• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • Tagged with
  • 41
  • 41
  • 34
  • 32
  • 18
  • 16
  • 15
  • 14
  • 14
  • 13
  • 13
  • 13
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

"Implante de stent revestido com paclitaxel em pacientes com infarto agudo do miocárdio em comparação com stent convencional: um estudo prospectivo, com avaliação clínica, angiográfica e ultra-sonográfica" / Paclitaxel-eluting stent implantation for acute myocardial infarction in comparison with conventional stenting : a clinical, angiographic, and IVUS prospective study

Martino, Fernando de 13 January 2006 (has links)
Fundamentos: Este estudo tem o objetivo de comparar os resultados clínicos e angiográficos de pacientes com infarto agudo do miocárdio(IAM) tratados com implante de stent revestido com paclitaxel (SRP) versus stent convencional. Métodos e população do estudo: Um grupo de 30 pacientes com infarto agudo do miocárdio foi tratados com stent revestido com paclitaxel (TaxusTM). Um grupo controle com 30 pacientes foi tratado com stent convencional (Express2 TM).Resultados: Aos 6,9±1,2 meses, não ocorreu morte, reinfarto ou trombose intra-stent. Entretanto, pacientes tratados com stent farmacológico tiveram um risco menor de reintervenção (3.3%% vs. 33.3%; p=0.006). A perda luminal tardia foi de 0.2±0.2 mm no grupo de SRP vs. 0.6±0.6 mm (p=0.03) no controle e a reestenose binária foi de 3.3% (RVP)vs. 33.3%(controle) (p=0.006). O percentual médio de obstrução neointimal em pacientes do grupo farmacológico foi de 4,7%±6,8%. Conclusões: O SRP se mostrou seguro e efetivo aos 7 meses em pacientes com IAM / This study aimed to compare the clinical and angiographic outcomes of patients with acute myocardial infarction (AMI) treated with paclitaxel eluting stent (PES) versus conventional stent implantation. Methods and Study Population: A group of 30 patients admitted with AMI was treated with PES (TaxusTM). A control group comprised 30 patients with a similar bare stent (Express IITM). Results: Baseline and procedural characteristics were similar between the PES and control groups. At 6.9±1.2 months, there were no deaths, re-AMI, or stent thrombosis. However, patients treated with PES had a lower risk of repeat revascularization (3.3%% vs. 33.3%; p=0.006). The angiographic late loss was 0.2±0.2 mm vs. 0.6±0.6 mm (p=0.03) and the binary restenosis rate was 3.3% vs. 33.3% (p=0.006) in the PES vs. controls respectively. The average percent neointimal obstruction in patients treated with PES was 4.7±6.8 %. Conclusions: PES appeared safe and effective at 7 months in patients AMI
12

"Implante de stent revestido com paclitaxel em pacientes com infarto agudo do miocárdio em comparação com stent convencional: um estudo prospectivo, com avaliação clínica, angiográfica e ultra-sonográfica" / Paclitaxel-eluting stent implantation for acute myocardial infarction in comparison with conventional stenting : a clinical, angiographic, and IVUS prospective study

Fernando de Martino 13 January 2006 (has links)
Fundamentos: Este estudo tem o objetivo de comparar os resultados clínicos e angiográficos de pacientes com infarto agudo do miocárdio(IAM) tratados com implante de stent revestido com paclitaxel (SRP) versus stent convencional. Métodos e população do estudo: Um grupo de 30 pacientes com infarto agudo do miocárdio foi tratados com stent revestido com paclitaxel (TaxusTM). Um grupo controle com 30 pacientes foi tratado com stent convencional (Express2 TM).Resultados: Aos 6,9±1,2 meses, não ocorreu morte, reinfarto ou trombose intra-stent. Entretanto, pacientes tratados com stent farmacológico tiveram um risco menor de reintervenção (3.3%% vs. 33.3%; p=0.006). A perda luminal tardia foi de 0.2±0.2 mm no grupo de SRP vs. 0.6±0.6 mm (p=0.03) no controle e a reestenose binária foi de 3.3% (RVP)vs. 33.3%(controle) (p=0.006). O percentual médio de obstrução neointimal em pacientes do grupo farmacológico foi de 4,7%±6,8%. Conclusões: O SRP se mostrou seguro e efetivo aos 7 meses em pacientes com IAM / This study aimed to compare the clinical and angiographic outcomes of patients with acute myocardial infarction (AMI) treated with paclitaxel eluting stent (PES) versus conventional stent implantation. Methods and Study Population: A group of 30 patients admitted with AMI was treated with PES (TaxusTM). A control group comprised 30 patients with a similar bare stent (Express IITM). Results: Baseline and procedural characteristics were similar between the PES and control groups. At 6.9±1.2 months, there were no deaths, re-AMI, or stent thrombosis. However, patients treated with PES had a lower risk of repeat revascularization (3.3%% vs. 33.3%; p=0.006). The angiographic late loss was 0.2±0.2 mm vs. 0.6±0.6 mm (p=0.03) and the binary restenosis rate was 3.3% vs. 33.3% (p=0.006) in the PES vs. controls respectively. The average percent neointimal obstruction in patients treated with PES was 4.7±6.8 %. Conclusions: PES appeared safe and effective at 7 months in patients AMI
13

Cintilografia do miocárdio com tecnécio 99m-MIBI associada à administração de adenosina em portadores de doença arterial coronária: implicações para a tomada de decisão / Adenosine myocardial perfusion SPECT with Tc- 99m - MIBI in patients with obstructive coronary artery disease: implications for making clinical decisions

Mastrocolla, Luiz Eduardo 25 November 2003 (has links)
A cintilografia do miocárdio com radioisótopos e associada à administração de vasodilatadores coronários, é método estabelecido para o diagnóstico e estratificação de risco da coronariopatia aterosclerótica obstrutiva, utilizando a angiografia coronária como padrão. As capacidades diagnóstica e prognóstica ótimas são habitualmente obtidas na presença de lesões graves, sendo que para para graus menores de obstrução, de caracterização mais difícil pela própria angiografia coronária, observa-se menor acurácia da prova cintilográfica. Para testar a hipótese de que a cintilografia com adenosina correlaciona-se com os diâmetros e áreas da luz arterial, estabelecidos pela angiografia coronária quantitativa (ACQ) e o ultra-som intracoronário (UIC), avaliando a repercussão funcional das lesões, optamos por avaliar o método em portadores de doença arterial coronária caracterizada como de difícil manejo dentro do processo de decisão clínica. Desta forma, submetemos 70 pacientes (P) consecutivos à cintilografia do miocárdio com 99mTc-MIBI associada à injeção de adenosina, com média de idades de 60,6 anos, sendo 55,7% do sexo masculino, excluindo-se aqueles com angina instável, infarto do miocárdio de evolução recente, bloqueio do ramo esquerdo e outras condições inerentes à realização da prova farmacológica. Estabelecemos como objetivos: 1) a associação dos resultados da prova com as variáveis obtidas da ACQ e UIC; 2) a determinação da acurácia da prova, definida em relação a valores de estenose porcentual do diâmetro da luz, iguais a 50% e obtidos à análise visual da angiografia (%E) e ACQ (%Est); do diâmetro mínimo da luz (DML) e da área mínima da luz (AML) no local de maior estreitamento, iguais a 1,5 mm e 4 mm2 respectivamente, obtidos à ACQ e ao UIC; e da área porcentual de obstrução (AO%), igual a 70%, ao UIC; 3) avaliar a segurança do método pela análise das respostas clínicas, hemodinâmicas e eletrocardiográficas (ECG) ao estímulo farmacológico. A angiografia de admissão evidenciou 105 lesões obstrutivas nos 70 P, com doença em um, dois e três ou mais vasos em 43 P (61,4%), 20 P (28,6%) e 7 P (10%) respectivamente, e envolvimento predominante da artéria descendente anterior. As médias dos valores de %E foram de 49,94% (DP 12,69) e de %Est de 44,20% (DP 10,37), com boa correlação entre os dois métodos (r=0,79). Os resultados da cintilografia foram expressos como variáveis dicotômicas, definindo provas normais e alteradas ou normais e isquêmicas, sendo então associados às médias das variáveis da angiografia e do UIC. Os achados de qualquer alteração da captação às imagens cintilográficas, de hipocaptação sugestiva de isquemia e de alterações do espessamento correlacionaram-se à maior AO% ao UIC. Adicionalmente, as respostas clínicas, do ECG e o resultado das imagens de perfusão foram considerados em conjunto, criando-se uma variável dicotômica para, da mesma forma, traduzir provas normais e alteradas ou isquêmicas. A presença de isquemia, avaliada pela análise global da prova, associou-se a menores DML e AML à ACQ e ao UIC: DML isquêmico x normal pela ACQ= 1,49 mm (DP 0,34) x 1,71 mm, (DP 0,49), p < 0,05; DML isquêmico x normal pelo UIC= 1,63 mm (DP 0,38) x 1,97 mm (DP 0,50), p < 0,05; AML isquêmica x normal pela ACQ= 3,74 mm2 (DP 1,78) x 5,00 mm2 (DP 2,65), p<0,05; e AML isquêmica x normal pelo UIC= 2,74 mm2 (DP 1,38) x 4,01 mm2 (DP 1,79), p < 0,05). A acurácia da prova, expressa pela sensibilidade (S), especificidade (E), valores preditivos positivo (VPP) e negativo (VPN) foi calculada em relação aos valores de corte estabelecidos das variáveis quantitativas. As respostas do ECG, discriminantes em relação à E%, mostraram S=37% e E=77%. As alterações da captação consideradas isquêmicas e associadas à AO% ao UIC evidenciaram S=75%; E=64%; VPP=43% e VPN=88%. Os resultados globais da prova que se mostraram discriminantes, apresentaram os seguintes índices: Método Variável S (%) E (%) VPP (%) VPN (%) ACQ DML 78 44 51 73 ACQ AML 71 43 65 50 UIC DML 93 39 50 90 UIC AML 83 56 86 50 Conclusões: Para a população estudada, a cintilografia com 99mTc-MIBI e injeção de adenosina correlaciona-se à AO% ao UIC, considerando-se as imagens de perfusão e de espessamento ventricular. Na avaliação dos resultados globais, caracterizados a partir da adição dos dados do ECG e das manifestações clínicas durante a injeção de adenosina às imagens, observa-se associação com os diâmetros e as áreas da luz nos locais de maior obstrução, obtidos à ACQ e ao UIC. Adicionalmente, pela análise das respostas clínicas, ECG e hemodinâmicas, o método mostrou-se seguro e factível / Radionuclide myocardial perfusion imaging (MPI) with 99mTechnetium - MIBI in combination with pharmacological vasodilation is used to detect ischemia and for the risk stratification of obstructive coronary artery disease (CAD), employing coronary angiography as gold standard. The best accuracy is found in presence of high-grade coronary stenosis, limited when less severity is seen. To test the hyphotesis that adenosine SPECT MPI correlates with coronary lesion lumen diameter and area dimensions by quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS), evaluating the functional significance of coronary stenosis, we intent to test the method in patients (P) with known coronary disease. Seventy consecutive P (55,7% male, mean age 60,6) were referred to adenosine SPECT 99mTc-MIBI. Were excluded those one with unstable angina, recent myocardial infarction, left bundle branch block, and any other conditions that makes the pharmacological stress impossible. The objectives were: 1) to establish the association between the clinical, EKG and scintigraphic findings with the QCA and IVUS variables; 2) to determine the accuracy of the test, based upon defined discriminant values of 50% luminal diameter narrowing by visual analysis of coronary angiography and QCA; minimum luminal diameter (MLD) and minimum luminal area (MLA) of 1,5 mm and 4 mm2 respectively, derived from QCA and IVUS and luminal percent area stenosis (AS%) of 70% by IVUS; 3) to determine the safety and feasibility of the method, throughout clinical, hemodinamic and electrocardiographic (EKG) responses to pharmacological vasodilation. The coronary angiography revealed 105 native artery lesions in 70 P, with one, two and multivessel disease in 43 p (61,4%), 20 p (28,6%) and 7 p (10%) respectively. Left anterior descending artery disease was present in 58%, 70% and 86% of the patients, respectively. Mean percent diameter stenosis values were 49,94% (SD 12,69) by visual analysis of angiography and 44,20% (SD 10,37) by QCA. Myocardial scintigraphy findings were defined as dicotomic variables categorized as normal x abnormal uptake or normal x reversible uptake; these findings were associated with visual, QCA and IVUS variables through mean comparison (t test). Chest pain during adenosine infusion was not related with greater stenosis severity, but ischemic EKG abnormalities were associated with different mean values when percent diameter stenosis derived from visual analysis was compared (p < 0,05). Therefore, any myocardial uptake abnormality, reversible uptake or any tickening abnormalities were correlated with AS% by IVUS (p< 0,05). Finally, the clinical, electrocardiographic and scintigraphic findings were considered together and categorized into global abnormal x normal response or global ischemic x normal response. Global ischemic response was associated to smaller mean values of MLD and MLA by QCA and IVUS: ischemic x normal MLD by QCA = 1,49 ± 0,34 mm x 1,71 ± 0,49 mm, p< 0,05; ischemic x normal MLD by IVUS = 1,63 ± 0,38 mm x 1,97 ± 0,50 mm, p<0,05; ischemic x normal MLA by QCA = 3,74 ± 1,78 mm2 x 5,00 ± 2,65 mm2, p<0,05; and ischemic x normal MLA by IVUS = 2,74 ± 1,38 mm2 x 4,01 ± 1,79 mm2, p<0,05). Sensitivity (S), Specificity (Sp), Predictive positive (PPV) and negative values (PNV) were calculated based upon discriminate values from visual, QCA and IVUS. The EKG response, related to percent diameter luminal stenosis by visual analysis of angiography showed S=37% and Sp=77%. Reversible uptake had S=75%; Sp=64%; PPV=43% and PNV=88%. The global ischemic findings that were discriminant are described bellow: Method Variable S (%) Sp (%) PPV (%) PNV (%) QCA DML 78 44 51 73 QCA AML 71 43 65 50 IVUS DML 93 39 50 90 IVUS AML 83 56 86 50 Considering the studied population with known coronary artery disease, perfusion and thickening adenosine SPECT results are associated with AS% by IVUS. When Clinical, EKG and scintigraphic findings are considered together as a dicotomic variable (ischemia x normal), correlation is observed between MLD and MLA by QCA and IVUS. Also, the method is considered feasible and safe, when clinical, hemodinamic and EKG abnormalities are evaluated
14

Efeito dos novos antiagregantes plaquetários prasugrel e ticagrelor administrados upstream sobre os achados angiográficos da angioplastia primária / Effect of new antiplatelet prasugrel and ticagrelor upstream therapy, on angiographic results of primary percutaneous coronary intervention

Mont\'Alverne Filho, José Ronaldo 03 August 2015 (has links)
Introdução. A dupla antiagregação plaquetária traz benefícios no tratamento do infarto agudo do miocárdio com supradesnivelamento do segmento ST (IAMSST). Há variabilidade intra e interindividual no uso do clopidogrel e isso influencia no benefício do seu uso nesse grupo de pacientes. O objetivo desta pesquisa foi avaliar os efeitos de novo antiagregantes plaquetários (prasugrel e ticagrelor) administrados na sala de emergência (\"upstream\") sobre o resultado angiográfico da angioplastia primária, levando em conta o fluxo coronariano TIMI, o blush miocárdico e a carga de trombo. Métodos. Foi realizado um ensaio clínico, randomizado, cego, com 131 pacientes admitidos com IAMSST. Todos os pacientes receberam ácido acetilsalicílico (AAS). Os pacientes foram randomizados para receber clopidogrel (n=44), prasugrel (n=41) ou ticagrelor (n=46) como dose de ataque ainda na emergência. Todos os pacientes foram submetidos a aspiração manual de trombos. Ao término do procedimento, o resultado angiográfico foi avaliado quanto ao fluxo TIMI, o blush miocárdico e a carga de trombo. Resultados. O fluxo coronariano TIMI >= 1 antes do procedimento foi observado mais frequentemente com o uso de ticagrelor (n = 10, 21,7%) do que com o clopidogrel (n = 1, 2,3%) e prasugrel (n = 5, 12,2%; p = 0,019). O fluxo TIMI coronária no fim do procedimento não diferiu significativamente entre os grupos (p = 0,101). Melhor resultado no que diz respeito ao blush miocárdico foi observada com prasugrel, que produziu um grau de blush III em 85,4% (n = 35) dos pacientes, em comparação com o clopidogrel (54,5%; n = 24) e ticagrelor (67,4%; n = 31; p = 0,025). A carga de trombo pré-procedimento foi maior no grupo de clopidogrel, em que 97,7% (n = 43) dos casos denotaram carga de trombo grau 4/5, enquanto 87,8% (n = 36) do grupo prasugrel tiveram respostas semelhantes, e 80,4% (n = 37) foram observadas no grupo ticagrelor (p = 0,03). Conclusão. Os novos antiagregantes plaquetários ticagrelor e prasugrel parecem exercer efeito sobre o resultado angiográfico dos pacientes submetidos a angioplastia primária. O uso do ticagrelor propiciou menor carga de trombo e um fluxo TIMI melhor no pré-procedimento e o uso do prasugrel ensejou melhor perfusão miocárdica analisada pelo blush miocárdico. Não houve diferença no fluxo angiográfico TIMI pós procedimento / Introduction. Dual antiplatelet therapy has benefits in the treatment of acute myocardial infarction with ST-segment elevation (STEMI). There is variability intra and inter individual in the use of clopidogrel and this influences the benefit of its use in this group of patients. The objective of this research was to evaluate the angiographic results of Upstream Clopidogrel, Prasugrel, or Ticagrelor For Patients Treated With Primary Angioplasty. Methods. A clinical trial was conducted, randomized, double blind, with 131 patients admitted with STEMI. All patients received acetylsalicylic acid (ASA). Patients were randomized to receive clopidogrel (n = 44), prasugrel (n = 41) or ticagrelor (n = 46) as loading dose even in emergency. All patients were submitted to manual thrombus aspiration. At the end of the procedure, the angiographic result was evaluated for TIMI flow, myocardial blush and thrombus burden. Results. A coronary TIMI flow >= 1 before the percutaneous procedure was observed more frequently with the use of ticagrelor (n=10, 21.7%) than with clopidogrel (n=1, 2.3%) and prasugrel (n=5, 12.2%; p=0.019). The coronary TIMI flow at the end of the procedure did not significantly differ between the groups (p=0.101). A better result with respect to myocardial blush was observed with prasugrel, which yielded a blush grade of III in 85.4% (n=35) of patients, compared with clopidogrel (54.5%; n=24) and ticagrelor (67.4%; n=31; p=0.025). The pre-procedural thrombus burden was found to be of a higher grade in the clopidogrel group, in which 97.7% (n=43) of the cases exhibited thrombus burdens grade 4/5, whereas 87.8% (n=36) of the prasugrel group had similar responses, and 80.4% (n=37) were observed in the ticagrelor group (p=0.03). Conclusions. The novel antiplatelet agents represented by ticagrelor and prasugrel appear to have effect on the angiographic outcome of patients undergoing primary angioplasty. The use of ticagrelor led to a smaller thrombus burden and better TIMI flow at the beginning of the procedure and the use of prasugrel produced a better myocardial perfusion analyzed by myocardial blush. There was no difference in post angioplasty TIMI flow
15

Avaliação tardia dos stents liberadores de Biolimus A9® pela tomografia de coerência óptica: análise da cobertura tecidual e da aposição das hastes / Long-term follow-up Biolimus A9TM stents with optical coherence tomography: strut apposition and tissue coverage analysis

Staico, Rodolfo 04 July 2011 (has links)
Introdução: Os stents farmacológicos (SF) de primeira geração surgiram com o intuito de reduzir as taxas de reestenose intra-stent e de revascularização da lesão-alvo, sendo mais eficazes quando comparados aos stents não-farmacológicos (SNF), porém com aumento de risco de trombose do stent (TS) muito tardia. A cobertura tecidual incompleta e a má aposição tardia das hastes dos stents podem estar vinculadas à TS. O SF de segunda geração BioMatrix®, que utiliza um polímero bioabsorvível, surgiu na expectativa de redução da TS. Devido à alta acurácia e reprodutibilidade e à análise precisa da cobertura tecidual e da aposição das hastes dos stents, a tomografia de coerência óptica (TCO) vem se tornando um método útil na análise desses aspectos. O objetivo desse estudo foi avaliar a cobertura tecidual e a aposição das hastes do SF BioMatrix® após longo período do implante. Métodos: Vinte pacientes submetidos ao implante do SF BioMatrix® (n = 15) ou do SNF S-Stent® (n = 5) foram acompanhados por um período mínimo de cinco anos e avaliados por meio da angiografia coronária quantitativa (ACQ), da ultrassonografia intracoronária (USIC) e da TCO. Para a análise estatística, foram utilizados os programas SPSS® versão 16.0 e SAS versão 9.2. O valor de p < 0,05 era considerado estatisticamente significante. As variáveis categóricas foram expressas em números absolutos e porcentuais e comparadas pelo teste exato de Fisher. As variáveis contínuas foram expressas em média e desvio padrão e/ou mediana e intervalo interquartílico e foram comparadas pelo teste não paramétrico de Mann-Whitney. Resultados: A ACQ demonstrou diferença, porém não significativa na perda tardia da luz entre o SF BioMatrix® e o S-Stent® [0,40 (0,21; 0,77) mm vs 0,68 (0,66; 0,82) mm, p = 0,205]. Os pacientes tratados com o SF BioMatrix® apresentaram porcentual de obstrução do stent significativamente menor quando comparados àqueles que receberam o S-Stent® [5,6 (4,4; 9,7)% vs 28,6 (24,7; 29,0)%, p =0,001]. A análise da TCO demonstrou 126 (8,7%) hastes não cobertas nos stents BioMatrix® e 23 (4,0%) nos S-Stents® (p = 0,297), estando a maioria delas bem apostas (117/126 e 21/23, respectivamente, p = 0,292). Apenas nove (0,6%) hastes nos SF e duas (0,4%) hastes nos SNF estavam simultaneamente sem cobertura tecidual e mal apostas (p = 0,924). No grupo BioMatrix®, apenas 1 (11,1%) paciente teve todas as hastes cobertas. Já no grupo S-Stent, 66,7% dos pacientes (2/3) apresentaram cobertura completa das hastes (p = 0,127). Conclusões: A avaliação tardia do SF BioMatrix® pela TCO mostrou cobertura tecidual e aposição em quase a totalidade de suas hastes, de maneira similar àquela encontrada nos SNF S-Stents®. / Introduction: First generation drug-eluting stents (DES) have emerged as a strategy to prevent in-stent restenosis and the need of target-vessel revascularization when compared to bare metal stents (BMS); but at the expense of a higher risk of very late stent thrombosis (ST). Uncovered and malapposed struts may be associated with both late and very late ST. It has been postulated that the second generation DES, the biolimus-eluting stent BioMatrixTM with biodegradable polymer, may reduce the incidence of ST. Given its high accuracy and reproducibility with precise analysis of the complete strut apposition and strut coverage, the optic coherence tomography (OCT) has been extensively used for stent analysis. The aim of this study was to assess the struts coverage and apposition of DES BioMatrixTM in a long-term follow up. Methods: Twenty patients undergoing a BioMatrixTM (n = 15) or BMS S-StentTM (n = 5) implantation were followed up for a period of at least five years and evaluated by means of OCT, quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS). All statistical analyses were performed using SPSSTM (v.16.0) and SAS (v.9.2) software. Statistical significance was considered at p values < 0.05. Categorical variables were expressed as counts and percentages, and continuous variables as mean SD and/or median and interquartile range. For per-patient level comparison, the difference between two stent types was evaluated by nonparametric Mann-Whitney U test while categorical variables were evaluated by the Fisher exact test. Results: QCA analysis showed no differences in the occurrence of intrastent late loss between the groups [0.40 (0.21; 0.77) mm vs 0.68 (0.66; 0.82) mm, p = 0.205 for BioMatrixTM and S-StentsTM, respectively]. The vessel, stent and lumen volumes assessed by IVUS after the procedure and 5 years later were similar between the two groups. Patients treated with BioMatrixTM had significantly less stent obstruction percentage when compared to those treated with S-StentTM [5.6 (4.4; 9.7)% vs 28.6 (24.7; 29.0)%, p = 0.001]. OCT analysis demonstrated 126 (8.7%) uncovered struts in the BioMatrixTM group compared to 23 (4.0%) in the S-StentsTM group (p = 0.297), being the majority of them well apposed (117/126 and 21/23, respectively, p = 0.292). Only 9 (0.6%) struts in the DES and 2 (0.4%) struts in the BMS groups were imultaneously uncovered and malapposed (p = 0.924). Among the BioMatrixTM patients, 55.6% (5/9) had more than 95% of covered struts and in only 1 (11.1%) patient all struts were covered. On the other hand, among the S-StentTM patients, 66.7% (2/3) had complete covered struts (p = 0.127). Conclusion: Long term assessment of DES BioMatrixTM by OCT showed tissue coverage and apposition in almost all struts, similary to those found in the BMS S-StentsTM.
16

Relação do SYNTAX Score com a liberação dos biomarcadores cardíacos após procedimentos de revascularização em pacientes portadores de doença arterial coronariana estável / Relationship between SYNTAX Score with the release of cardiac biomarkers after periprocedural revascularization for stable multivessel coronary disease

Azevedo, Diogo Freitas Cardoso de 19 October 2018 (has links)
Introdução: A liberação anormal de biomarcadores de injúria miocárdica após o procedimento de revascularização é, geralmente, associada a eventos clínicos adversos. Todavia, a elevação dos biomarcadores cardíacos após o procedimento de revascularização não foi associada à gravidade angiográfica da doença arterial coronariana (DAC). O objetivo do presente estudo é investigar a relação entre a complexidade angiográfica da DAC, avaliada pelo SYNTAX Score (SXScore), e a elevação dos biomarcadores cardíacos após procedimentos de revascularização. Métodos: Trata-se de uma análise post-hoc do estudo MASS V, unicêntrico, prospectivo e observacional de pacientes com DAC estável submetidos a procedimentos de revascularização. Foram realizadas dosagens seriadas de troponina I ultra (TnI-u) e creatinoquinase (CK) -MB antes e após os procedimentos. Os SXScores foram calculados antes dos procedimentos de revascularização, por cardiologistas intervencionistas, que desconheciam as características clínicas e laboratoriais dos pacientes. Resultados: Dos 202 pacientes estudados, 136 foram submetidos à revascularização do miocárdio (CRM) e 66, à intervenção coronária percutânea (ICP). A mediana do SXScore nos pacientes revascularizados foi 20,00 (IQR 15,00-26,00), sendo 39,00 (IQR 35,00-44,00) no grupo SXScore alto e 19,0 (IQR 14,00-24,00) no grupo SXScore baixo/intermediário (p < 0,0001). Houve correlações significativas entre o SXScore e as medianas dos picos de TnI-u (r = 0,18, p = 0,009) e CK-MB (r = 0,24, p = 0,001), após procedimentos de revascularização. As medianas dos picos de TnI (p = 0,034) e CK-MB (p = 0,004), após procedimentos, foram maiores nos pacientes com SXScore alto ( >= 33) as aos daqueles com SXScore baixo/intermediário ( < 33). Além disso, a liberação de TnI em 6 horas (p = 0,002), 12 horas (p = 0,008) e 24 horas (p = 0,039), foi maior no grupo SXScore alto que no grupo SXscore baixo/intermediário ( < 33), bem como a liberação de CK-MB em 6 horas (p < 0,0001), 12 horas (p < 0,0001), 24 horas (p = 0,001), 36 horas (p = 0,007), 48 horas (p = 0,008) e 72 horas (p = 0,023), nos mesmos grupos. Após análise multivariada em um modelo incluindo variáveis clínicas, angiográficas, demográficas e laboratoriais, o SXScore alto permaneceu como preditor independente da liberação de CK-MB e TnI acima da mediana. Conclusão: O aumento da liberação de biomarcadores cardíacos foi significativamente associado à extensão da aterosclerose identificada pelo SYNTAX Score. Além disso, o SYNTAX Score alto demonstrou ser preditor independente para a elevação da CKMB acima da mediana mesmo quando ajustado a covariáveis / Background: Abnormal cardiac biomarkers release after revascularization procedure has been associated with worse clinical outcomes. However, levels of myocardial biomarkers after revascularization procedural have not been associated with the severity of coronary artery disease (CAD). Our aim was to investigate the relationship between angiographic complexity of CAD as assessed by SYNTAX Score (SXScore) and cardiac biomarkers elevation after revascularization procedures. Methods: This is a post-hoc analyses of MASS V trial, which was a single-center, prospective and observational study among patients with stable CAD who underwent revascularization procedures. High sensitivity troponin (TnI) and creatinekinase (CK) -MB were assessed before and after procedures. Baselines SXscores were calculated by angiographic laboratory investigators blinded to patient characteristics. Results: Of the 202 patients studied, 136 underwent coronary artery bypass grafting (CABG) and 66 percutaneous coronary intervention (PCI). The median SXScore was 20.00 (IQR 15.00-26.00) in revascularized patients, 39.00 (IQR 35.00-44.00) in the high SXscore group and 19.0 (IQR 14.0024.00) in low/mid SXScore group (p < 0.0001). There were positive correlations between SXScore and median peaks after procedural TnI (r =0.18, p=0.009) and CK-MB (r =0.24, p=0.001) levels. In patients with high X (>= 33) k f procedural TnI(p=0.034) and CK-MB (p=0.004) levels were higher than low/mid SXScore( < 33) and the release of TnI at 6 hours (p = 0.002), 12 hours (p=0.008) and 24 hours (p=0.039), was higher in high SXScore group than low/mid SXScore ( < 33), as well as, the release of CK-MB at 6 hours (p < 0.0001), 12 hours (p < 0.0001), 24 hours (p=0.001), 36 hours (p=0.007), 48 hours (p=0.008) and 72 hours (p=0.023), in the same groups. After multivariate analysis, in a model including clinical, angiographic, demographic and laboratorial variables, high SXScore was a significant independent correlate of release of CK-MB and TnI peaks higher than median. Conclusion: The increase of release of cardiac biomarkers was significantly associated with the extent of atherosclerosis identified by the SYNTAX Score. Besides, high SYNTAX Score remained an independent predictor for elevation of CKMB above the median even when adjusted for covariates
17

Estudo dos determinantes de doença arterial coronária grave em pacientes hipertensos com indicação de arteriografia renal por suspeita de estenose de artéria rena / Determinants of severe coronary artery disease in hypertensive patients with indications of renal angiography for suspected renal artery stenosis

Macêdo, Thiago Andrade de 23 April 2012 (has links)
INTRODUÇÃO: Em pacientes hipertensos com suspeita de doença arterial coronária (DAC), indicações para a realização de arteriografia renal no mesmo procedimento da cinecoronariografia estão bem estabelecidas. Entretanto, em hipertensos com suspeita de estenose de artéria renal (EAR) com indicação de arteriografia renal, não estão bem definidos os determinantes da presença de DAC grave. OBJETIVOS: Avaliar a prevalência e os determinantes de DAC grave em pacientes hipertensos com indicação de arteriografia renal por suspeita de EAR. METODOLOGIA: Oitenta e dois pacientes com suspeita clínica de EAR foram submetidos à cinecoronariografia e arteriografia renal no mesmo procedimento. Lesão arterial significativa em artérias renal e/ou coronária foi definida por obstrução luminal maior ou igual a 70%. RESULTADOS: Obstrução luminal significativa, tanto em artéria coronária quanto em renal, foi encontrada em 39% dos pacientes. Os pacientes com DAC grave apresentaram idade mais avançada (63±12 vs. 56±13 anos; p=0,03), maior prevalência de angina (41 vs. 16%; p=0,013), maior diâmetro do átrio esquerdo (44,7 vs. 40,6mm; p=0,005) e maior velocidade de onda de pulso (12,6 vs. 10,7 m/s, p=0,02), comparados com os pacientes sem DAC grave. A presença de EAR significativa esteve associada a uma maior prevalência de DAC grave comparada a pacientes sem a lesão (66% vs. 22%; p<0,001). A análise multivariada demonstrou que EAR70% esteve associada com DAC grave de maneira independente (OR: 11,48; 95%CI 3,2-40,2; p<0,001), mesmo em pacientes sem angina (OR: 13,48; 95%CI 2,6-12,1; p<0,001). CONCLUSÃO: Há elevada prevalência de doença coronária grave em pacientes hipertensos com estenose de artéria renal significativa. A presença de estenose maior ou igual a 70%, verificada em arteriografia renal, é preditor forte e independente para a presença de DAC grave, mesmo na ausência de angina / INTRODUCTION: In patients with suspected coronary artery disease (CAD), indications for performing coronary and renal angiography at the same setting are well established. However, in hypertensive patients with suspected renal artery stenosis (RAS) with indication for renal angiography, it is not well defined the determinants of the presence of severe CAD. OBJECTIVES: We aimed to evaluate the prevalence and determinants of severe CAD in hypertensive patients referred to renal angiography for the diagnosis of RAS. METHODS: Eighty-two consecutive patients with high clinical risk for RAS systematically underwent renal angiography and coronary angiography at the same procedure. Significant RAS and CAD were defined as arterial luminal obstruction 70%. RESULTS: Either significant RAS or significant CAD were present in 32/82 patients (39%). Patients with severe CAD were older (63±12 vs. 56±13 years, p=0.03), had more angina (41 vs. 16%; p=0.013), higher left atrial diameter (44.7 vs. 40,6mm; p=0.005), and higher pulse wave velocity (12.6 vs. 10.7 m/s); p=0.02) compared to patients without significant CAD. Significant RAS was associated with an increased prevalence of severe CAD compared to patients without the lesion (66% vs. 22%, respectively; p<0.001). Binary logistic regression analysis showed that RAS 70% was independently associated with severe CAD (OR: 11.48; 95%CI 3.2-40.2; p<0.001), even in patients without angina (OR: 13.48; 95%CI 2.6-12.1; p<0.001). CONCLUSION: The prevalence of severe CAD in hypertensive patients with significant RAS is high. The presence of RAS 70%, diagnosed by renal angiography, is a strong and useful predictor to identify severe CAD, independently of the presence of angina
18

Visibilização de artérias coronárias epicárdicas em imagens ecocardiográficas tridimensionais com contraste de microbolhas / Visualization of the epicardial coronary arteries in microbubble contrasted tri-dimensional echocardiographic images

Lage, Danilo Meneses 01 October 2010 (has links)
Com os avanços tecnológicos das últimas décadas, a ecocardiografia surgiu como uma alternativa de diagnóstico por imagem de relativo baixo custo, que não faz uso de energia ionizante ou radioativa. Recentemente, o advento dos agentes de contraste por microbolhas e dos transdutores matriciais tornou possível a visualização tridimensional da anatomia das artérias coronárias. Neste projeto, é proposta a avaliação de métodos de segmentação capazes de visibilizar as artérias coronárias epicárdicas em Imagens de ecocardiografias tridimensionais com contraste de microbolhas. Esse é o primeiro passo para o desenvolvimento de ferramentas computacionais eficazes e eficientes na assistência não invasiva ao acompanhamento do quadro clínico de pacientes, do diagnóstico ao pós-operatório. Propõe-se, uma metodologia que facilite o acesso às coronárias a partir de imagens de ecocardiografia tridimensionais com aplicação de contraste por microbolhas. Dentre as metodologias estudadas, as técnicas baseadas na teoria Fuzzy Connectedness (FC) foram identificadas como as mais promissoras. Estudou-se, portanto, seis abordagens baseadas nessa teoria, três delas são descritas na literatura (Generalized FC GFC; Relative FC RFC; Dynamic Weighted FC DyWFC) e três proposições originais (Area of Search FC ASFC; Ultrasound-k FC USFC; Guided FC GuFC). Para avaliar a acurácia desses algoritmos, confeccionou-se um conjunto de imagens simuladas, composto por 360 imagens, e selecionou-se um conjunto de imagens de exames reais, composto de 10 imagens reais de pacientes com quadro de Cardiomiopatia Hipertrópica. Para as imagens simuladas, os métodos da literatura alcançaram acurácia de 85,5% para GFC, 89,5% para RFC e 92,0% para DyWFC. Enquanto isso, os métodos propostos alcançaram acurácia de 88,9% para ASFC, 91,7 % para USkFC e 95,2% para GuFC. Para as imagens reais, os métodos convergiram para uma segmentação satisfatória quanto à usabilidade na clínica médica. Esses resultados demonstraram, ainda, o melhor desempenho do método proposto GuFC ante os demais. Dessa forma, ele se torna um candidato para ingressar na etapa de segmentação de uma ferramenta computacional para visibilização das coronárias epicárdicas no futuro / With the technological advances of recent decades, echocardiography has emerged as a relatively low cost imaging diagnostic alternative, that does not use ionizing or radioactive energy. Lately, the advent of microbubble-based contrast agents and array transducers turned possible the visualization of three-dimensional coronary arteries anatomy. The present project proposes to evaluate segmentation methods able to deal with the visualization of the epicardial coronary arteries in microbubble-based three-dimensional echocardiography images. This is the first step towards the development of effective and efficient computational tools for diagnosis and prognosis assistance of cardiac pacient. We propose a methodology to facilitate the access to epicardial coronary arteries in tridimensional echocardiographic images. Among the studied approaches, Fuzzy Connectednessbased segmentation methods were identified as being the most promising. We studied six approaches based on this theory, three of them are described in the literature (Generalized FC GFC; Relative FC RFC; Dynamic Weighted FC DyWFC) and three original contributions (Area of Search FC ASFC; Ultrasound-k FC USFC; Guided FC GuFC). To evaluate the accuracy of these algorithms, a set composed of 360 simulated images were created. We also selected a set of 10 real images, composed of hypertrophic cardiomyopathy patients. For simulated images set, the methods of literature achieved accuracy of 85.5% for GFC, 89,5% for RFC and 92,0% for DyWFC, meanwhile, the proposed method achieved accuracy of 88.9% for ASFC, 91,7 % for USkFC and 95,2% for GuFC. Using the real images set, the methods converged to good results for clinical purposes. These results demonstrate that the proposed method GuFC has shown a better performance than the others, becoming a candidate to the segmentation step in a computational tool for coronary arteries visualization in the future
19

Efeito dos novos antiagregantes plaquetários prasugrel e ticagrelor administrados upstream sobre os achados angiográficos da angioplastia primária / Effect of new antiplatelet prasugrel and ticagrelor upstream therapy, on angiographic results of primary percutaneous coronary intervention

José Ronaldo Mont\'Alverne Filho 03 August 2015 (has links)
Introdução. A dupla antiagregação plaquetária traz benefícios no tratamento do infarto agudo do miocárdio com supradesnivelamento do segmento ST (IAMSST). Há variabilidade intra e interindividual no uso do clopidogrel e isso influencia no benefício do seu uso nesse grupo de pacientes. O objetivo desta pesquisa foi avaliar os efeitos de novo antiagregantes plaquetários (prasugrel e ticagrelor) administrados na sala de emergência (\"upstream\") sobre o resultado angiográfico da angioplastia primária, levando em conta o fluxo coronariano TIMI, o blush miocárdico e a carga de trombo. Métodos. Foi realizado um ensaio clínico, randomizado, cego, com 131 pacientes admitidos com IAMSST. Todos os pacientes receberam ácido acetilsalicílico (AAS). Os pacientes foram randomizados para receber clopidogrel (n=44), prasugrel (n=41) ou ticagrelor (n=46) como dose de ataque ainda na emergência. Todos os pacientes foram submetidos a aspiração manual de trombos. Ao término do procedimento, o resultado angiográfico foi avaliado quanto ao fluxo TIMI, o blush miocárdico e a carga de trombo. Resultados. O fluxo coronariano TIMI >= 1 antes do procedimento foi observado mais frequentemente com o uso de ticagrelor (n = 10, 21,7%) do que com o clopidogrel (n = 1, 2,3%) e prasugrel (n = 5, 12,2%; p = 0,019). O fluxo TIMI coronária no fim do procedimento não diferiu significativamente entre os grupos (p = 0,101). Melhor resultado no que diz respeito ao blush miocárdico foi observada com prasugrel, que produziu um grau de blush III em 85,4% (n = 35) dos pacientes, em comparação com o clopidogrel (54,5%; n = 24) e ticagrelor (67,4%; n = 31; p = 0,025). A carga de trombo pré-procedimento foi maior no grupo de clopidogrel, em que 97,7% (n = 43) dos casos denotaram carga de trombo grau 4/5, enquanto 87,8% (n = 36) do grupo prasugrel tiveram respostas semelhantes, e 80,4% (n = 37) foram observadas no grupo ticagrelor (p = 0,03). Conclusão. Os novos antiagregantes plaquetários ticagrelor e prasugrel parecem exercer efeito sobre o resultado angiográfico dos pacientes submetidos a angioplastia primária. O uso do ticagrelor propiciou menor carga de trombo e um fluxo TIMI melhor no pré-procedimento e o uso do prasugrel ensejou melhor perfusão miocárdica analisada pelo blush miocárdico. Não houve diferença no fluxo angiográfico TIMI pós procedimento / Introduction. Dual antiplatelet therapy has benefits in the treatment of acute myocardial infarction with ST-segment elevation (STEMI). There is variability intra and inter individual in the use of clopidogrel and this influences the benefit of its use in this group of patients. The objective of this research was to evaluate the angiographic results of Upstream Clopidogrel, Prasugrel, or Ticagrelor For Patients Treated With Primary Angioplasty. Methods. A clinical trial was conducted, randomized, double blind, with 131 patients admitted with STEMI. All patients received acetylsalicylic acid (ASA). Patients were randomized to receive clopidogrel (n = 44), prasugrel (n = 41) or ticagrelor (n = 46) as loading dose even in emergency. All patients were submitted to manual thrombus aspiration. At the end of the procedure, the angiographic result was evaluated for TIMI flow, myocardial blush and thrombus burden. Results. A coronary TIMI flow >= 1 before the percutaneous procedure was observed more frequently with the use of ticagrelor (n=10, 21.7%) than with clopidogrel (n=1, 2.3%) and prasugrel (n=5, 12.2%; p=0.019). The coronary TIMI flow at the end of the procedure did not significantly differ between the groups (p=0.101). A better result with respect to myocardial blush was observed with prasugrel, which yielded a blush grade of III in 85.4% (n=35) of patients, compared with clopidogrel (54.5%; n=24) and ticagrelor (67.4%; n=31; p=0.025). The pre-procedural thrombus burden was found to be of a higher grade in the clopidogrel group, in which 97.7% (n=43) of the cases exhibited thrombus burdens grade 4/5, whereas 87.8% (n=36) of the prasugrel group had similar responses, and 80.4% (n=37) were observed in the ticagrelor group (p=0.03). Conclusions. The novel antiplatelet agents represented by ticagrelor and prasugrel appear to have effect on the angiographic outcome of patients undergoing primary angioplasty. The use of ticagrelor led to a smaller thrombus burden and better TIMI flow at the beginning of the procedure and the use of prasugrel produced a better myocardial perfusion analyzed by myocardial blush. There was no difference in post angioplasty TIMI flow
20

Estudo dos determinantes de doença arterial coronária grave em pacientes hipertensos com indicação de arteriografia renal por suspeita de estenose de artéria rena / Determinants of severe coronary artery disease in hypertensive patients with indications of renal angiography for suspected renal artery stenosis

Thiago Andrade de Macêdo 23 April 2012 (has links)
INTRODUÇÃO: Em pacientes hipertensos com suspeita de doença arterial coronária (DAC), indicações para a realização de arteriografia renal no mesmo procedimento da cinecoronariografia estão bem estabelecidas. Entretanto, em hipertensos com suspeita de estenose de artéria renal (EAR) com indicação de arteriografia renal, não estão bem definidos os determinantes da presença de DAC grave. OBJETIVOS: Avaliar a prevalência e os determinantes de DAC grave em pacientes hipertensos com indicação de arteriografia renal por suspeita de EAR. METODOLOGIA: Oitenta e dois pacientes com suspeita clínica de EAR foram submetidos à cinecoronariografia e arteriografia renal no mesmo procedimento. Lesão arterial significativa em artérias renal e/ou coronária foi definida por obstrução luminal maior ou igual a 70%. RESULTADOS: Obstrução luminal significativa, tanto em artéria coronária quanto em renal, foi encontrada em 39% dos pacientes. Os pacientes com DAC grave apresentaram idade mais avançada (63±12 vs. 56±13 anos; p=0,03), maior prevalência de angina (41 vs. 16%; p=0,013), maior diâmetro do átrio esquerdo (44,7 vs. 40,6mm; p=0,005) e maior velocidade de onda de pulso (12,6 vs. 10,7 m/s, p=0,02), comparados com os pacientes sem DAC grave. A presença de EAR significativa esteve associada a uma maior prevalência de DAC grave comparada a pacientes sem a lesão (66% vs. 22%; p<0,001). A análise multivariada demonstrou que EAR70% esteve associada com DAC grave de maneira independente (OR: 11,48; 95%CI 3,2-40,2; p<0,001), mesmo em pacientes sem angina (OR: 13,48; 95%CI 2,6-12,1; p<0,001). CONCLUSÃO: Há elevada prevalência de doença coronária grave em pacientes hipertensos com estenose de artéria renal significativa. A presença de estenose maior ou igual a 70%, verificada em arteriografia renal, é preditor forte e independente para a presença de DAC grave, mesmo na ausência de angina / INTRODUCTION: In patients with suspected coronary artery disease (CAD), indications for performing coronary and renal angiography at the same setting are well established. However, in hypertensive patients with suspected renal artery stenosis (RAS) with indication for renal angiography, it is not well defined the determinants of the presence of severe CAD. OBJECTIVES: We aimed to evaluate the prevalence and determinants of severe CAD in hypertensive patients referred to renal angiography for the diagnosis of RAS. METHODS: Eighty-two consecutive patients with high clinical risk for RAS systematically underwent renal angiography and coronary angiography at the same procedure. Significant RAS and CAD were defined as arterial luminal obstruction 70%. RESULTS: Either significant RAS or significant CAD were present in 32/82 patients (39%). Patients with severe CAD were older (63±12 vs. 56±13 years, p=0.03), had more angina (41 vs. 16%; p=0.013), higher left atrial diameter (44.7 vs. 40,6mm; p=0.005), and higher pulse wave velocity (12.6 vs. 10.7 m/s); p=0.02) compared to patients without significant CAD. Significant RAS was associated with an increased prevalence of severe CAD compared to patients without the lesion (66% vs. 22%, respectively; p<0.001). Binary logistic regression analysis showed that RAS 70% was independently associated with severe CAD (OR: 11.48; 95%CI 3.2-40.2; p<0.001), even in patients without angina (OR: 13.48; 95%CI 2.6-12.1; p<0.001). CONCLUSION: The prevalence of severe CAD in hypertensive patients with significant RAS is high. The presence of RAS 70%, diagnosed by renal angiography, is a strong and useful predictor to identify severe CAD, independently of the presence of angina

Page generated in 0.3029 seconds