• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 1
  • Tagged with
  • 26
  • 26
  • 26
  • 22
  • 22
  • 8
  • 7
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo do pior caso na validação de limpeza de equipamentos de produção de radiofármacos de reagentes liofilizados. Validação de metodologia de carbono orgânico total / Worst-case study for cleaning validation of equipments in the radiopharmaceutical production of lyophilized reagents. Metodology validation of total organic carbon.

Luciana Valeria Ferrari Machado Porto 18 December 2015 (has links)
Os radiofármacos são definidos como preparações farmacêuticas contendo um radionuclídeo em sua composição, são administrados intravenosamente em sua maioria, e, portanto, o cumprimento dos princípios de Boas Práticas de Fabricação (BPF) é essencial e indispensável à tais produtos. A validação de limpeza é um requisito das BPF e consiste na evidência documentada que demonstra que os procedimentos de limpeza removem os resíduos a níveis pré-determinados de aceitação, garantindo que não haja contaminação cruzada. Uma simplificação da validação dos processos de limpeza é admitida, e consiste na escolha de um produto, denominado de \"pior caso\" ou worst case, para representar a limpeza de todos os equipamentos da mesma linha de produção. Uma das etapas da validação de limpeza é o estabelecimento e validação do método analítico para quantificação do resíduo. O objetivo deste estudo foi estabelecer o pior caso para a validação de limpeza dos equipamentos de produção de reagentes liofilizados-RL para marcação com 99mTc, avaliar a utilização do teor de carbono orgânico total (COT) como indicador de limpeza dos equipamentos utilizados na fabricação dos RL, validar o método para determinação de CONP (carbono orgânico não purgável/volátil) e realizar testes de recuperação com o produto escolhido como pior caso. A escolha do produto pior caso baseou-se no cálculo de um índice denominado \"índice para pior caso - Worst Case Index (WCI)\", utilizando informações de solubilidade dos fármacos, dificuldade de limpeza dos equipamentos e taxa de ocupação dos produtos na linha de produção. O produto indicado como pior caso entre os RL foi o MIBI-TEC. Os ensaios de validação do método foram realizados utilizando-se um analisador de carbono modelo TOC-Vwp acoplado a um amostrador automático modelo ASI-V, ambos da marca Shimadzu&reg e controlados por software TOC Control-V Shimadzu&reg. Foi utilizado o método direto de quantificação do CONP. Os parâmetros avaliados na validação do método foram: conformidade do sistema, robustez, linearidade, limites de detecção (LD) e de quantificação (LQ), precisão (repetibilidade e precisão intermediária), e exatidão (recuperação) e foram definidos como: 4% acidificante, 2,5 mL de oxidante, tempo de integração da curva de 4,5 minutos, tempo de sparge de 3,0 minutos e linearidade na faixa de 40-1000 μgL-1, com coeficiente de correlação (r) e soma residual dos mínimos quadrados (r2) > 0,99 respectivamente. LD e LQ para CONP foram 14,25 ppb e 47,52 ppb, respectivamente, repetibilidade entre 0,11 4,47%; a precisão intermediária entre 0,59 a 3,80% e exatidão entre 97,05 - 102,90%. A curva analítica para Mibi mostrou-se linear na faixa de 100-800 μgL-1, com r e r2 > 0,99, apresentando parâmetros similares aos das curvas analíticas de CONP. Os resultados obtidos neste estudo demonstraram que a abordagem do pior caso para validação de limpeza é um meio simples e eficaz para diminuir a complexidade e morosidade do processo de validação, além de proporcionar uma redução nos custos envolvidos nestas atividades. Todos os resultados obtidos nos ensaios de validação de método CONP atenderam as exigências e especificações preconizadas pela norma RE 899/2003 da ANVISA para considerar a metodologia validada. / Radiopharmaceuticals are defined as pharmaceutical preparations containing a radionuclide in their composition, mostly intravenously administered, and therefore compliance with the principles of Good Manufacturing Practices (GMP) is essential and indispensable. Cleaning validation is a requirement of the current GMP, and consists of documented evidence, which demonstrates that the cleaning procedures are able to remove residues to pre-determined acceptance levels, ensuring that no cross contamination occurs. A simplification of cleaning processes validation is accepted, and consists in choosing a product, called \"worst case\", to represent the cleaning processes of all equipment of the same production area. One of the steps of cleaning validation is the establishment and validation of the analytical method to quantify the residue. The aim of this study was to establish the worst case for cleaning validation of equipment in the radiopharmaceutical production of lyophilized reagent (LR) for labeling with 99mTc, evaluate the use of Total Organic Carbon (TOC) content as indicator of equipment cleaning used in the LR manufacture, validate the method of Non-Purgeable Organic Carbon (NPOC), and perform recovery tests with the product chosen as worst case.Worst case products choice was based on the calculation of an index called \"Worst Case Index\" (WCI), using information about drug solubility, difficulty of cleaning the equipment and occupancy rate of the products in line production. The products indicated as worst case was the LR MIBI-TEC. The method validation assays were performed using carbon analyser model TOC-Vwp coupled to an autosampler model ASI-V, both from Shimadzu&reg, controlled by TOC Control-V software. It was used the direct method for NPOC quantification. The parameters evaluated in the validation method were: system suitability, robustness, linearity, detection limit (DL) and quantification limit (QL), precision (repeatability and intermediate precision), and accuracy (recovery) and they were defined as follows: 4% acidifying reagent, 2.5 ml oxidizing reagent, 4.5 minutes integration curve time, 3 minutes sparge time and linearity in 40-1000 μgL-1 range, with correlation coefficient (r) and residual sum of minimum squares (r2) greater than 0.99 respectively. DL and QL for NPOC were 14.25 ppb e 47.52 ppb respectively, repeatability between 0.11 and 4.47%; the intermediate precision between 0.59 and 3.80% and accuracy between 97.05 and 102.90%. The analytical curve for Mibi was linear in 100-800 μgL-1 range with r and r2 greater than 0.99, presenting similar parameters to NPOC analytical curves. The results obtained in this study demonstrated that the worst-case approach to cleaning validation is a simple and effective way to reduce the complexity and slowness of the validation process, and provide a costs reduction involved in these activities. All results obtained in NPOC method validation assays met the requirements and specifications recommended by the RE 899/2003 Resolution from ANVISA to consider the method validated.
12

Controle de compostos orgânicos precursores e subprodutos da desinfecção em mananciais eutrofizados mediante combinação de interozonização e sistemas pós-filtros adsorvedores. / Organic precursor and disinfection by-product control in eutrofic water supplies by means of inter-ozonization and post-filter GAC adsorbers.

Mendes, Ricardo Lazzari 25 May 2010 (has links)
O objetivo deste trabalho foi avaliar o desempenho da combinação dos processos de interozonização e sistemas pós-filtros adsorvedores na remoção de compostos orgânicos precursores e na formação de subprodutos da desinfecção, em particular os trialometanos (THM). Os ensaios foram desenvolvidos com a água filtrada proveniente da estação de tratamento de água do Alto da Boa Vista, localizada no município de São Paulo, tipo convencional, com água bruta oriunda de reservatório com elevado estado de eutrofização. O aparato experimental é constituído de um sistema de ozonização com quatro colunas em série e tempo de detenção hidráulica total de 16 minutos; e, por um sistema de quatro pós-filtros adsorvedores com diferentes tipos de carvão ativado granular, filtros F1 e F3 dotados de carvão mineral (CAG1, betuminoso) e filtros F2 e F4 compostos por carvão vegetal (CAG2, casca de coco) sendo todos operados em paralelo com valores de Tempo de Contato de Leito Vazio (TCLV) entre 15 e 20 minutos. Duas colunas receberam como afluente água filtrada pré-ozonizada (F1 e F2) e as demais colunas apenas água filtrada (F3 e F4). Os resultados indicaram que a ozonização não alterou de forma significativa os parâmetros utilizados para avaliação dos precursores, COT e UV-254 nm, e nem o THM. Inicialmente, os resultados de remoção de COT permaneceram elevados, próximos de 80% caracterizando a saturação dos leitos em torno de 240 dias para os filtros F1 e F3 (CAG1) e apenas 30 dias, com eficiências baixas para os filtros F2 e F4 (CAG2). Para THM a saturação foi próxima de 65 dias para ambos os carvões e as eficiências iniciais foram de 90% e 75%, para os filtros com CAG1 e CAG2, respectivamente. Com todos os leitos saturados, os resultados ainda indicaram boa remoção de compostos causadores de gosto e odor. Neste trabalho, os sistemas de pós-filtros adsorvedores de CAG foram efetivos para o controle das substâncias precursoras e a redução da formação de THMs, com melhores resultados para o carvão mineral CAG1 (betuminoso) independentemente do sistema de interozonização. / The main purpose of this work was to evaluate the performance of a combination of processes - inter-ozonization and post-filter GAC adsorbers systems, on the control of organic precursors and disinfection byproducts, especially trihalomethanes (THM). The experience was conducted with filtered water produced at Alto da Boa Vista conventional WTP, located at São Paulo city, where raw water comes from a high eutrofic lake. The experimental setup consists of an ozonation system with four column shaped contactors arranged in series with 16 minutes total hydraulic detention time; and, a system of four pilot scale adsorbers with different types of granular activated carbon (GAC) media, F1 and F3 filters with mineral GAC media (GAC1, bituminous) and F2 and F4 filters with vegetal GAC media (GAC2, coconut shell), all operated in parallel with empty bed contact time (EBCT) between 15 and 20 minutes. Two columns were fed with filtered and pre-ozonated water (F1 and F2) and the other two were fed with filtered water only (F3 and F4). It was observed that ozonation did not affect significantly results of precursors parameters, TOC and UV-254, and neither THM. Initially, TOC removal remained high, near 80% delineating the bed saturation around 240 days to F1 and F3 filters (GAC1) and only 30 days with low efficiency for filters F2 and F4 (GAC2). The THM bed saturation time was nearly 65 days for both media and initial efficiencies were 90% and 75% to GAC1 and GAC2, respectively. With all beds saturated, still there was a good taste and odor producing substances removal. In this work, the systems of GAC adsorbents post-filters were effective for the control of precursors and to reduce the formation of THM\'s, with better results for the CAG1 (bituminous) regardless of the use of inter-ozonization.
13

ESPACIALIZAÇÃO DO CARBONO E SUAS RELAÇÕES COM A PRODUTIVIDADE DE CULTURAS EM SOLOS SOB PLANTIO DIRETO DE LONGA DURAÇÃO / Spatialization of carbon and its relationship with crop yields in soils under long-term no-tillage

Gonçalves, Daniel Ruiz Potma 23 July 2014 (has links)
Made available in DSpace on 2017-07-25T19:30:46Z (GMT). No. of bitstreams: 1 Daniel Potma.pdf: 2269780 bytes, checksum: 5e498b4886f52a509f48ad0c44a512b3 (MD5) Previous issue date: 2014-07-23 / The total organic C (TOC) of the soil influences their chemical, physical and biological properties, therefore, it's important for the maintenance of soil fertility mainly of tropical soils. But, while the benefits of TOC accumulation on soil quality are well known, there is still little information about its effects on crop yields. The aims of this work were to map the compartments of the TOC on a farm managed for 30 years in no-till system, determine which soil variables that influence the spatial variation of TOC and analyze the relationships between the compartments of TOC and crop yields of soybean, corn and wheat. Deformed samples were collected in all soil classes and all landscape positions in the farm. Were analyzed the TOC, the permanganate oxidized C (POX-C) and the hot water extracted C (HWE-C) and were generated maps with the spatial variation of these variables. The effects of soil properties on the accumulation of TOC and the effect of TOC compartments on yields of soybean, corn and wheat were accessed through regressions and principal component analysis. Aiming to access the contribution of TOC to the crop yields, multiple regressions with the soil variables and yields were adjusted. The higher clay content and the largest biomass apport in Oxisols and the formation of an anaerobic environment in Inceptisols were the main factors that explained the highest contents of TOC observed in the upper thirds of the Oxisols and lower thirds of the Inceptisols. Yields of wheat and soybean showed positive correlation with TOC and total N (TN) and corn yield was positively correlated with HWE-C. The TN and TOC were the variables that contributed most to explain the variations in the wheat yield. / O C orgânico total (COT) do solo exerce influência sobre suas propriedades químicas, físicas e biológicas, sendo assim, importante para a manutenção da fertilidade principalmente de solos tropicais. Porém, embora os benefícios do acúmulo de COT sobre a qualidade do solo sejam bem conhecidos, ainda são escassas informações referentes aos seus efeitos sobre a produtividade de culturas. Os objetivos deste estudo foram mapear os compartimentos de COT em uma fazenda manejada há 30 anos no sistema plantio direto, verificar quais são as variáveis do solo que interferem na variação espacial do COT e analisar as relações entre os compartimentos do COT e a produtividade das culturas da soja, milho e trigo. Foram coletadas amostras deformadas em todas as principais classes de solos da fazenda em todas as posições da paisagem. Foram analisados o COT, o C oxidado por permanganato (C-OXP) e o C extraído por água quente (C-EAQ) e gerados mapas com a variação espacial destas variáveis. Os efeitos dos atributos do solo sobre o acúmulo de COT e dos compartimentos de COT sobre as produtividades da soja, milho e trigo foram acessados através de regressões e análises de componentes principais. Visando acessar a contribuição do COT para as produtividades das culturas foram ajustadas regressões múltiplas com as variáveis do solo e as produtividades. O maior conteúdo de argila e a maior adição de fitomassa nos Latossolos e a formação de um ambiente anaeróbico nos Cambissolos foram os principais fatores que explicaram os maiores conteúdos de COT observados nos terços superior dos Latossolos e inferior dos Cambissolos. As produtividades de trigo e soja apresentaram correlação positiva com o COT e o N total (NT) e a produtividade de milho apresentou correlação positiva com o C-EAQ. As variáveis NT e COT foram as que mais contribuíram para explicar a variação da produtividade de trigo.
14

Controle de compostos orgânicos precursores e subprodutos da desinfecção em mananciais eutrofizados mediante combinação de interozonização e sistemas pós-filtros adsorvedores. / Organic precursor and disinfection by-product control in eutrofic water supplies by means of inter-ozonization and post-filter GAC adsorbers.

Ricardo Lazzari Mendes 25 May 2010 (has links)
O objetivo deste trabalho foi avaliar o desempenho da combinação dos processos de interozonização e sistemas pós-filtros adsorvedores na remoção de compostos orgânicos precursores e na formação de subprodutos da desinfecção, em particular os trialometanos (THM). Os ensaios foram desenvolvidos com a água filtrada proveniente da estação de tratamento de água do Alto da Boa Vista, localizada no município de São Paulo, tipo convencional, com água bruta oriunda de reservatório com elevado estado de eutrofização. O aparato experimental é constituído de um sistema de ozonização com quatro colunas em série e tempo de detenção hidráulica total de 16 minutos; e, por um sistema de quatro pós-filtros adsorvedores com diferentes tipos de carvão ativado granular, filtros F1 e F3 dotados de carvão mineral (CAG1, betuminoso) e filtros F2 e F4 compostos por carvão vegetal (CAG2, casca de coco) sendo todos operados em paralelo com valores de Tempo de Contato de Leito Vazio (TCLV) entre 15 e 20 minutos. Duas colunas receberam como afluente água filtrada pré-ozonizada (F1 e F2) e as demais colunas apenas água filtrada (F3 e F4). Os resultados indicaram que a ozonização não alterou de forma significativa os parâmetros utilizados para avaliação dos precursores, COT e UV-254 nm, e nem o THM. Inicialmente, os resultados de remoção de COT permaneceram elevados, próximos de 80% caracterizando a saturação dos leitos em torno de 240 dias para os filtros F1 e F3 (CAG1) e apenas 30 dias, com eficiências baixas para os filtros F2 e F4 (CAG2). Para THM a saturação foi próxima de 65 dias para ambos os carvões e as eficiências iniciais foram de 90% e 75%, para os filtros com CAG1 e CAG2, respectivamente. Com todos os leitos saturados, os resultados ainda indicaram boa remoção de compostos causadores de gosto e odor. Neste trabalho, os sistemas de pós-filtros adsorvedores de CAG foram efetivos para o controle das substâncias precursoras e a redução da formação de THMs, com melhores resultados para o carvão mineral CAG1 (betuminoso) independentemente do sistema de interozonização. / The main purpose of this work was to evaluate the performance of a combination of processes - inter-ozonization and post-filter GAC adsorbers systems, on the control of organic precursors and disinfection byproducts, especially trihalomethanes (THM). The experience was conducted with filtered water produced at Alto da Boa Vista conventional WTP, located at São Paulo city, where raw water comes from a high eutrofic lake. The experimental setup consists of an ozonation system with four column shaped contactors arranged in series with 16 minutes total hydraulic detention time; and, a system of four pilot scale adsorbers with different types of granular activated carbon (GAC) media, F1 and F3 filters with mineral GAC media (GAC1, bituminous) and F2 and F4 filters with vegetal GAC media (GAC2, coconut shell), all operated in parallel with empty bed contact time (EBCT) between 15 and 20 minutes. Two columns were fed with filtered and pre-ozonated water (F1 and F2) and the other two were fed with filtered water only (F3 and F4). It was observed that ozonation did not affect significantly results of precursors parameters, TOC and UV-254, and neither THM. Initially, TOC removal remained high, near 80% delineating the bed saturation around 240 days to F1 and F3 filters (GAC1) and only 30 days with low efficiency for filters F2 and F4 (GAC2). The THM bed saturation time was nearly 65 days for both media and initial efficiencies were 90% and 75% to GAC1 and GAC2, respectively. With all beds saturated, still there was a good taste and odor producing substances removal. In this work, the systems of GAC adsorbents post-filters were effective for the control of precursors and to reduce the formation of THM\'s, with better results for the CAG1 (bituminous) regardless of the use of inter-ozonization.
15

Enriquecimento geoquímico de metais em testemunhos de sedimentos, correlacionado com granulometria e teores de matéria orgânica / Geochemical enrichment of metals in sediment cores correlated with soil texture and organic matter content

Fernandes, Felippe 21 August 2015 (has links)
O município de Viamão está localizado na região metropolitana de Porto Alegre, no estado do Rio Grande Sul. A barragem Mãe d\'Água foi construída em 1962, com o intuito de atender à demanda da Universidade Federal do Rio Grande do Sul, mais precisamente o Instituto de Pesquisas Hidráulicas, porém, devido à falta de planejamento urbano, durante os últimos quarenta anos, vem acarretando uma diversificada série de passivos ambientais, como contaminantes orgânicos e/ou inorgânicos. Neste seguimento, o presente trabalho busca avaliar as concentrações dos metais Zinco e Níquel, teores de matéria orgânica e a composição granulométrica nas diferentes profundidades amostradas em testemunhos de sedimentos produzidos nesta bacia hidrográfica que compõe a barragem Mãe d\'Água. As coletas de amostras foram realizadas em junho de 2014, sendo amostrados quatro testemunhos sedimentares distribuídos no lago da referida barragem. Para a extração dos testemunhos foi utilizado um amostrador de núcleo \"Piston Core\". Os sedimentos da fração menor que 63μm foram destinados a análise química para verificação da presença e concentração dos elementos traço: Níquel (Ni) e Zinco (Zn). A metodologia de digestão ácida empregada é a EPA 3050, adotada pela U.S. Environment Protection Agency, sendo que as análises foram realizadas em duplicata e, para controle de qualidade, foram utilizados dois materiais de referência da USGS (U.S. Geological Survey): SGR-1b e SCO-1. Com os resultados obtidos, a caracterização granulométrica da sedimentação sob o barramento mostrou-se suscetível a contaminação por metais ao longo nas últimas décadas. Todas as amostras apresentaram concentrações de Zn e Ni acima do valor de background local e com padrões de crescimento, portanto, evidenciam a existência de enriquecimento dos sedimentos por estes elementos. Os teores de matéria orgânica quando correlacionados as concentrações de Zn e Ni evidenciaram o crescente enriquecimento nos testemunhos analisados, confirmando a alta afinidade destes elementos à sedimentos compostos de fração orgânica. O índice de geoacumulação para a maior parte das concentrações dos metais nas diferentes profundidades encontra-se caracterizadas como não poluída. Considerando que a área de estudo se caracteriza historicamente pela ocupação residencial, ações antropogênicas podem ser consideradas as principais provedoras dos passivos ambientais aos corpos d\'água. / The municipality of Viamão is located in the metropolitan region of Porto Alegre, state of Rio Grande do Sul. The Mãe D\'água Dam was built in 1962, so that demands from the Federal University of Rio Grande do Sul, more precisely the Institute of Hydraulic Research could be met. However, due to a lack of urban planning over the past forty years, the dam has caused several environmental liabilities, such as organic contaminants and / or inorganic contaminants. This manuscript addresses an evaluation of the concentrations of the metals zinc and nickel metals, organic matter content and particle size composition at different depths sampled in sediment cores produced in the watershed that comprises Mãe d\'Água. Four sediment core distributed in the dam lake were collected in June 2014, by \"Piston Core\" core sampler. Sediments whose fraction was lower than 63μm were subjected to chemical analyses regarding the presence and concentration of nickel (Ni) and zinc (Zn). The acid digestion methodology employed was EPA 3050, adopted by the US Environment Protection Agency. The analyses were performed in duplicate and two USGS (US Geological Survey) reference materials, namely: SGR-1b and SCO-1 were used for the quality control. The particle size characterization of sedimentation under the bus has proved susceptible to metal contamination over the past decades. All samples showed concentrations of Zn and Ni higher than the local background values and growth patterns, which evidenced an enrichment of sediments. In comparison to the organic matter content, the Zn and Ni concentrations showed a growing enrichment, which confirmed the high affinity of these elements for sediments composed of organic fraction. The geoaccumulation index for most of the metal concentrations at different depths has been characterized as non polluted. As whereas the study area is historically by historically residential occupation, anthropogenic actions can be considered the main causes of environmental damage to water bodies.
16

Estudo da contaminação e da toxicidade do solo do Aterro Metropolitano de Gramacho, Duque de Caxias RJ. / Study of contamination and toxicity of Gramacho metropolitan landfill soil, Duque de Caxias - RJ.

Quézia SantAna da Silva 11 April 2013 (has links)
O Aterro Metropolitano de Gramacho, considerado o maior da América Latina, teve encerradas as suas atividades de disposição de resíduos em meados de 2012. A disposição de resíduos no local foi realizada diretamente sobre o solo de fundação desde o início de sua operação (1978). Considerando-se que os contaminantes presentes no lixiviado podem migrar por difusão através da argila organo-salina do aterro e atingir o entorno, foi feita uma investigação da contaminação do solo no perímetro do aterro. Essa investigação foi realizada no líquido intersticial do solo e foi pautada em dois tipos de contaminantes: nitrogênio amoniacal e compostos orgânicos, medidos pelo parâmetro carbono orgânico total (COT). Além disso, foram também realizados ensaios de toxicidade aguda com a espécie Vibrio fischeri para avaliar a toxicidade no solo. Ensaios de sorção e difusão foram executados a fim de melhor compreender o comportamento dos contaminantes investigados. Os resultados apontaram baixos valores de nitrogênio amoniacal e de COT no solo. Os valores de nitrogênio amoniacal são considerados baixos, pois mesmo em amostras de solo da barreira lateral, que é situada próxima à antiga vala de drenagem de lixiviado, estes são menores que 1% do encontrado no lixiviado, indicando a adsorção do solo. Os ensaios de toxicidade aguda apontaram o efeito Hormesis nas amostras de líquido intersticial, indicando a possibilidade de presença de toxicidade crônica. / The Gramacho Metropolitan Landfill, considered the largest in Latin America, had closed their waste disposal activities in mid 2012. The waste disposal was performed directly on the foundation soil since the beginning of its operation (1978). Considering that the contaminants present in the leachate can migrate by diffusion through the organo-saline clay of the landfill and reaches surroundings, an soil contamination investigation was made at the perimeter of the landfill. This research was conducted in the interstitial liquid of the soil and was based on two types of contaminants: ammoniacal nitrogen and organic recalcitrant compounds, parameter measured by total organic carbon (TOC). Moreover, acute toxicity assays was also performed with the species Vibrio fischeri to assess toxicity in the soil. Sorption and diffusion assays were performed to better understand the behavior of contaminants investigated. The results showed low levels of ammoniacal nitrogen and TOC in the soil. Ammoniacal nitrogen values are surprisingly low, because even in soil samples from the side barrier, which is situated adjacent to the drainage ditch leachate, these are less than 1% that found in leachate, indicating the soil adsorption. The acute toxicity assays showed the effect Hormesis in interstitial liquid samples, indicating the possibility of the presence of chronic toxicity.
17

Estudo da contaminação e da toxicidade do solo do Aterro Metropolitano de Gramacho, Duque de Caxias RJ. / Study of contamination and toxicity of Gramacho metropolitan landfill soil, Duque de Caxias - RJ.

Quézia SantAna da Silva 11 April 2013 (has links)
O Aterro Metropolitano de Gramacho, considerado o maior da América Latina, teve encerradas as suas atividades de disposição de resíduos em meados de 2012. A disposição de resíduos no local foi realizada diretamente sobre o solo de fundação desde o início de sua operação (1978). Considerando-se que os contaminantes presentes no lixiviado podem migrar por difusão através da argila organo-salina do aterro e atingir o entorno, foi feita uma investigação da contaminação do solo no perímetro do aterro. Essa investigação foi realizada no líquido intersticial do solo e foi pautada em dois tipos de contaminantes: nitrogênio amoniacal e compostos orgânicos, medidos pelo parâmetro carbono orgânico total (COT). Além disso, foram também realizados ensaios de toxicidade aguda com a espécie Vibrio fischeri para avaliar a toxicidade no solo. Ensaios de sorção e difusão foram executados a fim de melhor compreender o comportamento dos contaminantes investigados. Os resultados apontaram baixos valores de nitrogênio amoniacal e de COT no solo. Os valores de nitrogênio amoniacal são considerados baixos, pois mesmo em amostras de solo da barreira lateral, que é situada próxima à antiga vala de drenagem de lixiviado, estes são menores que 1% do encontrado no lixiviado, indicando a adsorção do solo. Os ensaios de toxicidade aguda apontaram o efeito Hormesis nas amostras de líquido intersticial, indicando a possibilidade de presença de toxicidade crônica. / The Gramacho Metropolitan Landfill, considered the largest in Latin America, had closed their waste disposal activities in mid 2012. The waste disposal was performed directly on the foundation soil since the beginning of its operation (1978). Considering that the contaminants present in the leachate can migrate by diffusion through the organo-saline clay of the landfill and reaches surroundings, an soil contamination investigation was made at the perimeter of the landfill. This research was conducted in the interstitial liquid of the soil and was based on two types of contaminants: ammoniacal nitrogen and organic recalcitrant compounds, parameter measured by total organic carbon (TOC). Moreover, acute toxicity assays was also performed with the species Vibrio fischeri to assess toxicity in the soil. Sorption and diffusion assays were performed to better understand the behavior of contaminants investigated. The results showed low levels of ammoniacal nitrogen and TOC in the soil. Ammoniacal nitrogen values are surprisingly low, because even in soil samples from the side barrier, which is situated adjacent to the drainage ditch leachate, these are less than 1% that found in leachate, indicating the soil adsorption. The acute toxicity assays showed the effect Hormesis in interstitial liquid samples, indicating the possibility of the presence of chronic toxicity.
18

Enriquecimento geoquímico de metais em testemunhos de sedimentos, correlacionado com granulometria e teores de matéria orgânica / Geochemical enrichment of metals in sediment cores correlated with soil texture and organic matter content

Felippe Fernandes 21 August 2015 (has links)
O município de Viamão está localizado na região metropolitana de Porto Alegre, no estado do Rio Grande Sul. A barragem Mãe d\'Água foi construída em 1962, com o intuito de atender à demanda da Universidade Federal do Rio Grande do Sul, mais precisamente o Instituto de Pesquisas Hidráulicas, porém, devido à falta de planejamento urbano, durante os últimos quarenta anos, vem acarretando uma diversificada série de passivos ambientais, como contaminantes orgânicos e/ou inorgânicos. Neste seguimento, o presente trabalho busca avaliar as concentrações dos metais Zinco e Níquel, teores de matéria orgânica e a composição granulométrica nas diferentes profundidades amostradas em testemunhos de sedimentos produzidos nesta bacia hidrográfica que compõe a barragem Mãe d\'Água. As coletas de amostras foram realizadas em junho de 2014, sendo amostrados quatro testemunhos sedimentares distribuídos no lago da referida barragem. Para a extração dos testemunhos foi utilizado um amostrador de núcleo \"Piston Core\". Os sedimentos da fração menor que 63μm foram destinados a análise química para verificação da presença e concentração dos elementos traço: Níquel (Ni) e Zinco (Zn). A metodologia de digestão ácida empregada é a EPA 3050, adotada pela U.S. Environment Protection Agency, sendo que as análises foram realizadas em duplicata e, para controle de qualidade, foram utilizados dois materiais de referência da USGS (U.S. Geological Survey): SGR-1b e SCO-1. Com os resultados obtidos, a caracterização granulométrica da sedimentação sob o barramento mostrou-se suscetível a contaminação por metais ao longo nas últimas décadas. Todas as amostras apresentaram concentrações de Zn e Ni acima do valor de background local e com padrões de crescimento, portanto, evidenciam a existência de enriquecimento dos sedimentos por estes elementos. Os teores de matéria orgânica quando correlacionados as concentrações de Zn e Ni evidenciaram o crescente enriquecimento nos testemunhos analisados, confirmando a alta afinidade destes elementos à sedimentos compostos de fração orgânica. O índice de geoacumulação para a maior parte das concentrações dos metais nas diferentes profundidades encontra-se caracterizadas como não poluída. Considerando que a área de estudo se caracteriza historicamente pela ocupação residencial, ações antropogênicas podem ser consideradas as principais provedoras dos passivos ambientais aos corpos d\'água. / The municipality of Viamão is located in the metropolitan region of Porto Alegre, state of Rio Grande do Sul. The Mãe D\'água Dam was built in 1962, so that demands from the Federal University of Rio Grande do Sul, more precisely the Institute of Hydraulic Research could be met. However, due to a lack of urban planning over the past forty years, the dam has caused several environmental liabilities, such as organic contaminants and / or inorganic contaminants. This manuscript addresses an evaluation of the concentrations of the metals zinc and nickel metals, organic matter content and particle size composition at different depths sampled in sediment cores produced in the watershed that comprises Mãe d\'Água. Four sediment core distributed in the dam lake were collected in June 2014, by \"Piston Core\" core sampler. Sediments whose fraction was lower than 63μm were subjected to chemical analyses regarding the presence and concentration of nickel (Ni) and zinc (Zn). The acid digestion methodology employed was EPA 3050, adopted by the US Environment Protection Agency. The analyses were performed in duplicate and two USGS (US Geological Survey) reference materials, namely: SGR-1b and SCO-1 were used for the quality control. The particle size characterization of sedimentation under the bus has proved susceptible to metal contamination over the past decades. All samples showed concentrations of Zn and Ni higher than the local background values and growth patterns, which evidenced an enrichment of sediments. In comparison to the organic matter content, the Zn and Ni concentrations showed a growing enrichment, which confirmed the high affinity of these elements for sediments composed of organic fraction. The geoaccumulation index for most of the metal concentrations at different depths has been characterized as non polluted. As whereas the study area is historically by historically residential occupation, anthropogenic actions can be considered the main causes of environmental damage to water bodies.
19

Avaliação da disponibilidade potencial e toxicidade de metais-traço em sedimentos superficiais da região da Ilha da Madeira, Baía de Sepetiba, RJ

Rodrigues, Sarah Karoline 03 May 2016 (has links)
Submitted by Biblioteca de Pós-Graduação em Geoquímica BGQ (bgq@ndc.uff.br) on 2016-05-03T17:55:19Z No. of bitstreams: 1 Dissertação_Sarah_K._Rodrigues (final).pdf: 2191755 bytes, checksum: 7bb012b5c768c4bc50d38c29d71f34a2 (MD5) / Made available in DSpace on 2016-05-03T17:55:19Z (GMT). No. of bitstreams: 1 Dissertação_Sarah_K._Rodrigues (final).pdf: 2191755 bytes, checksum: 7bb012b5c768c4bc50d38c29d71f34a2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Universidade Federal Fluminense. Instituto de Química. Programa de Pós-Graduação em Geociências-Geoquímica. Niterói, RJ / Testes de toxicidade são ferramentas frequentemente empregadas para avaliações da qualidade de ecossistemas e identificar áreas sensíveis. Para avaliar a qualidade dos sedimentos da região da Ilha da Madeira (Baía de Sepetiba), área considerada sob impacto de passivos da Ingá, realizou-se caracterização granulométrica, análises do fracionamento geoquímico de metais-traço, determinação das concentrações de acid-volatile sulfides (AVS) e carbono orgânico total (COT) e testes de toxicidade aguda e crônica de sedimento integral, em amostras de cinco pontos do local. O ensaio agudo com o Tiburonella viscana (anfípoda) apresentou toxicidade apenas para a desembocadura do canal do Saco do Engenho e os testes com Tisbe biminiensis (copépode) indicaram diferença significativa com o controle, apresentando baixas taxas de fecundidade, em todos os pontos. Os níveis de metais-traço na região do Saco do Engenho representam um alerta principalmente para Cd e Zn que atingiram concentrações duas ordens de grandeza maiores que os valores orientadores da Resolução CONAMA 454/2012. A utilização de normalizadores como o AVS e o COT para a estimativa de fases complexantes capazes de se associar aos metais-traço, que podem estar presentes na água intersticial, demonstrou que nos pontos na região de Coroa Grande, Porto de Itaguaí e Ilha de Itacuruçá há teores suficientes de AVS e COT para aprisionar os metais-traço na fase sólida dos sedimentos. Entretanto, os resultados apresentados não possuem relações diretas com a toxicidade encontrada, uma vez que as rotas de exposição dos organismos empregados incluem também a via oral. Os resultados demonstram a importância da integração de estudos de toxicidade com as ferramentas geoquímicas para uma avaliação mais consistente da qualidade ambiental em sistemas costeiros, como a região da Ilha da Madeira, na Baía de Sepetiba / Toxicity tests are tools frequently employed to evaluate the quality of ecosystems and to identify vulnerable regions. In order to evaluate the sediment conditions in the Madeira Island area (Sepetiba Bay), the region under the influence of Ingá Cia. metallurgical wastes, was held sediments characterization throught fractionation of trace metals, grain size analisys, total organic carbon (TOC) and AVS (acid volatile sulfide) and sediment integral acute and chronic toxicity tests in samples from five sites. The acute test with Tiburonella viscana (amphipod) showed toxicity only at the Saco do Engenho inlet mouth and Tisbe biminiensis (copepod) low fertility rates responsefor all sites. Trace metals concentrations at Saco do Engenho inlet mouth represent a special concern for Cd and Zn, which both showed levels at two orders of magnitude higher than the values suggests by CONAMA 454/2012 Brazilian Resolution guideline for dredge materials disposal. The use of normalizing as AVS and TOC to estimate complexing phases which are able to associate with trace metals, that may be present in the pore water, showedthe sites in the region of Coroa Grande, Itaguaí harbor and Itacuruçá island exhibit values for ΣSEM/AVS under 1 and -100 μmol g OC−1for ΣSEM-AVS/ƒOC, i.e., there is levels of AVS and TOC able to trapping trace metals in solid phases. However, the results do not show a direct relationship with toxicity, since the exposure routes for theorganisms employees are dermal and oral. Although, thelines of evidence not present direct relationships, but they can give an overview on the sediment toxic situation. The results demonstrate the importance of studies integrating toxicity with other tools for a more efficient environmental quality assessment in estuarine systems, such as the region of Madeira Island, in Sepetiba Bay
20

Frações físicas e qualidade da matéria orgânica em agroecossistemas do Bioma Pampa. / Fractions and physical quality of organic matter in agroecosystems of the Pampa Biome.

Santos, Daiane Carvalho dos 18 March 2011 (has links)
Made available in DSpace on 2014-08-20T14:37:00Z (GMT). No. of bitstreams: 1 Tese_Daiane_Carvalho_dos_Santos.pdf: 3060772 bytes, checksum: 73cb01bf57d8c16320b8d8d43cdc6255 (MD5) Previous issue date: 2011-03-18 / Few studies evaluate the dynamics and quality of soil organic matter (OM) in agroecosystems of the Pampa Biome. Conservation tillage systems based on the reduction of tillage operations and addition of crop residues, contribute to maintaining and improving soil quality and the environment. In this work, the studies 1 and 2 are related to evaluation of physical fractions of organic matter from the point of view of quantity and quality in the whole soil and in aggregates under areas arenizadas in the southwest of RS, This studies was done in an Paleudult under cultivation of eucalyptus forest homogeneous (FH) system agrosilvopasture (SA) and native (CN). The studies 3 and 4 aimed evaluating quantitatively and qualitatively the physical fractions of organic matter in whole soil and in aggregate in an Albaqualf under cultivation of ryegrass (Lollium multiflorum Lam) + birdsfoot trefoil (Lotus corniculatus), as cover crops in winter and rotation soybean (Glycine max L.) / maize (Zea mays L.) / sorghum (Sorghum vulgare) in the summer in conventional tillage (CT) and no-tillage (NT). As reference area, was sampled an native area (CN). For both studies, soil was collected in the layers from 0.000 to 0.025m and 0.025 to 0.075m depth. The soil was air-dried and sieved at 8.00mm mesh and in aggregate classes (8.00 to 4.76, 4.76 - 2.00, 2.00 to 1.00, 1.00 to 0.50, 0.50 to 0.25 and <0.25mm). The stocks were determined from total organic carbon (TOC) in layers from 0.000 to 0.025m and 0.025 to 0.075m. The physical fractionation and granulometric densimetric SOM were realized to obtain the coarse fraction (CGC), carbon associated with minerals (CAM), free light fraction (FLF), occluded light fraction (OLF) and heavy fraction (HF). The first one study it was concluded that cultivation of FH in sandy soils caused increase in the stock of TOC, total nitrogen (TN) in the soil and fractions CFG, CAM, FLF and OLF when compared to CN in the surface layer. The SA in the soil samples showed more humified OM compared to CN and FH. The OLF, physically protected within the soil aggregates, presented higher proportion of more recalcitrant compounds in relation to FLF. In study 2 concluded that the FH showed the highest values of TOC accumulated in the layer from 0.000 to 0.075m depth in classes of 8.00 to 1.00mm and for the CFG and CAM in theclasses 8.00 to 0,50mm. The FLF was sensitive to changes in land use in the aggregates from 8.00 to 4.76mm at depths from 0.000 to 0.025m 0.025 to 0.075m, and these increments to the FH and CN, respectively. For all systems evaluated (FH, SA and CN), the degree of humification was higher in smaller diameter classes (0.50 - <0.25mm). The OLF showed higher free radical semiquinone, indicating humification. It was concluded from the study 3 that the NT in lowland soils increases the stock of CFG and FLF in comparison to the CT. This effect was restricted to the superficial layer, and these fractions were more sensitive than the TOC to changes in land management. In four years of experiment, te management systems had no effect on the stock of CAM and HF. By Laser Induced Fluorescence (LIF), under CT soil samples showed humified OM compared to the NT and CN. The FLF had a higher proportion of more labile compounds in relation to the OLF. In the study 4 it was concluded that the management systems under CT and NT in lowlands, reduced TOC, FLF and OLF in the aggregates of 4.76 to <0.25mm and a CFG in the classes 12 of 2.00 to <0.25mm compared to CN. Increases in stock of the FLF under NT were obtained in aggregates from 0.50 to <0.25mm in the layer from 0.000 to 0.025m for 0.000 to 0.075m, compared with CT. The largest stock of OLF in the surface layer was observed under NT in the class of the aggregates of 8.00 to 4.76mm. The increases in HF were obtained under the CT. The highest TOC, CGC, CAM, OLF and HF for the CT and NT were found in the classes of larger size aggregates (8.00 to 2.00mm), while a reduction in these stocks declined as the size of aggregates. Through the LIF and the EPR, the humification degree of OM increased with decreased the aggregate classes. / Escassos são os estudos que avaliam a dinâmica e a qualidade da matéria orgânica (MO) do solo em agroecossistemas do Bioma Pampa. Sistemas conservacionistas de manejo baseados na redução das operações de preparo do solo e na elevada e contínua adição de resíduos culturais, contribuem para a manutenção e melhoria da qualidade do solo e do ambiente. Neste trabalho, desenvolveram-se os seguintes estudos: os estudos 1 e 2 estão relacionados à avaliação das frações físicas da MO sob o ponto de vista quantitativo e qualitativo no solo inteiro e em classes de agregados, em áreas arenizadas do Sudoeste do estado do Rio Grande do Sul, em um Argissolo Vermelho sob cultivo de floresta homogênea de eucalipto (FH), sistema agrosilvipastoril (SA) e campo nativo (CN); os estudos 3 e 4 objetivaram avaliar quantitativamente e qualitativamente as frações físicas da MO no solo inteiro e em classes de agregados porém, em um Planossolo Háplico, sob cultivo de azevém (Lollium multiflorum Lam) + cornichão (Lotus corniculatus), como culturas de cobertura no inverno e rotação soja (Glycine Max L.)/milho (Zea mays L.)/sorgo (Sorghum vulgare) no verão em preparo convencional (PC) e plantio direto (PD). Como área de referência, amostrou-se uma área sob campo nativo (CN). Para ambos os estudos, o solo foi coletado nas camadas de 0,000 0,025m e de 0,025 0,075m seco ao ar e peneirado em malha de 8,00mm e em classes de agregados (8,00 4,76, 4,76 2,00, 2,00 1,00, 1,00 0,50, 0,50 0,25 e <0,25mm). Foram avaliados os estoques de carbono orgânico total (COT) e realizado o fracionamento físico granulométrico e densimétrico da MO para obtenção do carbono da fração grosseira (CFG), carbono associado aos minerais (CAM), fração leve livre (FLL), fração leve oclusa (FLO) e fração pesada (FP). No estudo 1 concluíu-se que o cultivo de homogêneo de eucalipto (FH) promoveu o aumento do estoque de COT, NT no solo e nas frações CFG, CAM, FLL e FLO quando comparado ao CN na camada superficial. No SA as amostras de solo apresentaram MO mais humificada quando comparada ao CN e a FH. A FLO, protegida fisicamente no interior dos agregados do solo, apresentou maior proporção de compostos mais recalcitrantes em relação à FLL. No estudo 2 concluíu-se que a FH promoveu os maiores estoques de COT acumulados na camada de 0,000 a 0,075m nas classes de 8,00 a 1,00mm e para o CFG e CAM nas classes que compreendem de 8,00 a 0,50mm. A FLL mostrou-se sensível as mudanças de uso do solo na classe de agregados de 8,00 4,76mm, nas camadas estudadas. Para todos os sistemas de uso avaliados, o grau de humificação foi maior nas classes de menor diâmetro (0,50 a <0,25mm). Concluiu-se pelo estudo 3 que o o PD aumenta os estoques de CFG e de FLL em comparação ao PC, sendo este efeito restrito à camada superficial em curto prazo (quatro anos), neste período, os sistemas de manejo não afetaram o CAM e a FP. O mecanismo mais importante de proteção e estabilização da MO é a interação organomineral, seguido da oclusão e a recalcitrância química. Sob PC as amostras de solo apresentaram MO mais humificada quando comparado ao PD e CN. A FLL apresentou maior proporção de compostos mais lábeis em relação à FLO. No estudo 4 concluíu-se que o PC e o PD em agroecossistema de terras baixas, reduziram os estoques de COT, FLL e FLO 10 nas classes de agregados 4,76 a <0,25mm e de CFG nas classes de 2,00 a <0,25mm quando comparado ao CN. Incrementos no estoque de FLL sob PD foram obtidos nas classes de agregados de 0,50 a <0,25mm, na camada de 0,000 0,025m e para o acumulado de 0,000 a 0,075m, quando comparado a PC. Maior estoque de FLO na camada superficial foi verificado sob PD na classe e agregados de 8,00 4,76mm. O PC contribuiu para o incremento relativo na PF da MO. Os maiores estoques de COT, CFG, CAM, FLO e FP para o PC e o PD, foram encontrados nas classes de agregados de maior tamanho. O grau de humificação da MO aumentou com a redução do diâmetro dos agregados.

Page generated in 0.0183 seconds