• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 371
  • 6
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 389
  • 281
  • 268
  • 218
  • 100
  • 89
  • 86
  • 60
  • 55
  • 54
  • 50
  • 47
  • 41
  • 41
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Desenvolvimento de metodologias indicativas de estabilidade para medicamentos que atuam no diabetes mellitus tipo II / Development of stability indicating methods for drugs that are used in diabetes mellitus 2

Galdos, Angel Arturo Gaona 23 November 2012 (has links)
O diabetes mellitus (DM) é uma síndrome na qual o metabolismo de hidratos de carbono, gorduras e proteínas está alterado, por falta de secreção de insulina ou por diminuição da sensibilidade tissular a este hormônio. O DM pode ser do tipo I, também denominado diabetes mellitus insulinodependente (DMID), caracterizado pela falta de secreção da insulina, e do tipo II, também denominado diabetes mellitus não insulinodependente (DMNID), caracterizado pela menor sensibilidade dos tecidos efetores às ações metabólicas da insulina. Embora ainda não haja cura definitiva, há vários tratamentos disponíveis que proporcionam qualidade de vida para o paciente portador, como a administração de hipoglicemiantes orais. Nesta pesquisa, objetivou-se desenvolver métodos indicativos de estabilidade para a glibenclamida e o cloridrato de metformina. Assim, foram desenvolvidos métodos de rastreamento ortogonais utilizando a cromatografia líquida de alta eficiência (HPLC) e a eletroforese capilar (CE), metodologias que foram desafiadas com os estudos da degradação forçada. Realizou-se, também, a identificação do principal produto de degradação da glibenclamida utilizando a cromatografia líquida acoplada à espectrometria de massa (LC-MS). O método por HPLC teve o melhor desempenho no monitoramento dos produtos de degradação da glibenclamida, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL; com coeficiente de correlação maior de 0,99. A precisão calculada como desvio padrão relativo (DPR) foi menor de 3%, exatidão do método comprovada mediante teste de recuperação, obtendo-se valores de 100±3,0%. No teste de especificidade, foram detectados três potenciais produtos de degradação, com os seguintes tempos de retenção relativos (TRR) de 0,33; 0,46 e 0,83. O método CZE teve o melhor desempenho no monitoramento dos produtos de degradação do cloridrato de metformina, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL, com coeficiente de correlação maior de 0,99. A precisão, calculada como DPR, foi menor do que 5%, exatidão do método comprovada mediante o teste de recuperação, obtendo-se valores de 100±3,5%. No teste de especificidade, foram detectados cinco potenciais produtos de degradação com os seguintes TRRs de 0,90; 1,14; 1,35; 1,45 e 1,56. / Diabetes mellitus (DM) is a syndrome which alters the metabolism of carbohydrates, fats and proteins by lack of insulin secretion or a decrease in tissue sensitivity to insulin. Type 1 DM is also known as insulin-dependent diabetes mellitus is characterized by lack of insulin secretion. The second type of diabetes known as Type II, also called non-insulin dependent, is characterized by the reduced sensitivity of target tissues to the metabolic actions of insulin. Although there is no definitive cure, there are several treatments available that provide quality of life for the patient how treatment with oral hypoglycemic agents. This study had as objective to developed stability-indicating methods for glibenclamide and metformin hydrochloride. Thus, the techniques used in this study involved high performance liquid chromatography (HPLC) and capillary electrophoresis (CE), and both were challenged with forced degradation studies. The identification of degradation products of glibenclamide was also performed, utilizing the mass spectrometry (MS) technique. However, the HPLC technique had the best performance for monitoring the degradation products of glibenclamide, which showed a good linearity in concentrations between 0.210 - 0.360 mg/ml, with a correlation coefficient greater than 0.99. The precision was calculated as a relative standard deviation (RSD) which was less than 3%; the accuracy of the method calculated as the percent recovery was obtained with the following values: 100 ± 3.0%. On the specificity were detected three potential products of degradation utilizing forced degradation, with the following relative retention times (RRT) 0.33, 0.46 and 0.83. The CZE method had the best performance to monitoring the degradation products of metformin hydrochloride, which showed good linearity of concentrations between 0.210 and 0.360 mg/ml, with a correlation coefficient greater than 0.99. The intra-day and inter-day precision calculated as DPR was less than 5%, and an accuracy of this method was achieved using the values of 100 ± 3.5%. In the specificity were five potential degradation products were detected with the following TRRS: 0.90, 1.14, 1.35, 1.45 and 1.56.
252

Validação de métodos para análise de estatinas em medicamentos por cromatografia líquida de alta eficiência e eletroforese capilar / Validation of methods for analysis of statins in pharmaceutical preparations by high performance liquid chromatography and capillary electrophoresis

González Tejerina, Karina Litzi 05 December 2011 (has links)
As estatinas são os fármacos mais usados para tratamento das hiperlipidemias em prevenção primária e secundária, com o propósito de diminuir os níveis de lipoproteínas plasmáticas ricas em colesterol e reduzir os riscos de doença arterialcoronária (DAC) (WITZTUM, 2005). Estes efeitos são resultantes da atividade inibidora das estatinas sobre a enzima HMG-CoA redutase (hidroximetilglutaril-CoA redutase), com a propriedade de bloquear a conversão do substrato HMG-CoA em ácido mevalônico, inibindo os primeiros passos da biossíntese de colesterol. Estas substâncias, (fluvastatina FS, atorvastatina ATC e rosuvastatina RC) são capazes de mimetizar o substrato natural. Podem ser divididas em naturais e sintéticas e diferem fundamentalmente, em termos de potência, perfil farmacocinético, interação farmacológica e efeito indesejado relacionado à miotoxicidade. Na presente pesquisa foram desenvolvidos e validados métodos analíticos de separação (cromatografia liquida de alta eficiência e eletroforese capilar) para cada fármaco. Estes métodos foram aplicados a medicamentos comercializados no Brasil. O método por CLAE foi realizado em coluna LiChrospher® RP-18 (125x4 mm, 5µm) Merck® e uma fase móvel composta por metanol:água (70:30 v/v) para FS e ATC, (60:40 v/v) para RC, com 5 mM trietilamina e pH ajustado para 3.0 com ácido ortofosfórico. O método mostrou boa linearidade (r 0,9915), (LD 2,02 e LQ 6,12) FS; (r 0,9959), (LD 0,44 e LQ 1,34) ATC e (r 0,9945), (LD 1,55 e LQ 4,70) RC. A exatidão foi expressa em porcentagem de recuperação (R% 99,59) FS, (R% 100,24) ATC e (R% 99,2). Pelo método MEKC foi realizado utilizando capilar de sílica fundida de 40,2 cm x 75 m d. i. (30 cm até detector); eletrólito: tampão borato 20 mM: SDS 30 mM: metanol10% v/v pH 9,24; voltagem aplicada: +22 kV; injeção: hidrodinâmica 0,5 psi/3s, apresentaram linearidade (r 0,9997), (LD 0,94 e LQ 2,85) FS; (r 0,9999), (LD 2,36 e LQ 7,17) ATC. A porcentagem de recuperação (R% 104,61) FS, (R% 103,96) ATC. Pelo método CZE foi realizado utilizando sílica fundida de 40,2 cm de cumprimento sendo 30 cm até o detector, 75 µm de d.i. e 375 µm de d.d., eletrólito: tampão tetraborato de sódio 20 mM, pH 9,20; voltagem aplicada: +25kV; injeção: hidrodinâmica 0,5 psi/5s, apresentou linearidade (r 0,9989), (LD 4,92 e LQ 14,91) RC; A porcentagem de recuperação (R% 100,66) RC. / Statins are the drugs most commonly used for treatment of hyperlipidemia in primary and secondary prevention, with the aim of reducing levels of lipoproteins rich in cholesterol and reduce the risk of coronary-artery disease (CAD) (Witztum, 2005). These effects are due to the inhibitory activity of statins on the enzyme HMG-CoA reductase (hydroxymethylglutaryl CoA reductase), with the property to block the conversion of the substrate HMG-CoA to mevalonic acid, inhibiting the first steps of cholesterol biosynthesis. These substances (fluvastatin FS, atorvastatin ATC and rosuvastatin RC) may mimic the natural substrate, can be divided into natural and synthetic, and differ fundamentally in terms of potency, pharmacokinetics, drug interactions and unwanted effects related to muscle-toxicity. In the present study were developed and fully validated analytical methods of separation (high efficiency liquid chromatography and capillary electrophoresis) for each drug. These methods were applied to drugs marketed in Brazil. The method was performed by HPLC column LiChrospher® RP-18 (125x4 mm, 5mm) Merck® and a mobile phase consisting of methanol: water (70:30 v / v) for FS and ATC (60:40 v / v) to RC, with 5 mM triethylamine and pH adjusted to 3.0 with orthophosphoric acid. The method showed good linearity (r 0.9915), (2.02 LD and LQ 6.12) FS; (r 0.9959), (0.44 LD and LQ 1.34) ATC; (r 0.9945), (1.55 LD and LQ 4.70) for RC. The accuracy was expressed as a percentage of recovery (R% 99.59%) FS, (R% 100.24) ATC and (R 99.2%) RC. The MEKC method was performed using a fused silica capillary of 40.2 cm x 75 m d. i. (30 cm to detector); electrolyte: 20 mM borate buffer: 30 mM SDS: metanol10% v / v pH 9.24, applied voltage: +22 kV, injection: hydrodynamic psi/3s 0.5 showed linearity (r 0, 9997), (LQ 0.94 and LD 2.85) FS, (r 0.9999), (LQ 2.36 and LD 7.17) ATC. The percentage recovery (% R 104.61) FS, (R 103.96%) ATC. The CZE method was performed using fused silica of 40.2 cm long and 30 cm to the detector, 75 mm in di and 375 mm in dd, electrolyte: sodium tetraborate buffer 20 mM, pH 9.20, applied voltage: +25 kV, injection: hydrodynamic psi/5s 0.5, showed linearity (r 0.9989), (4.92 LD and LQ 14.91) RC; The percentage recovery (% R 100.66) RC.
253

Emprego de miniSTRs \"non-CODIS\" em amostras biológicas de DNA forense. / The use of \"non-CODIS\" miniSTRS in forensic DNA biological samples.

Pacheco, Ana Claudia 15 December 2010 (has links)
Foram analisadas 80 amostras de casos forenses criminais do Laboratório de DNA do Instituto de Criminalística de São Paulo. O DNA foi extraído de materiais cadavéricos, vestígios de crimes sexuais e de locais de crimes. A quantificação se deu por PCR em tempo real e a amplificação por PCR, em 2 reações triplex, dos miniSTRs non-CODIS D10S1248, D14S1434 e D22S1045 (NCO01) e D1S1677, D2S441 e D4S2364 (NCO02), com posterior eletroforese capilar para detecção dos produtos fluorescentes. Avaliou-se o grau de conservação das amostras e a qualidade dos perfis genéticos obtidos. Houve concordância nas dificuldades entre diferentes amostras quando comparado com as abordagens tradicionais. Confirmou-se a sensibilidade e robustez dos sistemas utilizados, bem como a vantagem em se aumentar o número de regiões analisadas, principalmente em casos complexos, mas foram constatadas desvantagens de procedimentos tipo in-house. É necessário o estudo das frequências alélicas destes loci para a população brasileira, que possam ser incorporadas nos cálculos estatísticos dos laudos. / 80 forensic casework samples from the DNA Laboratory of the Criminalistics Institute of São Paulo were analyzed. DNA was extracted from corpse, sexual assault and crime scene evidence. The extractions were quantified using real-time PCR, amplified by two triplex PCR reactions of the non-CODIS miniSTRs D10S1248, D14S1434, D22S1045 (NC01) and D1S1677, D2S441, D4S2364 (NC02), followed by capillary electrophoresis to detect the fluorescent products. The sample preservation and quality of the genetic profiles obtained were evaluated. The results were compared to the previous obtained with the routine techniques employed in the laboratory and there was concordance in the relative difficulties. The sensibility and robustness of the systems employed were confirmed, as well as the advantages in increasing the number of loci studied, mainly in complex cases, although the in-house procedures were considered a disadvantage. The establishment of brazilian population allele frequencies for these loci is necessary for the statistical calculations of the forensic reports.
254

Desenvolvimento, validação e comparação de métodos analíticos para determinação de bloqueadores neuromusculares derivados de esteróides / Development, validation and comparison of analytical methods for determination of neuromuscular blocking derivatives of steroids

Pedro López García 10 August 2009 (has links)
Os relaxantes neuromusculares não despolarizantes são fármacos indispensáveis nos procedimentos cirúrgicos que requerem entubação endotraqueal, visto que diminuem o tônus muscular. Quimicamente são divididos em derivados isoquinolinicos e derivados de esteróides, esses últimos com maior aplicação clinica e comercialização no Brasil. Assim sendo, é importante a validação de métodos analíticos para o controle de qualidade com alternativas confiáveis que garantam sua eficácia e segurança. Os brometos de vecurônio, de pancurônio e de rocurônio são fármacos relaxantes neuromusculares não despolarizantes derivados de esteróides. As propriedades farmacológicas destes fármacos são significativamente diferentes entre si, porém, as propriedades químicas são bastante similares. Na presente pesquisa foram desenvolvidos e validados métodos analíticos de separação (cromatografia líquida de alta eficiência e eletroforese capilar) para cada fármaco. Estes métodos foram aplicados a medicamentos comercializados no Brasil. Para todos os métodos cromatográficos foi utilizada uma coluna amino devido a seu caráter polar. Em função da baixa absorção dos três fármacos na região ultravioleta, os métodos eletroforéticos foram aplicados com detecções indiretas utilizando substâncias cromóforas. Comparando-se as técnicas utilizadas para determinação dos fármacos nos medicamentos isoladamente, não houve diferença significativa com nível de confiança de 95,0%. Nos testes de hipótese aplicados (F-Snedecor e t-Student), não foram observadas diferenças na precisão (variâncias) e no valor encontrado dos fármacos contidos nas amostras estudadas (comparação de duas médias). / The non-depolarizing neuromuscular relaxant drugs are essential in surgical procedures requiring endotracheal intubation, as they decrease muscle tonics. These drugs are chemically divided in isoquinolines derivatives and steroid derivatives, this latter group, with greater clinical application and commercialization in Brazil. Therefore, the study and validation of analytical methods are important for quality control with reliable alternatives to ensure their effectiveness and safety. The vecuronium, pancuronium and rocuronium bromides are steroid derivatives presenting non-depolarizing neuromuscular relaxant action. Pharmacological properties of these drugs differ significantly, however, its chemical properties are quite similar. In this research, analytical separation methods (high performance liquid chromatography and capillary electrophoresis), for each drug, were developed and fully validated. The methods were applied to pharmaceutical formulations commercialized in Brazil. For all chromatographic methods, an amino column was used, due to its polar characteristics. Due to the low absorption of the three drugs in the ultraviolet region, electrophoretic methods has been applied with indirect detection using chromophoric substances. When comparing both techniques used for quantitative determination of these drugs in pharmaceutical products, no significant difference was observed using a confidence level of 95.0%. By applying hypothesis tests (F-Snedecor and t-Student), it was not observed difference in precision (variance) and in the found amount of drugs contained in the selected samples (comparison of two means).
255

Determinação quantitativa de gemifloxacino por cromatografia líquida de alta eficiência e eletroforese capilar / Quantitative determination of gemifloxacin mesylate in tablets by capillary zone electrophoresis and high performance liquid chromatography

Vanessa Franco Tavares 25 August 2010 (has links)
Gemifloxacino (GMFLX) é um agente fluorquinôlonico, antibacteriano recentemente desenvolvido que apresenta um amplo espectro de atividade. O objetivo deste estudo foi desenvolver e validar métodos seletivos e sensíveis para a determinação quantitativa de GMFLX em comprimidos revestidos por cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar de zona (CZE). O método por CLAE foi realizado em uma coluna LiChrospher&#174; 100 RP-8e, 5&#181;m (125 x 4 mm) e uma fase móvel composta por tetraidrofurano:água (25:75, v/v) com 0.5% de trietilamina e pH ajustado para 3.0 com ácido ortofosfórico. O tempo de retenção do GMFLX foi de 2.3 min. O método mostrou boa linearidade (r2 0.9989) e precisão (RSD% < 0.89). A exatidão foi expressa em percentagem de recuperação (R% &#8804; 101.3%). O método por CZE foi realizado utilizando 50 mmol L-1 de tampão tetraborato de sódio (pH 8.6). As amostras foram injetadas hidrodinâmicamente (0.5 psi, 5s) e o sistema eletroforético foi operado sob polaridade normal, em +20 kV e temperatura de 18 °C. O capilar utilizado foi de sílica fundida de 40.2 cm de comprimento (30 cm efetivos) x 75 &#181;m (d.i.) x 375 &#181;m (d.e.). Esse método apresentou um tempo de migração de 2.55 min para o GMFLX e 1.66 min para o metoprolol (padrão interno). Os parâmetros avaliados apresentaram linearidade (r2 0.9992), precisão (RSD% < 4.2) e exatidão (R% &#8804; 101.8%). Tanto a CLAE quanto a CZE foram consideradas técnicas interessantes e eficientes para serem aplicadas no controle de qualidade em indústrias farmacêuticas. / Gemifloxacin (GMFLX) is a recently developed fluorquinolone antibacterial agent presenting a broad spectrum of activity. The aim of this study was to develop and validate selective and sensitive methods for quantitative determination of GMFLX in coated tablets by high performance liquid chromatography (HPLC) and capillary zone electrophoresis (CZE). The HPLC method was carried out on a LiChrospher&#174; 100 RP-8e, 5&#181;m (125 x 4 mm) column with a mobile phase composed of tetrahydrofuran-water (25:75, v/v) with 0.5% of triethylamine and pH adjusted to 3.0 with orthophosphoric acid. The retention time of GMFLX was 2.3 min. The method showed good linearity (r2 0.9989) with good precision (RSD < 0.89%). Accuracy was expressed as percentage recovery (R% &#8804; 101.3%). The CZE method was performed using 50 mmoL-1 sodium tetraborate buffer (pH 8.6). Samples were injected hydrodynamicaly (0.5 psi, 5s) and the electrophoretic system was operated under normal polarity, at +20kV and temperature of 18°C. A fused-silica capillary 40.2 cm (30 cm effective length) x 75 &#181;m (i.d.) x 375 &#181;m (o.d.) was used. This method presented a migration time of 2.55 min for GMFLX and 1.66 min for metoprolol (internal standard). The evaluated parameters presented acceptable linearity (r2 0.9992), precision (RSD < 4.2%) and accuracy (R% &#8804; 101.8%). Both, HPLC and CZE method could be interesting and efficient techniques to be applied for quality control in pharmaceutical industries.
256

Desenvolvimento de metodologias indicativas de estabilidade para medicamentos que atuam no diabetes mellitus tipo II / Development of stability indicating methods for drugs that are used in diabetes mellitus 2

Angel Arturo Gaona Galdos 23 November 2012 (has links)
O diabetes mellitus (DM) é uma síndrome na qual o metabolismo de hidratos de carbono, gorduras e proteínas está alterado, por falta de secreção de insulina ou por diminuição da sensibilidade tissular a este hormônio. O DM pode ser do tipo I, também denominado diabetes mellitus insulinodependente (DMID), caracterizado pela falta de secreção da insulina, e do tipo II, também denominado diabetes mellitus não insulinodependente (DMNID), caracterizado pela menor sensibilidade dos tecidos efetores às ações metabólicas da insulina. Embora ainda não haja cura definitiva, há vários tratamentos disponíveis que proporcionam qualidade de vida para o paciente portador, como a administração de hipoglicemiantes orais. Nesta pesquisa, objetivou-se desenvolver métodos indicativos de estabilidade para a glibenclamida e o cloridrato de metformina. Assim, foram desenvolvidos métodos de rastreamento ortogonais utilizando a cromatografia líquida de alta eficiência (HPLC) e a eletroforese capilar (CE), metodologias que foram desafiadas com os estudos da degradação forçada. Realizou-se, também, a identificação do principal produto de degradação da glibenclamida utilizando a cromatografia líquida acoplada à espectrometria de massa (LC-MS). O método por HPLC teve o melhor desempenho no monitoramento dos produtos de degradação da glibenclamida, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL; com coeficiente de correlação maior de 0,99. A precisão calculada como desvio padrão relativo (DPR) foi menor de 3%, exatidão do método comprovada mediante teste de recuperação, obtendo-se valores de 100±3,0%. No teste de especificidade, foram detectados três potenciais produtos de degradação, com os seguintes tempos de retenção relativos (TRR) de 0,33; 0,46 e 0,83. O método CZE teve o melhor desempenho no monitoramento dos produtos de degradação do cloridrato de metformina, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL, com coeficiente de correlação maior de 0,99. A precisão, calculada como DPR, foi menor do que 5%, exatidão do método comprovada mediante o teste de recuperação, obtendo-se valores de 100±3,5%. No teste de especificidade, foram detectados cinco potenciais produtos de degradação com os seguintes TRRs de 0,90; 1,14; 1,35; 1,45 e 1,56. / Diabetes mellitus (DM) is a syndrome which alters the metabolism of carbohydrates, fats and proteins by lack of insulin secretion or a decrease in tissue sensitivity to insulin. Type 1 DM is also known as insulin-dependent diabetes mellitus is characterized by lack of insulin secretion. The second type of diabetes known as Type II, also called non-insulin dependent, is characterized by the reduced sensitivity of target tissues to the metabolic actions of insulin. Although there is no definitive cure, there are several treatments available that provide quality of life for the patient how treatment with oral hypoglycemic agents. This study had as objective to developed stability-indicating methods for glibenclamide and metformin hydrochloride. Thus, the techniques used in this study involved high performance liquid chromatography (HPLC) and capillary electrophoresis (CE), and both were challenged with forced degradation studies. The identification of degradation products of glibenclamide was also performed, utilizing the mass spectrometry (MS) technique. However, the HPLC technique had the best performance for monitoring the degradation products of glibenclamide, which showed a good linearity in concentrations between 0.210 - 0.360 mg/ml, with a correlation coefficient greater than 0.99. The precision was calculated as a relative standard deviation (RSD) which was less than 3%; the accuracy of the method calculated as the percent recovery was obtained with the following values: 100 ± 3.0%. On the specificity were detected three potential products of degradation utilizing forced degradation, with the following relative retention times (RRT) 0.33, 0.46 and 0.83. The CZE method had the best performance to monitoring the degradation products of metformin hydrochloride, which showed good linearity of concentrations between 0.210 and 0.360 mg/ml, with a correlation coefficient greater than 0.99. The intra-day and inter-day precision calculated as DPR was less than 5%, and an accuracy of this method was achieved using the values of 100 ± 3.5%. In the specificity were five potential degradation products were detected with the following TRRS: 0.90, 1.14, 1.35, 1.45 and 1.56.
257

Validação de métodos para análise de estatinas em medicamentos por cromatografia líquida de alta eficiência e eletroforese capilar / Validation of methods for analysis of statins in pharmaceutical preparations by high performance liquid chromatography and capillary electrophoresis

Karina Litzi González Tejerina 05 December 2011 (has links)
As estatinas são os fármacos mais usados para tratamento das hiperlipidemias em prevenção primária e secundária, com o propósito de diminuir os níveis de lipoproteínas plasmáticas ricas em colesterol e reduzir os riscos de doença arterialcoronária (DAC) (WITZTUM, 2005). Estes efeitos são resultantes da atividade inibidora das estatinas sobre a enzima HMG-CoA redutase (hidroximetilglutaril-CoA redutase), com a propriedade de bloquear a conversão do substrato HMG-CoA em ácido mevalônico, inibindo os primeiros passos da biossíntese de colesterol. Estas substâncias, (fluvastatina FS, atorvastatina ATC e rosuvastatina RC) são capazes de mimetizar o substrato natural. Podem ser divididas em naturais e sintéticas e diferem fundamentalmente, em termos de potência, perfil farmacocinético, interação farmacológica e efeito indesejado relacionado à miotoxicidade. Na presente pesquisa foram desenvolvidos e validados métodos analíticos de separação (cromatografia liquida de alta eficiência e eletroforese capilar) para cada fármaco. Estes métodos foram aplicados a medicamentos comercializados no Brasil. O método por CLAE foi realizado em coluna LiChrospher® RP-18 (125x4 mm, 5&#181;m) Merck® e uma fase móvel composta por metanol:água (70:30 v/v) para FS e ATC, (60:40 v/v) para RC, com 5 mM trietilamina e pH ajustado para 3.0 com ácido ortofosfórico. O método mostrou boa linearidade (r 0,9915), (LD 2,02 e LQ 6,12) FS; (r 0,9959), (LD 0,44 e LQ 1,34) ATC e (r 0,9945), (LD 1,55 e LQ 4,70) RC. A exatidão foi expressa em porcentagem de recuperação (R% 99,59) FS, (R% 100,24) ATC e (R% 99,2). Pelo método MEKC foi realizado utilizando capilar de sílica fundida de 40,2 cm x 75 m d. i. (30 cm até detector); eletrólito: tampão borato 20 mM: SDS 30 mM: metanol10% v/v pH 9,24; voltagem aplicada: +22 kV; injeção: hidrodinâmica 0,5 psi/3s, apresentaram linearidade (r 0,9997), (LD 0,94 e LQ 2,85) FS; (r 0,9999), (LD 2,36 e LQ 7,17) ATC. A porcentagem de recuperação (R% 104,61) FS, (R% 103,96) ATC. Pelo método CZE foi realizado utilizando sílica fundida de 40,2 cm de cumprimento sendo 30 cm até o detector, 75 &#181;m de d.i. e 375 &#181;m de d.d., eletrólito: tampão tetraborato de sódio 20 mM, pH 9,20; voltagem aplicada: +25kV; injeção: hidrodinâmica 0,5 psi/5s, apresentou linearidade (r 0,9989), (LD 4,92 e LQ 14,91) RC; A porcentagem de recuperação (R% 100,66) RC. / Statins are the drugs most commonly used for treatment of hyperlipidemia in primary and secondary prevention, with the aim of reducing levels of lipoproteins rich in cholesterol and reduce the risk of coronary-artery disease (CAD) (Witztum, 2005). These effects are due to the inhibitory activity of statins on the enzyme HMG-CoA reductase (hydroxymethylglutaryl CoA reductase), with the property to block the conversion of the substrate HMG-CoA to mevalonic acid, inhibiting the first steps of cholesterol biosynthesis. These substances (fluvastatin FS, atorvastatin ATC and rosuvastatin RC) may mimic the natural substrate, can be divided into natural and synthetic, and differ fundamentally in terms of potency, pharmacokinetics, drug interactions and unwanted effects related to muscle-toxicity. In the present study were developed and fully validated analytical methods of separation (high efficiency liquid chromatography and capillary electrophoresis) for each drug. These methods were applied to drugs marketed in Brazil. The method was performed by HPLC column LiChrospher® RP-18 (125x4 mm, 5mm) Merck® and a mobile phase consisting of methanol: water (70:30 v / v) for FS and ATC (60:40 v / v) to RC, with 5 mM triethylamine and pH adjusted to 3.0 with orthophosphoric acid. The method showed good linearity (r 0.9915), (2.02 LD and LQ 6.12) FS; (r 0.9959), (0.44 LD and LQ 1.34) ATC; (r 0.9945), (1.55 LD and LQ 4.70) for RC. The accuracy was expressed as a percentage of recovery (R% 99.59%) FS, (R% 100.24) ATC and (R 99.2%) RC. The MEKC method was performed using a fused silica capillary of 40.2 cm x 75 m d. i. (30 cm to detector); electrolyte: 20 mM borate buffer: 30 mM SDS: metanol10% v / v pH 9.24, applied voltage: +22 kV, injection: hydrodynamic psi/3s 0.5 showed linearity (r 0, 9997), (LQ 0.94 and LD 2.85) FS, (r 0.9999), (LQ 2.36 and LD 7.17) ATC. The percentage recovery (% R 104.61) FS, (R 103.96%) ATC. The CZE method was performed using fused silica of 40.2 cm long and 30 cm to the detector, 75 mm in di and 375 mm in dd, electrolyte: sodium tetraborate buffer 20 mM, pH 9.20, applied voltage: +25 kV, injection: hydrodynamic psi/5s 0.5, showed linearity (r 0.9989), (4.92 LD and LQ 14.91) RC; The percentage recovery (% R 100.66) RC.
258

Desenvolvimento de metodologias indicativas de estabilidade para medicamentos utilizados como diuréticos / Development of stability-indicating assay for diuretics drugs.

Aline de Souza 11 December 2015 (has links)
Os diuréticos aumentam o fluxo urinário e a excreção de sódio e são utilizados para ajustar o volume e/ou a composição dos líquidos corporais em uma variedade de situações clínicas. A furosemida é um agente diurético potente que induz uma poderosa diurese. É utilizada no tratamento de edema associado com o coração e doenças renais. Nesta pesquisa objetivou-se desenvolver métodos indicativos de estabilidade para a furosemida, por eletroforese capilar em solução livre (FSCE) e cromatografia liquida de alta eficiência (CLAE). O método por FSCE utilizou um capilar de sílica fundida com comprimento total de 30,2 cm x 50,0 &#181;m d.i. O tampão utilizado foi tetraborato de sódio 2,0 mmol L-1 e 10% de metanol, injeção hidrodinâmica 0,5 psi/5s, tensão aplicada +25 kV, detecção em 273 nm e temperatura a 25ºC. O tempo de migração da furosemida foi de 1,8 minutos. O método obteve boa linearidade no intervalo de 70,0 a 130,0 &#181;g.mL-1 com coeficiente de correlação maior de 0,99. Os limites de detecção e de quantificação foram 6,2 &#181;g.mL-1 e 20,6 &#181;g.mL-1, respectivamente. A precisão do sistema foi inferior a 2,0%. A repetibilidade e precisão intermediária foram inferiores a 5,0%. A recuperação média foi de 102,1 %. No teste de especificidade, foram detectados três potenciais produtos de degradação com os seguintes tempos de retenção 1,3 2,0 e 2,2 min. O método por CLAE utilizou uma coluna Shim-pack CLC-ODS(M)® (250mm x4.6mm, 5&#181;m). A fase móvel era constituída de acetonitrila:água (50:50) com 0,1% de ácido fórmico. O fluxo foi de 1.0 mL min-1 e detecção em 273 nm e temperatura a 30 ± 1 ºC. O método apresentou boa linearidade nas concentrações entre 7,0 e 13 &#181;g.mL-1; com coeficiente de correlação maior de 0,99. E tempo de retenção para furosemida foi de 4,9 minutos. Os limites de detecção e de quantificação foram 0,6 &#181;g.mL-1 e 1,9 &#181;g.mL-1, respectivamente. A precisão do sistema foi inferior a 1,0%. A repetibilidade e precisão intermediária foram inferiores a 3,0%. A recuperação média foi de 105,1 %. No teste de especificidade, foram detectados três potenciais produtos de degradação com os seguintes tempos de retenção 2,4, 3,1 e 3,8 min. / Diuretics increase urine flow and sodium excretion and are used to adjust volume and / or composition of body fluids in a variety of clinical situations. Furosemide is a potent diuretic agent that induces a strong diuresis. It is used in the treatment of edema associated with heart and kidney disease. This research aimed to develop stability indicative methods for furosemide, by capillary electrophoresis in free solution (FSCE) and high-performance liquid chromatography (HPLC). The method FSCE used a fused silica capillary with a total length of 30.2 cm x 50.0 um di The buffer used was sodium tetraborate 2.0 mmol L-1 and 10% methanol, hydrodynamic injection 0.5 psi / 5s, +25 kV applied voltage, detection at 273 nm and 25 °C. The furosemide migration time was 1.8 minutes. The method achieved good linearity in the range of 70.0 to 130.0 &#181;g.mL-1 with correlation coefficient higher of 0.99. The limits of detection and quantification were 6.2 and 20.6 &#181;g.mL-1 &#181;g.mL-1, respectively. The system accuracy was less than 2.0%. The repeatability and intermediate precision were less than 5.0%. The average recovery was 102.1%. The specificity test detected three potential degradation products with the following retention times 1.3, 2.0 and 2.2 min. The HPLC method used a Shim-pack CLC-ODS (M)® column (250mm x 4.6mm, 5&#181;m). The mobile phase consisted of acetonitrile: water (50:50) with 0.1% formic acid. The flow rate was 1.0 mL min-1, detection at 273 nm and temperature at 30 ± 1°C. The method showed good linearity in concentrations between 7.0 and 13.0 &#181;g.mL-1; with correlation coefficient higher of 0.99. Retention time for furosemide was 4.9 minutes. The limits of detection and quantification were 0.6 &#181;g.mL-1 and 1.9 &#181;g.mL-1, respectively. The system accuracy was less than 1.0%. The repeatability and intermediate precision were less than 3.0%. The average recovery was 105.1%. The specificity test detected three potential degradation products of the following retention times of 2.4, 3.1 and 3.8 min.
259

Desenvolvimento e validação de metodologia analítica para identificação e doseamento de medicamentos anti-esquistossomose / Development and validation of analytical methodology for identification and dosing of medicines anti - schistosomiasis.

Elenice Luduvina da Silva Santos 19 January 2016 (has links)
A esquistossomose ou bilharziose, é uma doença produzida por trematódeos do gênero Schistosoma. Dentre as 19 espécies reconhecidas, cinco infectam primariamente o homem: S. mansoni, S. haematobium, S. intercalatum, S. japonicum e S. Mekongi.O número de pessoas com infecção esquistossomótica, em todo o mundo, foi estimado em 200 milhões sendo sua maioria na Ásia e África. Na América do Sul e Caribe encontram-se vários milhões de casos sendo uma estimativa de mais de seis milhões de casos no Brasil. Os fármacos utilizados para o tratamento desta enfermidade são o praziquantel e o oxamniquina, sendo este último o princípio ativo do produto Mansil® cápsulas produzido pela indústria farmacêutica Pfizer. O presente trabalho teve como objetivo desenvolver e validar métodos analíticos por eletroforese capilar (CE) e por cromatografia líquida de alta eficiência (HPLC), rápidos, seletivos e confiáveis para a determinação de oxamniquina em formulações farmacêuticas e de sua impureza (uk-3883), quando houver. A separação cromatográfica foi realizada usando a coluna Thermo® Nucleosil C18 (150 mm x 4,6 mm x 5 &#181;m), com fase móvel constituída por água acidificada com 0,1% ácido ortofosfórico:metanol (40:60 v/v), trabalhando com vazão de 1,0 mL min-1 e volume de injeção de 2 &#181;L. A temperatura da coluna foi controlada em 20 ºC e a detecção foi realizada na região do UV em 254 nm. O tempo de retenção da oxamniquina foi de 1,9 min e da uk-3883 5,1 min. O método por eletroforese capilar de zona (CZE) foi desenvolvido utilizando capilar de sílica fundida de 20 cm (comprimento efetivo) x 50 &#181;m d.i. e eletrólito constituído da solução tampão fosfato de sódio monobásico 30 mmol L-1, pH 2,5 ajustado com ácido orto-fosfórico 10%: metanol 18% v/v. Injeção hidrodinâmica 0,5 psi/3 s; voltagem aplicada de +25 kV, temperatura de 20 ºC e detecção no UV de 254 nm. Os métodos analíticos foram validados de acordo com os requerimentos vigentes da ANVISA, ICH e Farmacopéia Americana. Portanto, os métodos propostos demonstraram linearidade (R2>0,99), precisão (%DPR < 2%), exatidão (>98%, expressado em porcentagem de recuperação) e adequabilidade para a quantificação da oxamniquina em formas farmacêuticas comerciais. / Schistosomiasis or bilharzia, is a disease caused by trematodes of the gender Schistosoma. Among the 19 recognized species, five primarily infect humans: S. mansoni, S. haematobium, S. intercalatum, S. japonicum and S. mekongi. The number of people with schistosomiasis infection worldwide was estimated at 200 million being mostly living in Asia and Africa. In South America and the Caribbean are several million of cases and in Brazil it is stimated of more than six million of cases. The drugs used for the treatment of this disease is praziquantel and oxamniquine, the latter being the active principle of the Mansil® capsules produced by Pfizer pharmaceutical industry. This study aimed to develop and validate fast, selective and reliable analytical methods through capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC), for the determination of oxamniquine in pharmaceutical formulations and its impurity (UK-3883) if any. The chromatographic separation was performed using a Thermo® Nucleosil C18 column (150 mm x 4.6 mm x 5 &#181;m) the mobile phase was composed of water with 0.1% orthophosphoric acid: methanol (40:60 v/v); the flow rate was 1.0 ml min-1. The column temperature was controlled at 20 ° C and the detection was performed with UV detector at 254 nm. The retention time for oxamniquine and its impurity (uk-3883) were 1.9 and 5.1 minutes, respectively. The capillary zone electrophoresis method was developed using an uncoated fused-silica capillary of 20 cm effective length x 50 &#181;m i.d. the electrolyte was composed of 30 mmol L-1 sodium phosphate monobasic buffer solution, pH 2.5 adjusted with ortho-phosphoric acid 10%: 18% methanol v(/v). Samples were injected hydrodynamically at 0.3 psi for 3 s, the detection was made by UV absorption at 254 nm, the capillary temperature was 20ºC and the applied voltage was +25 kV. Analytical methods were validated in accordance with the ANVISA, ICH and United States Pharmacopoeia guidelines. Therefore, the porposed methods showed linearity (R2>0,99), precision (%RSD <2%), accuracy (>98%, expressed as recovery percentage) and suitability for the quantification of oxamniquine in commercial dosage forms.
260

Avaliação quimiométrica de mapas peptídicos urinários obtidos por CE-MS visando o diagnóstico clínico / Chemometric evaluation of CE-MS urinary peptidic maps aiming at clinical diagnostics

Edgar Perin Moraes 21 August 2008 (has links)
A presente tese de doutorado propõe investigar mapas peptídicos urinários via eletroforese capilar acoplada ao espectrômetro de massas e avaliar se existe correlação entre estes e a presença de refluxo vésico-ureteral (RVU), visando desenvolver um novo método não invasivo para diagnosticar RVU em crianças, e ainda averiguar a existência de possíveis biomarcadores para a doença. Vinte e quatro amostras de urina de crianças positivas para RVU e quinze saudáveis, anteriormente submetidas à uretrocistografia miccional, foram disponibilizadas ao nosso grupo. Estas foram filtradas para eliminar proteínas de alta massa molar e pré-concentradas em coluna de fase reversa C2. Os mapas peptídicos foram obtidos via CE-MS em um eletrólito composto por 0,8% de ácido metanóico e 20% de metanol; já o líquido auxiliar consistia em 0,8% de ácido metanóico e 60% de metanol. Diversos métodos de classificação de aglomerados foram experimentados com os mapas peptídicos. Todos indicaram que as variáveis mais importantes para este discernimento eram os picos mais intensos ordenados em blocos de tempo. Entre os métodos de classificação não supervisionada, PCA (Principal Component Analysis) foi o mais perceptível na tarefa de distribuir os conjuntos de amostras. Para este, a porcentagem de acertos entre as amostras positivas foi de 75% e, entre as amostras negativas foi de 86,7%. No entanto, a taxa de erro encontrada por este método foi de 20,5%, não cumprindo o objetivo proposto. Entre os métodos de classificação supervisionada, SVM (Support Vector Machines) foi o selecionado, exprimindo melhor habilidade em prever que os modelos lineares e boa capacidade de generalização. O método otimizado apontou para o uso da função de base radial, o que está de acordo com outros trabalhos na área. Outras três variáveis ajustadas foram o parâmetro capacidade, o responsável por controlar a amplitude da função gaussiana e o &#949;-insensitive loss function. A validação cruzada LOO (leave-one-out) realizada para a rede treinada pelo SVM exibiu 0,00454 para a raiz quadrada da média dos erros e coeficiente de correlação próximo de um, indicando que o ajuste dos dados foi bem realizado. Empregando um mínimo de 80% das amostras para treinamento e 10% para verificação, o modelo foi capaz de classificar corretamente as amostras restantes. Três grupos de amostras para testes foram separados e a rede foi capaz de classificá-los corretamente. Biomarcadores específicos para RVU foram pesquisados durante o trabalho. Peptídeos que apareceram em mais de 70% das amostras de urina positivas para RVU e em menos de 15% das amostras de urina saudáveis foram selecionados. Espectros MS2 foram obtidos para estes peptídeos, e a pesquisa em bancos de espectros indicou um fragmento da imunoglobulina G como um possível candidato. No entanto, a existência de um biomarcador específico para RVU é ainda incerta, carecendo de uma investigação mais aprofundada para se concretizar este objetivo. Nos mapas peptídicos existem disparidades entre os dois grupos de amostras, que foram correlacionadas nesta tese com a presença de refluxo vésico-ureteral, sendo o nosso espaço amostral classificado corretamente / The present doctorate thesis intends to investigate urinary peptides maps by capillary electrophoresis coupled with mass spectrometry (CE-MS) to evaluate whether there is a correlation between these maps and vesicoureteral reflux (VUR) pathology, with the purpose of developing a new non invasive method for RVU diagnosis in children, and to investigate possible biomarkers for the illness. Twenty four urine samples of positive children for RVU and fifteen healthy children samples, previously submitted to the miccional cystourethrography, were available. Samples were filtered to eliminate proteins of high molar mass and preconcentrated in reversed-phase C2 columns. Peptide enriched samples were submitted to analysis by CE-MS in an electrolyte consisted of 0.8% formic acid and 20% methanol; sheath liquid was composed of 0.8% formic acid and 60% methanol. Diverse cluster analysis techniques were attempted to classify the peptide maps. The most important variables for screening were the most intense peaks organized by blocks of time. Among the non supervised methods, PCA (Principal Component Analysis) performed best in the task of discriminating the sample sets. For PCA, 75% of positive samples and 86.7% of negative samples were correctly assigned. However, the error found for this method was 20.5%, not fulfilling the purpose. Among the supervised methods, SVM (Support Vector Machines) performed best, exhibiting better prediction ability than the linear models and good generalization. The optimized method used a radial basis function, which is in agreement with literature. Three other variables were adjusted: the capacity parameter, responsible for controlling the Gaussian function amplitude and the e- insensitive loss function. The LOO (leave-one-out) cross-validation for the training set showed 0.005011 for the root-mean-square error (RMS) and a coefficient of correlation close to one, indicating good fitting and consistency. With a minimum of 80% samples for training and 10% for verification, the model was capable to classify correctly the remaining samples. Three sample groups for tests had been separated and the net was capable to classify them correctly. Specific biomarkers for VUR were searched. Peptides that appeared in more than 70% of positive urine samples for VUR and less than 15% of negative samples were selected. MS2 spectra were acquired for these peptides and database search pointed to an IgG fragment as a possible candidate biomarker. However, the existence of a specific biomarker for VUR is not conclusive with the present data and a more thorough investigation must be pursued. Nevertheless, the peptidic maps inspected in this work carried enough information that allowed discrimination of two sample sets, one of them correctly associated with VUR

Page generated in 0.0342 seconds