• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 301
  • 56
  • 10
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 425
  • 425
  • 230
  • 136
  • 95
  • 94
  • 92
  • 84
  • 78
  • 75
  • 71
  • 71
  • 71
  • 62
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Avaliação da resistência ao cisalhamento de reparos de resina: interface tratada com laser de Er Yag, ponta diamantada e jato abrasivo com óxido de alumínio

Rossato, Desirée Mory [UNESP] 26 July 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-07-26Bitstream added on 2014-06-13T19:10:19Z : No. of bitstreams: 1 rossato_dm_me_arafo.pdf: 1938222 bytes, checksum: fb0dee4a630e9b7c50ea8d084d2ad7cb (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi realizar avaliação da resistên - cia de união ao cisalhamento de reparos de resina compostas em restaurações com resina composta envelhecidas, em função de diferentes tratamentos superficiais. Foram confeccionados 60 corpos-de-prova de resina composta Z250 (3M) e levados a termociclagem para simular o envelhecimento da restauração, foram realizados 500 ciclos de 15 segundos cada, variando entre 5°e 55°C. Separados aleatoriamente em seis grupos que sofreram os seguintes tratamentos superficiais: nenhum tratamento (G1 - controle), desgaste com ponta diamantada (G2), jato de óxido de alumínio com partículas de 27,5æm (G3) por 10 segundos, laser de Er:YAG - 200mJ (G4), laser de Er:YAG - 300mJ (G4) e laser de Er:YAG - 400mJ (G6), os três últimos com freqüência de 10Hz por 10 segundo. Foi realizada microscopia eletrônica de varredura para observarmos o aspecto do material após os tratamentos terem sido executados. O reparo da restauração foi realizado utilizando-se a mesma resina. O teste de cisalhamento foi feito na Máquina de Ensaios Mecânicos MTS - 810. Analisando os resultados por ANOVA e pelo teste de Tukey não foram encontradas diferenças significativas (p-valor=0.5120). A análise dos valores medianos, mostrou que o tratamento superficial com jato de óxido de alumínio apresentou uma maior resistência da interface do reparo ao cisalhamento (8.91Mpa) enquanto que o laser de Er:YAG com 400mJ de potência, apresentou a menor (6.76Mpa). A análise dos tipos de fratura mostrou que 90% dos corpos-de-prova do grupo 3 (óxido de alumínio) sofreram fraturas coesivas. / The aim of this work was to perform the evaluation of the shear bond strength of the composite resin repairs in old composite restorations, modifying the superficial treatment of the samples. Sixty samples of the composite resin Z250 (3M) were prepared and thermocycled for 500 cycles at 5° and 55°C with a dwelling time of 15 seconds. Speciments were randomly divided into six groups and subjected to different surface treatments as follows: No surface treatment (G1 - control), grinding with a diamond bur (G2), sandblasting with a microetcher for 10 seconds with 27,5æm Al2O3 particles (G3), treated with Er:YAG laser with an energy intensity of 200mJ (G4), 300mJ (G5), 400mJ (G6), frequency of 10Hz for 10 seconds. The speciments after surface treatment were observed using the scanning electron microscope. The repair of the old resin was done with the same material. The shear bond strength test was performed in a Mechanic Testing MTS - 810. Statistical treatment by ANOVA and Tukey's test showed no significant differences between the groups tested (p=0.5120). The highest shear bond strength values were achieved by sandblasting the surface with a microetcher with Al2O3 (8,91Mpa), whereas the lowest values were obtained with Er:YAG laser with energy intensity of 400mJ (6.76Mpa). Observing the rupture surface, G3 presented 90% of cohesive failures.
122

Avaliação in vitro da resistência de união em dentina irradiada com o laser de Er:Yag, mediante a aplicação de diferentes sistemas adesivos

Guzmán Sierpinski, Liz Marie [UNESP] 04 March 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-03-04Bitstream added on 2014-06-13T19:10:21Z : No. of bitstreams: 1 guzmansierpinski_lm_me_arafo.pdf: 1201858 bytes, checksum: 539d83858e78947f655c7f5c650b9e93 (MD5) / O objetivo deste trabalho foi avaliar a influência que o laser de Er:YAG exerce sobre a resistência de união do material restaurador ao substrato dentinário, associando-se a diferentes sistemas adesivos. Para isto foram avaliados 30 molares humanos livres de cárie divididos em três grupos experimentais, utilizando o laser de Er:YAG com uma energia de 260 mJ/10Hz e três grupos controles, em que foram aplicados os seguintes tratamentos: G1) laser, ácido fosfórico a 37%, Excite/Vivadent; G2) controle, ácido fosfórico a 37%, Excite/Vivadent; G3) laser, sistema adesivo Prompt L-pop/Espe; G4) controle, Prompt L-pop;/Espe; G5) laser, ácido fosfórico a 37%, Single Bond/3M; G6) controle, ácido fosfórico a 37%, Single Bond/3M. Todas as amostras foram restauradas com a resina composta Tetric Ceram/Vivadent, termocicladas em 550 ciclos e cortadas, obtendo-se espécimes de mais ou menos 1mm,2 para serem levados a uma Máquina de Testes Universal onde foi realizado o ensaio de microtração. Os tipos de fraturas ocorridos foram analisados mediante microscopia óptica digital e as fraturas mais representativas foram levadas à microscopia eletrônica de varredura. Os resultados mostraram que o sistema laser de Er:YAG apresentou as menores médias de tensão de ruptura, independente do sistema adesivo utilizado. O sistema adesivo Prompt l-pop mostrou resistência adesiva estatisticamente menor em relação aos outros sistemas adesivos estudados. Não houve diferença estatística entre os sistemas adesivos Single Bond e Excite. A maior parte das fraturas encontradas para todos os grupos foram do tipo adesiva. / The aim of this study is to evaluate the influence of the laser Er:YAG to the junction resístance between the tooth surface and the restorative material , using different adhesives . For this study were used 30 human healthy molars, divided in three experimental groups and three control groups. The experimental groups were exposed to a laser of Er:YAG with 260 mJ/10Hz of energy. The six groups were: G1) laser, phosforic acid at 37%, Excite/ Vivadent. G2) control, phosforic acid at 37 % , Excite/ Vivadent. G3) laser, adhesive system Prompt L-pop/ Espe. G4) control, adhesive system Prompt L-pop/ Espe. G5) laser, phosforic acid 37% , Single Bond/ 3M. G6) control, Single Bond/ 3M. All the teeth were restored with the composite Tetric Ceram/ Vivadent. Then thermocycled 550 times and cut in specimens of 1mm2. In these specimens was made a test of micro tensile bond strength in a Universal Test Machine. The fractures were analyzed in a digital optical microscope, and more representative fractures were then analyzed in a electronic microscope. The results revealed that the groups treated with laser Er:YAG presented less tensile bond strengh, independently to the adhesive system used. The adhesive Promp 1-pop presented less tensile bond strengh compared to the other adhesives evaluated. There no was difference between the groups of Single Bond and Excite. The fractures more commun were the adhesive type.
123

Efeitos de lasers de alta potência na superfície de cerâmicas vítreas de dissilicato de lítio e sua resistência de união à dentina humana / Effects of high power laser irradiation on lithium di-silicate glass ceramic surface and bond strength to human dentin

Feitosa, Fernanda Alves [UNESP] 02 June 2016 (has links)
Submitted by Fernanda Alves Feitosa null (fernanda.feitosa@fosjc.unesp.br) on 2016-06-07T14:46:57Z No. of bitstreams: 1 Tese ok - versão final com ficha catalografica certa.pdf: 3711607 bytes, checksum: d94558d40ddaabd3c84ddd7cdec2d8bb (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-06-08T13:34:17Z (GMT) No. of bitstreams: 1 feitosa_fa_dr_sjc.pdf: 3711607 bytes, checksum: d94558d40ddaabd3c84ddd7cdec2d8bb (MD5) / Made available in DSpace on 2016-06-08T13:34:17Z (GMT). No. of bitstreams: 1 feitosa_fa_dr_sjc.pdf: 3711607 bytes, checksum: d94558d40ddaabd3c84ddd7cdec2d8bb (MD5) Previous issue date: 2016-06-02 / O objetivo desse estudo foi avaliar a eficiência da irradiação com lasers de alta potência e a influência da aplicação do silano previa ou posteriormente à irradiação com os lasers na resistência de união entre cerâmica vítrea de dissilicato de lítio, cimento resinoso e dentina humana. Foram confeccionados 50 espécimes tronco-cônicos de cerâmica (n=10), divididos aleatoriamente em 5 grupos: 1- Controle- Condicionamento com ácido hidrofluorídrico 10% por 1 min e aplicação do silano; 2- Er:YAG – irradiação com laser Er:YAG (200 mJ e 10 Hz), seguido do condicionamento com ácido hidrofluorídrico 10% por 1 min e aplicação do silano; 3- Silano + Er:YAG – Condicionamento com ácido hidrofluorídrico 10% por 1 min, aplicação do silano e irradiação com laser Er:YAG nos mesmo parâmetros do grupo anterior; 4- Nd:YAG – irradiação com laser Nd:YAG (120 mJ e 10 Hz), seguido de condicionamento com ácido hidrofluorídrico 10% por 1 min e aplicação do silano, 5- Silano + Nd:YAG - Condicionamento com ácido hidrofluorídrico 10% por 1 min, aplicação do silano e irradiação com laser Nd:YAG nos mesmo parâmetros do grupo anterior. Após os tratamentos os espécimes cerâmicos foram cimentados com cimento resinoso de presa dual à superfície de dentina de 50 molares humanos incluídos em resina acrílica ativada quimicamente. Após armazenamento por 24 h foi realizado o ensaio de tração em máquina de ensaios universais com célula de carga de 10 KgF e velocidade constante de 1mm/min. Os dados obtidos foram submetidos à ANOVA 2-fatores e teste de Dunnet (α=5%). A análise dos padrões de fratura foram analisadas em estereomicroscopio. Adicionalmente foram confeccionados 15 espécimes em cerâmica no formato cilíndrico, submetidos aos mesmo tratamentos dos grupos anteriores (n=3) e utilizados para análise do ângulo de contato e análise em microscópio eletrônico de varredura. O teste de Dunnet mostrou diferenças significativas entre o grupo controle (9,42 ± 2,27 MPa) e os grupos Er (19,25 ± 3,7 MPa) e Sil+Er (14,11 ± 4,11 MPa). A análise de variância (p<5%) para os fatores Tipo de Laser (p<0,0001) e Técnica de Silanização (p=0,0002) mostraram diferenças significativas para os dois fatores, porém não para sua interação. Assim, a irradiação com Er:YAG (16,68 MPa) mostrou-se mais eficiente que a irradiação com Nd:YAG (8,19 MPa). A técnica de silanização posterior à irradiação com laser (14,46 MPa) também se mostrou superior à silanização previa (10,41 MPa). Quanto à análise de fraturas, o grupo Controle teve prevalência de falhas adesivas em dentina e em cerâmica; os grupos Nd, Sil + Nd e Sil + Er tiveram prevalência de falhas adesivas em cerâmica, e o grupo Er apresentou predominância de falhas coesivas no cimento. A análise do ângulo de contato foi submetida aos testes ANOVA 1-fator e Tukey, apresentando diferenças significativas entre os grupos (p<0,0001). Os grupos com silanização prévia (Sil + Er = 45,60b graus; Sil + Nd = 52,10b graus) apresentaram ângulos de contato superiores aos demais, e semelhantes entre si. As imagens de Microscopia Eletrônica de Varredura mostram a presença da camada de silano sobre a superfície cerâmica no grupo Sil + Nd, e uma aparente fundição à superfície cerâmica no grupo Sil + Er. Para os Grupos Er e Nd foi possível verificar modificações no padrão normal da estrutura da cerâmica, entremeadas por áreas semelhantes ao padrão convencional do grupo Controle após condicionamento com ácido hidrofluorídrico. Conclui-se que o tratamento com laser de Érbio associado ao condicionamento com ácido hidrofluorídrico a 10% por 1 min apresenta os melhores resultados de resistência de união e ângulo de contato. O tratamento com silano previamente à irradiação melhorou a resistência de união em relação ao grupo Controle apenas quando associado ao laser de Érbio. / The aim of this study was to evaluate the efficiency of irradiation with high-power lasers and the influence of silane application before or after irradiation with lasers on the bond strength between lithium disilicate glass-ceramic, resin cement and human dentin. Fifty truncated-cones ceramic specimens (n=10) were randomly divided into 5 groups: Control- etching with hydrofluoric acid 10% for 1 min and application of silane; 2- Er - Er:YAG laser irradiation (200 mJ and 10 Hz), followed by etching with hydrofluoric acid 10% for 1 min and application of silane; 3- Sil + Er - etching with hydrofluoric acid 10% for 1 min, silane application and irradiation with Er: YAG laser in the same parameters as the previous group; 4- Nd:YAG laser - irradiation with Nd: YAG laser (120 mJ and 10 Hz), followed by etching with hydrofluoric acid 10% for 1 min and application of the silane, 5- Sil + Nd- Etching with hydrofluoric acid 10% for 1 min, silane application and irradiation with Nd: YAG laser on the same parameters as the previous group. After treatment, the ceramic specimens were cemented with dual cure resin cement to the dentin of 50 human molars included in acrylic resin. After storage for 24 h it was submitted to tensile test in a universal testing machine with 10 kgf load cell and constant speed of 1 mm/min. Data were submitted to ANOVA 2-way and Dunnet test (α = 5%). The analysis of fracture patterns were analyzed in stereomicroscope. In addition were made 15 ceramic specimens in cylindrical shape, subjected to the same treatment of the above groups (n = 3) and used for analysis of the contact angle analysis and scanning electron microscope. The Dunnet test showed significant differences between Control group (9.42 ± 2.27 MPa) and Er group (19.25 ± 3.7 MPa) and Sil + Er (14.11 ± 4.11 MPa). ANOVA 2-way (p <5%) for Laser Type (p <0.0001) and Technical of Silanization (p = 0.0002) showed significant differences for both factors, but not for their interaction. Thus, the irradiation with Er:YAG laser (16,68 MPa) was more effective than irradiation with Nd:YAG laser (8,19 MPa). The technique of silanization after laser irradiation was more effective (14,46 MPa) than the previous silanization (10,41 MPa). The analysis of fractures showed a prevalence of adhesive failures on dentin and ceramic for the Control group; Nd, Sil + Nd e Sil + Er had a prevalence of adhesive failures in ceramics, and Er group presented predominance of cohesive failures in cement. The analysis of contact angle was submitted to ANOVA 1-way and Tukey test, with significant differences between the groups (p <0.0001). Groups with silanization previous to laser irradiation (Sil + Er = 45,60b degrees; Sil + Nd = 52,10b degrees) had contact angles greater than the other groups. The Scanning Electron Microscopy images showed the presence of a silane layer on the ceramic surface in Sil + Nd group, and an apparent casting of the ceramic surface in Sil + Er group. For Er and Nd Groups was possible to see changes in the normal pattern of ceramic structure, interspersed with areas similar to conventional standard control group after etching with hydrofluoric acid. It is concluded that treatment with Er:YAG laser associated with etching with hydrofluoric acid at 10% for 1 min gives the highest bond strength results and the lower contact angle, resulting in a recommended treatment. Treatment with silane previously to laser irradiation improved bond strength only when associated with the Er:YAG laser, which probably occurred by the efficiency of Er: YAG laser irradiation, and not due to the silanization technique.
124

Efeito de desinfecções sucessivas com energia de microondas na resistência de união entre dentes artificiais e resinas para bases de próteses

Chuqui, Roberta [UNESP] 28 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-28Bitstream added on 2014-06-13T18:38:57Z : No. of bitstreams: 1 chuqui_r_me_arafo.pdf: 5214724 bytes, checksum: 7fcde9af460bda49c5c01007a97620cc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito de desinfecções sucessivas por meio da utilização de microondas sobre a resistência de união entre dentes artificiais (incisivos centrais superiores: Biotone - DB, modelo 264 e Vivodent - DV, modelo A15) e resinas para bases (QC20 - QC, Acron MC - AC e Lucitone 550 - L). Os dentes artificiais foram posicionados em anéis de PVC (20 mm de diâmetro e 20 mm de altura) preenchidos com cera. Cada anel foi incluído em silicone por condensação para facilitar posteriormente a remoção das amostras polimerizadas. Esses moldes de silicone foram então incluídos em mufla dental com gesso. A cera foi eliminada com água em ebulição, sendo o molde preenchido com resina acrílica, manipulada e polimerizada de acordo com as instruções do fabricante. Quarenta corpos-de-prova foram obtidos para as três resinas de base com as duas marcas de dentes avaliados. Todas as amostras foram divididas aleatoriamente em quatro grupos. G1 (controle) - amostras imersas em água destilada a 37ºC por 48 horas; G2 - imersas por 48 horas e submetidas a dois ciclos de desinfecção por 6 minutos a 650 W; G3 - imersas por 48 horas em água destilada e submetidas a sete ciclos de desinfecção (um por dia) por 6 minutos a 650 W, estando as amostras imersas em água a 37ºC entre as desinfecções; G4 - imersas em água destilada por 8 dias (controle). O teste de cisalhamento foi realizado em máquina de ensaios MTS - 810 com a força aplicada na superfície palatina dos dentes em ângulo de 45º e velocidade de 0,5 mm/min. As superfícies de fratura foram observadas em lupa esteroscópica com um aumento de 10 vezes para determinar a natureza da falha (adesiva, coesiva ou mista). Adicionalmente, foi realizada microscopia eletrônica de varredura. Os dados (MPa) foram analisados utilizando ANOVA, teste de Tukey e teste t de Student (P=0,05)... / This study evaluated the effect of microwave disinfection on the bond strength of denture teeth (maxillary central incisors: Biotone - DB, model 264 and Vivodent - DV, model A15) to acrylic resins (QC20 - QC, Acron MC - AC and Lucitone 550 - L). Denture teeth were positioned within polyvinylchloride tubes (20 mm diameter and 20 mm length) filled with melted wax. The tubes were invested in silicone rubber to facilitate removal of the processed specimens from the flask. These silicone moulds were then invested in the usual denture flasks in dental stone. The wax was boiled out, the mould was packed with denture resin and polymerized according to the manufacturer's instructions. Forty specimens were formed from each of the three denture base resin with the two brands of denture teeth. All specimens were randomly divided into four groups to provide a sample size of 10. G1 (control group) - immersed in distilled water at 37ºC for 48 hours; G2 - immersed in distilled water at 37ºC for 48 hours and microwaved twice at 650W for 6 minutes; G3 - immersed in distilled water at 37ºC for 48 hours and microwaved (650 W for 6 minutes) daily for 7 days, being stored in water at 37ºC between exposures; G4 (control group) - immersed in distilled water at 37ºC for 8 days. Shear load was applied with a load testing machine at 45 degrees from the long axis of each denture tooth on the palatal surface at a crosshead speed of 0.5mm/min until fracture. Fracture surfaces were evaluated with an optical stereomicroscope under x 10 magnifications to determine the nature of the failure (adhesive, cohesive or combination). In addition, a representative sample of each experimental group was evaluated with a scanning Electron Microscopy (SEM). The data (MPa) were analyzed statistically using 3-way ANOVA, Tukey's test and Student's t test (P=0.05)...(Complete abstract, click electronic address below)
125

Avaliação "in vitro" da resistência de união em dentina irradiada com o laser de Er:Yag, mediante a aplicação de diferentes sistemas adesivos /

Guzmán Sierpinski, Liz Marie. January 2002 (has links)
Resumo: O objetivo deste trabalho foi avaliar a influência que o laser de Er:YAG exerce sobre a resistência de união do material restaurador ao substrato dentinário, associando-se a diferentes sistemas adesivos. Para isto foram avaliados 30 molares humanos livres de cárie divididos em três grupos experimentais, utilizando o laser de Er:YAG com uma energia de 260 mJ/10Hz e três grupos controles, em que foram aplicados os seguintes tratamentos: G1) laser, ácido fosfórico a 37%, Excite/Vivadent; G2) controle, ácido fosfórico a 37%, Excite/Vivadent; G3) laser, sistema adesivo Prompt L-pop/Espe; G4) controle, Prompt L-pop;/Espe; G5) laser, ácido fosfórico a 37%, Single Bond/3M; G6) controle, ácido fosfórico a 37%, Single Bond/3M. Todas as amostras foram restauradas com a resina composta Tetric Ceram/Vivadent, termocicladas em 550 ciclos e cortadas, obtendo-se espécimes de mais ou menos 1mm,2 para serem levados a uma Máquina de Testes Universal onde foi realizado o ensaio de microtração. Os tipos de fraturas ocorridos foram analisados mediante microscopia óptica digital e as fraturas mais representativas foram levadas à microscopia eletrônica de varredura. Os resultados mostraram que o sistema laser de Er:YAG apresentou as menores médias de tensão de ruptura, independente do sistema adesivo utilizado. O sistema adesivo Prompt l-pop mostrou resistência adesiva estatisticamente menor em relação aos outros sistemas adesivos estudados. Não houve diferença estatística entre os sistemas adesivos Single Bond e Excite. A maior parte das fraturas encontradas para todos os grupos foram do tipo adesiva. / Abstract: The aim of this study is to evaluate the influence of the laser Er:YAG to the junction resístance between the tooth surface and the restorative material , using different adhesives . For this study were used 30 human healthy molars, divided in three experimental groups and three control groups. The experimental groups were exposed to a laser of Er:YAG with 260 mJ/10Hz of energy. The six groups were: G1) laser, phosforic acid at 37%, Excite/ Vivadent. G2) control, phosforic acid at 37 % , Excite/ Vivadent. G3) laser, adhesive system Prompt L-pop/ Espe. G4) control, adhesive system Prompt L-pop/ Espe. G5) laser, phosforic acid 37% , Single Bond/ 3M. G6) control, Single Bond/ 3M. All the teeth were restored with the composite Tetric Ceram/ Vivadent. Then thermocycled 550 times and cut in specimens of 1mm2. In these specimens was made a test of micro tensile bond strength in a Universal Test Machine. The fractures were analyzed in a digital optical microscope, and more representative fractures were then analyzed in a electronic microscope. The results revealed that the groups treated with laser Er:YAG presented less tensile bond strengh, independently to the adhesive system used. The adhesive Promp 1-pop presented less tensile bond strengh compared to the other adhesives evaluated. There no was difference between the groups of Single Bond and Excite. The fractures more commun were the adhesive type. / Orientador: Sizenando de Toledo Porto Neto / Coorientador: Vanderlei Salvador Bagnato / Banca: Osmir Batista de Oliveira Júnior / Banca: Alberto Magno Gonçalves / Mestre
126

Influência da presença de um filme fino de platina na resistência de união titânio-cerâmica /

Rodrigues, Flávia Pires. January 2005 (has links)
Resumo: Problemas com a resistência de união metal-cerâmica têm sido encontrados quando o titânio é utilizado em Odontologia. A proposta deste estudo foi aumentar a resistência na interface titânio-cerâmica pela aplicação de um filme fino de platina na superfície do titânio, por meio da utilização da técnica de deposição por pulverização catódica. Dez padrões (1.0 x 4.0 x 30 mm) foram obtidos por meio de cortes de placas de resina acrílica e incluídos em um revestimento à base de zircônia. As fundições de titânio para preenchimento dos moldes foram realizadas em uma máquina de fundição centrífuga. As amostras foram lixadas até as dimensões finais (0.50 x 3.0 x 30 mm) para a remoção da camada -case e jateadas com pó de alumina (grupo controle) e de dióxido de titânio (grupo experimental). Uma cerâmica de ultrabaixa temperatura de fusão foi aplicada no centro da superfície (8.0 x 1.0 x 3 mm). A resistência de união foi determinada pelo teste de flexão de três pontos em uma máquina universal de ensaios com uma velocidade de 0,5mm/min. As amostras foram analisadas por meio de microscopia óptica e microscopia eletrônica de varredura antes e após os ensaios mecânicos. Os resultados revelaram valores maiores de união entre o titânio e a cerâmica quando o filme de platina foi aplicado (25,70 l 4,54 MPa), mas não houve diferença estatística significante em relação ao grupo controle (24,32 l 3,11 MPa), o que indica que o primeiro grupo também possui uma resistência de união suficiente para uso clínico. / Abstract: Problems with metal-ceramic bond strength have been encountered when titanium is used in prosthetic dentistry. The purpose of this study was increase the bond strength of titanium-ceramic interface applying a platinum film on the titanium surface using DC-sputtering deposition technique. Ten 1.0 x 4.0 x 30 mm patterns were cut from sheet of acrylic resin and invested in a zirconia-based investment material. Titanium castings were made using a centrifugal casting machine. Specimens were grinded to final dimensions (0.50 x 3.0 x 30 mm) to remove the -case layer and blasted with alumina (control group) and titanium dioxide (experimental group) powders. An ultra low-fusing dental ceramic was applied to the center of the surface (8.0 x 1.0 x 3 mm). The bond strength was determined by three-point bending test. at a universal testing machine with a loading rate of 0,5mm/min.The samples were analyzed using Optical Microscopy and Scanning Electron Microscopy before and after the mechanical testing.The results showed greater values of adherence between titanium and ceramic when the platinum film was applied (25,70 l 4,54 MPa), but there were no statistic differences to those of the controls (24,32 l 3,11 MPa) that indicates that the first one has also sufficient bond strength for clinical use. / Orientador: Aelcio Zangrandi / Coorientador: Ana Paula Rosifini Alves / Banca: Sigmar de Mello Rode / Banca: Cecília Amélia de carvalho Zavaglia / Mestre
127

A influência do corte com diferentes discos e velocidades na integridade dos espécimes e na resistência adesiva de uma cerâmica a um cimento resinoso dual em ensaio de microtração / The influence of different cutting speeds and brand of diamond saws on integrity of microtensile specimes and Bond strenght values

Martha Chiabai Cupertino de Castro 19 November 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Esta pesquisa estudou a influência de diferentes velocidades de corte e marcas de discos diamantados nos valores de resistência adesiva, durante a preparação dos espécimes a serem submetidos à microtração, e na integridade das amostras por meio do microscópio eletrônico de varredura (MEV). Vinte blocos da cerâmica à base de dissilicato de lítio (IPS e.max Press) foram unidos com cimento resinoso (Rely X ARC) a blocos de compósito (Z100), construídos incrementalmente. Foram seguidas as recomendações dos fabricantes no tratamento da superfície da cerâmica e aplicação do cimento resinoso. Após 24 horas em água destilada a 37C, os espécimes foram divididos em dois grupos de discos: marcas Buehler e Extec e subdivididos nas velocidades de 200rpm e 400rpm (B2; E2; B4 e E4, respectivamente). Cada espécime foi cortado em dois eixos perpendiculares para obtenção de palitos com área adesiva de 1,0mm. Para cada condição experimental, os palitos foram separados, aleatoriamente, 15 palitos para análise ao MEV e 30 palitos para serem submetidos à força de tração. As médias de resistência adesiva em MPa foram E4=20,312 ; B4= 24,2 11,3 ; B2= 25,2 9,0 e E2= 28,6 10,4. Na análise estatística, observou-se que os valores de resistência adesiva na velocidade de 200rpm foram significativamente maiores comparados a velocidade de 400rpm, independente do disco empregado. Ao MEV, observou-se melhor integridade dos palitos na velocidade de 200rpm com presença de trincas menos extensas nas bordas externas. Constatou-se também que o disco Extec na velocidade de 400rpm apresentou movimentos excêntricos ao corte e obteve-se maior número de perdas prematuras, uma diminuição significante na média da área total de união (p<0,05), além de diferença significativa nos valores de resistência comparada a velocidade de 200rpm. Concluiu-se que a utilização de diferentes velocidades e sua interação com o disco empregado interfere na integridade dos espécimes e nos valores de resistência adesiva, sendo mais acentuada ao se utilizar o disco da marca Extec. / The aim of this research was to verify the influence of different cutting speeds and brand of diamond saws during microtensile specimen preparation on the bonding strength values and on the samples microscopy integrity (SEM). Twenty lithium disilicate glass-ceramic blocks (IPS e.max Press) were bonded with dual-cure resin cement (Rely X ARCTM) to composite (Z100TM) blocks, built incrementally. The manufacturers recommendations were followed for ceramic treatment surface and placement on the resin cement, as well. After storage for 24 hours in distillated water at 37C, the specimens were divided in two groups of diamond saws, Buehler and Extec brands, which were further subdivided using 200rpm and 400rpm speeds (B2; E2; B4 and E4 respectively), and they were sectioned into two perpendicular axes obtaining sticks shaped specimens with cross-sectional area of 1.0mm. For each experimental situation the sticks were randomly separated; 15 for the analysis to the SEM and 30 to be submitted to tensile strength. Mean bond strength values (MPa) were: E4 = 20.3 12; B4 = 24.2 11.3; B2 = 25.2 9.0; and E2 = 28.6 10.4. The statistical analysis of data showed that the values of bond strength at 200 rpm speed were significantly higher as compared to 400 rpm speed, regardless of saw employed. In SEM, it was noted better integrity of sticks at 200 rpm speed with presence of less extensive cracks in external edges. It was also found that the Extec saw at 400 rpm showed eccentric movement to cutting and achieved higher number of premature losses, a significant decreased mean total area of bond (p<0.05), in addition to significant difference in strength values compared with 200 rpm speed. It was concluded that using different speeds and their interaction with the used saw interfere with the integrity of specimens and the bond strength values, being more pronounced when using the Extec saw.
128

Resistência de união em dentes decíduos erodidos / Microshear bond strength of self-etch and etch-and-rinse adhesives to eroded primary teeth

Santos, Nicole Marchioro dos January 2016 (has links)
O objetivo deste estudo foi avaliar a resistência de união (RU) do esmalte e da dentina decídua após desafio erosivo utilizando sistemas adesivos convencionais e autocondicionantes. Noventa e seis molares decíduos foram seccionados mesio-distalmente para obtenção de blocos de esmalte, foram embebidos em resina epóxi e polidos com lixas de carbeto de silício (600, 1200, 2400 e 4000). As amostras foram randomizadas e divididas entre os 4 sistemas adesivos utilizados: SB (Adper Single Bond 2), SBU (Single Bond Universal), OBFL (Optibond FL) e BF (Bond Force). Metade das amostras (grupo teste, n=48) foram submetidas a desafio erosivo/abrasivo (50 mL de Coca-Cola®, pH 2,6, 1 min, 4x ao dia, 5 dias, seguido de escovação por 1 min com dentifrício fluoretado, NaF 1450 ppm e saliva artificial). A outra metade dos blocos (grupo controle) foi mantida imersa em saliva artificial. Em seguida foram realizadas restaurações de resina flow (Tetric Flow) utilizando matrizes de polivinil siloxano com diâmetro de 0,9mm e 1mm de altura. As amostras foram colocadas na máquina de ensaio universal e foi aplicada força de cisalhamento com velocidade de 1,0mm/min até que a fratura ocorresse. Os mesmos blocos tiveram suas superfícies de dentina expostas, em seguida, as mesmas etapas foram realizadas (restaurações e RU). Foram utilizados os testes ANOVA de duas vias e Tukey (p=0,05). No esmalte, os grupos teste e controle não apresentaram diferença estatística, independentemente dos sistemas adesivos utilizados. Na dentina, o BF apresentou melhores valores de no grupo teste (p=0,04). O fator adesivo foi significativo na análise fatorial (p<0,001) assim como a interação entre desafio erosivo/abrasivo e os sistema adesivo utilizado (p=0,046). Somente o substrato dentinário teve influência significativa na RU (p=0,395). Conclui-se que a RU ao esmalte decíduo não foi afetada pelo desafio erosivo/abrasivo para todos os sistemas adesivos utilizados, enquanto a RU na dentina decídua somente foi afetada pelo sistema adesivo autocondicionante contendo flúor. / The aim of this in vitro study was to evaluate the microshear bond strength of four adhesive systems on eroded or sound primary teeth. Methods: Ninety-six primary molars were cut mesio-distally, embedded, ground and polished with SiC papers (600, 1200, 2400 and 4000). Specimens were randomly divided according to 4 adhesive systems: SB (Adper Single Bond2®), SBU (Universal Single Bond®), OBFL (OptibondFL®) and BF (BondForce®). Half of the specimens were exposed to erosive/abrasive challenge, and the other half (control group; n=48) remained immersed in artificial saliva. Erosive challenge consisted of specimen immersion in Coca-Cola® (pH 2.6, 50ml, 1min, 4x, 5 days). Once a day, the specimens were brushed using an electric toothbrush with a slurry (artificial saliva and NaF toothpaste, 1450 ppm) for 1 minute. Polyvinyl siloxane molds with a perforation 0.9 mm in diameter and 1 mm in height were placed over the specimens in order to build restorations with flowable resin composite. The molds were cut with surgical blades and removed to allow for microshear bond strength testing. Bonded specimens were attached to an universal testing machine and a shear load was applied with a steel wire at a crosshead speed of 1.0 mm/min until failure occurred. After the tests in enamel, dentin was exposed and polished to perform the same tests in this substrate. Two-way ANOVA and Tukey tests were performed (p=0.05). Results: No statistically significant difference was found between the eroded and sound enamel for any of the adhesives. BF was statistically significant better in eroded dentin than sound dentin (p=0.04). A factorial analysis indicated that the factor adhesive was significant (p<0.001) as was the interaction between adhesive and erosive tooth wear (p=0.046). Only the dentin substrate had a significant influence on microshear bond strength (p=0.395). Conclusion: Bond strength to primary enamel was not affected by erosive/abrasive challenge for all the adhesives systems, while in primary dentin the bond strength was affected only after the use of self-etch adhesive containing fluoride.
129

Influência da aplicação de um inibidor de metaloproteinases na resistência da união adesiva à dentina radicular

Leitune, Vicente Castelo Branco January 2010 (has links)
O objetivo do presente estudo foi avaliar o efeito da aplicação de clorexidina após o condicionamento ácido na preservação da camada híbrida, avaliando a resistência de união imediata e a longo prazo de pinos de fibra de vidro cimentados à dentina radicular. Setenta e dois dentes unirradiculares superiores humanos foram selecionados. Os canais radiculares foram alargados para receberem os pinos de fibra de vidro e aleatoriamente divididos em três grupos (n=24). No Grupo Controle (Gcontrol), o pino de fibra de vidro foi cimentado de acordo com as instruções do fabricante, utilizando um sistema adesivo convencional de três passos e um cimento resinoso dual. Os grupos tratados com digluconato clorexidina GCHX0.2 e GCHX2 receberam a aplicação de solução de clorexidina 0,2% e 2%, respectivamente, após o condicionamento com ácido fosfórico e os pinos foram cimentados utilizando o mesmo sistema adesivo e cimento utilizados no Gcontrol. As raízes foram seccionadas transversalmente ao longo eixo do dente, em fatias de 0,68 (± 0,09) mm. Metade dos dentes foi submetida ao ensaio de push-out após 24 horas e a outra metade, após seis meses de armazenamento em água destilada, a 37°C. Os valores foram analisados com ANOVA de duas vias e teste de comparações múltiplas de Tukey, com nível de significância de 5%. A aplicação de clorexidina não influenciou a resistência de união quando os dentes foram avaliados no mesmo período de armazenagem (p>0,05). O tempo de armazenamento diminuiu significativamente a resistência de união de 24 horas para 6 meses, em todos os grupos (p<0,05). A aplicação de clorexidina não preveniu significativamente a degradação da resistência de união de pinos de fibra cimentados em raízes de dentes humanos, após seis meses de armazenamento. / Introduction: This study evaluated the effect of chlorhexidine applied after dentin phosphoric acid etching on hybrid layer preservation, analyzing the immediate and long-term bond strength of a fiber post cemented to root dentin. Methods: Seventy-two single-rooted, human upper teeth were selected for analysis. Root canals were enlarged for fiber post cementation and were randomly divided into three groups (n= 24). After phosphoric acid etching, each group received a different dentin treatment. In the Control Group (Gcontrol), the fiber post was cemented according to the manufacture’s instruction, using a three-step etch-and-rinse adhesive and a dual-cured resin cement. The Chlorhexidine 0.2% Group (GCHX 0.2) and the Chlorhexidine 2% Group (GCHX 2) received an application of a chlorexidine digluconate solution of 0.2% and 2%, respectively, after phosphoric acid etching, and the post was cemented using the same adhesive and cement that was used in the Gcontrol. Teeth were sectioned transversally in slices of 0.68 (± 0.09) mm. Half of the teeth were submitted to push-out bond strength after 24 hours and the other half were submitted after six months of distilled water storage at 37°C. Data were analyzed by using the two-way analysis of variance (ANOVA) and a post hoc tests using the Tukey multiple comparison test at α = 0.05. Results: Chlorhexidine application had no influence on bond strength when teeth were stored for the same period of time (p>0.05). The storage time significantly decreased the bond strength values of 24 hours to six months, in all groups (p<0.05). Conclusion: After six months, chlorhexidine application did not effectively arrest bond strength degradation of fiber post cemented in human roots.
130

Evaluation of Push-Out Bond Strengths of Three Root Canal Sealers / AvaliaÃÃo da forÃa de adesÃo de trÃs cimentos endodÃnticos pelo mÃtodo do push-out

Walter Cavalcante SÃ Neto 31 July 2012 (has links)
nÃo hà / The main aim of endodontic therapy is the cleaning and shaping of the root canal and the complete filling of the entire root canal system. Adhesion is defined as the atomic or molecular attraction between two surfaces that touch, caused by the interfacial force of attraction between the molecules or atoms of both materials. The adhesion can be chemical, mechanical or a combination of both. The perfect adhesion of the filling to the canal walls is a constant search through the improvement and introduction of new materials used in this phase of treatment, with emphasis on the sealer that promotes the union of the solid part of the filling, gutta-percha, to the walls of the root canal. This study aimed to evaluate the bond strength of three root canal sealers by the push-out test, that is quite reliable in view of the accuracy and reproducibility of results. Thirty human upper canines teeth were selected and sectioned at the cementoenamel junction to remove the crown and 2 mm from the apex. All canals were enlarged with Gates-Glidden drills #1-5 and finished the preparation with Peeso drill #6. Between every drill exchange, 1 ml of 2.5% sodium hypochlorite was used as irrigating solution. The roots were sectioned in 1 mm slices and filled according to the root canal sealer, subdividing each group according to the root third (n=25). They were then filled with the sealer as follow: Group 1, AH Plus, Group 2, MTA Fillapex and Group 3 Pulp Canal Sealer. The results showed statistically significant superiority of the AH Plus compared to the other two sealers and Pulp Canal Sealer in relation to the MTA Fillapex. Regarding the root thirds, only the Pulp Canal SealerÂs group showed statistically significant differences, with superiority of the apical third compared to cervical and middle thirds. It is concluded that AH Plus showed the best values of bond strength, regardless of the root third. / Os principais objetivos do tratamento endodÃntico sÃo a limpeza, a modelagem do canal radicular e a completa obturaÃÃo de todo o sistema de canais radiculares. Uma das propriedades exigidas do material obturador à a adesÃo, que à definida como a atraÃÃo molecular ou atÃmica entre duas superfÃcies que se tocam, causada pela forÃa de atraÃÃo interfacial existente entre as molÃculas ou Ãtomos de dois materiais. A adesÃo pode ser quÃmica, mecÃnica ou a combinaÃÃo de ambas. A perfeita adesÃo da obturaÃÃo Ãs paredes do canal à uma busca constante atravÃs do aprimoramento e lanÃamento de novos materiais utilizados nessa fase do tratamento, com Ãnfase no cimento endodÃntico, responsÃvel pela uniÃo da parte sÃlida da obturaÃÃo, a guta percha, Ãs paredes do canal radicular. Este estudo teve como objetivo avaliar a forÃa de adesÃo de trÃs cimentos endodÃnticos atravÃs do teste de push-out, que à um teste bastante confiÃvel, tendo em vista a precisÃo dos resultados e sua reprodutibilidade. Trinta caninos superiores humanos extraÃdos foram selecionados e seccionados na junÃÃo cemento-esmalte, descartando-se a coroa e removendo-se 2mm do Ãpice radicular. Em seguida, os canais radiculares foram preparados com brocas de Gates-Glidden #1 a 5 e finalizados com a broca de Peeso #6, gerando um preparo do canal radicular de forma cilÃndrica e com 1,5 mm de diÃmetro. Logo apÃs, as raÃzes foram seccionadas transversalmente em fatias de 1mm de altura, sendo logo apÃs divididas em 3 grupos de acordo com o cimento utilizado e 3 sub grupos, de acordo com o terÃo radicular (n=25). Os espÃcimes foram entÃo preenchidos com o cimento da seguinte forma: Grupo 1, cimento AH Plus, Grupo 2, cimento MTA Fillapex e Grupo 3, cimento Pulp Canal Sealer. Os resultados mostraram superioridade com diferenÃa estatisticamente significante do cimento AH Plus em relaÃÃo aos outros dois cimentos e do Pulp Canal Sealer em relaÃÃo ao MTA Fillapex. Em relaÃÃo aos terÃos radiculares, somente no grupo do Pulp Canal Sealer foram encontradas diferenÃas estatisticamente significantes, com superioridade do terÃo apical em relaÃÃo aos terÃos cervical e mÃdio. Conclui-se que o cimento AH Plus apresentou os melhores valores de forÃa de adesÃo, independente do terÃo radicular.

Page generated in 0.0571 seconds