• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 73
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 6
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 75
  • 62
  • 42
  • 35
  • 29
  • 28
  • 21
  • 20
  • 20
  • 19
  • 18
  • 17
  • 15
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Laser de CO2 como auxiliar na remoção de bráquetes estéticos cerâmicos / CO2 laser-assisted debonding for esthetic ceramic brackets

Macri, Rodrigo Teixeira 02 May 2012 (has links)
Este estudo avaliou a eficiência do uso do laser de CO2 com comprimento de onda de 10,6 m como auxiliar na remoção de bráquetes estéticos cerâmicos. Para este estudo foram utilizados 105 pré-molares inferiores humanos recentemente extraídos, que receberam irradiações com laser de CO2 antes da descolagem dos bráquetes. Na primeira fase deste estudo, o objetivo foi mensurar e comparar a temperatura no compósito de colagem do bráquete e na câmara pulpar após aplicação do laser de CO2 , para observar a segurança para o esmalte, bem como se a temperatura era suficiente para fragilizar o compósito, facilitando a remoção do bráquete. Nesta etapa foram utilizados 30 pré-molares inferiores recentemente extraídos, sendo que cada um recebeu 4 irradiações com diferentes protocolos de maneira aleatória. Foram testados 12 diferentes protocolos variando o tempo de irradiação (3 e 5s), a duração do pulso (0,01 e 0,03s) e a potência (5, 8 e 10W). Cada protocolo foi utilizado por 10 vezes (n=10), totalizando 120 irradiações. Em todas as irradiações os corpos-de-prova foram imersos em banho térmico com água a 37º C. Foram encontrados 4 protocolos cuja variação da temperatura na polpa foi menor que 5,5º C, portanto compatível com a saúde da polpa. Na segunda etapa do estudo, o objetivo foi avaliar a resistência ao cisalhamento após a aplicação do laser utilizando os protocolos cuja temperatura na polpa não fosse superior a 5,5º C. Setenta e cinco pré-molares inferiores humanos foram divididos em 5 grupos, dos quais um não foi submetido à irradiação, sendo considerado Controle (C). Nos 4 grupos restantes, irradiações foram realizadas como descrito a seguir: Grupo I (potência 5W; tempo de pulso 0,01s; tempo de aplicação 3s), Grupo II (5W; 0,03s e 3s), Grupo III (8W; 0,01s e 3s) e Grupo IV (10W; 0,01s e 3s). Cada grupo foi formado por 15 corpos-de-prova (n=15). Após a descolagem do bráquete foi avaliado o Índice de Remanescente Adesivo (IRA). Após as mensurações e aplicação da Análise de Variância (ANOVA) e do teste de Tukey foi constatado que o único grupo que apresentou diminuição na força de remoção foi o IV (7,33 MPa) em relação ao grupo C (10,81 MPa) sendo assim considerado seguro e eficaz na diminuição da resistência do compósito. / This study evaluates the efficacy CO2 10,6 m laser-assisted debonding esthetic ceramic brackets. For this purpose it was used 105 recently extracted lower human premolars that were irradiated with CO2 laser before debonding. In the first phase, the objectives were to measure and compare the temperature in composite for bracket bonding and at the pulp chamber after CO2 laser irradiation, to observe the safety for enamel, as well the temperature was enough to softening the composite, making debonding bracket easier. In this part it was used 30 lower premolar recently extracted, and each one received 4 irradiations with different protocols, randomly choose. It was tested 12 different protocols varying time of irradiation (3 and 5s), pulse duration (0,01s e 0,03s) and power (5, 8 and 10W). Each protocol was repeated for 10 times (n=10), resulting 120 irradiations. In every irradiation the teeth tested were immerse in warm water bath at 37o C. It was found 4 protocols with pulp temperature lower than 5,5º C, so this is compatible with pulp health. In the second phase of this study, the objective was to evaluate the shear bond strength after laser irradiation, using the protocols with pulp chamber temperatures lower than 5,5º C. Seventy-five lower human premolars was shared in 5 groups. One group did not receive laser irradiation and considered Control (C) and the other groups the irradiation was made as it follows: Group I (power density 5W; pulse duration 0,01s; irradiation time 3s), Group II (5W; 0,03s, 3s), Group III (8W; 0,01s; 3s) and Group IV (10W; 0,01s; 3s). After results ANOVA and Tukey tests were made. Group IV presented lowering in SBS force (7,33 MPa) when compared with C (10,81MPa). This protocol was founded as a safe and efficient in softening composite layer.
32

AVALIAÇÃO DA FORÇA DE ATRITO ESTÁTICO EM BRAQUETES AUTOLIGADOS E CONVENCIONAIS ESTUDO IN VITRO / EVALUATE OF THE STATIC FRICTION FORCE IN SELFLIGATING AND CONVENTIONAL BRACKETS IN VITRO STUDY

Oliveira, Luiz Felipe Durand de 28 February 2011 (has links)
The aim of this study was to evaluate, by means the axial pull-out strength, the influence of using conventional metal brackets and metal and ceramic self-ligating, in the intensity of the frictional force generated when associated with orthodontic wires of circular and rectangular sections of different diameters. Three types of brackets were used in this work: metallic conventional (G1); metallic self-ligating (G2) and ceramic self-ligating (G3). Bars were made of polyethylene (10 cm long x 3.5 cm thick x 3.5 cm wide) where three brackets were bonded (canine, first and second premolars rights) previously aligned and leveled. The groups of brackets were associated with orthodontic wires, stainless steel (Cr-Ni) of circular and rectangular sections in three dimensions, F1: 0.020" circular, F2: 0.017 x 0.025 , F3: 0.019" x 0.025" rectangular, resulting Groups: G1F1, G1F2, G1F3, G2F1, G2F2, G2F3, G3F1, G3F2 and G3F3. For each type of bracket were prepared 10 specimens. All groups were tested in a universal testing machine (EMIC DL 2000). easurements of friction were obtained every 0.5 mm distance to travel a total of 5 mm. The values found were submitted to the analysis of Kruskal-Wallis and Tukey. The results showed that self-ligating brackets showed lower friction resistance when compared to conventional brackets used with circular and rectangular wire sections. The differences in the values of the friction encountered between conventional and selfligating brackets have a direct influence of association with the section of wire used. / O objetivo deste estudo foi avaliar, por meio de ensaio de tração, a influência do uso de braquetes convencionais metálicos e autoligados metálicos e cerâmicos, na intensidade da força de atrito gerado, quando associados a fios ortodônticos de secções circular e retangular em diferentes diâmetros. Três tipos de braquetes foram utilizados neste trabalho: convencional metálico (G1); autoligado metálico (G2) e cerâmico (G3). Foram confeccionados barras em polietileno (10 cm de comprimento x 3,5 cm de espessura x 3,5 cm de largura) onde foram colados três braquetes (canino, primeiro e segundo pré-molares superiores direitos) previamente alinhados e nivelados. Os grupos de braquetes foram associados a fios ortodônticos de aço inoxidável (Cr-Ni) de secções circulares e retangulares de três dimensões, F1: 0.020 circular; F2: 0.017 x 0.025 , F3: 0.019 x 0.025 retangulares, originando os grupos: G1F1, G1F2, G1F3, G2F1, G2F2, G2F3, G3F1, G3F2 e G3F3. Para cada tipo de braquetes foram confeccionados 10 corpos de prova. Todos os grupos foram testados em uma máquina de ensaios universais (Emic DL 2000) . As mensurações do atrito foram obtidas a cada 0,5 mm de deslocamento até percorrer um total de 5 mm. Os valores achados foram submetidos as análises de Kruskal-Wallis e Tukey. Os resultados demonstraram que os braquetes autoligados apresentaram menor resistência ao atrito em relação aos convencionais quando utilizados com fios de secções circular e retangular. As diferenças nos valores do atrito estático encontradas entre os braquetes autoligados e convencionais possuem influência direta com a secção e espessura do fio utilizado.
33

Avaliação de enxaguatório bucais na atividade biológica do biofilme formado em braquetes ortodônticos / Evaluation of oral Rinses in biological activity of biofilm formed in orthodontic brackets

Celene Marques Bussadori 25 September 2013 (has links)
Na Odontologia, existe uma grande preocupação com a formação de placa bacteriana ou biofilme devido ao seu potencial cariogênico. Essa atenção se estende à ortodontia, devido ao acúmulo de biofilme formado nos aparelhos ortodônticos, tanto nos aparelhos removíveis quanto nos aparelhos fixos. É muito comum a presença de lesões brancas após a remoção dos bráquetes, em torno de 50 a 75% dos pacientes, provocadas pela presença do biofilme. É necessário um controle químico e mecânico rigoroso, a fim de se evitar alterações irreversíveis nos dentes e periodonto. O controle mecânico se dá pela escovação adequada, pelo correto uso de fio dental e pela frequência desses hábitos, além, claro, de um acompanhamento profissional periódico. O controle químico pode ser viabilizado pelo uso de enxaguatórios bucais, nos quais residem alguns efeitos indesejáveis e contraindicações relacionadas ao uso e à idade dos pacientes. Este estudo tem como objetivo avaliar comparativamente dois enxaguatórios bucais, um de natureza comercial (Cepacol®), e outro não comercial, elaborado com extratos hidroalcoólicos das plantas Nasturtium officinale (agrião), Rosmarinus offinalis (alecrim), Tabebuia impetiginosa (ipê roxo), Achillea millefolium (mil folhas) e Plantago major (tanchagem), desenvolvido na Faculdade de Ciências Farmacêuticas/UNESP Araraquara. Foram selecionados 40 pacientes, jovens e adultos, entre 18 e 45 anos, usuários de aparelho ortodôntico corretivo (fixo), divididos em dois grupos, o grupo do Cepacol e o grupo do Enxaguatório base de plantas. Foram coletadas amostras nos períodos de 0, 7, 15 e 21 dias e analisadas observando-se as Unidades Formadoras de Colônia (UFC) de cada amostra. Houve uma queda significativa da quantidade de bactérias após o uso do Enxaguatório à base de plantas, revelando um produto de extrema utilidade no auxílio do controle do biofilme bacteriano nas superfícies dentárias. / In dentistry, there is a great concern with the formation of plaque or biofilm, due to its cariogenic potential. This attention extends to orthodontics due to the accumulation of biofilm on orthodontic appliances, removable appliances as much in the brackets. It is very common the presence of white spots after removal of the brackets, around 50 to 75% of patients, which are caused by biofilms. It takes a rigorous mechanical and chemical control in order to avoid irreversible changes in the teeth and periodontium. The mechanical control is by proper brushing, correct flossing and also the frequency of these habits, besides, of course, a periodical professional monitoring. Chemical control can be achieved by the use of mouthwashes, home to some undesirable effects and contraindications related to the use and age of patients. This study aimed to assess two mouthwashes, a commercial type (Cepacol ®) and other non-commercial, made with hydroalcoholic extracts of plants Nasturtium officinale (watercress), offinalis Rosmarinus (rosemary), Tabebuia impetiginosa ( purple ipe), Achillea millefolium (thousand leaves) and Plantago major (plantain), developed at the Faculty of Pharmaceutical Sciences / UNESP Araraquara. We selected 40 patients, young and adults between 18 and 45 years, users of orthodontic appliance (fixed), divided into two groups, the Cepacol group and the group of herbal mouthwash. Samples were collected during periods of 0, 7,15 and 21 days and analyzed by observing the Colony Forming Units (CFU) of each sample. There was a significant decrease in the amount of bacteria after using herbal mouthwash, revealing a product of the utmost use in aiding the control of bacterial biofilms on tooth surfaces.
34

Adesão bacteriana em braquetes metálicos com tratamento de superfície: estudo in vitro

Tupinambá, Rogerio Amaral [UNESP] 21 December 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-12-21Bitstream added on 2014-06-13T19:14:22Z : No. of bitstreams: 1 000734194.pdf: 8481046 bytes, checksum: 0d20d689a392b10b67c048f985b1dd09 (MD5) / A evolução dos acessórios utilizados em Ortodontia, especialmente no desenho e nos materiais empregados na confecção dos braquetes, tem apresentado grandes avanços tecnológicos. A presença dos aparelhos dentários aumenta a possibilidade de adesão bacteriana sobre estas superfícies e assim, o risco à cárie nos pacientes ortodônticos. Modificações na superfície dos braquetes, como o aumento da hidrofobicidade, redução da rugosidade superficial e deposição de filmes, tem sido empregadas como opção para redução da adesão bacteriana. Neste estudo in vitro, filmes de polímero de hexametildisiloxano foram depositados sobre braquetes metálicos convencionais e autoligantes, empregando a técnica PECVD (Deposição Química por Plasma de Rádio Frequência).As amostras foram divididas emquatrogrupos, dois com e dois sem tratamentode superfície. Foram avaliadas a variação da molhabilidade, rugosidade superficial e adesão de biofilme de Streptococos mutans.Os valores obtidos paraadesão de biofilmeforam analisados usando o teste de Kruskal-Wallis e SNK.Os resultados mostraram diferença estatística significante (p ≤0.05) entre os braquetes convencionais com e sem filme e, entre os braquetes convencionais e braquetes autoligantes. Portanto se conclui, que o tratamento de superfície foi efetivo na redução da adesão bacteriana nos braquetes convencionais, se observou também, que os braquetes convencionais apresentaram menor adesão de biofilme que os braquetes autoligantes / The evolution of the accessories in Orthodontics,especially in the design and materials used in the brackets manufacture, has exhibited major technological advances.The presence of dental appliances increases the possibility of bacterial adhesionon these surfaces and thus the risk of caries in orthodontic patients. Changes on the brackets surface, asthe increased hydrophobicity, reduced surface roughness and film deposition have been employed asan option for reducing bacterial adhesion. In this in vitro study, hexamethyldisiloxane polymer films were deposited on conventional and self-ligating stainless steel brackets, using the Radio Frequency PECVD technique (Plasma- Enhanced Chemical Vapor Deposition). The samples were divided into four groups according to the surface treatment, two treated and two untreated. The changes in wettability, surface roughness and adhesion of the Streptococcus mutans biofilm were evaluated. The values obtained for biofilm adhesion were analyzed using the Kruskal-Wallis and SNK test. The results showed statistically significant difference (p ≤ 0.05)between conventional brackets before and after surface treatment and between conventional and self-ligating brackets. Therefore it was concluded that surface treatment was effective in reducing bacterial adhesion inconventional brackets, it was also noted that the conventional brackets showed lower biofilm adhesion than self-ligating brackets
35

Estudo in vitro de braquetes ortodônticos: avaliação biomecânica e liberação de íons

Guimarães, Andréia Cecilia May [UNESP] 05 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-05Bitstream added on 2014-06-13T18:30:59Z : No. of bitstreams: 1 guimaraes_acm_me_guara.pdf: 1463910 bytes, checksum: 86d009497e85e3bccfe639908d568618 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Braquetes ortodônticos são feitos de diversos tipos de materiais, tais como, metais, cerâmicas e polímeros. Entre todos os materiais metálicos, o aço inoxidável é o mais empregado devido ao seu baixo custo associado a sua resistência à corrosão. No ambiente oral, eles estão sujeitos a fluídos agressivos e variações de pH, levando a liberação de íons nos tecidos e fluídos. Modificações na superfície destas ligas foram realizados utilizando tratamentos mecânicos, eletroquímicos, químicos e físicos. O carbono amorfo hidrogenado (a-C: H) preparado para técnicas de deposição apresentam muitas propriedades atraentes como alta dureza, serem químicamente inertes e biocompatíveis. Neste estudo in vitro, filmes de a-C:H foram depositados em braquetes ortodônticos pela técnica de deposição química por plasma de radiofreqüência (PECVD) e inibiu a liberação de íons níquel. Após o tratamento de superfície, os braquetes foram colados em incisivos bovinos com uma resina composta e as amostras foram imersas em soro fisiológico por 30 dias à 37 º C. Durante o tempo de imersão as amostras foram lavadas e imersas em flúor diariamente. Antes da imersão, o arranjo estrutural dos filmes foi analisado por espectroscopia de Raman e medidas do ângulo de contato foram realizadas, a fim de avaliar a molhabilidade da superfície. Espectrometria de absorção atômica foi usada para medir a liberação de elementos a partir de amostras e a análise superficial foi realizada em microscópio eletrônico de varredura (MEV). Os resultados mostraram que o revestimento previne a liberação de Ni dos braquetes nos testes estatísticos e o níquel foi liberado de outros grupos sem tratamento de superfície . A análise de variância não indicou diferença significativa entre os grupos depois do ensaio de cisalhamento. / Orthodontics brackets have been made from a variety of materials such as metals, ceramics and polymers. Among all the metallic materials, stainless steel are the most popular due low cost associated with reasonable corrosion resistance. In oral environment, they are subject aggressive fluids and pH variation can be leave nickel ions release to body tissues and fluids. Surface modifications of these alloys have been realized using mechanical, electrochemical, chemical and physical treatments. Hydrogenated amorphous carbon (a-C:H) prepared by deposition techniques have very attractive properties such as high hardness, chemical inertness and biocompatibility. In this in vitro study, a-C:H films were deposited on orthodontics brackets by r.f. plasmaenhanced chemical vapour deposition (PECVD) from inhibited nickel ions release. After treatment, brackets were bonded to bovine incisors with a composite resin and samples were immersed in physiological serum for 30 days at 37 ºC. During immersion time samples were brushed and/or immersed in mouthwashes daily. Prior immersion, the structural arrangement of films was probed by Raman spectroscopy and contact angle measurements were carried out in order to evaluate the wettability of surface. Atomic absorption spectrophotometry was used to measure the release of elements from the samples and SEM for surface analysis. Results showed that the coating prevents Ni release of brackets for statistic test and nickel was released for others groups. Analysis of variance no indicated significance different among groups after shear testing.
36

Roller Braquete: an?lise de um novo modelo de braquete que permite a diminui??o do dtrito em compara??o com o braquete convencional ? estudo realizado via m?todo de elemento finito / Roller Bracket: an analisys new bracket model that allows the reduction of friction when compared to the conventional bracket - study via finite element method

Fonseca, Cynthia Couto Pimenta January 2015 (has links)
?rea de concentra??o em Odontopediatria. / Submitted by Alexandre Soares (alexandredesoares@yahoo.com.br) on 2016-07-14T20:41:52Z No. of bitstreams: 1 cynthia_couto_pimenta.pdf: 1533777 bytes, checksum: 203f6a9fcdbba7c6f71ded6949262115 (MD5) / Rejected by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br), reason: Os titulos devem estar em caixa baixa. Ex. Os casos de .... on 2016-07-15T20:03:55Z (GMT) / Submitted by Alexandre Soares (alexandredesoares@yahoo.com.br) on 2016-07-15T20:11:02Z No. of bitstreams: 1 cynthia_couto_pimenta.pdf: 1533777 bytes, checksum: 203f6a9fcdbba7c6f71ded6949262115 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2016-07-18T14:37:09Z (GMT) No. of bitstreams: 1 cynthia_couto_pimenta.pdf: 1533777 bytes, checksum: 203f6a9fcdbba7c6f71ded6949262115 (MD5) / Made available in DSpace on 2016-07-18T14:37:09Z (GMT). No. of bitstreams: 1 cynthia_couto_pimenta.pdf: 1533777 bytes, checksum: 203f6a9fcdbba7c6f71ded6949262115 (MD5) Previous issue date: 2015 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico (CNPq) / Funda??o de Amparo ? Pesquisa do Estado de Minas Gerais (FAPEMIG) / Objetivos: Apresentar um novo modelo de braquete, denominado Roller Braquete, como alternativa para reduzir o atrito na pr?tica cl?nica ortod?ntica, e avaliar o atrito na base do Roller Braquete comparando com o braquete convencional, por meio do m?todo de elementos finitos (MEF). M?todos: O Roller Braquete foi desenvolvido e patenteado pelo prof. Leandro Silva Marques e considera especificamente a incorpora??o de esferas deslizantes (flutuantes) no fundo canaleta do braquete. Modelos bidimensionais constru?dos pelo m?todo de elementos finitos foram utilizados para desenvolver an?lises do problema via simula??o computacional. A geometria dos corpos analisados foi desenvolvida em software de Computer Assisted Design (CAD). O modelo de elementos finitos foi gerado por meio de um software Computer Assisted Engineering (CAE). Para a obten??o de um modelo te?rico por meio do MEF, as caracter?sticas geom?tricas e propriedades dos materiais utilizados no Roller Braquete foram definidas previamente, de acordo com estudos relatados na literatura cient?fica. A morfologia deste braquete foi baseada em braquetes convencionais dispon?veis no mercado. A estrutura criada foi discretizada em elementos finitos, utilizando-se o software Abaqus? (Dessault Syst?mes, Fran?a). Resultados: As esferas flutuantes localizadas na base do Roller Braquete favorecem a redu??o da dissipa??o de energia, diminuindo o atrito. O Roller Braquete apresenta caracter?sticas estruturais e propriedades mec?nicas que representam avan?os quando comparadas aos braquetes convencionais. A redu??o da dissipa??o de energia ? maior no Roller Braquete quando comparada com o braquete convencional. Considerando a presen?a de um lubrificante, a redu??o da for?a de atrito no Roller Braquete chega a 48% em compara??o ao braquete convencional. Conclus?o: A principal vantagem que o Roller Braquete acrescenta em rela??o ao estado da t?cnica, se fundamenta em ser um acess?rio que pode ser utilizado como alternativa para diminuir o atrito quando comparado ao braquete convencional, diminuindo os efeitos prejudiciais ? biomec?nica do tratamento ortod?ntico / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Odontologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2015. / ABSTRACTObjectives: To present a new bracket model, denominated Roller Bracket, as an alternative to reduce friction in orthodontic clinical practice, and evaluate the friction at the base of Roller Bracket compared with the conventional bracket, through the finite element method (FEM). Methods: The Roller Bracket was developed and patented by Prof. Leandro Silva Marques and considers specifically the incorporation of sliding beads (floating) on the bottom of the slot of the bracket. Two-dimensional models constructed by the finite element method were used to develop analysis of the problem via computer simulation. The geometry of analyzed bodies was developed in Computer Assisted Design (CAD). The finite element net where the boundary conditions were imposed was generated by software Computer Assisted Engineering (CAE). To obtain a theoretical model by means of the FEM, the geometric characteristics and material properties used in the Roller Bracket were previously defined. The morphology of this bracket was based on conventional brackets available elsewhere. The structure was discretized into finite elements, using the Abaqus software (Dassault Syst?mes, France). Results: The floating spheres situated at the base of Roller bracket promote the reduction of power dissipation, reducing friction. The Roller Bracket has structural characteristics and mechanical properties that represent improvements when compared with conventional brackets. The reduction of power dissipation is higher in the Roller Bracket when compared with the conventional bracket. Considering the presence of a lubricant, the reduction of friction force in Roller Bracket reaches 48% when compared with conventional brackets. Conclusion: The roller Bracket adds several advantages over the state of art, being an accessory that can be used as alternative to reduce the friction when compared with conventional brackets, reducing the impairing effects on the biomechanics of the orthodontic treatment.
37

Resistência ao cisalhamento de brackets ortodônticos com diferentes tratamentos de superfície e cerâmicas

May, Naudy Brodbeck January 2005 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-07-16T01:37:40Z (GMT). No. of bitstreams: 1 225721.pdf: 8647127 bytes, checksum: ec8fd37c2ae3b18659c05c993a86a03a (MD5) / Este estudo avaliou a resistência ao cisalhamento da união bracket/cerâmica, após diferentes pré-tratamentos da superfície cerâmica. Foram selecionadas duas cerâmicas (Eris e d.Sign) e os materiais (óxido de alumínio, CoJet, agente silano, concise, ácido fluorídrico a 10%, ácido fosfórico a 35%). Pôde-se concluir que: 1) as duas cerâmicas desempenharam papel similar; 2) a utilização do silano após condicionamento com ácido fluorídrico foi responsável pelo aumento nos valores de união; 3) o pré-tratamento por meio do condicionamento com ácido fluorídrico a 10% por 20s e utilização de agente silano, bem como o jateamento com óxido de alumínio (50 m) por 15s,seguido do condicionamento com ácido fosfórico a 35% e aplicação do agente silano, promoveram os mais altos valores de resistência da união; 4) a utilização do sistema CoJet não resultou em valores estatisticamente superiores aos observados no tratamento com óxido de alumínio, igualando-se aos grupos tratados com ácido fluorídrico sem aplicação de silano; 5) o jateamento com óxido de alumínio, seguido do condicionamento com ácido fosfórico e silano apresentou resultados semelhantes ao tratamento com ácido fluorídrico e silano.
38

Resistência adesiva ao cisalhamento de brackets cerâmicos monocristalinos : estudo in vitro / Luís Filipe Siu Lon ; orientador, Olilon Guariza Filho

Lon, Luís Filipe Siu January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Bibliografia: f. 35-38 / Introdução: A crescente procura por tratamentos ortodônticos pelos adultos em busca de correção da oclusão e estética, tem aumentado a demanda no uso de rackets cerâmicos. O objetivo deste trabalho foi avaliar, in vitro, a Resistência Adesiva (RA) ao cisa / Abstract: The purpose of this study was to evaluate the Shear Bond Strength (SBS) and the adhesive failure mode of Radiance® (American Orthodontics, Sheboygan, Wisc) and Inspire Ice® (ORMCO, Orange, Calif) monocrystalline ceramic brackets and compare them
39

O efeito de brackets cerâmicos e ligaduras metálicas ou elástica na mucosa bucal : avaliação citológica = The effect of ceramic brackets and metal or elastic ligatures on the oral mucosa : cytologic evaluation / Mariana Bridi Moschetti ; orientadora, Elisa Souza Camargo ; co-orientador, Antônio Adilson Soares de Lima

Moschetti, Mariana Bridi January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Inclui bibliografias / INTRODUÇÃO: O aparelho ortodôntico fixo pode produzir ulcerações, abrasão de tecidos moles e desconforto. Objetivou-se analisar as células epiteliais da mucosa bucal adjacente ao aparelho ortodôntico fixo com diferentes tipos de ligaduras. MÉTODOS: Foram / BACKGROUND: The fixed orthodontic appliance can produce ulcerations, soft tissue abrasion and discomfort. The purpose of this study was to analyze the epithelial cells of the oral mucosa adjacent to the fixed orthodontic appliance using different types of
40

Rugosidade natural do esmalte e sua influência na resistência adesiva = Natural enamel roughness and its influence on bond strength / Marcos Adriano Sabatoski ; orientador, Hiroshi Maruo / Natural enamel roughness and its influence on bond strength

Sabatoski, Marcos Adriano January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Inclui bibliografias / Introdução: O objetivo deste trabalho foi determinar e comparar os parâmetros da rugosidade longitudinal e transversal da superfície do esmalte de dentes bovinos e, avaliar a influência desses parâmetros na resistência adesiva (RA). Métodos: Foram utiliza / Introduction: The aim of this study was to determine and compare the longitudinal and transversal roughness parameters of the enamel surface of bovine teeth and evaluate the influence of these parameters on bond strength (BS). Methods: Ninety bovine incis

Page generated in 0.0477 seconds