• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 67
  • 67
  • 67
  • 32
  • 16
  • 16
  • 15
  • 15
  • 15
  • 13
  • 12
  • 11
  • 10
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Biological Effective Dose (BED) Distribution Matching for Obtaining Brachytherapy Prescription Doses & Dosimetric Optimization for Hybrid Seed Brachytherapy

Pritz, Jakub 01 January 2011 (has links)
Radioactive seed implant brachytherapy is a common radiotherapy treatment method for prostate cancer. In current clinical practice, a seed consists of a single isotope, such as 125I or 103Pd. A seed containing a mixture of two isotopes has been proposed for prostate cancer treatment. This study investigates a method for defining a prescription dose for new seed compositions based on matching the biological equivalent dose (BED) of a reference plan. Ten prostate cancer cases previously treated using single isotope seeds (5 using 125I seeds and 5 using 103Pd seeds) were selected for this study. Verification of the method was done by calculating prescription doses for 103Pd and 125I seeds. A prescription dose for a 50/50 hybrid seed was calculated. Number and location of seeds remained invariant within each case. The BED distributions for hybrid and single isotope seed plans were generated and matched to the BED distribution generated off of the optimized plans. For the 125I isotopes, the dose necessary to cover 90% of the prostate with a BED of 110 Gy is 145 Gy. For the same BED coverage, the dose for 103Pd and 50/50 hybrid seed is 120 Gy and 137 Gy respectively. A method is introduced for obtaining prescription doses for new brachytherapy sources. The method was verified by obtaining doses for 125I and 103Pd isotopes which match clinical prescription doses. The method developed is robust enough to calculate prescription doses in any region of interest, for any seed type, and for any isotope as long as the BED coverage remains invariant with respect to the treatment plan. Numerical calculations were performed to derive analytical conversions of total dose to BED for 50/50, 75/25 and 25/75 hybrid seeds. These analytical conversions are faster than the original numerical methods employed allowing for real-time BED optimization for hybrid seeds. Varying seed distribution was seen not to influence the analytical conversions. It was observed that when total dose remained invariant while individual isotope contributions varied, the value of BED varied. The BED variance was seen to be the smaller at larger BED values (~2% at 100 Gy). Using the conversions derived in this paper, BED based optimization for hybrid seeds are now performable. However, these conversions should only be used in high dose regions due to high uncertainty in the low regime.
52

NONCONTACT DIFFUSE CORRELATION TOMOGRAPHY OF BREAST TUMOR

He, Lian 01 January 2015 (has links)
Since aggressive cancers are frequently hypermetabolic with angiogenic vessels, quantification of blood flow (BF) can be vital for cancer diagnosis. Our laboratory has developed a noncontact diffuse correlation tomography (ncDCT) system for 3-D imaging of BF distribution in deep tissues (up to centimeters). The ncDCT system employs two sets of optical lenses to project source and detector fibers respectively onto the tissue surface, and applies finite element framework to model light transportation in complex tissue geometries. This thesis reports our first step to adapt the ncDCT system for 3-D imaging of BF contrasts in human breast tumors. A commercial 3-D camera was used to obtain breast surface geometry which was then converted to a solid volume mesh. An ncDCT probe scanned over a region of interest on the breast mesh surface and the measured boundary data were used for 3-D image reconstruction of BF distribution. This technique was tested with computer simulations and in 28 patients with breast tumors. Results from computer simulations suggest that relatively high accuracy can be achieved when the entire tumor was within the sensitive region of diffuse light. Image reconstruction with a priori knowledge of the tumor volume and location can significantly improve the accuracy in recovery of tumor BF contrasts. In vivo ncDCT imaging results from the majority of breast tumors showed higher BF contrasts in the tumor regions compared to the surrounding tissues. Reconstructed tumor depths and dimensions matched ultrasound imaging results when the tumors were within the sensitive region of light propagation. The results demonstrate that ncDCT system has the potential to image BF distributions in soft and vulnerable tissues without distorting tissue hemodynamics. In addition to this primary study, detector fibers with different modes (i.e., single-mode, few-mode, multimode) for photon collection were experimentally explored to improve the signal-to-noise ratio of diffuse correlation spectroscopy flow-oximeter measurements.
53

The Effect of Hyperthermia on Doxorubicin Therapy and Nanoparticle Penetration in Multicellular Ovarian Cancer Spheroids

Nagesetti, Abhignyan 12 February 2017 (has links)
The efficient treatment of cancer with chemotherapy is challenged by the limited penetration of drugs into the tumor. Nanoparticles (10 – 100 nanometers) have emerged as a logical choice to specifically deliver chemotherapeutics to tumors, however, their transport into the tumor is also impeded owing to their bigger size compared to free drug moieties. Currently, monolayer cell cultures, as models for drug testing, cannot recapitulate the structural and functional complexity of in-vivo tumors. Furthermore, strategies to improve drug distribution in tumor tissues are also required. In this study, we hypothesized that hyperthermia (43°C) will improve the distribution of silica nanoparticles in three-dimensional multicellular tumor spheroids. Tumor spheroids mimic the functional and histomorphological complexity of in-vivo avascular tumors and are therefore valuable tools to study drug distribution. Ovarian cancer (Skov3) and uterine sarcoma (MES-SA/Dx5) spheroids were generated using the liquid overlay method. The growth ratio and cytotoxicity assays showed that the application of adjuvant hyperthermia with Doxorubicin (DOX) did not yield higher cell killing compared to DOX therapy alone. These results illustrated the role of spheroids in resistance to heat and DOX. In order to study the cellular uptake kinetics of nanoparticles under hyperthermia conditions, the experimental measurements of silica nanoparticle uptake by cells were fitted using a novel inverse estimation method based on Bayesian estimation. This was coupled with advection reaction transport to model nanoparticle transport in spheroids. The model predicted an increase in Area Under the Curve (AUC) and penetration distance (W1/2) that were validated with in-vitro experiments in spheroids. Based on these observations, a novel multifunctional theranostic nanoparticle probe was created for generating highly localized hyperthermia by encapsulating a Near Infrared (NIR) dye, IR820 (for imaging and hyperthermia) and DOX in Organically modified silica nanoparticles (Ormosil). Pegylated Ormosil nanoparticles had an average diameter of 58.2±3.1 nm, zeta potential of -6.9 ± 0.1 mV and high colloidal stability in physiological buffers. Exposure of the IR820 within the nanoparticles to NIR laser led to the generation of hyperthermia as well as release of DOX which translated to higher cell killing in Skov3 cells, deeper penetration of DOX into spheroids and complete destruction of the spheroids. In-vivo bio-distribution studies showed higher fluorescence from organs and increased plasma elimination life of IR820 compared to free IR820. However, possible aggregation of particles on laser exposure and accumulation in lungs still remain a concern.
54

Cobalt Ferrite Nanoparticles Fabricated via Co-precipitation in Air: Overview of Size Control and Magnetic Properties

Toledo, Dennis 13 November 2015 (has links)
Cobalt Ferrite has important, size-dependent magnetic properties. Consequently, an overview of particle size is important. Co-precipitation in air was the fabrication method used because it is comparatively simple and safe. The effects of three different reaction times including 1, 2, 3 hour(s) on particle size were compared. Also, the effectiveness of three different capping agents (Oleic Acid, Polyvinylpyrollidone (PVP), and Trisodium Citrate) in reducing aggregation and correspondingly particle size were examined. Using Welch’s analysis of variance (ANOVA) and the relevant post hoc tests, there was no significant difference (p=0.05) between reaction times of 1 hour and 2 hours, but there was a significant difference between reaction times of 2 hours and 3 hours. Potentially, because of increased coarsening for the 3 hour reaction time. PVP and Oleic Acid were shown to be effective in reducing aggregation; however, Citrate was not effective. Possibly, the synthesis procedure was inadequate.
55

Funtional Near Infrared Spectroscopy Study of Language, Joint Attention and Motor Skills

Chaudhary, Ujwal 27 June 2013 (has links)
Near infrared spectroscopy (NIRS) is an emerging non-invasive optical neuro imaging technique that monitors the hemodynamic response to brain activation with ms-scale temporal resolution and sub-cm spatial resolution. The overall goal of my dissertation was to develop and apply NIRS towards investigation of neurological response to language, joint attention and planning and execution of motor skills in healthy adults. Language studies were performed to investigate the hemodynamic response, synchrony and dominance feature of the frontal and fronto-temporal cortex of healthy adults in response to language reception and expression. The mathematical model developed based on granger causality explicated the directional flow of information during the processing of language stimuli by the fronto-temporal cortex. Joint attention and planning/ execution of motor skill studies were performed to investigate the hemodynamic response, synchrony and dominance feature of the frontal cortex of healthy adults and in children (5-8 years old) with autism (for joint attention studies) and individuals with cerebral palsy (for planning/execution of motor skills studies). The joint attention studies on healthy adults showed differences in activation as well as intensity and phase dependent connectivity in the frontal cortex during joint attention in comparison to rest. The joint attention studies on typically developing children showed differences in frontal cortical activation in comparison to that in children with autism. The planning and execution of motor skills studies on healthy adults and individuals with cerebral palsy (CP) showed difference in the frontal cortical dominance, that is, bilateral and ipsilateral dominance, respectively. The planning and execution of motor skills studies also demonstrated the plastic and learning behavior of brain wherein correlation was found between the relative change in total hemoglobin in the frontal cortex and the kinematics of the activity performed by the participants. Thus, during my dissertation the NIRS neuroimaging technique was successfully implemented to investigate the neurological response of language, joint attention and planning and execution of motor skills in healthy adults as well as preliminarily on children with autism and individuals with cerebral palsy. These NIRS studies have long-term potential for the design of early stage interventions in children with autism and customized rehabilitation in individuals with cerebral palsy.
56

Effects of Malformed or Absent Valves to Lymphatic Fluid Transport and Lymphedema in Vivo in Mice

Pujari, Akshay S. 27 October 2017 (has links)
Lymph is primarily composed of fluid and proteins from the blood circulatory system that drain into the space surrounding cells, interstitial space. From the interstitial space, the fluid enters and circulates in the lymphatic system until it is delivered into the venous system. In contrast to the blood circulatory system, the lymphatic system lacks a central pumping organ dictating the predominant driving pressure and velocity of lymph. Transport of lymph via capillaries, pre-collecting and collecting lymphatic vessels relies on the synergy between pressure gradients, local tissue motion, valves and lymphatic vessel contractility. The direction of lymph transport is regulated by bicuspid valves distributed throughout pre-collecting and collecting lymphatic vessels. Effective transport of lymph into the venous system is of prime importance. Disruption of lymph transport, because of impaired lymphatic function, reduced numbers of vessels or valvular insufficiencies can have severe health consequences, including lymphedema for which current clinical therapies are not curative. The lymphatic valves are usually bicuspid, however, congenital malformations in the valve such as single leaflet valve formation and arrested lymphatic valve development are observed and can cause lymphedema. Here we employ 4-week-old mice to study the effects of valves and malformed valves on lymph transport shedding light into some of the potentially underlying consequences of lymphedema. Polyethylene glycol (PEG) coated latex particles were injected into the inguinal lymph node of anesthetized mice. Particle displacement measurements through efferent lymphatic vessels yielded velocity, wall shear stress, vorticity and strain of the efferent lymph flow field carrying lymph from subdermal inguinal lymph nodes. Lymphatic vessel endothelial Prox1 green fluorescent protein (GFP) marker enabled the detection of lymphatic vessel walls and valves. Flow field, flow velocity, flow rate, velocity profiles, wall shear stress, vorticity and strain values were compared in regions downstream of normal and malformed valves in two wild type mice. A Clec2-deficient mouse, which experiences lymphatic development defects and is used as a lymphedema model, was employed to further elucidate the lymphatic valves on transport. The absence of centralized pumping yields highly variable lymphatic flow cycles varying from one to fifteen seconds. The presence of lymphatic valves introduces boundary conditions that yield spatial and temporal flow gradients increasing the degree of complexity of lymph transport. The valves dictate the trajectory of the particles and promote the formation of recirculation zones. Even in the presence of valves, lymph flow commonly reverses. Congenital defects like a single leaflet valve lowers the lymph flow efficiency and promotes higher wall shear stress regions. Furthermore, the absence of functional valves in the Clec2-deficient mouse not displaying lymphedema yielded lymph flow lacking the pulsatility that characterizes normal lymphatic flow.
57

Terahertz Imaging for Cancer Detection

St. Peter, Benjamin A 01 January 2012 (has links) (PDF)
This project evaluates the ability of terahertz (THz) radiation to differentiate cancerous from non-cancerous human breast lumpectomy and mastectomy tissue. This is done by aiming a narrow-band THz beam at medical samples and measuring reflected power. THz images of specimens from Breast Conservation Surgery (BCS) were created using a gas laser source and mechanical scanning. The design and characterization of this system is discussed in detail. The images were correlated with optical histological micrographs of the same specimens and discrimination values of more than 70% were found for five of the six samples using Receiver Operating Characteristic (ROC) analysis.
58

The Electrical Properties of Human Tissue for the Diagnosis and Treatment of Melanoma Skin Cancer

Stante, Glenn Cameron 01 December 2009 (has links) (PDF)
This thesis discusses the research, experimental methods, and data gathered for the investigation of a novel method for the diagnosis of melanoma skin cancer. First, a background about human skin tissue is presented. Then, a detailed description of melanoma along with current diagnosis techniques and treatment options are presented. In the experimental methods, the electrical properties of several types of tissue were analyzed, the purpose of which was to discover if a tissue type can be distinguished by its electrical properties alone. This would allow for the diagnosis of melanoma to be done by examining the electrical properties of the suspected tumor and comparing the results to known values of healthy and cancerous skin. After analyzing the data, it was concluded that tissue types can be identified by their electrical properties and it may be possible to diagnose melanoma through this method. Finally, the possibility of using a similar technology and radiofrequency tissue ablation to treat melanoma is presented.
59

Characterization of Two Vernier-Tuned Distributed Bragg Reflector (VT-DBR) Lasers Used in Swept Source Optical Coherence Tomography (SS-OCT)

Bergdoll, Greg M 01 June 2015 (has links) (PDF)
Insight Photonic Solutions Inc. has continued to develop their patented VT-DBR laser design; these wavelength tunable lasers promise marked image-quality and acquisition time improvements in SS-OCT applications. To be well suited for SS-OCT, tunable lasers must be capable of producing a highly linear wavelength sweep across a tuning range well-matched to the medium being imaged; many different tunable lasers used in SS-OCT are compared to identify the optimal solution. This work electrically and spectrally characterizes two completely new all-semiconductor VT-DBR designs to compare, as well. The Neptune VT-DBR, an O-band laser, operates around the 1310 nm range and is a robust solution for many OCT applications. The VTL-2 is the first 1060 nm VT-DBR laser to be demonstrated. It offers improved penetration through water over earlier designs which operate at longer wavelengths (e.g. - 1550 nm and 1310 nm), making it an optimal solution for the relatively deep imaging requirements of the human eye; the non-invasive nature of OCT makes it the ideal imaging technology for ophthalmology. Each laser has five semiconductor P-N junction segments that collectively enable precise akinetic wavelength-tuning (i.e. - the tuning mechanism has no moving parts). In an SS-OCT system utilizing one of these laser packages, the segments are synchronously driven with high speed current signals that achieve the desired wavelength, power, and sweep pattern of the optical output. To validate the laser’s fast tuning response time necessary for its use in SS-OCT, a circuit model of each tuning section is created; each laser section is modeled as a diode with a significant lead inductance. The dynamic resistance, effective capacitance, and lead inductance of this model are measured as a function of bias current and the response time corresponding to each bias condition is determined. Tuning maps, spectral linewidths, and side-mode suppression ratio (SMSR) measurements important to SS-OCT performance are also collected. Measured response times vary from 700 ps to 2 ns for the Neptune and 1.2 to 2.3 ns for the VTL-2. Linewidth measurements range from 9 MHz to 124 MHz for the Neptune and 300 kHz to 2 MHz for the VTL-2. SMSR measurements greater than 38 dB and 40 dB were observed for the Neptune and VTL-2, respectively. Collectively, these results implicate the VT-DBR lasers as ideal tunable sources for use in SS-OCT applications.
60

DIFFUSE OPTICAL MEASUREMENTS OF HEAD AND NECK TUMOR HEMODYNAMICS FOR EARLY PREDICTION OF CHEMO-RADIATION THERAPY OUTCOMES

Dong, Lixin 01 January 2015 (has links)
Chemo-radiation therapy is a principal modality for the treatment of head and neck cancers, and its efficacy depends on the interaction of tumor oxygen with free radicals. In this study, we adopted a novel hybrid diffuse optical instrument combining a commercial frequency-domain tissue oximeter (Imagent) and a custom-made diffuse correlation spectroscopy (DCS) flowmeter, which allowed for simultaneous measurements of tumor blood flow and blood oxygenation. Using this hybrid instrument we continually measured tumor hemodynamic responses to chemo-radiation therapy over the treatment period of 7 weeks. We also explored monitoring dynamic tumor hemodynamic changes during radiation delivery. Blood flow data analysis was improved by simultaneously extracting multiple parameters from one single autocorrelation function curve measured by DCS. Patients were classified into two groups based on clinical outcomes: a complete response (CR) group and an incomplete response (IR) group with remote metastasis and/or local recurrence within one year. Interestingly, we found human papilloma virus (HPV-16) status largely affected tumor homodynamic responses to therapy. Significant differences in tumor blood flow index (BFI) and reduced scattering coefficient (μs’) between the IR and CR groups were observed in HPV-16 negative patients at Week 3. Significant differences in oxygenated hemoglobin concentration ([HbO2]) and blood oxygen saturation (StO2) between the two groups were found in HPV-16 positive patients at Week 1 and Week 3, respectively. Receiver operating characteristic curves were constructed and results indicated high sensitivities and specificities of these hemodynamic parameters for early (within the first three weeks of the treatment) prediction of one-year treatment outcomes. Measurement of tumor hemodynamics may serve as a predictive tool allowing treatment selection based on biologic tumor characteristics. Ultimately, reduction of side effects in patients not benefiting from radiation treatment may be feasible.

Page generated in 1.4305 seconds