Spelling suggestions: "subject:"biocompatíveis"" "subject:"citocompatíveis""
201 |
A utilização da proteína morgogenética óssea recombinante humana 2 com carreadores adicionais: análise histomorfométrica e por microtomografia computadorizada 3D / The use of the human recombinant bone morphogenetic protein 2 with additional carriers: Histomorphometric and 3D Micro-computed tomography analysisCristiane Ibanhes Polo 12 December 2013 (has links)
A utilização de osteoindutores como a proteína morfogenética óssea recombinante humana tipo 2 (rhBMP-2) em cirurgia oral e maxilofacial para reparação e regeneração óssea tem aumentado progressivamente. Porém, suas indicações ainda estão limitadas a preenchimento de cavidades e pequenas reconstruções. Este estudo teve como objetivo analisar e comparar, por meio da microtomografia computadorizada tridimensional (Micro-TC 3D) e histomorfometria, a arquitetura óssea, a taxa de osso neoformado e a taxa de biodegradação do -Tricálcio Fostato (-TCP), Fosfato de Cálcio Bifásico (BCP) e Osso Mineral Bovino (BBM), utilizados como carreadores adicionais à rhBMP-2/esponja de colágeno (ACS) em um modelo de regeneração óssea guiada (ROG) vertical em calvária de coelhos. Quatro cilindros de titânio foram fixados à calvária de 20 coelhos da raça Nova Zelândia. No Grupo 1 (n = 10), 3 cilindros foram aleatoriamente preenchidos com um dos materiais teste utilizados como carreadores e um cilindro foi preenchido com coágulo sanguíneo (CO). No Grupo 2 (n = 10), os cilindros foram aleatoriamente designados para os mesmos materiais e coágulo sanguíneo, com a adição da rhBMP-2/ACS. Após 14 semanas de reparação, as amostras foram coletadas e enviadas para a aquisição de imagens da Micro-TC e processamento histológico. De acordo com a análise histomorfométrica, a área óssea média para o Grupo 2 (com rhBMP-2) foi maior do que no Grupo 1 (sem rhBMP-2) para os materiais BCP e -TCP (p <0,001). Não houve diferença entre os grupos para BBM e CO (p> 0,05). Em relação às taxas de reabsorção, a área média dos materiais remanescentes no Grupo 2 foi menor do que no Grupo 1 para todos os materiais (p <0,001) e BBM e -TCP obtiveram a maior taxa de reabsorção nos dois grupos (BBM = -TCP > BCP). A análise da micro-TC revelou que no Grupo 2, BCP e -TCP apresentaram maior volume ósseo médio (BV) do que no Grupo 1 (p <0,05). Não houve diferença entre os grupos para os materiais BBM e CO (p> 0,05). O volume médio de materiais restantes (MV) para o Grupo 2 foi menor do que no Grupo 1 para BBM e -TCP (p <0,05), sem diferença significante entre os grupos para BCP (p = 0,848). A análise dos parâmetros Fator Padrão Trabecular (Tb.Pf) e Índice de Modelo Estrutural (SMI) mostrou no Grupo 2 valores negativos para BCP e -TCP, indicando melhor interconectividade e presença de arquitetura trabecular mais achatada e côncava, indicadores de melhor qualidade e resistência óssea. Pelos resultados apresentados concluiu-se que a utilização da rhBMP-2/ACS associada aos materiais carreadores BCP (Fosfato de Cálcio Bifásico) e -TCP (-Fosfato Tricálcio) aumentou significativamente a formação óssea neste modelo de ROG em calvária de coelhos além de acelerar a biodegradação dos materiais BBM (Osso Mineral Bovino) e -TCP (-Fosfato Tricálcio) neste modelo de ROG. / The use of osteoinductors as the human recombinant bone morphogenetic protein 2 type 2 (rhBMP-2) in oral and maxillofacial surgery for bone regeneration and repair has progressively increased. However, indications are still limited to filling of cavities and small reconstructions. However, its indications are still limited to filling of cavities and small reconstructions. This study aimed to analyze and compare, by means of three-dimensional microtomography (Micro-CT 3D) and histomorphometry, the bone architecture, the rate of newly formed bone and the biodegradation rate of beta tricalcium phosphate (-TCP), biphasic calcium phosphate (BCP), and mineral bovine bone mineral (BBM) used as additional carriers to rhBMP-2/absorbable collagen sponge (ACS) in a vertical guided bone regeneration model (GBR) in rabbit calvarium. Four titanium cylinders were fixed to the calvarium of 22 New Zealand rabbits. In Group 1 (n = 10), 3 cylinders were randomly filled with one of the test materials and 1 cylinder was filled with a blood clot (CL). In Group 2 (n = 10), the cylinders were randomly assigned to the same materials and blood clot, with the addition of rhBMP-2. After 14 weeks of healing the samples were collected and sent to 3D Micro-CT image acquisition and histological processing. According to histomorphometric analysis, the mean bone area in Group 2 (with rhBMP-2) was greater than in Group 1 (without rhBMP-2) to materials BCP and -TCP (p<0.001). There was no difference between groups to BBM and CL (p>0.05). Regarding the resorption rates, the mean area of remaining materials in Group 2 was lower than in Group 1 to all materials (p<0.001) and BBM and -TCP had the greater resorption rate in both groups (BBM= -TCP >BCP). The Micro-CT analysis revealed that in Group 2, BCP and -TCP had greater mean bone volume (BV) than in Group 1 (p<0.05). There was no difference between groups to materials BBM and CL (p>0.05). The mean volume of remaining materials (MV) in Group 2 was lower than in Group 1 to BBM and -TCP (p<0.05). There was no difference between groups to BC (p=0.848). The analysis of the parameters Trabecular Pattern Factor (Tb.Pf) and Structure Model Índex (SMI), in Group 2 showed negative values for BCP and -TCP, indicating better interconnectivity and presence of more plate-like and trabecular architecture more flattened and concave, indicators of better quality and bone strength. By presented results it was concluded that the use of rhBMP-2/ACS associated with the carriers materials biphasic calcium phosphate (BCP) and beta tricalcium phosphate (-TCP) used as additional carriers, significantly increased bone formation in addition to accelerate the resorption of the materials BO (bovine bone mineral) and -TCP in this guided bone regeneration model in rabbit calvaria.
|
202 |
Síntese e caracterização de nanopartículas poliméricas para veiculação de lignanas bioativas / Synthesis and characterization of polymeric nanoparticles for bioactive lignanLima, Regiane Godoy de 20 April 2018 (has links)
Submitted by Regiane Godoy de Lima (regigodoy@gmail.com) on 2018-07-10T18:42:41Z
No. of bitstreams: 1
Tese Regiane versão final.pdf: 4431175 bytes, checksum: ae162e9e86a8dc06ab1e81dc83a8f1cd (MD5) / Approved for entry into archive by Cristina Alexandra de Godoy null (cristina@adm.feis.unesp.br) on 2018-07-10T19:18:43Z (GMT) No. of bitstreams: 1
lima_rg_dr_ilha.pdf: 4431175 bytes, checksum: ae162e9e86a8dc06ab1e81dc83a8f1cd (MD5) / Made available in DSpace on 2018-07-10T19:18:43Z (GMT). No. of bitstreams: 1
lima_rg_dr_ilha.pdf: 4431175 bytes, checksum: ae162e9e86a8dc06ab1e81dc83a8f1cd (MD5)
Previous issue date: 2018-04-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os produtos naturais são uma fonte inesgotável de compostos químicos com as mais variadas propriedades biológicas, entretanto, muitos deles têm baixa biodisponibilidade e/ou são degradados pelas condições fisiológicas, o que os torna de pouco interesse para uso como potenciais fármacos. Dentre os vários produtos naturais bioativos as lignanas apresentam um significativo potencial citotóxico contra várias linhagens de células tumorais, como a (-)-hinoquinina (HNK), (-)-cubebina (CB) e (-)-6,6’-dinitrohinoquinina (DN), determinado em outros trabalhos. Entretanto, essa lignanas possuem caráter hidrofóbico e podem ser degradadas em condições fisiológicas dependendo do pH. Desta forma, o presente trabalho teve por objetivo estudar a incorporação dessas lignanas em nanopartículas poliméricas (NNPs), como forma de melhorar a biodisponibilidade, perdas por degradação e os efeitos da incorporação sobre a atividade citotóxica desses compostos. Neste estudo a HNK e CB foram extraídas da Piper cubeba e a DN foi sintetizada a partir da reação de nitração da HNK. Essa lignanas foram submetidas a ensaios de citotoxicidade contra as linhagens tumorais Hep-2 e Si-Ha. As NNPs com e sem a lignana foram sintetizadas utilizando como matriz polimérica inicialmente o PLGA (Poli(ácido lático-co-ácido glicólico). As NNPs sintetizadas foram caracterizadas quanto ao seu tamanho, morfologia e estabilidade utilizando análises de MEV, DSC, MET, UV/Vis, FTIR, DLS e potencial zeta. A eficiência da incorporação foi determinada através de analises de UV/Vis. Nos ensaios de citotoxicidade todas as lignanas foram ativas, com destaque para a inibição de 98% da HNK sobre a linhagem Hep-2. As três lignanas foram incorporadas em NNPs de PLGA utilizando o método de nanoemulsão-evaporação com agitação mecânica e gotejamento, entretanto a estabilidade dessas NNPs e as porcentagens de incorporação indicaram que apenas as NNPs-PLGA-HNK apresentaram os parâmetros necessários para a utilização nos ensaios de citotoxicidade. Portanto, outros estudos foram realizados com as três lignanas visando a melhora nos métodos de obtenção e estabilidade com o uso de sonicador e diferente composição do PLGA (50:50) e PLGA-PEG. As análises físicas mostraram que as nanopartículas de PLGA (50:50) obtidas através da metodologia por sonicação foram mais estáveis com menores tamanhos e maior potencial zeta em valores absolutos, entretanto, a DN e a CB não foram encapsuladas de forma eficiente. Desta forma, somente a HNK prosseguiu no estudo. O uso do PLGA-PEG alterou de forma significante os parâmetros físicos e químicos das NNPs-PLGA-PEG-HNK em relação as de PLGA-HKN. Os testes de liberação mostraram melhores resultados com as NNPs-PLGA-HNK, principalmente em pH 7,4. O tempo de liberação total da HNK em todas as NNPs avaliadas foi em torno de 30 minutos o que sugere que as nanopartículas obtidas são nanocápsulas. A comparação dos resultados dos ensaios de citotoxicidade mostraram que o CI50 das NNPs de PLGA-HNK foi de 29,8 µM sobre as células tumorais Si-Ha, enquanto a HNK livre apresentou CI50 = 110 µM. Para as outras células tumorais mais agressivas as NNPs de PLGA(50:50)-HNK foram menos eficazes do que a HNK livre, com cerca de 50% de perda da atividade. Esses resultados indicam a efetividade das NPPs de PLGA(65:35)-HNK sobre as células da linhagem Si-Ha, e que o encapsulamento da HNK em NNPs de PLGA pode ser uma alternativa para diminuir a decomposição e aumentar a biodisponibilidade para a condução de em ensaios in vivo. / The natural products are inexhaustible source of chemical compounds with the most varied biological properties; however, many of them have low bioavailability and / or are degraded by physiological conditions, which makes them less interesting for use as potential drugs. Among the several bioactive natural products the lignans present a significant cytotoxic potential against several tumor cell lines, as (-)-hinokinin (HNK), (-)-cubebin (CB) and (-)-6,6’-dinitrohinokinin (DN), determined in previous works. However, these lignans have a hydrophobic character and can be degraded in physiological conditions depending on pH. Thus, the present work aimed to study the incorporation of these lignans into polymeric nanoparticles (PNPs), as a method to improve bioavailability, avoid losses by degradation and evaluate as this incorporation affects the its cytotoxic activity. In this study, the HNK and CB were extracted from Piper cubeba and the DN was synthesized from the nitration reaction of the HNK. These lignans were submitted to cytotoxicity assays against tumoral cells Hep-2 and Si-Ha. The empty and content lignans PLGA (Poly Lactic-co-Glycolic Acid, 65:35) PNPs were synthesized using the emulsion-evaporation methodology on mechanical agitation and dripping. The PNPs were investigated for their size, morphology and stability through SEM, DSC, TEM, UV/Vis, FTIR, DLS and zeta potential. Encapsulation efficiency incorporation of the lignan was determined by analysis of UV/Vis. In the cytotoxicity assays all lignans were active, with emphasis on inhibition of 98% da (-)-hinokinin about the Hep-2 tumoral line. The three lignans were incorporated into PLGA (65:35) NNPs, however the stability of these PNPs and the percentages of incorporation indicated that only the PLGA-HNK PNPs had the parameters required for use in the cytotoxicity assays. Therefore, other studies were performed with the three lignans aiming to improve the methods of obtaining and stability from sonicator and different composition in PLGA: (50:50) and PLGA-PEG. The physical analyzes showed that PLGA (50:50) nanoparticles obtained by sonication were more stable with smaller sizes and higher zeta potential in absolute values. However, even in this method, DN e CB were not efficiently encapsulated. In this way, only HNK continued the study. The use of PLGA-PEG altered the physical and chemical parameters of PLGA-PEG-HNK NNPs obtained when compared to PLGA-HNK NNPs. Release tests showed better results with NNPs-PLGA-HNK, especially at pH 7.4. The total release time of HNK in all NNPs evaluated was around 30 minutes, which suggests that the nanoparticles obtained are nanocapsules. Comparison of cytotoxicity assay results showed that PLGA-HNK PNPs IC50 was 29.8 μM on the Si-Ha tumor cells, while the free HNK showed IC50 = 110 μM. For the other more aggressive tumor cells PLGA (50:50)-HNK PNPs were less effective than free HNK with about 50% loss of activity. These results indicate the effectiveness of PLGA(65:35)-HNK NPPs on cells of the Si-Ha line, and that the encapsulation of HNK in PLGA NNPs may be an alternative to decrease decomposition and increase bioavailability for conducting biological assays in vivo. / PSDE/88881.134923/2016-01
|
203 |
Avaliação da biocompatibilidade e citotoxicidade dos cimentos: Endo-CPM-Sealer, Sealapex e Ângelus MTAWatanabe, Simone [UNESP] 19 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:46Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-12-19Bitstream added on 2014-06-13T18:56:29Z : No. of bitstreams: 1
watanabe_s_me_araca.pdf: 310690 bytes, checksum: cd933b6e1170509831a34ff5afc29200 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A necessidade de melhorar a qualidade dos materiais utilizados no tratamento endodôntico tem estimulado o estudo de vários materiais, buscando melhores condições de trabalho, biocompatibilidade e propriedade de estimular a ocorrência do selamento biológico. Este trabalho teve a finalidade de avaliar quantitativamente e qualitativamente a resposta tecidual frente ao implante de tubos de polietileno preenchidos pelos cimentos Endo-CPM-Sealer®, Sealapex® e Ângelus MTA® em tecido subcutâneo de ratos e a citotoxicidade e a produção de citocinas (IL-1β e IL-6) por fibroblastos de camundongos estimulados por estes cimentos. Para os testes de biocompatibilidade foram utilizados 30 ratos, os quais receberam individualmente três implantes de tubos de polietileno contendo os cimentos a serem testados e mais um tubo vazio como controle. Após 7, 15, 30, 60 e 90 dias do período de implantação, os animais foram sacrificados e os tubos de polietileno juntamente com o tecido que o circunda foram removidos, fixados e processados para análise em microscopia de luz. Após inclusão em glicol metacrilato, foram realizados cortes seriados de 3mm, corados com hematoxilina-eosina e cortes de 10mm, corados com Von Kossa e sem coloração para serem analisados sob luz polarizada. Os resultados foram analisados estatisticamente pelo teste de Kruskal Wallis. Os materiais Endo-CPM-Sealer®, Sealapex® e Ângelus MTA® causaram reações moderada no tempo experimental de 7 dias que diminuiu com o tempo. A resposta foi similar entre os grupos Controle, Endo- CPM-Sealer® e Ângelus MTA® no tempo experimental de 30 dias. Aos 60 dias todos os grupos foram semelhantes ao Controle. Mineralizações e granulações birrefringentes à luz polarizada foram observadas com todos os materiais. Foi possível concluir que o Endo-CPM-Sealer® foi biocompatível e estimulou a mineralização. Para o teste... / The need of improving the quality of materials used in endodontic treatment has stimulated the study of various materials seeking better working conditions, biocompatibility and property to stimulate the occurrence of biological sealing. The aim of this study was to evaluate quantitatively and qualitatively the tissue response to the implantation of polyethylene tubes filled with Endo-CPM-Sealer®, Sealapex® and Ângelus MTA® in subcutaneous tissue of rats and cytotoxicity and production of cytokines (IL-1β and IL-6) by mouse fibroblasts stimulated by these sealers. Thirty rats were used for the biocompatibility tests. Each animal received three implants of polyethylene tubes containing the cement to be tested and one empty polyethylene tube was used as control. After 7, 15, 30, 60 and 90 days from the implantation time, the animals were killed and the tubes with surrounding tissues were removed, fixed and processed for analysis using a light microscope. After inclusion in glycol methacrylate, they were serially sectioned into 3 μm or 10 μm cuts and stained with hematoxylineosin, Von Kossa or remained without staining to be observed under polarized light. The results were statistically analyzed by Kruskal Wallis test. The materials Endo- CPM-Sealer®, Sealapex® and Ângelus MTA® caused moderate reactions at 7 days which decreased with time. The response was similar among the control group, Endo- CPM-Sealer® and Ângelus MTA® at the 30th day. At 60th day all groups were similar to control group. Mineralization and granulations birefringent to the polarized light were observed with all materials. It was possible to conclude that Endo-CPM-Sealer® was biocompatible and stimulated mineralization. To test the cytotoxicity of mouse fibroblast (L929) were incubated in plate of 24 wells and stimulated with the sealers tested. Cell culture... (Complete abstract click electronic access below)
|
204 |
Análise comparativa de diferentes substitutos ósseos sintéticos microporosos em calvária de coelhos / Comparative analysis of different Synthetic microporous bone substitutes in rabbit calvariaLevandowski Junior, Nelson 14 July 2014 (has links)
Made available in DSpace on 2016-12-08T15:56:17Z (GMT). No. of bitstreams: 1
Resumo LEVANDOWSKI.pdf: 475369 bytes, checksum: 6234f28eabf60dbad017c95e2d659f76 (MD5)
Previous issue date: 2014-07-14 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Nanotechnology involves creation, manipulation and exploitation of materials at the nanoscale. This Science has led to research and development of new materials consisting of molecules, particles and/or grains in the nanometer scale. The Research Group in Biomaterials of UDESC develops studies in the field of nanotechnology and nanomaterials for more than a decade with the goal of developing nanostructured biomaterials with different characteristics of conventional biomaterials, capable of promoting early bone formation and contributes significantly within the bone healing and quality of life The first step of this Thesis research aimed to characterize six different granular microporous biomaterials divided into two groups. Group I was composed of hydroxyapatite (HAp), beta tricalcium phosphate (TCP), and biphasic calcium phosphate (BCP) at a concentration of 60% HAp and 40% TCP by volume. Group II consisted of three compositions of nanocomposites in hydroxyapatite matrix, with 5% by volume of the second nanometric phase, in the following compositions: HAp-SiO2n, HAp-TiO2n and HAp-Al2O3-αn. The results of the characterization were related to X-ray diffraction analysis (XRD), Fourier transformed infrared spectroscopy (FTIR), morphological and microstructural characterization, specific surface area, hydrostatic density and open porosity. After characterization studies, the calcium phosphate biomaterials and nanocomposites were used for simultaneous comparative analysis of bone formation in a method of guided bone augmentation in rabbit calvaria. Blood clot (C) and bovine hydroxyapatite BioOss® (HAP-BOV) served as control. The results of histomorphometric analysis demonstrated that the biomaterial HAp-SiO2 showed the highest amount of mineralized bone tissue after 45 days (39.07%), followed by HAp (36.92%), TCP (31.3%), BCP (31.2%), HAp-Al2O3 (28.88%), HAp-BOV (26.45%), HAp-TiO2 (15.92%) and C (3.6%). After 90 days, analysis was performed only for Group I and the 14 HAp biomaterial had the highest amount of mineralized bone tissue (49.46%), followed by BCP (41.5%), TCP (35.18%) and C (6.26%). The results of the characterization and in vivo studies showed that calcium phosphates HAp, TCP, BCP and nanocomposite HAp-SiO2 were biocompatible and do not induced inflammatory tissue reactions. Their microstructural characteristics, with lower grain than 800nm and interconnected microporosity above 25%, provided better performance of bone formation in relation to commercial biomaterial used as control. / A nanotecnologia envolve a criação, manipulação e exploração de materiais na escala nanométrica. Esta Ciência tem levado à investigação e ao desenvolvimento de novos materiais constituídos por moléculas, partículas e/ou grãos na escala do nanômetro. O Grupo de Pesquisa em Biomateriais da UDESC desenvolve pesquisas na área de nanotecnologia e nanomateriais há mais de uma década com o objetivo de desenvolver biomateriais nanoestruturados com características diferenciadas dos biomateriais convencionais, capazes de promover a neoformação óssea precoce e contribuir significativamente dentro dos processos de reparação tecidual e com a qualidade de vida. A primeira etapa deste trabalho de Tese teve por objetivo realizar a caracterização de seis diferentes biomateriais microporosos granulados, divididos em dois grupos. O grupo I foi composto pelos biomateriais hidroxiapatita (HAp), fosfato tricálcico beta (TCP) e fosfato de cálcio bifásico (BCP) na concentração de 60% HAp e 40% TCP em volume. O grupo II foi formado por três composições de biomateriais nanocompósitos em matriz de hidroxiapatita, a 5% em volume da segunda fase nanométrica, nas seguintes composições: HAp-SiO2n, HAp-TiO2n e HAp-Al2O3-n. Os resultados de caracterização obtidos relacionaram os dados referentes à análise por difratometria de raios X (DRX), espectroscopia de infravermelho com transformada de Fourier (FTIR), caracterização morfológica e microestrutural, área superficial, densidade hidrostática e porosidade aberta. Após a realização dos estudos de caracterização, os biomateriais fosfatos de cálcio e nanocompósitos foram utilizados para uma análise comparativa simultânea de formação óssea em um método de aumento ósseo guiado em calvária de coelhos. Como controle foram utilizados o coágulo sanguíneo (C) e a hidroxiapatita bovina BioOss® (HAP-BOV). Os resultados da análise histomorfométrica demonstraram que o biomaterial HAp-SiO2 apresentou a maior quantidade de tecido ósseo mineralizado aos 45 dias (39,07%), seguido da HAp (36,92%), TCP (31,3%), BCP (31,2%), HAp-Al2O3 (28,88%), HAp-BOV (26,45%), HAp-TiO2 (15,92%) e C (3,6%). A análise aos 90 dias foi realizada apenas para o grupo I e o biomaterial HAp apresentou a maior 12 quantidade de tecido ósseo mineralizado (49,46%), seguido por BCP (41,5%), TCP (35,18%) e C (6,26%). Os resultados obtidos dos estudos de caracterização e de formação óssea mostraram que os fosfatos de cálcio microporosos HAp, TCP, BCP e o nanocompósito microporoso HAp-SiO2 foram biocompatíveis e não induziram reações teciduais inflamatórias. Suas características microestruturais, com grãos inferiores a 800nm e microporosidade interconectada acima de 25%, proporcionaram um melhor desempenho de formação óssea em relação ao biomaterial comercial utilizado como controle.
|
205 |
Avaliação inflatória da associação da clorexidina com o hipoclorito de sódio em tecido conjuntivo de rato / Evaluation of inflammatory chlorhexidine with sodium hypochlorite irrigants in rat connective tissueGuilherme Henrique Rosa Martins 24 September 2013 (has links)
A associação dos irrigantes endodônticos hipoclorito de sódio e clorexidina forma um precipitado amarronzado e subprodutos que podem ser tóxicos aos tecidos periodontais apicais. O objetivo deste trabalho foi de avaliar qualitativamente e quantitativamente a resposta inflamatória destes irrigantes e suas associações em tecido conjuntivo no dorso do rato. Foram utilizados 24 ratos machos Wistar, 220 gr, cuja região dorsal foram confeccionadas quatro feridas cirúrgicas por punch de 08mm que receberam 20 mL dos irrigantes endodônticos, sendo divididos em: soro fisiológico, solução de digluconato de clorexidina a 2%, hipoclorito de sódio a 1% e a 2,5%, mistura de 10mL de hipoclorito de sódio a 1% mais 10mL de clorexidina a 2% e mistura de 10mL de hipoclorito de sódio a 2,5% mais 10mL de clorexidina a 2%. O experimento foi realizado em triplicata e os animais foram sacrificados nos tempos experimentais de 0 (imediato), 24h, 72h e 168h. Os fragmentos foram fixados e corados com hematoxilina e eosina para análise histomorfológica. Para a quantificação celular, cortes histológicos dos grupos de 24, 72 e 168h foram tratados para serem imunomarcados pelos anticorpos para linfócitos CD4 e CD8, e Anti pan-macrófago para marcação de macrófagos. Foram tomadas três fotografias num aumento de 400x de cada lâmina, para serem quantificadas através do software ImageJ. Os dados foram tabulados e submetidos ao teste estatístico ANOVA (dois critérios), com pós-teste de Bonferroni (=0,05), comparando os grupos em função dos marcadores, tempos experimentais e grupos testados. Os resultados obtidos na análise microscópica puderam identificar variações significativas entre os grupos estudados e o controle. Enquanto que no controle não foi verificado um grau de inflamação elevado, nos grupos testados foram observados destruição tecidual, aumento de número e tamanho de vasos, infiltrado inflamatório intenso, edema e início de epitelização até 168h. Na análise quantitativa, foi observado um pico celular em 72h para todos os marcadores (p<0,001). Todos os grupos testados apresentaram níveis celulares maiores que o grupo do soro fisiológico (p<0,001), exceto para o marcador de macrófagos (p>0,05). As associações das substâncias em comparação com as substâncias isoladas não apresentaram diferenças significantes (p>0,05), exceto em 72h no marcador CD4 e com hipoclorito de sódio a 2,5% (p<0,001). Estes resultados foram similares tanto para os grupos individuais bem como nas associações. Pode-se concluir, do ponto de vista biológico, que a associação entre o hipoclorito de sódio e a clorexidina mostraram resposta inflamatória semelhante as substâncias isoladas e que podem ser empregados na terapia endodôntica. / The association of endodontic irrigants sodium hypochlorite and chlorhexidine results in the formation of a brownish precipitate and its byproducts can be toxic to the periodontal tissue. The aim of this study was to evaluate qualitatively and quantitatively the inflammatory response of these drugs and their associations in the connective tissue on the back of the mouse. Four dorsal surgical wounds made by 08mm punch in twenty four male Wistar rats of 220 gr received 20 mL of each endodontic irrigants and were divided into grupos: saline solution, 2% chlorhexidine digluconate, 1% and 2,5% sodium hypochlorite, mixture of 10 ml of 1% sodium hypochlorite plus 10 ml of 2% chlorhexidine and mixture of 10 ml of 2,5% sodium hypochlorite plus 10 ml of 2% chlorhexidine. The test was performed in triplicate, the animals sacrificed at 0h (immediately), 24h, 72h and 168h and the fragments fixed, stained with hematoxylin and eosin for histomorphological analysis. To quantify cells, histological sections from 24, 72 and 168h groups were treated and immunostained by CD4, CD8 lymphocytes and Anti-pan macrophage antibodies. Three pictures were taken in a 400x magnification of each slide and quantified using the ImageJ software. Data was tabulated and submitted to ANOVA (two-way) with Bonferroni post-test (=0.05) comparing the markers, times and experimental groups. The results obtained in the microscopic analysis identified significant differences among the experimental and control groups. In control group there was not high degree of inflammation; in the experimental groups there were tissue destruction, number and size of vessels increased, intense inflammatory infiltration, edema and early epithelialization at 168h. In the quantitative analysis a peak of all cell markers was observed at 72h (p<0.001). All experimental groups showed higher cellular levels than the saline group (p<0.001) except for the macrophages marker groups (p>0.05). The associated or isolated use of the substances showed no significant differences (p> 0.05) except for 72h CD4 marker and with 2.5% sodium hypochlorite group (p<0.001). The results were similar for both individuals and associated groups. In conclusion the association between sodium hypochlorite and chlorhexidine showed inflammatory process similar to isolated substances and therefore it can be utilized in endodontic therapy.
|
206 |
Mecanismos envolvidos na resposta imune e inflamatória frente à implantação de membrana de cortical óssea bovina no tecido subcutâneo de camundongos: caracterização histomorfométrica, imunoenzimática e molecular / Mechanisms involved in immune and inflammatory response to implantation of bovine bone cortical membrane in subcutaneous tissue of mice: characterization histomorphometric, imunoenzimatic and molecularElcia Maria Varize Silveira 19 June 2012 (has links)
Os avanços relacionados à ciência dos biomateriais e engenharia tecidual buscam esclarecer os mecanismos envolvidos na resposta biológica associada ao uso desses dispositivos e sua interação com o sistema imune. Neste estudo, avaliou-se a resposta imune e inflamatória desenvolvida em camundongos frente à implantação de membrana de cortical óssea bovina no tecido subcutâneo, em implantação única e sequencial de duas membranas, assim como os possíveis mecanismos envolvidos no processo de reconhecimento e reabsorção desse biomaterial, de acordo com análise histomorfométrica, enzimática e molecular. Após a implantação da membrana, sinais de reabsorção que antes eram notados em pontos isolados, aos poucos se unem até sua completa degradação, observada somente após 15 dias. Todo o processo de reabsorção da membrana é acompanhado por uma reação inflamatória de magnitude moderada, seguida pelo declínio do número de leucócitos, surgimento de células gigantes multinucleadas e formação de uma cápsula de tecido conjuntivo fibroso. A cinética de TNF- e MMP-2, MMP-8, MMP-9 e MMP-13 apresentou um padrão de produção decrescente, entretanto os níveis dos inibidores de metaloproteinases (TIMPs) e TGF- parecem atuar de forma inversa. A velocidade de reabsorção após duas implantações consecutivas da membrana foi maior quando comparada ao grupo de animais que sofreu apenas uma implantação, porém os resultados do teste de hipersensibilidade do tipo tardia (DTH) demonstraram que a membrana é biocompatível, pois não elicitou resposta imunológica exacerbada após uma segunda implantação, confirmando então a natureza não imunogênica desse biomaterial. Finalmente, os animais CD14KO e MyD88KO apresentaram uma reabsorção mais lenta da membrana implantada, quando comparados aos animais C57Bl/6 (WT), demonstrando que as moléculas CD14 e MyD88 estão envolvidas no reconhecimento do biomaterial e desempenham importante papel no processo de reabsorção da membrana de cortical óssea bovina, indicando a participação de PAMPs e/ou DAMPs na resposta biológica gerada por esse biomaterial. / Advances related to the biomaterials science and tissue engineering seek to clarify the mechanisms involved in the biological response associated with the use of those devices and their interaction with the immune system. This study evaluated the inflammatory and immune response developed in mice after implantation bovine bone cortical membrane in subcutaneous tissue, in both, unique and sequential implantation of 2 membranes, as the mechanisms involved in this biomaterial recognition and resorption process, on regards to histomorphometric, enzymatic and molecular analysis. After membrane implantation, previously observed signs of resorption in isolated spots, gradually unite until their complete degradation after 15 days. The whole membrane resorption process is accompanied by a moderate inflammatory reaction, followed by a decline in the leukocytes number, appearance of multinucleated giant cells and formation of a capsule of fibrous connective tissue. The kinetics of TNF-, MMP-2, MMP-8, MMP-9 e MMP-13 showed a pattern of decreasing production, however, levels of metalloproteinases inhibitors (TIMPs) and TGF- seem to act in reverse way. The resorption rate after two successive membrane implantations was higher when compared to the group which suffered only one implantation, however, the results of delayed test hypersensity (DTH) demonstrated that the membrane is biocompatible, that is, it does not elicited too high immune response after a second position, confirming the non immunogenic nature of this biomaterial. Eventually, CD14KO and MyD88KO strains showed a slower membrane resorption when compared to animals C57Bl/6, demonstrating that the CD14 and MyD88 molecules are involved in biomaterial recognition and play an important role in bovine cortical bone membrane resorption process, indicating that PAMPs and/or DAMPs are involved in biological response generated by this biomaterial.
|
207 |
Avaliação comparativa da neoformação óssea após enxertia de HA/TCPp, Bio-Oss e osso autógeno associados ou não ao PRP em cirurgias de levantamento de seio maxilar de coelhos / Comparative evaluation of new bone formation after grafting with HA/TCPp, Bio-Oss and autogenous bone associated or not with PRP in maxillary sinus lift surgeries in rabbitsCaroline Andrade Rocha 14 September 2015 (has links)
O objetivo da presente pesquisa foi investigar o ganho e a qualidade óssea promovidos com a utilização da cerâmica bifásica HA/TCPp porosa comparativamente ao enxerto ósseo autógeno e ao Bio-Oss® associados ou não ao plasma rico em plaquetas (PRP), em cirurgias de levantamento de seio maxilar em coelhos. Em 54 coelhos foram realizados levantamento bilateral dos seios, sendo um dos seios preenchido com enxerto/biomaterial e sangue (SG) e o contralateral com o enxerto/biomaterial e PRP, e os grupos de tratamento designados de HA/TCPp/SG, HA/TCPp/PRP, AUT/SG, AUT/PRP, Bio-Oss/SG e Bio-Oss/PRP. Após os períodos de 30, 60 e 180 dias (n=18/período), as peças histológicas foram coletadas e fixadas em formol a 10% tamponado. Em seguida, imagens microtomográficas foram obtidas e as peças processadas histologicamente. O volume e altura do seio maxilar elevado foram determinados nas imagens microtomográficas e o percentual e volume do biomaterial e tecido ósseo avaliados nos cortes histológicos pela técnica morfométrica de volumetria de pontos. Os dados foram comparados pela ANOVA a três critérios e as médias contrastadas pelo teste de Tukey, com nível de significância de 5%. O volume e altura do seio maxilar elevado se mantiveram estáveis nos grupos Bio-Oss e HA/TCP, com valores médios de, respectivamente, 154,9mm3 e 5,6mm entre 30 e 180 dias, enquanto que, no grupo AUT essas mesmas dimensões reduziram, respectivamente, 33,3% e 21,7%. O enxerto autógeno sofreu rápida reabsorção e promoveu concomitantemente intensa neoformação/remodelação óssea até os 60 dias. Entre 60 e 180 dias o volume ósseo ganho não se manteve, reduzindo 52,5%. A associação do enxerto AUT com PRP acelerou o processo de neoformação/remodelação óssea e a reabsorção osteoclástica das partículas enxertadas. Já o volume do Bio-Oss® e HA/TCP, praticamente não se modificou em todo período e a formação óssea ocorreu nos espaços entre as partículas, ocupando um volume em média de 42,85mm3 aos 60 dias, que se manteve até os 180 dias. A adição do PRP aos biomateriais Bio-Oss® e HA/TCPp não promoveu alterações na quantidade de tecido ósseo neoformado, porém acelerou o seu processo de maturação, em relação aos grupos associados com SG. Os três materiais aqui usados no levantamento de seio maxilar, permitiram uma expressiva formação óssea, porém o volume ganho se manteve estável nos grupos HA/TCP e Bio-Oss, mas não no grupo AUT, onde esse volume reduziu drasticamente devido aceleração na remodelação óssea, com predomínio da reabsorção osteoclástica aliada à pressão sinusal. Conclui-se que o ganho ósseo no levantamento de seio maxilar com o HA/TCPp ou Bio-Oss mantémse estável porque oferece melhor resistência contra a pressão sinusal e a repneumatização em relação ao obtido com enxerto autógeno. A associação do PRP ao enxerto autógeno acelera o processo de formação/remodelação óssea, porém a sua associação ao HA/TCPp ou Bio-Oss não influencia no ganho final de volume ósseo, mas aumenta a velocidade de sua maturação. / This study investigated the bone gain and quality achieved by utilization of biphasic porous ceramic HA/TCPp compared to autogenous bone graft and Bio-Oss® associated or not with platelet-rich plasma (PRP), in maxillary sinus lift surgeries in rabbits. Bilateral sinus lift was performed in 54 rabbits, being one side filled with graft/biomaterial and blood (SG) and the contralateral side was filled with graft/biomaterial and PRP, and the treatment groups were designed as HA/TCPp/SG, HA/TCPp/PRP, AUT/SG, AUT/PRP, Bio-Oss/SG and Bio-Oss/PRP. After periods of 30, 60 and 180 days (n=18/period), the histological specimens were collected and fixed in buffered 10% formalin. Following, microtomographic images were obtained and the specimens were histologically processed. The volume and height of the lifted maxillary sinus were determined on the microtomographic images, and the percentage and volume of graft/biomaterial and bone tissue were morphometrically evaluated on the histological sections by point counting volumetry. Data were compared by threeway ANOVA and the means were compared by the Tukey test, at significance level of 5%. The volume and height of the lifted maxillary sinus were stable in the groups Bio- Oss and HA/TCP, with mean values of 154.9mm3 and 5.6mm between 30 and 180 days respectively, while in the group AUT the same dimensions were reduced in 33.3% and 21.7%, respectively. The autogenous graft exhibited fast resorption with concomitant intense new bone formation and remodeling up to 60 days. Between 60 and 180 days, the increase in bone volume was not maintained, reducing in 52.5%. The association of AUT graft with PRP accelerated the new bone formation/remodeling process and the osteoclastic resorption of grafted particles. Conversely, the volume of Bio-Oss® and HA/TCP was nearly unchanged throughout the period and bone formation occurred in the spaces between particles, filling a mean volume of 42.85mm3 at 60 days, which was maintained up to 180 days. The addition of PRP to the biomaterials Bio-Oss® and HA/TCPp did not promote changes in the quantity of newly formed bone, yet accelerated its maturation in relation to groups associated with SG. The three materials presently used for maxillary sinus lift allowed significant bone formation, yet the volume gain was stable in the groups HA/TCP and Bio-Oss but not in the group AUT, in which this volume was dramatically reduced due to the accelerated bone remodeling, with predominance of osteoclastic resorption associated with sinus pressure. It was concluded that, the bone gain in maxillary sinus lift with HA/TCPp or Bio-Oss remains stable because it offers better strength against the sinus pressure and pneumatization compared to that obtained with autograft. The association of PRP with the autogenous graft accelerates the process of bone formation/remodeling, yet its association with HA/TCPp or Bio-Oss does not influence the final bone volume gain, but increases the rate of bone maturation.
|
208 |
Avaliação microtomográfica e histomorfométrica comparativa de levantamento de seio maxilar em coelhos utilizando diferentes cerâmicas a base de fosfato de cálcio / Comparative microtomographic and histomorphometric evaluation of maxillary sinus augmentation using different calcium phosphate-based ceramicsPaula Sanches dos Santos 25 May 2016 (has links)
A técnica de levantamento de seio maxilar (LSM) visa aumentar a altura óssea junto à superfície sinusal de maxila posterior atrófica utilizando diferentes materiais de preenchimento, para possibilitar a instalação de implantes dentários. Esses materiais de preenchimento podem variar quanto à origem e às propriedades físicoquímicas, resultando em diferentes respostas biológicas. O objetivo do atual trabalho foi avaliar a eficiência do Gen-Ox®inorg e GenPhos XP® na técnica de elevação do seio maxilar em comparação ao Bio-Oss®. Em 24 coelhos foi realizado o levantamento bilateral dos seios maxilares (SMs) utilizando 200 mm3 de material de preenchimento por seio, conforme os grupos experimentais Bio-Oss (6SMs/período), Gen-Ox (5SMs/período) e GenPhos (5SMs/período), e a janela óssea de acesso foi recoberta com uma membrana reabsorvível. Os animais de cada grupo foram eutanasiados aos 15, 30 e 60 dias e a região dos SMs foi coletada e fixada em formalina a 10% tamponada. As peças foram submetidas à análise microtomográfica para determinação do volume total do SM elevado e em seguida ao processamento histológico, sendo cortes coronais dos SMs obtidos e avaliados morfometricamente pelo método de volumetria de pontos. Todos os três materiais apresentaram excelente biocompatibilidade e promoveram a manutenção do volume do seio preenchido ao longo do tempo, sendo em média de 214,1 mm3. Em todos os grupos a formação óssea ocorreu em íntimo contato com as partículas de material. Ao término de 60 dias, o tecido ósseo formado mostrava-se maduro e preenchia parcialmente os espaços entre as partículas. A forma e tamanho das partículas de Gen-Ox gerou maior espaço entre as partículas que pode ter levado a formação de maior volume de tecido ósseo e de tecido conjuntivo (53,0 ± 10,1 mm3 e 74,1 ± 21,5 mm3) comparado ao Bio-Oss (43,7 ± 11,6 mm3 e 61,2 ± 23,3 mm3) e GenPhos (47,5 ± 10,4 mm3 e 58,5 ± 25,7 mm3). Baseado na estabilidade do volume sinusal elevado, na capacidade osteocondutora e na formação e maturidade óssea ao longo do tempo promovidos pelo Gen-Ox®inorg e GenPhos®, comparável ao do Bio-Oss®, conclui-se que esses dois biomateriais significam uma alternativa segura na técnica de LSM. / Maxillary sinus augmentation (MSA) for implant placement using bone graft or bone substitutes is a common procedure to increase the bone volume in the atrophic posterior part of the maxilla. Various bone substitutes have been used in sinus floor elevation procedures. Nonetheless, the biological performance of bone substitutes may vary according to origin, physical and chemical properties. The goal of this study was to evaluate the efficiency of both Gen-Ox®inorg and GenPhos XP® in maxillary sinus augmentation technique compared to Bio-Oss®. In 24 rabbits, it was conducted a bilateral lifting of the maxillary sinuses (MSs) using 200 mm3 of filling material for sinus in accordance with the experimental groups Bio-Oss (6SMs/period), Gen-Ox (5MSs/period) and GenPhos (5MSs/period). The sinus access window was covered with a resorbable membrane. The animals of each group were euthanized at 15, 30 and 60 days and the MSs were collected and fixed in 10% buffered formalin. The samples were submitted to microtomographic analysis to calculate the MS augmentation volume. Histological coronal sections of MS augmentation were used for morphological analysis and determination of volume density of each structure by point counting volumetry method. All three materials had excellent biocompatibility and promoted maintenance of the MS augmentation volume over time, averaging 214.1 mm3. In all groups the bone formation occurred in close contact with the material particles. At the end of 60 days, the bone tissue formed was mature and it partially filled the spaces between the particles. The shape and size of Gen-Ox particles generated greater space between the particles that may have led to a higher formation of bone volume and connective tissue (53.0 ± 10.1 mm3 and 74.1 ± 21.5 mm3) than Bio-Oss (43.7 ± 11.6 mm3 and 61.2 ± 23.3 mm3) and GenPhos (47.5 ± 10.4 mm3 and 58.5 ± 25.7 mm3). Based on the stability of the MS volume, the osteoconductive capacity and the bone formation and maturation over time promoted by Gen-Ox®inorg and GenPhos®, and comparable to Bio-Oss®, it is concluded that these two biomaterials may be a safe alternative in MSA technique.
|
209 |
Esponja do biopolímero de cana-de-açúcar no tratamento de trauma renal extenso induzido em coelhosTAVARES, Leandro Henrique de Mesquita 22 August 2012 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2017-02-06T17:32:01Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
05 LEANDRO.pdf: 1567255 bytes, checksum: 524598baa8a0da3ae61f6dd0f193fb70 (MD5) / Made available in DSpace on 2017-02-06T17:32:01Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
05 LEANDRO.pdf: 1567255 bytes, checksum: 524598baa8a0da3ae61f6dd0f193fb70 (MD5)
Previous issue date: 2012-08-22 / Introdução: A reconstrução do parênquima renal requer, em algumas situações, uma
técnica cirúrgica mais complexa e delicada. O trauma renal de alto grau e as nefrectomias
parciais para remoção de tumores malignos induzem a uma reconstrução renal de difícil
execução e possuem um potencial elevado para causar perda completa do órgão. A
utilização de substâncias auxiliares na reconstrução renal, tais como: selantes biológicos e
hemostáticos têm fundamental importância para a sua preservação. OBJETIVO: Avaliar o
efeito hemostático e selante da esponja do biopolímero da cana-de-açúcar em trauma renal
de alto grau induzido em coelhos. MÉTODOS: Foi realizado um estudo experimental,
prospectivo e pareado, com vinte e quatro unidades renais de doze coelhos da linhagem
California. Após indução de trauma renal bilateral e de alto grau (lesão da via coletora),
utilizamos, para a reconstrução e hemostasia do parênquima renal direito, a esponja do
biopolímero da cana-de-açúcar, e à esquerda, foi utilizada a esponja de Surgifoam®. Nos
dois lados, foi realizada uma sutura com fio de poliglactina 4/0 sobre as esponjas. Desta
forma, cada coelho se tornou controle de si mesmo. Durante o procedimento cirúrgico, foram
avaliados: o tempo cirúrgico total, o tempo para hemostasia e o grau de perda sanguínea.
Os animais foram sacrificados após quatro semanas, sendo os rins retirados e
encaminhados para a análise histológica. Foi avaliada a presença de fístulas, urinoma,
hematomas e aderências aos órgãos adjacentes no momento da nefrectomia. A análise
histológica observou o grau de inflamação e fibrose, assim como presença de necrose.
RESULTADOS: Em relação ao tamanho dos rins, não houve diferença estatística entre os
grupos (p=0,058), o que configura uma homogeneidade entre eles. Da mesma forma, o
tempo para hemostasia foi similar (p=0,195) e a perda sanguínea (p=0,480). Por outro lado,
foi notada uma maior incidência de aderências aos órgãos adjacentes no grupo do BCPA,
assim como, uma maior intensidade da resposta inflamatória a corpo estranho (p=0,004).
Todavia, sem influência nos resultados finais. Não foi evidenciada a ocorrência de
hemorragia maciça, formação de hematomas, abscessos, fístulas ou cálculos em nenhuma
das unidades renais. A presença de fibrose e necrose foi semelhante nos dois grupos do
ponto de vista estatístico (p=0,500 e 0,414, respectivamente). CONCLUSÃO: A esponja do
biopolímero da cana-de-açúcar demonstrou eficácia em relação ao controle hemostático e
selante sobre o parênquima renal de coelhos, sem causar complicações importantes.
Futuros estudos podem direcionar seu uso rotineiro na prática urológica. / Introduction: The reconstruction of the renal parenchyma requires, in some situations, a
surgical technique more complex and delicate. The high grade renal trauma and partial
nephrectomy for removal of malignant tumors induce a kidney reconstruction difficult to
implement and have a high potential to cause complete loss of the organ. The use of
auxiliary substances in renal reconstruction, such as biological sealants and hemostatic are
of enormous value to their preservation. Objective: To evaluate the effect of sealant and
hemostatic sponge biopolymer of sugarcane in high grade renal trauma induced in rabbits.
Methods: We conducted an experimental study, prospective, matched, with twenty-four
renal units of twelve rabbits from California lineage. After induction of bilateral renal trauma
and high-grade lesions, it was used for the reconstruction of right renal parenchymal, the
biopolymer sponge of cane sugar, and in left kidney, we used the sponge Surgifoam®. On
both sides, we performed a suture with polyglactin 4/0 on the sponges. Thus, each rabbit has
control of himself. During surgery, we evaluated the total surgical time, time to hemostasis
and the degree of blood loss. The animals were sacrificed after four weeks, and the kidneys
removed and sent for histological analysis. We evaluated the presence of fistula, urinoma,
hematoma, and adhesions to adjacent organs at the time of nephrectomy. Histological
analysis showed the degree of inflammation and fibrosis, as well as necrosis. Results: In
relation to the size of the kidneys, there was no statistical difference between groups (p =
0.058), which is one commonality between them. Similarly, time to hemostasis was similar (p
= 0.195) and blood loss (p = 0.480). Moreover, it was noted an increased incidence of
adhesions to adjacent organs in BCPA group, as well as a greater inflammatory response to
foreign bodies (p = 0.004). However, no influence on final results. There was no evidence the
occurrence of massive bleeding, hematomas, abscesses, fistulas, or in any calculations of
renal units. The presence of fibrosis and necrosis was similar in both groups a statistically (p
= 0.500 and 0.414, respectively). Conclusion: The biopolymer sponge of sugarcane has
shown efficacy in the hemostatic control and sealant on the renal cortex of rabbits, without
causing major complications. Future studies may direct its routine use in urologic practice.
|
210 |
Avaliação da radiopacidade, do pH e da atividade antimicrobiana do MTA, do cimento Portland puro e do cimento Portland adicionado de agentes radiopacificadoresLima, Marta Judite Nunes 26 February 2016 (has links)
Introduction: The radiopacity is a required property in all dental materials. This characteristic allows this materials be able to be distinguished from the tooth surfaces through the radiography. Portland cement (PC) presents physico-chemical and biological properties similar to mineral trioxide aggregate (MTA), except for radiopacifier. Objective: To evaluate the radiopacity, antimicrobial activity and pH of the MTA, pure PC and PC added different radiopacifiers. Materials and Methods: The radiopacity of MTA, pure PC and PC added the radiopacifying: iodoform, lead oxide, zirconium oxide, bismuth subnitrate, barium sulfate and bismuth oxide in the proportions 15%, 20% and 30% were analyzed. The radiopacity was carried out using a semi-direct digital radiography system (Instrumentarium Kavo EXPRESS®). The PC and cements selected with adequate radiopacity (ANSI/ADA No. 57) were evaluated for their antimicrobial activity and pH. Antimicrobial activity was analyzed by microdilution tests and agar diffusion. The microorganism tested were Enterococcus faecalis, as a standard strain (ATCC 29212) and six clinical strains (LMA 26, LMA 27, LMA 28, LMA 29, LMA 31 and LMA 34). The pH was measured using a digital pH meter (pH Meter Pocket-sized). Statistical analyzes were performed using the Shapiro-Wilk normality test, ANOVA and Tukey with significance level of 5%. Results: Pure PC had the lowest radiopacity. The MTA, PC + iodoform 20% (3.59 mmEq.Al), PC + bismuth oxide 20% (4.79 mmEq.Al), PC + bismuth subnitrate 20% (3.12 mmEq.Al), PC + 20% lead oxide (3.18 mmEq.Al) and PC + 30% zirconium oxide (4.28 mmEq.Al). Regarding the agar diffusion test, the LMA 26 strain was inhibited by PC, PC + Iodoform 20%, PC + 30% Zirconium Oxide, PC + Bismuth subnitrate 20%, and PC + Bismuth Oxide 20%. The LMA 31 strain was inhibited by PC + zirconium oxide 30% and PC + bismuth subnitrate 20% and LMA 27 strain was inhibited by PC + bismuth subnitrate 20%. The other strains were not inhibited. In the microdilution test, most strains was inhibited by tested materials, except the ATCC 29212 strain which was not inhibited by PC + lead oxide 20%. LMA 28 29, 31 and 34 strains were not inhibited by PC + lead oxide 20%and PC + zirconium oxide 30%, in which LMA 28 and 29 strains were not inhibited by PC + bismuth oxide20%. All cements tested showed alkalinity in all experimental periods, in which MTA had the lowest pH. Conclusions: MTA and PC added the radiopacifiers subnitrate bismuth and iodoform in concentrations of 20% by weight, provided satisfactory radiopacity, alkaline medium and promoted bactericidal and bacteriostatic activities against strains of E .faecalis tested. / Introdução: A radiopacidade é uma propriedade obrigatória em todos os materiais odontológicos. Esta característica permite este material seja distinguido das superfícies dentárias através da radiografia. O cimento Portland (CP) apresenta propriedades físicoquímicas e biológicas semelhantes ao Agregado Trióxido Mineral (MTA), exceto pela partícula radiopacificadora. Objetivo: Avaliar a radiopacidade, atividade antimicrobiana e pH do MTA, CP puro e CP adicionado de diferentes radiopacificadores. Materiais e Métodos: Foi analisada a radiopacidade do MTA, CP e CP adicionado dos radiopacificadores: iodofórmio, óxido de chumbo, óxido de zircônio, subnitrato de bismuto, sulfato de bário e óxido de bismuto nas proporções 15%, 20% e 30%. A radiopacidade foi avaliada por meio do sistema de radiografia digital semi-direto (Instrumentarium Kavo EXPRESS®). O CP e os cimentos selecionados com radiopacidade adequada (ANSI/ADA nº 57) foram submetidos à avaliação da atividade antimicrobiana e do pH. A atividade antimicrobiana foi analisada pelos testes de microdiluição e difusão em ágar. O micro-organismo testado foi o Enterococcus faecalis, sendo uma cepa padrão (ATCC 29212) e seis cepas clínicas (LMA 26, LMA 27, LMA 28, LMA 29, LMA 31 e LMA 34). O pH foi aferido com pHmetro digital (pH Meter Pocket-sized). Os testes estatísticos utilizados foram os testes Shapiro-Wilk de normalidade, análise de variância ANOVA e Tukey a nível de significância de 5%. Resultados: O CP puro apresentou o menor valor de radiopacidade, O MTA, CP + iodofórmio 20% (3,59 mmEq.Al), CP + óxido de bismuto 20% (4,79 mmEq.Al), CP + subnitrato de bismuto 20% (3,12 mmEq.Al), CP + óxido de chumbo 20% (3,18 mmEq.Al) e CP + óxido de zircônio 30% (4,28 mmEq.Al). No teste de difusão em ágar, a cepa LMA 26 foi inibida pelo CP, CP + Iodofórmio 20%, CP + Óxido de Zircônio 30%, CP + Subnitrato de Bismuto 20% e CP + Óxido de Bismuto 20%. A cepa LMA 31 foi inibida pelas associações CP + óxido de zircônio 30% e CP + subnitrato de bismuto 20% e a cepa LMA 27 foi inibida pelo CP + subnitrato de bismuto 20%. As demais cepas não foram inibidas. No teste de microdiluição, a maioria das cepas foi inibida pelos materiais-testes, exceto a cepa ATCC 29212 que não foi inibida pelo CP + óxido de chumbo 20%, as cepas LMA 28, 29, 31 e 34 não foram inibidas pelas associações CP + óxido de chumbo 20% e CP + óxido de zircônio 30%, sendo que as cepas LMA 28 e 29 também não foram inibidas pelo CP + óxido de bismuto 20%. Todos os cimentos testados apresentaram alcalinidade em todos os períodos experimentais, sendo que o MTA apresentou os menores valores de pH. Conclusões: O MTA e as concentrações de CP adicionado de 20% do agente radiopacificador subnitrato de
bismuto e CP adicionado do agente radiopacificador iodofórmio, 20% em peso, proporcionaram radiopacidade satisfatória, alcalinizaram o meio e promoveram atividades bactericida e bacteriostática contra as cepas de E. faecalis testadas.
|
Page generated in 0.0568 seconds