91

Por uma moradia termicamente confort?vel: proposta de habita??o de interesse social com ?nfase no conforto t?rmico

Monteiro, Verner Max Liger de Mello 14 April 2012 (has links)
Made available in DSpace on 2014-12-17T13:57:06Z (GMT). No. of bitstreams: 1 VernerMLMM_DISSERT_Vol 1_1-127.pdf: 2966861 bytes, checksum: 185597d8ebd12bf8bea8e39f542cf0f1 (MD5) Previous issue date: 2012-04-14 / This research covers the topic of social housing and its relation to thermal comfort, so applied to an architectural and urban intervention in land situated in central urban area of Maca?ba/RN, Brazil. Reflecting on the role of design and use of alternative building materials in the search for better performance is one of its main goals. The hypothesis is that by changing design parameters and choice of materials, it is possible to achieve better thermal performance results. Thus, we performed computer simulations of thermal performance and natural ventilation using computational fluid dynamics or CFD (Computational Fluid Dynamics). The presentation of the thermal simulation followed the methodology proposed in the dissertation Negreiros (2010), which aims to find the percentage of the amount of hours of comfort obtained throughout the year, while data analysis was made of natural ventilation from images generated by the images extracted from the CFD. From model building designed, was fitted an analytical framework that results in a comparison between three different proposals for dwellings housing model, which is evaluated the question of the thermal performance of buildings, and also deals with the spatial variables design, construction materials and costs. It is concluded that the final report confirmed the general hypotheses set at the start of the study, it was possible to quantify the results and identify the importance of design and construction materials are equivalent, and that, if combined, lead to gains in thermal performance potential. / Esta pesquisa abrange a tem?tica da habita??o de interesse social e sua rela??o com o conforto t?rmico, de forma aplicada a uma interven??o urban?stica e arquitet?nica em terreno situado na regi?o central da zona urbana de Maca?ba/RN. Refletir sobre o papel do projeto e da utiliza??o de materiais construtivos alternativos na busca por melhores resultados de desempenho ? um dos seus principais objetivos. A hip?tese ? que, atrav?s da mudan?a de par?metros de projeto e de escolha de materiais, ? poss?vel obter melhores resultados de desempenho t?rmico, sem ultrapassar os limites or?ament?rios impostos pelos programas habitacionais. Para tanto, foram realizadas simula??es computacionais de desempenho t?rmico e de ventila??o natural atrav?s de din?mica dos fluidos computacional ou CFD (Computacional Fluid Dynamics). A apresenta??o dos dados de simula??o t?rmica seguiu a metodologia proposta na disserta??o de Negreiros (2010), que visa encontrar o percentual da quantidade de horas de conforto obtidas em todo o ano, enquanto que a an?lise dos dados de ventila??o natural foi feita a partir das imagens geradas pelas imagens extra?das do CFD. A partir do modelo de edifica??o projetado, foi montado um quadro anal?tico que tem como resultado um comparativo entre tr?s diferentes propostas de habita??es modelo de conjuntos habitacionais, no qual ? avaliada a quest?o do desempenho t?rmico das edifica??es, e tamb?m s?o abordadas as vari?veis espaciais de projeto, materiais construtivos e custos. Conclui-se que o trabalho final confirmou as hip?teses gerais estabelecidas no in?cio da pesquisa, tendo sido poss?vel quantificar os resultados e identificar que a import?ncia do projeto e dos materiais construtivos s?o equivalentes, e que, se somados, levam a ganhos de desempenho t?rmico em potencial.
92

Avaliação do ambiente e da eficacia de sistemas de climatização para a produção industrial de perus / Evaluation of the environment and the efficiency of acclimatization systems for the industrial turkey production

Mendes, Angelica Signor 18 December 2007 (has links)
Orientadores: Daniella Jorge de Moura, Irenilza de Alencar Naas / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-10T15:53:47Z (GMT). No. of bitstreams: 1 Mendes_AngelicaSignor_D.pdf: 2662314 bytes, checksum: 4bb4c20870de3ad74f332028edd8764f (MD5) Previous issue date: 2007 / Resumo: O objetivo principal deste estudo foi a avaliação do impacto das combinações das variáveis bioclimáticas temperatura, velocidade e umidade relativa do ar na produção de perus, e avaliar a eficácia de dois sistemas de ventilação mínima (positiva e negativa) para a fase inicial (1 ¿ 28 dias) e de três sistemas de climatização (ventilação positiva I, ventilação positiva II e ventilação negativa) para a fase final de criação de perus (4 - 20 semanas). Os aviários situados no município de Francisco Beltrão, Paraná, para o estudo da fase inicial de criação dos perus, foram comparados sob os parâmetros de concentrações de dióxido de carbono (CO2), temperatura e umidade relativa do ar e índices produtivos. Os aviários situados no município de Uberlândia, Minas Gerais, para o estudo da fase final de criação dos perus, foram comparados sob os parâmetros de concentrações de CO2, temperatura e umidade relativa do ar, iluminância, temperatura superficial da cama e índices produtivos. Os resultados mostraram que as concentrações de CO2 no ar estiveram abaixo dos limites máximos recomendados internacionalmente para a fase final de criação, e no limite para a fase inicial, para todos os sistemas. As temperaturas internas para ambos os sistemas de ventilação avaliados para a fase inicial de criação permaneceram dentro zona de conforto das aves e os níveis de umidade relativa do ar estiveram, em média, na faixa recomendada. Na fase final, as temperaturas internas para ambos os sistemas de climatização avaliados estiveram sempre acima do recomendado para as aves, e os níveis de umidade relativa do ar estiveram, em média, na faixa recomendada, para todos os sistemas. Conclui-se, para a fase inicial e final de criação, que o sistema de ventilação mínima positiva e túnel negativo forneceram um melhor ambiente térmico às aves, respectivamente. Para a fase final, não encontrou-se variações suficientes entre os sistemas de ventilação positiva I e II, que permitissem a escolha entre esses dois sistemas / Abstract: This research aimed to evaluate the impact of the combination of bioclimatic variables such as: temperature, wind velocity and relative humidity in turkey production, as well as the efficiency of two minimum ventilation systems (positive and negative) for the initial phase ( 1 . 28 days), and three acclimatization systems (positive ventilation I, positive ventilation II and negative ventilation) for the final turkey growing stage ( 4 . 20 weeks). The turkey housing was placed at Francisco Beltrão country, Paraná state, used in the initial stage of production there were compared the following parameters: CO2 concentration, both ambient temperature and relative humidity, and production index. In the houses located in the country of Uberlândia, Minas Gerais state, used in the final stage of production the following data were compared: CO2 concentration, both ambient temperature and relative humidity, light intensity and production index. It was concluded that air CO2 concentration was below the maximum internationally recommended limits for both stages of growth. The ambient temperatures for both ventilation systems evaluated in the initial phase remained within the thermal comfort zone, and the relative humidity was also whit the recommended limits. For the final growing stage the ambient temperature in both evaluated acclimatization systems were above the recommended for the birds, and the mean air relative humidity results were also within the limits. It was concluded that for the initial and final growing stage the minimum positive ventilation system and the negative tunnel ventilation system respectively provided better thermal environment for the birds. For the final growing stage was not possible to choice the best one between the positive ventilation systems I and II / Doutorado / Construções Rurais e Ambiencia / Doutor em Engenharia Agrícola
93

Metodologia de aperfeiçoamento de suspensões veiculares através de modelo virtual em ambiente multicorpos / Improvement methodology of vehicle suspensions through model in virtual environment multibody

Alaor Jose Vieira Neto 19 April 2011 (has links)
Entre as etapas do desenvolvimento de automóveis pode-se apontar a definição das características de suas suspensões. A fase de definição da suspensão pode ser dividida dentro do seguinte cenário: a escolha de um determinado tipo de suspensão, os pontos (geometria) e quais os valores de rigidez/amortecimento para todo o sistema irá resultar em um comportamento dinâmico desejado para o veículo, bem como a viabilidade de produção. Além disso, o entendimento da interação entre os parâmetros de suspensão, é crucial para a otimização do desempenho. Este trabalho pretende propor um método para aperfeiçoar a fase de \"tuning\" da suspensão, com foco principal no conforto. O veículo considerado é um caminhão comercial, e entre os seus parâmetros considerados estão rigidezes de molas da cabine e suspensão, amortecimento da suspensão de cabine e curvas do amortecedor da suspensão primária. O modelo virtual do veículo foi desenvolvido em ambiente ADAMS, o qual, previamente à otimização, foi validado contra dados experimentais. Métricas foram especialmente desenvolvidas levando em consideração aspectos subjetivos de conforto veicular, para dessa forma eliminar a variabilidade entre as avaliações subjetivas e análises das simulações. Os resultados mostraram expressivas melhorias no conforto e através de dados experimentais essas melhorias foram confirmadas. / Among the development phases of an automotive vehicle one can point out the definition of the characteristics of its suspensions. Suspension definition phase can be understood as the following scenario: given a suspension type, which hard points (geometric) and what values of stiffness/damping for the whole system will result in a desired dynamic behavior for the vehicle as well as production feasibility. Moreover, understanding the iteration among the suspension parameters, even considering just the tuning ones, is crucial for performance optimization. This work intends to propose a method for vehicle tuning characteristics optimization, having as a target the ride comfort. The vehicle considered here is a commercial truck, and among its parameters one considers cabin and suspension springs, cabin dampers and suspension damper curves. A vehicle model was developed in ADAMS environment and prior to the optimization the vehicle was validated against experimental data. Metrics were specially developed to take into account subjective aspects of ride, and, in this way, eliminating the gap between subjective evaluations and simulations analysis. Results showed improvements in ride comfort. The resulting setup was measured and the improvements were confirmed with experimental data.
94

Utilização de exaustores eólicos no controle da temperatura e da ventilação em ambiente protegido. / The use of rotary turbine ventilator for controlling the air temperature and ventilation in greenhouse.

René Porfirio Camponez do Brasil 21 December 2004 (has links)
O objetivo geral desse trabalho foi o de avaliar a utilização de exaustores eólicos no controle da temperatura e da ventilação no interior do ambiente protegido. Esse trabalho foi realizado em dois ambientes protegidos na área experimental do Departamento de Engenharia Rural, da escola Superior de Agricultura “Luiz de Queiroz”, da Universidade de São Paulo em Piracicaba, SP. Os ambientes protegidos estão instalados no sentido leste-oeste, com dimensões de 6,4m de largura por 17,5m de comprimento, sendo que, em um deles foram instalados três exaustores eólicos na cobertura. A avaliação da distribuição espacial da temperatura do ar (em graus centígrados) no interior dos ambientes protegidos foi realizada através da medição com termopares (cobre-constantã) instalados formando malhas, com espaçamento entre eles de 3,0m e nas alturas de 0,5m, 1,0m, 2,0m 3,0m e 4,0m em relação ao solo, constituindo um conjunto de 78 pontos de amostragem, e os valores de temperatura coletados foram armazenados em um sistema de aquisição de dados. A utilização de exaustores eólicos em ambientes protegidos, apesar de não reduzir significativamente a temperatura do ar nos períodos diurnos, mostrou-se eficaz no controle das temperaturas do ar, melhorando a sua distribuição tanto no perfil vertical como no horizontal, deixando-a uniforme, principalmente na altura da abertura das cortinas. No período noturno, principalmente nas noites de temperaturas mais baixas, manteve as temperaturas internas superiores ao outro ambiente protegido, e ao ambiente externo em até 4°C. A combinação do manejo de cortinas e do uso de exaustores eólicos auxiliados por motor, para utilização nos momentos de aumento de temperatura ou falta de ventos, podem contribuir na redução da temperatura. A utilização dos exaustores eólicos melhora o controle da ventilação otimizando o “efeito termo sifão” ou processo convectivo, através do manejo adequado das cortinas, independente da direção e velocidade dos ventos. A taxa de ventilação do ambiente protegido no experimento com os exaustores movimentados apenas pelo vento foi de 0 a 5 trocas por hora, enquanto que, utilizando os motores auxiliares a taxa foi de 9 a 11 trocas por hora.A análise da distribuição da temperatura do ar por meio de isotermas permitiu uma visão global instantânea dos efeitos do uso de exaustores eólicos retirando a massa de ar quente instalada próxima à cobertura do ambiente protegido, na melhora da distribuição de temperatura do ar, tornando-a mais uniforme e homogênea. / The objective of this study was to evaluate the use of rotary turbine ventilators on the control of air temperature and ventilation in a plastic greenhouse. The experiment was carried out in two plastic greenhouses disposed on East-West direction at the Department of Rural Engineering of College of Agriculture Luiz de Queiroz, University of São Paulo, Piracicaba, São Paulo State. The plastic greenhouses had a dimension of 6.4m width and 17.5m of length being one of them with three of rotary turbine ventilators on roof. The air temperature (°C) spatial distribution was measured using 78 thermocouples (copper-constant) installed in a grid of 3.0m horizontally and five different high, 0.5, 1.0, 2.0, 3.0 and 4.0m from soil surface. The thermocouples were connected to a data logger system and the data were stored. Although the use of rotary turbine ventilator did not decrease the air temperature significantly in diurnal periods, they were efficient in control the air temperature by improving its distribution in horizontal and vertical profile, by keeping uniform, especially at the height of opened curtains. During the night periods, especially under low temperatures, they kept the internal air temperature above another greenhouse and environmental in almost 4°C. The combination of curtains management and rotary turbine motor assisted ventilators can be used for decrease air temperature in moments of high temperature and without winds. The use of rotary turbine ventilators with curtains management improves the ventilation control by performing the convective process, independently of direction and velocity of the wind. Ventilation rate in greenhouse experiment with rotary turbine ventilators moved only by wind ranged from 0 to 5 changes per hour, whereas when assisted by motor system the ventilation rate ranged from 9 to 11 changes per hour. The analysis of air temperature distribution by isotherms lines allowed a global prompt vision of use of rotary turbine ventilators on removing the hot air mass near to the greenhouse roof and improving the distribution of air temperature that became more uniform and homogeneous.
95

Respuesta térmica de edificaciones con envolventes vegetales: cubiertas verdes y fachadas verdes / Thermal response in buildings with green covers: green roofs and green facades

Nuria Pérez Gallardo 16 March 2017 (has links)
El presente proyecto propuso un método experimental de medición de temperaturas internas con el fin de estudiar, comparar y entender la respuesta térmica frente al frío y al calor de cuatro células de ensayo denominadas Control (Sin vegetación) y tres células de ensayo con diferentes combinaciones de vegetación (cubiertas y fachadas) instaladas en una región de clima tropical. En ellas fueron medidas las temperaturas superficiales internas (TSI) y temperaturas del Bulbo Seco (TBS) mediante equipos específicos, un data logger, conectado a dos multiplicadores. Los datos fueron recogidos por un año y dentro de ese periodo fueron seleccionados los días críticos a estudiar. Varios datos climatológicos fueron considerados para abordar la influencia de las oscilaciones del tiempo meteorológico (episodios climáticos) en el ambiente interno construido, para lo cual fueron aplicados fundamentos de la Climatología Dinámica frente al comportamiento térmico de las células de ensayo. Los datos de las principales variables climáticas (radiación solar, humedad relativa y precipitación) fueron registradas en la Estación Meteorológica del CRHEA. Los resultados revelan que la célula de ensayo con vegetación en cubierta y fachadas, presenta más resistencia a las variaciones de temperaturas diarias, es decir, mejor comportamiento térmico, ya que muestra las menores amplitudes térmicas, los mayores retrasos térmicos, las menores temperaturas en días de calor extremo y las mayores en días de frío. Durante el día crítico de calor, las mayores diferencias entre las temperaturas máximas internas del aire, se presentan entre la célula construida con materiales convenciones y la célula que posee fachadas verdes y cubierta vegetal, de 2ºC y en torno a 3ºC en el caso de las temperaturas superficiales. Para el día crítico de frío, la diferencia entre ellas es de 1ºC para los valores de temperatura del aire, y de 2.2ºC para valores de temperaturas superficiales. Así, uso de vegetación en los edificios puede ser considerado una técnica capaz de mantener las condiciones internas más placenteras no solo en épocas calurosas, reduciendo la incidencia de la radiación solar directa, sino también en invierno, debido a su propiedad de aislante térmico que impide las rápidas pérdidas de calor, como ocurre en la célula sin vegetación. Los resultados obtenidos ponen de manifiesto que las hipótesis planteadas fueron alcanzadas, comprobando así, que el uso de vegetación combinado en fachadas y cubiertas contribuye a la mejora del comportamiento térmico, favoreciendo las condiciones térmicas internas en periodos de mayor o menor temperatura externa. / The present research proposed an experimental method for measuring internal temperatures of buildings, in order to study, compare, and understand the thermal response of four test cells against cold and heat, determined: control (without vegetation) and three test cells with different combinations of vegetation (on roofs and/or facades); installed in a tropical climate region. Internal surface temperatures (IST) and dry bulb temperatures (DBT) were measured using appropriate equipment, consisting of a data logger connected to two multipliers. Data were collected for one year and, during that period, the critical days that would be assessed were selected. Climatic data were considered in order to evaluate the influence of weather oscillations (climatic events) on the internal built environment, for which the principles of Dynamic Climatology were applied to understand the thermal behaviour of the test cells. The data obtained from the primary climatic variables (solar radiation, relative humidity, and precipitation) were recorded at the CRHEA. The results showed that the test cell with a green roof and green facades displayed higher resistance to changes in daily temperature, i.e., better thermal behavior, since it faced lower temperature intervals, higher thermal delays, lower temperatures on days of extreme heat, and higher temperatures on cold days. With respect to the critical heat day, the main differences between maximum internal air temperatures occurred between the cell constructed with conventional material and the cell that was built with green facades and a green roof, of 2°C in relation to the internal air temperature, and approximately 3°C with respect to surface temperatures. Regarding the critical cold day, the difference between test cells was of 1°C for air temperature values, and 2.2°C for surface temperature values. Therefore, the use of vegetation in construction can be considered a technique capable of maintaining the most pleasant indoor conditions, not only in hot climates, reducing the incidence of direct solar radiation, but also in the winter, due to thermal insulation properties that prevent the rapid loss of heat, which occurs in cells lacking vegetation. The obtained results show that the initial hypotheses were proven, thus confirming that the application of vegetation on facades and roofs contributes to the improvement of thermal performance, favoring internal thermal conditions during periods of higher or lower external temperatures.
96

Modélisation et optimisation de l’assise d’un fauteuil roulant pour handicapé afin d’améliorer le confort d’un point de vue médical / Modeling and optimization of the wheelchair cushion for handicapped to improve the comfort and prevention pressure ulcers from a medical point of view.

Bui, He Thong 17 January 2018 (has links)
Ma thèse a pour objectifs d’étudier et d’améliorer le confort d’un coussin d’assise dans le cas d’un fauteuil roulant pour handicapé, afin de limiter au mieux, l’apparition des escarres.Mes travaux ont pour principal objectif de modéliser et de simuler numériquement un coussin de type nid d’abeille de marque ‘‘Stimulite® Honeycomb Cushion’’ en contact avec un fessier afin de pouvoir (i) modéliser le comportement mécanique de contact, (ii) d’évaluer la pression ainsi que la distribution des contraintes à l’interface coussin/fessier, et (iii) d’intégrer les échanges thermomécaniques.Par ailleurs, des essais expérimentaux ont été effectués pour quantifier les lois de comportement des matériaux constituants le coussin nid d’abeille. J’ai également utilisé une nappe permettant de mesurer la pression à l’interface coussin/fessier. Parallèlement, une caméra infrarouge a été utilisée pour mesurer la répartition de la température sur le coussin et le fessier pour une personne assise pendant une durée variable. / The aim of this thesis is to study and improve the comfort of a wheelchair cushion for handicapped, to reduce the appearance of pressure ulcers.In the study, the main objective is to model and simulate numerically a type of cushion, namely ‘‘Stimulite® Honeycomb Cushion Classis’’, in contact with a buttocks-tissue in order to (i) model the mechanical behavior of contact, (ii) evaluate the pressure and the stress distribution at the interface cushion/buttock-tissue, and (iii) integrate thermo-mechanical exchanges.Moreover, the experimental tests were carried out to quantify the law of behavior of material constituent of the honeycomb cushion. I also used a pressure-mapping sensor TexiMat® to measure the pressure at the interface cushion/buttocks-tissue.Meanwhile, an infrared camera was used to measure the temperature distribution on the cushion and buttocks-tissue of a person sitting during variable periods.
97

Efectos de las medias compresivas graduales sobre el organismo tras su uso prolongado

Cambronero Resta, Miguel 10 May 2017 (has links)
En la actualidad, la carrera a pie o running es la 5ª modalidad deportiva más practicada en España. Esta popularidad no es un fenómeno puntual sino que desde los años 70 la participación en carreras populares no ha dejado de crecer. Toda esta oferta unida al auge del deporte del running ha supuesto la aparición de multitud de prendas y complementos para utilizar antes, durante y después de la carrera. Dentro de esos complementos se encuentran las medias compresivas graduales (MCG), cuyo uso en el deporte ha aumentado considerablemente en los últimos años debido a sus efectos potenciales sobre los atletas. Sin embargo, no hay unanimidad sobre si este tipo de prendas ayudan o no en el rendimiento. En el vigente estudio se plantearon los siguientes objetivos: analizar el efecto de las medias compresivas graduales y de la fatiga sobre parámetros cardiorrespiratorios, impactos de aceleración y perímetros de la pierna tras su uso regular durante tres semanas; y evaluar la percepción del confort y de la fatiga de los corredores al llevar las MCG en comparación con las de grupo con medias placebo. Un total de 40 corredores aficionados participaron en el estudio. Para ello, realizaron tres test en tres días diferentes. En el primer test se realizó una carrera de cinco minutos al máximo de sus posibilidades y a una velocidad constante, con el objetivo de determinar su velocidad aeróbica máxima (V AM). En el segundo y tercer test, los participantes realizaron un test de fatiga durante 30 minutos al 80% de su VAM con MCG o placebo, proporcionadas al azar. Los parámetros analizados fueron: a nivel cardiorrespiratorio, la frecuencia cardiaca, la ventilación pulmonar, el consumo relativo de oxígeno, la producción de dióxido de carbono, los equivalentes ventilatorios para el oxígeno y el dióxido de carbono y la saturación de oxígeno. A nivel de impactos, se analizaron el pico de aceleración tibial y de la cabeza, la tasa de aceleración y la atenuación. Por otro lado, se analizaron cuatro perímetros de la pierna y la percepción tanto del confort como de la fatiga. Después de cada test en el laboratorio, los participantes entrenaron con las medias asignadas al azar (MCG o placebo) durante tres semanas. Como resultado del uso de las MCG, no se encontraron diferencias significativas en los parámetros cardiorrespiratorios en comparación con las medias placebo. En los impactos, se redujeron tanto el pico de aceleración de la tibia como la atenuación con el uso de MCG. En la medición de los perímetros no se observaron cambios en función de las medias. Como resultado de la fatiga, se obtuvo un aumento de los parámetros cardiorrespiratorios, de los impactos de aceleración (con excepción del pico de aceleración en la cabeza) en ambos grupos, y una disminución del perímetro de la inserción del tendón de Aquiles solamente en el grupo con MCG. En lo relativo a la percepción del confort y de la fatiga no se obtuvieron cambios significativos tras el uso de tres semanas de las MCG en comparación con el grupo con medias placebo. Por lo tanto, se puede concluir que el uso de medias compresivas durante tres semanas, no tiene efectos en los parámetros cardiorrespiratorios, ni en la percepción del confort ni de la fatiga, ni en los perímetros de la pierna de los corredores, pero sí produce una disminución en el pico de aceleración tibial y en la atenuación.
98

Intégration du comportement des occupants aux simulations énergétiques des bâtiments résidentiels : développement de méthodes et d'outils de conception

Veillette, Debby 30 November 2022 (has links)
Dans les bâtiments résidentiels à haute performance, le comportement des ménages est maintenant l'un des principaux facteurs affectant le confort et la consommation d'énergie. Malgré les progrès technologiques importants en matière d'efficacité énergétique, il demeure un écart considérable entre les prédictions réalisées au moment de la conception et la consommation réelle du bâtiment. À ce jour, il existe peu d'outils d'optimisation du bâtiment prenant en compte la diversité du comportement des occupants. Les outils actuels utilisent généralement des horaires d'occupation fixes, ce qui perpétue l'écart entre les estimations et la performance réelle du bâtiment. De plus, les simulations énergétiques tenant compte du comportement des occupants demandent un grand temps de calcul et sont complexes à implanter en entreprise. Ainsi, il devient essentiel de développer des outils adaptés pour les concepteurs afin d'améliorer l'exactitude des prédictions énergétiques. L'objectif de ce projet est de proposer des outils pour l'optimisation du bâtiment résidentiel, tout en considérant la variabilité du comportement, au moyen de simulations énergétiques. D'une part, une analyse paramétrique sur l'influence de la taille des fenêtres a été menée avec 1000 profils d'occupant différents. Cette étude a permis de conclure que l'importance de chacun des facteurs du comportement changeait selon la taille des fenêtres. Par exemple, lorsque les fenêtres étaient agrandies, l'ouverture des fenêtres influençait moins la demande en chauffage, mais le choix de la température de consigne devenait plus important. D'autre part, une méthode pratique et simplifiée pour considérer le large spectre du comportement, mais en ne générant qu'un nombre réduit de simulations choisies stratégiquement, a été développé. Les simulations énergétiques confirment qu'il est possible de représenter la consommation d'énergie et le confort thermique avec un nombre limité de trois profils d'occupations. En somme, la méthode permet de comparer différentes solutions de design en considérant la diversité du comportement des occupants. / Occupant behavior is now known to be one of the most important parameters affecting thermal comfort and energy consumption, in particular in the residential sector. Despite great technological progress in the field of energy efficiency, huge energy consumption disparities remain to a great extent between prior-to-construction estimations and real energy demand. Nowadays, few optimization tools exist to account for occupant behavior diversity. Usually, single schedules are used to represent occupant behavior, which broaden the gap between estimations and actual consumption. Moreover, energy simulations that include occupant behavior diversity are time-consuming and complex to implement in the industry. Il becomes essential to develop tools that are adapted for practitioners to increase energy predictions reliability. The objective of this study is to propose optimisation tools for the residential sector considering the occupant behavior variability through energy simulations. First, a parametric study has been conducted to measure the influence of window-to-wall ratio with 1000 different occupancy profiles. This exploratory work shows that the relative importance of different occupant behavior aspects can change depending on the window-to-wall ratio. For example, when windows are enlarged, window opening becomes less influential on the heating demand, but, on the other hand, the choice of temperature set point becomes more influential. Afterward, a practical and simple method has been developed to consider thew hole spectrum of occupant behavior, but with a reduced number of strategically chosen profiles. Energy simulations showed that it was possible to represent energy demand and thermal comfort with a limited number of three occupancy profiles. In short, this method allows one to compare different design solutions by considering occupant behavior diversity.
99

La maison tube des nouveaux quartiers d'Hanoï : effets de paramètres architecturaux sur l'ambiance thermique

Nguyen, Dieu Linh 17 April 2018 (has links)
Dans les pays tropicaux, comme le Vietnam, les gens vivent en permanence avec la chaleur et l'humidité, deux causes principales de conditions inconfortables. L'architecture traditionnelle vietnamienne a réduit les impacts négatifs du climat sur l'ambiance thermique à l'aide d'espaces ouverts tels des jardins, des cours intérieures et des puits de lumière. Toutefois, dans les maisons en milieu urbain, l'adaptation au climat a été minimisée à cause de leurs traits typologiques. Ces maisons, qui sont des habitations typiques de Hanoi depuis plusieurs décennies, sont étroites et profondes. De ces faits, pour les maisons de ville, en arriver à un design permettant d'obtenir à la fois le confort thermique et l'économie énergétique est toujours un défi pour l'architecte. Une bonne stratégie architecturale est donc particulièrement importante. Cette stratégie doit à la fois procurer une ambiance thermique intérieure confortable et minimiser l'utilisation d'appareils de climatisation, considérée comme une perte du point de vue énergétique. L'objectif principal de cette recherche est d'étudier l'influence de différentes stratégies architecturales sur la qualité de l'ambiance thermique dans la maison tube des nouveaux quartiers d'Hanoi. Cette étude a été réalisée à l'aide de simulations thermiques dynamiques avec le logiciel Derob-LTH. L'ensemble des résultats obtenus a permis de confirmer la plupart des hypothèses de recherche. Selon ces résultats, on peut conclure que les stratégies architecturales ont influencé l'ambiance thermique intérieure des maisons urbaines. De plus, on peut voir que certaines stratégies à faible coût et très simples à appliquer peuvent améliorer significativement l'ambiance thermique intérieure. Finalement, ce mémoire suggère une combinaison de stratégies architecturales pouvant augmenter significativement l'ambiance thermique intérieure des maisons urbaines.
100

Análisis dinámico del confort en edificios con estrategias de control adaptativo en modos deslizantes

Florez Montes, Frank 02 November 2020 (has links)
[ES] En esta tesis de doctorado se utiliza el modelado matemático de zonas térmicas para evaluar la capacidad del control en modos deslizantes, para regular la temperatura interna de un caso de estudio. Se utiliza la técnica de parámetros agrupados para representar los espacios cerrados, que al ser complementada con mediciones experimentales y algoritmos de optimización, permitió construir un simulador para reproducir con una precisión de más del 97% las condiciones del modelo estudiado, y que permitió estudiar el sistema en general mientras se introducen perturbaciones o variaciones en los parámetros del modelo. Inicialmente se utilizaron modelos de escala reducida para caracterizar el efecto termo-aislante de la solución Thermo Skold sobre la temperatura interna, se caracterizó el efecto de la pintura sobre cada uno de los parámetros de transmisión de calor del caso de estudio, lo que permitió entender los ahorros y resultados obtenidos experimentalmente. Posteriormente, se utilizaron los modelos de escala reducida para evaluar la técnica de control en modos deslizantes, por lo que se modeló, simuló y veri ficó experimentalmente la efectividad de la técnica para mantener una temperatura de referencia ja, con un error inferior al 2 %. En la etapa final de la tesis se utilizó un domo geodésico como caso de estudio, el cual fue modelado con un circuito eléctrico propuesto para sus características específi cas. Se realizaron medidas experimentales de las condiciones térmicas del domo geodésico, con las cuales se ajustó el simulador utilizando el algoritmo de optimización Búsqueda de Patrones. Gracias al simulador desarrollado se estudiaron las condiciones de confort térmico y las necesidades de refrigeración del domo, considerando diferentes situaciones y cargas internas por ocupantes y sistemas de refrigeración. / [EN] In this doctoral thesis, the mathematical modeling of thermal zones is used to evaluate the ability of the control in sliding modes, to regulate the internal temperature of a case study. The grouped parameters technique is used to represent the closed spaces, which, when complemented with experimental measurements and optimization algorithms, allowed the construction of a simulator to reproduce the conditions of the model studied with an accuracy of more than 97 %, which allowed studying the system in general while introducing disturbances or variations in the model parameters. Initially, reduced-scale models were used to characterize the thermal insulating effect of the Thermo Skold solution on the internal temperature. The impact of the painting on each one of the heat transfer parameters was studied, which allowed us to understand the savings and results obtained experimentally. Subsequently, the reduced scale models were used to evaluate the control technique in sliding modes, so the effectiveness of the technique was modeled, simulated and verified experimentally to maintain a fixed reference temperature, with an error of less than 2%. In the final stage of the thesis, a geodesic dome was used as a case study, which was modeled with an electrical circuit proposed for its specific characteristics. Experimental measurements of the thermal conditions of the geodesic dome were made, with which the simulator was adjusted using the Pattern Search optimization algorithm. Thanks to the simulator developed, the thermal comfort conditions and the cooling needs of the dome were studied, considering different situations and internal loads by occupants and cooling systems. / [CA] En aquesta tesi de doctorat s'utilitza el modelatge matemàtic de zones tèrmiques per avaluar la capacitat de l'control en maneres lliscants, per regular la temperatura interna d'un cas d'estudi. S'utilitza la tècnica de paràmetres agrupats per representar els espais tancats, que a l'ésser complementada amb mesuraments experimentals i algoritmes d'optimització, va permetre construir un simulador per reproduir amb una precisió de més de l' 97 % les condicions de el model estudiat, i que va permetre estudiar el sistema en general mentre s'introdueixen pertorbacions o variacions en els paràmetres de el model. Inicialment es van utilitzar models d'escala reduïda per caracteritzar l'efecte termo-aïllant de la solució Thermo Skold sobre la temperatura interna, es va caracteritzar l'efecte de la pintura sobre cadascun dels paràmetres de transmissió de calor de l' cas d'estudi, el que va permetre entendre els estalvis i resultats obtinguts experimentalment. Posteriorment, es van utilitzar els models d'escala reduïda per avaluar la tècnica de control en maneres lliscants, de manera que es va modelar, simular i va verificar experimentalment l'efectivitat de la tècnica per mantenir una temperatura de referència fixa, amb un error inferior a el 2 % . En l'etapa final de la tesi es va utilitzar un dom geodèsic com a cas d'estudi, el qual va ser modelat amb un circuit elèctric proposat per les seves característiques especifiques. Es van realitzar mesures experimentals de les condicions tèrmiques de l'dom geodèsic, amb les quals es va ajustar el simulador utilitzant l'algoritme d'optimització Cerca de Patrons. Gràcies a el simulador desenvolupat es van estudiar les condicions de confort tèrmic i les necessitats de refrigeració de la cúpula, considerant diferents situacions i càrregues internes per ocupants i sistemes de refrigeració. / Al programa de becas de doctorados nacionales convocatoria 727 de Colciencias, por todos los recursos aportados durante el desarrollo de mis estudios. Finalmente, a la Universidad Nacional de Colombia sede Manizales y a la Universidad Politècnica de Valencia, que con sus programas de doctorado en ingeniería automática y matemáticas aplicadas contribuyeron en mi formación como investigador. / Florez Montes, F. (2020). Análisis dinámico del confort en edificios con estrategias de control adaptativo en modos deslizantes [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/153803 / TESIS