• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 141
  • 115
  • 32
  • 28
  • 14
  • 9
  • 8
  • 6
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 402
  • 402
  • 159
  • 74
  • 60
  • 48
  • 37
  • 35
  • 34
  • 30
  • 29
  • 29
  • 28
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

A study of CAD.

January 1986 (has links)
CAM applications for the Hong Kong garment industry ; by Yung Kai-tai. / Bibliography: leaf 55 / Thesis (M.B.A.)--Chinese University of Hong Kong, 1986
182

Avaliação da percepção estética de prótese óculo-palpebral confeccionada pelo método convencional e pelo sistema CAD/CAM / Evaluation of the aesthetic perception on oculopalpebral prosthesis obtained by the conventional method and by the CAD/CAM system

Kawabata, Simone Cristina 13 July 2016 (has links)
O uso do Sistema CAD/CAM já é bastante consagrado na Odontologia, não sendo diferente na reabilitação facial. Traz diversas facilidades, porém poucos trabalhos relatam as reabilitações da região óculo-palpebral. Nesse estudo, a aquisição de imagem tridimensional foi feita com o uso de um escâner de superfície a laser, FARO Edge ScanArm®, protegendo-se o olho contralateral com uso de lente gelatinosa preta; método que demonstrou eficiência na obtenção de imagem de pálpebras abertas para confecção de protótipo reverso. Foram selecionados 10 pacientes com exenteração de órbita, de ambos os gêneros, sendo 5 com mutilação à esquerda e 5 à direita. Todos os pacientes receberam duas próteses óculo-palpebrais, uma confeccionada pelo método convencional e outra pelo sistema CAD/CAM. As reabilitações foram registradas fotograficamente e avaliadas por 30 indivíduos leigos, 3 especialistas em prótese bucomaxilofacial e pelos próprios pacientes, usando-se a Escala VAS. Para avaliar a variação intraexaminador, 15 leigos repetiram a avaliação com intervalo de uma semana, assim como os 3 especialistas. Os resultados demonstraram consistência interna e uma boa reprodutibilidade dos dados em todos os grupos. A percepção estética foi melhor avaliada nas próteses obtidas pelo método convencional; entretanto, a relevância da diferença observada entre os dois métodos foi avaliada como razoável. / The use of CAD/CAM system is already an established method in Dentistry, no different in facial rehabilitation. It brings several facilities, but few studies have already reported the rehabilitations of the orbital area. In this research the acquisition of the three dimensional image was taken using a surface laser scanner, FARO Edge ScanArm®, protecting the contralateral eye with the use of a black gelatinous contact lens; this method has demonstrated effectiveness in getting image with open eyelids for making reverse prototype. 10 patients were select with orbit exenteration, of both genders, 5 with left mutilation and 5 with right. All patients received two oculopalpebral prostheses, one obtained by the conventional method and another by the CAD/CAM system. The rehabilitations were photo registrated and assessed by 30 lay assessors, 3 bucomaxillofacial prosthetic specialists and by the patients themselves using the VAS Scale. To evaluate the intraexaminer variation, 15 lay assessors repeated the evaluation with one week interval, as did the specialists. The results demonstrated good interexaminer variation and reproducibility of data in all groups. The aesthetic perception was better evaluated in prostheses obtained by the conventional method; however, the relevance of difference between the two methods was assessed as a reasonable one.
183

Avaliação da posição do modelo auricular virtual gerado por imagem captada com escâner a laser e desenvolvimento de dispositivo posicionador 3D / Evaluation of the position of the virtual auricular model generated by image captured by laser scanning and development of 3D positioner device

Marafon, Priscila Galzo 13 March 2013 (has links)
Este trabalho fundamenta a aquisição de modelo digital auricular por meio do escâner de superfície e avalia o posicionamento tridimensional do modelo auricular digital, espelhado segundo medidas antropométricas faciais, com e sem referência anatômica do canal auditivo externo, bem como desenvolve um dispositivo posicionador tridimensional para prótese auricular. Os dados de dez indivíduos voluntários, adultos maiores de 25 anos de idade, não portadores de lesão congênita ou adquirida na região craniofacial e de ambos os gêneros foram submetidos ao Teste dos Postos Sinalizados de Wilcoxon (p0,05) e a medida angular C6 foi avaliada de forma porcentual. Os resultados demonstram que ocorre assimetria nas medidas lineares da posição dos modelos auriculares direitos e esquerdos espelhados nos respectivos lados contralaterais da face sem a referência do conduto auditivo externo, sendo duas vezes mais frequente no espelhamento do modelo auricular esquerdo no lado direito da face. Observa-se menor assimetria dos modelos auriculares direitos espelhados no lado esquerdo da face e simetria na posição dos modelos esquerdos espelhados no lado direito da face, com a referência do conduto auditivo externo. A medida angular C6 apresenta menor assimetria na posição dos modelos auriculares direitos do que nos esquerdos, espelhados nos respectivos lados contralaterais da face, com e sem a referência do conduto auditivo externo. Conclui-se que a utilização do conduto auditivo externo como referência anatômica proporciona melhor simetria linear e angular da posição dos modelos auriculares virtuais direitos e esquerdos, espelhados nos respectivos lados contralaterais da face. O dispositivo posicionador projetado possibilita o ajuste das assimetrias detectadas no espelhamento de modelos auriculares, promovendo a compensação das discrepâncias evidenciadas durante o planejamento virtual para posicionamento do modelo auricular. / This study substantiates the acquisition of auricular digital model, by means of surface scanner, and assesses the placement of three-dimensional auricular digital models, mirrored according to facial anthropometric measurements, with and without anatomical reference of the external auditory canal, as well as developing a prosthetic device for three-dimensional positioning of the mirrored auricular model. The digital data of ten volunteers, adults over 25 years old, not suffering from congenital or acquired lesions in the craniofacial region and of both genders underwent Wilcoxon Ranking Test (p0.05) and angular measurement C6 was assessed as percentage. The results show that occurs asymmetry regarding the linear measurements in the positioning of the right and left ear models when mirrored in their contra lateral side of the face without reference of the external auditory canal, being twice as common in mirroring the left auricular model on the right side of the face. It is observed less asymmetry in the right auricular models mirrored on the left side of the face and symmetry in the positioning of the left models mirrored on the right side of the face, with the reference of the external auditory canal. The angular measurement C6 shows less asymmetry in the positioning of the models right auricular model than in those of the left, mirrored in their contra lateral side of the face, with or without reference to the external auditory canal. The use of the external auditory canal as anatomical reference provides better linear and angular symmetry in positioning the virtual auricular right and left models, mirrored in their contra lateral side of the face The three-dimensional positioner device designed enables the adjustment of the asymmetries found in mirroring the digital auricular models, providing compensation for discrepancies evidenced during the virtual positioning of the auricular model.
184

Automatisierte Akquisition von erfahrungsbasiertem Fertigungswissen im Werkzeug- und Formenbau

Schneider, Thomas 26 January 2012 (has links) (PDF)
Der verschärfte Wettbewerb auf den globalisierten Märkten, wachsender Termindruck sowie steigende Qualitätsanforderungen machen das betriebsspezifische Know-how bei der Anfertigung von Betriebsmitteln zum entscheidenden Wettbewerbsfaktor. Durch die in Werkzeug- und Formenbaubetrieben traditionell anzutreffende Werkstattorganisation wird dieses Wissen individuell durch die Erfahrungen der Facharbeiter gehalten, woraus eine geringe Transparenz der Fertigungsabläufe sowie ein hoher Anteil manueller Tätigkeiten bei der Arbeitsplanung resultiert. Zur Standardisierung und Automatisierung von Fertigungsabläufen ist folglich die Akquisition internen Erfahrungswissens erforderlich, die sowohl bei organisationalen als auch IT-orientierten Wissensmanagement-Ansätzen als hochaufwändig gilt. Anhand vorhandener globaler Modelle wurde in dieser Arbeit ein Ansatz entwickelt, der mit Hilfe maschineller Lernverfahren eine automatisierte Wissensakquisition ermöglicht. Auf Grundlage der abgeleiteten Wissensbedarfe „Werkzeuge“ und „Schnittwerte“ und den besonderen Randbedingungen bei der NC-Programmierung mit Hilfe eines grafisch interaktiven CAM-Systems wurden Verfahren konzipiert, die eine automatisierte Akquisition, Standardisierung und regelbasierte Repräsentation von Erfahrungswissen auf Basis einer großen Anzahl an Fallbeispielen ermöglicht. Die entworfenen Lernverfahren wurden prototypisch implementiert und ihre Funktionsfähigkeit anhand einer Datenbasis mit 24.000 realen Fallbeispielen (1 Fallbeispiel entspricht 1 Operation/NC-Programm) nachgewiesen. Die Plausibilität des akquirierten Wissens sowie seine automatisierte Verarbeitung mit Hilfe moderner kommerzieller CAM-Systeme wurde abschließend durch die NC-Programmierung eines Beispielwerkstücks unter Verwendung einer kommerziellen CAM-Software demonstriert. / The intensive competitive environment on globalized markets, the growing deadline pressure caused by shortened product life cycles as well as increasing quality requirements emphasize the company-specific know-how as a decisive competitive factor for toolmakers. Due to the traditional shop floor organization within toolmaking companies, this knowledge is individually held by experiences of the single skilled worker which a low transparency of manufacturing processes as well as a high degree of manual activities at the operation planning process results from. In that form of representation the existing manufacturing knowledge of the company can not be, independent of individual people, integrated in the value-adding process and hence can not be used consequently. Therefore the standardization and automation of manufacturing processes requires the acquisition of internal experience-based knowledge, what is deemed to be a complex task in organizational as well as in IT-based approaches. Based on existing global models the present work develops an approach that enables an automated acquisition of knowledge using methods of data mining based on an amount of real sample data. For that purpose, methods for the automatic extraction, preparation and structured storage of sample data sourced from a commercial CAM system were developed and prototypically implemented. Based on the specified knowledge demands, „milling tools“ and „cutting data“ as well as the special environment of the shop-floor oriented NC programming by using a graphically interactive CAM system, adequate learning methods were conceived that enable an automated acquisition, standardization and rule based representation of experiential knowledge. The conceived methods were prototypically implemented and their functional capability was verified on the basis of the mentioned amount of real sample data. The plausibility of the acquired knowledge as well as its automated processing capability within modern CAM systems was finally proved by the NC programming of a sample part using the CAM software hyperMILL®.
185

Passividade na interface pr?tese/pilar intermedi?rio de infraestrutura implantossuportadas confeccionadas pela tecnologia CAD/CAM e m?todo convencional

Ara?jo, Gabriela Monteiro de 28 August 2014 (has links)
Made available in DSpace on 2014-12-17T15:43:56Z (GMT). No. of bitstreams: 1 GabrielaMA_DISSERT.pdf: 606059 bytes, checksum: cac128da2c04d2e2044a79faa5d2f38c (MD5) Previous issue date: 2014-08-28 / The objective of this research was to evaluate the passivity and strain induced in infrastructures screwed on abutments, made by CAD/CAM technology, and to compare these samples with parts manufactured by conventional casting. Using CAD/CAM technology, 4 samples were made from zirconia (Zircad) and 4 samples were manufactured from cobaltchrome (CoCrcad). The control groups were 4 specimens of cobalt-chrome, made by onepiece casting (CoCrci), for a total of 12 infrastructures. To evaluate the passivity, the infraestructures were installed on the abutments. One end was tightened and the vertical gap between the infrastructure and the prosthetic abutment was measured with scanning electron microscopy (250?). The mean strain in these infrastructures was analyzed via the photoelasticity test. A significant difference (p = 0.000) in passivity was observed between the control (CoCrci) and sample groups (CoCrcad and CoCrci). CoCrcad exhibited the best value of passivity (48.76 ? 13.45 μm) and CoCrci the worst (187.55 ? 103.63 μm), Zircad presented an intermediate value (103.81 ? 43.15 μm). When compared to the other groups, CoCrci showed the highest mean strain around the implants (17.19 ? 7.22 kPa). It was concluded that the zirconia infrastructure made by CAD / CAM showed a higher vertical marginal misfit than those made in cobalt-chromium alloy with the same methodology, however, the tension generated in the implants was similar. The CAD/CAM technology is more accurate for passivity and mean strain of infrastructure screwed on abutments than conventional manufacturing techniques / O objetivo desta pesquisa foi avaliar a passividade e a tens?o induzida em infraestruturas parafusadas sobre pilares, confeccionadas por tecnologia CAD / CAM, e comparar com infraestruturas fabricadas por fundi??o convencional. Com a utiliza??o da tecnologia de CAD / CAM, 4 infraestruturas de 3 elementos foram confeccionadas em zirc?nia (ZirCAD) e 4 em cobalto-cromo (CoCrcad). Para o grupo controle foram utilizadas 4 infraestruturas em cobalto- cromo, confeccionadas por fundi??o em monobloco (CoCrci), totalizando 12 infraestruturas. Para avaliar a passividade, as infraestruturas foram instaladas sobre os pilares. Uma extremidade foi apertada e a diferen?a vertical entre a infraestrutura e o pilar prot?tico na outra extremidade foi medida com microscopia eletr?nica de varredura (250 ?). A tens?o m?dia gerada aos implantes foi analisada por meio do teste de fotoelasticidade. An?lise de Vari?ncia (ANOVA) foi aplicada a fim de comparar as m?dias entre os grupos para a passividade e ?rea de tens?o. Com isso, para a compara??o dois a dois entre os grupos, o teste T foi utilizado para a avalia??o da passividade e teste Tukey para a ?rea de tens?o. Foi observada uma diferen?a significativa (p = 0,000) na passividade entre os grupos controle (CoCrci) e demais amostras (CoCrcad e CoCrci). CoCrcad exibiu o menor valor de passividade (48,76 ? 13:45 μm) e CoCrci o maior (187,55 ? 103,63 μm), Zircad apresentou um valor intermedi?rio (103.81 ? 43.15 μm). Quando comparado com os outros grupos, CoCrci apresentou a maior m?dia tens?o ao redor dos implantes (17,19 ? 7,22 kPa). Concluiuse que as pe?as confeccionadas por CAD/CAM em zirc?nia apresentaram uma maior desadapta??o marginal vertical do que aquelas fabricadas em cobalto-cromo com a mesma metodologia, por?m, a tens?o gerada aos implantes foi semelhante. Entretanto, a tecnologia CAD/CAM foi mais precisa do que a t?cnica convencional de fabrica??o de infraestruturas parafusadas sobre pilares prot?ticos, tanto em rela??o ao desajuste marginal, quanto ? tens?o gerada aos implantes
186

UMA METODOLOGIA DE INTEGRAÇÃO CAD/CAM ATRAVÉS DA APLICAÇÃO DE CICLOS DE USINAGEM NA PROGRAMAÇÃO CNC / A CAD/CAM INTEGRATED METHODOLOGY THROUGH THE APPLICATION OF MACHINING CYCLES IN CNC PROGRAMMING

Oliveira, Claudio André Lopes de 23 December 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The use of computer resources for machinery programming with Computer Numeric Control (CNC) has become increasingly more necessary in manufacturing companies. The objective is to reduce unproductive time, to optimize programming process, to decrease possibility of error caused by manual programming and to decrease the time that the machine is not being used. Softwares employed for the programming of CNC machines, known as CAM, are programs that, among other functions, enable the automatic generation of CNC programs, through the calculus of the tool path, from the geometric representation of the available part in computer systems presented virtually. When their integration occurs, we obtain CAD/CAM systems that currently, due to the great advance of technologies, help the creation of shapes and the handling of dimensions, thus enabling the programming of several kinds of numerically-driven equipment. Due to a great array of resources offered by these programs, its cost is high. Therefore, the purchase of these programs by companies is impracticable. In addition, these companies do not need all the great array of resources to deal with low complexity geometry. By considering these aspects, the objective of this study is to develop a low-cost CAD/CAM integrated methodology to apply in fixed cycles for milling and drilling, existing in the numeric comand of machine tools. In order to analyze the technique, a system using a CAD software was designed. Through its optimization resources, routines for programming fixed cycles of a machine tool (milling) with three-axle programmable CNC were created. The results demonstrated viability of this proposal as it was possible to obtain a CAD/CAM system for specific application. / A utilização de recursos computacionais para a programação de máquinas com Comando Numérico Computadorizado (CNC) tem se tornado cada vez mais necessária nas empresas de manufatura. Esses recursos permitem a redução dos tempos improdutivos, a otimização do processo de programação, a diminuição da possibilidade de erro causado pela programação manual e do tempo de máquina parada. Os softwares utilizados para a programação de máquinas CNCs, conhecidos pela sigla CAM (Manufatura assistida por computador), são programas que, entre outras funções, possibilitam a geração automática de programas CNC através do cálculo do caminho da ferramenta, a partir da representação geométrica da peça disponível na forma virtual em sistemas computacionais de auxilio ao projeto CAD (desenho assistido por computador). Da integração desses sistemas, têm-se os sistemas CAD/CAM, que hoje, devido ao avançado grau de desenvolvimento das tecnologias, auxiliam na criação de formas e manipulação de dimensões possibilitando a programação de diversos tipos de equipamentos comandados numericamente. Devido à gama de recursos oferecida por esses programas, seu custo é elevado, o que torna sua aquisição inviável para pequenas empresas, que, muitas vezes, não necessitam de todos esses recursos por trabalharem com geometria de pouca complexidade. Levando em consideração esses aspectos, o objetivo deste trabalho é desenvolver uma metodologia de integração CAD/CAM de baixo custo para aplicação de ciclos fixos para usinagem em fresamento e furação, existentes no comando numérico de máquinas-ferramenta. Para analisar a técnica, foi desenvolvido um sistema utilizando um software de CAD, a partir do qual, através de seus recursos de otimização e automatização, foram criadas rotinas para programação dos ciclos fixos de uma fresadora CNC de 3 eixos programáveis. Os resultados demonstraram a viabilidade dessa proposta, pois foi possível obter um sistema CAD/CAM para aplicação específica.
187

Avaliação de diferentes métodos de obtenção do modelo virtual no sistema CAD/CAM CEREC por meio de microtomografia computadorizada

Carneiro, Thiago de Almeida Prado Naves 26 February 2013 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Objectives: The current study evaluated the different methods of virtual model obtention fabricated by CEREC CAD/CAM system, using micro-computed tomography to compare marginal gap on ceramic crowns. Methods: A human premolar (#21) was prepared for an all-ceramic crown. Twenty different digital impressions, designs and crowns were made by the CEREC CAD/CAM system after virtual model obtention by four different methods. The typodont, with the #21 (T), was powdered using a thin layer of titanium dioxide (Sirona) and scanned with the CEREC 3D BlueCam. Regular impressions (RI) were taken of the typodont and were scanned. Master casts (MC) were obtained and scanned. After that, the master casts were powdered (PMC) using a thin layer of titanium dioxide and scanned again. All the crowns were made by feldspathic ceramics (VITABLOCS Mark II) in the InLab milling unit - SIRONA. Each crown was fixed and scanned using a micro-CT to obtain images for marginal gap measurements. The Micro-CT allowed the measurement of marginal gaps at 52 locations in each specimen, totalizing 260 values of vertical misfit and 260 of horizontal misfit. Three calibrated examiners and the mean values were obtained. Results: Considering the percentage of vertical marginal gap up to 75 μm, the results were: T 71.5%, RI 49.2%, MC 69.6% and PMC 71.2%. The percentages of horizontal measurements with overextension of the crowns were: T 8.5%, RI 0%, MC 0.8% and PMC 3.8%, and Conclusion: Based on the results of this study, obtaining virtual models by scanning the mouth or the master cast, with or without powder, showed acceptable values of marginal gap on feldspathic ceramic crowns (VITABLOCS Mark II) manufactured on chairside CEREC CAD/CAM system, considering up to 75μm (our reference value). The higher results of marginal gap for regular impression suggest that is preferable to scan directly the mouth or the master cast. / Objetivos: O presente estudo avaliou diferentes métodos de obtenção do modelo virtual pelo sistema CEREC CAD/CAM, utilizando micro-tomografia computadorizada para comparar a desadaptação marginal em coroas de cerâmica pura obtidas pelo sistema. Métodos: um pré-molar humano (34) foi preparado para uma coroa de cerâmica pura. Impressões digitais, por quatro métodos diferentes foram feitas pelo sistema CEREC CAD / CAM, e as coroas projetadas após obtenção do modelo virtual. Para o grupo Boca (T), o dente humano montado em Typodont foi pulverizado usando uma fina camada de dióxido de titânio (Sirona) e digitalizado com o 3D CEREC BlueCam. Para o grupo Molde (RI), moldagens foram realizadas do Typodont e foram digitalizadas após aplicação de dióxido de titânio. Depois, os modelos de gesso (CM) foram obtidos, a partir destes mesmos moldes, e digitalizados. E por último, os modelos de gesso (PCM) já digitalizados foram submetidos à aplicação de dióxido de titânio e foram digitalizados novamente. Todas as coroas foram feitas por cerâmica feldspática (VITABLOCS Mark II) na unidade de usinagem InLab - Sirona. Cada coroa foi fixada e analisada usando um micro-CT para obter imagens para medições de fenda marginal. O Micro-CT permitiu a medida de desadaptações marginais em 52 locais em cada amostra, totalizando 260 valores de desajuste vertical e 260 de desajuste horizontal. Três examinadores calibrados fizeram as medições e os valores médios foram obtidos. Resultados: Considerando o percentual de fenda marginal vertical de até 75 μm, os resultados foram: 71,5% T, RI 49,2%, 69,6% MC e PMC 71,2%. As porcentagens de medidas horizontais com sobre extensão das coroas foram: T 8,5%, RI 0%, 0,8% e MC PMC 3,8%. Conclusão: Com base nos resultados deste estudo, a obtenção de modelos virtuais, diretamente da boca ou de modelos de gesso, com ou sem aplicação de pó, apresentaram valores aceitáveis de desadaptação marginal em coroas de cerâmica feldspática (VITABLOCS Mark II), fabricadas em consultório pelo sistema CAD / CAM CEREC, considerando 75μm (nosso valor de referência). Os valores mais elevados de desadaptação marginal foram encontrados na digitalização dos moldes e sugerem que é preferível digitalizar diretamente da boca ou de modelos de gesso. / Mestre em Odontologia
188

Possibilidades da produção artística via prototipagem rápida = processos CAD/CAM na elaboração e confecção de obras de arte e o vislumbre de um percurso poético individualizado neste ensaio / Possibilities of Art via Rapid Prototyping : using CAD/CAM systems to create art works and a glimpse of a poetic route individualized essay

Cóser, Thiago José 16 August 2018 (has links)
Orientador: Marco Antonio Alves do Valle / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Artes / Made available in DSpace on 2018-08-16T05:43:10Z (GMT). No. of bitstreams: 1 Coser_ThiagoJose_M.pdf: 5818410 bytes, checksum: 0f24a09de35a58913936bf66980dd539 (MD5) Previous issue date: 2010 / Resumo: Este trabalho apresenta uma pesquisa prática sobre o uso de tecnologias CAD/CAM com foco no uso de prototipagem rápida em Arte. O trabalho está organizado de modo a explicar a tecnologia empregada, apresentando uma seleção de principais artistas que se utilizam de PR para desenvolver suas obras. Por fim há uma produção poética pessoal, com a intenção de situar a relevância deste discurso na história da Arte / Abstract: This work presents a practical research on the use of CAD / CAM technologies focusing on rapid prototyping use in Art. The work is organized to explain the technology used, presenting a selection of main artists who use PR to develop their works. Finally there is a personal poetic production, with the intention to place the relevance of this discourse in the history of Art / Mestrado / Artes / Mestre em Artes
189

Desadaptação marginal vertical de coroas confeccionadas com cerâmica no sistema computadorizado

Ademir Kiffer 08 August 2007 (has links)
O objetivo deste estudo foi avaliar in vitro a desadaptação cervical vertical de coroas confeccionadas com o sistema CEREC 3 utilizando dosi diferentes materiais para confecção de troquéis. Um modelo padrão em níquel-cromo foi confeccionado nas dimensões convencionais para o preparo de um canino superior. A partir da moldagem com silicone de adição do modelo mestre foram obtidos cinco troquéis com gesso Herostone (grupo 1) e conco com gesso CAM-base (grupo 2). Aos troquéis de gesso Herostone foi aplicado uma substância de contraste (CEREC powder). Os troquéis foram escaneados utilizando o sistema CEREC 3, por profissional calibrado, observando as orientações do fabricante. Dez coroas cerâmicas foram fresadas a partir das imagens obtidas no escaneamento. Com a utilização de um disco diamantado, foram marcados quatro pontos para medição da desadaptação marginal vertical no modelo padrão: vestibular, lingual, mesial e distal. As coroas forma fixadas no modelo padrão com adesivo à base de cianocrilato e posteriormente o conjunto modelo-padrão/coroa foram levados à observação no microscópio eletrônico de varredura sendo realizada quatro leituras em cada ponto, para obter a média, que foi considerado o valor da mensuração. Os resultados foram submetidos ao tratamento estatístico, aplicando-se os testes ANOVAOne Way e Tukey. Concluiu-se que as coroas confeccionadas com gesso CAM-base apresentaram menor desadaptação marginal vertical (69 um) em relação às produzidas com gesso Herestone mais aplicação CERC power (88 um). / The purpose of this study was to evaluate in vitro the inability to adapt marginal crown biult with the CERC 3 system use two unlike materials to making the die. A nickel-chromium pattern was made in conventional prportion an upper canine. A pattern model was impressing by adicion silicone and was made 5 dies with gypsum Herostone (group 1) and 5 dies with CAM-base gypsum (group 2). The dies were applied a contrast substance power CEREC. Those dies were scannied using a CEREC 3 system by qualified person, paying attention to the users guide. Ten ceramics crowns were passed a milling attending the images copied. Sing a diamond disk, were set four points to measure the marginal adapt into the pattern; bucal, lingual, mesial and distal. Those crowns were fixed into pattern with sticking made by cianocrilate and lately the pattern/crown were took get observation at the scanning electron microcopy, in prder to do the measures, were made four lectures in each point. The results were submitted to the statistics treatment, wich was applied the Anova one-way and Tuckey testis. Was achieved that the crowns made by gypsium CAM-base seemed less marginal desadaptation than respecting the does produced by gypsum Herostone plus the powder CEREC.
190

Avaliação da percepção estética de prótese óculo-palpebral confeccionada pelo método convencional e pelo sistema CAD/CAM / Evaluation of the aesthetic perception on oculopalpebral prosthesis obtained by the conventional method and by the CAD/CAM system

Simone Cristina Kawabata 13 July 2016 (has links)
O uso do Sistema CAD/CAM já é bastante consagrado na Odontologia, não sendo diferente na reabilitação facial. Traz diversas facilidades, porém poucos trabalhos relatam as reabilitações da região óculo-palpebral. Nesse estudo, a aquisição de imagem tridimensional foi feita com o uso de um escâner de superfície a laser, FARO Edge ScanArm®, protegendo-se o olho contralateral com uso de lente gelatinosa preta; método que demonstrou eficiência na obtenção de imagem de pálpebras abertas para confecção de protótipo reverso. Foram selecionados 10 pacientes com exenteração de órbita, de ambos os gêneros, sendo 5 com mutilação à esquerda e 5 à direita. Todos os pacientes receberam duas próteses óculo-palpebrais, uma confeccionada pelo método convencional e outra pelo sistema CAD/CAM. As reabilitações foram registradas fotograficamente e avaliadas por 30 indivíduos leigos, 3 especialistas em prótese bucomaxilofacial e pelos próprios pacientes, usando-se a Escala VAS. Para avaliar a variação intraexaminador, 15 leigos repetiram a avaliação com intervalo de uma semana, assim como os 3 especialistas. Os resultados demonstraram consistência interna e uma boa reprodutibilidade dos dados em todos os grupos. A percepção estética foi melhor avaliada nas próteses obtidas pelo método convencional; entretanto, a relevância da diferença observada entre os dois métodos foi avaliada como razoável. / The use of CAD/CAM system is already an established method in Dentistry, no different in facial rehabilitation. It brings several facilities, but few studies have already reported the rehabilitations of the orbital area. In this research the acquisition of the three dimensional image was taken using a surface laser scanner, FARO Edge ScanArm®, protecting the contralateral eye with the use of a black gelatinous contact lens; this method has demonstrated effectiveness in getting image with open eyelids for making reverse prototype. 10 patients were select with orbit exenteration, of both genders, 5 with left mutilation and 5 with right. All patients received two oculopalpebral prostheses, one obtained by the conventional method and another by the CAD/CAM system. The rehabilitations were photo registrated and assessed by 30 lay assessors, 3 bucomaxillofacial prosthetic specialists and by the patients themselves using the VAS Scale. To evaluate the intraexaminer variation, 15 lay assessors repeated the evaluation with one week interval, as did the specialists. The results demonstrated good interexaminer variation and reproducibility of data in all groups. The aesthetic perception was better evaluated in prostheses obtained by the conventional method; however, the relevance of difference between the two methods was assessed as a reasonable one.

Page generated in 0.0309 seconds