• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 73
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 6
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 75
  • 62
  • 42
  • 35
  • 29
  • 28
  • 21
  • 20
  • 20
  • 19
  • 18
  • 17
  • 15
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação de enxaguatório bucais na atividade biológica do biofilme formado em braquetes ortodônticos / Evaluation of oral Rinses in biological activity of biofilm formed in orthodontic brackets

Bussadori, Celene Marques 25 September 2013 (has links)
Na Odontologia, existe uma grande preocupação com a formação de placa bacteriana ou biofilme devido ao seu potencial cariogênico. Essa atenção se estende à ortodontia, devido ao acúmulo de biofilme formado nos aparelhos ortodônticos, tanto nos aparelhos removíveis quanto nos aparelhos fixos. É muito comum a presença de lesões brancas após a remoção dos bráquetes, em torno de 50 a 75% dos pacientes, provocadas pela presença do biofilme. É necessário um controle químico e mecânico rigoroso, a fim de se evitar alterações irreversíveis nos dentes e periodonto. O controle mecânico se dá pela escovação adequada, pelo correto uso de fio dental e pela frequência desses hábitos, além, claro, de um acompanhamento profissional periódico. O controle químico pode ser viabilizado pelo uso de enxaguatórios bucais, nos quais residem alguns efeitos indesejáveis e contraindicações relacionadas ao uso e à idade dos pacientes. Este estudo tem como objetivo avaliar comparativamente dois enxaguatórios bucais, um de natureza comercial (Cepacol®), e outro não comercial, elaborado com extratos hidroalcoólicos das plantas Nasturtium officinale (agrião), Rosmarinus offinalis (alecrim), Tabebuia impetiginosa (ipê roxo), Achillea millefolium (mil folhas) e Plantago major (tanchagem), desenvolvido na Faculdade de Ciências Farmacêuticas/UNESP Araraquara. Foram selecionados 40 pacientes, jovens e adultos, entre 18 e 45 anos, usuários de aparelho ortodôntico corretivo (fixo), divididos em dois grupos, o grupo do Cepacol e o grupo do Enxaguatório base de plantas. Foram coletadas amostras nos períodos de 0, 7, 15 e 21 dias e analisadas observando-se as Unidades Formadoras de Colônia (UFC) de cada amostra. Houve uma queda significativa da quantidade de bactérias após o uso do Enxaguatório à base de plantas, revelando um produto de extrema utilidade no auxílio do controle do biofilme bacteriano nas superfícies dentárias. / In dentistry, there is a great concern with the formation of plaque or biofilm, due to its cariogenic potential. This attention extends to orthodontics due to the accumulation of biofilm on orthodontic appliances, removable appliances as much in the brackets. It is very common the presence of white spots after removal of the brackets, around 50 to 75% of patients, which are caused by biofilms. It takes a rigorous mechanical and chemical control in order to avoid irreversible changes in the teeth and periodontium. The mechanical control is by proper brushing, correct flossing and also the frequency of these habits, besides, of course, a periodical professional monitoring. Chemical control can be achieved by the use of mouthwashes, home to some undesirable effects and contraindications related to the use and age of patients. This study aimed to assess two mouthwashes, a commercial type (Cepacol ®) and other non-commercial, made with hydroalcoholic extracts of plants Nasturtium officinale (watercress), offinalis Rosmarinus (rosemary), Tabebuia impetiginosa ( purple ipe), Achillea millefolium (thousand leaves) and Plantago major (plantain), developed at the Faculty of Pharmaceutical Sciences / UNESP Araraquara. We selected 40 patients, young and adults between 18 and 45 years, users of orthodontic appliance (fixed), divided into two groups, the Cepacol group and the group of herbal mouthwash. Samples were collected during periods of 0, 7,15 and 21 days and analyzed by observing the Colony Forming Units (CFU) of each sample. There was a significant decrease in the amount of bacteria after using herbal mouthwash, revealing a product of the utmost use in aiding the control of bacterial biofilms on tooth surfaces.
22

Preferência e percepção do desconforto por pacientes adultos submetidos a tratamento ortodôntico com bráquetes convencionais e autoligáveis : um estudo clínico randomizado split-mouth /

Shibasaki, Wendel Minoro Muniz January 2019 (has links)
Orientador: Renato Parsekian Martins / Resumo: Introdução: O ortodontista necessita ponderar entre a melhor evidência científica disponível, a sua experiência profissional e as preferências do paciente para a tomada de decisão clínica. A decisão entre bráquetes autoligáveis (BA) ou convencionais (BC) pode ser fundamentada com estudos comparando sua eficiência clínica e aspectos profissionais de manuseio dos bráquetes, mas poucos estudos abordam as percepções do paciente e nenhum compara e quantifica a preferência e a percepção de desconforto dos pacientes, distinguindo-a da sensibilidade dolorosa. Um estudo clínico randomizado e controlado split-mouth de centro único foi conduzido com esse objetivo. Métodos: Vinte e seis participantes com média de 28,8(11,5) anos, com má oclusão simétrica, foram convocados para participar da pesquisa. Cada paciente teve um hemiarco superior randomizado para instalação de BA, enquanto o hemiarco contralateral era instalado os BC, ao mesmo tempo (T0). O cegamento apenas foi possível para o pesquisador. A preferência foi consultada após 30 dias e quantificada pela técnica willigness-to-pay (WTP), enquanto o nível de desconforto foi medido por escala visual analógica (EVA) antes da instalação(T0), imediatamente após a instalação (T1), 7 dias após a instalação (T2) e 30 dias após a instalação e com fio amarrado (T3). Índices de placa (IP) e gengival(IG) foram feitos em T0 e T3. Resultados: Os pacientes percebem diferença entre os modelos usados. Ao final, 17 pacientes preferiram os bráquetes c... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: ABSTRACT Introduction: The orthodontist needs to balance between the best available scientific evidence, his professional experience and the patient's preferences for clinical decision-making. The decision between self-ligating (SLB) or conventional (CB) brackets can be based on studies comparing their clinical efficiency and professional aspects of bracket manipulation, but few studies address the patient's perceptions and none compares and quantifies preference and perception of discomfort of patients, distinguishing it from pain sensitivity. A single-center, randomized, controlled split-mouth trial was conducted with this goal. Methods: Twenty-six participants with a mean age of 28.8 (11.5) years with symmetric malocclusion were invited to participate in the study. Each patient had a superior hemiarch randomized to bonding SLB, while the contralateral hemiarch had CB bonded at the same time (T0). Blinding was only possible for the researcher. The preference was consulted after 30 days and quantified by the willigness-to-pay (WTP) technique, while the level of discomfort was measured by visual analogue scale (VAS) before bonding (T0), immediately after bonding (T1), 7 days after bonding (T2) and 30 days after bonding and with wire tied (T3). Plaque and gingival index were made in T0 and T3. Results: Patients perceive difference between the models used. In the end, 17 patients preferred the conventional, while 9 preferred the self-ligation brackets. Patients who chose CBs we... (Complete abstract click electronic access below) / Doutor
23

Análise on vitro da estabilidade de cor e rugosidade superficial de braquetes ortodônticos cerâmicos /

Oliveira, Cibele Braga de. January 2012 (has links)
Orientador: Luiz Gonzaga Gandini Junior / Banca: Ary dos Santos-Pinto / Banca: Antonio Carlos de Oliveira Ruellas / Resumo: Este estudo objetivou analisar, in vitro, a estabilidade de cor e rugosidade superficial de braquetes cerâmicos após imersão em soluções corantes. Sete braquetes cerâmicos de incisivo central superior direito de quatro marcas comerciais foram testados: dois monocristalinos e dois policristalinos. Os braquetes foram imersos em quatro soluções corantes (café, vinho tinto, Coca-Cola e chá preto) e em saliva artificial separadamente nos seguintes tempos: T0 (mensuração inicial), T1, T2, T3 e T4 (24 horas, 7,14 e 21 dias respectivamente).Outros sete braquetes de cada marca comercial foram imersos nas mesmas soluções e em tempos iguais aos anteriores, porém com intervalos de escovação diários. As alterações de cor foram avaliadas por espectrofotômetro de reflectância e a rugosidade superficial por meio de um Rugosímetro. Os dados foram avaliados pela Análise de Perfis Multivariados, Análise de Variância (ANOVA), teste de comparação múltipla de médias e Teste t de Student. Com base nos resultados, houve alteração perceptível de cor em todos os braquetes cerâmicos após 21 dias de imersão nas soluções de café (ΔE do Allure = 7,61, Inspire Ice = 6,09, Radiance=6,69, Transcend=7,44), chá preto (ΔE do Allure = 6,24, Inspire Ice = 5,21, Radiance=6,51, Transcend=6,14) e vinho tinto (ΔE do Allure =6,49 , Inspire Ice = 4,76, Radiance=5,19, Transcend=5,64), porém a alteração não foi perceptível para a Coca-Cola e saliva artificial (ΔE<3,7). Os braquetes submetidos à escovação apresentaram médias de alteração de cor significativamente menores e não perceptíveis, exceto para o chá preto. Rugosidade: Média Ra do Allure =0,277, Inspire Ice =0,262, Radiance=0,177, Transcend=0,367. A rugosidade variou apenas com o tempo de imersão. Cocluiu-se que houve alteração de cor dos braquetes cerâmicos quando imersos nas soluções, porém, apenas com o café... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to analyze in vitro the color stability and surface roughness of ceramic brackets after immersion in dye solutions. Seven ceramic brackets, upper right central incisor of four commercial brands were tested: two monocrystalline and two polycrystalline. The brackets were immersed separately in four staining solutions (coffee, red wine, Coca-Cola and black tea) and in artificial saliva at following times: T0 (initial measurement), T1, T2, T3 and T4 (24 hours, 7.14 and 21 days respectively). Other seven brackets of each brand were immersed in the same solutions and at same times as previous, but with brushing daily. The changes in color were evaluated by reflectance spectrophotometer and the surface roughness by a surface roughness gauger. The data were evaluated by Multivariate Analysis Profiles, Analysis of Variance (ANOVA), Multiple Comparison Test of means and Test t Student. Based on the results, there was perceptible change of color in all ceramic brackets after 21 days of immersion in coffee solution (ΔE of Allure = 7.61, Inspire Ice = 6,09, Radiance=6,69, Transcend=7,44), black tea (ΔE of Allure = 6,24, Inspire Ice = 5,21, Radiance=6,51, Transcend=6,14) and red wine (ΔE do Allure =6,49 , Inspire Ice = 4,76, Radiance=5,19, Transcend=5,64), but the change was not perceptible to the Coca-Cola and artificial saliva (ΔE <3.7). The brackets that were submitted to brushing showed average color change significantly smaller and not visible, except for black tea. Roughness: Ra Average of Allure = 0.277, Inspire Ice = 0.262, Radiance = 0.177, Transcend = 0.367. The roughness changed with the immersion time. It was cocluded that there was a change in color of ceramic brackets when immersed in the solutions, but only with coffee, black tea and red wine that change was perceptible. The monocrystalline or polycrystalline structure doesn't affect in the form of staining... 9Complete abstract click electronic access below) / Mestre
24

Avaliação da resistência ao Cisalhamento de braquetes novos recolocados com diferentes resinas ortodônticas / Evaluation of shear bond strength of new metallic brackets rebounded with different orthodontic resins

Jimenez, Emigdio Enrique Orellana 04 December 2007 (has links)
Made available in DSpace on 2017-07-24T19:22:06Z (GMT). No. of bitstreams: 1 Emigdio Enrique Orellana Jimenez.pdf: 1399808 bytes, checksum: 9a5dfb23c60c52032fb9609d09fd87ca (MD5) Previous issue date: 2007-12-04 / The present study evaluated in vitro the shear bond strength of new bonded and rebounded metallic brackets with three orthodontic composites. Ninety extracted first superior premolars were randomly divided in three groups, according to the different tested composite. All bonding procedures followed the manufacturer’s specifications with a 300g standard pressure over the bracket during positioning. Alpha plast (AP), Concise (CO) and Transbond XT (TB) were the evaluated composites. For each group, three shear bond strength examinations were performed in three different times, initial (T0), first rebonding (T1) and second rebonding (T2), with a 24 hour interval between them. The tests were performed with a SHIMADZU AG-I, (10KN) machine with a 0,5 mm/min cross-head speed and the fracture strength was recorded in Megapscal (MPa) considering brackets base area. The mean shear bond strength was evaluated and the adhesive remnant index (ARI) was scored. The results showed that in T0 the groups AP and CO presented similar and higher values than TB, in T1 and T2 the highest shear bond strength values were found in group AP, followed by group CO and TB. Those data were submitted to two-way ANOVA and Tukey´s and Bonferroni´s test (p<0,05) and the ARI results were analyzed by the Kruskal Wallis test followed by the Dunn´s test. It was found a statistical significant difference (p<0,05) in shear bond strength between groups but not between the different bonding and rebonding times. The highest shear bond strength values were observed in the group AP, followed by CO and TB. In relation to ARI, it was noticed a significant statistical difference (p<0,05) between the groups, and the TB presented higher values (p<0,05) than those verified in AP and CO, for T0 and T2. It was concluded that repeated bondings with new brackets presented an adhesive difference in shear bond strength considering the utilized composite, however, at bonding and rebonding with the same composite, there are no significant differences. / Este estudo avaliou in vitro a resistência ao cisalhamento de braquetes metálicos novos colados e recolados com três resinas ortodônticas. Foram utilizados 90 primeiros pré-molares superiores humanos extraídos para a confecção dos corpos de prova, os quais foram divididos aleatoriamente em três grupos;(n = 30) de acordo com a resina utilizada. Todos os procedimentos de colagem seguiram as recomendações do fabricante com uma pressão padronizada em 300g. Foram utilizadas as resinas Alpha Plast (AP), Concise (CO) e Transbond XT (TB). Para cada um dos grupos foram realizados três ensaios de cisalhamento em três tempos, um inicial (T0) e os outros dois T1 e T2, primeira e segunda recolagens, respectivamente, com intervalos de 24 horas. Os testes de cisalhamento foram realizados em uma máquina eletrônica de ensaios eletromecânicos SHIMADZU AG-I, (10KN), com velocidade de pressão de 0,5mm/min e carga de ruptura registrada em Megapascal (MPa). Considerando a área da base do braquete, foram mensuradas as resistências médias ao cisalhamento e o índice de adesivo remanescente (IAR). Os resultados demonstraram que para T0 os grupos AP e CO apresentaram valores próximos e superiores a TB, para T1 e T2 os maiores valores de resistência foram observados para o grupo AP, seguido dos grupos CO e TB. Estes dados foram submetidos à ANOVA 2 critérios e ao teste de Tukey e de Bonferroni (p<0,05) e para o IAR o teste Kruskal Wallis, seguido de teste Dunn. Existe diferença estatística significante (p<0,05) na resistência ao cisalhamento (MPa) entre os grupos mas não entre os tempos de colagem e recolagem de braquetes novos, sendo que os maiores valores de resistência ao cisalhamento foram encontrados no grupo AP, seguido de CO e TB. Em relação ao IAR, existiu diferença estatisticamente significante (p<0,05) entre os grupos, o grupo TB foi estatisticamente superior (p<0,05) aos grupos AP e CO, para o T0 e T2. Concluiu-se que colagens repetidas com braquetes novos apresentam diferença adesiva de resistência ao cisalhamento considerando a resina utilizada, porém na colagem e recolagens com a mesma resina não há diferenças significativas.
25

Avaliação da resistência ao cisalhamento de braquetes colados com resinas ortodônticas fluoretadas

Rastelli, Márcia Cristina 22 February 2006 (has links)
Made available in DSpace on 2017-07-24T19:22:14Z (GMT). No. of bitstreams: 1 MarciaCristinaR.pdf: 1130793 bytes, checksum: 7d9d617dfc4b2b8f59066d8b013a6268 (MD5) Previous issue date: 2006-02-22 / The aim of this study was to evaluate the shear bond strength of brackets bonded with fluoride-releasing composite resins, and to compare them to a conventional resin. For this study, sixty premolars extracted due to orthodontic reasons were used, which were divided into three groups: Group 1- Concise (3M), Group 2- Ultrabond (Aditek do Brasil) and Group 3- Rely-a-bond (Reliance). All bonded specimens were stored in distilled water at 37°C for 24 hours and termocycled between 5°C and 55°C for 500 cycles. After 48 hours, the specimens were submitted to the shear bond strength test, in occluso-gingival direction, in Material Test System MTS 810 machine, with load speed of 0.5 mm/min. Variance Analysis, Levene Test, Shapiro-Wilk Test and Tukey Test were used for data analysis. The results demonstrated a mean shear bond strength of 24.54 ± 6.98 MPa for the Concise; 11.53 ± 6.20 MPa for the Ultrabond; and of 16.46 ± 5.72 MPa for the Rely-a-Bond. Variance Analysis determined a statistical difference amongst groups (p<0.001). Tukey Test evidenced that the averages of the three groups were significantly different among themselves (p<0.05), with the highest resistance for the Concise Group and the lowest for the Ultrabond Group. However, all the materials presented bond strengths, which were suitable for clinical use. / O objetivo deste estudo foi avaliar a resistência ao cisalhamento de braquetes colados com resinas que contém flúor, e compará-las a uma resina convencional. Para este estudo, foram utilizados 60 pré-molares extraídos por motivo ortodôntico, os quais foram divididos em 3 grupos, sendo 20 corpos-de-prova para cada um: Grupo I - Concise (3M), Grupo II – Ultrabond (Aditek do Brasil) e Grupo III - Rely-a-Bond (Reliance). Todos os corpos-de-prova foram armazenados em água destilada a 37°C, por 24 horas e termociclados com 500 ciclos, nas temperaturas de 5°C e 55°C. Após 48 horas, os corpos-de-prova foram submetidos aos ensaios mecânicos de cisalhamento na direção ocluso-cervical, na máquina Material Test System MTS 810, com velocidade de carga de 0,5 mm/min. Para a análise dos dados, utilizou-se a Análise de Variância, Teste de Levene, Teste de Shapiro-Wilk e o Teste de Tukey. Os resultados demonstraram uma resistência média ao cisalhamento de 24,54 ± 6,98 MPa para o Grupo I (Concise), de 11,53 ± 6,20 MPa para o Grupo II (Ultrabond) e de 16,46 ± 5,72 MPa para o Grupo III (Rely-a-Bond). A Análise de Variância determinou diferença estatística entre as médias de resistência ao cisalhamento entre os grupos (p<0,001). O teste de Tukey evidenciou que as médias dos três grupos foram significativamente diferentes entre si (p<0,05), com a maior resistência para o Grupo I (Concise) e a menor para o Grupo II (Ultrabond). Entretanto, todos os materiais apresentaram resistência adesiva adequada para uso clínico.
26

Avaliação "in vitro" da resistência adesiva ao cisalhamento na colagem de braquetes usando dois tipos de resina

Meister, Edison do Rocio 30 July 2004 (has links)
Made available in DSpace on 2017-07-24T19:22:26Z (GMT). No. of bitstreams: 1 Edison do Rocio Meister.pdf: 461572 bytes, checksum: e1fe440febb5495ebe6ab7799100cc75 (MD5) Previous issue date: 2004-07-30 / This research aims to evaluate the shear bond strenght of two resins for direct orthodontic bonding to human teeth: Concise (3M) and Ortho One (Bisco). The sample consisted in 60 caries-free premolars, which were randomly divided in two groups: group A (30 premolars with brackets bonded with Concise) and group B (30 premolars with brackets bonded with Ortho One). All teeth showed intact enamel at the vestibular surface and were extracted for orthodontic reasons, from patients aging between 11 and 16 years old. The bonding procedures were accomplished according to the manufacturer’s instructions. The specimens were submitted to shear bond strenght tests, using an occlusal-cervical load. The tests were carried out in an universal eletronic machine for mechanical assays (MTS 810), with deformation speed of 0,5 mm/min and rupture load registered in megapascal (MPa). The results obtained for group A showed a mean resistance of 29,99 + 15,89 MPa, while for the grupo B, the values demonstrated a mean resistance of 22,52 + 12,26 MPa. These results suggest that Concise orthodontic resin is more effective than Ortho One orthodontic resin when shear bond strength is considered. / O objetivo desta pesquisa foi avaliar a resistência ao cisalhamento na colagem de braquetes metálicos específicos para pré-molares, comparando as resinas, Concise Ortodôntico (grupo controle) e a resina Ortho-one (grupo experimental). Fizeram parte deste estudo, 60 pré-molares humanos superiores e inferiores extraídos, por finalidade ortodôntica. Os dentes foram divididos aleatoriamente para os dois grupos, controle e experimental, cada um com 30 amostras. O procedimento de colagem ortodôntica foi realizado seguindo rigorosamente as instruções de cada fabricante Os testes de resistência ao cisalhamento foram realizados em uma máquina eletrônica universal para ensaios mecânicos “Material Test System” M T S 810, com velocidade de deformação de 0,5 mm/min e carga de ruptura registrada em Megapascal (MPa). O grupo controle apresentou uma resistência média de 29,99 MPa (±15,89), enquanto que para o grupo experimental uma resistência média de 22,52 MPa (±12,26). Os resultados obtidos foram submetidos ao teste estatístico “t” e determinada uma diferença estatisticamente significativa para o grupo controle. Estes resultados sugerem que a resina Concise Ortodôntico apresenta maior resistência ao cisalhamento que a resina Ortho-One.
27

Avaliação laboratorial de materiais e técnicas utilizados em ortodontia / Laboratory evaluation of materials and techniques used in orthodontics

Oliveira, Adauê Siegert de 23 October 2015 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-12T13:15:01Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Avaliação laboratorial de materiais e técnicas utilizados em Ortodontia.pdf: 23257773 bytes, checksum: 8ebe2d1533573ee98e16abdd1d133f28 (MD5) / Made available in DSpace on 2017-06-12T13:15:01Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Avaliação laboratorial de materiais e técnicas utilizados em Ortodontia.pdf: 23257773 bytes, checksum: 8ebe2d1533573ee98e16abdd1d133f28 (MD5) Previous issue date: 2015-10-23 / Sem bolsa / A evolução dos materiais ortodônticos facilitou a prática clínica, difundiu a especialidade e popularizou os tratamentos. Propiciar tratamentos mais rápidos, sem prejuízo estético, confortáveis ao paciente e minimizando efeitos colaterais são os maiores objetivos das pesquisas nessa especialidade. Diversos fatores clínicos motivam, constantemente, novos estudos para desenvolvimento e evolução dos materiais associados à técnica. A exigência estética direciona o aprimoramento dos braquetes cerâmicos bem como das ligaduras elásticas transparentes. Por outro lado, a forte associação em Ortodontia e Odontopediatria exige que procedimentos ortodônticos em crianças sejam rápidos e eficientes devido ao tempo clínico reduzido. Assim, este estudo buscou contribuir para a evolução desses materiais por meio de estudos in vitro. Os objetivos foram: avaliar in vitro o efeito do tipo de dentifrício utilizado (regular ou clareador) na estabilidade de cor de ligaduras elásticas translúcidas, onde a variável-resposta foi alteração cromática (?E) de acordo com os parâmetros CIEL*a*b* e foi aferida através de espectrofotômetro; analisar as implicações na adesão de braquetes ao esmalte relacionadas a alterações de posicionamento dos braquetes e remoção do excesso de cimento durante a colagem, para isto, foi analisada a resistência de união (MPa) de braquetes metálicos unidos ao esmalte bovino utilizando diferentes protocolos de colagem, tendo como variável-resposta secundária o modo de falha da união; avaliar o efeito da utilização de duas fontes de luz simultâneas durante a fotoativação do cimento ortodôntico na resistência de união de braquetes ao esmalte e avaliar a adição de sal de iodônio a compósitos adesivos fotoativados para reduzir o tempo de fotoativação necessário para colagem de braquetes ortodônticos ao esmalte dentário. / The evolution of orthodontic materials facilitated clinical practice, spread the specialty and popularized treatments. Providing treatments faster, without prejudice aesthetic, comfortable for the patient and minimizing side effects are the major objectives of research in this specialty. Several clinical factors motivate constantly new studies for development and evolution of materials associated with the technique. The aesthetic requirement directs the improvement of ceramic brackets and the transparent elastic bandages. On the other hand, the strong association in Orthodontics and Pediatric Dentistry requires orthodontic procedures in children are fast and efficient due to reduced clinical time. The objectives are to evaluate in vitro effect of the type of toothpaste used (regular or bleaching) on color stability of elastic bandages translucent, where the response variable is color change (?E) according to the parameters CIEL * a * b * and will be measured by a spectrophotometer; analyze the implications for the accession of brackets to enamel related to changes in positioning of the brackets and removing excess cement during bonding, for this, we will analyze the bond strength (MPa) of metal brackets attached to bovine enamel using protocols collage. With the response variable secondary mode joint failure; assess the effect of using two sources of simultaneous light for the photoactivation of orthodontic cement in bracket bond strength to enamel and evaluate the addition of iodonium salt to photoactivated adhesive composite to reduce the time of curing required for bonding of orthodontic brackets to tooth enamel.
28

Efeito da adição de monômeros funcionalizados em um cimento ortodôntico experimental na prevenção de danos ao tecido dental / Effect of functionalized monomers addition in an experimental orthodontic cement to prevent damage to dental tissue

Araújo , Raíssa Coi de 27 July 2016 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-21T12:50:38Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Efeito da adição de monômeros funcionalizados em um cimento ortodôntico.pdf: 1936663 bytes, checksum: 47dd85a59adae3a7b7b5560fd6403dfe (MD5) / Made available in DSpace on 2017-06-21T12:50:38Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Efeito da adição de monômeros funcionalizados em um cimento ortodôntico.pdf: 1936663 bytes, checksum: 47dd85a59adae3a7b7b5560fd6403dfe (MD5) Previous issue date: 2016-07-27 / Sem bolsa / O advento da adesão na Odontologia permitiu o uso de acessórios ortodônticos cimentados diretamente sobre a superfície dental. Com estes procedimentos adesivos, surge um importante questionamento acerca do método mais indicado para a remoção dos bráquetes e desgaste do agente de cimentação remanescente sobre o esmalte dental. Várias são as técnicas propostas no que tange aos instrumentos de remoção, mas a literatura aponta que, independente da técnica, sempre há dano à estrutura dental. O uso de acessórios ortodônticos, associados ao excesso de agente de cimentação ao redor dos bráquetes, possibilita um maior acúmulo de biofilme e, consequentemente, desenvolvimento de cárie ao redor dos acessórios. Assim, este estudo tem o objetivo adicionar metacrilatos metálicos coloridos - cobre e prata - a cimento ortodôntico experimental e avaliá-los quanto a influência da cor dos novos cimentos na identificação dos excessos, previamente à fotoativação do produto, e no desgaste do remanescente após a descimentação dos acessórios ao final do tratamento. Outro objetivo foi avaliar o efeito antimicrobiano produzido pela adição dos metacrilatos contra o Streptococcus mutans, microorganismo fortemente associado à carie dental. Os grupos testados foram: Cimento ortodôntico experimental sem metacrilato metálico (C), Cimento ortodôntico experimental com Metacrilato de Prata (CMAg), Cimento ortodôntico experimental com Metacrilato de Cobre (CMCu) e referências comerciais - cimento ortodôntico convencional (Transbond XT, 3M Unitek, Monrovia, CA, EUA) e resina composta de coloração distinta da estrutura dental (Resina Composta Filtek Z250 XT D3, 3M ESPE, St Paul, MN, USA). Os materiais foram caracterizados quanto ao grau de conversão, propriedades colorimétricas, propriedades físicas, químicas e mecânicas, viabilidade celular e efeito antibacteriano (através de Teste de Difusão e Ágar e Teste de Contato Direto Modificado). O tempo utilizado na cimentação e remoção dos bráquetes foi avaliado e a superfície do esmalte foi caracterizada em microscopia eletrônica de varredura (MEV), bem como a perda estrutural de esmalte, resultante da remoção do agente de cimentação residual, foi avaliada através da Perfilometria 3D (Rugosidade superficial - Sa e volume de esmalte perdido - V). Os procedimentos experimentais de cimentação, remoção e desgaste do remanescente de cimento foram realizados por operador experiente. Para todos os testes foi considerado o valor p<0,05 como estatisticamente significante. Através dos testes realizados, foi possível identificar que os CMCu e CMAg podem ser potencialmente antimicrobianos, uma vez que apresentaram halo de inibição maior que os dos demais grupos. CMCu inibiu o crescimento microbiano no período de 24h, havendo a necessidade de testar este efeito em um período prolongado. Os cimentos coloridos facilitaram a identificação e remoção do material que permaneceu sobre a estrutura dental, reduzindo o tempo de trabalho. / The advent of adhesion in dentistry allowed the use of orthodontic appliances directly cemented on the tooth surface. With these adhesive procedures, an important question about the most appropriate method for debond brackets and for wearing remnant bonding agents on dental enamel arises. There are several methods and instruments used for that purposes, but the literature indicates that, regardless of the technique, there is always damage to tooth structure. The use of orthodontic appliances associated with the excess bonding agent around the brackets allows a biofilm accumulation and thus caries development around accessories. This study aims to add colored metal methacrylates - copper and silver - on experimental orthodontic cement, and evaluate the influence of the color of new cements when identifying excesses prior to photoactivation of the product, and the remaining wear after debonding of accessories at the end of the treatment. Another objective was to evaluate the antimicrobial effect produced by the addition of methacrylates against Streptococcus mutans, a microorganism that is strongly associated to dental caries. The groups tested were experimental orthodontic cement without metal methacrylate (C), experimental orthodontic cement with Silver Methacrylate (CMAg), experimental orthodontic cement with Copper Methacrylate (CMCu) and commercial references - conventional orthodontic cement (TB - Transbond XT, 3M Unitek, Monrovia, CA, USA) and resin composed of distinct coloration of the dental structure (RZ250 - Filtek Z250 XT D3, 3M ESPE, St Paul, MN, USA). The materials were characterized as the degree of conversion, colorimetric properties, physical, chemical and mechanical properties, cell viability and antibacterial effect (through Agar Diffusion Method and Modified Direct Contact Test). The time used in cementing brackets and removal of the remnant bonding agent was evaluated, then the enamel surface was characterized by scanning electron microscopy (SEM), and the structural enamel loss resulting from the removal of the residual bonding agent was evaluated by means of 3D profilometry (surface roughness - Sa and volume of enamel loss - V). Experimental procedures of cementing, removal and wear of the remaining cement were performed by an experienced operator. For all tests it was considered p <0.05 as statistically significant. Through the tests, it was possible to identify that CMCu and CMAg can potentially be antimicrobial, since they showed inhibition zone larger than the other groups. CMCu inhibited microbial growth in the 24 hour period, needing to test this effect in a longer period. Colored cement facilitated the identification and removal of the material that remained on the tooth structure, reducing the working time.
29

Adesão bacteriana em braquetes metálicos com tratamento de superfície : estudo in vitro /

Tupinambá, Rogerio Amaral. January 2014 (has links)
Orientador: Ana Paula Rosifini Alves Claro / Coorientador: Cristiane Aparecida de Assis Claro / Coorientador: Celestino José Prudente Nóbrega / Banca: Rosana Vilela Chagas / Banca: Cristiane Aparecida Pereira Correia / Resumo: A evolução dos acessórios utilizados em Ortodontia, especialmente no desenho e nos materiais empregados na confecção dos braquetes, tem apresentado grandes avanços tecnológicos. A presença dos aparelhos dentários aumenta a possibilidade de adesão bacteriana sobre estas superfícies e assim, o risco à cárie nos pacientes ortodônticos. Modificações na superfície dos braquetes, como o aumento da hidrofobicidade, redução da rugosidade superficial e deposição de filmes, tem sido empregadas como opção para redução da adesão bacteriana. Neste estudo in vitro, filmes de polímero de hexametildisiloxano foram depositados sobre braquetes metálicos convencionais e autoligantes, empregando a técnica PECVD (Deposição Química por Plasma de Rádio Frequência).As amostras foram divididas emquatrogrupos, dois com e dois sem tratamentode superfície. Foram avaliadas a variação da molhabilidade, rugosidade superficial e adesão de biofilme de Streptococos mutans.Os valores obtidos paraadesão de biofilmeforam analisados usando o teste de Kruskal-Wallis e SNK.Os resultados mostraram diferença estatística significante (p ≤0.05) entre os braquetes convencionais com e sem filme e, entre os braquetes convencionais e braquetes autoligantes. Portanto se conclui, que o tratamento de superfície foi efetivo na redução da adesão bacteriana nos braquetes convencionais, se observou também, que os braquetes convencionais apresentaram menor adesão de biofilme que os braquetes autoligantes / Abstract: The evolution of the accessories in Orthodontics,especially in the design and materials used in the brackets manufacture, has exhibited major technological advances.The presence of dental appliances increases the possibility of bacterial adhesionon these surfaces and thus the risk of caries in orthodontic patients. Changes on the brackets surface, asthe increased hydrophobicity, reduced surface roughness and film deposition have been employed asan option for reducing bacterial adhesion. In this in vitro study, hexamethyldisiloxane polymer films were deposited on conventional and self-ligating stainless steel brackets, using the Radio Frequency PECVD technique (Plasma- Enhanced Chemical Vapor Deposition). The samples were divided into four groups according to the surface treatment, two treated and two untreated. The changes in wettability, surface roughness and adhesion of the Streptococcus mutans biofilm were evaluated. The values obtained for biofilm adhesion were analyzed using the Kruskal-Wallis and SNK test. The results showed statistically significant difference (p ≤ 0.05)between conventional brackets before and after surface treatment and between conventional and self-ligating brackets. Therefore it was concluded that surface treatment was effective in reducing bacterial adhesion inconventional brackets, it was also noted that the conventional brackets showed lower biofilm adhesion than self-ligating brackets / Mestre
30

Avaliação de protocolos para colagem de bráquetes cerâmicos e remoção do adesivo remanescente com vistas á preservação da integridade de esmalte dentário/

Vianna, Alexandre Protásio. January 2013 (has links)
Orientador: Edson Alves de Campos / Banca: Ronald de Freitas Paixão / Banca: Patrícia Panizzi Gimenes Sakima / Banca: Luiz Gonzaga Gandini Júnior / Banca: Ary dos Santos-Pinto / Banca: / Resumo: Introdução: Este estudo teve como objetivos: Avaliar a influência de diferentes protocolos de condicionamento do esmalte e de cura luminosa dos sistemas adesivos testados, na resistência da colagem de bráquetes de cerâmica ao cisalhamento; na ocorrência de fraturas de esmalte e na quantidade de adesivo remanescente. Além disso, o Método dos Elementos Finitos foi empregado para analisar como os esforços relativos à descolagem atuaram na superfície do esmalte. Com auxílio da Microscopia eletrônica de varredura, avaliou-se a ação de 05 métodos para remoção da camada de adesivo remanescente quanto às alterações geradas nas características superficiais originais do esmalte e quanto ao tempo de execução dos procedimentos. Material de Método: 40 bráquetes Inspire IceTM, 40 bráquetes ClarityTM e 40 bráquetes GeminiTM foram aleatoriamente colados a 120 pré-molares com faces vestibulares hígidas, seguindo diferentes protocolos de condicionamento do esmalte e de fotopolimerização. Essas colagens foram testadas em ensaio mecânico por cisalhamento e também analisadas pelo método dos elementos finitos. Além disso, 25 molares permanentes com faces vestibulares hígidas passaram pela remoção de camadas padronizadas de adesivo remanescente com 05 métodos diferentes. As superfícies iniciais e finais de cada dente foram avaliadas por meio da microscopia eletrônica de varredura. O tempo gasto na execução de cada procedimento foi também avaliado. Resultados: As colagens com o TPSEP apresentaram menores valores de resistência da colagem ao cisalhamento e não estiveram associadas a fraturas de esmalte. Houve coincidência entre o modo de descolagem dos braquetes e a distribuição dos esforços na superfície do modelo 3D. As menores alterações à superfície do esmalte foram geradas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: The aims of this study were to evaluate the influence of different protocols for enamel acidic etching and for light-curing of the adhesive systems tested about: shear bond strength of ceramic brackets; occurrence of enamel fractures and adhesive remnant index. Finite element method was also used to identify how debonding efforts act on enamel surface. Scanning Electron Microscopy was applied to assess the changes observed on original enamel surface characteristics generated by 05 methods for residual adhesive removal. The chair time related to the 05 methods under study was also evaluated. Material and Methods: 40 Inspire Ice Brackets; 40 Clarity Brackets and 40 metal Brackets (Gemini) were randomly bonded to 120 bicuspides, using different protocols of enamel conditioning and photo-activation. 25 permanent molars were submitted to the removal of standardized adhesive layers, using 05 different methods. Initial and final surfaces were comparatively evaluated by scanning electron microscopy. The procedures chair times were also assessed. Results: Transbond Plus Self-etching Primer promoted bracket bonding with lower shear bond strengths and debonding procedures without enamel fractures. FEM analysis showed coincidence among efforts distribution simulated over the tridimensional model surfaces and the real debonding damages caused on enamel. The multi-blade carbide bur in low hand-piece speed caused lower alterations over enamel original surface. Conclusion: TPSEP seemed to be the adequate method for bracket bonding; metallic bracket bonding showed lower shear bond strength without primer light-curing but it was not true for the ceramic brackets; chair time of the procedure and the final aspect of enamel surface demonstrated... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0443 seconds