união do Adper Single Bond 2 sem laser (32,15 MPa) também não diferiu estatisticamente com a aplicação do laser (35,38 MPa). O cimento resinoso Rely X Unicem proporcionou os menores valores de resistência de união, sendo o valor da resistência de união com aplicação do laser (7,53 MPa) estatisticamente inferior quando o mesmo não foi aplicado (14,50 MPa). Concluiu-se que o laser de Nd:YAG não influenciou significativamente a resistência de união dos sistemas adesivos, mas apenas para o grupo do cimento resinoso auto-adesivo.
152

Avaliação da aplicação de uma solução ácida experimental na resistência de união de sistemas adesivos

Melara, Rafael January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:28Z (GMT). No. of bitstreams: 2 000430098-0.pdf: 130972 bytes, checksum: 7163cf89fa076e570e8462a27723ebe0 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study aimed to evaluate, in vitro, the bond strength of adhesive systems Adper Scotchbond SE (3M/ESPE) and Adper Scotchbond Multi-Purpose (3M/ESPE) to dentin treated or not with an experimental acid solution. The occlusal surface of twenty sound human molars was removed to obtain a flat dentin area. The teeth were divided into four groups according to the type of adhesive system used and whether the experimental solution was used or not. In groups Adper Scotchbond SE Control and Scotchbond Multi-Purpose Control, the adhesive system was applied according to the manufacturer's instructions. In group Adper Scotchbond SE Experimental, an experimental solution was applied previously to the adhesive system, and in group Adper Scotchbond Multi¬Purpose Experimental, the phosphoric acid 37% was replaced by the application of experimental solution. After applying the adhesive system, a block of composite resin (Z350 - 3M/ESPE), with approximately 6 mm in height was made. After, the teeth were stored in distilled water for 24 h in a culture oven at 37°C. Thereafter, the teeth were sectioned in the direction "x" and "y" to obtain sticks with adhesive area of approximately 1. 0 mm2. Sixteen sticks by group were tested in a microtensile testing machine (EMIC DL-2000) at a speed of 0. 5 mm/min. After the microtensile test, the sticks were evaluated by SEM, to establish the predominant pattern of failure by fractography. According to the analysis of variance two-way there was no statistically significant difference in bond strength values among the four groups. The predominant type of failure observed in SEM was cohesive in the adhesive, followed by cohesive in the hybrid layer. SEM analysis showed that the experimental solution was able to remove the smear layer exposing dentin tubules. Based on these results we conclude that the use of experimental solution in combination with the adhesive systems was able to promote values of bond strength similar to the technique of application as recommended by the manufacturers, and this experimental acid solution was able to obtain a conditioning of dentin surface similar to that obtained with 37% phosphoric acid. / Este estudo teve por objetivo avaliar, in vitro, a resistência de união dos sistemas adesivos Adper Scotchbond SE (3M/ESPE) e Adper Scotchbond Multi-Uso (3M/ESPE) à superfície dentinária tratada ou não com uma solução ácida experimental. A superfície oclusal de vinte terceiros molares humanos hígidos foi removida para a obtenção de uma área plana de dentina. Os dentes foram divididos em 4 grupos, de acordo com o tipo de sistema adesivo usado e aplicação ou não da solução experimental. Nos grupos Adper Scotchbond SE Controle e Adper Scotchbond Multi-Uso Controle, o sistema adesivo foi aplicado de acordo com as instruções do fabricante. No grupo Adper Scotchbond SE Experimental foi aplicada a solução experimental previamente ao sistema adesivo, e no grupo Adper Scotchbond Multi-Uso Experimental, o condicionamento com ácido fosfórico a 37% foi substituído pela aplicação da solução experimental. Após a aplicação do sistema adesivo, um bloco de resina composta (Z350 - 3M/ESPE), com aproximadamente 6 mm de altura, foi confeccionado, sendo os dentes armazenados em água destilada por 24 h em uma estufa de cultura a 37°C. Decorrido este período, os dentes foram seccionados nos sentido “x” e “y” a fim de obter palitos com área adesiva de aproximadamente 1,0 mm2. Dezesseis palitos por grupo foram submetidos ao teste de microtração em uma máquina de ensaios (EMIC DL-2000), a uma velocidade de 0,5 mm/min. Após o teste de microtração, os palitos foram avaliados em microscopia eletrônica de varredura, para estabelecimento do padrão predominante de falha, por meio de fractografia. De acordo com a análise de variância segundo duas vias não houve diferença estatisticamente significativa nos valores de resistência de união entre os quatro grupos, para os fatores adesivos e tratamentos de superfície. O tipo de falha predominante observado em MEV foi coesiva em adesivo, seguido de coesiva em camada híbrida.A análise em MEV mostrou que a solução experimental foi capaz de remover a smear layer expondo túbulos dentinários. Com base nos resultados encontrados é possível concluir que o uso da solução experimental contendo um inibidor de metaloproteinases, em associação aos sistemas adesivos estudados, foi capaz de promover valores de resistência de união 3 semelhantes à técnica de aplicação recomendada pelos fabricantes; e que essa solução ácida experimental foi capaz de obter um padrão de condicionamento de superfície dentinária semelhante ao obtido com o ácido fosfórico a 37%.
153

Eficácia de dois métodos de clareamento dental e sua influência sobre as propriedades físico-químicas e sobre a resistência à união de sistemas adesivos

Marcondes, Maurem January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:29Z (GMT). No. of bitstreams: 2 000387564-0.pdf: 2940203 bytes, checksum: cf1530adcd62580b3d499dcac450127c (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / In order to fulfill the growing demand for bleaching treatments at dental clinics, several researches about different dental whitening techniques have been carried out, using bleaching agents with different concentrations and formulas. The aim of this study was to evaluate in vitro: a) the color change of human teeth bleached with 35% hydrogen peroxide associate to pigment with different wavelengths and irradiated with Nd:YAG laser or halogen curing light; b) the Vickers hardness number (VHN) of these specimens, before and after the whitening treatments; c) the enamel’s surface topography through MEV; d) the tensile strength of two adhesive systems containing acetone or ethanol; e) the fracture pattern after mechanical test of tensile bond strength using MEV. Seventy five extracted human molars had the crown split at the mesio-distal sense and the 150 fragments obtained were divided into five groups according to the bleaching agent and photo activation type: WL (Whiteness HP Maxx and Nd:YAG laser), WH (Whiteness HP Maxx and halogen light), QL (H2O2+carbopol+Q-Switch and Nd:YAG laser), QH (H2O2+carbopol+Q-Switch and halogen light) e C (Control, without bleaching treatment).The shade guide Vita color evaluation and the Vickers hardness number test were realized before and after the bleaching treatments. After two weeks of storage in artificial saliva, the groups were subdivided in order to carry out the restorative treatments, using the adhesive systems Adper Single Bond 2 and Solobond M. Right after, the tensile strength test and the analysis of the fracture pattern were made. The color varied seven tabs on the groups irradiated with the Nd:YAG laser and eight tabs on the groups irradiated with the halogen light. According to the t-student test, there were no significant difference to the VHN before or after the clearing treatments (p>0. 05). According to ANOVA, the tensile strength values did not indicate statistic difference between the tested groups and its controls, regarding the two types of adhesive tested (p>0. 05), being the mixed fail, the most frequent fracture pattern. The superficial morphology of the bleached enamel presented alteration on topography and these characteristics were not significant on tensile bond strength. In conclusion all protocols were efficient for bleaching the specimens and to the restorative procedure with composite resin after the treatment. / A fim de atender a crescente demanda por clareamento nos consultórios odontológicos, pesquisas acerca de diferentes técnicas, concentrações e fórmulas de agentes clareadores estão sendo realizadas. O objetivo desse estudo foi avaliar in vitro: A) a alteração de cor de dentes humanos clareados com peróxido de hidrogênio 35% associado à corantes com diferentes comprimentos de onda e irradiados com laser de Nd:YAG ou luz halógena; B) a microdureza Vickers (VHN) destes espécimes antes e após os tratamentos clareadores; C) topografia da superfície do esmalte pela MEV; D) a resistência de união à tração de dois sistemas adesivos, um contendo acetona e o outro etanol; E) o padrão de fratura dos corposde- prova com auxílio da MEV após o ensaio de resistência de união à tração. Setenta e cinco molares humanos extraídos tiveram a coroa seccionada no sentido mésio-distal e os 150 fragmentos obtidos foram divididos em cinco grupos conforme o agente clareador e tipo de fotoativação: WL (Whiteness HP Maxx e Laser de Nd:YAG), WH (Whiteness HP Maxx e luz Halógena), QL (H2O2+carbopol+Q-Switch e laser de Nd:YAG), QH (H2O2+carbopol+QSwitch e luz Halógena) e C (Controle, sem clareamento).A avaliação de cor pela escala Vita e o teste de microdureza Vickers foram realizados antes e depois dos tratamentos clareadores. Após duas semanas de armazenamento em saliva artificial, os grupos foram subdivididos para a realização dos tratamentos restauradores com os sistemas adesivos Adper Single Bond 2 e Solobond M e, logo após, realizado o ensaio de resistência à tração e análise do padrão de fratura. A cor variou sete níveis para os grupos irradiados pelo laser de Nd:YAG e oito níveis para os grupos irradiados pela luz halógena. De acordo com o teste t-student, não houve diferença significativa para a VHN antes e depois dos clareamentos (p>0,05). Segundo ANOVA, os valores de resistência de união não indicaram diferença estatística entre os grupos teste e seus controles para os dois tipos de adesivos testados (p>0,05), sendo o padrão de fratura mais freqüente o de falha mista. Houve alterações na superfície do esmalte, todavia, não foram significativas a ponto de modificar a resistência de união dos sistemas adesivos. Concluí-se que todos os protocolos realizados nesta pesquisa foram eficazes para o clareamento dos espécimes, bem como para o procedimento restaurador após o tratamento.
154

Tratamentos de superfície para aumentar a resistência de união adesiva à zircônia

Paranhos, Maria Paula Gandolfi January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:30Z (GMT). No. of bitstreams: 2 000427526-0.pdf: 20667486 bytes, checksum: 1d99d8d1b05458aa30749d927735a2df (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Foram realizados dois estudos in vitro para avaliar resistência de união de cimentos resinosos à zircônia após diferentes tratamentos de superfície e um estudo in vitro para avaliar a resistência à fadiga de coroas não-retentivas cimentadas adesivamente em pilares de zircônia conforme protocolo adesivo definido pelos estudos de resistência de união.
155

Análise da resistência de união à dentina humana submetida ao condicionamento total sob pressão pulpar simulada e armazenamento em etanol 75%

Holleben, Priscila [UNESP] 05 February 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-02-05Bitstream added on 2014-06-13T18:40:25Z : No. of bitstreams: 1 000758137.pdf: 2416656 bytes, checksum: 89bb5e8254e1666f93f5d7e8ebf6d77e (MD5) / A degradação hidrolítica da interface adesiva é o fator mais crítico na longevidade dos procedimentos restauradores. O objetivo deste estudo, in vitro, foi avaliar, por meio do teste de microtração, a resistência de união do sistema adesivo Scotchbond Universal (SU, 3M ESPE) à dentina humana, submetida à simulação da pressão pulpar e ao armazenamento em água deionizada ou etanol 75% por 1 dia, 10 dias e 30 dias. O sistema adesivo foi aplicado de acordo com a técnica do condicionamento total e sob a simulação de 0 ou 15 cm de H2O de pressão pulpar (durante todo o procedimento restaurador). Foram utilizados 60 terceiros molares humanos divididos em 4 grupos: G1) SU aplicado sem simulação da pressão pulpar (0 cm H2O) e armazenado em água deionizada; G2) SU aplicado sem simulação da pressão pulpar (0 cm H2O) e armazenado em etanol 75%; G3) SU aplicado com simulação da pressão pulpar (15 cm H2O) e armazenado em água deionizada; G4) SU aplicado com simulação da pressão pulpar (15 cm H2O) e armazenado em etanol 75%. Os espécimes foram restaurados com a resina composta Filtek Z350 XT (3M ESPE). Após 48 h em água deionizada a 37ºC, os espécimes foram seccionados para a obtenção de palitos com área adesiva de aproximadamente 1 mm2, que foram submetidos ao teste de microtração após mais 1 dia, 10 dias ou 30 dias de armazenamento em água deionizada ou etanol 75%. A variação da resistência de união foi analisada pelos testes estatísticos ANOVA 3-fatores e Tukey (5% de significância). Todas as variáveis experimentais – pressão pulpar (p=0,0007), meio de armazenamento (p=0,0006) e tempo (p=0,0033) – tiveram influência estatisticamente significante sobre a resistência adesiva (p<0,05). O grupo restaurado sem pressão pulpar e armazenado em água por 1 dia apresentou a maior média (35,26  4,63 A), que diferiu estatisticamente dos grupos restaurado... / The hydrolytic degradation of adhesive interface is the most critical factor affecting the longevity of restorative procedures. The aim of this in vitro study was to evaluate the microtensile bond strength of Scotchbond Universal Adhesive (SU, 3M ESPE) to human dentin, submitted to simulated pulpal pressure and stored in either deionized water or 75% ethanol for 1 day, 10 days and 30 days. The adhesive system was applied according to the total-etch technique and under the simulation of either 0 or 15 cm of H2O pressure (during all the restorative procedure). Sixty human third molars were used and divided into 4 groups: G1) SU applied without pulpal pressure (0 cm H2O) and stored into deionized water; G2) SU applied without pulpal pressure (0 cm H2O) and stored into 75% ethanol; G3) SU applied with pulpal pressure (15 cm H2O) and stored into deionized water; G4) SU applied with pulpal pressure (15 cm H2O) and stored into 75% ethanol. The specimens were restored with Filtek Z350 XT composite resin (3M ESPE). After 48 h in deionized water at 37ºC, the specimens were sectioned into dentin-resin beams with 1 mm2 of bonding area, which were submitted to the microtensile bond strength test after 1 day, 10 days or 30 days of storage in either deionized water or 75% ethanol. The variation of bond strength was determined by using 3-way ANOVA and Tukey’s test (5% level of significance) analyses. All experimental variables – pulpal pressure (p=0.0007), storage media (p=0.0006) and time (p=0.0033) – had a statistically significant influence on the bond strength (p<0.05). The group restored without pulpal pressure and stored in water for 1 day showed the highest mean (35.26  4.63 A). This group was significantly different from groups restored with pulpal pressure and stored in water for 30 days (25.21  4.80 B) and ethanol for 10 days (24.63  3.18 B) and 30 days (23.31  6.25 B). Therefore, the ....
156

Avaliação da citotoxicidade transdentinária dos sistemas adesivos universais

Santos, Andressa Fabro Luciano dos 21 August 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2014. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-11-25T16:31:14Z No. of bitstreams: 1 2014_AndressaFabioLucianodosSantos.pdf: 2463096 bytes, checksum: 0f94b500d050b15c1c40a228929105d3 (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2014-11-26T11:09:56Z (GMT) No. of bitstreams: 1 2014_AndressaFabioLucianodosSantos.pdf: 2463096 bytes, checksum: 0f94b500d050b15c1c40a228929105d3 (MD5) / Made available in DSpace on 2014-11-26T11:09:56Z (GMT). No. of bitstreams: 1 2014_AndressaFabioLucianodosSantos.pdf: 2463096 bytes, checksum: 0f94b500d050b15c1c40a228929105d3 (MD5) / O objetivo deste estudo foi avaliar a citotoxicidade transdentinária de sistemas adesivos universais sobre cultura primária de células pulpares. Setenta discos de dentina foram obtidos de dentes terceiros molares humanos íntegros e divididos em sete grupos considerando sua condutância hidráulica. Os discos foram montados em câmaras pulpares artificiais e sob sua superfície pulpar, foram cultivadas células por 48 horas. Os grupos foram definidos da seguinte forma: G1 - controle (PBS), G2 - convencional de 3 passos (Adper™ Scotchbond™ Multi-purpose); G3 - autocondicionante de passo único (Clearfil™ SE3 Bond); G4 e G5 - autocondicionante de passo único e convencional de 2 passos, respectivamente (Scothbond™ Universal); G6 e G7 - autocondicionante e convencional de 2 passos, respectivamente (Peak® Universal Bond). Decorridos 24 horas, foram avaliados o metabolismo celular pelo teste do MTT e a morfologia pela MEV. O meio de cultura em contato com as células foi coletado e utilizado para análise de morte celular utilizando o sistema de imagem celular GE InCell Analyzer 2000. Os dados foram avaliados pelos testes não-paramétricos de Kruskal-Wallis seguido do teste comparativo de Mann-Whitney (p<0,05). Todos os sistemas adesivos testados reduziram a porcentagem do metabolismo celular, comparados com o grupo controle. Os mais citotóxicos foram os grupos G5 e G2. Os grupos G2, G3, G4, G5, G6 e G7 reduziram o metabolismo em 33,7%, 19,2%, 16,83%, 42,27%, 28,83% e 8,86%, respectivamente. O potencial citotóxico dos adesivos foi G5 > G2 > G6 > G3 > G4 > G7. O G6 produziu o efeito mais fraco de indução de morte por apoptose nas células da polpa, por outro lado, os grupos G2 e G7 resultaram nos maiores valores (16,58% e 15,03%), respectivamente. A maior porcentagem de necrose foi induzida pelo grupo G2 (63,44%), sendo esta estatisticamente diferente de todos os grupos, exceto para o G4. Morte celular por necrose foi o tipo mais prevalente induzida pelos adesivos estudados. Todos os sistemas adesivos testados causaram morte (apoptose e necrose), lesão celular e alterações de morfologia, o que indica potencial citotóxico para as células pulpares. ______________________________________________________________________________ ABSTRACT / The aim of this study was to evaluate the transdentinal cytotoxicity of universal adhesive systems using pulp cells culture. Seventy dentin disks were obtained from intact human third molars and divided into seven groups considering their hydraulic conductance. The disks were adapted on artificial pulp chamber and cells were seeded over their pulpal surface. After 48 hours, the chambers were inverted and the adhesive procedures were performed according to the groups: G1 - control (PBS), G2 – etch-and-rinse 3 step (Adper ™ Scotchbond ™ Multi-purpose); G3 – self-etch single step (Clearfil ™ SE3 Bond); G4 and G5 – etch-and-rinse single step and self-etch 2 steps, respectively (Scothbond ™ Universal); G6 and G7 – etch-and-rinse and self-etch 2 steps, respectively (Peak Universal Bond ®). After 24 hours, cell metabolism was evaluated by MTT assay and morphology by SEM. The culture medium in contact with the cells was collected and used to analyze death cell using the system image GE Incell Cell Analyzer 2000. Data were analyzed by non-parametric Kruskal-Wallis test followed by comparison Mann-Whitney (p <0.05). All adhesive systems reduced the percentage of cell metabolism compared with the control group. The lowest value of SDH production was observed for G5, followed by G2. The reduction of cell metabolism were of 33.7%, 19.2%, 16.83%, 42.27%, 28.83% and 8.86% for G2, G3, G4, G5, G6 and G7, respectively. The cytotoxic potential of the adhesive systems were G5> G2> G6> G3> G4> G7. G6 produced the weakest effect of inducing cell death by apoptosis. On the other hand, G2 and G7 groups produced the highest values (16.58% and 15.03%), respectively. The highest percentage of necrosis was induced by G2 (63.44%), statistically different from all groups, except from the G4. Necrotic cell death was the most prevalent type of cell death for all adhesives tested. All adhesive systems caused cell death (apoptosis and necrosis), reduction of cellular metabolism and alterations on cell morphology, indicating their cytotoxic potential for pulp cells.
157

Avaliação da resistência de união de sistemas adesivos à dentina saturada com água ou etanol

Guimarães, Leandro Afonso 18 December 2009 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2009. / Submitted by Shayane Marques Zica (marquacizh@uol.com.br) on 2011-06-28T17:41:43Z No. of bitstreams: 1 2009_LeandroAfonsoGuimaraes.pdf: 833040 bytes, checksum: 75f5cf8223c6e84f037d0f03daf98c72 (MD5) / Approved for entry into archive by Guilherme Lourenço Machado(gui.admin@gmail.com) on 2011-06-29T15:22:05Z (GMT) No. of bitstreams: 1 2009_LeandroAfonsoGuimaraes.pdf: 833040 bytes, checksum: 75f5cf8223c6e84f037d0f03daf98c72 (MD5) / Made available in DSpace on 2011-06-29T15:22:05Z (GMT). No. of bitstreams: 1 2009_LeandroAfonsoGuimaraes.pdf: 833040 bytes, checksum: 75f5cf8223c6e84f037d0f03daf98c72 (MD5) / O objetivo geral deste estudo foi o de avaliar a resistência de união (RU) de sistemas adesivos que empregam condicionamento ácido total à dentina, utilizando-se a técnica úmida com água ou a técnica úmida com etanol. A superfície oclusal de vinte terceiros molares extraídos foi preparada removendo-se o esmalte oclusal junto a superfície esmalte-dentina. A superfície dentinária foi exposta e condicionada com ácido fosfórico a 37% por 15 sec, seguida de lavagem abundante e secagem com papel absorvente. A superfície foi mantida úmida (técnica úmida com água) ou saturada com etanol a 100% por 30 seg. (técnica úmida com etanol). Em seguida foram aplicados os sistemas adesivos de acordo: grupo 1: Adper Single Bond 2-SB (técnica úmida com água); grupo 2: Adper Single Bond 2-SB (técnica úmida com etanol); grupo 3: Scotchbond Multipurpose Plus-SBMP ( técnica úmida com água) e grupo 4: Scotcbond Multipurpose Plus-SBMP (técnica úmida com etanol) seguindo a recomendação do fabricante. Foi construída uma coroa de resina composta pela técnica incremental. Após 24 horas de armazenamento em água destilada em estufa (37°C), os espécimes foram preparados para o teste de microtração. Os dados obtidos da RU foram submetidos à análise de variância (ANOVA) a dois critérios (Adesivo x Técnica), seguido do teste de Tukey (p< 0,05). Não houve interação entre adesivo e técnica empregada ( p=0,597).O sistema adesivo SB apresentou maior valor de RU em ambas as técnicas empregadas,úmida com água ou úmida com etanol, comparado ao SBMP (p<0,05). Os resultados não mostraram diferenças estatísticas significantes entre as técnicas para ambos os sistemas adesivos empregados (p>0,05). Estudos adicionais empregando a técnica úmida com etanol , avaliando a longevidade ,utilizando sistemas adesivos comerciais são necessários. _______________________________________________________________________________ ABSTRACT / This study examined the immediate resin-dentin bond strength of etch-and-rinse adhesives bonded to acid-etched dentin saturated with water or ethanol. The occlusal one-third of the crown was removed from twenty unerupted human third molars; a uniform smear layer was created with 600 grit SiC. The dentin surface was acid-etched, left moist and saturated with water (water wet-bonding) or ethanol (ethanol wet-bonding). The total-etch adhesives used were: group 1: Adper Single Bond-SB (water wet-bonding) ; group 2: Adper Single Bond-SB (ethanol wet-bonding); group 3: Adper Scothbond Multipurpose-SBMP (water wet-bonding) or group 4: Adper Scothbond Multipurpose-SBMP (ethanol wet-bonding).These adhesives were then applied to both water-and-ethanol saturated dentin according manufacturer’s direction. Resin composite buildups were constructed incrementally. After storage in water for 24h at 370, the specimens were prepared for microtensile bond strength (μTBS) testing. Data were analyzed by two-way ANOVA and Tukey Multiple comparison test (p<0.05). There was not a statistically significant interaction between adhesive and technique (p = 0.597). The highest bond strength values were observed to SB for both water and ethanol-wet-bonding technique (p<0.05). For both adhesives there was not difference in bond strength values for water and ethanol-wet bonding (p>0.05). The adhesive SB performed better for overall conditions tested compared to SBMP. The ethanol-wet bonding promoted similar immediate bond strengths compared to water-bonding for both adhesives. Further investigations are needed using ethanol-wet bonding to test a long- term bond strengths.
158

Estudo 'In Vitro' da Infiltração Marginal em Dentes Submetidos a Diferentes Técnicas de Clareamento e Restaurados com um Sistema Adesivo/Resina Composta.

Patrícia de Almeida Rodrigues da Silva e Souza 05 August 1999 (has links)
Foi avaliado o efeito do clareamento na infiltração marginal de dentes restaurados com o sistema adesivo Scotchbond Multi-uso Plus e resina composta Z-100. Sessenta pré-molares foram divididos em 6 grupos: grupo I, técnica imediata, uma bolinha de algodão saturada em peróxido de hidrogênio a 30% foi colocada no interior da câmara coronária e na superfície vestibular dos dentes e aquecida a uma temperatura de 42ºC por 3 períodos de 15 minutos, num total de três sessões semanais; grupo II, técnica mediata, era selado um curativo na câmara coronária de peróxido de hidrogênio a 30% mais perborato de sódio por 21 dias, e no intervalo de sete dias renovado; grupo III, associação das duas técnicas acima descritas; grupo IV, técnica caseira com aplicação de peróxido de carbamida a 10% por três horas diárias durante 21 dias; grupo V, associação da técnica caseira mais mediata; grupo VI foi o controle que não foi submetido ao tratamento clareador. Após, todos os grupos permaneceram com um curativo de hidróxido de cálcio por dez dias, para em seguida serem restaurados, termociclados e imersos em fucsina básica à 0,5% por 24 horas. A medida da penetração do corante pela interface dente restauração foi realizada através do programa ImageTool. As médias obtidas foram de 3,09; 1,83; 2,11; 2,36; 1,60 e 2,20(mm) para os grupos de I ao VI, respectivamente. Nenhum grupo impediu a infiltração marginal; a técnica imediata mostrou os maiores valores de infiltração, diferente estatísticamente dos grupos II e V; nos grupos onde aplicou-se o perborato de sódio houve uma tendência a menor infiltração. Não houve diferença entre as demais técnicas e estas em relação ao grupo controle. / The effects of different bleaching techniques on the dental structures were assessed using microleakage tests. Sixty pre molars were used in this study according to the following procedures: group I – a cotton pellet saturated with 30% hydrogen peroxide was placed in the pulp chamber and on the buccal surface and heated to 42 oC three times of fifteen minutes each. This procedures was repeated three times. Group II - In the pulp chamber was inserted a paste of sodium perborate and 30% hydrogen peroxide for 21 days. Every seven days the material was renewed. Group III – The two techniques described above were associated. Group IV – 10% carbamide peroxide was applied on the external surfaces three hours per day during 21 days (home bleaching) Group V – Association of group II and IV techniques. Group VI- No treatments were performed in this group (Control). A CaOH2 paste was sealed in the pulp chamber for 10 days, the teeth were restored with Scotchbond Multi-uso Plus/Z-100, thermocycled and immersed in basic fucsin. The die penetration was determined in mm using the software Imagetool. The means (mm) of die penetration for groups I to VI were: 3,09; 1,83; 2,11; 2,36; 1,60; and 2,20. The microleakage occurred regardless the bleaching procedures. Group I technique exhibited higher die penetration when compared to groups II and V. The groups where sodium perborate was applied there was a trend of less die penetration.
159

Micromorfologia e resistência da união à dentina decídua tratada com dois sistemas adesivos estudo in vitro

Casagrande, Luciano January 2003 (has links)
O objetivo deste estudo in vitro foi avaliar a interação de dois sistemas adesivos (Scotchbond Multi-Purpose - 3M; Clearfil SE Bond - Kuraray) aplicados à dentina de dentes decíduos, através do ensaio de resistência da união à microtração, e da análise da micromorfologia da interface adesiva. Foram confeccionadas duas cavidades ocluso-proximais padronizadas (tipo slot vertical) na mesial e distal de dezoito molares decíduos hígidos. Cada um dos sistemas adesivos foi aplicado em uma das cavidades do mesmo dente. As cavidades foram restauradas com resina composta (Filtek Z 250 – 3M) pela técnica incremental, sendo cada camada fotopolimerizada por 20 s, utilizando uma fonte de luz visível (XL 2500 - 3M). Os dentes foram armazenados por uma semana em água destilada a 4o C e seccionados no sentido vestíbulo-lingual para análise isolada de cada restauração. Cada uma destas foi seccionada em fatias de 0,7 mm de espessura e, em seguida, efetuou-se uma constrição (1 mm) na região da interface de união (parede axial) para obtenção de uma área adesiva com aproximadamente 0,7 mm2. Os corpos-de-prova foram fixados isoladamente em um dispositivo conectado em uma máquina de ensaio universal (Instron – modelo 4411) e submetidos à tração com velocidade de 0,5 mm/min. As superfícies das secções fraturadas foram avaliadas ao MEV (Jeol –5600 LV) e categorizadas em relação aos padrões de fratura ocorridos. Adicionalmente, superfícies planas contendo a interface de união foram preparadas com lixas de carbureto de silício (granulação 1000) e polimento com pastas de diamante (6, 3, 1 e 0,25 µm). Após desidratação em sílica coloidal em temperatura ambiente por 24 h, as superfícies foram cobertas com liga de ouro e, a micromorfologia da união formada na parede axial das restaurações ocluso-proximais, analisadas ao MEV (Jeol –5600 LV). Os resultados do ensaio de resistência de união foram submetidos à análise estatística utilizando o teste t de student em nível de 5% de significância, e os tipos de fraturas e os aspectos micromorfológicos da interface adesiva submetidos à avaliação descritiva. Os valores médios de resistência de união dos adesivos Scothbond Multi-Purpose (21,84±9,90 MPa) e Clearfil SE Bond (25,19±5,33 MPa) não apresentaram diferenças estatisticamente significantes entre si (p=0,27). A análise do tipo de fratura revelou uma maior quantidade de falhas na região de dentina desmineralizada (G1: SMP) e na porção superior da camada híbrida (G2: CSE). A interface de união, em ambos os grupos, foi caracterizada pela formação da camada híbrida, projeção de prolongamentos resinosos adaptados à dentina e com direcionamento relacionado à disposição dos túbulos dentinários na área da cavidade avaliada.
160

Avaliação da Citotoxicidade dos Adesivos Adper™ Single Bond 2, Single Bond™Universal e Silorano Autocondicionante em Células Vero em Cultura

Catunda, Raisa Queiroz 31 January 2014 (has links)
Submitted by Etelvina Domingos (etelvina.domingos@ufpe.br) on 2015-04-08T19:09:06Z No. of bitstreams: 2 DISSERTAÇÃO RAISA QUEIROZ CATUNDA.pdf: 1302963 bytes, checksum: 19093f5f0f4d3fbf5a39dcf14f6805a1 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-04-08T19:09:06Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO RAISA QUEIROZ CATUNDA.pdf: 1302963 bytes, checksum: 19093f5f0f4d3fbf5a39dcf14f6805a1 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2014 / O objetivo deste estudo foi avaliar, in vitro, a citotoxicidade de três adesivos dentinários (Adper Single Bond 2 -SB, Sistema Adesivo Silorano-SAS e Single Bond Universal -SBU) em células Vero, após diferentes tempos de contato. Métodos: As células foram cultivadas a uma concentração de 2x105 células/ml por 24h e crescidas até formar uma monocamada subconfluente. As células Vero foram expostas a 25μl de extratos obtidos da imersão dos adesivos em meio de cultura (DMEM) por 24h, 48h e 72h, imediatamente após a polimerização. DMEM fresco foi utilizado como controle negativo e o metabolismo celular foi avaliado pelo método MTT [3-(4,5- Di-metiltiazol-2-il)-2,5- brometo difenil- tetrazolio)]. Os dados foram comparados estatisticamente através do teste ANOVA. Resultados: Os valores percentuais de viabilidade variaram de 94,2% em 72h (SBU) até 109,6% em 48h (SB). A média percentual de viabilidade após a exposição aos extrados de SB, SAS e SBU foram 103,2%, 100,63% e 97,43%, respectivamente. Não houve uma diferença significativa entre os grupos experimentais e o controle negativo (p= 0,342). Conclusões: Todos os adesivos testados neste estudo apresentaram nenhuma citotoxicidade à células Vero in vitro.

Page generated in 0.0291 seconds