• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 305
  • 112
  • 60
  • 14
  • 11
  • 10
  • 10
  • 10
  • 10
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • Tagged with
  • 606
  • 241
  • 207
  • 162
  • 123
  • 118
  • 103
  • 85
  • 82
  • 80
  • 72
  • 69
  • 58
  • 55
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Influência de materiais bioativos sobre a dureza, ultraestrutura e conteúdo mineral de dentes clareados: estudo in situ / Changes after whitening: bioactive materials benefits- in situ study

Pinheiro, Helena Burlamaqui 03 August 2012 (has links)
Objetivo: Investigar in situ a influência de materiais bioativos sobre a superfície do esmalte e dentina clareados, utilizando o teste de dureza Knoop (KHN), microscópio por emissão de campo (FEG) e quantificação do conteúdo mineral por fluorescência do substrato dental (QLF). Material e Métodos: Vinte molares humanos intactos foram selecionados. Para KHN e FEG, foram necessários 10 dentes. Foram obtidos 6 espécimes da porção cervical de cada dente, contendo esmalte e dentina, e distribuídos entre os 5 grupos experimentais, mais um controle (n=10). O grupo controle (sem tratamento) foi utilizado para o FEG, pois neste tipo de análise há destruição da amostra, não sendo possível a utilização de um mesmo espécime para obtenção de imagens nas fases antes e após o tratamento. Para o teste de dureza, as fatias tiveram os valores iniciais de dureza do esmalte e dentina medidos. Para o QLF, foram usados outros 10 dentes. Cada um foi seccionado em 5 fragmentos de esmalte superficial, retirados da porção coronária de cada dente. Metade de cada espécime foi protegida com verniz e a outra metade serviu para entrar em contato com os diversos tratamentos. Os fragmentos tiveram a quantificação mineral inicial medida pelo QLF. Todos os espécimes foram montados em retentores palatinos intraorais e usados por 10 voluntários durante 24h/dia, por 14 dias. Em cada dispositivo, eram aplicados os 5 diferentes tratamentos: 1: Opal, tratamento clareador com peróxido de carbamida (PC) 15% - Opalescence PF, Ultradent; 2: NiteWhite ACP, PC16% (Philips); 3: Opal + Bio (Biosilicato®, Vitrovita) misturados; 4: Opal Bio (Biosilicato® aplicado por 5 min, 1 vez por semana após clareamento); 5: Opal Rel ACP, Relief ACP (Philips) aplicado por 30 min por dia após clareamento. Em seguida, foram realizadas análises finais de KHN, FEG e QLF. Resultados: A análise estatística revelou que no grupo Opal houve redução significante dos valores de dureza em esmalte. No grupo Opal Bio, a aplicação do material bioativo não foi capaz de evitar a desmineralização do esmalte. Para os demais grupos, não houve alteração dos valores de dureza. Na dentina, o grupo Opal também causou diminuição na dureza. Nos grupos Opal Bio e Opal Rel ACP, a aplicação dos dois materiais bioativos não foi suficiente para evitar diminuição dos valores de dureza em dentina. Já nos grupos NW ACP e Opal + Bio, não foi observada desmineralização desse substrato. Os dados de dureza refletem os resultados observados na análise ultraestrutural do esmalte e da dentina, em que os grupos NW ACP e Opal + Bio apresentaram os melhores desempenhos em relação aos demais grupos. A análise por QLF não apresentou sensibilidade para detectar diferenças estatisticamente significantes entre os grupos e nem entre as fases inicial e final em nenhum dos grupos. Conclusão: No grupo Opal, observa-se desmineralização do esmalte e dentina clareados. A aplicação de Biosilicato® 1x por semana não foi suficiente para evitar alterações em esmalte e dentina. Relief ACP, aplicado diariamente após o tratamento clareador, foi capaz de evitar alterações em esmalte, mas não em dentina. A mistura de um gel clareador com um agente bioativo, como acontece nos grupos NW ACP e Opal + Bio, teve influência positiva em relação à dureza e morfologia da estrutura dental evitando sua desmineralização; nesses dois grupos, foram observados os melhores resultados tanto de dureza, quanto na análise ultraestrutural. / Objective: To Investigate in situ the influence of bioactive materials on whitened enamel and dentin surfaces using Knoop hardness test (KHN), field emission microscope (FEG) and quantitative light-induced fluorescence (QLF). Material and Methods: Twenty intact human molars were selected. Ten teeth for KHN and FEG were used. Six specimens were obtained from the cervical portion of each tooth, containing enamel and dentin. The slices were distributed into five experimental groups and one control (n=10). The control group (no treatment) was used for the FEG images, as this type of analysis destroys the sample, making it impossible to use the same specimens for before and after treatment images. For the hardness test, the enamel and dentin baseline Knoop hardness were measured for each slice for the control group and the five experimental groups. For QLF the other 10 teeth were used, each one sectioned into 5 superficial enamel slices. Half of each specimen was protected with varnish and the other half used to be in contact with the different treatments. The specimens had their baseline mineral content values measured by QLF. All specimens were mounted on intra-oral palatal retainers, which were used by 10 volunteers during 24h/day for 14 days. On each retainer five different treatments were applied: 1: Opal, whitening treatment (WT) with Opalescence PF, 15% carbamide peroxide (CP) (Ultradent); 2: NW ACP, whitening treatment with NiteWhite ACP, 16% CP (Philips); 3: Opal + Bio (Biosilicate®, Vitrovita) mixed; 4: Opal Bio (Biosilicate® applied for 5 minutes once a week after WT; 5: Opal Rel ACP, Relief ACP (Philips) applied 30 min per day after WT. Afterward, further KHN, FEG and QLF analysis were performed. Results: A statistical analyses revealed that the Opal group had a significant enamel hardness decrease. In the Opal Bio group, the application of the bioactive material was not able to prevent enamel demineralization. For the other groups changes in the hardness values were not observed. The Opal group also caused hardness decrease in the dentin. In the Opal Bio and Opal Rel ACP groups the application of the two bioactive materials was not enough to prevent the dentin hardness decrease. In the NW ACP and Opal + Bio groups demineralization of the substrate was not observed. The hardness data reflect the results observed in the ultra structural analysis of enamel and dentin, which groups NW ACP and Opal + Bio showed better performance compared to other groups. The QLF analysis was not sensitive enough to detect statistically significant differences between groups or between the initial and final phases in either groups. Conclusion: Enamel and dentin demineralization was observed for the Opal group. The application of Biosilicato® once a week was not enough to prevent enamel and dentin alterations. Relief ACP, applied daily after the whitening treatment, prevented changes in enamel but not in the dentin samples. The bioactive materials, when incorporated in the whitening gel (NW ACP and Opal + Bio groups), deliver positive benefits for tooth hardness and morphology, preventing demineralization; in both groups better hardness and morphology results were observed.
102

Estudo in vitro da variação do pH de agentes clareadores e seu efeito sobre o desgaste e rugosidade superficial do esmalte bovino após escovação simulada / Variation of pH bleaching gels, wear and roughness of bovine enamel after tooth brushing abrasion test.

Trentino, Ana Carolina 20 May 2011 (has links)
Este estudo in vitro avaliou a variação do pH de géis clareadores à base de peróxido de hidrogênio de diferentes concentrações e seu efeito sobre o esmalte bovino submetido à escovação simulada. Fragmentos de esmalte de dentes bovinos com 1,5cm x 0,5cm x 0,4cm, receberam o tratamento clareador e a escovação em uma metade, ficando a outra como controle; foram divididos aleatoriamente em nove grupos (n=10): G1 = controle; G2 = Whiteness HP 35% - 3 sessões (3x15); G3 = Whiteness HP 35% - 3 sessões (1x45); G4 = Lase Peroxide 35% - 1 sessão (4x730) + ativação com luz híbrida LED/Laser; G5 = Lase Peroxide 25% - 1 sessão (4x730) + ativação com luz híbrida LED/Laser; G6 = Lase Peroxide 15% - 1 sessão (4x730) + ativação com luz híbrida LED/Laser; G7 = Whitegold Office 35% - 3 sessões (1x45); G8 = Whiteness HP Blue Calcium 35% - 3 sessões (1x40); G9 = Whiteness HP Blue Calcium 20% - 3 sessões (1x50). A rugosidade aritmética (Ra) inicial, após clareamento e após escovação foi determinada pela média (µm) de 3 leituras com o rugosímetro Hommel Tester T 1000. Os valores de pH foram determinados pelo peagômetro digital Sentron Model 1001 nos tempos inicial e final independente do número de aplicações ou de sessões. Os espécimes foram armazenados em saliva artificial por 7 dias, submetidos à 100.000 ciclos de escovação simulada. Após 24 horas o desgaste superficial foi determinado (µm) novamente com o rugosímetro Hommel Tester T1000. Os dados da análise de pH foram submetidos a ANOVA um critério e teste de Tukey (p<0,05) com diferenças estatísticas. O teste de Kruskal Wallis e Dunn (p<0,05) aplicado sobre a variação da rugosidade e desgaste apontou diferenças estatísticas entre os grupos. Os géis clareadores apresentaram uma tendência de diminuição dos valores de pH do tempo inicial para o tempo final. Os géis clareadores apresentaram um tendência de diminuição dos valores de pH do tempo inicial para o tempo final, assim como os géis com valores de pH mais próximos dos valores ácidos tendem a levar a superfície do esmalte à uma maior susceptibilidade ao aumento da rugosidade e desgaste superficial, quando submetido à escovação simulada. / This in vitro study evaluated the variation of the pH of bleaching gels, roughness and the wear on bovine enamel, after various in office bleaching protocols and brushing. Ninety fragments of enamel, measuring 15mm x 5mm, were randomly divided into nine groups (n=10) according to bleaching procedure: G1: control; G2: 35% hydrogen peroxide (HP) (Whiteness HP, FGM) 3x15, 3 sessions with one week between each; G3: 35% HP (Whiteness HP, FGM) 1x45, in 3 sessions; G4: 35% HP (Lase Peroxide, DMC) + hybrid light (HL) (LED/Diode laser, Whitening Lase II, DMC Equipments), 4x730 (6 of HL activation), in 1 session; G5: 25% HP (Lase Peroxide II, DMC) + HL, 4x730 (6 of HL activation), in 1 session; G6: 15% HP (Lase Peroxide Light, DMC) 4x730 (6 of HL activation), in 1 session; G7: 35% HP (Whitegold Office, Dentsply) 3x15, in 3 sessions; G8: 35% HP (Whiteness HP Blue Calcium, FGM) 1x40, in 3 sessions; G9: 20% HP (Whiteness HP Blue Calcium, FGM) 1x50, in 3 sessions. The pH values were determined using a pH meter (Sentron Model 1001, Sentron) during the initial and final gel application times. The surface roughness (Ra) was evaluated with a rugosimeter (Hommel Tester T 1000) before and after bleaching, and after brushing (100,000 strokes). The rugosimeter was used to evaluate wear surface after 24 hours brushing. The data were submitted to one-way ANOVA and Tukey tests for pH values, Kruskall Wallis and Dunns test in relation to wear and surface roughness (p<0.05). It could be concluded that the pH values tended to decrease from the initial to final bleaching. After tooth brushing, bleaching procedures with highly acidic products provided a significant increase in enamel wear and surface roughness.
103

Intelligent-Illumination STED

Heine, Jörn 18 December 2017 (has links)
No description available.
104

Efeitos da solução de alfatocoferol na resistência à fratura, resistência de união e na interface adesiva na dentina de dentes tratados endodonticamente submetidos ao clareamento dental com peróxido de hidrogênio /

Albaricci, Maria Carolina da Costa January 2019 (has links)
Orientador: Andréa Abi Rached Dantas / Resumo: Após o clareamento dental, radicais livres permanecem na estrutura dental interferindo negativamente na adesão, além disso também geram redução da resistência dental à fratura. Sugere-se que substâncias antioxidantes podem ser capazes de reverter tais efeitos. Assim, esse estudo buscou avaliar os efeitos da solução de alfatocoferol em diferentes concentrações sobre a resistência à fratura, formação de camada híbrida e resistência de união adesiva de dentes tratados endodonticamente e clareados. Foram realizados 3 experimentos. Experimento 1: 60 incisivos bovinos receberam tratamento endodôntico e foram distribuídos em 6 grupos (n=10): G1 - coroas apenas restauradas; G2 - coroas clareadas e restauradas; G3 - coroas clareadas e aplicação de solução de ascorbato de sódio 10%; G4 ao G6: coroas clareadas e aplicação das soluções de alfatocoferol nas concentrações de 15%, 20% e 25%, respectivamente. Os espécimes foram submetidos ao teste de resistência à fratura em máquina de ensaios mecânicos (EMIC). Experimento 2: 60 incisivos bovinos foram tratados endodonticamente, distribuídos e tratados, de acordo com o grupo, de forma idêntica ao experimento 1. Os espécimes foram seccionados na junção cemento-esmalte e no sentido vestíbulo-lingual, lixados e polidos, passaram por processo de desproteinização com ácido clorídrico 18% e hipoclorito de sódio 5%. Em seguida, foram moldados com silicona de adição e vasados com resina epóxi. Os modelos obtidos foram analisados em microscópio eletr... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: After dental bleaching, free radicals remain at the dentin, which causes reduces at adhesive and fracture resistance. To minimize these undesirable effects, the use of antioxidants to neutralize free radicals before the final restoration is recommended. This study evaluated the effects of alphatocopherol solution at different concentrations on the fracture resistance, hybrid layer and shear bond strength of endodontically treated teeth subjected to tooth bleaching. Three experiments were done. Experiment 1: 60 bovine incisors were endodontically treated and then divided into 6 groups (n=10): G1 - the teeth immediately restored with composite resin; G2 - the teeth were bleached and immediately restored; G3 - the teeth received treatment similar to that used for G2, but with 10% sodium ascorbate gel applied after the bleaching protocol; G4 to G6: the teeth received treatment similar to that used for G3, rather than sodium ascorbate, it was applied alphatocopherol at concentrations of 15%, 20% and 25%, respectively. Teeth were subjected to a fracture resistance test in an electromechanical testing machine (EMIC). Experiment 2: 60 bovine incisors were endodontically treated, distributed and treated identically to experiment 1. The specimens were sectioned at the cementum-enamel junction and in the vestibular-lingual direction, sanded and polished, and then it was made the deproteinization with 18% hydrochloric acid and 5% sodium hypochlorite. Then, they were molded with addition / Mestre
105

Avaliação clínica da sensibilidade e efetividade do clareamento em consultório de dentes polpados, com e sem o emprego de fonte de luz: controle de 12 meses / Clinical evaluation of sensitivity and effectiveness of in-office whitening in sounds teeth, with and without the use of light source: 12 months follow-up

Rosa, Enio Ratton 14 May 2012 (has links)
Este estudo in vivo analisou comparativamente duas técnicas de clareamento de dentes polpados, quanto ao grau de sensibilidade, mudança de cor e estabilidade do tratamento num período de doze meses. Dez pacientes foram selecionados de acordo com os critérios de inclusão e exclusão, e submetidos ao clareamento em consultório, sendo que o mesmo paciente recebeu os dois protocolos de clareamento. Grupo A (GA): três aplicações de 15 (totalizando 45) do gel de peróxido de hidrogênio (PH) 35% (Lase Peroxide Sensy, DMC Equipamentos Ltda.), nos hemi-arcos inferior e superior esquerdo. Grupo B (GB): três aplicações do gel PH 35% ativado com luz híbrida de LED/laser de diodo (Whitening Lase II DMC Equipamentos Ltda.) por 2, com intervalo de 30 (730), totalizando 2230, nos hemi-arcos inferior e superior direito. A avaliação da cor foi realizada com o espectrofotômetro Vita EasyShade (VITA), sendo a diferença mensurada através do sistema CIE-Lab antes do clareamento, após 24 horas, 1 semana, 6 e 12 meses. A sensibilidade dentária foi avaliada por meio do questionário VAS antes, imediatamente após o clareamento, após 24 horas e 1 semana. Para as variáveis luminosidade (?L) e alteração de cor (?E), ANOVA a dois critérios (período e luz) revelou haver diferenças estatisticamente significantes intra e intergrupos em função dos períodos avaliados (p<0,001). O teste de Tukey (p<0,001) para comparações individuais apontou diferenças significantes intergrupos para os dentes superiores nos períodos de 1 mês, 6 meses e 1 ano com os demais tempos avaliados. Para os dentes inferiores não houve diferenças estatísticas intra e intergrupos (p=0.0821). O GB ativado com luz apresentou, imediatamente após o clareamento, o menor grau de sensibilidade dentária com diferença estatística (p=0,043) em comparação ao GA (sem luz). Os dois protocolos de clareamento com e sem luz avaliados durante 12 meses foram semelhantes quanto a efetividade do clareamento dental. Por outro lado, a utilização da fonte de luz híbrida diminuiu o tempo de tratamento em 50% e proporcionou menor grau de sensibilidade pós-operatória. / This study examined in vivo comparison of two techniques for whitening pulp teeth, the degree of sensitivity, color change and stability of treatment over a period of twelve months. Ten patients were selected according to the criteria for inclusion and exclusion, and subjected to in-office bleaching, and the same patient received both protocols whitening. Group A (GA): three applications of 15\' (total 45\') of hydrogen peroxide gel (PH) 35% (Sensy Lase Peroxide, DMC Equipment Ltd.), Hemi-arches in the lower and upper left. Group B (GB): three applications of the gel 35% PH with light activated hybrid LED / laser diode (Whitening Lase II DMC Equipments Ltda.) By 2 \', with an interval of 30\' (7\'30\"), totaling 22\'30\", hemi-arches in the lower and upper right. The evaluation was performed color with the spectrophotometer Vita Easyshade (VITA), and the difference measured with the CIE-Lab system before the treatment, after 24 hours, 1 week, 6 and 12 months. The tooth sensitivity was assessed using the VAS questionnaire before and immediately after bleaching, after 24 hours and 1 week. For the variable brightness (?L) and color change (?E), two-way ANOVA (time and light) revealed statistically significant differences within and between groups on the basis of the evaluation period (p<0.001). The Tukey test (p<0.001) for individual comparisons showed significant differences between groups for the upper teeth at 1 month, 6 months and 1 year with the other times evaluated. For the lower teeth no statistical differences within and between groups (p=0.0821). The GB had activated with light, immediately after bleaching, the lowest degree of tooth sensitivity with statistical difference (p=0.043) compared to GA (no light). The two protocols with and without light bleaching evaluated during 12 months were similar in effectiveness of tooth whitening. Moreover, the use of the light source hybrid decreases the time of treatment provided by 50% and less sensitivity postoperative.
106

Avaliação clínica de diferentes técnicas de clareamento de dentes polpados quanto à efetividade durante 12 meses / Clinical evaluation of effectiveness for different techniques of extrinsic bleaching

Azevedo, Juliana Felippi David e Goés de 30 September 2009 (has links)
Objetivos: Este estudo in vivo avaliou comparativamente diferentes técnicas de clareamento de dentes polpados, quanto ao grau de mudança de cor e estabilidade do tratamento num período de doze meses, sensibilidade dentinária e o condicionamento ácido prévio ao clareamento. Métodos: Quarenta e cinco voluntários foram selecionados, de acordo com os critérios de inclusão e exclusão, e divididos aleatoriamente em 5 grupos (n=15). No clareamento em consultório, apenas na hemi-arcada direita (inferior e superior), o gel clareador foi ativado com uma fonte de luz híbrida enquanto no outro lado o gel não foi ativado, assim um mesmo voluntário participou de dois grupos. Além disso, um primeiro pré-molar superior direito ou esquerdo foi condicionado previamente ao clareamento com ácido fosfórico a 37% durante 15s. G1- Lase Peroxide (DMC Equipamentos), a base de peróxido de hidrogênio (PH) a 35% + duas ativações do gel com luz híbrida (LED e Laser de Diodo) (Whitening Lase II DMC Equipamentos) por três minutos e intervalo de 1min; em três aplicações; G2- Lase Peroxide em três aplicações de 15min e intervalos de 15mim; G3 - Opalescence Xtra Boost (Ultradent), a base de PH a 38% + duas ativações do gel com luz híbrida por três minutos e intervalo de 1min; em três aplicações; G4- Opalescence Xtra Boost em três aplicações de 15min e intervalos de 15mim; G5 - Opalescence PF (Ultradent), a base de peróxido de carbamida (PC) a 15%, 2 horas diárias por 10 dias. A avaliação da cor quantitativamente foi realizada com o espectofotômetro Vita EasyShade (Vita), antes do clareamento e após 24horas, 1 semana, 6 e 12 meses. A diferença de cor (_E) foi mensurada através do programa CIELab. A sensibilidade dentinária foi avaliada por meio do questionário VAS antes, imediatamente após o clareamento, 24 horas e uma semana. Resultados: A análise estatística não revelou nenhuma diferença estatística significante entre os grupos com e sem ativação do gel com luz híbrida. Diferença estatística foi observada entre os resultados após 24h, 1 semana e 1, 6 e 12 meses para todos os grupos experimentais. O clareamento em consultório utilizando o Lase Peroxide mostrou um aumento significante na sensibilidade quando comparado com o clareamento caseiro. O Lase Peroxida utilizado com luz híbrida e condicionamento prévio do esmalte demonstrou aumento significante da alteração de cor. Conclusão: Pode-se concluir que todas as técnicas e agentes clareadores usados são efetivos no clareamento dental. O uso de condicionamento ácido prévio ao clareamento aumenta o grau clareamento dos dentes. / Objectives: This study was evaluated color change and stability and tooth sensitivity in patients submitted to different bleaching techniques. Methods: Forty five patients were selected according to inclusion/exclusion criteria and divided in five groups (n=15). A half-mouth design was conducted to compare two in-office bleaching techniques with the same product and the effect of acid condition before treatment. G1: 35% hydrogen peroxide (HP) (Lase Peroxide, DMC Equipments) + hybrid light (LED + Diode Laser) Whitening Lase II (DMC equipments); G2: 35%HP; G3: 38%HP, X-tra Boost (Ultradent) + hybrid light; G4: 38%HP and G5: 20% Carbamide Peroxide (PC), Opalescence PF (Ultradent). For G1 and G2, PH was applied on the enamel surface for three consecutive times and activated by hybrid light during 6 min; G2 and G4, PH was applied on the enamel surface for three consecutive times during 15min and interval of 15min; G5, 15% PC for 2 hours daily during 10 days at home. The spectrophotometer VITA Easyshade (VITA) was used for color change, before the treatment and 24h, 1 week, 1, 6 and 12 months after. Color differences (_E) were assessed by means of the CIELab Program. VAS questioner was used for sensitivity tooth before the treatment and immediately, 24h and 1 week after. Results: The statistical analysis did not reveal any significant difference between activated or not by hybrid light. Statistical difference was observed between the results after 24h, 1 week and 1, 6 and 12 months, for both experimental groups. In-office bleaching with Lase Peroxide showed significant increase tooth sensitivity compared to home bleaching. Lase Peroxide with hybrid light and acid condition showed a significant increase in color change. Conclusion: It could be concluded that all the techniques and bleaching agents used are effective for dental bleaching. The use of acid condition before bleaching increase color chance.
107

Avaliação difratográfica da microestrutura de três resinas compostas submetidas à aplicação de um agente clareador a base de peróxido de hidrogênio / Difractiography evaluation of three dental composites subjected to a bleaching agent-based hydrogen peroxide

Rodrigo Rocha Maia 26 March 2008 (has links)
A odontologia moderna utiliza métodos e técnicas ultraconservadores no intuito de corrigir os diversos tipos de alterações cromáticas observadas clinicamente. Os meios empregados baseiam-se na utilização de substâncias químicas à base de peróxidos presentes em diversas concentrações. O presente estudo objetivou avaliar a microestrutura de três resinas compostas fotossensíveis submetidas à aplicação de um agente clareador a base de peróxido de hidrogênio a 35% (Whiteness HP Maxx - fabricante: FGM), ativado por uma fonte híbrida de energia luminosa (Aparelho de Laser-Led Whitening Lase, fabricante: DMC). Para isso, foram confeccionados 30 corpos de prova (CDP) 10 para cada grupo, no formato de discos, com 13 mm de diâmetro e 2,0 mm de espessura em uma matriz de teflon e aço inox, fotoativados por um aparelho de luz halógena convencional (Optilux 401 - Demetron/UR) por 40 segundos com densidade de potência média igual a 450 mW/cm2. Os grupos foram dispostos da seguinte forma: Grupo 1 - resina microparticulada (Durafill VS - fabricante: Heraeus Kulzer); Grupo 2 - resina micro-híbrida (Esthet-X - fabricante: Dentsply); e Grupo 3 resina nanoparticulada (Filtek Supreme XT fabricante: 3M ESPE). Todos os materiais restauradores utilizados eram da cor A2. Após serem submetidos à sequência de acabamento e polimento os CDP foram armazenados por sete dias em saliva artificial, limpos em ultra-som, envelhecidos artificialmente de acordo com a norma ASTM G 154. Os CDP dos três grupos foram aleatoriamente divididos em 2 subgrupos (ST sem tratamento e CT com tratamento) e finalmente submetidos aos experimentos. Os CDP dos subgrupos 1-ST, 2- ST e 3-ST foram triturados (SPEX SamplePrep 8000-series, marca: Mixer/Mills) seguido pela verificação dos materiais por meio de um espectrômetro (marca/modelo: Shimadzu EDX 720) para certificação da ausência de elementos pertencentes ao meio de moagem e por fim foram levados a um difrator de raios-X (marca / modelo: Philips -PW 3040 -X'Celerator- 40kV; 30mA; (&#955;): CuK&#945;; 0,6; 0,2mm; 0,05 (2&#952;); 2s; 10-90 (2&#952;). Em seguida os CDP dos subgrupos 1-CT, 2- CT e 3-CT foram tratados com o peróxido de hidrogênio de acordo com o protocolo do fabricante para a fonte híbrida luminosa de energia selecionada, totalizando 9 aplicações de 10 minutos, onde eram respeitados os tempos de 3 minutos de ativação por 20 segundos de descanso, finalizando 10 minutos em cada aplicação. Mediante a este tratamento, os CDP dos subgrupos CT eram verificados e avaliados pelo mesmo método descrito anteriormente. Após interpretação gráfica, análise comparativa por meio do processamento digital das imagens no programa KS400 3.0 (Carl Zeiss Vision) e análise de concordância por cinco avaliadores calibrados utilizando um escore, pôde-se concluir que houve degradação estrutural e que as estruturas cristalinas das resinas estudadas foram afetadas de forma distinta quando tratadas pelo peróxido de hidrogênio; onde observou-se que: Grupo 1 > Grupo 3 > Grupo 2. Foi sugerido a realização de novos estudos, relacionados à interação do peróxido de hidrogênio às resinas compostas. / Currently, to correct dental chromatic alterations, the modern dentistry science takes advantage of ultraconservative's techniques and methods. Chemical substances, in particular peroxides are used in various concentrations. The purpose of this study was to evaluate the microstructure of 3 composites resin submitted the applies of a whitening gel - hydrogen peroxide 35% (Whiteness HP Maxx, FGM) activated by a hybrid energy light (Laser-Led, Whitening Lase, DMC). Thirty composite discs (13 mm diameter x 2,0 mm thickness) were made in a teflon custom matrix and assigned to the following groups: Group 1, microfill resin (Durafill VS, Heraeus-Kulzer); Group 2, micro hybrid resin (Esthet-X, Dentsply) and Group 3, nanofill resin (Filtek Supreme XT, 3M ESPE). Samples were light cured with an Optilux 401 (Demetron/UR) for 40s by irradiation powers about 450 mW/cm2. All samples were prepared using shade A2, followed by finishing and polishing procedures. Then, samples were stored in artificial saliva for seven days, ultra-sonicated and submitted an artificial aged (ASTM G 154). After that, each group was randomly divided in two sub-groups: ST Without treatment and CT- With treatment. The ST samples of groups 1, 2 and 3 were triturate using a grinder (SPEX SamplePrep 8000-series, Mixer/Mills), and then the materials were evaluated with a spectroscopy microscope (Shimadzu EDX 720) to verify the absence of milling particles, and a X-ray diffraction patterns were recorded using Philips - PW 3040 -X'Celerator- 40kV; 30mA; (&#955;): CuK&#945;; 0,6; 0,2mm; 0,05 (2&#952;); 2s; 10-90 (2&#952;).The CT samples of group 1, 2 and 3 were treated with hydrogen peroxide following the manufacturer protocols 9 sequential 10 minutes applications/time, totaling 90 minutes. Triturated and evaluated using the same method described above. Comparative analysis by means of image processing software KS400 3.0 (Carl Zeiss Vision), graphic interpretation and agreement analysis by five valuators calibrated using a score of the results shown degree of crystallinity of the tested composites changed by bleaching treatment. After a comparative analysis, Group 1 demonstrated more degradation followed by group 3 and group 2. New studies are necessary to define the exact interaction between composite resin and hydrogen peroxides.
108

Avaliação in vitro da alteração de cor e da temperatura dentinária de dentes bovinos, em procedimentos de clareamento sobre o esmalte, utilizando três fontes de luz. Análise morfológica da superfície de esmalte / In vitro temperature, color and surface morphology analyses of bovine teeth during bleaching procedure with three light sources

Freitas, Ana Carolina Pedreira de 01 June 2007 (has links)
O objetivo deste estudo foi analisar in vitro a alteração de temperatura da dentina, alteração de cor na superfície de esmalte e possíveis alterações na morfologia superficial dos dentes durante procedimentos de clareamento. Amostras de dentes bovinos com a espessura padronizada (1,0mm de esmalte e 1,0mm de dentina) foram preparadas e manchadas com chá preto antes de serem submetidas a diferentes tratamentos: peróxido de hidrogênio 35%, gel placebo ou nenhum gel foram aplicados sem ou com a ativação de luz LED, luz halógena ou laser de argônio. As fontes de luz foram aplicadas durante 30 segundos sobre o esmalte e a temperatura foi mensurada na face de dentina com um termômetro de radiação infravermelha. Aferições da cor foram realizadas na superfície de esmalte de acordo com o sistema CIEL*a*b* antes e após o manchamento, assim como imediatamente, 24 horas e 1 semana após os tratamentos. Possíveis alterações na superfície de esmalte foram analisadas em microscópio eletrônico de varredura. Na maioria dos grupos, o pico de temperatura da dentina ocorreu aos 50 segundos. A luz halógena foi a fonte de luz que gerou maior aumento de temperatura. Alterações significativas na claridade foram observadas quando o peróxido de hidrogênio 35% foi utilizado com ou sem a aplicação de uma fonte de luz. Nenhum dos grupos estudados mostrou alterações morfológicas significativas na superfície de esmalte. O tratamento clareador de consultório mostrou ser eficiente com ou sem a aplicação de luz e as técnicas de tratamento estudadas não foram capazes de causar alteração morfológica na superfície de esmalte. / The purpose of this in vitro study was to examine the effects of different bleaching procedures on dentin temperature rise, enamel color alteration and surface morphology of teeth. Bovine tooth samples of standardized thickness (2,0mm with similar dentin and enamel thickness) were prepared and stained with black tea before being submitted to different treatments: in-office bleaching using 35% hydrogen peroxide, placebo gel or no gel application with or without LED, halogen or argon laser light activation. The light sources were applied during 30 seconds above enamel surface, and the temperature rise was measured on dentin surface with an infrared thermometer. Colorimetric measurements were performed on enamel surface, according to the CIEL*a*b* system, before and after staining as well as after the treatments (immediately, 24 hours and 1 week later). Enamel surface alterations in the bleached and unbleached teeth were studied using a scanning electron microscope. Most groups presented the dentin highest temperature at 50 seconds. The halogen light induced significantly higher temperature increases than any other curing unit. Significant differences in lightness value were obtained for the 35% hydrogen peroxide agent with all light sources or without a light source. None of the teeth studied showed detectable surface changes in the subsequent SEM (2000X) analysis of the enamel surface. In-office bleaching procedure is efficient with or without the application of a light source and the studied treatment techniques did not create any detectable enamel surface changes.
109

Impact of environmental changes on Oculina patagonica coral holobiont / Impacto de los cambios ambientales en el holobionte del coral Oculina patagonica

Rubio-Portillo, Esther 27 March 2015 (has links)
No description available.
110

The evaluation of the effect of acid etching and the use of a base during intra-coronal bleaching using thiourea and hydrogen peroxide on blood-stained root-filled teeth / Fabrizio Damiani.

Damiani, Fabrizio. January 2005 (has links)
"October, 2005" / Coursework / Bibliography: leaves 97-105. / xvi, 136 leaves : / Title page, contents and abstract only. The complete thesis in print form is available from the University Library. / Thesis (D.Clin.Dent.)--University of Adelaide, Dental School (Endodontics), 2005

Page generated in 0.1194 seconds