• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 50
  • 2
  • Tagged with
  • 53
  • 53
  • 20
  • 18
  • 16
  • 15
  • 14
  • 12
  • 12
  • 11
  • 10
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Conforto e "stress" termico em industrias : pesquisas efetuadas nas regiões de Joinville, SC e Campinas, SP

Hackenberg, Ana Mirthes 15 May 2000 (has links)
Orientador: Jose Tomaz Vieira Pereira / Tese (doutorado) - Universidade Estadual de Campinas. Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-27T05:18:00Z (GMT). No. of bitstreams: 1 Hackenberg_AnaMirthes_D.pdf: 28706243 bytes, checksum: 75da923dcca548963a0d5cc4f20526fd (MD5) Previous issue date: 2000 / Resumo: O presente trabalho apresenta uma avaliação de algumas normas ISO de conforto e stress térmico em ambientes fabris no clima sub-tropical. Estas normas tiveram origem em trabalhos de pesquisa desenvolvidos em climas mos no hemisfério norte. Estudos recentes em climas tropicais, na Ásia, na Austrália e no Brasil contestam alguns limites de conforto térmico indicados nestas normas, afirmando que são adequados para climas mos, devendo ser um pouco mais altos para climas quentes. O trabalho teve como objetivo avaliar a sensação térmica dos trabalhadores industriais em duas regiões com climas diferentes e edificações com características construtivas e sistemas de controle térmico também diferentes. A metodologia adotada foi a proposta pela ISO, com medições dos parâmetros ambientais complementado com a realização de pesquisa entre os usuários, contendo questões sobre sensação térmica, características pessoais, atividade exerci da e vestimenta utilizada. Foram avaliadas as influências ambientais, atividade e vestimenta nas respostas dos trabalhadores e a aplicabilidade do questionário da ISO 10551 para diferentes culturas em que foi originado / Abstract: The present work presents an evaluation of the use of some norms cornfort ISO and thermal stress in industrial atmospheres in the sub-tropical climate. These norms had origin in research works developed in cold climates in Northem Hemisphere. Recent studies in tropical climates, in Asia, in Australia and in Brazil they answer some limits of thermal comfort indicated in these norms, affirming that they are appropriate for cold climates, should be a little higher for hot climates. The work had as objective evaluates the industrial workers' thermal sensation in two areas with different climates and constructions with constructive characteristics and systems of thermal control also different. The adopted methodology was the proposal for ISO, with measurements of the environrnental parameters complemented with the research accomplishment among the users, containing subjects about thermal sensation, personal characteristics, exercised activity and used vestiment. They were appraised the environrnental influences, activity and vestiment in the workers' answers and the aplicabilidade of the questionnaire of ISO 10551 for different cultures in that was originated. / Doutorado / Doutor em Planejamento de Sistemas Energéticos
32

Desempenho termoenergético da utilização de telhado vegetal em edificação no clima amazônico

MARINHO, Dircirene Tavares 19 March 2013 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-05-26T11:25:37Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesempenhoTermoenergeticoUtilizacao.pdf: 9405332 bytes, checksum: 6db1c2227ae6d91753b4e18c4f06cc0c (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-06-02T13:14:00Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesempenhoTermoenergeticoUtilizacao.pdf: 9405332 bytes, checksum: 6db1c2227ae6d91753b4e18c4f06cc0c (MD5) / Made available in DSpace on 2017-06-02T13:14:00Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesempenhoTermoenergeticoUtilizacao.pdf: 9405332 bytes, checksum: 6db1c2227ae6d91753b4e18c4f06cc0c (MD5) Previous issue date: 2013-03-19 / O desempenho termoenergético de toda obra da construção civil decorre da tomada de decisões na fase projetual e as caracteristicas termofisicas dos materiais empregados devem ser considerados. O fenomeno termofísico da inércia presente nos telhados vegetais oferece resistencia ao transporte de massa termica para o interior da edificação, reduzindo a demanda de energia elétrica necessaria para seu acondicionamento climático; ao mesmo tempo, o baixo albedo da vegetação dos telhados vegetais contribui para mitigar os efeitos das ilhas de calor em ambientes urbanos. O necessário estudo bioclimático e o microclimático determinarão a escolha dos materiais construtivos adequados, especialmente no que tange à proteção de superfícies da envoltória expostas à carga térmica solar. Este trabalho irá tratar da comprovação experimental do desempenho termoenergético de uma edificação coberta com grama em local onde predomina a vegetação, no Parque de Ciência e Tecnologia do Guamá, Campus Universitário da Universidade Federal do Pará. O objetivo é a analise da atenuação dos picos de calor decorrente da inércia térmica dos materiais utilizados, inferindo desempenho energético pela redução do uso de refrigeração ativa. Foram caracterizados os microclimas externos e internos através de valores obtidos de temperatura e umidade relativa do ar, assim como a evolução das condições ambientais internas em duas fases, com a laje descoberta e após com a aplicação do telhado vegetal. Os resultados indicam favorável desempenho do telhado vegetal na redução do fluxo de calor através da laje, apresentando potencial redução na temperatura do ar interior e a conseqüente eficiência energética em edificações no clima amazônico. / The thermoenergetic performance of all construction work stems from the decisionmaking of the initial phase, and the thermo-physical characteristics of the materials used must be considered. The thermo-physical phenomenon of inertia in the roof vegetable offers resistance to the transport of thermic charge to inside the edification, reducing the demand of the electric energy needed to its climatic conditioning. At the same time, the low albedo of the roof vegetable contributes to mitigate the effects of the heat islands in urban environments. The bioclimatic and microclimatic study needed will determine the choice of the suitable construction materials, especially regarding the protection of surfaces exposed to solar heat load. This work deals with the experimental verification of the thermoenergetic performance of a room covered with grass in a place where the vegetation is predominant, in the Parque de Ciência e Tecnologia do Guamá, Campus da Universidade Federal do Pará. The key objective was to examine the thermal response of the slab by proving mitigation of heat spikes by physical phenomenon of thermal inertia, implying favorable results of energy performance by reducing the use of active cooling. It was performed preliminary characterization of the indoor and outdoor microclimate through the obtained values of temperature and relative humidity of air, and observed the evolution of internal environmental conditions in two phases, with the slab discovered and after application of vegetation. The quantitative results showed favorable performance of the roof vegetation in the moderation of heat flow through the slab, contributing to the reduction of the temperature of indoor air and consequent energy efficiency in buildings in Amazonian climate.
33

Estudos de tipologias habitacionais amazônicas com análise ambiental para fins projetuais

SAMPAIO, Trycia Guerreiro 01 April 2013 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-05-26T16:02:18Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudoTipologiasHabitacionais.pdf: 6433957 bytes, checksum: 0a05dfebd5c2cc49e9fbde9b0b0221dd (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-06-05T16:46:20Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudoTipologiasHabitacionais.pdf: 6433957 bytes, checksum: 0a05dfebd5c2cc49e9fbde9b0b0221dd (MD5) / Made available in DSpace on 2017-06-05T16:46:20Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudoTipologiasHabitacionais.pdf: 6433957 bytes, checksum: 0a05dfebd5c2cc49e9fbde9b0b0221dd (MD5) Previous issue date: 2013-04-01 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Investigam-se tipologias habitacionais amazônicas por meio de uma visão integrada entre as condições físico-ambientais e a sensação térmica dos usuários. As tipologias habitacionais selecionadas referem-se a espaços espontaneamente produzido em áreas, continental e insular do município de Belém (PA), e também a espaços formalmente produzidos em área de reassentamento urbano, na chamada Vila da Barca. A avaliação ambiental proposta, oportuniza a investigação sobre solução e vivência espacial em tipologias culturalmente construídas para subsidiar propostas de habitação social em ambiente amazônico em que pese a valorização dos efeitos humanos e ambientais da intervenção habitacional. A estratégia metodológica adotada abrange métodos qualitativos e quantitativos. Utiliza instrumentos de consulta aplicados aos moradores das habitações estudadas e também o uso de ferramenta computacional, o EnergyPlus. Os resultados encontrados apontam que as condições ambientais e de bem-estar percebidas pelos moradores, são contraditórias frente as condições ambientais atmosféricas locais, pois apesar dos dados apontarem temperaturas elevadas, com mais de 60% das horas anuais fora das condições de conforto, as respostas dos questionários obtidas com os moradores foram positivas em relação a sua satisfação quanto as condições de moradia, principalmente, os moradores das tipologias habitacionais localizadas na área insular do município de Belém. / The objective is to study the housing typologies Amazon through an integrated view between the physical and environmental conditions and thermal sensation of users. The housing typologies selected refer to spaces spontaneously produced in areas, continental and insular, in Belém (PA), and also the spaces formally produced in urban resettlement area, a Vila da Barca. The environmental assessment favors the proposed solution and research experience in spatial typologies culturally constructed to support proposals for social housing in the Amazon environment, despite the appreciation of human and environmental effects of housing assistance. The strategy adopted includes qualitative and quantitative methods. Uses consultation tools applied to residents of the dwelling and also studied the use of computational tools, the EnergyPlus. The results indicate environmental conditions and well-being perceived by residents in the face of conflicting local weather conditions, because despite the high temperatures present data with over 60% of annual hours outside the comfort conditions, the questionnaire responses were obtained with the locals positive in relation to the same as satisfaction with living conditions, especially the residents of housing typologies located in the island municipality of Bethlehem.
34

Análise da relação entre os parâmetros arquitetônicos, o conforto térmico e a produtividade em escritórios com ventilação natural / Analysis of relationship between parameters architectural, thermal comfort and productivity in office with natural ventilation

Oliveira, Etianne Alves Souza de 16 June 2015 (has links)
O objetivo deste estudo foi encontrar correlação entre o conforto térmico, produtividade de trabalhadores e variáveis arquitetônicas de escritórios naturalmente ventilados. O problema proposto foi: quais as variáveis arquitetônicas de ambientes de escritórios naturalmente ventilados podem interferir nas variáveis de conforto, a ponto de influenciar a produtividade dos trabalhadores? O referencial teórico envolveu os seguintes temas: conforto térmico, arquitetura das construções, ergonomia e avaliação de desempenho. A abordagem metodológica usada foi estudo transversal de natureza aplicada, quantitativa, descritiva e exploratória, fazendo uma análise causa-efeito, através de um estudo de caso. Na coleta de dados foram utilizados dois instrumentos para medir as variáveis térmicas, duas avaliações subjetivas, uma para medir o conforto térmico e outra para medir a produtividade subjetiva dos trabalhadores, e levantamento de dimensões físicas do ambiente construído, onde cada trabalhador desempenhava suas tarefas. A amostra é composta por 04 empresas, 10 ambientes arquitetônicos e 25 trabalhadores de escritório, e totalizam 45 avaliações em diferentes períodos de tempo. A análise estatística envolveu a identificação de outliers; normalidade e correlação entre as variáveis. Como resultados, 2% dos valores de produtividade podem ser explicados pelos níveis de conforto térmico calculado. As correlações entre as variáveis arquitetônicas e a variável conforto térmico apresentaram correlações baixas, sendo que a única que foi estatisticamente significativa foi a porcentagem de janela envidraçadas, que se associaram em 36,7% aos valores de conforto térmico calculado; as outras correlações encontradas foram 7,2% com a variável volume do espaço, 17,3% com área de parede externa de 0.20m de espessura, 15,5% com a implantação, usando análise não paramétrica, e 0,0% usando análise paramétrica. As correlações entre as variáveis arquitetônicas e a produtividade também apresentaram valores baixos, sendo 1,9% com a variável implantação, 5,7% com o volume do espaço, 21,9% com a variável porcentagem de janela envidraçada externa; a área de parede externa de 0.20m se associou em 48,3% aos valores de carga de trabalho relatado pelos pesquisados, sendo este valor estatisticamente significativo, mas empiricamente não lógico. Embora as correlações encontradas não sejam significativas, não sendo possível afirmar que as variáveis arquitetônicas de ambientes de escritório naturalmente ventilados sejam capazes de interferir nas variáveis de conforto térmico, a ponto de influenciar na produtividade dos trabalhadores, este trabalho apresenta como resultados que os valores de carga de trabalho tiveram maior variação quando os trabalhadores estavam sob leve desconforto por frio ou calor (+/-14, 50%), do que quando estavam em níveis de conforto entre -0,5>PMV<+0,5 (+/-8,50%). Isto mostra que o nível de conforto interfere na produtividade, porém não se sabe como e quanto. / The objective of this study was to find correlation between thermal comfort, productivity workers and architectural variables of naturally ventilated offices. The proposed issue was: what are the architectural variables of naturally ventilated office environments can interfere on of comfort's variables influencing worker productivity? The theoretical framework involved the topics: thermal comfort, architecture of the buildings, ergonomics and performance evaluation. The methodological approach used was cross-sectional study of an applied nature, quantitative, descriptive and exploratory making a causal analysis by a case study. In collecting data we used two instruments to measure thermal variables two subjective evaluations, one to measure the thermal comfort and the other to measure the subjective worker productivity, and samples physical dimensions of the built environment where each worker played their tasks. The sample consists of 4 companies, 10 architectural environments and 25 office workers conducted 45 reviews in different time periods. Statistical analysis involved the identification of outliers; normality and correlation between variables. As results, 2% of yield values can be explained by the thermal comfort levels calculated. The correlations between the architectural variables and the thermal comfort variable showed low correlations, and the one that was statistically significant was the percentage of glazed window that were associated in 36.7% to the calculated thermal comfort values, the other correlations were 7.2% with the variable volume of space, 17.3% with external wall area of 0.20 m thick, 15.5% with the implantation of space using non-parametric analysis and 0.0% using parametric analysis. The correlations between the architectural variables and productivity also showed low values, being 1.9% with the implantation of space variable, 5.7% with the volume of space, 21.9% with the variable percentage of external glazed window, the area outer wall of 0.20m was associated in 48.3% the workload values reported by respondents, and this was statistically significant but empirically not logical. Although the correlations are not significant, it is not possible to say that the architectural variables naturally ventilated office environments, researched, are able to interfere with the thermal comfort variables to interfere in worker productivity, this paper presents results as the workload values had higher variation when workers were under discomfort by cold or heat (+/-14. 50%) than when they were in comfort levels between -0.5> PMV <+0.5 (+ / -8.50%). This shows that the comfort level interferes with productivity, but it is unknown how and how much.
35

Desempenhos térmico, luminoso e energético de unidades de um conjunto habitacional implantado pelo programa de arrendamento residencial PAR, em Maceió AL

Almeida, José Eduardo Castro de 28 September 2006 (has links)
This study is an investigation of the thermal and lighting performance, and of the potential to the energy conservation of a residential set that was implanted by the program named Programa de Arrendamento Residencial PAR , in Maceió AL, by means of computer simulation using softwares Arquitrop and TropLux. The methodology was based on computer simulation. The thermal and luminous performance results were analyzed by comparing to standard values and were used as a base to the estimative of the energy consumption that was used to the obtaining of the comfort conditions. The statistical treatment of the results obtained from the simulations made possible the knowledge of the performance of models and their quantification. The study confirms the tendency of a sensation of thermal discomfort that final users suffer and show the trueness of their appeal regarding to the installation of devices to the support of thermal comfort (air conditioner, awning, windows films), being source of information to upcoming PAR projects. The evaluation of the lighting performance showed that it has enough light in points of study, to exam of the use of protectors that maintain the shade in apertures, so that, despite the reduction of available light, it could be possible to get reduction on the internal temperature. This study suggest in cases like the one above mentioned, in Maceió the disregard for the quality of projects, in what concerns the comfort and energy efficiency, transferring to the final user the posterior waste of money. We expect, therefore, to contribute to the improvement of the architectural design of the buildings that have their characteristics investigated, as well as to provide information to the designers regarding to the aspects approached in this study. / Este trabalho constitui-se de uma investigação do desempenho térmico e luminoso, e do potencial para conservação de energia, das unidades de um conjunto habitacional implantado pelo Programa de Arrendamento Residencial PAR, em Maceió AL, por meio de simulação computacional através dos programas Arquitrop e TropLux. A metodologia adotada utilizou-se das ferramentas de simulação de desempenho térmico e luminoso de edificações, cujos resultados foram analisados por meio de comparações com valores padrões e serviram como base para as estimativas de consumo de energia destinada à obtenção das condições de conforto. O tratamento estatístico dos resultados obtidos nas simulações possibilitou o conhecimento do desempenho dos modelos e sua quantificação. O estudo confirma a tendência de sensação de desconforto térmico manifestada pelos usuários e comprova a pertinência das solicitações destes quanto à instalação de dispositivos para a promoção de conforto térmico (aparelhos de ar condicionado, toldos, filmes protetores), constituindo-se em fonte de informação para futuros projetos do PAR. A avaliação do desempenho luminoso mostrou que há disponibilidade de luz suficiente nos pontos de estudo, para se examinar a utilização de protetores que promovam o sombreamento das aberturas, para que, apesar da redução da luz disponível, se obtenha redução na temperatura interna do ambiente. Este trabalho aponta no caso de empreendimentos dessa natureza, em Maceió para a falta de preocupação com a qualidade dos projetos, dos pontos de vista de conforto e eficiência energética, transferindo para o usuário o ônus econômico daí decorrente. Espera-se, assim, contribuir para o aprimoramento dos projetos de arquitetura, destinados a habitações com as características investigadas, bem como servir de informação para projetistas quanto aos aspectos abordados neste trabalho.
36

Conforto térmico em salas de aula localizados em clima quente e úmido : uma avaliação do limite inferior da zona de conforto. / Thermal comfort in classrooms placed in warn and umid climate: an evaluation of the lower limit of the comfort zone.

Araujo, Mara Rubia de Oliveira 16 July 2008 (has links)
The thermal comfort approach, is straightly linked to society s quality of life expectation, that it s based on researches made inside climatized chambers and it s related to the thermal balance between the men and the environment. Among these studies, much has been questioned about the use of data obtained and represented on nomograms, in locations with different climatic characteristics which the study was made for. Therein, from an thermal evaluation made inside classrooms in Maceió/AL, this work was proposed to investigate the lower limit of the comfort zone to the hot and humid climate. The results were analysed based on the existing and common comfort zones used in the country. The work begins with an overview of the theme, then is presented the methodology, which describes and shows the used procedures to obtain and analyse analyze the data. The conclusion of the study shows that the percentage of users satisfied with the thermal environment to which they were submitted, was about 60%, higher than the percentage of dissatisfied users through the entire period analysed. However, the comfort resultant polygon obtained by the colleted data, based on the lower limit of comfort, differs from some comfort zones existing, being its minimal temperature about 21ºC. The differences among existing tolerances to air temperature, moisture, air movement, etc, may be an indicative of the adaptation of people to the climate, which suggests, therefore, the necessity of specifying the different comfort zones to each location. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O estudo do conforto térmico, diretamente ligado à expectativa de qualidade de vida da sociedade, está baseado em pesquisas realizadas em câmaras climatizadas e relacionado ao balanço térmico entre o homem e o ambiente. Dentre esses estudos, muito tem sido questionado quanto à utilização dos dados obtidos e representados em nomogramas, em localidades com características climáticas diferente da qual o estudo foi direcionado. Neste sentido, a partir de uma avaliação realizada em ambientes de salas de aula em Maceió/AL, esse trabalho buscou investigar o limite inferior da zona de conforto para o clima quente e úmido. Os resultados obtidos foram analisados com base nas zonas de conforto existentes e utilizadas no país. O trabalho inicia-se com uma visão geral sobre o tema e segue com a apresentação da metodologia, na qual são descritos e apresentados os procedimentos utilizados para a coleta e análise de dados. A conclusão do estudo feito demonstrou que o percentual de usuários satisfeitos com o ambiente ao qual estavam submetidos, foi de aproximadamente 60%, maior que o percentual de insatisfeitos em praticamente todo o período analisado. No entanto, o polígono de conforto resultante dos dados coletados com base no limite inferior de conforto, difere de algumas zonas de conforto existentes, tendo sua temperatura mínima de 21°C. As diferenças existentes entre tolerâncias para temperatura, umidade, movimento do ar, etc, podem ser um indicativo da adaptação das pessoas ao clima, sugerindo, portanto, a necessidade de se especificar as zonas de conforto diferenciadas para cada região.
37

Arquitetura e clima na Bolivia : uma proposta de zoneamento bioclimatico / Architecture and climate in Bolivia : a project for bioclimatic zoning

Campos Navarro, Fidel Ernesto 31 August 2007 (has links)
Orientador: Mauricio Roriz / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-09T21:23:10Z (GMT). No. of bitstreams: 1 CamposNavarro_FidelErnesto_M.pdf: 24455849 bytes, checksum: 1545430cfcbfbeb60fea785ffb1f44fb (MD5) Previous issue date: 2007 / Resumo: O clima compreende um conjunto de variáveis climáticas, que dependendo do seu maior ou do menor grau de incidência é capaz de configurar e de caracterizar o bioclima de uma determinada região. Portanto, é imprescindível para a área da Construção e do Conforto que se tenha um conhecimento prévio do bioclima da região, com o propósito de conceber ambientes construídos confortáveis, por meio do aproveitamento das potencialidades energéticas naturais que são oferecidas pelo ambiente circundante à localização do projeto arquitetõnico. Por isso, o presente trabalho apresenta uma proposta de zoneamento bioclimático para a Bolívia, tendo como referência a análise das adequações construtivas utilizadas na arquitetura vernácula boliviana, em resposta ao clima das zonas. Este trabalho consistiu em duas etapas: a primeira - na coleta de dados medidos (normais climatológicas) sobre Temperaturas e de Umidades de 72 localidades bolivianas e 18 de países vizinhos, além de duas bases de dados interpolados: altitudes e normais climatológicas de todo o planeta. Para complementar espacialmente os dados climáticos, utilizou-se um processo de interpolação d,enominado Média Aritmética entre pontos vizinhos, o que permitiu produzir uma nova base de dados para o território boliviano. Posteriormente, esses dados foram novamente submetidos ao software ABC - Architectural Bioclimatic Classification o que finalmente resultou na definição de oito zonas bioclimáticas. Na segunda etapa - a partir da localização de alguns exemplos de arquitetura vernácula e da obtenção das normais climatológicas do seus respectivos locais, estes dados foram submetidos ao software ABC e às Planilhas de Mahoney Adaptada, com o objetivo de quantificar e qualificar as estratégias bioclimáticas necessárias, para fazer uma analogia dos parâmetros de correção a nível arquitetõnico utilizados pelos construtores nativos. Observou-se uma grande correlação entre as recomendações bioclimáticas das zonas determinadas e as respostas construtivas vernáculas. Portanto, o zoneamento bioclimático resultante pode orientar na escolha das estratégias bioclimáticas e, desta forma, contribuir com o desempenho térmico interno dos ambientes construídos / Abstract: Climate is a set of climatic variables which, depending on the force with which they act, can affect the bioclimate of a region. It is therefore necessary for the Building and Comfort area to know beforehand the climate of a region, so as to provide comfortable buildings by leveraging the natural energy potential of the environment around the architecture project. This work presents a bioclimaticzoning project for Bolivia, using as a reference the building adaptations made by Bolivian vernacular architecture in response to the zones' climates. This was divided into two steps: first, collecting data (climate normais) on temperature and humidity of 72 places in Boliviaand 18 places in neighbouring countries, along with two interpolated databases: altitude and climatic normais for the entire planeI. To complement spacially the climatic data, we used an interpolation process called Arithmetic Mean of Neighbouring Points, which allowed us to create a new database of the Bolivianterritory. Then these data were fed again to the ~BC (Architectural Bioclamatic Classification) software, which resulted in the defining of eight bioclimaticzones. In the second step, from the examples of vernacular architecture found and the climatic normals obtained from their sites, these data was fed to the ABC software and to the Adapted Mahoney Tables, in order to quantify and classify the necessary bioclimatic strategies so as to make an analogy with the architectural correction parameters used by the native constructors. We noticed a strong relation between bioclimatic recomendations of the determined zones and the vernacular building solutions. Therefore the resulting bioclimatic zoning can serve as a guide in choosing the bioclimatic strategies and contribute to the internal thermal performance of buildings / Mestrado / Edificações / Mestre em Engenharia Civil
38

Comportamento termico de coberturas de fibrocimento em Campinas, SP : aplicação de tecnicas passivas / Thermal behavior of fiber-cement roofing in Campinas -SP application of passive cooling

Teixeira, Carla Fernanda Barbosa, 1977- 28 July 2006 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-09T13:58:12Z (GMT). No. of bitstreams: 1 Teixeira_CarlaFernandaBarbosa_M.pdf: 5638005 bytes, checksum: 9a53dab8a270c161717fe41b2ab388d4 (MD5) Previous issue date: 2006 / Resumo: O Brasil possui a maior parte de suas terras em clima tropical. Sendo a cobertura o elemento construtivo mais exposto à radiação solar direta, toma-se um desafio aos pesquisadores e projetistas, atenuar as temperaturas nas coberturas das edificações e contribuir para o uso racional de energia. O objetivo desta pesquisa é monitorar o desempenho térmico de coberturas de fibrocimento em_ células-teste na cidade de Campinas, SP, com aplicação de técnicas passivas de resmamento. Utilizaram-se quatro células-teste: uma célula-teste de referência, e outras três com os sistemas: evaporativo, radiante e reflexivo, respectivamente, e monitoramento das temperaturas superficiais internas das telhas (TT' s) e temperaturas do ar dos áticos (T AA' s), no período de 21 de janeiro a 9 de fevereiro de 2006. Para o sistema de resmamento evaporativo foram utilizados ciclos de aspersão com diferentes intervalos no período todo. Entre as técnicas monitoradas, o melhor comportamento térmico foi verificado no 2° período (de 26 a 30/jan com aspersão contínua) na temperatura da superficie interna da telha do sistema evaporativo (TTevap = 23,2°C) apresentando um decréscimo de 1,3°C em relação a célulateste de referência e um acréscimo de 0,1 °C em relação as médias da temperatura do ar para o período. Nas médias da temperatura do ar dos áticos, o 2° período apresentou os menores valores para os sistemas: reflexivo (TAArefl =23,4°C) e evaporativo (TAAevap = 23,5°C), apresentando uma atenuação de 0,5°C e 0,4°C em relação a célula de referência respectivamente, além de uma elevação de 0,3°C em relação as médias da temperatura do ar externo. Os resultados, analisados através de tratamento estatístico, demonstram a viabilidade do uso do sistema evaporativo em condições climáticas de elevada umidade relativa do ar, contribuindo para atenuar os efeitos das hostilidades climáticas em coberturas das edificações / Abstract: In Brazil, the tropical climate is predominant in most of regions. Roofing is the building component with the highest exposition to direct solar radiation. The challenge for researchers and designers is to achieve cornfort in the built environrnent and to contribute to energy saving, proposing roofing systems with good thermal insulation, and consequently lesser internal surface temperatures. The objective of this research is to monitor the thermal behavior of fiber-cement roofing and to present a discussion about the results obtained in cell-tests in the city of Campinas, SP, through passive cooling techniques. Four cell-tests were used: one cell-test was adopted as reference, and the other three were analyzed with evaporative, radiative and reflective systems, respectively. The evaporative system was tested with different aspersion cycles through spraying systems and intervals. The monitored parameters were the internal surface temperatures of the roofing tiles (TT s) and attic air temperatures (TAA's) in the period of January 21st to February 9th of2006. Among the monitored passive techniques, the best thermal behavior was observed in the 2nd period (iTom January 26th to 30th, corresponding to continue spraying), related to the internal surface temperature with the evaporative system (TTevap = 23,2°C). A reduction of 1,3°C was observed, as compared to the reference test-cell and and an increase of 0,1 °C in comparison with the average air temperature. In relation to the average of attic air temperature, the 2nd period presented the lowest temperature for reflexive system (T AArefl = 23,4°C) and evaporative system (TAAevap = 23,5°C); a reduction of 0,5°C and 0,4°C in relation of the reference test-cell respectively was observed; also, it showed an increase of 0,3°C as compared with air temperature. The results presented through statistical analyses demonstrated that the use of the evaporative system in climatic conditions with high relative humidity is viable, contributing, therefore, to attenuate the effects of climatic hostilities in the roofing buildings / Mestrado / Edificações / Mestre em Engenharia Civil
39

Estudo da ventilação natural em edificações com captadores de vento multidirecionais por meio de ensaios em túnel de vento e simulações computacionais / Study of natural ventilation in buildings with multidirectional wind catchers through wind tunnel testing and computer simulations

Andrade, Nixon Cesar de, 1976- 24 August 2018 (has links)
Orientador: Lucila Chebel Labaki / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-24T13:55:02Z (GMT). No. of bitstreams: 1 Andrade_NixonCesarde_D.pdf: 32217441 bytes, checksum: 25e8b1672ea93f3aae90a2513264ae3e (MD5) Previous issue date: 2013 / Resumo: A ventilação natural é uma das estratégias mais adequadas para o resfriamento passivo dos edifícios e para a manutenção da qualidade do ar. Uma das alternativas existentes para se alcançar tal proposição é a utilização de torres de vento situadas acima do nível da cobertura, as quais podem funcionar como captadores ou extratores de ar. Esta pesquisa tem como objetivo geral avaliar quatro tipos de torres, atuando como captadores: a unidirecional, com uma abertura para a entrada de vento, em locais onde o vento se movimenta predominantemente em uma direção; a tetradirecional, com quatro aberturas; a octodirecional, com oito aberturas e a dodecadirecional, com doze aberturas; em locais em que o vento age em várias direções. Para alcançar o objetivo utilizaram-se ensaios em túnel de vento e simulações no software CFX®, os quais permitiram estudar as características técnicas das torres analisadas e seus efeitos sobre a ventilação interna do ambiente, bem como contribuir para a difusão desse sistema de ventilação no Brasil. O desenvolvimento do trabalho foi dividido nas seguintes etapas: definição das geometrias das torres; definição, construção e instrumentação das maquetes; definição dos ângulos de incidência do vento; ensaios no túnel de vento e simulações no software CFX®: velocidade e pressão. Os resultados obtidos a partir de uma série de experimentos e simulações computacionais permitiram a análise e comparação dos diversos projetos propostos, auxiliando, portanto, na determinação das configurações mais adequadas, além da verificação da compatibilidade entre os dois tipos de estudo, concluindo que as torres octodirecional e dodecadirecional são as mais eficientes, pois proporcionam maiores valores de velocidade do ar interno na maioria das posições consideradas. Desta forma, utilizando o túnel de vento e o CFX®, as análises possibilitaram desenvolver melhorias para os ambientes avaliados, no que se refere ao desempenho da ventilação. Isso proporcionará melhores taxas de conforto aos usuários da edificação, considerando todas as aberturas para permitir o fluxo do vento em qualquer situação. Ademais, podem-se verificar as distribuições das aberturas de entrada e saída mais adequadas para captação e distribuição do vento no interior dos ambientes, proporcionando melhores condições de conforto térmico / Abstract: Natural ventilation is one of the most appropriate strategies for passive cooling of buildings and the maintenance of air quality. One of the alternatives for achieving such proposal is the use of wind towers above the level of the roof, which can function as air catchers or extractors. This research aims to evaluate four types of towers, acting as air catchers: unidirectional, with an opening for the entrance of the wind, in locations where the wind moves predominantly in one direction, the tetradirectional, with four openings, the octodirectional, with eight openings and dodecadirectional, with twelve openings, in locations where the wind moves in various directions. To achieve the goal, tests in wind tunnel and simulations in CFX® software were performed, which allowed the study of the technical characteristics of the analyzed towers and their effects on the indoors ventilation, as well as the contribution to the spread of this ventilation system in Brazil. The methodology was divided into the following steps: the definition of the geometry of the towers; definition, construction and instrumentation of the models; definition of the angles of the incidence of the wind; wind tunnel tests and simulations in CFX® software: speed and pressure. The obtained results from a series of experimental and computational simulations allowed the analysis and comparison of the various proposed design configurations, helping, therefore, in determining the most appropriate settings, besides the verification of compatibility between the two types of study, concluding that the octodirectional and dodecadirectional towers are the most efficient ones , as they provide higher rate of indoor air speed in most considered positions. Thus, using the wind tunnel and CFX®, the analysis allowed the development of enhancements to the analyzed environments, concerning the performance of the ventilation. This will provide better comfort rates to the users of the building, considering all openings to allow the wind flow in any situation. Furthermore, the most suitable distribution of inlet and outlet openings for the catchment and distribution of the wind within the environments may be verified, providing better conditions of thermal comfort / Doutorado / Arquitetura e Construção / Doutor em Engenharia Civil
40

Impacto da morfologia no desempenho térmico das parcelas urbanas em clima equatorial na cidade de Belém

PINHEIRO, Dorival Freitas 11 April 2013 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-05-26T11:26:47Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ImpactoMorfologiaDesempenho.pdf: 6847855 bytes, checksum: 5b8cad37e4eb573f9fafd352ee64975f (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-06-02T13:32:04Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ImpactoMorfologiaDesempenho.pdf: 6847855 bytes, checksum: 5b8cad37e4eb573f9fafd352ee64975f (MD5) / Made available in DSpace on 2017-06-02T13:32:04Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ImpactoMorfologiaDesempenho.pdf: 6847855 bytes, checksum: 5b8cad37e4eb573f9fafd352ee64975f (MD5) Previous issue date: 2013-04-11 / O objetivo deste estudo é analisar o impacto gerado pelo contexto morfológico de parcelas urbanas, segundo suas características próprias a partir das variáveis presentes no microclima urbano inerentes aos Bairros da Cidade Velha e Umarizal em Belém. Demonstrar, a partir do padrão metodológico desenvolvido, uma aproximação dos efeitos das trocas térmicas dentro das parcelas urbanas com suas diferentes tipologias encontradas, o que permitirá, além do entendimento mais aproximado dos fenômenos resultantes da interação climática com as tipologias específicas, evidenciar estratégias urbanísticas mais apropriadas ao desempenho térmico. Para demonstrar os efeitos destes parâmetros urbanísticos e sua influência na qualidade do microclima foram utilizados como estratégias de aquisição de dados, captação de imagens IFR (infravermelho) de superfícies, fotos com lente angular olho de peixe, registro de temperaturas de globo, bulbo seco e úmido, sol ar, levantamento de campo das edificações, somadas às técnicas de análise do balanço energético Fator de Visão de Céu, Massa Construída e Recorte de Carga Térmica. O Bairro da Cidade Velha está inserido na origem da formação urbana da cidade e, dentro do seu contexto morfológico, possui características volumétricas que, ao seu tempo, foram apontadas como soluções de adaptação ao clima, tornando-o propício ao desenvolvimento de estudos térmicos. Já o bairro do Umarizal, que faz parte da área de expansão central da cidade, possui como característica morfológica marcante um processo de crescente verticalização, principalmente na última década, e com isso, vem se constituindo no bairro com maior mudança de perfil construtivo e de adensamento dos últimos anos, o que o define como peça fundamental para esta investigação. Tendo como base alguns estudos já realizados e procurando agregar novos parâmetros de análise e conceitos, definiu-se a utilização de técnicas de análise do balanço energético e das trocas térmicas urbanas capazes de identificar, conceitualmente, a capacidade de acúmulo de carga térmica e indicar caminhos para implementar procedimentos de análise de desempenho térmico de frações urbanas. Critérios metodológicos desenvolvidos a partir da investigação dos efeitos provenientes da relação entre padrões climatológicos locais e padrões urbanísticos de ocupação podem se bem aproveitados, gerar parâmetros urbanísticos de ocupação que viabilizem as cidades não só em suas questões ambientais como na sua eficiência global, apontando soluções aos planejadores e gestores urbanos ao instrumentalizar um registro da capacidade de “carga” destes determinados territórios. / The objective of this study is to analyze the impact generated by models of occupation of urban spaces in installments, according to its own characteristics of the variables present in the urban microclimate inherent Neighborhoods Old Town and Umarizal Demonstrate in Belém, from the standard methodology developed, an approximation of the effects of thermal exchanges within the urban portions with their different typologies found, which will allow, besides understanding more approximate of the resulting phenomena of the climatic interaction with the specific typologies, to evidence more appropriate town planning strategies to thermal performance. To demonstrate the effects of these urban parameters and their influence on the quality of the microclimate, were used as strategies for data acquisition, image capture IFR (IR) surface, angled shots with a fisheye lens, record temperatures globe, dry and humid bulb, sun air, field survey of the buildings, together with the technical analysis of energy balance factor Sky View, Built Mass and Cut Heat Load. The Old Town district is inserted in origin of formation of the town and within its context morphological Volumetric has characteristics that in his time been regarded as solutions to climate adaptation, making it conducive to the development of thermal studies. Already Umarizal neighborhood, which is part of the expansion area of the city center, has a characteristic morphological marked a process of increasing vertical integration, especially in the last decade, and with it, has been constituted in the district with the highest profile change and constructive densification of recent years, which defines it as a key to this investigation. Based on some previous studies and looking to add new analysis parameters and concepts, we defined the use of techniques for analyzing of the energy balance and the thermal exchanges urban able to identify, conceptually, the ability to build thermal load and indicate ways implement procedures for analysis of thermal performance of urban fractions. Methodological criteria developed from the investigation of the effects arising from the relationship between local climatological patterns and urban standards of occupancy can be good use, generate urban parameters that enable the occupation of cities not only in their environmental issues in its overall efficiency, pointing to solutions to planners and urban managers to equip a record of the capacity to "load" these determined territories.

Page generated in 0.1884 seconds