• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 8
  • 1
  • Tagged with
  • 53
  • 36
  • 26
  • 23
  • 18
  • 15
  • 12
  • 12
  • 12
  • 11
  • 11
  • 11
  • 11
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avaliação do desempenho da ventilação natural e do sombreamento em casas de Maceió projetadas segundo princípios abordados na cartilha de Armando de holanda / Perfomance evaluation of natural ventilation and shading of houses in Maceió designed according to principles discussed in the Armando de Holanda s booklet

Castro, Renata Torres Sarmento de 25 November 2011 (has links)
This survey deals with the dimensionality of the natural ventilation and its fitness to building houses in the Brazilian Northeast. It is a case study due to the limited sample of the object evaluated, since that its abridgement involved only two houses located in Maceió city in the state of Alagoas. As matter of fact, by the end of 1970 through 1980, a pernambucano architect under the name of Armando de Holanda wrote a booklet guide containing 9 (nine) bioclimatic strategies to solve the problem of the hot and damp ventilation that reaches the tropical regions causing distress to their inhabitants, above all inside the houses. According to Holanda s point of view the trouble could be lessened if the building of the houses were more adequate and suitable to the local temperature of the environment. The statements lined out by Holanda consisted of nine (9) strategic. In the inquiry made up, some of Holanda s a priori strategic propositions have been selected and evaluated such the natural air performance, the shading and other items of two houses built by two architects who drew and carried out an experimental project for their own dwellings. Both houses were object of analysis and evaluation by means of a detailed methodoly concerning the climatic data and the bioclimatic strategies followed by an essay of ventilation and sunny rays with virtual models through computerized SketchUp application of the solar chart. As a result, the house 1 (one) showed up efficient average of natural ventilation and shading, while the house 2 (two) attested the average and positive performance of natural ventilation as well as shading. Yet in both houses the direct observation registered adequate bioclimatic strategies, but some determined solutions seemed inadequate to a hot and damp climate as inward divisions no evidence of eaves. Hypothetically the conclusion is that Holanda s guidance may cause good effect when well fitted, in spite of being necessary some practical experiments to assure thermal comfort to the buildings situated in hot and damp regions, with the adoption of the suggested methodoly and good tools of evaluation preceded by an architectonic planning. / Fundação de Amparo a Pesquisa do Estado de Alagoas / A tradição construtiva luso-brasileira, como ilustram as tradicionais casas de fazenda, e o modernismo dos anos de 1950-1970, como as casas modernistas urbanas, adotavam a preocupação com a ventilação natural e a proteção solar no trópico quente e úmido. Na década de 1970, o arquiteto pernambucano Armando de Holanda desenvolveu o Roteiro para Construir no Nordeste, reunindo nove estratégias bioclimáticas. Para o clima quente e úmido do Nordeste brasileiro, com temperaturas amenas durante quase todo o ano, as principais estratégias de projeto para promover conforto térmico resumem-se em permitir o escoamento da ventilação natural no interior das edificações e promover o sombreamento das fachadas e aberturas. Contudo, com o intensivo desenvolvimento dos conhecimentos em conforto ambiental no Brasil, estima-se que a adoção exclusiva dessas estratégias, sem experimentos práticos, não é suficiente para garantir a eficiência da edificação, necessitando, portanto, da adoção conjunta de métodos de avaliação de desempenho ambiental. O objetivo dessa pesquisa de mestrado em arquitetura e urbanismo é avaliar o desempenho da ventilação natural e do sombreamento de casas projetadas segundo os princípios abordados na cartilha de Armando de Holanda. Avaliaram-se duas casas construídas em Maceió/AL, entre final de 1970 e início de 1980, projetadas por arquitetos e professores da Universidade Federal de Alagoas. A metodologia proposta compreendeu: detalhamento de dados climáticos e estratégias bioclimáticas para Maceió; visitas às residências, levantamentos arquitetônicos, análise bioclimática; entrevistas com os arquitetos/moradores das casas; realização de ensaios de ventilação, no equipamento mesa d´água com maquetes vazadas, e de insolação com modelos virtuais, no programa de computador SketchUp e aplicação da carta solar. Constatouse médio desempenho de ventilação natural e de sombreamento na Casa 1; e médio e positivo desempenho de ventilação natural e de sombreamento, respectivamente, na Casa 2. Verificouse a utilização de adequadas estratégias bioclimáticas nas casas, porém destacaram-se determinadas soluções inadequadas para o clima quente e úmido, como a compartimentação interna e a ausência de beirais. Conclui-se pelos adequados princípios bioclimáticos do Roteiro, porém pela necessidade de experimentos práticos para garantir conforto térmico às edificações de forma a prever as deficiências e solucioná-las. Sugere-se a aplicação da metodologia proposta e das ferramentas de avaliação em pesquisas e planejamento arquitetônico para possibilitar maior garantia de desempenho térmico nas edificações, localizadas em regiões de clima quente e úmido.
42

APLICAÇÃO DO RTQ-R NA AVALIAÇÃO DA EFICIÊNCIA ENERGÉTICA DE EDIFICAÇÕES MULTIFAMILIARES DE INTERESSE SOCIAL PARA AS ZONAS BIOCLIMÁTICAS BRASILEIRAS / APPLICATION OF THE RTQ-R IN ENERGY EFFICIENCY EVALUATION OF MULTI-FAMILY SOCIAL HOUSING BUILDINGS TO THE BRAZILIAN BIOCLIMATIC ZONES

Fagundes, Renata Magalhães 18 March 2014 (has links)
Different methods of managing the housing topic in Brazil were applied over time however the housing deficit still persists and in the name of economy the same project is used in any climatic situation without worring with building aspects of thermal confort and energy efficiency. The aim of this work is to evaluate and propose changes to improve the energy efficiency levels obtained by a multi-family social housing building considering its location in the different Brazilian bioclimatic zones. For this it was used the prescriptive evaluation method of the Technical Regulations for Energy Efficiency Labelling of Residential Buildings (RTQ -R). The studied building was evaluated and obtained low efficiency levels ranging between D and E in all bioclimatic zones mainly because some prerequisites were not achieved and because of the low energy efficiency of the water heating system. The building had its efficiency level considerably improved with simple changes in the windows allied to the proposition of an efficient water heating system and the search for obtaining bonus indicating that the evaluation patterns established by RTQ -R may not be rigorous enough to produce significant changes in currently developed projects causing real improvements in energy efficiency in residential buildings of the type studied in this work. Were extremely important to the results obtained by the envelope of apartments the contact of its floor with the soil the roof and solar orientation of windows and external walls. / Diferentes formas de abordagem da questão habitacional no Brasil foram empregadas ao longo do tempo, entretanto o déficit habitacional ainda persiste, e, em nome da economia, usa-se o mesmo projeto em qualquer situação climática, sem preocupação com as questões de conforto térmico e eficiência energética da edificação. Este trabalho teve como enfoque avaliar e propor alterações para melhoria dos níveis de eficiência energética obtidos por uma edificação multifamiliar de interesse social, considerando sua implantação nas diferentes zonas bioclimáticas brasileiras. Para isso, foi empregado o método prescritivo de avaliação do Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edifícios Residenciais (RTQ-R). A edificação objeto de estudo foi avaliada e obteve níveis de eficiência baixos, variando entre D e E, em todas as zonas bioclimáticas, principalmente devido ao não cumprimento de alguns pré-requisitos e à baixa eficiência energética do sistema de aquecimento de água. A edificação teve seu nível de eficiência melhorado consideravelmente com alterações simples nas aberturas, aliadas à proposição de um sistema de aquecimento de água eficiente e à busca da obtenção de bonificações, indicativo de que os parâmetros de avaliação estabelecidos pelo RTQ-R podem não ser rigorosos o suficiente para desencadear mudanças significativas nos projetos desenvolvidos atualmente, que causem real melhoria da eficiência energética em edificações residenciais do padrão estudado nesse trabalho. Foram de extrema relevância nos resultados obtidos pela envoltória das UHs o contato do piso das mesmas com o solo, a cobertura e a orientação solar de aberturas e paredes externas.
43

Refrigeração evaporativa por aspersão em telhas de fibrocimento: estudo teórico e experimental

Roriz, Victor Figueiredo 01 August 2007 (has links)
Made available in DSpace on 2016-06-02T20:09:08Z (GMT). No. of bitstreams: 1 1646.pdf: 3878244 bytes, checksum: 1b913364f7458c2e95fc16bda01f835e (MD5) Previous issue date: 2007-08-01 / Financiadora de Estudos e Projetos / This research focuses the evaporative cooling by water aspersion on wavy cement fiber tiles in the city of São Carlos, SP, seeking to use it to reduce the buildings heat gains. A theoretical model was developed, based on classic equations of fluids mechanic, applied to iterative calculations of heat flows on the tile superior surface, considered as control surface. In the work development, this model was progressively adjusted to experimental data obtained in a test cell, exposed to the local climatic conditions, with the monitoring of superficial temperatures of both faces in two tiles, one maintained dry and other under intermittent aspersion of water. The research results indicated that, despite of still being susceptible to improvement, the theoretical model already presents quite satisfactory approach with the measured data. Applying a statistical adjustment to the proposed model of iterative heat flows calculation, it was obtained a correlation coefficient between measured and estimated temperatures of 0,999 and a standard deviation of 0,35 ºC. During the experiments, the average evaporative heat flow was 409 W/m2. Theaverage water volume evaporated was 0,7 l/(m².h), corresponding to an average difference of temperatures among the compared tiles of 5,12 K, for the daylight period. Due to the growing need of energy consumption reduction, this procedure seems to be a good option to reduce buildings thermal load, if compared to conventional air conditioning systems / Esta pesquisa enfoca a refrigeração evaporativa por aspersão de água sobre telhas onduladas de fibrocimento, na cidade de São Carlos, SP, visando sua utilização para redução dos ganhos de calor em edificações. Um modelo teórico foi desenvolvido, baseado em equações clássicas da mecânica dos fluidos, aplicadas em cálculos iterativos dos fluxos de calor sobre a superfície superior da telha, considerada como superfície de controle. No desenvolvimento do trabalho, este modelo foi progressivamente ajustado a dados experimentais obtidos em uma célula de teste, exposta às condições climáticas locais, sendo monitoradas temperaturas superficiais de ambas as faces em duas telhas, uma mantida seca e outra sob aspersão intermitente de água. Os resultados da pesquisa indicaram que, apesar de ainda ser passível de aprimoramento, o modelo teórico já apresenta aproximação bastante satisfatória com os dados medidos. Aplicando-se um ajuste estatístico ao modelo proposto de cálculo iterativo dos fluxos de calor, obteve-se um coeficiente de correlação entre temperaturas medidas e estimadas de 0,999 e um desvio padrão de 0,35 ºC. Durante os experimentos, o fluxo médio de calor por evaporação foi de 409 W/m2. O volume médio de água evaporado foi de 0,7 l/(m².h), correspondendo a uma diferença média de temperaturas entre as telhas comparadas, para o período diurno, de 5,12 K. Frente à crescente necessidade de redução de consumo de energia, esta parece uma boa opção para redução da carga térmica dos edifícios, se comparada aos sistemas convencionais de condicionamento de ar
44

DESEMPENHO TÉRMICO EM EDIFÍCIOS DE ESCRITÓRIO NA REGIÃO CENTRAL DO RIO GRANDE DO SUL / THERMAL PERFORMANCE IN OFFICE BUILDINGS IN THE CENTRAL REGION OF RIO GRANDE DO SUL

Ferreira, Francéli 19 January 2007 (has links)
This study seeks to detect the thermal performance in Office buildings as they add to a significant quantity of energy consumption in this country. Researches have revealed that 40 % of the final electricity consumption in office buildings is linked to the climate conditioning systems. Within this context there is no existence of projecting rules which establish minimum standards of thermal-electric performance in comparison to regional climatic conditions, considering the thermal variation experienced throughout the year. Thus, the present study aims to diagnose and compare the current condition of thermal performance in different types of office buildings located in six towns belonging to the central region of Rio Grande do Sul, which are included in bioclimatic zone two of Brasil. For such analysis a list of existing office buildings with at least five floors was made, in the towns of Cruz Alta, Ijuí, Lajeado, Santa Cruz do Sul, Santa Maria and Venâncio Aires. A sample of 36 buildings was selected. Following, the architecture designs and the construction information were analyzed, the buildings were sorted in five categories, according to criteria of floors number, width/depth relation of building and opaque/transparent closing area relation. For each category a representative building was selected, to which a better detail process of the construction system was made as well as internal and external temperature data for a period of thirteen days in summer and winter were recorded. The thermal performance of the buildings was assessed according to their capacity of absorption of the external thermal wave, related to its thermal inertia, opening areas and use standards of internal rooms. There was a great influence of solar radiation on the results, increased mainly by the influence on the thermal behavior of the orientation buildings of the monitored rooms, the opening area, the kind of glass and the color of opaque closings. It was noticed the necessity, for the climate of the studied region, of solar radiation control systems, so that the project decisions for the benefit of thermal conditions in summer do not cause loss in wintertime or vice-versa. / Este trabalho visa ao diagnóstico do desempenho térmico de edifícios de escritório, pois estes contribuem com uma parcela significativa do consumo de energia do país. Pesquisas revelam que 40 % do consumo final de energia elétrica em edifícios de escritórios estão ligados aos sistemas de condicionamento climático. Dentro deste contexto observa-se ainda a inexistência de diretrizes projetivas que estabeleçam padrões mínimos de desempenho termo-energéticas frente às condições climáticas regionais, sobretudo pela amplitude térmica verificada ao longo do ano. Assim, o presente trabalho objetiva diagnosticar e comparar a situação atual de desempenho térmico de diferentes tipologias de edifícios de escritório localizados em seis cidades pertencentes à região central do Rio Grande do Sul, estando às mesmas inseridas na zona bioclimática dois do Brasil. Para tal análise foi realizado um levantamento dos edifícios de escritório existentes, com no mínimo cinco pavimentos, nas cidades de Cruz Alta, Ijuí, Lajeado, Santa Cruz do Sul, Santa Maria e Venâncio Aires. Foram selecionados uma amostra de 36 edifícios. Em seguida foram analisados os projetos arquitetônicos e os dados construtivos, sendo os prédios agrupados em cinco tipologias, de acordo com os critérios de número de pavimentos, relação largura/profundidade do prédio e relação área dos fechamentos transparentes/opacos. Para cada tipologia foi selecionado um prédio representativo, para o qual foi feito um maior detalhamento do sistema construtivo e registrados dados de temperatura interna e externa durante um período de treze dias no inverno e verão. Foi avaliado o desempenho térmico dos edifícios de acordo com a sua capacidade de amortecimento da onda térmica externa, associada à sua inércia térmica, área de aberturas e padrão de uso dos espaços internos. Observou-se a grande influência da radiação solar nos resultados obtidos, evidenciada principalmente pela influência no comportamento térmico dos edifícios da orientação das salas monitoradas, da área de aberturas, do tipo de vidro e da cor dos fechamentos opacos. Foi observada a necessidade, para o clima da região estudada, da existência de dispositivos de controle da radiação solar, para que decisões de projeto que beneficiem as condições térmicas no período de verão não resultem em prejuízo no período de inverno, ou vice-versa.
45

ANÁLISE DO DESEMPENHO TÉRMICO E DA EFICIÊNCIA ENERGÉTICA DE UM EDIFÍCIO MULTIFAMILIAR EM ALVENARIA ESTRUTURAL NA ZONA BIOCLIMÁTICA 2 / ANÁLISE DO DESEMPENHO TÉRMICO E DA EFICIÊNCIA ENERGÉTICA DE UM EDIFÍCIO MULTIFAMILIAR EM ALVENARIA ESTRUTURAL NA ZONA BIOCLIMÁTICA 2

Moroni, Anne Lyse 28 August 2015 (has links)
A good building is one that has good thermal performance and energy efficiency, which is linked to the conditions of the local climate and projective strategies. This work is based on the analysis of thermal performance and energy efficiency of a multifamiliar building in structural masonry with concrete blocks and an average standard in the bioclimatic area 2. The multifamiliar building to be studied was defined by a survey of buildings in structural masonry concrete blocks, of average standard, located in the city of Santa Maria and with four apartments per floor. The evaluation of the thermal performance of the building was carried out by simplified method and simulation of NBR 15575: 2013, and energy efficiency was evaluated by the prescriptive method and simulation of the RTQ-R. The simulations were performed with the DesignBuilder program. The influence of the variables of thermal properties of opaque vertical locks in thermal performance was also analyzed. The multifamiliar building did not reach the criteria for simplified thermal performance of the standard, but ranked by simulation method with superior performance in winter and minimum in summer. Energy efficiency is obtained by the prescriptive method Level B and Level A by the simulation method. In the analysis of the influence of thermal variable properties, it was observed that the thermal performance in winter period reaches the NBR 15.575:2013 criteria, with a large variation of the minimum internal temperature and external temperature. During the summer the building also reaches the criteria for thermal performance, but with a slight variation of maximum temperature and the external temperature, emphasizing the necessity of preparing projects with careful accordance with the bioclimatic strategies. / Uma boa edificação é aquela que tem um bom desempenho térmico e uma boa eficiência energética, que esteja vinculado às condições do clima local e das estratégias projetuais. Este trabalho tem como fundamento a análise do desempenho térmico e da eficiência energética de uma edificação multifamilar em alvenaria estrutural com bloco de concreto de padrão médio na Zona Bioclimática 2. A edificação multifamiliar estudada foi definida através de um levantamento em edificações em alvenaria estrutural com bloco de concreto, de padrão médio, localizadas na cidade de Santa Maria e com quatro apartamentos por pavimento. A avaliação do desempenho térmico da edificação foi realizada pelo método simplificado e de simulação da NBR 15.575:2013 e a eficiência energética foi avaliada pelo método prescritivo e de simulação do RTQ-R. As simulações foram realizadas com o programa DesignBuilder. Também foi analisada a influência das variáveis das propriedades térmicas de fechamentos opacos verticais no desempenho térmico. A edificação multifamiliar não atingiu ao critério de desempenho térmico simplificado da norma, porém classificou-se pelo método de simulação com desempenho superior no inverno e mínimo no verão, e na eficiência energética obteve Nível B pelo método prescritivo e Nível A pelo método de simulação. Na análise da influência das variáveis térmicas, observou-se que o desempenho térmico, no período de inverno, atinge os critérios da NBR 15.575:2013, com uma grande variação da temperatura interna mínima em relação à temperatura externa máxima e, no período de verão, a edificação também atinge o critério de desempenho térmico, porém com uma variação pequena de temperatura máxima em relação à temperatura externa, enfatizando a necessidade de se ter cuidado na elaboração de projetos, de acordo com as estratégias bioclimáticas.
46

Ecolodge en el desierto de Paracas

Vidal Pimentel, Marisol 13 April 2019 (has links)
El presente proyecto responde a la necesidad de mantener, conservar y sostener en el tiempo, uno de los destinos naturales de nuestro país, como son las dunas del Desierto de Paracas, cuyo valor se trata de potenciar al crear un Ecolodge con énfasis en la Arquitectura Bioclimática. Paracas, a pesar de ser uno de los destinos preferidos por los turistas nacionales y extranjeros, no cuenta con una capacidad hotelera que pueda satisfacer los nuevos requerimientos en cuanto a hoteles con principios ecológicos. En tal sentido, se plantea un Ecolodge, donde el diseño y elementos constructivos a utilizarse estarán básicamente en función del clima de Paracas que se muestra soleado durante todo el año y acompañado de fuertes vientos. Esta nueva modalidad de hospedaje, se sustenta en principios de conservación y protección del medio ambiente, así como en el mejor aprovechamiento de la energía solar cuyos pilares son la captación, acumulación y distribución eficiente de la energía generada. Se toma en cuenta también el manejo de residuos, y el consumo responsable del agua con la finalidad de poderla reutilizar a través del sistema de riego por goteo, y generando además programas que beneficien directamente al desarrollo de la localidad y sus comunidades. / The purpose of this project is to maintain, preserve, and sustain throughout time, one of the main ecotourism destinations in our country, such as the Paracas Desert dunes. We aim to increase the value of this location through the development of an Ecolodge, with a focus on Bioclimatic Architecture. Given that Paracas is one of the preferred destinations by both foreign and local tourists, its main issue revolves around the lack of hotels that can satisfy new requirements in terms of ecological principles. In this context, raices the idea of an Ecolodge, where the design and building materials used will be selected in accordance with the Paracas climate, which is comprised of year-long sunshine accompanied by strong winds. The new hospitality approach is based upon conservation and environmental protection principles, as well as an improved use of solar energy, whose pillars include the collection, accumulation, and efficient distribution of energy. Waste management and responsible consumption of water is taken into account as well, with the purpose of re-utilizing water via a drip irrigation system. Finally, the strategy will ultimately generate programs that will directly benefit the development of local communities. / Tesis
47

Adaptabilidade e características nutricionais de Caprinos Anglo Nubiano em diferentes temperaturas. / Nutritional characteristics and adaptability of Goats Anglo Nubian in diferent temperatures.

ARAUJO, Tiago Gonçalves Pereira. 31 August 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-08-31T17:44:45Z No. of bitstreams: 1 TIAGO GONÇALVES PEREIRA ARAÚJO - TESE PPGEA 2013..pdf: 677256 bytes, checksum: 6f4318418a6df363bbc549759d4283ba (MD5) / Made available in DSpace on 2018-08-31T17:44:45Z (GMT). No. of bitstreams: 1 TIAGO GONÇALVES PEREIRA ARAÚJO - TESE PPGEA 2013..pdf: 677256 bytes, checksum: 6f4318418a6df363bbc549759d4283ba (MD5) Previous issue date: 2013-10 / CNPq / Capes / O objetivo deste trabalho foi de determinar a adaptabilidade e características nutricionais de caprinos Anglo Nubiano em diferentes temperaturas. O trabalho foi desenvolvido, em uma câmara bioclimática, utilizando-se seis caprinos machos e castrados, que foram submetidos a quatro condições climáticas, 20oC - temperatura de limite inferior da Zona de Conforto Térmico (ZCT); 24oC - dentro da ZCT; 28oC - dentro da ZCT e 32oC - acima da ZCT, com umidade relativa (UR) fixa em 60%. Foram coletados os dados referentes à temperatura do ar (TA), UR, temperatura do ponto de orvalho (TPO) e a temperatura de globo negro (TGN) para a determinação do ITGU, além de parâmetros fisiológicos como a frequência respiratória (FR), frequência cardíaca (FC), temperatura retal (TR) e temperatura superficial (TS) para determinação de teste de tolerância ao calor como o de Ibéria ou Rhoad e testes adaptabilidade como o de Benezra (CA1 e CA2), a determinação dos gradientes térmicos foi feito através da diferença entre as temperaturas retal e superficial (TR-TS) e entre as temperaturas superficial e ambiente (TS-TA) como parâmetro de adaptabilidade. Para a avaliação do comportamento ingestivo foi utilizado a técnica da varredura instantânea a cada cinco minutos. Para o consumo de nutrientes e digestibilidade os animais foram mantidos em gaiolas para ensaio de metabolismo durante todo o período experimental fazendo a coleta total de fezes, ração e sobras de ração. O delineamento experimental foi o inteiramente casualizado, com quatro tratamentos (temperatura), seis repetições (animais). Os dados foram avaliados por meio de análise de variância e, quando significativos, foram comparados pelo teste Tukey a 5% de probabilidade, para a determinação do consumo de nutrientes foi feito análise de regressão. Os resultados de ITGU indicaram que as temperaturas 20 e 24°C conferiram condições climáticas adequadas a raça. Houve diferença estatística com a elevação da temperatura para a TS, FC e FR, sendo que a TR manteve-se constante e dentro da normalidade. Para os parâmetros fisiológicos e gradientes de temperatura, houve efeito de temperatura (P<0,05) com o aumento da temperatura no interior da câmara, assim como os registros para o teste de Ibéria e CA1 e CA2, havendo alteração com aumento da temperatura no interior da câmara. No comportamento ingestivo houve uma maior procura por água com o aumento da temperatura e houve uma diminuição na ingestão de alimentos, porém não houve diferenças para o consumo de nutrientes (CEE, CPB e CFDN). Assim podemos afirmar que caprinos da raça Anglo Nubiano demostraram-se altamente adaptados as condições estudadas. / The objective of this study was to determine the adaptability and nutritional characteristics of Anglo Nubian goats at different temperatures. The work was developed in a climate chamber using six males and castrated, who underwent four climatic conditions, 20oC - temperature lower limit of Thermal Comfort Zone (TCZ); 24oC - within the TCZ; 28oC - within the TCZ and 32oC - above the TCZ, with fixed relative humidity (RH) of 60%. Data relating to air (AT), RH, dew point (DP) temperature and black globe temperature (BGT) for determining the temperature BGT were collected, and physiological parameters such as respiratory rate (RR), heart rate (HR), rectal temperature (RT) and surface temperature (ST) for the determination of heat tolerance as Iberia or Rhoad and adaptability of tests like Benezra (AC1 and AC2), test the determination of thermal gradients was done by the difference between rectal and surface temperatures (RT-ST) and between the surface and ambient temperatures (ST-AT) as adaptability parameter. For the evaluation of the technique of feeding behavior instantaneous scan every five minutes was used. For nutrient intake and digestibility animals were kept in cages for determination of metabolism during the entire experimental period making the total collection of feces, feed and feed leftovers. The experimental design was completely randomized with four treatments (temperature), six replicates (animals). Data were evaluated by analysis of variance, and when significant, were compared by Tukey test at 5% probability for determining the nutrient intake regression analysis was done. The results indicated that the BGHI temperatures 20, 24 °C gave adequate weather race. Statistical difference was observed with increasing temperature for the ST, HR and RR, and the RT remained constant and within normal limits. For the physiological parameters and temperature gradients, temperature effect was observed (P<0.05) with increasing temperature within the chamber, as well as the records for the Iberia and AC1 and AC2 test, with change with increasing temperature inside the chamber. Chewing behavior there was a greater demand for water with increasing temperature and there was a decrease in food intake, but there were no differences for the consumption of nutrients (EEC, CP and NDF). Thus we can say that Anglo Nubian goat breed is demonstrated highly-adapted conditions studied.
48

Refrigeração evaporativa de telhados por meio de gotejamento de água. Experimento em bancada de testes.

Nascimento, Gustavo Rosas 09 December 2005 (has links)
Made available in DSpace on 2016-06-02T20:09:24Z (GMT). No. of bitstreams: 1 DissGRN.pdf: 2609082 bytes, checksum: 09147cf07533f0a088d8e1734fc80ee4 (MD5) Previous issue date: 2005-12-09 / Financiadora de Estudos e Projetos / The cooling effect of evaporation is used in dry climates buildings since ancient times. Water evaporation can remove heat of roofs, cooling the interior of buildings indirectly. This study presents the measurement results of a test bed which received two identical tiles, one of them receiving water application and the other kept dry. Its objective was to investigate the effects that the evaporation provokes on internal surface temperature of ceramic tiles and fibrocement tiles. Using regression analyses, strong correlations were found among the falls observed in tiles internal surface temperatures and the climatic conditions. The evaporation provoked reduction of until 18,7 oC in the ceramic roof and until 17ºC reduction in the fibrocement one. / O resfriamento evaporativo de ambientes é conhecido pelos habitantes de regiões de clima seco desde a antiguidade. A evaporação de água sobre coberturas retira calor das mesmas, refrigerando indiretamente o interior da edificação. Este trabalho apresenta resultados de um estudo em que foram medidos os efeitos que a evaporação provoca sobre as temperaturas superficiais internas de telhas de barro e de fibrocimento, sujeitas às variações climáticas como o vento e radiação solar. Para tanto, montou-se uma bancada de testes onde foram monitoradas telhas idênticas, uma com gotejamento de água e outra mantida seca, em situações de inverno em laboratório e em situações de verão em campo. Por meio de análise de regressão, identificou-se fortes correlações entre as quedas observadas nas temperaturas superficiais internas das telhas e as condições climáticas. A evaporação provocou redução de até 18,7 ºC na temperatura superficial interna da telha de barro e de até 17ºC na de telha de fibrocimento. Os resultados indicaram que o gotejamento de água sobre superfícies externas de telhas de barro e de fibrocimento reduz a temperatura superficial interna das mesmas por meio da refrigeração evaporativa, sendo um potencial método de resfriamento passivo de telhados de barro e de fibrocimento na região de São Carlos-SP.
49

Metodologías gráficas para la estimación de la incidencia de la Radiación Solar sobre superficies

Ferrer Ferrer, Juan 21 March 2016 (has links)
[EN] The solar power has been and continues being the original and primary source of energy. With the exception of some sources of energy such us the nuclear one, or the tidal one, the rest of sources of energy come directly or indirectly of the Sun. The utilization of a source of energy supposes the exploitation of a natural resource, this utilization can have negative implications for the environment. The European Union has led the international effort to control the causative factors of the climate change, trying to identify profitable measures that could reduce the emission. Objectives: The objective of this PhD thesis is to develop a graphical procedure to allow assessment of the impact of solar radiation on surfaces. To do so a three-dimensional geometry model under consideration and the surrounding environment will be used. Since result there will be obtained the values of radiation owed to the direct component and due to the diffuse component, distinguished for every point of the model. For the obtaining of the values the procedure bears the meteorology of the zone in mind, the shades produced by the environment on the model and the produced by the model on itself. The graphical results will be stored as bitmap images in grayscale, there being established for every value of grey a value of received radiation. Defined an environment with a geographical certain orientation and position, the methodology will allow to evaluate the incidental radiation, for a concrete period, on every point of the surfaces of the model. Methodology: - Validation of graphical methods. This block has divided in four sections. In the first sections there is defined the methodology of work applied in the rest of them. The second section, one proposes a methodology for the calculation of the solar incident angle. In other two sections there appear and validate the models of estimation of the direct and diffuse radiation. Obtaining a correlation between the values of grey assigned to a surface and the component of the radiation got for the same one, either direct or diffuse. - Procedure of accumulation of maps. In this block, the concepts of irradiance map and irradiation map are defined, beside specifying how they are generated from the meteorological information and the images obtained of the model. It also presents the methodology to add maps allowing the accumulation of values for periods superior to an hour. There has been defined a method that, starting from a irradiation map, allows to know the average irradiation got for a surface represented by an area of the same one. In another paragraph there define the energies map, the cosines map and the function Energy that allows to know the energy that receive the surfaces represented in the area selected of the map. - Methods for comparing maps. Useful for the analysis of results. - Implementation One possible implementation of the proposed methodology is presented, presenting the tools chosen. For part of the accumulation maps it has been chosen to develop our own application. - Example of use. Practical example that the implementation of the developed methodology is used. Results and discussions: In this paragraph there appear three cases of study on which the implementation of the methodology will be applied obtaining the results. The choice of the cases is not chance, and has been realized attending to different criteria. Different geographical zones have been chosen, having different latitudes. It has been tried that the studied geometries were guarding certain similarities in order to be able to compare results. / [ES] La energía solar ha sido y continúa siendo la fuente original y primaria de energía. A excepción de algunas fuentes de energía como pueden ser la nuclear, o la mareomotriz, el resto de fuentes de energía provienen directa o indirectamente del sol. La utilización de una fuente de energía supone la explotación de un recurso natural, este aprovechamiento puede tener implicaciones negativas para el medio ambiente. La Unión Europea ha liderado el esfuerzo internacional para controlar los factores causantes del cambio climático, tratando de identificar medidas rentables que puedan reducir las emisiones. Objetivos: El objeto de la presente Tesis Doctoral es desarrollar un procedimiento gráfico que permita la evaluación de la incidencia de la radiación solar sobre las superficies. Para ello se utilizará un modelo tridimensional tanto de la geometría objeto de estudio como del entorno que la rodea. Como resultado se obtendrán los valores de radiación debidos a la componente directa y los debidos a la componente difusa, particularizados para cada punto del modelo. Para la obtención de los valores el procedimiento tiene en cuenta la meteorología de la zona las sombras producidas por el entorno sobre el modelo y las producidas por el modelo sobre sí mismo. Los resultados gráficos serán almacenados en forma de imágenes de mapa de bits en escala de grises, estableciéndose para cada valor de gris un valor de radiación recibida. Definido un entorno con una orientación y posición geográficas determinadas, la metodología permitirá evaluar la radiación incidente, para un periodo concreto, sobre cada punto de las superficies del modelo. Metodología: - Validación de métodos gráficos. Este bloque se ha dividido en cuatro apartados. En el primer apartado se define la metodología de trabajo aplicada en el resto de ellos. En el segundo apartado, se propone una metodología para el cálculo del ángulo de la incidencia solar. En los otros dos apartados se plantean y validan los modelos de estimación de la radiación directa y difusa. Obteniendo una correlación entre los valores de gris asignados a una superficie y la componente de la radiación recibida por la misma, bien sea directa o difusa. - Procedimiento de acumulación de mapas. En este bloque se definen los conceptos de mapa de irradiancias y de mapa de irradiación, además de especificar cómo se generan a partir de los datos meteorológicos y las imágenes obtenidas del modelo. También se presenta la metodología para sumar mapas permitiendo la acumulación de valores para periodos superiores a una hora. Se ha definido un método que, partiendo de un mapa de irradiaciones, permite conocer la irradiación media recibida por una superficie representada por un área del mismo. En otro apartado se definen el mapa de energías, el mapa de cosenos y la función Energía que permite conocer la energía que reciben las superficies representadas en el área seleccionada del mapa. - Métodos para la comparación de mapas. Útiles para el análisis de resultados. - Implementación Se presenta una posible implementación de la metodología propuesta, presentando las herramientas informáticas elegidas. Para la parte de la acumulación de mapas se ha optado por desarrollar una aplicación propia. - Ejemplo de utilización. Ejemplo práctico en que se utiliza la implementación de la metodología desarrollada. Resultados y discusiones: En este apartado se plantean tres casos de estudio sobre los que se aplicará la implementación de la metodología obteniendo los resultados. La elección de los casos no es casual, y se ha realizado atendiendo a diferentes criterios. Se han elegido diferentes zonas geográficas, disponiendo de diferentes latitudes. Se ha tratado que las geometrías estudiadas guardaran ciertas similitudes a fin de poder comparar resultados. / [CAT] L'energia solar ha sigut i continua sent la font original i primària d'energia. A excepció d'algunes fonts d'energia com poden ser la nuclear, o la mareomotriu, la resta de fonts d'energia provenen directament o indirectament del sol. La utilització d'una font d'energia suposa l'explotació d'un recurs natural, aquest aprofitament pot tenir implicacions negatives per al medi ambient. La Unió Europea ha liderat l'esforç internacional per controlar els factors causants del canvi climàtic, tractant d'identificar mesures rendibles que puguen reduir les emissions. Objectius: L'objecte de la present Tesi Doctoral és desenvolupar un procediment gràfic que permeta l'avaluació de la incidència de la radiació solar sobre les superfícies. Per a això s'utilitzarà un model tridimensional tant de la geometria objecte d'estudi com de l'entorn que l'envolta. Com a resultat s'obtindran els valors de radiació deguts a la component directa i els deguts a la component difusa, particularitzats per a cada punt del model. Per a l'obtenció dels valors el procediment té en compte la meteorologia de la zona les ombres produïdes per l'entorn sobre el model i les produïdes pel model sobre si mateix. Els resultats gràfics seran emmagatzemats en forma d'imatges de mapa de bits en escala de grisos, establint-se per a cada valor de gris un valor de radiació rebuda. Definit un entorn amb una orientació i posició geogràfiques determinades, la metodologia permetrà avaluar la radiació incident, per a un període concret, sobre cada punt de les superfícies del model. Metodologia: - Validació de mètodes gràfics. Aquest bloc s'ha dividit en quatre apartats. Al primer apartat es defineix la metodologia de treball aplicada en la resta d'ells. En el segon apartat, es proposa una metodologia per al càlcul de l'angle de la incidència solar. En els altres dos apartats es plantegen i validen els models d'estimació de la radiació directa i difusa. Obtenint una correlació entre els valors de gris assignats a una superfície i la component de la radiació rebuda per la mateixa, bé siga directa o difusa. - Procediment d'acumulació de mapes. En aquest bloc es defineixen els conceptes de mapa d'irradiàncies i de mapa d'irradiació, a més d'especificar com es generen a partir de les dades meteorològiques i les imatges obtingudes del model. També es presenta la metodologia per sumar mapes permetent l'acumulació de valors per a períodes superiors a una hora. S'ha definit un mètode que, partint d'un mapa d'irradiacions, permet conéixer la irradiació mitjana rebuda per una superfície representada per una àrea del mateix. A un altre apartat es defineixen el mapa d'energies, el mapa de cosinus i la funció Energia que permet conéixer l'energia que reben les superfícies representades a l'àrea seleccionada del mapa. - Mètodes per a la comparació de mapes. Útils per a l'anàlisi de resultats. - Implementació. Es presenta una possible implementació de la metodologia proposada, presentant les eines informàtiques triades i la configuració utilitzada en les mateixes. Per a la part de l'acumulació de mapes s'ha optat per desenvolupar una aplicació pròpia. - Exemple d'utilització. Exemple pràctic en què s'utilitza la implementació de la metodologia desenvolupada. Resultats i discussions: En aquest apartat es plantegen tres casos d'estudi sobre els quals s'aplicarà la implementació de la metodologia obtenint els resultats. L'elecció dels casos no és casual, i s'ha realitzat atenent a diferents criteris. S'han triat diferents zones geogràfiques, disposant de diferents latituds. S'ha tractat que les geometries estudiades guardaren certes similituds a fi de poder comparar resultats. / Ferrer Ferrer, J. (2016). Metodologías gráficas para la estimación de la incidencia de la Radiación Solar sobre superficies [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/61973 / TESIS
50

Diseño Interior de un Centro de Educación Ambiental en la Ciudad Comercial Minka - Callao / Interior Design of an Environmental Education Center in the Minka’s Commercial City, Callao

Noriega Regies, Angela Giovanna 20 October 2021 (has links)
El presente trabajo de suficiencia profesional propone el Diseño Interior de un Centro de Educación Ambiental ubicado en la Ciudad Comercial Minka, Callao. La propuesta busca, a través del adecuado diseño de espacios, incrementar y reforzar el cuidado del Medio Ambiente y el estilo de vida sostenible, por medio de la enseñanza de cursos, talleres y exhibiciones con la metodología ASIRI (hacer, sentir y pensar). En primer lugar, se realizó el Levantamiento del predio a intervenir, el análisis de contexto comprendido por vías principales, accesos, circulación, uso de suelos e hitos, contaminación, plantas y estaciones de reciclaje, tanto a nivel Callao como Minka; el Análisis de preexistencia que abarca zonificación, ingresos, circulación, sistema constructivo, asoleamiento y vientos del predio y el Diagnóstico FODA con oportunidades y amenazas de Minka, y fortalezas y debilidades del establecimiento a intervenir. Después, se realizó un análisis de usuario y funciones para posteriormen- te poder plantear las estrategias necesarias como la organizativa, formal, espacial y de experiencia. Luego, se diseñó el Master Plan con los planos de distribución de los dos niveles, techos, cortes y elevaciones necesarias. Por último, se priorizó un sector por las actividades a realizar y el sistema constructivo; y se diseñaron las plantas de distribución en 1/25, techos, cortes, 2 cortes escantillón, pisos, muebles fijos y móviles, mobiliarios y detalles de los mismos, carpintería, FCR, rociadores,INDECI, iluminación e instalaciones eléctricas. / The present work of professional sufficiency proposes the Interior Design of an Environmental Education Center located in Minka’s Commercial City, Callao. The proposal seeks, through the adequate design of spaces, increase and reinforce the care of the Environment and the sustainable lifestyle, through the teaching of courses, workshopsand exhibitions with the ASIRI methodology (doing, feeling and thinking). In the first place, the drawing up of the property to be intervened was realized, as same as the context analysis with main roads, accesses, circulation, land use and milestones, pollution, plants and recycling stations, both at Callao and Minka levels; the Analysis of preexistence with zoning, circulation, construction system, sunlight and winds of the property and the SWOT Diagnosis with opportunities and threats of Minka, and strengths and weaknesses of the establishment to intervene. Afterwards, a user and function analysis was realized to be able to use the necessary strategies such as organizational, formal, spatial and experience. Then, the Master Plan was designed with the distribution plans of the two levels, ceilings, cuts and necessary eleva- tions. Finally, a sector was prioritized by the activities to be carried out and the system constructive, and the distribution plants were designed in 1/25, ceilings, cuts, 2 scantlings cuts, floors, fixed and mobile furniture, and details thereof, carpentry, FCR, sprinklers, INDECI, lighting and electrical installations. / Trabajo de Suficiencia Profesional

Page generated in 0.0579 seconds