• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 2
  • 1
  • Tagged with
  • 9
  • 9
  • 8
  • 7
  • 6
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Limitation du colmatage dans les bioréacteurs à membranes à l'échelle industrielle : modélisation et caractérisation de l'hydrodynamique

Suard, Elodie 13 November 2018 (has links) (PDF)
Malgré leur fort développement en assainissement domestique urbain, les bioréacteurs à membranes (BaM) pâtissent de phénomènes de colmatage, induisant des coûts énergétiques et de maintenance importants. L’aération séquencée des membranes par des grosses bulles est l’une des stratégies pour limiter le colmatage ; son impact a fait l’objet de plusieurs études mais reste globalement mal compris, notamment du fait de la complexité de ces systèmes, multiphasiques et opaques. L’hydrodynamique des réacteurs reste mal caractérisée en présence de boues. Pour apporter des éléments de compréhension aux mécanismes de limitation du colmatage par injection d’air, un pilote de filtration membranaire semi-industriel (2 m3, 3 sous modules fibres creuses Puron®) a été conçu, dimensionné et installé sur l’unité de traitement des jus (TDJ) de la station d’épuration Seine Aval (SIAAP), afin d’être alimenté en boues biologiques dans des conditions réelles de fonctionnement. Le suivi des paramètres opératoires du pilote et de ses performances de filtration sur une période de 5 mois avait un double objectif : (i) mieux caractériser la dispersion du gaz pour différentes conditions de fonctionnement (paramètres de l’aération, concentration en boues de l’alimentation), (ii) hiérarchiser les facteurs qui limitent le colmatage des membranes. Il s’agit in fine de proposer des stratégies d’aération adaptées et efficaces pour limiter le colmatage. Afin de caractériser la dispersion du gaz dans le réacteur, une méthodologie innovante basée sur la tomographie de résistivité électrique (ERT) a été adaptée au pilote. Les conditions d’utilisation de l’ERT (nombre d’électrodes de mesure, séquence de quadripôles) ont été sélectionnées à travers une étude numérique, de même que les paramètres d’inversion nécessaires pour reconstituer la cartographie des résistivités à partir des mesures expérimentales. Cette étude numérique poussée, réalisée sous COMSOL, a permis de conclure à l’intérêt de la méthode pour représenter la distribution des phases dans la géométrie considérée. L’ERT a donc été appliquée au pilote alimenté en boues, pour différentes conditions d’aération. Le jeu de données de filtration a par ailleurs été analysé par logique floue, à l’aide du logiciel FisPro. Les arbres de décision obtenus, en analysant les résultats de manière globale et en les regroupant par conditions opératoires similaires, ont mis en évidence l’impact prépondérant des variables suivantes sur la dérive de perméabilité observée (comprise entre - 9 et 2 LMH/bar) : la différence de DCO entre le surnageant des boues et le perméat (DDCO) traduisant une phase colloïdale complexe, et la concentration en matières en suspension (MES), ayant toutes deux un impact négatif sur les performances de filtration. Une augmentation du débit d’air conduirait à une limitation de la dérive de perméabilité, sauf lorsque la variable DCO est élevée (> à 500 mg/L), cette hypothèse restant cependant à vérifier sur une base de données plus conséquente. Le modèle ainsi obtenu par logique floue permet de mieux simuler les évolutions de perméabilité que les modèles obtenus par régression linéaire multivariée (erreurs de 0,61 et de 0,70 respectivement), et ce malgré une incertitude relative importante sur la mesure de perméabilité (jusqu’à 16 %). Ces résultats sont cohérents avec la dispersion du gaz observée par ERT : son homogénéité dépend de la concentration en MES et du débit d’air injecté. A forte concentration en MES (6 – 10 g/L), des zones préférentielles de passage des bulles ont été observées, en particulier à faible débit d’air, expliquant ainsi un colmatage plus important. L’utilisation nouvelle dans ce contexte de ces techniques, ERT et logique floue, donne des résultats qui confortent l’intérêt d’adapter l’aération (débit, séquençage) aux caractéristiques des boues notamment leurs concentrations, et qui permettent d’envisager des stratégies de contrôle de ces paramètres
2

Bioréacteur à membranes pour le traitement d'eaux usées domestiques : influence des conditions environnementales et opératoires sur l'activité des biomasses et le transfert de matière / Membrane bioreactor for urban wastewater treatment : influence of environmental and operating conditions on biological activity and mass transfer

Villain, Maud 07 December 2012 (has links)
Si le procédé de traitement des eaux usées urbaines par bioréacteur à membranes est en plein essor depuis quelques années, il ne reste pas moins plusieurs verrous technologiques qui ralentissent l'expansion de sa commercialisation. Ce travail de thèse s'attache à apporter des éléments de réponse sur quelques uns des freins à sa progression. Le premier réside dans la détermination d'un âge de boues adapté permettant une épuration maximale de l'azote et de la matière organique, par une biomasse active où le colmatage est limité et la production de boues faible. Le choix s'est porté sur 50 jours qui rempli l'ensemble de ces critères. Une autre barrière se situe dans le manque de données permettant l'extrapolation des informations obtenues en laboratoire à celles engrangées sur site. Une des étapes clés est de déterminer les conséquences du changement d'effluent (synthétique ou réel) sur les performances et le colmatage du procédé. L'utilisation d'une méthode de fluorescence récente a permis la détermination de l'implication des protéines et substances humiques-like extraits des polymères extracellulaires solubles dans le colmatage. / For several years, membrane bioreactor for urban wastewater treatment has been booming. Nevertheless some issues still slow down its expansion. This work tries to answer some of the brakes to its progression. First one concerns the choice of the suitable sludge adge which guarantee maximal removal rates of ammonium and organic matter, by an active biomasse where fouling is limited and slude production low. 50 days is fulling all the criteria. An other concern is about the lack of data allowing extrapolation from laboratory to wastewater treatment plant. One key step is to detremine the impact of influent nature (synthetic or real) on process results and fouling. Use of recent fluorescence method allows determining the implication of proteins and humic substances-like from soluble extra polymeric substances on fouling.
3

Traitement des effluents d’un service d’oncologie par bioréacteur à membranes : faisabilité d’acclimatation et gain apporté sur l’élimination de molécules médicamenteuses / Oncological ward wastewater treatment by membrane bioreactor : feasibility of biomass acclimation and improvement of pharmaceuticals removal

Hamon, Pierre 07 July 2014 (has links)
Si les risques liés à la présence de résidus médicamenteux dans l'environnement sont encore méconnus, les premiers cas avérés et l'introduction récente de trois médicaments (2013) sur une liste de surveillance de l'UE imposent d'ores et déjà le développement de procédés de traitement capables d'éliminer cette pollution spécifique. C'est dans ce contexte que le traitement des effluents d'un service d'oncologie par un bioréacteur à membranes a été évalué dans cette thèse. Les effluents collectés sont caractérisés par une importante variabilité de la charge polluante et des concentrations médicamenteuses très élevées, parfois supérieures à 1 mg.L-1. Ces conditions n'ont pas favorisé le développement continu de la biomasse épuratrice. Il a toutefois été démontré que la toxicité de ces effluents n'est pas proportionnelle à la charge appliquée puisqu'une charge massique supérieure à 0.20 kgDCO.kgMVS-1.j-1 permet la croissance de la biomasse. Le colmatage des membranes a permis une rétention significative des médicaments sélectionnés. L'élimination des médicaments sélectionnés a par ailleurs été systématiquement améliorée par les boues acclimatées avec notamment le développement de capacités de biotransformation sur des molécules parfois uniquement éliminées par sorption dans les stations d'épuration. / The risks concerning the presence of pharmaceutical residues into the environment are still unknown. However, the first confirmed cases and the recent introduction of three drugs (2013) on a surveillance list of EU already require the development of processes able to remove this specific pollution. It is against that background that oncological ward wastewater treatment by a membrane bioreactor was investigated in this thesis. These effluents are characterized by a very variable charge and high pharmaceutical concentrations, sometimes above 1 mg.L-1. These conditions did not favor the continuous development of the biomass. However, it could be demonstrated that the toxicity of these effluents is not related to the applied charge since a food to microorganisms ratio above 0.20 kgCOD.kgMLVSS-1.d-1 allows biomass growth. Membrane fouling played a major role in the significant retention of the investigated drugs. In comparison to unacclimated activated sludge from WWTP pharmaceutical removal was systematically enhanced by the acclimated biomass with the development of biotransformation possibilities.
4

Modélisation et simulation d'un bioréacteur à membranes immergées pour le traitement des eaux usées urbaines et hospitalières / Modelling and simulation of a Submerged Membrane Bioreactor for the treatment of urban and hospital wastewater.

González Hernández, Yusmel 20 December 2018 (has links)
Dans cette thèse, la modélisation d'un bioréacteur à membranes immergées (BaMI) et son évaluation avec des valeurs expérimentales de BaMI à l'échelle du banc et à l'échelle pilote pour le traitement des effluents résiduels urbains et hospitaliers, ont été étudiées respectivement. L'objectif principal de ce travail était de développer un nouveau modèle intégré plus phénoménologique pour la description du fonctionnement de ces systèmes. A cet effet, un nouveau modèle biologique a été développé en utilisant le modèle de boues activés 3 (ASM3 du l’anglais activated sludge model) et en tenant en compte la croissance et le stockage de substrat simultané, et la production de substances polymères extracellulaires solubles et liées, qui, conjointement avec des solides en suspension totales ont été les principales variables de lien avec le nouveau modèle de colmatage de la membrane, en tenant compte de l'influence de ces substances sur la porosité du gâteau. Une nouvelle procédure d'identification des paramètres pour la calibration en prenant en compte leurs influence sur le modèle et leur incertitude a été développé. Cette procédure a permis de calibrer et de valider avec succès les nouveaux modèles développés, en utilisant les données des systèmes étudiés. Parallèlement, une nouvelle méthodologie a été développée pour le fractionnement de la matière carboné selon les modèles ASM en tenant compte du phénomène de stockage du substrat. Enfin, une étude de la sensibilité paramétrique a été réalisé, où le modèle intégré a répondu de manière adéquate aux variations des principales variables qui influent sur le colmatage de la membrane, avec une élevée correspondance entre la plupart des cas et ce qui a été rapporté dans la littérature, mettant en évidence une fois de plus le caractère phénoménologique et la validité du nouveau modèle développé. / This thesis presents the modelling of a submerged membrane bioreactor (SMBR) using experimental values coming from SMBR at bench and pilot scale, for the treatment of urban and hospital wastewater respectively. The main objective of this work was to develop a global model integrating a biological model and a model for membrane fouling, with upgraded precision, consistency and calibration in the description of the functioning of these systems. For this, concerning the biological model, an evolution of the Activated Sludge Model 3 (ASM3), including the simultaneous growth and substrate storage, and the bound and soluble extracellular polymeric substances (EPS) production was proposed. The concentration of these EPS joined to those of the total suspended solids (TSS) are the variables transmitted to the new version of the membrane fouling model. This last one can take into account the influence of these substances in the cake porosity. A new procedure was developed to calibrate the parameters taking into account their influence on the model and their uncertainty. This procedure used the data obtained on experimental SMBR and respirometry. It allowed the calibration and successful validation of the developed model. At the same time, a methodology was adapted for the carbon material fractionation according to the ASM models taking into account the phenomenon of substrate storage. Finally, a parametric sensitivity study was conducted, where the global model achieved to respond adequately to the perturbations of the main variables that influence on the membrane fouling process. The high correspondence obtained between numerical and experimental results, as well as the ability of the model to explain most of the cases reported in the literature, evidence the relevance of phenomena considered in the model. Thus, the developed model is justified and the interest of the phenomenological feature of the model is highlighted.
5

Limitation du colmatage dans les bioréacteurs à membranes à l'échelle industrielle : modélisation et caractérisation de l'hydrodynamique / Fouling mitigation in industrial membrane bioreactors : modeling and hydrodynamics characterization

Suard, Elodie 13 November 2018 (has links)
Malgré leur fort développement en assainissement domestique urbain, les bioréacteurs à membranes (BaM) pâtissent de phénomènes de colmatage, induisant des coûts énergétiques et de maintenance importants. L’aération séquencée des membranes par des grosses bulles est l’une des stratégies pour limiter le colmatage ; son impact a fait l’objet de plusieurs études mais reste globalement mal compris, notamment du fait de la complexité de ces systèmes, multiphasiques et opaques. L’hydrodynamique des réacteurs reste mal caractérisée en présence de boues. Pour apporter des éléments de compréhension aux mécanismes de limitation du colmatage par injection d’air, un pilote de filtration membranaire semi-industriel (2 m3, 3 sous modules fibres creuses Puron®) a été conçu, dimensionné et installé sur l’unité de traitement des jus (TDJ) de la station d’épuration Seine Aval (SIAAP), afin d’être alimenté en boues biologiques dans des conditions réelles de fonctionnement. Le suivi des paramètres opératoires du pilote et de ses performances de filtration sur une période de 5 mois avait un double objectif : (i) mieux caractériser la dispersion du gaz pour différentes conditions de fonctionnement (paramètres de l’aération, concentration en boues de l’alimentation), (ii) hiérarchiser les facteurs qui limitent le colmatage des membranes. Il s’agit in fine de proposer des stratégies d’aération adaptées et efficaces pour limiter le colmatage. Afin de caractériser la dispersion du gaz dans le réacteur, une méthodologie innovante basée sur la tomographie de résistivité électrique (ERT) a été adaptée au pilote. Les conditions d’utilisation de l’ERT (nombre d’électrodes de mesure, séquence de quadripôles) ont été sélectionnées à travers une étude numérique, de même que les paramètres d’inversion nécessaires pour reconstituer la cartographie des résistivités à partir des mesures expérimentales. Cette étude numérique poussée, réalisée sous COMSOL, a permis de conclure à l’intérêt de la méthode pour représenter la distribution des phases dans la géométrie considérée. L’ERT a donc été appliquée au pilote alimenté en boues, pour différentes conditions d’aération. Le jeu de données de filtration a par ailleurs été analysé par logique floue, à l’aide du logiciel FisPro. Les arbres de décision obtenus, en analysant les résultats de manière globale et en les regroupant par conditions opératoires similaires, ont mis en évidence l’impact prépondérant des variables suivantes sur la dérive de perméabilité observée (comprise entre - 9 et 2 LMH/bar) : la différence de DCO entre le surnageant des boues et le perméat (DDCO) traduisant une phase colloïdale complexe, et la concentration en matières en suspension (MES), ayant toutes deux un impact négatif sur les performances de filtration. Une augmentation du débit d’air conduirait à une limitation de la dérive de perméabilité, sauf lorsque la variable DCO est élevée (> à 500 mg/L), cette hypothèse restant cependant à vérifier sur une base de données plus conséquente. Le modèle ainsi obtenu par logique floue permet de mieux simuler les évolutions de perméabilité que les modèles obtenus par régression linéaire multivariée (erreurs de 0,61 et de 0,70 respectivement), et ce malgré une incertitude relative importante sur la mesure de perméabilité (jusqu’à 16 %). Ces résultats sont cohérents avec la dispersion du gaz observée par ERT : son homogénéité dépend de la concentration en MES et du débit d’air injecté. A forte concentration en MES (6 – 10 g/L), des zones préférentielles de passage des bulles ont été observées, en particulier à faible débit d’air, expliquant ainsi un colmatage plus important. L’utilisation nouvelle dans ce contexte de ces techniques, ERT et logique floue, donne des résultats qui confortent l’intérêt d’adapter l’aération (débit, séquençage) aux caractéristiques des boues notamment leurs concentrations, et qui permettent d’envisager des stratégies de contrôle de ces paramètres / Membrane bioreactors (MBRs) are widely used in the wastewater treatment sector. However, membrane fouling mitigation remains challenging, and leads to important maintenance and energy costs. Several strategies have been developed industrially to enhance MBR productivity, including coarse bubble sequenced aeration for fouling mitigation. The way such aeration participates in sludge hydrodynamic patterns is an important research topic. However, the methods currently used for hydrodynamic characterisation suffer from several drawbacks, mainly due to the system’s complexity (three phases with opaque deformable solids). More research is needed to characterize hydrodynamics in MBRs filled with activated sludge. A semi-industrial reactor (2.0 m3) was designed and equipped with three hollow fiber membrane modules (KMS Puron) to contribute to fill this knowledge gap. The reactor was continuously fed with activated sludge from one of the reactors of the Seine Aval (SIAAP) wastewater treatment plant. Operating parameters, activated sludge properties as well as process performances were monitored for five months with two objectives: (i) to characterize gas dispersion for different operating conditions (aeration strategy, activated sludge concentrations), (ii) to rank activated sludge properties and operating conditions, according to their impact on fouling mitigation. The ultimate goal is to propose adapted aeration strategies allowing sustainable filtration performance. In order to characterize the gas dispersion in a complex geometry such as MBR membrane tanks, an innovative approach based on electrical resistivity tomography was adapted to the pilot conditions. A numerical approach was used to define the experimental design in terms of electrode positions, quadripole sequences but also inversion parameters, used to reconstruct resistivity maps from experimental datasets. This numerical study, performed on COMSOL, demonstrated the ability of the ERT method to observe different patterns in the membrane zone. ERT was therefore applied to characterise bubble dispersion in the semi-industrial membrane bioreactor filled with activated sludge and operated using different aeration conditions. The dataset obtained from filtration monitoring was analysed using fuzzy logic. The resulting fuzzy decision trees, constructed from the whole dataset or from subsets clustering similar operating conditions, pointed out the impact on the permeability evolution of two main factors: the COD difference between activated sludge supernatant and permeate (COD), standing for complex colloidal phase, and Mixed Liquor Suspended Solid (MLSS) concentration. Both variables emphasizing fouling at high values. Also, an air flow rate augmentation seemed to mitigate fouling, except at high COD concentrations (> 500 mg/L), where its impact was reversed. This last observation needs further investigation, on a larger dataset. The model obtained from fuzzy logic allows a better simulation of permeability evolutions compared to multivariate linear regression (errors of 0.61 and 0.70, respectively), despite a relatively high measurement uncertainty of permeability (up to 16 %). Those results are consistent with the gas dispersion observed with ERT measurements: homogeneity of gas dispersion depends on MLSS concentration and air flow rate. At high concentrations of MLSS (6 g/L and 10 g/L), a high air flow rate is required for the bubbles to be distributed on the whole membrane zone and preferential flow paths have been observed, especially at low air flow rate. This gas dispersion heterogeneity explains worsened filtration performance. In this context, the new use of these technics, ERT and fuzzy logic, provided results that reinforce the interest to link aeration parameters to sludge properties, their MLSS concentration in particular, leading to consider control strategies for these operating parameters.
6

Hydroxylation microbienne du méthane au sein d'une nouvelle configuration de bioréacteur à membranes. / Microbial hydroxylation of methane within a new configuration of membrane bioreactor.

Pen, Nakry 26 November 2014 (has links)
Ce travail de thèse a pour objectif le développement et l'optimisation d'une nouvelle configuration de bioréacteur à membranes (BRM) pour l'hydroxylation efficace et sûre du méthane par la bactérie Methylosinus trichosporium OB3b. Ce BRM couple un bioréacteur à deux contacteurs membranaires gaz/liquide macroporeux qui alimentent en continu chaque substrat gazeux (méthane et air) sans générer de bulle dans la suspension bactérienne, évitant ainsi la formation d'un mélange gazeux méthane/air explosif. Dans un premier temps, la faisabilité et la reproductibilité de ce nouveau bioprocédé de conversion du méthane en méthanol ont été démontrées. D'une part, la productivité moyenne obtenue dans ce BRM (75 ± 25 mg méthanol.(g cellules sèches)-1.h-1) est près de deux fois meilleure que celle obtenue dans un réacteur fermé conduit dans les mêmes conditions que le BRM, traduisant un transfert de masse gaz-liquide accru dans le BRM. D'autre part, la productivité obtenue dans ce nouveau BRM est similaire aux meilleures productivités reportées dans la littérature pour des réacteurs alimentés avec un distributeur de gaz à bulles et près de 35 fois meilleure que celle reportée pour le seul autre BRM (à membranes denses) présent dans la littérature. Dans un second temps, le suivi cinétique de l'activité intrinsèque hydroxylante du biocatalyseur a permis de vérifier que l'arrêt de production du méthanol qui est observé après 14 h de réaction correspond à une perte quasi-totale de l'activité du biocatalyseur. Plusieurs essais ont été réalisés pour appréhender les facteurs pouvant avoir une influence sur l'activité hydroxylante de la bactérie, en vue de trouver le moyen d'augmenter le temps de production. Ces essais ont mis en évidence que l'arrêt de production est dû à la fin de vie du biocatalyseur. En parallèle à ces études, dans l'objectif de régénérer le cofacteur NAD nécessaire à la réaction d'hydroxylation de manière économique et in situ, des essais ont été conduits avec un système bio-électrochimique innovant (biocathode) visant à remplacer les électrons d'un donneur d'électrons (formiate) par ceux d'un métal faiblement polarisé. Ces essais ont montré l'incapacité de ces bactéries à utiliser les électrons d'une électrode dans les conditions de la réaction. / This work aimed to develop and optimize a new configuration of membrane bioreactor (MBR) for an efficient and safe methane hydroxylation by the Methylosinus trichosporium OB3b bacterium. This BRM couples a bioreactor with two gas/liquid macroporous membrane contactors supplying continuously each gaseous substrate (methane and air) without generating any bubble in the bacterial suspension, avoiding thus the formation of an explosive methane/air gas mixture. In the first step, the feasibility and the reproducibility of this new bioprocess for the conversion of methane into methanol was demonstrated. In the one hand, the average productivity achieved in the MBR (75 ± 25 mg methanol.(g dry cell)-1.h-1) is twice higher than that obtained in a batch reactor operated with the same conditions, highlighting an increased mass transfer in the MBR. In the other hand, productivity obtained in this MBR is similar to the best productivities reported in the literature for reactors (either fed-batch or continuous) using gas bubble spargers and about 35-times better than the one reported for the only other MBR (with dense membranes) present in the literature. Secondly, a kinetic monitoring of the intrinsic hydroxylating activity of the biocatalyst confirmed that the methanol production stop observed after 14 hours of reaction matched a quasi-total loss of the biocatalyst activity. Several trials were conducted to understand the factors which may influence the bacterial hydroxylating activity, in order to find a way to increase the production time. These trials put in evidence that the production stop is caused by the end of life of the biocatalyst. In parallel to these studies, aiming to regenerate the NAD cofactor required for the reaction by a cheap and in situ way, several tests were conducted with an innovative bio-electrochemical device (biocathode) to replace the electrons from an electron donor (formate) by those from a weakly polarized metal. These trials showed the inability of this bacterium strain to use electrons from an electrode in the conditions of the reaction.
7

Caractérisation et optimisation des phénomènes de transfert dans un double bioréacteur à membranes / Caracterisation and optimization of transfert phenomena in a double membrane bioreactor

Günther, Jan 08 December 2009 (has links)
L'idée de base est de permettre à deux microorganismes de partager le même environnement tout en les maintenant séparées à l'aide d'une membrane perméable les retenant sélectivement. La principale contrainte résulte du transfert des composées d'intérêts limité par l'écoulement dans et autour des fibres ainsi que dans module et par le colmatage. Le double bioréacteur a membrane étudié dans cette thèse, de par son fonctionnement, alterne les cycles de filtration et rétrofiltration (ou rétrolavage), limitant ainsi en partie le colmatage. Ce travail de thèse s'est donc attaché à approfondir la connaissance des mécanismes de limitation au transfert mis en jeu lors de la filtration de fluide biologique complexes et évolutifs en fonction des conditions opératoires et des caractéristiques géométriques du module de filtration à fibres creuses. Dans cet objectif, sur la base des choix de configuration de module membranaire proposés dans cette étude, et afin de tendre vers une optimisation rationnelle de l'utilisation de ce dispositif, l'étude s'appuya sur l'utilisation d'outils de mécanique des fluides numériques, complétée par une approche expérimentale menée dans des conditions modèles. Les simulations réalisées par cette approche ont ainsi mis en évidence de grandes variations des vitesses de filtration le long de la fibre et ceci en lien direct avec une augmentation de la perte de charge à l'extérieur des fibres due au confinement induisant une baisse des performances de filtration. De manière similaire, un modèle numérique de formation de dépôt nous a permis d'évaluer l'effet du confinement de fibres. Il entraine une augmentation de pression dans la partie fluide externe induisant une forte variation de pertes de charges entrainant une répartition du dépôt le long de la fibre beaucoup plus inhomogène. Le retour du numérique à l'expérimental réalisé s'est attaché à décrire l'influence des conditions de mise oeuvre sur les performances de filtration du pilote. L'analyse méthodique de l'influence du sens de filtration et de la compacité dans le cas de fluides modèles (suspension de différents microorganismes / solutions de protéines modèles) et dans le cas de fluides biologiques évolutifs (milieux de fermentation + micro organismes) fut réalisée. L'ensemble de ces résultats nous permettent de donner des recommandations aux futurs utilisateurs du double bioréacteur à membranes. / This work presents a specific bioreactor previously designed to study microbial interactions. In this process, the microbial species in two tanks are physically separated by a microfiltration membrane. In order to give to the microorganisms a molecular environment in each compartment similar to the one that would be obtained if the microbial cells were cultivated in the same reactor, two criteria have to be considered: (i) the flow rates between compartments have to be sufficient with respect to the microbial kinetics and (ii) all the molecular compounds of the medium that have an effect on the microorganism behaviour must pass through the membrane. The main constrain is due to transfer of component limited by the fluid flow in and around the fiber of the filtration module. This thesis has therefore committed to deepening the understanding of the mechanisms limiting the transfer involved during the filtration of biological fluid complex according to operating conditions and geometric characteristics of the hollow fiber module of filtration. For this purpose, based on the choice of membrane module configuration proposed in this study, and to strive for a rational optimization of the use of this device, the study relied on the use of CFD tools, supplemented by an experimental approach conducted under models conditions. The numerical simulations of fluid flow have shown a modification of the axial filtration velocity profile with packing density. Similarly, a numerical model of cake deposit was developed and show difference of cake growth along the fiber with packing density. Two experimental hollow fiber modules with two packing densities were tested with clean water and biological fluid, and showed good agreement with the numerical data. These results underline the variations of filtration velocity along the fiber that will allow some predictions on fouling deposit to be done.
8

Aération pour le décolmatage dans les bioréacteurs à membranes immergées pour le traitement des eaux usées : impact sur le milieu biologique et la filtration / Aeration for fouling limitation in submerged membrane bioreactors for wastewater treatment : impact on biological media and filtration

Braak, Etienne 08 November 2012 (has links)
Cette étude présente les travaux réalisés pour comprendre l'effet de l'aération sur le milieu biologique et sur la filtration dans les bioréacteurs à membranes immergées pour une gamme de paramètres opératoires proche de celles utilisées sur stations réelles. Notre démarche fait le lien entre paramètres opératoires (débit d'aération), hydrodynamique à l'échelle macroscopique (tailles et vitesses de bulles), hydrodynamique à l'échelle locale (contraintes de cisaillement) et propriétés du milieu biologique (taille de flocs et substances polymériques extracellulaires solubles). De moins bonnes performances de filtration à plus forte aération pourraient être expliquées par une plus grande déstructuration des boues sur le court terme. Par ailleurs tout effet d'évolution des boues sur le long terme en fonction des conditions d'aération a été écarté. / This work contributes to the knowledge on aeration for fouling prevention in submerged membrane bioreactors, which represents a great part of energy consumption of the process. More precisely it aims at estimating the impact of aeration on mixed liquor properties for operational parameters range close to those used in full scale plants. Our study links operational parameters (airflow rate), hydrodynamics at macroscopic scale (bubble sizeand velocity), hydrodynamics at local scale (shear stresses), biological media properties (floc size and soluble extracellular polymeric substances), and filtration performance (transmembrane pressure variations). Hydrodynamics characterisation of two phase flow in membrane module enabled to highlight differences between air/water and air/sludge hydrodynamics with 15-25 % lower bubble velocities in sludge but one order of magnitude higher shear stress (maximal values of 10 Pa). Controlled breakdown of biological media was performed by imposing constant shear stress (range 0,1-10 Pa) to mixed liquor samples. Increase of shear induced a decrease of floc size, and soluble extracellular polymeric substances release. The comparison with shear value obtained by simulation showed that stresses induced by aeration were in the range of mixed liquor destructuration. A pilot campaign showed that wastewater had a stronger impact on the long term on mixed liquor properties, and thus filtration performances, than aeration. However higher transmembrane pressure increase rate observed on pilot for higher airflow at similar wastewater quality could be explained by stronger breakage of biological agregates on short term
9

Réutilisation des eaux usées épurées par association de procédés biologiques et membranaires / Urban wastewater reuse by combination of biological and membrane processes

Jacob, Matthieu 19 April 2011 (has links)
Les procédés de réutilisation des eaux usées doivent être robustes, fiables et rentables pour que leur utilisation se démocratise et devienne complémentaire des traitements des eaux de surface. Le couplage d’un procédé biologique et de procédés membranaires représente une solution prometteuse pour répondre à ces challenges. Cette étude se focalise sur l’impact des conditions de fonctionnement du procédé secondaire (en particulier par bioréacteur à membrane BAM) sur le colmatage du procédé tertiaire de nanofiltration (NF) ou d’osmose inverse (OI) ainsi que sur le devenir des micropolluants et microorganismes tout au long de la chaine de traitement. Dans un premier temps, des expériences à court terme de filtration avec différentes membrane NF et d’OI ont été réalisées afin de caractériser les interactions entre effluents secondaires et membranes. Il a ainsi été observé de très fortes rétentions de tous les micropolluants ciblés par la Directive Cadre Européenne. En termes de colmatage, la chute de flux de l’OI, essentiellement liée pour ces essais de courte durée à une augmentation de pression osmotique puis à un dépôt de cristaux minéraux, peut être maîtrisée en contrôlant le pH et la concentration en carbonate et phosphate de l’effluent secondaire. Par ailleurs, des chutes de flux plus importantes sont observées lors des filtrations réalisées avec les membranes de NF qui sont plus sensibles au colmatage irréversible. Dans un second temps, l’optimisation de la filière de traitement des eaux usées urbaines couplant un bioréacteur à membranes à un procédé d’OI a été réalisée à partir d’une unité pilote fonctionnant en continu. La sélection de conditions opératoires adéquates a permis de faire fonctionner le procédé d’OI pendant plus de quatre mois sans qu’aucune maintenance ne soit réalisée. Une faible chute de flux de l’OI, linéaire sur toute la période de filtration, essentiellement dû à l’adsorption de molécules organiques à la surface de la membrane, a été observée. Sur l’ensemble de la période d’essais, la filière BAM/OI permet d’obtenir un abattement optimal en micropolluants présents. Lorsque des micropolluants sont injectés à des concentrations plus élevées (simulation d’une brusque dégradation de la qualité des eaux en entrée de filière) dans le bioréacteur, une chute de l’activité de la biomasse couplée à un relargage de produits microbiens solubles peut être observée. Néanmoins, ces pics de pollution n’ont eu aucun impact sur le colmatage de la membrane du BAM ni sur celle de l’OI. La filière BAM-OI permet donc de garantir un taux de rejet élevé et une productivité d’environ 15 L.h-1.m2 quelles que soient les fluctuations de la composition de l’eau usée urbaine à traiter. / In order to be competitive compare to surface water treatments, wastewater reuse needs robust, reliable and profitable combination of technologies. The combination of bioreactors and membrane processes seems to be a promising solution to these challenges. This study focus on the impact of the operating conditions of the secondary treatment (particularly the membrane bioreactor (MBR)) on the nanofiltration (NF) and reverse osmosis (RO) tertiary treatments as well as the fate of micropollutants and microorganisms along the treatment line. Firstly, short term filtration experiments with various NF and RO membranes were performed in order to characterize the interactions between secondary treatment effluents (STE) and membranes. High retentions of micropollutants listed by the European water framework directive were observed. During these short term experiments, RO flux decline is mainly due to an increase of osmotic pressure and then a precipitation of salts that can be solved by controlling the pH and thus the carbonate and phosphate concentration of the STE. In addition, higher flux declines are observed with NF because of a higher irreversible fouling behavior. Secondly, continuous long term tests were performed on a pilot unit combining a MBR and a RO processes. The appropriate selection of operating conditions allowed treating wastewater during more than four months without any maintenance. A linear low flux decline, mainly due to adsorption of organic molecules at the membrane surface was observed. During this filtration period, the MBR/RO process presented very high micropollutant retentions. When micropollutants are injected at higher concentration (simulation of sudden fluctuation of feed composition) into the MBR, a drop of biomass activity combined with soluble microbial products release can be observed. Nevertheless, these peaks of pollution did not cause any additional fouling of MBR as well as RO membranes. MBR/RO process is then a reliable technology that can guaranty high retention and productivity (around 15 L.h-1.m-2) whatever the fluctuations of the feed composition.

Page generated in 0.0853 seconds