• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 352
  • 13
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 373
  • 151
  • 115
  • 94
  • 93
  • 89
  • 72
  • 57
  • 57
  • 55
  • 50
  • 46
  • 46
  • 42
  • 40
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

Simulação numérica de blocos e prismas de alvenaria em situação de incêndio / Numerical simulation of masonry blocks and prisms under fire situation

Rodovalho, Francielle da Silva 23 May 2018 (has links)
A alvenaria estrutural é um sistema construtivo muito antigo no qual as paredes exercem função estrutural além da função de vedação. Este sistema construtivo é muito utilizado no Brasil, entretanto, poucas pesquisas foram realizadas sobre o seu comportamento em situação de incêndio e o país ainda não possui métodos normativos de dimensionamento de alvenaria estrutural em situação de incêndio. Assim, o objetivo deste trabalho foi verificar o desempenho da alvenaria estrutural com blocos de concreto submetida a elevadas temperaturas através da simulação de prismas. No software Abaqus foram simulados o comportamento do bloco e prisma sujeitos à compressão em temperatura ambiente e do prisma em situação de incêndio com diferentes condições de contorno. O comportamento do bloco e prisma sujeitos à compressão e em temperatura ambiente foi validado até a carga última. As elevações de temperatura das faces não expostas ao fogo ficaram bem representadas por meio das simulações térmicas. A perda de resistência dos materiais foi adotada conforme a literatura técnica nas simulações termomecânicas. Através do que foi analisado no trabalho observou-se que os prismas se comportam bem quanto ao isolamento térmico em situação de incêndio, principalmente aquele com revestimento em argamassa nas duas faces. Quanto ao critério de resistência mecânica os resultados numéricos não foram validados com experimentais, entretanto, foi possível representar a deterioração térmica dos materiais. / The structural masonry is a very old building system in which the walls have structural and partition function. The use of this building system is widely spread in Brazil, however, few research programs were carried out on their behavior under fire situation and the country has not yet developed standard normative methods for designing structural masonry subject to fire. Thus the purpose of this research was to verify the performance of concrete blockwork structural masonry submitted to high temperatures through the simulation of prisms. In the Abaqus software the behavior of block and prism subjected to compression at room temperature and of the prism under fire situation with different boundary conditions were simulated. The compression of the block and prism at room temperature was validated until ultimate loads. The temperature rises of the non-exposed faces were well represented through thermal simulations. The material\'s resistance loss was adopted according to the technical literature in the thermomechanical simulations. Based on the analyzed examples it was observed that the prisms behave well regarding the thermal insulation under fire situation, mainly when having mortar coating on both sides. Regarding the mechanical resistance criterion, the numeric results were not validated with experimental ones, however, it was possible to represent the thermal deterioration of the materials.
272

Estudo da resistência e da deformabilidade da alvenaria de blocos de concreto submetida a esforços de compressão / Study of strength and curved stress/strain relationship of blockwork masonry walls under compression

Juste, Andrea Elizabeth 03 August 2001 (has links)
O estudo da resistência à compressão e da deformabilidade de paredes de alvenaria de blocos de concreto é de fundamental importância para a caracterização desse material e o desenvolvimento de análises de estruturas compostas por esse tipo de painel. Este trabalho trata desse tema, objetivando prever com maior acuidade os principais parâmetros de deformação e de resistência de paredes de alvenaria de blocos de concreto, a saber: resistência à compressão e módulo de elasticidade longitudinal nas direções paralela e perpendicular à junta de assentamento. Foi desenvolvido um trabalho experimental para estimar a influência da resistência dos blocos, da resistência da argamassa e da direção de aplicação de forças no comportamento mecânico da alvenaria de blocos de concreto não-grauteada, quando submetida a esforços de compressão. Para tanto, realizaram-se ensaios de laboratório em blocos, argamassas, prismas de três blocos e paredinhas com dimensões de 80 cm x 80 cm. Por inferência estatística não foram obtidas correlações aceitáveis entre as variáveis estudadas. Porém, obtiveram-se tendências de comportamento dos corpos de prova estudados, confirmando a influência das características da argamassa e do bloco no comportamento estrutural da alvenaria quando submetida a esforços de compressão / The study of strength and the curved stress/strain relationship of blockwork masonry walls is basic for the material characterization and the development of structural analysis of blockwork walls. This work deals with that subject, aiming at the evaluation of the main elastic parameters and the strength of concrete blockwork walls: the compressive strength and modulus of elasticity for masonry in two orthogonal directions, parallel and perpendicular to bed joints. An experimental program was developed to evaluate the influence of the strength of blocks and mortar, and the load application direction on the mechanical behavior of ungrouted concrete block masonry under compression. A series of laboratory tests was carried out with blocks, mortar, prisms of three blocks and wallets (80 cm x 80 cm). It was impossible to obtain acceptable correlations of the defined variables, using statistical inference. However, tendencies of the specimens behavior were obtained, confirming the influence of mortar and block properties on the structural behavior of concrete blockwork walls under compression
273

Análise do desempenho estrutural e hidráulico de um pavimento permeável com revestimento de blocos de concreto unidirecionalmente articulados. / Hydraulic and structural performance analysis of a permeable pavement with articulated concrete block surface layer.

Ono, Bruno Watanabe 13 March 2018 (has links)
O emprego de pavimentos permeáveis tem se tornado cada vez mais necessário como medida compensatória para amortecer as vazões de pico e atenuar os impactos gerados pelas chuvas torrenciais em áreas altamente urbanizadas. Dentre os materiais convencionalmente adotados como revestimento permeável no contexto nacional destacam-se os blocos de concreto intertravados (BCI) e o asfalto poroso. No entanto, internacionalmente, existem materiais alternativos que podem apresentar permeabilidade igual ou até mesmo superior. Sob esse prisma, convém destacar o uso dos blocos de concreto articulados (BCA), recentemente adotados nos Estados Unidos e na Coréia do Sul, cuja capacidade de infiltração vem mostrando-se bastante promissora. Diferentemente dos blocos intertravados, os BCA foram projetados para trabalhar em conjunto, já que são interconectados por meio do encaixe das articulações unidirecionais de cada peça, sobrepostas umas às outras, dispensando assim o uso de material de rejunte, o que por sua vez aumenta a permeabilidade do revestimento. Contudo, embora o desempenho hidráulico aparente ser eficaz, questiona-se se o pavimento de blocos de concreto articulados (PBCA) comporta-se de forma igualmente satisfatória em termos estruturais. Nesse sentido, visando avaliar o desempenho estrutural e hidráulico de um pavimento permeável de BCA, foi construída uma pista experimental (20 x 5 m) no Campus da USP, adotando-se dois tipos de base, uma de agregado reciclado (RCD) e outra de agregado natural (brita 1). Na análise estrutural utilizaram-se como parâmetros de avaliação as deflexões máximas obtidas via FWD (Falling Weight Deflectometer), a eficiência de transferência de carga (LTE - Load Transfer Efficiency) e por fim, os módulos de resiliência retroanalisados para cada camada. Ademais, a pesquisa ainda avaliou a influência da presença de fissuras ou trincas nos blocos no desempenho estrutural do pavimento, já que acabaram tornando-se recorrentes em ambas as seções avaliadas. Já na avaliação hidráulica, monitorou-se a taxa de infiltração in situ ao longo de quase vinte meses. Complementarmente, foram realizadas ainda avaliações laboratoriais dos materiais empregados e funcionais do pavimento. A análise estrutural indicou que o sentido articulado do BCA obteve respostas estruturais nitidamente melhores que o sentido não articulado em termos de módulo de resiliência, deflexões máximas e LTE, evidenciando que de fato as articulações conferem intertravamento ao pavimento, próximo ao propiciado pela areia de rejunte no BCI. A base de RCD por apresentar uma distribuição granulométrica mais bem distribuída do que a brita 1, também obteve melhores resultados. Já a presença de trincas ou fissuras nos blocos não acarretou comprometimento no desempenho estrutural da pista experimental, devido ao baixo grau de severidade da maioria das patologias encontradas, como atestou o levantamento funcional, cuja classificação indicou um pavimento em boas condições de serventia. No que diz respeito ao desempenho hidráulico, o pavimento apresentou um desempenho adequado em termos de capacidade de infiltração. Apesar da perda progressiva estimada em 20% ao ano, as taxas de infiltração in situ mantiveram-se acima de 10-3 m/s em todos os ensaios realizados, sendo, portanto, superior à maioria dos revestimentos permeáveis tradicionalmente utilizados como os blocos intertravados e a camada porosa de atrito, conforme descritos pela literatura. / Pervious pavements have become increasingly fundamental as a compensatory measure to attenuate peak flows and to mitigate the impacts generated by torrential storm water in highly urbanized areas. Among the usual materials applied in permeable surface layers, it is possible to highlight the interlocking concrete blocks (ICB) and the porous asphalt. However, internationally, there are alternative materials that are able to present a higher permeability. In this sense, the use of articulated concrete blocks (ACB) needs to be stressed. Recently adopted in United States of America and South Korea, ACB has presented promising infiltration rates. Unlike the ICB, the ACB was designed to work as an integrated framework due to the presence of articulated joints in one of the block directions, which allows discarding the jointing sand and as result, increases water infiltration. Nevertheless, although the pavement hydraulic performance seems to be successful, there are some doubts about the structural behavior. Thereby, aiming at evaluating the hydraulic and structural performance of an unidirectionally articulated concrete block pavement, a pavement experimental section (20 x 5 meters) was constructed at the University of São Paulo Campus. Two types of different bases were applied, namely recycled concrete aggregate (RCA) and natural aggregate. The structural assessment took into account the maximum deflection measurements, the load transfer efficiency (LTE) and the backcalculated elastic moduli of each layer. In addition, this work also evaluated the structural influence caused by the presence of damaged pavers, since it became a recurring problem. Regarding the hydraulic evaluation, the surface infiltration rate was monitored over twenty months after the pavement construction. Furthermore, functional and laboratorial analyses were carried out in order to check the structure serviceability level. The structural results indicated clearly that the articulated block side had better performance than the non-articulated block side in terms of elastic moduli, maximum deflections measurements and LTE, confirming the interlocking efficiency generated by the block shape, comparable to that one provided by the jointing sand in ICB. As the recycled aggregate was characterized by a more well graded particle size distribution than the natural aggregate, the RCA base also presented better structural responses. The presence of damaged blocks did not compromise the pavement structural performance, since the degree of severity was low, as verified by the functional evaluation, which showed a pavement in good conditions. Finally, concerning the hydraulic results, the pavement presented a high infiltration capacity. Even though an infiltration loss of about 20% per year has been detected, the infiltration rate remained greater than 10-3 m/s for all tests performed, being considerably higher than those found in pavements built with both interlocking concrete blocks and with porous asphalt, as reported in the literature.
274

Generalizações do teorema de representação de Riesz / Generalizations of the Riesz Representation Theorem

Batista, Cesar Adriano 19 June 2009 (has links)
Dados um espaço de medida (X;A;m) e números reais p,q>1 com 1/p+1/q=1, o Teorema de Representação de Riesz afirma que Lq(X;A;m) é o dual topológico de Lp(X;A;m) e que Loo(X;A; m) é o dual topológico de L1(X;A;m) se o espaço (X;A;m) for sigma-finito. Observamos que a sigma-finitude de (X;A;m) é condição suficiente mas não necessária para que Loo(X;A;m) seja o dual de L1(X;A;m). Os contra-exemplos tipicamente apresentados para essa última identificação são \"triviais\", no sentido de que desaparecem se \"consertarmos\" a medida , transformando-a numa medida perfeita. Neste trabalho apresentamos condições sufcientes mais fracas que sigma-finitude a fim de que Loo(X;A;m) e o dual de L1(X;A;m) possam ser isometricamente identificados. Além disso, introduzimos um invariante cardinal para espaços de medida que chamaremos a dimensão do espaço e mostramos que se o espaço (X;A;m) for de medida perfeita e tiver dimensão menor ou igual à cardinalidade do continuum então uma condição necessária e suficiente para Loo(X;A;m) seja o dual de L1(X;A;m) é que X admita uma decomposição. / Given a measure space (X;A;m) and real numbers p,q>1 with 1/p+1/q=1, the Riesz Representation Theorem states that Lq(X;A;m) is the topological dual space of Lp(X;A;m) and that Loo(X;A; m) is the topological dual space of L1(X;A;m) if (X;A; m) is sigma-finite. We observe that the sigma-finiteness of (X;A;m) is a suficient but not necessary condition for Loo(X;A;m) to be the dual of L1(X;A;m). The counter-examples that are typically presented for Loo(X;A;m) = L1(X;A;m)* are \"trivial\", in the sense that they vanish if we fix the measure , making it into a perfect measure. In this work we present suficient conditions weaker than sigma-finiteness in order that Loo(X;A; m) and L1(X;A;m)* can be isometrically identified. Moreover, we introduce a cardinal invariant for measure spaces which we call the dimension of the space and we show that if the space (X;A;m) has perfect measure and dimension less than or equal to the cardinal of the continuum then a necessary and suficient condition for Loo(X;A;m) = L1(X;A;m)* is that X admits a decomposition.
275

Análise de blocos de concreto armado sobre duas estacas com cálice totalmente embutido mediante presença de viga de travamento / Analysis of two pile caps reinforced concrete with embedded socket by presence of locking beam

Barros, Rodrigo 22 May 2009 (has links)
Esta pesquisa estuda o comportamento de blocos de concreto armado sobre duas estacas com cálice totalmente embutido, utilizado na ligação pilar-fundação de estruturas de concreto pré-moldado. Particularmente, foi avaliado o efeito que a viga de travamento provoca no bloco quando apoiada nas paredes laterais do cálice. Foi desenvolvida análise numérica tridimensional utilizando programa baseado no método dos elementos finitos (MEF), na qual foi considerada a não-linearidade física dos materiais. Para avaliação do programa adotado, realizou-se análise comparativa de resultados experimentais e numéricos obtidos por meio de outro programa. Nos blocos estudados variou-se a espessura e o tipo de conformação das paredes do cálice, o ângulo de inclinação da biela e a intensidade das ações na viga de travamento. Os resultados indicam que a presença da viga de travamento não altera de modo significativo o comportamento do bloco, e que a parede do cálice é capaz de transferir a força proveniente da viga em direção às estacas de modo eficaz. Por meio das tensões nas barras da armadura principal, foi possível obter a força no tirante e o ângulo de inclinação da biela antes da ruína dos modelos. Constatou-se que os ângulos apresentaram maior inclinação do que as utilizadas no dimensionamento, que por sua vez foi feito baseado nos modelos de bielas e tirantes. / The present research studies the behavior of two pile caps reinforced concrete with embedded socked used in connections of pre-cast concrete structures. It was particularly evaluated the effect provoked by the locking beam on the pile-caps when supported by the socket lateral walls. Three-dimensional numerical analyses using software based on finite element method (FEM) were developed considering the nonlinear physical behavior of the material. To evaluate the adopted software, a comparative analysis was made using numerical and experimental results obtained from other software. In the pile caps studied, it was noticed a variation in the wall thickness, socket interface, strut angle inclination and action on beam. The results show that the presence of beam does not change significantly the pile caps behavior and that the socket wall is able to transfer effectively the force from the beam to the pile caps. By the tensions on the bars of longitudinal reinforcement, it was possible to obtain the force on the tie and the strut angle inclination before the collapse of models. It was found that the angles present more inclinations than those used in the design, which was made based on strut and tie model.
276

Análise do comportamento de blocos sobre quatro estacas com cálice embutido / Analysis of the behavior of four-pile caps with embedded socket

Marek Filho, Carlos Antônio 19 August 2010 (has links)
A racionalização e a industrialização da construção civil têm promovido o sistema construtivo baseado em elementos de concretos pré-moldados. O comportamento das ligações entre os elementos pré-moldados constitui uma das principais preocupações dos projetistas, sendo as ligações entre a superestrutura e as fundações determinantes na estabilidade e na distribuição de esforços solicitantes da estrutura. O comportamento de blocos sobre estacas com ligações para pilares pré-moldados possui particularidades em razão do diferente mecanismo de transferência de forças do pilar para o bloco mediante a ligação. Neste trabalho é estudado o comportamento de blocos de fundação apoiados sobre quatro estacas com cálice totalmente embutido para ligação com pilar pré-moldado. O estudo baseou-se em análise numérica não-linear de modelos tridimensionais considerando a fissuração do concreto, a presença de armadura e a interface de ligação. O comportamento de blocos com pilares submetidos à força vertical centrada e excêntrica foi descrito em termos de força última, panorama de fissuração, fluxo de tensões principais e tensões nas armaduras do bloco. Os resultados indicam a ocorrência de transferência de esforços do pilar para a fundação a partir das paredes do cálice de interface lisa, entretanto com intensidade insuficiente para a formação de bielas de compressão, e o risco da ocorrência de punção em blocos onde os pilares são ligados por cálices de paredes lisas. / The rationalization and the industrialization of the civil constructions have stimulated the construction process based on precast elements. One of the main designer\'s worries is about the behavior of the joints between precast elements, and the joints between superstructure and the foundations which are determinant in the construction stability and behavior of elements. In reason of the mechanism of transference of the forces from column to pile-cap by socket connections, the behavior of pile-caps with joints for precast columns has some specificity. The behavior of four-pile caps with embedded socket for precast columns joints is studied in this research. The study is based in nonlinear numerical analysis of three dimensional models considering the cracking in concrete, the reinforcement and the joint interface. The behavior of pile caps under centered and eccentric vertical force is described by ultimate force, cracking patterns, principal stresses flow and reinforcements strains. The results suggests that occurs the transfer of forces from column to the pile cap in the socket walls with smooth interface, however the intensity is not enough to form the struts, and the risk of development of punching shear in pile caps which columns are connected by smooth interface socket walls.
277

Simulação numérica de blocos e prismas de alvenaria em situação de incêndio / Numerical simulation of masonry blocks and prisms under fire situation

Francielle da Silva Rodovalho 23 May 2018 (has links)
A alvenaria estrutural é um sistema construtivo muito antigo no qual as paredes exercem função estrutural além da função de vedação. Este sistema construtivo é muito utilizado no Brasil, entretanto, poucas pesquisas foram realizadas sobre o seu comportamento em situação de incêndio e o país ainda não possui métodos normativos de dimensionamento de alvenaria estrutural em situação de incêndio. Assim, o objetivo deste trabalho foi verificar o desempenho da alvenaria estrutural com blocos de concreto submetida a elevadas temperaturas através da simulação de prismas. No software Abaqus foram simulados o comportamento do bloco e prisma sujeitos à compressão em temperatura ambiente e do prisma em situação de incêndio com diferentes condições de contorno. O comportamento do bloco e prisma sujeitos à compressão e em temperatura ambiente foi validado até a carga última. As elevações de temperatura das faces não expostas ao fogo ficaram bem representadas por meio das simulações térmicas. A perda de resistência dos materiais foi adotada conforme a literatura técnica nas simulações termomecânicas. Através do que foi analisado no trabalho observou-se que os prismas se comportam bem quanto ao isolamento térmico em situação de incêndio, principalmente aquele com revestimento em argamassa nas duas faces. Quanto ao critério de resistência mecânica os resultados numéricos não foram validados com experimentais, entretanto, foi possível representar a deterioração térmica dos materiais. / The structural masonry is a very old building system in which the walls have structural and partition function. The use of this building system is widely spread in Brazil, however, few research programs were carried out on their behavior under fire situation and the country has not yet developed standard normative methods for designing structural masonry subject to fire. Thus the purpose of this research was to verify the performance of concrete blockwork structural masonry submitted to high temperatures through the simulation of prisms. In the Abaqus software the behavior of block and prism subjected to compression at room temperature and of the prism under fire situation with different boundary conditions were simulated. The compression of the block and prism at room temperature was validated until ultimate loads. The temperature rises of the non-exposed faces were well represented through thermal simulations. The material\'s resistance loss was adopted according to the technical literature in the thermomechanical simulations. Based on the analyzed examples it was observed that the prisms behave well regarding the thermal insulation under fire situation, mainly when having mortar coating on both sides. Regarding the mechanical resistance criterion, the numeric results were not validated with experimental ones, however, it was possible to represent the thermal deterioration of the materials.
278

Análise numérica e experimental de blocos de concreto armado sobre duas estacas com cálice externo, parcialmente embutido e embutido utilizado na ligação pilar-fundação / Numerical and experimental analysis of two pile caps reinforced concrete with external, partially embedded and embedded socket used in column-foundation connection

Barros, Rodrigo 08 November 2013 (has links)
Esta pesquisa estuda o comportamento de blocos de concreto armado sobre duas estacas utilizado na ligação pilar-fundação de estruturas de concreto pré-moldado, submetida a ação de força centrada. Nessa situação, a ligação pilar-fundação pode ocorrer por meio do cálice de fundação, que por sua vez pode estar embutido, parcialmente embutido com parte do colarinho saliente, ou externo com o colarinho saliente em relação ao bloco de fundação. Apresenta-se nesta pesquisa o estudo experimental e numérico de blocos de fundação sobre duas estacas com cálice externo, parcialmente embutido e embutido, submetidos à ação centrada utilizando modelos em escala reduzida 1:2. Nos modelos analisados, considerou-se a conformação das paredes do cálice e do pilar com e sem rugosidade. Os resultados são comparados a dois blocos de referência, os quais apresentaram ligação monolítica entre o pilar e o bloco. Foi desenvolvida análise numérica tridimensional utilizando programa baseado no método dos elementos finitos (MEF), na qual foi considerada a não-linearidade física dos materiais. Observa-se que os blocos da série com rugosidade apresentaram maior rigidez e maior força última comparados aos blocos da série sem rugosidade. A armadura adicional utilizada nos modelos sem interface rugosa conferiu aumento na resistência dos modelos na ordem de 15%, o que não ocorreu nos modelos com rugosidade. Particularmente, no caso de blocos com cálice embutido e sem rugosidade, observou-se comportamento de bloco flexível, diferente dos demais modelos. / The present research studies the behavior of two pile caps reinforced concrete used in column-foundation connection of precast concrete structures, submitted to centered load. This situation allows that pile-foundation connection can occur by socket, which can be embedded, partially embedded or external, with socket walls over the pile caps. The research presents an experimental and numerical study of two pile caps reinforced concrete with external, partially embedded and embedded socket, submitted to centered load, using 1:2 scaled models. These models present the socket walls with rough and smooth interface. The results are compared with two reference models, which present a monolithic connection between pile caps and column. Three-dimensional numerical analyses using software based on finite element method (FEM) were developed considering the nonlinear physical behavior of the material. It was observed that pile caps with rough interface present stiffness and ultimate load greater than pile caps with smooth interface. Additional reinforcement using on models with smooth interface add a 15% resistance on models, but this effect did was not observed on the model with rough interface. Particularly, models with smooth interface and embedded socket present a flexible pile caps behavior.
279

Utilização de pós residuais e fibra de sisal em blocos de concreto / Use of residual powders and sisal fiber in concrete blocks

Soto Izquierdo, Indara 27 May 2015 (has links)
A pesquisa tem como enfoque fundamental a aplicação de novos materiais alternativos para uma construção sustentável. Pós residuais, provenientes do resíduo orgânico e do setor mineral, e fibras de sisal constituem bons exemplos de materiais não convencionais. Dessa forma, o objetivo principal foi avaliar a incorporação dos pós residuais e da fibra de sisal no concreto para a fabricação de blocos de concreto e elementos de alvenaria. Foram estudados três relações cimento: agregado, de 1:15, 1:10 e 1:6 (traços pobre, médio e rico), com a finalidade de produzir blocos estruturais com classe de resistência, de 4, 8 e 12 MPa, respectivamente. Para cada traço foi realizada a substituição da areia natural por pó de pedra com teores de 20%, 40%, 60% e 80%, em massa, e do cimento por pó de resíduo orgânico com teores de 5%, 10%, 15% e 20%, em massa. Foi feito o estudo da durabilidade da fibra de sisal em meio alcalino, com comprimento de 20 mm e fração volumétrica de 1% com relação ao concreto. Foram estudadas as propriedades físicas e mecânicas do concreto no estado fresco e endurecido. Os resultados mostraram que os pós residuais podem ser utilizados como fíler no concreto substituindo parte da matéria prima, uma vez que causaram o correto empacotamento nos agregados e na pasta de cimento. O estudo estatístico utilizando a técnica do Bootstrap mostrou que para o pó de pedra, a porcentagem ideal para a substituição da areia pelo pó no concreto foi de 60% para os traços 1:15 e 1:10 e de 40% para o traço 1:6. Já no pó de resíduo orgânico, concretos com baixo consumo de cimento, o resíduo não teve um correto enchimento na matriz cimentícia; com médio consumo, o concreto com 5% de pó apresentou propriedades mecânicas e físicas superiores ao concreto de referência; e em misturas ricas em cimento, porcentagens até 10% provocaram um correto desempenho mecânico quando comparados ao concreto de referência. O sisal apresentou alta durabilidade em matrizes cimentícias modificadas com materiais pozolânicos devido à diminuição do hidróxido de cálcio (CH). Foi possível concluir que os blocos de concreto modificados com os materiais alternativos apresentaram qualidade compatível com as exigências da construção civil nacional e podem ser utilizados também como unidades de vedação. / This research deals with the use of new alternative materials for sustainable construction. The use of residual powder materials, from organic residue and from mineral sector, and sisal fibers are good examples of unconventional materials that can be used. The main objective is to evaluate the use of residual powders and sisal fibers in the production of structural masonry blocks. Three types of mixtures for cement consumption were studied: aggregate/cement (A/C) ratios of 15, 10, and 6, in order to produce blocks structural strength classes of 4, 8 and 12 MPa, respectively. For each trace the cement were replaced by powder organic waste at levels of 5%, 10%, 15% and 20%, and natural sand replaced by stone powder at levels of 20%, 40%, 60% and 80%. A study was carried out in order to evaluate the durability of sisal fiber in the alkaline medium, with length of 20 mm and 1% volume fraction on the concrete. The physical and mechanical properties of fresh and hardened concrete were studied. The results showed that residual powder can be used as filler in concrete by replacing part of the raw material, since they caused the correct packaging in the aggregates and in the cement paste. The statistical analysis using the Bootstrap technique showed that for the stone powder the optimal percentage for replacing the sand was 60% for 15:1 and 10:1 traces and 40% for 6:1 trace. As for the organic residual powder, the results showed that the reference concrete had higher compressive strength than the concrete with low cement content (A/C ratio of 15:1). However, samples made with 5% powder and an A/C ratio of 10:1 showed greater physical and mechanical properties strength than the reference concrete. Mixtures rich in cement (A/C ratio of 6:1) and the powder replacements of up to 10% resulted in the best mechanical behavior. The sisal showed high durability in modified cementitious matrices with pozzolanic materials due to decreased calcium hydroxide (CH). It was concluded that the blocks modified with alternative materials showed quality compatible with the requirements of national construction.
280

Resistência e deformabilidade de blocos vazados de concreto e suas correlações com as propriedades mecânicas do material constituinte / Strength and deformability of concrete hollow blocks and their correlation to mechanical properties of constituent material

Barbosa, Claudius de Sousa 23 April 2004 (has links)
O trabalho tem como objetivo correlacionar as propriedades mecânicas de blocos vazados com as do concreto que o constitui. Moldam-se blocos vazados e corpos-de-prova de dimensões distintas com concreto plástico em três níveis de resistência (10, 20 e 30 MPa) e caracterizam-se as propriedades mecânicas por meio de ensaios à compressão axial e à tração. Ensaiam-se à compressão axial prismas constituídos por dois e três blocos de concreto sem junta de argamassa, unidos por adesivo à base de epóxi. Observa-se que a relação entre as resistências do bloco e prisma e a resistência do concreto diminui com o aumento da altura desses elementos. Obtém-se o módulo de elasticidade longitudinal do concreto, a partir de ensaios com corpos-de-prova. Analisam-se as deformações em diversos pontos do bloco quando submetidos à compressão axial. Devido à distribuição não uniforme de tensões nos blocos e prismas, obtêm-se diferentes valores de deformação ao longo das paredes dos elementos. Os blocos, por possuírem menor altura que os prismas, apresentam maior diferença entre os valores de deformação. Por meio de simulações numéricas, no regime linear, observa-se que a placa de ensaio não se desloca uniformemente, acarretando os distintos valores de deformação ao longo do bloco. Uma forma peculiar de cálculo, baseada nessas deformações, permite a previsão da capacidade resistente do bloco e conduz a valores próximos da força máxima de ensaio. Apresenta-se ainda, uma tentativa de prever a deformabilidade do bloco vazado de concreto a partir das propriedades mecânicas do concreto. / This research aims to correlate the mechanical properties of hollow blocks to those of the concrete used to build them. Concrete hollow blocks and test samples of different shapes and sizes (cylinder 50 x 100, 100 x 200 and 150 x 300 mm) were molded with plastic consistency concrete in three different levels of strength (nominally 10, 20 and 30 MPa). Their mechanical properties and structural behavior in axial compression and tension tests were determined. Also two and three block prisms were built without mortar joints, pilled up with epoxy glue. It could be observed that the relationship between block strength or prism strength and concrete strength (measured in test samples) decreases with increasing of the element\'s height. Stress and strain analyses were made based on the concrete\'s modulus of elasticity obtained in sample tests and on the measured strain in the blocks\' faces and webs. By linear numerical simulations it was observed that loading plate does not show uniform displacement values, causing significant differences between theoretical and experimental behavior. A peculiar stress-strain analysis permitted to calculate the block load capacity based in its deformations. Also a tentative method to preview the block deformability from the concrete mechanical properties is described and tested.

Page generated in 0.0678 seconds