1

Contribution à l'assurance qualité des dispositifs médicaux en implantologie orale : à propos de la précision du placement implantaire / Contribution to the quality assurance of medical devices in oral implantology : about the accuracy of the implant’s placement

Noharet, Renaud 25 June 2014 (has links)
L'assurance qualité est une discipline récente dans le domaine médical, d'autant plus en odontologie. Sa mise en oeuvre passe dans notre discipline essentiellement par l'application de règles d'exigences vis-à-vis des dispositifs médicaux utilisés au sein des cabinets dentaires. Les implants, les piliers, les prothèses implantaires mais également les guides chirurgicaux sont des exemples appliqués au domaine implantaire. Cette technique chirurgico-prothétique se doit d'être exécutée dans les meilleurs conditions avec une exigence optimale : chaque acte pouvant avoir des conséquences sur le patient et/ou l'avenir du traitement. Afin de répondre aux exigences d'assurance qualité du traitement implantaire, il semble que les guides chirurgicaux statiques puissent être un moyen afin d'améliorer le placement implantaire impactant donc la qualité de la thérapeutique mise en place. Dans un premier temps, les notions d'assurance qualité et des dispositifs médicaux sont remis en lumière, notamment au travers du filtre de l'implantologie orale. Ensuite, la qualité du traitement implantaire est discutée : des bases historiques jusqu'aux connaissances d'aujourd'hui. Il est important de maitriser l'évolution de cette technique et des outils associées afin de comprendre et donc d'utiliser les outils diagnostics et thérapeutiques à notre disposition aujourd'hui. Le dernier temps de ce travail constitue l'évaluation des outils actuels en implantologie (CFAO, stéréolithographie, chirurgie guide statique, informatique) au travers d'une étude sur sujets anatomiques. Cette étude évalue la précision du positionnement implantaire avec des guides dits conventionnels et des guides de chirurgie guidée statique. Cette précision est évaluée par comparaison des images préalables de planification et des examens tridimensionnels post-opératoires / The quality assurance is a recent discipline in the medical domain, all the more in odontology. Its implementation passes in our discipline essentially by the application of rules of requirements towards medical devices used within dental surgeries. Implants, abutments, implant’s prosthesis but also the surgical guides are examples applied to the domain. This surgico-prosthetic technique owes be executed in the best conditions with an optimal requirement: every act which can have consequences on the patient and/or the future of the treatment. To meet the requirements of quality assurance of the treatment, it seems that the static surgical guides can be a way to improve the placement of implants thus impacting on the quality of the organized therapeutics. At first, the notions of quality assurance and medical devices are handed in light, in particular through the filter of the oral implantology. Then, the quality of the treatment is discussed: historic bases until the knowledge of today. It is important to master the evolution of this technique and tools associated to understand and thus use tools diagnoses and therapeutic at our disposal today. The last time of this work establishes) the evaluation of the current tools implantologie (CAD-CAM, stereolithography, surgery guides static, IT) through a study on anatomical subjects. This study estimates the precision of the implant’s positioning with conventional said guides and guides of static guided surgery. This precision is estimated by comparison of the preliminary images of planning and the post operative threedimensional examinations
2

Nanosondes multimodales pour guider la chirurgie des carcinomatoses péritonéales d'origine ovarienne / Multimodal nanoprobe for guided surgery of ovarian peritoneal carcinomatosis

Mangeolle, Tristan 03 December 2018 (has links)
Les cancers ovariens se distinguent par leur faible incidence, associée à une mortalité élevée, et représente la cinquième cause de mortalité par cancer pour la population féminine. Cette mortalité est due principalement à l’absence de symptômes aux stades précoces des cancers ovariens, retardant leur diagnostic, majoritairement posé lorsqu’une carcinomatose péritonéale est installée. La cavité abdominale est alors envahie par de nombreuses métastases. Le traitement de référence est la chirurgie de cytoréduction complète et la chimiothérapie par voie intraveineuse. Lors de la chirurgie, le chirurgien doit inspecter la totalité de la surface de la cavité péritonéale, et éliminer des tumeurs de toutes tailles, mêmes submillimétriques. Faute de pouvoir détecter toutes les métastases, la cytoréduction est souvent partielle, avec pour conséquence une diminution des chances de guérison. Afin de guider le chirurgien et améliorer le pourcentage de cytoréduction complète, des sondes fluorescentes, conçues pour marquer spécifiquement les tumeurs, ont été développées. Malgré des résultats encourageants, ces sondes souffrent de nombreuses limitations en termes de brillance, de stabilité, et de modularité. Dans ce contexte, de nombreuses nanoparticules, capables de passer outre ces limitations, suscitent un grand intérêt. Parmi celles-ci, des nanocristaux semi-conducteurs, appelés quantum dots, se distinguent par une brillance exceptionnelle. Notre étude s’est basée sur ces quantum dots, associés à un agent de ciblage de référence pour les cancers ovariens, le folate. D’abord testées sur modèles cellulaires et tumoraux in vitro, ces nanoparticules ont démontré de bonnes capacités d’imagerie. Ces propriétés ont ensuite été expérimentées sur modèle murin de carcinomatose péritonéale. Enfin, la bioaccumulation des quantum dots restant un obstacle à leur application clinique, différentes alternatives ont été appliquées pour tenter d’obtenir leur excrétion / Ovarian cancers have a low incidence but a high mortality rate, making them the fifth cause of death by cancer for female population. This high mortality rate is associated with the absence of symptom at the early stage of ovarian cancer, often delaying the diagnosis to advanced stages, mainly peritoneal carcinomatosis. At this stage, metastases have already invaded the abdominal cavity. The reference treatment combines a complete cytoreduction surgery and intravenous chemotherapy. During the cytoreduction, the surgeon must inspect the whole peritoneal surface, and remove all of all sizes, even sub-millimetric. Because of the difficulty to detect and to remove every cancerous tissue, cytoreduction is frequently incomplete, thus reducing the recovery rate. To guide the surgeon and to increase the percentage of complete cytoreduction, fluorescent probes have been developed to target tumors specifically. Despite encouraging results, these probes suffer from many limitations such as low brightness, weak stability and cumbersome modularity. In this context, nanoparticles, that are able to outpass these limitations, have generated a growing interest. Among these nanoparticles, semiconductor nanocristals, called quantum dots, display an exceptional brightness. We investigated these quantum dots, associated with folate, a reference targeting agent for ovarian cancers. Firstly investigated on in vitro cellular and tumor model, folate targeted nanoparticles show encouraging imaging capabilities. These capabilites were also experimented on peritoneal carcinomatosis murine model. Finally, the main obstacle to quantum dot clinical application remains their bioaccumulation, therefore, different alternatives were explored to achieve excretion
3

Chirurgie guidée par fluorescence des fibrosarcome félin et développement et caractérisation d'un vecteur bi-fonctionnel pour le ciblage du cancer

Wenk, Christiane 17 December 2012 (has links) (PDF)
Actuellement, la chirurgie représente la première indication pour la thérapie du cancer. Néanmoins, la résection complète du tissu tumoral, la détection des micrométastases et la préservation des tissus sains pendant l'intervention représentent un enjeu majeur et influencent fortement le pronostic du patient. Les récents développements technologiques en imagerie pour la chirurgie guidée des cancers ont conduit à des résultats précliniques prometteurs et les premiers essais cliniques utilisant des traceurs non-spécifiques confirment déjà le potentiel de ces systèmes pour l'amélioration de la chirurgie. De plus, le diagnostic précoce des tumeurs, ainsi que le développement de thérapies ciblées sont également des axes majeurs de recherche en cancérologie. Dans ce contexte notre équipe a précédemment développé un vecteur synthétique ciblant un récepteur cellulaire l'intégrine αVβ3. Ce vecteur est constitué d'un châssis décapeptidique cyclique RAFT (Regioselectively Addressable Functionalized Template) et présentant deux domaines indépendants permettant de séparer les deux fonctions du vecteur. Sur un domaine, la fonction de ciblage est assurée par la présentation multivalente de ligands -RGD- spécifiques du récepteur. L'autre domaine du vecteur porte les molécules d'intérêt à vectoriser, agents thérapeutiques ou de détection pour l'imagerie médicale. Dans la première partie de ces travaux, nous avons évalué la combinaison de ce vecteur couplé à un fluorophore avec une sonde portative pour imager et guider le chirurgien pendant la chirurgie des fibrosarcomes spontanés chez le chat. Cette étude représente une preuve de concept pour la translation clinique chez l'homme. Les résultats ont montré que l'injection du traceur ne provoquait pas d'effets toxiques chez le chat et permettait un marquage spécifique de la tumeur avec un bon ratio tumeur/tissu sain, qui devrait améliorer la qualité de la résection tumorale en aidant le chirurgien à mieux délimiter les marges du tissu tumoral. Dans la seconde partie de ces travaux nous avons développé un nouveau vecteur bi-fonctionnel dérivé du RAFT-RGD. Au composé d'origine a été ajoutée une séquence peptidique clivable par la matrixmetalloprotease-9, une enzyme surexprimée dans la tumorigénèse. Cette molécule à fluorescence activable a montré une amélioration du ciblage tumoral in vitro et in vivo comparée au RAFT-RGD suggérant un effet additionnel lié au double ciblage. Ces résultats préliminaires encouragent la poursuite de sa caractérisation pour son potentiel de " pro-drug " mais également pour l'étude des interactions entre l'intégrine et l'environment tumoraux.
4

Optimisation et planification préopératoire des trajectoires en conditions statiques et déformables pour la chirurgie guidée par l'image / Preoperative path planning and optimization in static and deformable conditions for image-guided minimally invasive surgery

Hamze, Noura 21 June 2016 (has links)
En chirurgie mini-invasive guidée par l’image, une planification préopératoire précise des trajectoires des outils chirurgicaux est un facteur clé pour une intervention réussie. Cependant, une planification efficace est une tâche difficile, qui peut être considérablement améliorée en considérant différents facteurs contributifs tels que les déformations biomécaniques intra-opératoires, ou en introduisant de nouvelles techniques d'optimisation. Dans ce travail, nous nous concentrons sur deux aspects. Le premier aspect porte sur l'intégration de la déformation intra-opératoire dans le processus de planification de trajectoire. Nos méthodes combinent des techniques d'optimisation géométrique à base de simulations biomécaniques. Elles sont caractérisées par un certain niveau de généralité, et ont été expérimentées sur deux types d’interventions chirurgicales: les procédures percutanées pour l'ablation de tumeurs hépatiques, et la stimulation cérébrale profonde en neurochirurgie. Deuxièmement, nous étudions, mettons en œuvre, et comparons plusieurs approches d'optimisation en utilisant des méthodes qualitatives et quantitatives, et nous présentons une méthode efficace d'optimisation évolutionnaire multicritères à base de Pareto qui permet de trouver des solutions optimales qui ne sont pas accessibles par les méthodes existantes. / In image-guided minimally invasive surgery, a precise preoperative planning of the surgical tools trajectory is a key factor to a successful intervention. However, an efficient planning is a challenging task, which can be significantly improved when considering different contributing factors such as biomechanical intra-operative deformations, or novel optimization techniques. In this work, we focus on two aspects. The first aspect addresses integrating intra-operative deformation to the path planning process. Our methods combine geometric-based optimization techniques with physics-based simulations. They are characterized with a certain level of generality, and are experimented on two different surgical procedures: percutaneous procedures for hepatic tumor ablation, and in neurosurgery for Deep Brain Stimulation (DBS). Secondly, we investigate, implement, and compare many optimization approaches using qualitative and quantitative methods, and present an efficient evolutionary Pareto-based multi-criteria optimization method which can find optimal solutions that are not reachable via the current state of the art methods.
5

Imagerie fonctionnelle peropératoire naviguée pour l'optimisation de la chirurgie des tumeurs cérébrales / Intraoperative navigated functional imaging for brain tumor surgery optimization

Monge, Frédéric 02 December 2016 (has links)
Les gliomes sont des tumeurs cérébrales primitives représentant le deuxième cancer le plus fréquent chez l’enfant et la troisième cause de mortalité chez l’adulte jeune. Il a été démontré qu’une chirurgie d’exérèse tumorale permet d’augmenter la qualité et la durée de vie du patient, voir même dans certains cas, d’obtenir sa guérison. L’identification intraopératoire des résidus tumoraux permettrait au chirurgien de vérifier, in situ, la qualité de son geste d’exérèse. Une nouvelle modalité d’imagerie intraopératoire a été proposée comme solution pour détecter les tumeurs résiduelles. Elle se base sur l’utilisation d’une sonde nucléaire combinée à un système de localisation optique. Cette nouvelle modalité, appelée imagerie surfacique de positons (ISP), permet la génération d’images de la distribution surfacique d’un radiotraceur comme le 18 F − F DG d’une zone d’intérêt scannée. L’ISP n’étant actuellement pas utilisée en clinique, nous proposons pour la première fois une étude de faisabilité de son utilisation pour l’optimisation de la chirurgie des tumeurs cérébrales. Nous montrons les limites de l’utilisation potentielle de l’ISP dans un contexte neurochirurgical par des études expérimentales en considérant des facteurs intraopératoires pouvant influencer la qualité des images générées par le système. Les contributions présentées se concentrent sur trois axes. Dans un premier temps, nous souhaitons obtenir des images fonctionnelles d’ISP avec un temps de calcul faible. L’application de modèles d’acquisition aux mesures permettent d’améliorer la qualité des images, au détriment d’un temps de calcul élevé. Nous suggérons un nouveau modèle d’acquisition dédié au contexte intraopératoire, permettant l’amélioration de la résolution et du contraste des images pour un temps de calcul réduit. Un deuxième axe est dédié à l’étude de l’impact d’une acquisition intraopératoire sur les performances du système. Nous proposons l’estimation des paramètres intrinsèques de la sonde nucléaire utilisée et de l’influence de la hauteur du processus de scan sur leurs valeurs. Le dernier axe est consacré à la validation de modèles d’acquisition dans le contexte intraopératoire. Nous présentons une étude comparative des performances de modèles d’acquisition en considérant l’impact potentiel de la vitesse de scan durant l’acquisition. L’ensemble de ces travaux a contribué à l’étude de faisabilité de l’utilisation d’un système d’ISP en intraopératoire, proposée pour la première fois en neurochirurgie. / Gliomas are primitive brain tumors, which represent the second most frequent cancer among children and the third cause of death among young adult. It has been shown that resection surgery improves patient outcomes, leading to its cure for some cases. Intraoperative detection of residual tumor allows the surgeon to check the quality of its resection gesture. A new intraoperative imaging modality has been proposed as a solution to detect residual tumors. It relies on a nuclear probe associated with an optical localization system. This new modality, called positron surface imaging (PSI), generates images of the activity surface distribution of a 18 F based radiotracer of a scanned area of interest. Not used in clinical context yet, we proposed for the first time a feasibility study of its usage to optimize brain tumor surgery. We show limitations of the potential usage of PSI in neurosurgery through experimental studies, considering intraoperatives factors which may influence quality of generated images. Contributions in this study are presented on three axes. First, we want to generate PSI functional images with a low computational time. Acquisition models applied to measurements improve image quality at the cost of high computational time. We suggest a new acquisition model dedicated to intraoperative usage, allowing enhancement of spatial resolution and contrast of images for a low computational time. The second axis is dedicated to the study of the intraoperative acquisition impact on system performance. We propose to estimate the intrinsic parameters of nuclear probe and the study of scanning process on their values. Finally, we present the validation of acquisition models dedicated to intraoperative context. We show a comparative study of acquisition models performance considering potential impact of scanning speed process during acquisition. This work has contributed to the feasibility study of using an ISP system in the intraoperative context, proposed for the first time in neurosurgery.
6

Chirurgie guidée par fluorescence des fibrosarcome félin et développement et caractérisation d'un vecteur bi-fonctionnel pour le ciblage du cancer / Optical-guided surgery of the feline fibrosarcoma & Development and characterization of a bi-functional vector for cancer targeting

Wenk, Christiane 17 December 2012 (has links)
Actuellement, la chirurgie représente la première indication pour la thérapie du cancer. Néanmoins, la résection complète du tissu tumoral, la détection des micrométastases et la préservation des tissus sains pendant l'intervention représentent un enjeu majeur et influencent fortement le pronostic du patient. Les récents développements technologiques en imagerie pour la chirurgie guidée des cancers ont conduit à des résultats précliniques prometteurs et les premiers essais cliniques utilisant des traceurs non-spécifiques confirment déjà le potentiel de ces systèmes pour l'amélioration de la chirurgie. De plus, le diagnostic précoce des tumeurs, ainsi que le développement de thérapies ciblées sont également des axes majeurs de recherche en cancérologie. Dans ce contexte notre équipe a précédemment développé un vecteur synthétique ciblant un récepteur cellulaire l'intégrine αVβ3. Ce vecteur est constitué d'un châssis décapeptidique cyclique RAFT (Regioselectively Addressable Functionalized Template) et présentant deux domaines indépendants permettant de séparer les deux fonctions du vecteur. Sur un domaine, la fonction de ciblage est assurée par la présentation multivalente de ligands -RGD- spécifiques du récepteur. L'autre domaine du vecteur porte les molécules d'intérêt à vectoriser, agents thérapeutiques ou de détection pour l'imagerie médicale. Dans la première partie de ces travaux, nous avons évalué la combinaison de ce vecteur couplé à un fluorophore avec une sonde portative pour imager et guider le chirurgien pendant la chirurgie des fibrosarcomes spontanés chez le chat. Cette étude représente une preuve de concept pour la translation clinique chez l'homme. Les résultats ont montré que l'injection du traceur ne provoquait pas d'effets toxiques chez le chat et permettait un marquage spécifique de la tumeur avec un bon ratio tumeur/tissu sain, qui devrait améliorer la qualité de la résection tumorale en aidant le chirurgien à mieux délimiter les marges du tissu tumoral. Dans la seconde partie de ces travaux nous avons développé un nouveau vecteur bi-fonctionnel dérivé du RAFT-RGD. Au composé d'origine a été ajoutée une séquence peptidique clivable par la matrixmetalloprotease-9, une enzyme surexprimée dans la tumorigénèse. Cette molécule à fluorescence activable a montré une amélioration du ciblage tumoral in vitro et in vivo comparée au RAFT-RGD suggérant un effet additionnel lié au double ciblage. Ces résultats préliminaires encouragent la poursuite de sa caractérisation pour son potentiel de « pro-drug » mais également pour l'étude des interactions entre l'intégrine et l'environment tumoraux. / Cancer surgery is still the gold standard therapy in most cancers. Nevertheless, total tumor resection and metastasis detection while preserving healthy tissues represent a crucial point for further prognosis. Development of imaging technologies for intra-operative guided surgery provided promising results and efficient application in preclinical studies and first clinical trials using non-specific tracers already confirmed the improved out-come in surgery. Moreover early and precise diagnosis and targeted therapies are major domains of cancer research. In this context our team previously developed a synthetic vector based on a cyclic decapeptide scaffold RAFT (Regioselectively Addressable Functionalized Template) which allows the independent functionalizing of two domains: a targeting domain with multivalent RGD-ligand targeting the cell receptor integrin αVβ3, and a vehicle domain grafted with a pro-drug or an imaging agent. One part of this work consisted in the evaluation of the combination of this molecule carrying a fluorophore with a portable fluorescent imaging device for image-guided surgery of natural occurring feline fibrosarcomas. This study represents a proof of concept for further translation into human clinics. No toxic effects in cats after administration of the tracer could be reported. Furthermore the tumors were specifically labeled showing a good tumor-to-healthy tissue ratio. This should improve tumor resection by helping the surgeon to delineate tumor margins. In parallel we developed a bi-functinal derivative of the RAFT-RGD. Therefore we engrafted a peptide sequence flanked by two fluorophores, which is activatable by matrixmetalloprotease-9, an enzyme overexpressed in tumors. This molecule showed an improved tumor labeling in vitro and in vivo compared to the conventional RAFT-RGD, suggesting an additional effect of the double targeting. These preliminary results encourage further caracterisation for its potential as pro-drug vehicle, as well as for studying interactions between the integrin and the tumor environment.
7

Speed, precision and grip force analysis of human manual operations with and without direct visual input / Analyse de la précision, de la rapidité et de la force de gestes humains guidés par informations visuelles directes ou par image 2D/3D

Batmaz, Anil Ufuk 03 July 2018 (has links)
Le système perceptif d’un chirurgien doit s’adapter aux contraintes multisensorielles liées à la chirurgie guidée par l’image. Trois expériences sont conçues pour explorer ces contraintes visuelles et haptiques pour l’apprentissage guidé par l’image. Les résultats montrent que les sujets sont plus rapides et plus précis avec une vision directe. La stéréoscopie 3D n’améliore pas les performances des débutants complets. En réalité virtuelle, la variation de la longueur, largeur, position et complexité de l'objet affecte les performances motrices. La force de préhension appliquée sur un système robotique chirurgical dépend de l'expérience de l'utilisateur. En conclusion, le temps et la précision sont importants, mais la précision doit rester une priorité pour un apprenti. L'homogénéité des groupes d'étude est important pour la recherche sur la formation chirurgicale. Les résultats ont un impact direct sur le suivi des compétences individuelles pour les applications guidées par l'image. / Perceptual system of a surgeon must adapt to conditions of multisensorial constrains regard to planning, control, and execution of the image-guided surgical operations. Three experimental setups are designed to explore these visual and haptic constraints in the image-guided training. Results show that subjects are faster and more precise with direct vision compared to image guidance. Stereoscopic 3D viewing does not represent a performance advantage for complete beginners. In virtual reality, variation in object length, width, position, and complexity affect the motor performance. Applied grip force on a surgical robot system depends on the user experience level. In conclusion, both time and precision matter critically, but trainee gets as precise as possible before getting faster should be a priority. Study group homogeneity and background play key role in surgical training research. The findings have direct implications for individual skill monitoring for image-guided applications.