• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 73
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 6
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 75
  • 62
  • 42
  • 35
  • 29
  • 28
  • 21
  • 20
  • 20
  • 19
  • 18
  • 17
  • 15
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

ANÁLISE COMPARATIVA DOS NÍVEIS DE ATRITO EM BRÁQUETES CONVENCIONAIS E AUTOLIGADOS / Friction levels comparative analysis in self-ligated and conventional brackets.

Picchioni, Mauro dos Santos 06 March 2007 (has links)
Made available in DSpace on 2016-08-03T16:31:07Z (GMT). No. of bitstreams: 1 Mauro dos Santos Pichioni.pdf: 2125883 bytes, checksum: cef06952dac67f4c03556888123fea6b (MD5) Previous issue date: 2007-03-06 / The friction between brackets and orthodontic wires is an important issue to be considered concerning to orthodontic treatment efficiency in the sliding mechanics. Because this, always there are a search for ways to reduce the friction levels during this type of mechanics. With the introduction of self-ligated bracketts, it was observed that one of these devices main characteristics would be a reduction levels reduction of friction between brackets and wires, and because this the movement could be more efficient, with the application of low forces when compared the using of brackets with conventional ligation systems. The purpose of this study is compare by means of laboratorial tests, the esthatic friction coefficients of one esthetic self-ligated bracket, one metallic self-ligated bracket and two metallic conventional brackets, with the orthodontic wires of different materials, section and sizes, to determine which brackets presents the lowest coefficients of friction, in situations of different angulations between wires and brackets. The results had demonstrated that self-ligated brackets had presented a static friction significantly lower at situations whitout angulation between the wire and brackets and when using small size wires, with more flexible material, when compared with conventional brackets. The metallic self-ligated bracket presented more friction, similar the conventional brackets, with the use larger diameter wires, without angulation between bracket and wire. The metallic self-ligated bracket presented higher static friction when compared with conventional brackets, with the use larger diameter wires, at situations with angulation betwen bracket and wire. / O atrito existente entre bráquetes e os fios ortodônticos é um fator importante a ser considerado quanto à eficiência do tratamento ortodôntico nas mecânicas de deslize. Em função disto, sempre se procurou maneiras de se diminuir os níveis de atrito durante a aplicação deste tipo de mecânica. Com o surgimento dos bráquetes autoligados, observou-se que uma das características principais destes dispositivos seria uma redução dos níveis de atrito entre os bráquetes e fios, e com isso poderia se obter um movimento de deslizamento eficiente com a aplicação de forças menores, quando comparado com o uso de bráquetes que tenham sistemas de amarração convencionais. O propósito deste trabalho foi comparar, por meio de ensaios laboratoriais, os níveis de atrito estático de um bráquete autoligado estético, de um bráquete autoligado metálico e dois tipos de bráquetes convencionais metálicos, com a utilização de fios ortodônticos de diferentes ligas, secção e diâmetros, para determinar quais bráquetes apresentam os menores coeficientes de atrito, em situações sem angulação, em angulações de primeira ordem e angulações de segunda ordem entre os diferentes fios e bráquetes. Os resultados demonstraram que os bráquetes autoligados apresentaram um atrito estático significativamente mais baixo nas situações onde não existiu angulação entre o fio e o bráquete e quando se utilizou fios de calibres menores e com material mais flexível, quando comparados com os bráquetes convencionais. O bráquete autoligado metálico apresentou maior atrito, semelhante aos bráquetes convencionais, com o uso dos fios de maior calibre, nas situações sem angulação. O bráquete autoligado metálico apresentou maior atrito estático que os bráquetes convencionais, nas situações de angulação, com o uso dos fios de maior calibre
42

ESTUDO COMPARATIVO DAS ANGULAÇÕES E TORQUES DE BRAQUETES DE DIFERENTES MARCAS COMERCIAIS / Comparative study of angulation and inclination of different brackets trademarks

Zanesco, Alexandre 27 April 2008 (has links)
Made available in DSpace on 2016-08-03T16:31:12Z (GMT). No. of bitstreams: 1 Alexandre Zanesco.pdf: 1035848 bytes, checksum: d02024f61764f0328225b9a073241130 (MD5) Previous issue date: 2008-04-27 / The purpose of this study was to compare the angulations and torques of orthodontic brackets from different trademarks in relation to the Roth s prescription and also in relation with the recommended values from the manufacturer. It was used 150 orthodontic metalic stainless steel brackets, from upper cuspid and incisors in its prescription and evaluated through a vertical Benchtop Measuring Projector in the Metrology laboratory of Dental Morelli Ltda. After collecting the results and the application of statistical test, it was obtained that values of torque found with the Roth´s prescription was similar between the manufacturer and the cuspid angulation has been shown higher values in comparison to that proposed from the author in the manufacturer Morelli, and for the teeth 2.1 and 2.2, the increased angulation was showed on Abzil manufacturer s bracket. On comparative values of torque obtained within all manufacturers, Unitek showed greater reliability in torque values than others. For angulation, the reliability of the same manufacture was not superious when compared to the other manufacturers. It was concluded that the differences on both torque and angulation to the author values and prescription of the manufacturers studies fall within the degree of advocated tolerance by a German association of orthodontic accessories. / O objetivo deste estudo foi comparar as angulações e torques de braquetes de marcas comerciais distintas em relação à prescrição de Roth e também em relação aos valores preconizados pelo fabricante. Foram utilizados 150 braquetes metálicos de aço inoxidável, de caninos e incisivos superiores na respectiva prescrição, avaliadas por meio de um perfilômetro. Após a coleta dos dados e aplicação do tratamento estatístico, os resultados demonstraram que os valores de torque obtidos com a prescrição de Roth foram semelhantes entre os fabricantes. Na angulação, os caninos superiores apresentaram valores acima do proposto pelo autor para o fabricante Morelli, e para os dentes 21 e 22, a angulação foi maior para o fabricante Abzil. Na comparação dos valores de torque obtidos com os valores recomendados pelos fabricantes, a Unitek demonstrou maior fidedignidade no torque comparada às demais marcas. Conclui-se que as diferenças tanto de torque quanto de angulação quando comparados aos valores do autor e à prescrição dos fabricantes, se enquadram dentro de um grau de tolerância preconizada por um órgão regulador de peças ortodônticas alemãs.
43

AVALIAÇÃO IN VITRO DA RESISTÊNCIA DA COLAGEM DE BRAQUETES LINGUAIS COM DIFERENTES ESPESSURAS DE RESINA / In vitro shear bond strenght evaluation of lingual brackets bonding with different resin thicknesses.

Wunderlich Junior, Afonso Eugênio 30 March 2009 (has links)
Made available in DSpace on 2016-08-03T16:31:12Z (GMT). No. of bitstreams: 1 Afonso Eugenio.pdf: 3225000 bytes, checksum: 3ec57b1525dae6e079bc14c912078ed8 (MD5) Previous issue date: 2009-03-30 / This study evaluated lingual brackets bonding on the lingual surfaces of bicuspids with different PAD thickness, made with Transbond XT light cured resin in 1.00 m and 2.00 mm thicknesses and compared to the lowest possible thickness. The Sondhi Rapid-Set bonding adhesive was used for indirect bonding. Shear bond strength was evaluated five minutes after bonding, using a Kratos universal testing machine, with a crosshead speed of 1.0 mm/min. The mean force of shear bond strength for Group I was 9.69 MPa (SD 4.02 MPa); 6.15 MPa (SD 2.69 MPa) for Group II; and 5.73 MPa (SD 1.62 MPa) for Group III. Group I, with lower PAD thickness, featured significantly greater shear bond strength than Groups II and III (PADs equal to 1.0 mm and 2.0 mm, respectively). The latter two groups showed no significant difference at p<0.05. Score 1 of the Adhesive Remnant Index prevailed in Groups I and II, characterizing a greater number of adhesive fractures. In Group III, score 2 prevailed, with cohesive-type fractures.(AU) / Este estudo avaliou a colagem de braquetes linguais nas faces linguais de pré-molares superiores com diferentes espessuras de PADs, confeccionados com a resina fotopolimerizável Transbond XT nas espessuras de 1,0 mm e 2,0 mm e comparando-os com a menor espessura possível. Foi utilizado o adesivo Sondhi Rapid Set para a colagem indireta. Avaliou-se a força de resistência sob cisalhamento cinco minutos após a colagem em uma máquina de ensaios mecânicos Kratos, com velocidade de cruzeta de 1,0 mm/min. A força média da resistência da colagem sob cisalhamento para o Grupo I foi de 9,69 MPa (DP 4,02 MPa), para o Grupo II foi de 6,15 MPa (DP 2,69 MPa) e para o Grupo III foi de 5,73 MPa (DP 1,62 MPa). O Grupo I, com menor espessura do PAD, apresentou força de resistência da colagem sob cisalhamento significativamente maior do que os Grupos II e III (PADs com 1,0 e 2,0 mm respectivamente). Estes por sua vez, não apresentaram diferença estatisticamente significante ao nível de p<0,05. O índice 1 de Adesivo Remanescente predominou nos Grupos I e II, caracterizando um maior número de fraturas do tipo adesiva. No Grupo 3 predominou o Índice 2, com fraturas do tipo coesiva.(AU)
44

COMPARAÇÃO DO ATRITO IN VITRO EM BRAQUETES ESTÉTICOS CONVENCIONAIS E AUTOLIGADOS / A comparison of in vitro friction forces among conventional and self-ligating aesthetic orthodontic brackets

Leal, Rodrigo Severo 25 March 2009 (has links)
Made available in DSpace on 2016-08-03T16:31:14Z (GMT). No. of bitstreams: 1 Paginas 1 a 110.pdf: 2675655 bytes, checksum: ebe1b48d56fd661d5dc8a8a84083c9f1 (MD5) Previous issue date: 2009-03-25 / The aim of this in vitro study was to compare the friction resistances among conventional steel-ligated and self-ligating aesthetic brackets with different retangular stainless steel archwires sizes at zero and three degrees angulation. 120 brackets of 6 commercial brands (Gemini, Clarity conventional, Transcend, Inspire, Clarity self-ligating, Damon self-ligating) where tested, 20 brackets of each brand. Two brackets were glued on a metallic plate, with angulations of zero and three degrees between them. Retangular stainless steel archwires of 0.017 x 0.025 , 0.019 x 0.025 and 0.021 x 0.025 were tested on a "instron" universal essay machine. Variance analisys and Tukey tests (p<0,05) were run to compare brackets with different archwires sizes and angulation. The study demonstrated that at zero degree angulation the self-ligating brackets produced less friction in relation to convencional ligated bracket in all archwires sizes tested. Clarity self-ligating produces even less friction then aesthetic Damon, except with the 0.021 x 0.025 archwire, where both self-ligating brackets produced statisticly similar results. Inspire bracket had the least friction with 0.019 x0.025 and 0.021 x0.025 . Similar results were observed for the self-ligating brackets in relation to convencionals at three degrees angulation. Among the convencional steel-ligated brackets, Gemini, Clarity, Transcend and Inspire produced the higest friction resistances, in increasing order. In conclusion, the angulation between the brackets increases significatively the friction forces. Furthermore, the self-ligating brackets produces less friction in relation to conventional ligating brackets, and the Clarity self-ligating bracket produced less friction than aesthetic Damon, except with 0.021 x 0.025 archwire size.(AU) / O objetivo do presente estudo consistiu em comparar in vitro o atrito produzido por braquetes estéticos, convencionais e autoligados quando inseridos fios retangulares de aço inoxidável de diferentes dimensões, nas angulações de zero e três graus entre os braquetes. Foram utilizados 120 braquetes de 6 marcas comerciais (Gemini, Clarity convencional, Transcend, Inspire, Clarity autoligado, Damon autoligado), sendo 20 braquetes de cada marca comercial. Para os ensaios laboratoriais, foram colados dois pares de braquetes de cada marca comercial em uma placa metálica, com uma angulação de zero e três graus entre os braquetes. Foram empregados os fios retangulares de aço inoxidável 0,017 x 0,025 , 0,019 x 0,025 e 0,021 x0,025 em uma máquina de ensaios universal Instron . Para a comparação entre os braquetes nos diferentes fios e angulações, foi utilizada a análise de variância e o teste de Tukey (p<0,05). Os resultados demonstraram que na angulação de zero grau, os braquetes autoligados apresentaram menor atrito em relação aos convencionais em todos os fios avaliados, sendo que, o braquete Clarity autoligado apresentou menor atrito estatisticamente significante que o Damon, exceto no fio 0,021 x 0,025 , em que ambos os braquetes autoligados apresentaram atrito estatisticamente semelhante. O braquete Inspire demonstrou o maior atrito em relação aos demais braquetes nos fios 0,019 x0,025 e 0,021 x0,025 . Na angulação de três graus, observou-se resultados semelhantes aos braquetes posicionados sem angulação comparando os braquetes autoligados em relação aos convencionais. Contudo, verificou-se que o atrito entre os braquetes convencionais ocorreu em ordem crescente sendo braquetes Gemini, Clarity convencional, Transcend e Inspire. Pôde-se concluir que a angulação entre os braquetes aumenta consideravelmente o atrito. Além disso, em ambas as angulações, os braquetes autoligados demonstraram menor atrito em relação aos convencionais, sendo que o braquete Clarity autoligado promoveu menor atrito que o Damon estético, exceto no fio 0,021 x 0,025 .(AU)
45

Estudo comparativo in vivo e in vitro da resistência ao cisalhamento de braquetes metálicos colador com resina polimerizada com luz halógena e LEd

Penido, Sérgio Milton Martins de Oliveira [UNESP] 30 May 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-05-30Bitstream added on 2014-06-13T19:44:08Z : No. of bitstreams: 1 penido_smmo_dr_arafo.pdf: 996491 bytes, checksum: 142106818d9d76c3991a99fe95fe589a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho teve como objetivo avaliar a resistência ao cisalhamento, in vivo e in vitro, de braquetes metálicos (Abzil Lancer) colados em dentes humanos com material adesivo polimerizado xom luz halógena e LED. Os braquetes foram cotados em 60 pré-molares formando seis grupos. Nos Grupos I e II os braquetes foram colados nos segundos pré-molares respectivamente no lado direito e esquerdo dos pacientes. A polimerização do material adesivo foi com a luz de LED epara o GI e luz halógena para o GII. Nos demais grupos os braquetes foram colados em primeiros pré-molaressuperiores e inferiores extraídos por motivos ortodônticos. A polimerização realizada nos grupos III e V foi com o aparelho de LED enquanto que nos grupos III e V foi com o aparelho de LED enquanto que nos grupos IV e VI com luz halógena. Nos Grupos I e II testes de cisalhamento foram realizados utilizando-se dinamômetro sigital portátil diretamente na boca dos pacientes. Os grupos IIII, IV, V e VI foram armazenados em água destilada e levados a estufa a 37ºC por 24 horas e posteriormente, submetidos a termociclagem, com 1000 ciclos a 5 e 55ºC. Posteriormente, nos grupos III e IV, utilizou-se máquina universal de ensaios mecânicos e nos grupos IV e VI os ensaios mecânicos foram realizados com dinamômetro digital. Os valores médios da resistência ao cisalhamento em Mpa foram de: GI = 3,65; GII = 4,39; GIII = 6,45; GIV = 7,11; GV = 4,67; GVI = 4,21. Após a descolagem foram realizadas fotografias Das áreas de colagem. As imagens obtidas foram ampliadas %x, analisadas e classificadas de acorso com o índice de Adesivo Remanescente (IAR). Os resultados dos testes mecânicos in vivo ou in vitro. Os testes realizados com equipamento portátil digital tiveram valores médios significativamente menores em relação áqueles realizados em máquina de ensaios mecânicos universal. Não houve relação definida entre carga de ruptura e tipo de falha. / This work as a purpose to assess the shear bond strength, in vivo and in vitro , of metallic brackets (Abzil lancer) bondedto human teeth with light-curing bonding material with halogen and led lights. The brackets were bonded to 60 premolars, so forming 6 groups.In GI and II the brackets were bonded to second premolars, resectively, on the right and left sides of the patients. The polymerization of the bonding material was with LED light for GI and halogen light for GII. In the other groups the brackets were bonded to superior and inferior first premolars, extrated for orthodontic reasons. The polymerizatio was performed in GII and V with LED device, while in GIV and VI eith halogen light. In GI and II shear strength tests were made using a portable digital dynamoter directly in the patients' mouths. GII, IV, V and VI were stored in distilled water and taken to sterilizer at 37ºC for 24 hours, and afterwards, submitted to thermocycling with 1000 cycles at 5 and 55 º. Then, in GIII and IV, the Universal testing machine was used and in GIV and VI the mechanical tests were performed with a digital dynamometer. The average values of shear strength in Mpa were: GI=3,65; GII=4,39; GIII=6,45; GIV=7,11; GV=4,67 and GVI=4,21. Pictures of thebonding areas were taken after the tests. The images obtained amplified 5 times, analyzed and classified, according to Adhesive remaining index (IAR). The results suggested that the LED light or the halogen light did not interfere in the results of the mechanical tests in vivo or in vitro. The tests performed with a portable digital device obtained average values significantly lower than those performed with Universal testing machine. There was no definite relation between shear bond strengths and kind of failure.
46

Avaliação de protocolos para colagem de bráquetes cerâmicos e remoção do adesivo remanescente com vistas á preservação da integridade de esmalte dentário

Vianna, Alexandre Protásio [UNESP] 08 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-08Bitstream added on 2014-06-13T19:07:08Z : No. of bitstreams: 1 vianna_ap_dr_arafo.pdf: 843063 bytes, checksum: 4531dd78f0e6348ef44fc614df388067 (MD5) / Introdução: Este estudo teve como objetivos: Avaliar a influência de diferentes protocolos de condicionamento do esmalte e de cura luminosa dos sistemas adesivos testados, na resistência da colagem de bráquetes de cerâmica ao cisalhamento; na ocorrência de fraturas de esmalte e na quantidade de adesivo remanescente. Além disso, o Método dos Elementos Finitos foi empregado para analisar como os esforços relativos à descolagem atuaram na superfície do esmalte. Com auxílio da Microscopia eletrônica de varredura, avaliou-se a ação de 05 métodos para remoção da camada de adesivo remanescente quanto às alterações geradas nas características superficiais originais do esmalte e quanto ao tempo de execução dos procedimentos. Material de Método: 40 bráquetes Inspire IceTM, 40 bráquetes ClarityTM e 40 bráquetes GeminiTM foram aleatoriamente colados a 120 pré-molares com faces vestibulares hígidas, seguindo diferentes protocolos de condicionamento do esmalte e de fotopolimerização. Essas colagens foram testadas em ensaio mecânico por cisalhamento e também analisadas pelo método dos elementos finitos. Além disso, 25 molares permanentes com faces vestibulares hígidas passaram pela remoção de camadas padronizadas de adesivo remanescente com 05 métodos diferentes. As superfícies iniciais e finais de cada dente foram avaliadas por meio da microscopia eletrônica de varredura. O tempo gasto na execução de cada procedimento foi também avaliado. Resultados: As colagens com o TPSEP apresentaram menores valores de resistência da colagem ao cisalhamento e não estiveram associadas a fraturas de esmalte. Houve coincidência entre o modo de descolagem dos braquetes e a distribuição dos esforços na superfície do modelo 3D. As menores alterações à superfície do esmalte foram geradas... / Introduction: The aims of this study were to evaluate the influence of different protocols for enamel acidic etching and for light-curing of the adhesive systems tested about: shear bond strength of ceramic brackets; occurrence of enamel fractures and adhesive remnant index. Finite element method was also used to identify how debonding efforts act on enamel surface. Scanning Electron Microscopy was applied to assess the changes observed on original enamel surface characteristics generated by 05 methods for residual adhesive removal. The chair time related to the 05 methods under study was also evaluated. Material and Methods: 40 Inspire Ice Brackets; 40 Clarity Brackets and 40 metal Brackets (Gemini) were randomly bonded to 120 bicuspides, using different protocols of enamel conditioning and photo-activation. 25 permanent molars were submitted to the removal of standardized adhesive layers, using 05 different methods. Initial and final surfaces were comparatively evaluated by scanning electron microscopy. The procedures chair times were also assessed. Results: Transbond Plus Self-etching Primer promoted bracket bonding with lower shear bond strengths and debonding procedures without enamel fractures. FEM analysis showed coincidence among efforts distribution simulated over the tridimensional model surfaces and the real debonding damages caused on enamel. The multi-blade carbide bur in low hand-piece speed caused lower alterations over enamel original surface. Conclusion: TPSEP seemed to be the adequate method for bracket bonding; metallic bracket bonding showed lower shear bond strength without primer light-curing but it was not true for the ceramic brackets; chair time of the procedure and the final aspect of enamel surface demonstrated... (Complete abstract click electronic access below)
47

Avaliação in vitro da fotopolimerização de bráquetes vestibulares e linguais com arco de plasma, led e luz halógena

Magno, Amanda Fahning [UNESP] 29 May 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-05-29Bitstream added on 2014-06-13T18:56:44Z : No. of bitstreams: 1 magno_aff_me_arafo.pdf: 677357 bytes, checksum: eeda74e2c1742441d13f507c4660bb18 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo dessa pesquisa foi avaliar in vitro a fotopolimerização de bráquetes vestibulares e linguais utilizando o arco de plasma, o diodo emissor de luz (LED) e a luz halógena convencional em tempos diferentes. Dois artigos científicos foram redigidos e utilizados para a avaliação dos propósitos apresentados. Na análise por vestibular, não houve diferenças entre o uso da luz arco de plasma por 6 segundos, do LED por 10 segundos e da luz halógena por 40 segundos. A luz arco de plasma por 3 segundos e o LED por 5 segundos demonstraram resistências ao cisalhamento iguais entre si e significantemente menores em relação às da luz halógena (p<0,001). Os resultados do índice de adesivo remanescente (IAR) mostraram que a interface de fratura dente/bráquete ocorreu com maior freqüência em todos os grupos, entretanto, os dados não puderam ser avaliados estatisticamente em função da distribuição dos escores. Na análise por lingual, as três fontes de luz mostraram-se diferentes entre si (p<0,001). A luz arco de plasma em 6 segundos obteve a menor média de resistência ao cisalhamento, seguida do LED em 10 segundos, que por sua vez apresentou menor média em relação à luz halógena em 40 segundos. O teste quiquadrado demonstrou não haver diferença significativa nos escores do IAR quando empregados os diferentes tipos de luz. Foi concluído, por vestibular, que a luz arco de plasma e o LED podem ser utilizados por tempos reduzidos em relação à luz halógena, sem perda de resistência ao cisalhamento, mas com limites para esta redução. Nos testes por lingual, a luz arco de plasma obteve resistências menores que o LED, o qual demonstrou resistências menores que a luz halógena, porém, estas diferenças não afetaram o padrão de descolagem. / The objective of this in vitro study was to evaluate the variation of temperature and Knoop microhardness on enamel surface during the bleaching process whith 35% hydrogen peroxide under irradiation by halogen light whit the wavelength of 400 to 500nm (HL), LED whit the wavelength of 460 to 480nm and high intensity diode laser LED whit the wavelength of 810nm (LD) on extracted human teeth. Initially were investigated the variation of surface temperature (infrared thermography) and the temperature of the interior of the pulp chamber (thermocouples) in human mandibular incisors when subjected to dental bleaching with 35% hydrogen peroxide in the colors red (HP) and green(HPM) irradiated by: HL and LED. Four groups (n = 10) were divided according to the bleaching gel and light source. The results were submitted to the analysis of variance and Tukey test (p < 0.05). The mean values and standard deviations of the temperature increase inside the chamber pulp with HL were 4.4 ± 2.1 °C using HP and 4.5 ± 1.2 °C using HPM; while in LED groups, were 1.4 ± 0.3 °C to HP, and 1.5 ± 0.2 °C using HPM. For all surface temperatures, the maximum variation of the groups irradiated with HL was 6.5 ± 1.5 °C to HP and 7.5 ± 1.1 °C using HPM; while for the groups using LED, were 2.8° ± 0.7 °C using HP, and 3 ± 0.8 °C for HPM. There were no statistical difference between the increase of pulp and superficial temperature between groups using the various gels (p < 0.05). Mean temperatures were significantly higher for groups using HL compared with those irradiated with LED (p < 0.05). Was investigated the variation of surface temperature and thus given the time-delay to hit the critical variation of temperature (5.5 °C for the pulp chamber and 10 °C for periodontal). Forty-five human inferior incisors were divided into 3 groups and submitted to dental bleaching using HP and activated by HL,...(Complete abstract, click electronic access below)
48

Análise in vitro da estabilidade de cor e rugosidade superficial de braquetes ortodônticos cerâmicos

Oliveira, Cibele Braga de [UNESP] 06 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-06Bitstream added on 2014-06-13T20:57:09Z : No. of bitstreams: 1 oliveira_cb_me_arafo.pdf: 821709 bytes, checksum: 552c0a23690dada1cca43d4d6e5259d1 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo objetivou analisar, in vitro, a estabilidade de cor e rugosidade superficial de braquetes cerâmicos após imersão em soluções corantes. Sete braquetes cerâmicos de incisivo central superior direito de quatro marcas comerciais foram testados: dois monocristalinos e dois policristalinos. Os braquetes foram imersos em quatro soluções corantes (café, vinho tinto, Coca-Cola e chá preto) e em saliva artificial separadamente nos seguintes tempos: T0 (mensuração inicial), T1, T2, T3 e T4 (24 horas, 7,14 e 21 dias respectivamente).Outros sete braquetes de cada marca comercial foram imersos nas mesmas soluções e em tempos iguais aos anteriores, porém com intervalos de escovação diários. As alterações de cor foram avaliadas por espectrofotômetro de reflectância e a rugosidade superficial por meio de um Rugosímetro. Os dados foram avaliados pela Análise de Perfis Multivariados, Análise de Variância (ANOVA), teste de comparação múltipla de médias e Teste t de Student. Com base nos resultados, houve alteração perceptível de cor em todos os braquetes cerâmicos após 21 dias de imersão nas soluções de café (ΔE do Allure = 7,61, Inspire Ice = 6,09, Radiance=6,69, Transcend=7,44), chá preto (ΔE do Allure = 6,24, Inspire Ice = 5,21, Radiance=6,51, Transcend=6,14) e vinho tinto (ΔE do Allure =6,49 , Inspire Ice = 4,76, Radiance=5,19, Transcend=5,64), porém a alteração não foi perceptível para a Coca-Cola e saliva artificial (ΔE<3,7). Os braquetes submetidos à escovação apresentaram médias de alteração de cor significativamente menores e não perceptíveis, exceto para o chá preto. Rugosidade: Média Ra do Allure =0,277, Inspire Ice =0,262, Radiance=0,177, Transcend=0,367. A rugosidade variou apenas com o tempo de imersão. Cocluiu-se que houve alteração de cor dos braquetes cerâmicos quando imersos nas soluções, porém, apenas com o café... / This study aimed to analyze in vitro the color stability and surface roughness of ceramic brackets after immersion in dye solutions. Seven ceramic brackets, upper right central incisor of four commercial brands were tested: two monocrystalline and two polycrystalline. The brackets were immersed separately in four staining solutions (coffee, red wine, Coca-Cola and black tea) and in artificial saliva at following times: T0 (initial measurement), T1, T2, T3 and T4 (24 hours, 7.14 and 21 days respectively). Other seven brackets of each brand were immersed in the same solutions and at same times as previous, but with brushing daily. The changes in color were evaluated by reflectance spectrophotometer and the surface roughness by a surface roughness gauger. The data were evaluated by Multivariate Analysis Profiles, Analysis of Variance (ANOVA), Multiple Comparison Test of means and Test t Student. Based on the results, there was perceptible change of color in all ceramic brackets after 21 days of immersion in coffee solution (ΔE of Allure = 7.61, Inspire Ice = 6,09, Radiance=6,69, Transcend=7,44), black tea (ΔE of Allure = 6,24, Inspire Ice = 5,21, Radiance=6,51, Transcend=6,14) and red wine (ΔE do Allure =6,49 , Inspire Ice = 4,76, Radiance=5,19, Transcend=5,64), but the change was not perceptible to the Coca-Cola and artificial saliva (ΔE <3.7). The brackets that were submitted to brushing showed average color change significantly smaller and not visible, except for black tea. Roughness: Ra Average of Allure = 0.277, Inspire Ice = 0.262, Radiance = 0.177, Transcend = 0.367. The roughness changed with the immersion time. It was cocluded that there was a change in color of ceramic brackets when immersed in the solutions, but only with coffee, black tea and red wine that change was perceptible. The monocrystalline or polycrystalline structure doesn’t affect in the form of staining... 9Complete abstract click electronic access below)
49

Efeito do tempo de fotoativação na resistência de união ao cisalhamento de bráquetes metálicos e cerâmicos à superfície cerâmica

Carvalho, Marcela Batista Pereira de 28 August 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade em Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2013. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2013-11-19T15:44:37Z No. of bitstreams: 1 2013_MarcelaBatistaPereiraCarvalho.pdf: 19426211 bytes, checksum: dbf19bbb4b0468de7b3f32a7979dd79e (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-12-04T10:33:26Z (GMT) No. of bitstreams: 1 2013_MarcelaBatistaPereiraCarvalho.pdf: 19426211 bytes, checksum: dbf19bbb4b0468de7b3f32a7979dd79e (MD5) / Made available in DSpace on 2013-12-04T10:33:26Z (GMT). No. of bitstreams: 1 2013_MarcelaBatistaPereiraCarvalho.pdf: 19426211 bytes, checksum: dbf19bbb4b0468de7b3f32a7979dd79e (MD5) / O objetivo do presente estudo foi avaliar a resistência de união de bráquetes metálicos e cerâmicos à superfície cerâmica, analisando dois tempos de fotoativação com aparelho LED (light emitting diode). O ensaio de resistência de união foi realizado em bráquetes de aço inoxidável (Morelli), cerâmicos monocristalinos (Inspire ICE) e cerâmicos policristalinos (InVu). Os discos cerâmicos (IPS Empress Esthetic) incluídos em cilindros de resina acrílica foram condicionados com ácido fluorídrico gel a 10% por 60 segundos. Após a aplicação de silano, por 30 segundos, os bráquetes foram colados seguindo o protocolo recomendado para o compósito Transbond XT. Os corpos-de-prova, para cada tipo de bráquete, foram distribuídos aleatoriamente em 2 grupos (n=15) conforme o tempo de fotoativação, de 20 e 10 segundos, usando o aparelho LED Bluephase. Todos os corpos-de-prova foram armazenados a 37°C e 100% de umidade por 24 horas, posteriormente, termociclados (1000 ciclos, de 5°C à 55°C) e retornaram ao ambiente úmido de armazenamento. O teste de cisalhamento foi realizado após 24 horas na máquina universal de ensaio a uma velocidade de 1 mm/min. Em seguida, o Índice Remanescente de Adesivo (IRA) foi avaliado. Os dados foram submetidos à Análise de Variância e ao teste de Tukey (5%). Todos os bráquetes fotoativados por 20 segundos apresentaram valores de resistência de união significativamente (p<0,05) superiores aos bráquetes fotoativados por 10 segundos. Os bráquetes cerâmicos monocristalinos apresentaram valores de resistência de união significativamente (p<0,05) superiores aos bráquetes cerâmicos policristalinos e de aço inoxidável, sendo estes, estatisticamente semelhantes (p>0,05) quando fotoativados por 20 segundos. Para o tempo de fotoativação de 10 segundos, os bráquetes cerâmicos policristalinos apresentaram valores superiores (p<0,05) aos de aço inoxidável. Enquanto nos grupos de 20 segundos de tempo de fotoativação, o escore 1 (IRA) foi observado com predominância para os bráquetes de aço inoxidável e cerâmicos monocristalinos, e o escore 3 para o bráquete cerâmico policristalino, nos grupos de 10 segundos, o bráquete cerâmico monocristalino apresentou predominância do escore 1, e escore 3 para os bráquetes de aço inoxidável e cerâmicos policristalinos. Pôde-se concluir que o tempo de fotoativação teve influência significativa na resistência de união de bráquetes metálicos e cerâmicos à superfície cerâmica e que os bráquetes cerâmicos monocristalinos apresentaram os maiores valores de resistência de união. ______________________________________________________________________________ ABSTRACT / The aim of this study was to evaluate the bond strength of metallic and ceramic brackets bonded to ceramic, by testing two photoactivation times using a LED (light emitting diode) curing unit. Bond strength testing was performed on stainless steel brackets (Morelli), monocrystalline ceramic brackets (Inspire ICE), and polycrystalline ceramic brackets (InVu). Disc-shaped-ceramic specimens (IPS Empress Esthetic) embedded in acrylic resin blocks were etched with 10% hydrofluoric acid gel for 60 seconds. After application of silane for 30 seconds, brackets were bonded following the protocol recommended for Transbond XT. Specimens for each bracket type were assigned to two groups (n=15), according to the photoactivation times: 20 seconds or 10 seconds, using a Bluephase LED unit. All specimens were stored at 37°C and 100% relative humidity for 24 hours, then thermocycled (1,000 cycles, 5°C to 55°C), and they returned to the humid storage conditions. Shear bond testing was carried out after 24 hours with a universal testing machine at a crosshead speed of 1-mm/min. Adhesive Remnant Index (ARI) scores were evaluated. Data were subjected to two-way ANOVA and Tukey's test. All bracket types photoactivated for 20 seconds showed significantly (p<0.05) higher bond strength compared to specimens photoactivated for 10 seconds. Monocrystalline brackets showed significantly (p<0.05) higher bond strength compared to polycrystalline and stainless steel brackets, which are statistically similar (p>0,05) when photoactivated for 20 seconds. For 10 seconds photoactivation time, the polycrystalline ceramic brackets showed higher values (p<0.05) than stainless steel brackets. For the 20 second photoactivation time group, an ARI score 1 was observed with predominance for SS and monocrystalline brackets, and score 3 for polycrystalline brackets; for the 10 second photoactivation time group, an ARI score 1 was observed with predominance for the monocrystalline brackets, and score 3 for stainless steel and polycrystalline brackets. In conclusion, photoactivation time had significant influence on the bond strength of metallic and ceramic brackets bonded to a ceramic surface, and monocrystalline brackets showed the highest bond strength values.
50

Avaliação clinica e laboratorial da colagem de braquetes metalicos com compositos ortodonticos / Clinical and laboratory evaluation of metallic brackets bonded with orthodontic composites

Romano, Fabio Lourenço 13 August 2018 (has links)
Orientadores: Maria Beatriz Borges de Araujo Magnani, Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T18:10:24Z (GMT). No. of bitstreams: 1 Romano_FabioLourenco_D.pdf: 2297898 bytes, checksum: 5ecd4de7f0dd31f6b954e634f32893ef (MD5) Previous issue date: 2009 / Resumo: O objetivo neste estudo foi avaliar clinicamente e em laboratório, a taxa de descolagem e a resistência ao cisalhamento de bráquetes metálicos colados com compósitos ortodônticos. O experimento clínico consistiu de 20 pacientes (10,5-15,1 anos de idade), que procuraram tratamento ortodôntico corretivo. Nestes pacientes foram colados bráquetes de 2° pré-molar a 2° pré-molar no arco superior e inferior com os sistemas adesivos: Concise Ortodôntico, Transbond XT convencional, Transbond XT sem agente de união e Transbond XT em esmalte preparado com ácido-primer Transbond Plus Self Etching Primer (TPSEP). Todos os sistemas foram utilizados em todos os pacientes, em rodízio pelos quadrantes, sendo que, a mesma sequência de colagem se repetiu em cada cinco pacientes. Arcos iniciais foram inseridos uma semana após a colagem dos bráquetes. Os pacientes foram avaliados durante seis meses para quantificar o número de bráquetes descolados. Ao final do período de observação ocorreram 8 descolagens com Concise Ortodôntico, 2 com Transbond XT convencional, 9 com Transbond XT sem agente de união e 1 com TPSEP + Transbond XT. Pelo Método de Kaplan-Meier foram encontradas diferenças estatísticas significantes na taxa de descolagem entre os materiais (P=0,0198) e o teste Logrank identificou estas diferenças. O Transbond XT convencional e TPSEP + Transbond XT foram estatisticamente superiores (apresentaram menos descolagens) em relação ao Concise Ortodôntico e Transbond XT sem agente de união (P<0,05). Entre os materiais Transbond XT convencional e TPSEP + Transbond XT não foram encontradas diferenças estatísticas significantes, assim como, entre Concise Ortodôntico e Transbond XT sem agente de união (P>0,05). O experimento laboratorial teve como objetivo avaliar a resistência ao cisalhamento de bráquetes metálicos colados com o novo compósito ortodôntico Transbond Plus Color Change (TPCC, 3M Unitek) em diferentes preparações de esmalte e analisar após a descolagem o Índice de Remanescente de Adesivo (IRA). Foram utilizados 72 pré-molares humanos divididos em seis grupos (n=12). No Grupo 1 (controle) foi utilizado o compósito Transbond XT convencionalmente. Nos demais grupos (2 a 6) utilizou-se o TPCC nas seguintes condições de esmalte: ácido fosfórico e XT primer; ácido-primer TPSEP; somente ácido fosfórico; ácido fosfórico, XT primer e saliva; TPSEP e saliva, respectivamente. Após a colagem dos bráquetes e fotoativação, os corpos de prova foram armazenados em água destilada em estufa a 37°C por 24 horas. Em seguida, os bráquetes foram carregados em máquina Instron à velocidade de 0,5 mm/min. e o IRA avaliado em lupa estereoscópica. Osvalores médios de resistência ao cisalhamento (MPa) foram: Grupo 1- 24,6; Grupo 2-18,7; Grupo 3-17,5; Grupo 4-19,7; Grupo 5-17,5 e Grupo 6-14,8. Os dados foram submetidos à ANOVA e ao teste de Tukey (5%). O Grupo 1 apresentou maior média e diferiu estatisticamente dos grupos 3, 5 e 6 (P<0,05) e sem diferença estatística significante em relação aos grupos 2 e 4 (P>0,05). Entre os grupos 2, 3, 4, 5 e 6 não foram encontradas diferenças estatísticas significantes (P>0,05). A colagem de bráquetes com TPCC apresentou valores comparáveis ao Transbond XT convencional e o tipo de preparo de superfície não influenciou esta adesão / Abstract: The aim of this study was to assess clinically and laboratory the bracket failure rate and shear bond strength of metallic brackets bonded with orthodontic composites. The in vivo study consisted of 20 patients aged between 10.5 to 15.1 years old who had sought corrective orthodontic treatment. Brackets were bonded of the second premolar - second premolar to their upper and lower arches using the adhesive systems: Orthodontic Concise, conventional Transbond XT, Transbond XT without primer, and Transbond XT applied to enamel etched with Transbond Plus Self-etching Primer (TPSEP). All the adhesive systems were used in all patients on a quadrant-rotation basis by repeating the same bonding sequence in every 5 patients. Initial archwires were inserted a week after the brackets bonding. The patients were evaluated during six months in order to quantify the number of brackets failure regarding each adhesive system. At the end of the observation period, 8 brackets failure rates were observed for Orthodontic Concise, 2 for conventional Transbond XT, 9 for Transbond XT without primer, and 1 with Transbond XT + TPSEP. By using the Kaplan-Meier methods, statistically significant differences were found between the materials (p=.0198), and the Logrank test identified these differences. It was observed that conventional Transbond XT and Transbond XT + TPSEP were statistically superior (fewer debonded brackets) compared to Orthodontic Concise and Transbond XT without primer (P<.05). However, no statistically significant differences were found between conventional Transbond XT and TPSEP + Transbond XT as well as between Orthodontic Concise and Transbond XT without primer (P>.05). The in vitro study aimed at assessing the shear bond strength of metallic brackets bonded to different enamel surfaces using the Transbond Plus Color Change composite (TPCC, 3M Unitek) as well as to analyse the Adhesive Remnant Index (ARI). Seventy-two human premolars were used for study, with all samples being divided into six groups (n =12). In Group 1 (control), Transbond XT composite was conventionally used. In other groups (2-6), TPCC was used under the following enamel conditions: phosphoric acid and XT primer; TPSEP; phosphoric acid only; phosphoric acid, XT primer and saliva; and TPSEP and saliva, respectively. After bracket bonding and photo-activation, the samples were stored in distilled water for 24 hours at 37°C in a stove. Next, the brackets were debonded by using an Instron machine at crosshead speed of 0.5 mm/min, and the ARI were evaluated by using a stereoscopic magnifying glass. The mean shear strength values (MPa) were the following: Group 1, 24.6; Group 2, 18.7; Group 3, 17.5; Group 4, 19.7; Group 5, 17.5; and Group 6, 14.8. Data were submitted to both ANOVA and Tukey's test (5%). Group 1 was found to be statistically superior to Groups 3, 5, and 6 (P<.05), with no statistically significant difference compared to Groups 2 and 4 (P>.05). No statistically significant differences were found between Groups 2, 3, 4, 5 and 6 (P>.05). The bracket bonding using TPCC composite showed values comparable to the conventional Transbond XT, and the type of enamel preparation had no influence / Doutorado / Ortodontia / Doutor em Radiologia Odontológica

Page generated in 0.0483 seconds