• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 214
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 220
  • 210
  • 88
  • 82
  • 50
  • 38
  • 34
  • 29
  • 28
  • 28
  • 24
  • 21
  • 21
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Avaliação histopatológica em tecido conjuntivo subcutâneo de ratos de um cimento de ionômero de vidro experimental para forramento cavitário

Boaventura, Juliana Maria Capelozza [UNESP] 25 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-03-25Bitstream added on 2014-06-13T19:51:21Z : No. of bitstreams: 1 boaventura_jmc_me_arafo.pdf: 4140317 bytes, checksum: af588edb33c7ed7c016ce9297335cbb1 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O cimento de ionômero de vidro representa um marco dentro da Odontologia, pois veio agregar propriedades físicas e biológicas favoráveis que não eram obtidas com outros materiais. Uma de suas propriedades, a biocompatibilidade, foi o tema do nosso trabalho, que teve como objetivo avaliar, comparativamente, em tecido conjuntivo subcutâneo de ratos o potencial irritativo em nível I de um cimento de ionômero de vidro em fase experimental e o resultado da associação do pó experimental com o líquido de cimentos de ionômero de vidro já disponíveis comercialmente. Foram utilizados 60 ratos (Rattus norvegicus, Albinus, Holtzman), divididos em 5 grupos de 3 animais cada, para os períodos de 7,15, 30 e 60 dias. Os materiais utilizados foram: Vitrebond (Grupo I), Ionomaster F (Grupo II), Pó experimental + Líquido do Cimento de Ionômero de vidro Vitrebond (Grupo III), Pó experimental + Líquido do Cimento de Ionômero de vidro do Ionomaster F (Grupo IV) e Pó experimental + Líquido experimental (Grupo V). Pó e liquido experimentais foram desenvolvidos pelo Instituto de Química de Araraquara – UNESP/Brasil. O Vitrebond e Ionomaster F agiram como controle e todos foram veiculados em tubos de polietileno e implantados no tecido conjuntivo subcutâneo dos ratos. Decorridos os períodos experimentais, os tubos foram removidos e encaminhados para tramitação laboratorial. Os cortes foram avaliados em microscopia óptica comum para análise descritiva do quadro reacional. Considerando-se cada evento histopatológico foi apresentada a estatística descritiva de cada grupo. A avaliação de diferença significativa entre os materiais, considerando os períodos experimentais e os escores atribuídos aos eventos histopatológicos em estudo, foi realizada pelo teste de Kruskal – Wallis. Adicionalmente, foram efetuadas comparações múltiplas de postos médios pelo teste de Dunn. / Glass ionomer cement represents a hallmark in the Dentistry Science, since it aggregates favorable physical and biological properties, which were not obtained by the other cements. Biocompatibility, one of its properties, was the aim of this study, which was to evaluate, comparably, in the subcutaneous tissue of rats, the level I aggravation potential of glass ionomer cement in experimental phase and the result between the association of the experimental powder and the liquid from commercially available glass ionomer cements. Sixty rats were used (Rattus novergicus, Albinus, Holtzman), divided into 5 groups of 3 animals each, in the following time periods of 7, 15, 30 and 60 days. Commercial materials used were: Vitrebond (Group I), Ionomaster F (Group II), Experimental powder + Liquid of Glass Ionomer Cement Vitrebond (Group III), Experimental powder + Liquid of Glass Ionomer Cement Ionomaster F (Group IV), and Experimental powder + Experimental Liquid (Group V). Experimental powder and liquid were developed by Chemical Institute of Araraquara – UNESP/Brasil. Vitrebond and Ionomaster F were utilized as control and every group were carried within poly (ethylene) tubes and implanted in the subcutaneous connective tissue of the rats. Tubes were removed after the appropriate experimental times and were taken to laboratory processing. Cuts were evaluated under optical light microscopy to obtain descriptive analyze of the reaction overview. According to each histopathological event, descriptive statistics were presented to each group. The significant difference evaluation among materials, considering experimental times and scores attributed to the histopathological events studied, was performed by Kruskal-Wallis test. Besides this, multiple comparisons were effectuated of mean points by Dunn test.
182

Reação tecidual e detecção de Interleucina-6 promovida por cimentos à base de silicato de cálcio no subcutâneo de ratos / Tissue reaction and detection of interleukin-6 promoted by calcium silicate based sealers in rat subcutaneous

Saraiva, Juliana Alcarás [UNESP] 15 March 2017 (has links)
Submitted by Juliana Alcarás Saraiva null (julialcaras@yahoo.com.br) on 2017-08-31T14:25:03Z No. of bitstreams: 1 TESE VERSÃO FINAL CORRIGIDA PARA SITE UNESP.pdf: 2080588 bytes, checksum: 3dd6331df6003b31574fbe62b17fba5d (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-09-01T13:43:23Z (GMT) No. of bitstreams: 1 saraiva_ja_dr_arafo.pdf: 2080588 bytes, checksum: 3dd6331df6003b31574fbe62b17fba5d (MD5) / Made available in DSpace on 2017-09-01T13:43:23Z (GMT). No. of bitstreams: 1 saraiva_ja_dr_arafo.pdf: 2080588 bytes, checksum: 3dd6331df6003b31574fbe62b17fba5d (MD5) Previous issue date: 2017-03-15 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a reação tecidual promovida pelos cimentos endodônticos MTA Plus e MTA Fillapex em comparação ao AH Plus, usado como padrão “ouro”, e ao Endofill, considerado como controle positivo, no subcutâneo de ratos. Foram utilizados 100 animais e em cada foi inserido no tecido subcutâneo dorsal um tubo de polietileno preenchido com MTA Plus, MTA Fillapex, AH Plus, Endofill ou vazio (grupo controle). Após 7, 15, 30 e 60 dias, os tubos implantados e os tecidos circundantes foram removidos, fixados e incluídos em parafina. Nos cortes corados com HE, a densidade de volume de células inflamatórias (VvCI) e fibroblastos (VvFb) foi estimada nas cápsulas. Imuno-histoquímica para detecção de interleucina-6 (IL-6) foi realizada e a densidade numérica de células imunopositivas foi computada. O conteúdo de colágeno birrefringente nas cápsulas foi quantificado nos cortes corados com picrosirius e analisados sob luz polarizada. Os dados foram analisados pelo ANOVA e teste de Tukey (p≤0,05). Aos 7 dias, as cápsulas apresentaram reação inflamatória moderada. Em todos os grupos, a VvCI e as células imunopositivas para IL-6 reduziram significantemente de 7 para 60 dias. Aos 60 dias, o número de células imunopositivas para IL-6 foi significantemente reduzido nos grupos MTA Plus e MTA Fillapex em comparação ao AH Plus; diferenças significantes na VvCI entre MTA Plus, MTA Fillapex, AH Plus e grupo controle não foram observadas, enquanto que o Endofill exibiu a maior VvCI. A redução da VvCI foi paralela ao aumento do conteúdo de colágeno nas cápsulas de todos os grupos, exceto no Endofill. Portanto, o MTA Plus, MTA Fillapex e AH Plus induziram uma resposta que culmina na regressão da inflamação e formação de uma cápsula fibrosa com o decorrer do tempo. Considerando que a imunoexpressão para IL-6 reduziu significativamente nos grupos MTA Plus e MTA Fillapex, é possível sugerir que estes cimentos endodônticos possam favorecer a regressão da lesão periapical. / We evaluated the tissue reaction promoted by MTA Plus, MTA Fillapex, AH Plus and Endofill in the rat subcutaneous. Polyethylene tubes filled with MTA Plus, MTA Fillapex, AH Plus or Endofill were implanted in the rat subcutaneous. In the control group (CG), empty tubes were implanted. After 7, 15, 30 and 60 days, the tubes surrounded by connective tissue were paraffin-embedded. In HE-stained sections, the volume density of inflammatory cells (VvIC) and fibroblasts (VvFb) was estimated in the capsules. Immunohistochemistry (IH) for interleukin-6 (IL-6) was performed, and the number of IL-6-immunolabeled cells was obtained. The birefringent collagen content was quantified in picrosirius-red-stained sections under polarized light. Data were analyzed by ANOVA and Tukey tests (p≤0.05). At 7 days, capsules showed moderate inflammatory reaction, and VvIC and IL-6-immunolabeled cells were similar either in the capsules adjacent to the sealers or in CG. In all groups, VvIC and IL-6 IH reduced significantly from 7 to 60 days. At 60 days, IL-6 IH was reduced significantly in MTA Plus and MTA Fillapex in comparison to AH Plus; no difference was found in the VvIC among MTA Plus, MTA Fillapex, AH Plus and CG whereas Endofill exhibited the highest VvIC. The reduction in VvIC was parallel to an increase in the collagen content in the capsules of in all groups, except Endofill. MTA Plus, MTA Fillapex and AH Plus induce a response that culminates in the regression of inflammation and formation of a fibrous capsule over time. Considering that IL-6 immunoexpression significantly reduced in the MTA Plus and MTA Fillapex groups, it is possible to suggest that these endodontic sealers may favor the regression of the periapical lesion.
183

Cimento de ionômero de vidro modificado com sal imidazólico : biomaterial funcionalizado com propriedades antibiofilme fúngico

Ehrhardt, Alexandre January 2017 (has links)
Os cimentos de ionômero de vidro são biomateriais constituídos de polímeros ácidos, vidro básico (ionizável) e água, sendo usados amplamente no campo odontológico, como materiais restauradores ou ainda como cimentadores de bandas ortodônticas. Estes compostos podem ser suscetíveis a formação de biofilmes por espécies de Candida na sua superfície em função da rugosidade associada a colonização fúngica do meio bucal. Pesquisas na área de desenvolvimento de biomateriais funcionais tem buscado desenvolver compostos de alta eficácia e baixa toxicidade que sejam capazes de inibir a formação de biofilmes sobre superfícies biológicas. Considerando a busca por novos biomateriais, foi desenvolvido um estudo ex vivo com o objetivo de modificar a estrutura de um cimento de ionômero de vidro comercialmente disponível (Ketac® Cem Easymix 3M) através da inserção do sal imidazólico cloreto de 1-nhexadecil- 3-metilimidazol comparado ao cloreto de cetilpiridínio para compor um novo composto com atividade antibiofilme. O sal imidazólico e o cloreto de cetilpiridínio foram acrescentados diretamente ao pó do ionômero de vidro na proporção de 10 ppm p/p. A partir desta adição inicial, foi realizada a reação de polimerização do ionômero, obtendo corpos de prova (CP) medindo 5 mm Ø × 3 mm h, os quais foram divididos em 03 grupos: CP1, constituído do ionômero na formulação original (controle de crescimento de biofilme); CP2, constituído do ionômero acrescido com o cloreto de cetilpiridínio (referência) e CP3, constituído do ionômero acrescido do sal imidazólico. Foram testadas nove cepas de Candida não albicans resistentes ao antifúngicos usuais, sendo três cepas de C. glabrata (RL22, RL24 e RL25), três cepas de C. tropicalis (57A, 72A e 72P) e três cepas de C. parapsilosis (RL11, RL20 e RL32), todas depositadas no Laboratório de Micologia da UFRGS. Avaliou-se a resistência a deformação plástica pelo teste de microdureza; a atividade antibiofilme pela avaliação de inibição de crescimento na superfície dos CP por microscopia eletrônica de varredura e avaliação de hipoalerginicidade pelo teste da membrana cório-alantoide. O teste de microdureza não apresentou diferença significativa (p>0,05) entre os três grupos, com valor médio de 44.2 HV para o CP1, 43.5 HV para o CP2 e 43,1 HV para o CP3. A avaliação da superfície dos CP através da análise de microscopia eletrônica demonstrou haver inibição completa da formação do biofilme de todas as cepas testadas. O teste da membrana cório-alantoide indicou que o ionômero de vidro na sua composição original, bem como acrescido dos dois compostos testados, demonstrou ser hipoalergênico. Considerando os dados apresentados, podemos concluir que a adição do sal imidazólico na formulação do ionômero de vidro promoveu a ação antibiofilme contra cepas multirresistente sem perda nas características de microdureza e hipoalergenicidade. / Glass ionomer cements are biomaterials composed of acid polymers, basic glass (ionizable) and water, being widely used in dentistry, as restorative materials or as orthodontic bands. These compounds may be susceptible to biofilm formation on their surface by Candida species because of the roughness associated with fungal colonization of the oral cavity. Research on antifungal drugs development has focused on the synthesis of new compounds, that present effective action and low toxicity that are able to inhibit the formation of biofilms on biological surfaces. Considering the demand for biomaterials with antibiofilm activity, an ex vivo study was developed with the objective of modifying the structure of a commercially available glass ionomer cement (Ketac® Cem Easymix 3M) by insertion of the imidazole salt 1-n-hexadecyl-3- methylimidazole chloride compared to the cetylpyridinium chloride to make a novel compound with antibiofilm activity. The imidazole salt and cetylpyridinium chloride were added directly to the glass ionomer powder at a ratio of 10 ppm w/w. From this initial addition, the ionomer polymerization reaction was performed, obtaining test specimens (TS) measuring 5 mm Ø × 3 mm h, divided into three groups; i) TS1, composed only of GIC (growth control reference); ii) TS2, glass ionomer and cetylpyridinium chloride added directly to the powder (drug reference); and iii) TS3, glass ionomer and imidazolium salt using the same procedure. Nine strains of nonalbicans Candida, resistant to usual antifungals, were used; three C. glabrata strains (RL22, RL24 and RL25), three C. tropicalis strains (57A, 72A and 72P) and three C. Parapsilosis strains (RL11, RL20 and RL32), all the strains are deposited in the Mycology Collection at UFRGS. The plastic deformation was evaluated by the microhardness test; the antibiofilm activity by the evaluation of inhibition of growth on the surface of the specimens by scanning electron microscopy and evaluation of hypoallerginicity by the test of the chorioallantoic membrane. The plastic deformation evaluation showed no significant difference among the three groups, with a mean value of 44.2 HV for TS1, 43.5 HV for TS2 and 43,1 HV for TS3. Evaluating the biofilm formation on TSs, all the isolates form biofilm on TS1 (reference). On the other hand, both TS2 and TS3 were able to inhibit surface biofilm growth. The allergenicity evaluation of the three TSs showed no evidence of tissue alteration, considering that the eggs’ chorioallantoic membrane remained intact. Considering the presented data, we can conclude that the addition of the imidazole salt in the glass ionomer formulation promoted the antibiofilm action against multiresistant strains without loss in the characteristics of microhardness and hypoallergenicity.
184

Interação entre células e biomateriaispara desenvolvimento de neovagina : ensaios in vitro

Henckes, Nicole Andrea Corbellini January 2017 (has links)
A síndrome de Mayer-Rokitansky-Kuster-Hauser (MRKH) caracteriza-se pela aplasia congênita dos ductos Mullerianos. Devido a algumas características peculiares, as células-tronco mesenquimais estão sendo vistas como uma nova alternativa de tratamento em pacientes acometidos pela síndrome de MRKH. Considerando que alguns biomateriais servem como suporte estrutural e interferem positivamente na regeneração tecidual, a associação da linhagem celular de mucosa vaginal HMV-II e das MSC derivadas de tecido adiposo humano com biomateriais apresenta uma nova possibilidade na criação de neovagina. Nesta perspectiva, foram cultivadas células HMV-II com diferentes biomateriais (Membracel, Biofilme, Cellprene, PLGA PI quimicamente modificado) a fim de selecionar o melhor material alternativo. Ambas as células, associadas ao biomaterial selecionado, foram submetidas à análise morfológica, coloração ácido periódico-Schiff (PAS), expressão de marcadores epiteliais específicos por imunofluorescência e microcopia eletrônica de varredura (MEV). As células que interagiram com o biomaterial apresentaram marcadores epiteliais específicos e características morfológicas epiteliais. Estes resultados indicam que a interação do biomaterial com ambas as células testadas tem potencial capacidade para uma epitelização eficiente da neovagina. O crescimento das MSC com o biomaterial selecionado para implantação subsequente em pacientes com síndrome de MRKH pode representar uma alternativa válida e promissora para a reconstrução vaginal. / The Mayer-Rokitansky-Kuster-Hauser (MRKH) syndrome is characterized by congenital aplasia of the Mullerian ducts. Because mesenchymal stem cells (MSCs) secrete paracrine factors, they have been seen as a new treatment option for several diseases. Considering that some biomaterials can be used as scaffolds and interfere positively in tissue regeneration, the association of human vaginal mucosa (HMV-II) cell line and MSCs with biomaterials appears as a new option for the creation of neovagina. In this study we cultured HMV-II cells with different biomaterials (Membracel, Biofilm, Cellprene, chemically modified PLGA PI) to select the best alternative material. For that both cells were cultured with the selected biomaterial and evaluated by morphological analysis, periodic acid-Schiff (PAS) staining, expression of epithelial markers by immunofluorescence and scanning electron microscopy (SEM). The analysis of the in vitro cell-biomaterial interactions showed specific epithelial markers and epithelial morphological features for both cells. These results indicate that the interaction of the biomaterial with the two tested cells has the potential capacity for an efficient epithelialization of the neovagina. Therefore, growth of MSCs with the selected biomaterial for subsequent implantation in patients with MRKH syndrome may represent a valid and promising alternative for vaginal reconstruction.
185

Aloenxertos ósseos e enxerto sintético de hidroxiapatita em falha óssea ulnar em galinhas (Gallus gallus domesticus)

Schmitt, Bernardo January 2018 (has links)
A utilização de enxertos ósseos vem aumentando bastante em pequenos animais, entretanto, em aves esta utilização é menor devido à dificuldade de conseguir autoenxerto em quantidades adequadas. Sendo assim, o objetivo do projeto foi avaliar três tipos de enxertos em aves. Foram utilizadas 30 galinhas separadas em três grupos: grupo aloenxerto congelado em ultrafreezer (GUF) por duas semanas; grupo aloenxerto congelado em nitrogênio líquido (GNL) e grupo enxerto sintético de hidroxiapatita deficiente em cálcio (GHA). Os enxertos foram aplicados em defeito ósseo de aproximadamente 20mm na ulna das aves e fixados ao leito receptor com uma placa e quatro parafusos bloqueados. Os animais foram acompanhados por meio de avaliação clínica, radiográfica, histológica e biomecânica. A consolidação radiográfica ocorreu em 90% nos animais do GNL, 70% nos do GUF e 60% nos do GHA, com média de 47,14±13,50 dias no GUF, 61,67±21,79 dias no GNL e aos 70±18,17 dias no GHA, havendo diferença significativa entre o GUF e GHA. Histologicamente os enxertos do GUF apresentavam-se em processo de consolidação mais avançada, com remodelação óssea e a presença de osteoclastos. Na avaliação clínica todas as ulnas operadas tinham estabilidade, sem sinal de inflamação/contaminação, articulações preservadas, sem dor e sem desvios angulares graves na asa. Na análise biomecânica houve diferença significativa (p<0,05) entre o GNL e o GHA na resistência, já na avaliação de flexão máxima, observou-se diferença estatística entre o GHA e o GNL e entre o GHA e o GUF. Sendo assim, é possível concluir que os três enxertos testados podem ser utilizados em defeitos ósseos em aves, mas o melhor deles foi o GNL por apresentar mais vantagens na preparação, confecção, aplicação dos enxertos e resistência biomecânica, com maior taxa de consolidação óssea. / The use of bone grafts is increasing considerably in small animals, however, in poultry this use is less due to the difficulty of obtaining autograft in adequate quantities. Therefore, the objective of the project was to test three types of grafts, evaluating their best results over a period of 90 days. For this purpose, 30 chickens were divided into three groups: frozen ultra freezer allograft group (UFG) for two weeks; allograft frozen in liquid nitrogen group (LNG) and synthetic grafts of calcium deficient hydroxyapatite group (HAG). Grafts were applied to a bone defect of approximately 20 mm in the ulna of birds, in all three groups the grafts were fixed to the recipient bed with plates blocked and 4 screws locked. The animals were followed up by serial radiographs, histological examination, clinical orthopedic evaluation and biomechanical flexion assay. Radiographic consolidation occurred in 90% of the LNG, 70% in the GUF and 60% in the GHA, mean of 47.14 ± 13.50 days without UFG, 61.67 ± 21.79 days non LNG and at 70 ± 18.17 days without HAG, with a significant difference between UFG and HAG. Histologically, UFG grafts were in a more advanced consolidation process, presenting bone remodeling with a presence of osteoclasts In the clinical review, all of them were operated with stability, with no sign of inflammation / contamination, preserved joints, no pain and no angular deviations, graves in the nail. In the biomechanics, there was a significant difference (p <0.05) between LNG and HAG in the resistance, already in the evaluation of maximum flexion, it was observed statistical difference not HAG with LNG and HAG with UFG grafts. Thus, it is possible to conclude that the three grafts tested are feasible to be used in bone loss in birds, where the LNG was superior because it presented more advantages in the preparation, preparation and application of the grafts, presenting a higher rate of bone consolidation.
186

Resposta inflamatória imediata de cinco cimentos endodônticos diante do teste edemogênico em subcutâneo de ratos / Immediate inflammatory response of five endodontic sealers using the edemogenic test in subcutaneous of mice

Rocio Anahi Zaragoza Douglas 01 April 2008 (has links)
Este estudo teve como objetivo avaliar, in vivo, por um período de 24h, a resposta tecidual inflamatória subcutânea após a utilização de cimentos endodônticos. Realizouse a seleção de 75 ratos, machos, da linhagem Wistar, de aproximadamente 90 dias (de vida) e com cerca de 350g (de peso), que foram aleatoriamente distribuídos em 5 grupos (n=20), como se segue: G1 - ActiV GPTM, G2 - Biosealer, G3 - RealSeal®, G4 - RoekoSeal® e G5 - AH Plus®. A resposta inflamatória foi observada pelo teste edemogênico, nos tempos 6, 12 e 24 horas. Como protocolo de aplicação da metodologia, os animais depois de anestesiados, receberam uma injeção do corante vital Azul de Evans na veia lateral caudal. Em seguida, foram tricotomizados em seu dorso e, doses iguais dos materiais estudados foram inseridas subcutaneamente. Ao final de cada período de tempo, realizou-se a remoção da pele dorsal em fragmentos de 15 mm de diâmetro. Os fragmentos foram imersos em solução de formamida P.A., armazenados em estufa a 37ºC, por 48 horas. Nesse momento, os índices de absorbância do corante extraído pelo solvente foram quantificados por meio de espectrofotometria, os resultados convertidos em microgramas (?g) e a concentração de cada substância no infiltrado inflamatório obtida. Os dados obtidos foram submetidos a ANOVA e teste de Tukey (p<0,05). E, de acordo com os resultados obtidos, observou-se que houve diferenças estatisticamente significativas para os fatores em estudo material (p<0,0001) e tempo (p<0,0001), entretanto não houve interação material*tempo (p=0,128). Sendo assim, nas primeiras 6h, a ordem decrescente de irritabilidade dos materiais analisados foi: G3 ? G5 > G1 > G2 > G4. Entretanto, os materiais desempenharam-se de forma semelhante, tanto no tempo de 12h quanto no de 24h, como se segue: G1 ? G3 ? G5 > G2 ? G4. Desta forma, pôde-se concluir que: 1 - o cimento RoekoSeal demonstrou o menor grau de irritabilidade no tempo experimental de 6 horas; 2 - Os cimentos RealSeal e AH Plus apresentaram resposta inflamatória mais intensa no período experimental de 6 horas e 3 - o índice de irritabilidade nas primeiras 6 horas é significativamente superior quando comparado ao período de 24h, independente do material testado. / The aim of this study was evaluate in vivo the earliest 24 hours tissue inflammatory response to five endodontic sealers. In order to this, 75 male rats Wistar with 90 days of age and approximately 350g of weight were divided in 5 experimental groups (n=20): G1 - ActiV GPTM, G2 - Biosealer, G3 - RealSeal®, G4 - RoekoSeal® e G5 - AH Plus®. The inflammatory response was evaluated using the edemogenic test in the experimental periods of 06, 12 and 24 hours. Anesthetized mice received an Evan´s blue dye injection in the lateral caudal vein and were tricotomized in the dorsum where equal amounts of each sealer were subcutaneously inoculated. After experimental period, the mice were sacrified, the dorsal skin was excised and pieces with 15mm of diameter around each inoculated sealer were removed. Each tissue piece was reduced to fragments, immersed in formamide solution and stored at 37ºC during 48 hours. At this moment, the absorbance index of the dye extracted by the solvent was quantified using light absorption spectrometry, the results were converted to micrograms (?g) and their concentration in the inflammatory infiltrated was obtained. The data was submitted to statistical analysis using the ANOVA followed by the Tukey test (p<0.05) and the results showed statistical significant difference for analyzed factors, the material and the time (p<0.001); without interaction between both (p=0.128). Thus, in decrescent order inflammatory response, the groups were scaled: G3 ? G5 > G1 > G2 > G4 for 6 hours, and G1 ? G3 ? G5 > G2 ? G4 for 12 hours and 24 hours. Our findings indicated that: 1 - The RoekoSeal presented the minor inflammatory response value in the 6 hours experimental period; 2 - The RealSeal and AH Plus sealers showed intense inflammatory response in the experimental period of 6 hours; 3 - The inflammatory values at 6 hours were significantly higher compared with results in the period of 24 hours independently of the tested material.
187

Avaliação in vitro da citotoxicidade de instrumentos cirúrgicos enxaguados com diferentes qualidades de água. / Assessment of in vitro cytotoxicity of surgical instruments rinsed with different qualities of water

Rafael Queiroz de Souza 16 July 2014 (has links)
Introdução: O Centro de Material e Esterilização (CME) deve garantir a remoção completa de resíduos orgânicos e inorgânicos, sobretudo detergentes e endotoxinas, dos produtos críticos para saúde por meio do enxágue suficiente com água de qualidade. Com base nos recentes relatos de síndromes tóxicas do segmento anterior ocular, que foram associadas às más práticas de processamento do instrumental de oftalmologia, especialmente, a qualidade da água utilizada em seu enxágue final, esta Tese teceu a hipótese de que quanto mais pura for a qualidade da água do último enxágue, menor será a citotoxicidade encontrada nos produtos para saúde. Objetivo: Avaliar a citotoxicidade de cânulas de hidrodissecção submetidas à contaminação desafio, limpeza automatizada com enxágue final em diferentes qualidades de água: de torneira, tratada por deionizador, por destilação, por osmose reversa e por ultrapurificação. Métodos: 130 cânulas de hidrodissecção foram usadas, 26 por grupo experimental, caracterizados, de acordo com a água utilizada no último enxágue. As amostras foram submetidas à contaminação desafio interna e externamente por uma solução contendo 20% sangue de carneiro desfibrinado e 80% de Cloreto de Sódio a 0,9%, para simular um cenário desafiador de sujidade no material cirúrgico oftalmológico, sendo em seguida processadas, de acordo com um procedimento operacional padrão validado para este tipo de cânula, variando-se apenas a qualidade de água no enxágue final. Como controle positivo, foram utilizadas três cânulas descartáveis, que foram submetidas ao mesmo procedimento de contaminação desafio, imersas em uma solução contendo água de torneira e detergente enzimático que, após a evaporação da solução, foram esterilizadas. Para o controle negativo, foram usadas três cânulas das mesmas utilizadas nos grupos experimentais, com o mínimo de manipulação e na forma como foram fornecidas pelo fabricante, tendo sido apenas esterilizadas. Adicionalmente, foi incluído um grupo comparativo, no qual três amostras foram processadas em condições idênticas às dos grupos experimentais, enxaguadas com água de torneira, porém, sem secagem. Sequencialmente, procedeu-se a realização do teste de citotoxicidade pela incorporação do corante vital vermelho neutro para a obtenção da média da viabilidade celular de cada grupo experimental. Resultados: Ausência de citotoxicidade nos extratos das amostras, independente da diluição considerada na análise, sendo 83% a porcentagem média de viabilidade celular mínima obtida no extrato das amostras enxaguadas com água tratada por destilação na diluição de 12,5%. Conclusão: As cânulas de hidrodissecção não demonstraram citotoxicidade, independentemente da qualidade de água utilizada no último enxágue. Os resultados apresentados puderam ser alcançados unicamente por meio do uso de um procedimento operacional padrão de limpeza validado, baseado em literatura científica, em recomendações oficiais e na legislação relacionada. / Introduction: The Central Sterile Supply Department (CSSD) must guarantee the complete removal of organic and inorganic waste, especially detergents and endotoxins, from critical medical devices through sufficient rinsing with good-quality water. Based on recent reports of toxic anterior segment syndromes, which were associated with poor processing practices of ophthalmology instruments, particularly the quality of water used in the final rinse, this thesis has raised the hypothesis that the better the quality of the water used in the last rinse, the lower the cytotoxicity found in medical devices. Objective: To evaluate the cytotoxicity of hydrodissection cannulas, that were submitted to contamination challenge and then automated cleaning with final rinse in different qualities of water: tap water, water treated by a deionizer device, by distillation, by reverse osmosis and by ultrapurification. Methods: 130 hydrodissection cannulas were used, 26 per experimental group, characterized according to the last rinse water used. The samples were submitted to internal and external contamination challenge using a solution containing 20% defibrinated sheep blood and 80% Sodium Chloride at 0.9%, to simulate a challenging scenario of soiled ophthalmic surgical material, which was then processed, according to a validated standard operating procedure for this type of cannula, changing only the quality of water at the final rinse. Three disposable cannulas were used as positive controls, being submitted to the same contamination challenge procedure, then immersed in a solution containing tap water and enzymatic detergent, and then sterilized after evaporation of the solution. Three cannulas, identical to those used in the experimental groups, were used as negative controls, after minimum handling and exactly as they were supplied by the manufacturer, having only been sterilized. Additionally, a comparison group was included, from which three samples were processed under conditions identical to the experimental groups, rinsed with tap water, but without drying. Sequentially, the cytotoxicity assay was performed by incorporating the neutral red vital dye to obtain mean cell viability from each experimental group. Results: We observed absence of cytotoxicity in the sample extracts, regardless of the dilution considered in the analysis, with 83% of minimal cell viability obtained in the sample extract rinsed with distilled water at 12.5% dilution. Conclusion: Hydrodissection cannulas showed no cytotoxicity, regardless of the quality of water used in the final rinse. The results shown here were achieved by using a validated cleaning standard operating procedure based on scientific literature, official recommendations and related legislation.
188

Uso do cimento de osso alfa-tricálcio-fosfato no tratamento cirúrgico da cavidade mastóidea. Estudo experimental / Alpha-tricalcium phosphate bone cement in the surgical treatment of mastoid cavity. Experimental study

Robinson Koji Tsuji 08 September 2008 (has links)
Introdução: A mastoidectomia cavidade aberta é considerada por muitos autores o procedimento cirúrgico de escolha para o tratamento da otite média colesteatomatosa, devido à alta incidência de recidiva da doença. Porém, a formação desta cavidade única pode gerar algumas complicações e a obliteração da cavidade mastóidea é uma técnica descrita e estudada para a eliminação desta cavidade. Materiais aloplásticos têm sido estudados em cirurgias de obliteração da cavidade mastóidea, porém estes materiais podem apresentar problemas de biocompatibilidade e de rejeição O cimento de osso alfa -tricálcio-fosfato é um material composto por cálcio e fosfato e apresenta composição bioquímica semelhante à fase mineral do osso. Embora já utilizado em cirurgias há mais de 10 anos, não existem estudos sobre a sua aplicação nas cirurgias de obliteração de cavidade mastóidea na literatura. Objetivo: Estudar a biocompatibilidade do cimento de osso alfatricálcio- fosfato na obliteração da cavidade mastóidea em guinea pigs. Casuística e Métodos: Vinte Cavia porcellus (guinea pig) fêmeas foram submetidos a procedimento cirúrgico na bula timpânica esquerda. Em 10 cobaias (grupo cimento) a bula timpânica foi obliterada com o cimento de osso alfa-tricálcio-fosfato e em 10 cobaias (grupo controle) a cavidade foi deixada sem preenchimento. 60 dias após o procedimento os animais foram sacrificados e avaliados quanto à presença de sinais clínicos de rejeição ao material e outras complicações. Os ossos temporais foram removidos e submetidos à análise histopatológica. Foram avaliados o tipo e o grau de resposta inflamatória e o grau de ossificação. Resultados: A taxa de mortalidade foi igual em ambos os grupos. As mortes foram atribuídas a complicações anestésicas. Entre as cobaias que completaram o estudo não foram observados sinais de complicações em nenhum caso. Oito animais (100%) do grupo cimento em e cinco animais (62,5%) apresentaram resposta inflamatório graus I e II que correspondem histopatologicamente a alterações cicatriciais normais ao procedimento cirúrgico. Não foi observado presença de reação inflamatória crônica tipo corpo estranho em nenhuma amostra de ambos os grupos. Quanto ao grau de ossificação, a média dos escores de ossificação no grupo controle (3,5) foi maior que o observado no grupo cimento (1,0). O grupo controle (3,5 ± 5) apresentou grau de ossificação estatisticamente maior quando comparado com o grupo cimento (1,0 ± 0,0) (p < 0,01). Conclusões: 1) O cimento de osso alfa-tricálciofosfato é biocompatível em osso temporal de cobaia. 2) O cimento de osso alfa-tricálcio-fosfato sofre remodelação óssea, porém não apresenta propriedade de osteocondução / Introduction: Many authors consider open cavity mastoidectomy the surgical procedure of choice for the treatment of otitis media with cholesteatoma, due to the high incidence of recurrence of the disease. However, the formation of this open cavity can generate some complications and mastoid cavity obliteration is one type of technique for the elimination of this cavity. Alloplastic materials have been testes in mastoid cavity obliteration, however such materials can present problems of biocompatibility and rejection. Alphatricalcium phosphate bone cement is a material compose of calcium and phosphate and presents physicochemical characteristics similar to the bone mineral fase. Although it has been used for more than 10 years, there are no studies in the literature on its application in mastoid cavity obliteration. Objective: This study aimed to evaluate the biocompatibility of alphatricalcium phosphate bone cement in the obliteration of the mastoid cavity in guinea pigs. Methods: We studied 20 Cavia porcellus (guinea pig) submitted to surgical manipulation of the left dorsal tympanic bulla. In the study group animals (n = 10), mastoid cavity obliteration was conducted with alphatricalcium phosphate bone cement. In the control group animals (n = 10), the cavity was left unfilled. On postoperative day 60, the animals were sacrificed and studied for signs of rejection of the material and other complications. Temporal bones were removed for histopathological study, in which the type and degree of inflammatory response, as well as the degree of ossification, were analyzed. Results: The mortality rate was the same in both groups. Deaths were attributed to anesthetic complications in the initial postoperative period. In the animals that survived, there were no complications. The histological analysis of the degree and type of inflammatory response shown no signs of foreign body in both groups, 8 (100%) of the samples in cement group and 5 (62,5%) of the samples in control group presenting category I or II inflammatory responses that corresponds histopathologically to an inflammatory response that normally occurs in tissues submitted to surgical trauma. There were no histopathological signs of foreign body reaction in none samples of both groups. As for the study of the degree of ossification, the mean ossification in the control group (3.5) was greater than that shown by the cement group (1.0). The control group showed statistically significant (p < 0.01) higher degrees of ossification (mean 3.5 ± 0.5) when compared to the cement group (1.0 ± 0.0). Conclusion: 1) Alpha-tricalcium phosphate bone cement is biocompatible in the mastoid cavity of guinea pigs 2) Alphatricalcium fosfato bone cement undergoes bone remodeling but it doesn´t present osteoconductive properties
189

Aloenxertos ósseos e enxerto sintético de hidroxiapatita em falha óssea ulnar em galinhas (Gallus gallus domesticus)

Schmitt, Bernardo January 2018 (has links)
A utilização de enxertos ósseos vem aumentando bastante em pequenos animais, entretanto, em aves esta utilização é menor devido à dificuldade de conseguir autoenxerto em quantidades adequadas. Sendo assim, o objetivo do projeto foi avaliar três tipos de enxertos em aves. Foram utilizadas 30 galinhas separadas em três grupos: grupo aloenxerto congelado em ultrafreezer (GUF) por duas semanas; grupo aloenxerto congelado em nitrogênio líquido (GNL) e grupo enxerto sintético de hidroxiapatita deficiente em cálcio (GHA). Os enxertos foram aplicados em defeito ósseo de aproximadamente 20mm na ulna das aves e fixados ao leito receptor com uma placa e quatro parafusos bloqueados. Os animais foram acompanhados por meio de avaliação clínica, radiográfica, histológica e biomecânica. A consolidação radiográfica ocorreu em 90% nos animais do GNL, 70% nos do GUF e 60% nos do GHA, com média de 47,14±13,50 dias no GUF, 61,67±21,79 dias no GNL e aos 70±18,17 dias no GHA, havendo diferença significativa entre o GUF e GHA. Histologicamente os enxertos do GUF apresentavam-se em processo de consolidação mais avançada, com remodelação óssea e a presença de osteoclastos. Na avaliação clínica todas as ulnas operadas tinham estabilidade, sem sinal de inflamação/contaminação, articulações preservadas, sem dor e sem desvios angulares graves na asa. Na análise biomecânica houve diferença significativa (p<0,05) entre o GNL e o GHA na resistência, já na avaliação de flexão máxima, observou-se diferença estatística entre o GHA e o GNL e entre o GHA e o GUF. Sendo assim, é possível concluir que os três enxertos testados podem ser utilizados em defeitos ósseos em aves, mas o melhor deles foi o GNL por apresentar mais vantagens na preparação, confecção, aplicação dos enxertos e resistência biomecânica, com maior taxa de consolidação óssea. / The use of bone grafts is increasing considerably in small animals, however, in poultry this use is less due to the difficulty of obtaining autograft in adequate quantities. Therefore, the objective of the project was to test three types of grafts, evaluating their best results over a period of 90 days. For this purpose, 30 chickens were divided into three groups: frozen ultra freezer allograft group (UFG) for two weeks; allograft frozen in liquid nitrogen group (LNG) and synthetic grafts of calcium deficient hydroxyapatite group (HAG). Grafts were applied to a bone defect of approximately 20 mm in the ulna of birds, in all three groups the grafts were fixed to the recipient bed with plates blocked and 4 screws locked. The animals were followed up by serial radiographs, histological examination, clinical orthopedic evaluation and biomechanical flexion assay. Radiographic consolidation occurred in 90% of the LNG, 70% in the GUF and 60% in the GHA, mean of 47.14 ± 13.50 days without UFG, 61.67 ± 21.79 days non LNG and at 70 ± 18.17 days without HAG, with a significant difference between UFG and HAG. Histologically, UFG grafts were in a more advanced consolidation process, presenting bone remodeling with a presence of osteoclasts In the clinical review, all of them were operated with stability, with no sign of inflammation / contamination, preserved joints, no pain and no angular deviations, graves in the nail. In the biomechanics, there was a significant difference (p <0.05) between LNG and HAG in the resistance, already in the evaluation of maximum flexion, it was observed statistical difference not HAG with LNG and HAG with UFG grafts. Thus, it is possible to conclude that the three grafts tested are feasible to be used in bone loss in birds, where the LNG was superior because it presented more advantages in the preparation, preparation and application of the grafts, presenting a higher rate of bone consolidation.
190

A utilização da proteína morgogenética óssea recombinante humana 2 com carreadores adicionais: análise histomorfométrica e por microtomografia computadorizada 3D / The use of the human recombinant bone morphogenetic protein 2 with additional carriers: Histomorphometric and 3D Micro-computed tomography analysis

Polo, Cristiane Ibanhes 12 December 2013 (has links)
A utilização de osteoindutores como a proteína morfogenética óssea recombinante humana tipo 2 (rhBMP-2) em cirurgia oral e maxilofacial para reparação e regeneração óssea tem aumentado progressivamente. Porém, suas indicações ainda estão limitadas a preenchimento de cavidades e pequenas reconstruções. Este estudo teve como objetivo analisar e comparar, por meio da microtomografia computadorizada tridimensional (Micro-TC 3D) e histomorfometria, a arquitetura óssea, a taxa de osso neoformado e a taxa de biodegradação do -Tricálcio Fostato (-TCP), Fosfato de Cálcio Bifásico (BCP) e Osso Mineral Bovino (BBM), utilizados como carreadores adicionais à rhBMP-2/esponja de colágeno (ACS) em um modelo de regeneração óssea guiada (ROG) vertical em calvária de coelhos. Quatro cilindros de titânio foram fixados à calvária de 20 coelhos da raça Nova Zelândia. No Grupo 1 (n = 10), 3 cilindros foram aleatoriamente preenchidos com um dos materiais teste utilizados como carreadores e um cilindro foi preenchido com coágulo sanguíneo (CO). No Grupo 2 (n = 10), os cilindros foram aleatoriamente designados para os mesmos materiais e coágulo sanguíneo, com a adição da rhBMP-2/ACS. Após 14 semanas de reparação, as amostras foram coletadas e enviadas para a aquisição de imagens da Micro-TC e processamento histológico. De acordo com a análise histomorfométrica, a área óssea média para o Grupo 2 (com rhBMP-2) foi maior do que no Grupo 1 (sem rhBMP-2) para os materiais BCP e -TCP (p <0,001). Não houve diferença entre os grupos para BBM e CO (p> 0,05). Em relação às taxas de reabsorção, a área média dos materiais remanescentes no Grupo 2 foi menor do que no Grupo 1 para todos os materiais (p <0,001) e BBM e -TCP obtiveram a maior taxa de reabsorção nos dois grupos (BBM = -TCP > BCP). A análise da micro-TC revelou que no Grupo 2, BCP e -TCP apresentaram maior volume ósseo médio (BV) do que no Grupo 1 (p <0,05). Não houve diferença entre os grupos para os materiais BBM e CO (p> 0,05). O volume médio de materiais restantes (MV) para o Grupo 2 foi menor do que no Grupo 1 para BBM e -TCP (p <0,05), sem diferença significante entre os grupos para BCP (p = 0,848). A análise dos parâmetros Fator Padrão Trabecular (Tb.Pf) e Índice de Modelo Estrutural (SMI) mostrou no Grupo 2 valores negativos para BCP e -TCP, indicando melhor interconectividade e presença de arquitetura trabecular mais achatada e côncava, indicadores de melhor qualidade e resistência óssea. Pelos resultados apresentados concluiu-se que a utilização da rhBMP-2/ACS associada aos materiais carreadores BCP (Fosfato de Cálcio Bifásico) e -TCP (-Fosfato Tricálcio) aumentou significativamente a formação óssea neste modelo de ROG em calvária de coelhos além de acelerar a biodegradação dos materiais BBM (Osso Mineral Bovino) e -TCP (-Fosfato Tricálcio) neste modelo de ROG. / The use of osteoinductors as the human recombinant bone morphogenetic protein 2 type 2 (rhBMP-2) in oral and maxillofacial surgery for bone regeneration and repair has progressively increased. However, indications are still limited to filling of cavities and small reconstructions. However, its indications are still limited to filling of cavities and small reconstructions. This study aimed to analyze and compare, by means of three-dimensional microtomography (Micro-CT 3D) and histomorphometry, the bone architecture, the rate of newly formed bone and the biodegradation rate of beta tricalcium phosphate (-TCP), biphasic calcium phosphate (BCP), and mineral bovine bone mineral (BBM) used as additional carriers to rhBMP-2/absorbable collagen sponge (ACS) in a vertical guided bone regeneration model (GBR) in rabbit calvarium. Four titanium cylinders were fixed to the calvarium of 22 New Zealand rabbits. In Group 1 (n = 10), 3 cylinders were randomly filled with one of the test materials and 1 cylinder was filled with a blood clot (CL). In Group 2 (n = 10), the cylinders were randomly assigned to the same materials and blood clot, with the addition of rhBMP-2. After 14 weeks of healing the samples were collected and sent to 3D Micro-CT image acquisition and histological processing. According to histomorphometric analysis, the mean bone area in Group 2 (with rhBMP-2) was greater than in Group 1 (without rhBMP-2) to materials BCP and -TCP (p<0.001). There was no difference between groups to BBM and CL (p>0.05). Regarding the resorption rates, the mean area of remaining materials in Group 2 was lower than in Group 1 to all materials (p<0.001) and BBM and -TCP had the greater resorption rate in both groups (BBM= -TCP >BCP). The Micro-CT analysis revealed that in Group 2, BCP and -TCP had greater mean bone volume (BV) than in Group 1 (p<0.05). There was no difference between groups to materials BBM and CL (p>0.05). The mean volume of remaining materials (MV) in Group 2 was lower than in Group 1 to BBM and -TCP (p<0.05). There was no difference between groups to BC (p=0.848). The analysis of the parameters Trabecular Pattern Factor (Tb.Pf) and Structure Model Índex (SMI), in Group 2 showed negative values for BCP and -TCP, indicating better interconnectivity and presence of more plate-like and trabecular architecture more flattened and concave, indicators of better quality and bone strength. By presented results it was concluded that the use of rhBMP-2/ACS associated with the carriers materials biphasic calcium phosphate (BCP) and beta tricalcium phosphate (-TCP) used as additional carriers, significantly increased bone formation in addition to accelerate the resorption of the materials BO (bovine bone mineral) and -TCP in this guided bone regeneration model in rabbit calvaria.

Page generated in 0.045 seconds