• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 45
  • Tagged with
  • 45
  • 45
  • 45
  • 12
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação físico-química de membranas de implantes mamários comercializados no Brasil. / Physical-chemical evaluation of breast implant membranes marketed in Brazil.

CALMON, Walfredo da Silva. 18 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-18T17:17:40Z No. of bitstreams: 1 WALFREDO DA SILVA CALMON - DISSERTAÇÃO PPG-CEMat 2014..pdf: 2111423 bytes, checksum: e64a02519d1c3b8005ac197552feadca (MD5) / Made available in DSpace on 2018-04-18T17:17:40Z (GMT). No. of bitstreams: 1 WALFREDO DA SILVA CALMON - DISSERTAÇÃO PPG-CEMat 2014..pdf: 2111423 bytes, checksum: e64a02519d1c3b8005ac197552feadca (MD5) Previous issue date: 2014-08-14 / Este trabalho tem por objetivo avaliar membranas de silicone que envolve o implante mamário preenchido com gel de silicone, no intuito de verificar a conformidade das suas propriedades. Como estratégia utilizou-se das técnicas de caracterização para analisar os parâmetros físico-químicos em três lotes diferentes de implante mamário. Os resultados experimentais encontrados foram comparados com valores referenciados em padrões estabelecidos em norma ou na literatura. Com isso, foi possível analisar alguns atributos que influenciam na qualidade desses implantes. Os resultados de microscopia por MO e MEV não detectaram anomalias nas superfícies das amostras. Foram detectados pelo ensaio de espectroscopia por EDS os elementos carbono, silício e oxigênio, como também identificados os metais ferro, cálcio, níquel e cromo nas amostras ensaiadas. O teste de alongamento de duas amostras não atendeu o requisito normativo. Conclui-se, portanto, que a integridade das membranas de silicone foi comprometida, por conta do seu comportamento mecânico, em duas das três amostras ensaiadas. / This work aims to evaluate silicon membranes surrounding the breast implant filled with silicone gel, in order to verify the conformity of its properties. As a strategy, we used the characterization techniques to analyze the physicochemical parameters in three different batches of breast implant. The experimental results were compared with values referenced in standard or standards established in the literature. Thus, it was possible to analyze some attributes that influence the quality of these implants. The results of OM and SEM microscopy did not detect anomalies in the surfaces of the samples. Were detected by testing the EDS spectra of carbon, silicon and oxygen elements, also identified as metals iron, calcium, nickel and chromium in the test samples. The stretching test two samples did not meet the regulatory requirement. Therefore, it is concluded that the integrity of the silicone membranes was compromised, because its mechanical behavior, in two of the three samples tested.
12

Fluidos inibidos para perfuração de folhelhos.

LUCENA, Danielly Vieira de. 24 January 2018 (has links)
Submitted by Gustavo Nascimento (gustavo.diniz@ufcg.edu.br) on 2018-01-24T12:44:30Z No. of bitstreams: 1 DANIELLY VIEIRA DE LUCENA – TESE PPGCEMAT 2018.pdf: 3908947 bytes, checksum: fcd5d2bc8ce65b22562ab8feb11da6ef (MD5) / Made available in DSpace on 2018-01-24T12:44:30Z (GMT). No. of bitstreams: 1 DANIELLY VIEIRA DE LUCENA – TESE PPGCEMAT 2018.pdf: 3908947 bytes, checksum: fcd5d2bc8ce65b22562ab8feb11da6ef (MD5) Previous issue date: 2014-07-21 / Estudar formações geológicas suscetíveis à hidratação se configura como um desafio por se tratar de um fenômeno responsável por cerca de 90% dos problemas relacionados com a perfuração de poços de petróleo, além de se tratar de um tema que pouco se conhece sobre os mecanismos que regem tal fenômeno e ainda, pela escassez de estudos voltados para a análise de diferentes produtos que evitem a ocorrência da problemática (inibidores) da hidratação. Deste modo, este trabalho objetivou o estudo e a avaliação da eficiência de fluidos de perfuração aquosos inibidos e isentos de cloro no controle da hidratação de formações de folhelhos de várias regiões do país. Para isto, foram estudadas treze amostras de folhelhos brasileiros e duas amostras de argilas bentoníticas. Inicialmente, realizou-se a caracterização de todas as amostras com a finalidade de identificar as mais suscetíveis à hidratação. Em seguida, foi realizado o estudo para selecionar a melhor concentração de inibidor para contenção da expansão de argilas reativas e a partir dos resultados foi estabelecida a concentração ótima de inibidor (20g/ 350mL de água). A partir disto, foram desenvolvidos fluidos de perfuração com quatro diferentes inibidores de argila expansiva (sulfato de potássio, acetato de potássio, citrato de potássio e cloreto de potássio) e determinados o pH, a densidade, as propriedades reológicas e de filtração. Foi também determinada a dispersibilidade dos fluidos desenvolvidos. A partir dos resultados, concluiu-se que foram desenvolvidos com êxito fluidos de perfuração que apresentam satisfatórios desempenhos reológicos e de filtração e propriedades inibitivas. Excelentes resultados em relação às taxas de dispersibilidade também foram obtidas. De modo geral, os resultados obtidos indicam que o inibidor citrato de potássio apresentou o melhor controle da reatividade de formações reativas e que o mesmo se constitui em um produto alternativo à substituição dos inibidores comerciais utilizados pela indústria. / To study geological formations susceptible to hydration is a challenge because it is a phenomenon responsible for about 90% of problems associated to the drilling of oil well, in addition it is a topic that deal with mechanisms little known governing this event and also due to the scarcity of the studies focused on the analysis of different products that avoid the occurrence of the hydration problems (inhibitors). In this way, the aim of this work was study the efficiency of the based water inhibited drilling fluids free of chlorine in the control of hydration of shale formation from various regions of the country. For this, it was studied thirteen samples of brazilian shales and two samples of bentonite clays. Firstly, it was done the characterization of the samples with the purpose of identifying the more susceptible to hydration. Then, it was studied the best concentration of the inhibitor to hinder the expansion of reactive clays and from these results it was established the best concentration of inhibitor (20g/350mL of water). After, it was developed drilling fluids with four different inhibitors of expansive clay (potassium phosphate, potassium acetate, potassium citrate and potassium chloride) and estimated the pH, density, rheological and filtration properties of these fluids. It is also estimated the dispersibility of the developed fluids. From the results, it was concluded that the fluids was developed with success and presented satisfactory rheological, filtration and inhibits properties. Excellent results with regard to the rates of dispersibility were also obtained. In general, the results indicated that the inhibitor potassium citrate presented the best control of reactivity of the formation and it constitutes an alternative to substitute the commercial inhibitors used by petroleum industry.
13

Especificações técnicas de dispositivos médicos: avaliação e sistematização de normas técnicas. / Technical requirements of medical devices: assessment and technical standards systematization.

SANTOS, Cleber Ferreira dos. 12 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-12T21:21:31Z No. of bitstreams: 1 CLEBER FERREIRA DOS SANTOS - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1300111 bytes, checksum: 651f20edaf5375c60e8b849a086f54dc (MD5) / Made available in DSpace on 2018-04-12T21:21:31Z (GMT). No. of bitstreams: 1 CLEBER FERREIRA DOS SANTOS - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1300111 bytes, checksum: 651f20edaf5375c60e8b849a086f54dc (MD5) Previous issue date: 2014-10-07 / A regulação sanitária brasileira para dispositivos médicos, aí entendida os materiais de uso em saúde, equipamentos médicos e kit de diagnóstico de uso in vitro, largamente utilizados em ambientes hospitalares e até domiciliares, deve definir os princípios essenciais de segurança e eficácia que esses produtos devem cumprir. De forma a atender a esses mandamentos busca-se verificar o quanto tais dispositivos cumprem com os requisitos estabelecidos em normas e padrões nacionais ou internacionais. O universo de dispositivos médicos é imenso, estimado em mais de oito mil itens e os padrões atualmente disponíveis a esse grupo de dispositivos se estima em mais de 800 normas, o que dificulta a identificação das especificações relacionadas a aspectos sanitários e de segurança. Portanto, se constitui um grande desafio para a ANVISA, responsável pelo controle e também pelos laboratórios de avaliação desses produtos, promover esse controle. Este trabalho se propõe a apresentar um modelo de sistematização para o estabelecimento de especificações técnicas pertinentes ao universo de produtos para a saúde na perspectiva do conhecimento das propriedades dos materiais e das caracterizações atualmente propostas. Essa proposição permitirá que as ações de vigilância sanitária sejam focadas nos pontos críticos do controle sanitário de cada um ou grupo de dispositivos médicos, aumentando a efetividade deste controle e dando transparência à ação do órgão regulador. / Medical device’s Brazilian regulation, compresis the materials for use in healthcare, medical equipment and in vitro diagnostic, widely used in hospitals and even home environments, should contain essential principles of safety and efficacy that these products have to meet. In order to meet these commandments we seek to verify how such devices comply with the requirements in national or international standards. The universe of medical devices is huge, estimated at over eight thousand items, and the standards currently available to this group of devices, which is estimated at more than 800 standards, making it difficult to identify the health aspects related specification and safety. This it is a major challenge for the ANVISA, responsible for controlling and also for the evaluation of these products by laboratories, promote this control. This paper aims to present a systematic model for the establishment of the relevant universe of health products in terms of knowledge of material properties and characterizations of the currently proposed technical specifications. This proposition will allow health surveillance activities been focused on the critical points of the sanitary control of each or group of medical devices, increasing the effectiveness of this control and giving transparency to the action of the Regulatory Agency.
14

Avaliação do efeito da radiação ultravioleta sobre polietileno de ultra-alto peso molecular usado implantes para artroplastia. / Evaluation of the effect of ultraviolet radiation on ultra high molecular weight polyethylene used implants for arthroplasty.

RIBEIRO, Márcia Cristina de Moraes Reis. 13 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-13T17:46:55Z No. of bitstreams: 1 MÁRCIA CRISTINA DE MORAES REIS RIBEIRO - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1739612 bytes, checksum: 483de315f077aaf3a1be5bb9bddc6639 (MD5) / Made available in DSpace on 2018-04-13T17:46:55Z (GMT). No. of bitstreams: 1 MÁRCIA CRISTINA DE MORAES REIS RIBEIRO - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1739612 bytes, checksum: 483de315f077aaf3a1be5bb9bddc6639 (MD5) Previous issue date: 2014-07-16 / O polietileno de ultra alto peso molecular (PEUAPM) é um polímero com excelentes propriedades físicas e mecânicas tendo como mais notáveis a sua inércia química, a lubricidade, resistência impacto e resistência a abrasão. Exibe um papel relevante no sucesso na Artroplastia Total de Joelho (ATJ) e Artroplastia Total de Quadril (ATQ). A Artroplastia se caracteriza pela substituição da articulação natural por uma articulação artificial. As articulações artificiais são formadas por um conjunto de componentes, sendo fabricados de matéria prima metálica ou cerâmica e um componente, normalmente feito em PEUAPM, que é interposto entre componentes metálicos. Alguns fatores contribuem para um maior desgaste do componente de polietileno. Os componentes fabricados em polietileno PEUAPM não possuem fotoestabilizadores. E em inspeções realizadas em fabricantes e distribuidores destes produtos foi observado que durante seu processamento fabril e comercialização eles não são adequadamente protegidos da iluminação direta. As características consideradas importantes para o desempenho in vitro destes dispositivos estão definidas em normas técnicas, mas muitas destas normas somente recomendam determinados requisitos considerados importantes do ponto de vista técnico. Atualmente a área de materiais de uso em saúde trabalha em regulamentos que visam instituir os requisitos mínimos para registro de implantes ortopédicos. Desta forma, este trabalho propôs avaliar as possíveis alterações de componentes fabricados em polietileno de ultra alto peso molecular utilizados em procedimentos cirúrgicos de artroplastia e joelho e quadril, exposto a radiação ultravioleta. O trabalho foi dividido em 4 grupos: grupo 1 (material não exposto a UV); grupo 2 (material exposto a UV por 1h); grupo 3 (material exposto a UV por 24h) e grupo 4 (material exposto a UV por 48h). Todas as amostras foram caracterizadas por Difração de Raio X (DRX), Espectroscopia de Absorção de Infravermelho por Transformada de Fourier (FTIR), Microscopia Ótica (MO), Microscopia Eletrônica de Varredura (MEV) com mapeamento por EDS e Microscopia de Força Atômica (AFM) com o intuito de avaliar as possíveis degradações do PEUAPM submetidos a radiação UV. Os resultados demonstraram que a exposição do polímero a radiação UV em todos os tempos testados neste trabalho promoveu alterações nas amostras, pois foi observado, principalmente, nos ensaios de DRX e EDS que ocorreu respectivamente, um discreto aumento da cristalinidade do material e diminuição no percentual de oxigênio. Desta forma, pode-se concluir que o aumento da cristalinidade pode, pela ação da radiação UV, afetar nas propriedades do material contribuindo para o aumento do desgaste e diminuição do tempo de vida útil do implante. / The polyethylene, ultra high molecular weight (UHMWPE) is a polymer with excellent physical and mechanical properties with the most notable its chemical inertness, lubricity, impact resistance and abrasion resistance. Displays a relevant role in the successful Total Knee Arthroplasty (TKA) and Total Hip Arthroplasty (THA). The arthroplasty is characterized by replacement of the natural joint with an artificial joint. Artificial joints are formed by a set of components, being manufactured from metal or ceramic raw material and a component normally done in UHMWPE, which is interposed between the metal components. Some factors contribute to increased wear of the polyethylene component. Components manufactured in polyethylene UHMWPE not have photostabilizers. And inspections on manufacturers and distributors of these products was observed that during its industrial processing and marketing they are not adequately protected from direct light. Characteristics considered important for the in vitro performance of these devices are set in technical standards, but many of these standards only recommend certain requirements considered important from a technical standpoint. Currently the area of materials for use in healthcare working on regulations that seek to establish the minimum requirements for registration of orthopedic implants. Thus, this study aimed to evaluate the possible changes of components manufactured in polyethylene, ultra high molecular weight used in surgical procedures and knee arthroplasty and hip, exposed to ultraviolet radiation. The work was divided into 4 groups: group 1 (material not exposed to UV); group 2 (material exposed to UV for 1 h); group 3 (material exposed to UV for 24 h) and group 4 (material exposed to UV for 48 h). All samples were characterized by X-Ray Diffraction (XRD), Absorption Spectroscopy Fourier Transform Infrared (FTIR), optical microscopy (OM), scanning electron microscopy (SEM) with EDS mapping and Atomic Force Microscopy (AFM) in order to evaluate the possible degradation of UHMWPE subjected to UV radiation. The results showed that exposure of the polymer to UV radiation at all times tested in this study modified the samples, it was observed mainly in the experimental XRD and EDS which occurred respectively a slight increase in crystallinity and decrease in the percentage oxygen. Thus, it can be concluded that the increase in crystallinity can by the action of UV radiation, affect the material properties contributing to increased wear and reduced useful life of the implant.
15

Filme de quitosana para liberação controlada de colchicina para tratamento de carcinoma basocelular. / Chitosan film for controlled release of colchicine for treatment of basal cell carcinoma.

BRAZ, Adriana da Costa. 13 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-13T18:27:12Z No. of bitstreams: 1 ADRIANA DA COSTA BRAZ - DISSERTAÇÃO PPG-CEMat 2014..pdf: 2523605 bytes, checksum: 90e198ea98d95b535e91044abaf7e15f (MD5) / Made available in DSpace on 2018-04-13T18:27:12Z (GMT). No. of bitstreams: 1 ADRIANA DA COSTA BRAZ - DISSERTAÇÃO PPG-CEMat 2014..pdf: 2523605 bytes, checksum: 90e198ea98d95b535e91044abaf7e15f (MD5) Previous issue date: 2014-12-12 / O Carcinoma basocelular é o câncer mais comum do mundo, e apesar da sua evolução muitas vezes benigna, com altas taxas de cura, algumas vezes nos deparamos com casos mais agressivos, invasivos, destrutivos e de difícil controle. É sabido que já houve avanços terapêuticos para estes casos específicos, a exemplo do Vismodegib, entretanto o uso desta droga ainda é uma realidade distante para nossos pacientes brasileiros que se expõe a índices elevados de radiações solares, na maioria trabalhadores rurais de baixa renda e com grande dificuldade a acessibilidade ao sistema público de saúde. Por isso, o presente trabalho sugere uma alternativa para o controle das formas graves do carcinoma basocelular, através da produção de um filme de quitosana dopado de colchicina substância sabidamente antimitótica e com evidência clínica já citada na literatura no carcinoma basocelular, por via transdérmica por liberação controlada da droga que permita mantê-la em um nível sérico contínuo, suficiente para sua ação antimitótica, causando morte seletiva das células tumorais, diminuindo ou extirpando esses tumores, com custos mais acessíveis, pois é uma droga de baixo custo, melhorando consequentemente a morbidade da doença e a qualidade de vida destes pacientes. E os resultados obtidos através das caracterizações apresentaram membranas com variações de cristalinidade (por DRX) de acordo com o processo de reticulação. Por FTIR pode-se observar certa interação entre o fármaco e os grupos amina da quitosana. Pelas microscopias ótica e eletrônica, pode-se observar que o acréscimo de fármaco proporcionou alguma rugosidade a membrana. Também pelas microscopias verificou-se a reticulação não homogênea da superfície da membrana. Por EDS não se verificou nenhum elemento estranho a estrutura da quitosana e do fármaco. Por medida do ângulo de molhabilidade pode-se verificar aumento do perfil hidrofílico da membrana por adição do fármaco, perfil este que foi modificado pelo processo de reticulação. A partir do ensaio de citotoxicidade pode-se constatar que a membrana apresenta certa citotoxicidade. Este resultado demonstra também o potencial da membrana de quitosana em liberar o fármaco, considerando que a membrana apenas de quitosana não apresenta toxicidade em meio biológico, sendo a toxicidade observada no ensaio decorrente do fármaco liberado. / Basal cell carcinoma is the most common cancer in the world, and despite its evolution often benign, with high cure rates, sometimes we are faced with more aggressive, invasive cases, destructive and difficult to control. It is known that there have been advances in treatment for these specific cases, such as the Vismodegib, however this drug is still a distant reality for our Brazilian patients who are exposed to high levels of solar radiation in most rural workers from low-income, great difficulty accessibility to the public health system. Therefore, this study suggests an alternative for the control of severe forms of basal cell carcinoma, through the production of a chitosan film doped colchicine known antimitotic substance and with clinical evidence already mentioned in the literature in basal cell carcinoma, transdermally for release controlled drug that allows keep at a steady serum level, enough for their antimitotic, causing selective killing of tumor cells, reducing or extirpating these tumors, with more affordable because it is an inexpensive drug, consequently improving morbidity the disease and the quality of life of these patients. And the results obtained from the characterization showed membranes crystallinity variations (XRD) according to the crosslinking process. By FTIR one can observe some interaction between the drug and amino groups of chitosan. Through optical and electronic microscopy, it can be seen that addition of drug has provided some roughness to the membrane. Also by microscopy verified the inhomogeneous crosslinking of the membrane surface. EDS there was no foreign object the structure of chitosan and the drug. By measuring the wetting angle can be checked increase the hydrophilic profile of the drug by adding the membrane, this profile has been modified by the crosslinking process. From the cytotoxicity assay can be seen that the membrane has some cytotoxicity. This result also demonstrates the potential of chitosan membrane to release the drug, whereas only chitosan membrane shows no toxicity in biological medium, with the toxicity observed in this trial due to the released drug.
16

Avaliação e caracterização de dispositivos intrauterinos utilizados comercialmente. / Evaluation and characterization of intrauterine devices used commercially.

BEZERRA, Maria das Neves Guedes Cavalcanti. 16 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-16T19:27:36Z No. of bitstreams: 1 MARIA DAS NEVES GUEDES CAVALCANTI BEZERRA - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1961977 bytes, checksum: 48356976ff3729c606e179600ae156ad (MD5) / Made available in DSpace on 2018-04-16T19:27:36Z (GMT). No. of bitstreams: 1 MARIA DAS NEVES GUEDES CAVALCANTI BEZERRA - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1961977 bytes, checksum: 48356976ff3729c606e179600ae156ad (MD5) Previous issue date: 2014-05-30 / A pesquisa teve como objetivo realizar análise comparativa entre os contraceptivos DIU`s utilizados comercialmente. Dentro desse objetivo buscou-se: propor bases comparativas entre composição dos DIU TCu 380 A e endoceptivos hormonais; determinar a possível oxidação dos DIU‟s de Cobre; determinar o tipo de polietileno utilizado em ambos os DIU‟s. A pesquisa foi desenvolvida no Laboratório de Avaliação e Desenvolvimento de Biomateriais do Nordeste - CERTBIO, localizada na Unidade Acadêmica de Engenharia de Materiais, na Universidade Federal de Campina Grande/UFCG. Foram utilizadas duas amostras de Dispositivos Intrauterinos usualmente utilizados, descritos adiante: DIU TCu 380 A e Endoceptivo Medicamentos. Foram avaliadas as composições químicas dos DIU‟s e o tipo de polietileno, através das seguintes técnicas: Microscopia Óptica (MO), Microscopia Eletrônica de Varredura (MEV/EDX), Espectroscopia na Região de Infravermelho com Transformada de Fourier (FTIR), Difração de Raios X (DRX) e Calorimetria Exploratória Diferencial (DSC). Pode-se comprovar também a partir da análise de EDS a presença do sulfato de bário em ambos os DIU‟s, onde o mesmo é utilizado para tornar o DIU visível em raios X. Comprovou-se a presença de silício e oxigênio no tronco do DIU com levonorgestrel indicando ser o mesmo constituído por uma polidimetilsiloxano como informado pelo fabricante. Pode-se comprovar pela análise de FTIR, que o material formador dos corpos principais de ambos os DIU‟s era polietileno pela análise do espectograma. A análise de DRX corroborou com os resultados obtidos na análise de FTIR, que indicavam que o material dos dispositivos se tratava de polietileno, apresentando um espectograma típico de PE. Pode-se comprovar também, que o fio e os anéis do DIU TCu 380 A eram compostos por cobre. A análise de DSC mostrou ser o polietileno constituinte de ambos os DIU‟s, um polietileno de baixa densidade (LDPE). Diante do exposto podese concluir que ambos os DIU‟s possuem corpo formado por polietileno de baixa densidade, porém, possuem processamentos diferentes, onde a estrutura do DIU levonorgestrel apresenta superfície com acabamento mais refinado em relação ao DIU TCu 380 A. / The research aims to perform comparative analysis between contraceptives - IUD`s used commercially. Within this objective we sought: to propose a comparative basis between composition of TCu 380A IUD and Hormonal Endoception; determine the possible oxidation of copper IUDs; determining the type of polyethylene used in both IUD's. The research was conducted at the Laboratory of Biomaterials Evaluation and Development of the Northeast - CERTBIO, located in the Academic Unit of Materials Engineering, Federal University of Campina Grande / UFCG. TCu 380A and Sterile Endoception: two samples of intrauterine devices commonly used, as described below were used. Chemical compositions of IUDs and type of polyethylene were evaluated using the following techniques: Optical Microscopy (OM), Scanning Electron Microscopy (SEM / EDX) Spectroscopy in the Region with Infrared Fourier Transform Spectroscopy (FTIR), X-Ray Diffraction (XRD) and Differential Scanning Calorimetry (DSC). It can also prove from the EDS analysis the presence of barium sulphate in both IUD's, where it was used to make the IUD visible on x-rays proved the presence of silicium and oxygen in the stem of the IUD levonorgestrel indicating that it comprises a polydimethylsiloxane as reported by the manufacturer. Can be proved with FTIR analysis of the forming material of the principal of both bodies was polyethylene IUD‟s for examining the spectrogram. XRD analysis corroborated the results obtained with FTIR analysis of the material indicated that the devices it was polyethylene having a typical PE spectrogram. One can also show that the wire rings and the TCu 380 were composed of copper. The DSC analysis showed to be a constituent of both polyethylene IUDs Low Density Polyethylene (LDPE). Given the above it can be concluded that both IUDs have bodies formed of low density polyethylene, but have different processing, where the structure of the IUD levonorgestrel has finer surface finish compared to TCu 380 A.
17

Avaliação das propriedades fisico-químicas das luvas de policloreto de Vinila (PVC) sob regime de vigilância sanitária. / Evaluation of the physico-chemical properties of polyvinyl chloride gloves (PVC) under health surveillance.

MARTINS, Priscilla Consigliero de Rezende. 17 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-17T12:40:12Z No. of bitstreams: 1 PRISCILLA CONSIGLIERO DE REZENDE MARTINS - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1527771 bytes, checksum: cc67203373e93ed35f44365878e7d5cb (MD5) / Made available in DSpace on 2018-04-17T12:40:12Z (GMT). No. of bitstreams: 1 PRISCILLA CONSIGLIERO DE REZENDE MARTINS - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1527771 bytes, checksum: cc67203373e93ed35f44365878e7d5cb (MD5) Previous issue date: 2014-10-28 / A partir de 1980, em virtude do surgimento da AIDS/HIV, o Centers for Disease Control and Prevention (CDC) preconizou as “Precauções Universais”, e então as luvas passaram a ser utilizadas amplamente nos serviços de saúde. Popularizado o uso das luvas, começaram a surgir os primeiros relatos de reações alérgicas induzidas pelo látex. A partir de então, as empresas desenvolveram substitutos sintéticos para o látex, tais como PVC. Em 2011, foi publicada a Resolução RDC nº 55 que estabeleceu os requisitos mínimos de identidade e qualidade para as luvas cirúrgicas e luvas para procedimentos não cirúrgicos de borracha natural, de borracha sintética, de mistura de borrachas natural e sintética e de policloreto de vinila. Desta forma, este trabalho propôs a caracterização e a avaliação das luvas para procedimentos não cirúrgicos produzidas de policloreto de vinila, no intuito de verificar se as luvas estão em conformidade em relação à Norma - ABNT NBR ISO 11193-2. Para isso foram avaliadas 3 diferentes marcas comerciais de luvas para procedimentos não cirúrgicos de PVC cadastradas na ANVISA, sendo caracterizadas por DRX, FTIR, MEV, EDS, molhabilidade, e avaliadas quanto às dimensões, à impermeabilidade, e à força de ruptura e alongamento na ruptura conforme metodologia da norma. No FTIR observaram-se quantidades de grupamentos químicos semelhantes em todas as amostras analisadas. O MEV demonstrou a morfologia da superfície lisa e plana das Luvas D e E, enquanto a Luva S apresentou superfície texturizada e uniforme. Evidenciouse que as amostras das luvas de policloreto de vinila ensaiadas não atenderam aos requisitos mecânicos estabelecidos na norma vigente, principalmente no que diz respeito ao alongamento mínimo da ruptura de 350%. Diante do resultado, sugere-se o programa de monitoramento e avaliação da conformidade com um maior número de amostras de luvas de policloreto de vinila, assim como a posterior avaliação da Resolução RDC 55, de 4 de novembro de 2011, para avaliar a necessidade da inclusão das luvas de policloreto de vinila no escopo de certificação compulsória. / During the mid-1980´s, due to the emergence of AIDS, the Centers for Disease Control and Prevention (CDC) introduction the "Universal Precautions" and gloves began to be widely used in health services. The use of gloves was popularize in medical and surgical procedures, and reports of allergic reactions induced by latex began to emerge. Since then, companies have developed synthetic substitutes for latex, such as PVC. In 2011, was published the Resolution RDC nº 55 which established the minimum requirements of identity and quality for surgical and exam gloves made of natural rubber, synthetic rubber, a mixture of natural and synthetic rubbers and polyvinyl chloride. Thus, this study proposes the characterization and evaluation of exam vinvyl gloves, in order to check if the gloves meet the requirements of the standard ABNT NBR ISO 11193-2. Three different brands of regularized exam gloves at ANVISA were evaluated, being characterized by XRD, FTIR, SEM, EDS, Wetting Test, as well as evaluated the size, impermeability, and tensile properties according to the standard methodology. It was observed similar quantities of chemical groups in all samples analyzed by FTIR. The SEM morphology showed a smooth flat surface of the gloves D and E, while the S glove presented textured and uniform surface. It was shown that samples of vinyl gloves tested did not meet the standard´s mechanical requirements, especially the breaking elongation´s requirement of 350%. A conformity assessment with a larger sample of vinyl gloves it is suggested, as well as a further review of the Resolution RDC 55/2011 to assess the need for inclusion of vinyl gloves in the scope of mandatory certification.
18

Estudo do processo de recozimento na reciclagem de vidros para fabricação de produtos utilitários. / Study of the annealing process in the recycling of glass for the manufacture of commercial products.

DIAS, Vanúcia Santos. 18 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-18T15:31:59Z No. of bitstreams: 1 VANUCIA SANTOS DIAS - DISSERTAÇÃO PPG-CEMat 2014..pdf: 3639913 bytes, checksum: 915ca6c2f3b8eced104eb3bd31c33dd3 (MD5) / Made available in DSpace on 2018-04-18T15:31:59Z (GMT). No. of bitstreams: 1 VANUCIA SANTOS DIAS - DISSERTAÇÃO PPG-CEMat 2014..pdf: 3639913 bytes, checksum: 915ca6c2f3b8eced104eb3bd31c33dd3 (MD5) Previous issue date: 2014-08-29 / Um dos grandes problemas sanitários está na disposição final dos resíduos gerados pela população e pelas indústrias. No estado da Paraíba, são coletados diariamente 2.754 toneladas de resíduos sólidos urbanos, destes 30,9% têm destinação final em aterros sanitários, 36,9% destinam-se para aterros controlados e 32,2% têm como destino final os lixões. O reaproveitamento do vidro indica 100% de reprocessamento. Além de ser 100% reciclável, o vidro, quando reaproveitado, resulta em redução do impacto ambiental e ainda contribui para diversificação da fabricação de produtos e para diminuição dos custos finais de sua produção. Este trabalho objetiva estudar o processo de recozimento de resíduos vítreos, visando contribuir para o desenvolvimento de uma tecnologia social de reciclagem de vidros para as trabalhadoras do CAVI - Associação de Catadores e Recicladores de Vidros e outros Materiais. Para isso foram utilizados resíduos de vidros planos e ocos submetidos a cinco processos de fusão e recozimento com diferentes níveis de temperatura, empregando técnicas de reciclagem de vidro a quente (vitrofusão e termoformado). Foram utilizados moldes de cerâmica para os estudos iniciais e de gesso para a confecção dos corpos de prova. A resistência após o recozimento foi analisada por meio de ensaios de impacto, em que pode ser constatado que as amostras submetidas ao tratamento térmico estudado apresentaram maior resistência ao impacto quando comparadas às amostras que não receberam tratamento térmico durante o processo de fusão. As fraturas obtidas após os ensaios foram analisadas macroscopicamente. / One of the major health problems is the disposal of waste generated by the population and industries. In the state of Paraíba, are collected daily 2,754 tons of municipal solid waste, 30.9% of these have final disposal in landfills, 36.9% intended to controlled landfills and 32.2% have a final destination landfills. Recycling of glass indicates 100% reprocessing. Besides being 100% recyclable glass, when reused, resulting in reduced environmental impact and still contributes to diversification of manufacturing products and to decrease the final cost of its production. This work aims to study the process of annealing of glassy waste, aiming to contribute to the social development of a recycling technology for glass workers CAVI - Association of Collectors and Recyclers of Glass and other Materials. For this waste flat glass and hollow undergone five mergers and annealing with different temperature levels were used, employing techniques of recycling glass hot (fusing and slumping). Ceramic molds for the initial studies and gypsum for the manufacture of test specimens were used. The resistance after annealing was examined by impact tests, it can be seen that the samples subjected to the heat treatment study had higher impact resistance compared to samples which received no heat treatment during the melting process. The fractures obtained after the tests were analyzed macroscopically.
19

Desenvolvimento de compósitos utilizando lodo da indústria têxtil na produção de concreto não estrutural.

ALTIDIS, Marina Elizabeth Dias. 02 February 2018 (has links)
Submitted by Gustavo Nascimento (gustavo.diniz@ufcg.edu.br) on 2018-02-02T13:11:21Z No. of bitstreams: 1 MARINA ELIZABETH DIAS ALTIDIS - TESE PPGCEMAT 2014.pdf: 3254058 bytes, checksum: a79dcea655b13895244c80449cb4813d (MD5) / Made available in DSpace on 2018-02-02T13:11:21Z (GMT). No. of bitstreams: 1 MARINA ELIZABETH DIAS ALTIDIS - TESE PPGCEMAT 2014.pdf: 3254058 bytes, checksum: a79dcea655b13895244c80449cb4813d (MD5) Previous issue date: 2014-08-29 / O interesse pela utilização de resíduos industriais, tais como lodo tem crescido como alternativa tanto na redução do volume desse passivo ambiental quanto na obtenção de um produto a ser utilizado na construção civil. Este trabalho tem como objetivo desenvolver e avaliar as propriedades físico-mecânicas de concretos formados a partir do uso de lodo da indústria têxtil, visando sua aplicação na construção civil. O lodo têxtil foi seco em estufa a 110ºC por vinte e quatro horas e triturado em moinho para adquirir granulometria adequada e em seguida submetido às seguintes análises: termogravimetria, análise térmica diferencial, espectroscopia vibracional de absorção no infravermelho, difração de raios-X, análise química, lixiviação, solubilização e microscopia óptica. Foram confeccionados corpos de prova de concreto utilizando os traços 1:3 e 1:4 com teores de substituição de 0 %, 3 %, 5 % e 7 % de lodo no agregado miúdo, com 7, 28 e 60 dias de cura e realizaram-se os seguintes ensaios: abatimento do tronco do cone, de resistência à compressão axial, resistência à compressão diametral, absorção, índice de vazios, massa especifica, microscopia óptica, microscopia eletrônica de varredura, lixiviação e solubilização. Os resultados das caracterizações do lodo têxtil apresentaram a compatibilidade química e estabilidade térmica suficiente para sua incorporação no concreto, entretanto verificou um alto teor de matéria orgânica. Já o ensaio de lixiviação classificou o lodo têxtil como resíduo perigoso, devido o extrato lixiviado ultrapassar o limite para os metais ferro e manganês. Já nos corpos de provas os ensaios de lixiviação e solubilização mostraram que os metais encontram-se encapsulados no concreto com teores de até 7 % de lodo têxtil. Nas microscopias realizadas nos corpos de provas de concretos, verificou-se a pouca interação do lodo com os constituintes do concreto. Já a absorção de água apresentou uma tendência de aumento, quando cresceu a quantidade de lodo têxtil, mas os valores ficaram abaixo de 10 %, podendo ser considerado de boa qualidade. No que se refere aos resultados de resistência à compressão ocorreu uma diminuição desta com o teor de lodo têxtil. No traço 1:3 com teores de até 7 % de lodo e no traço 1:4 com até 5 % de lodo o concreto foi considerado moderado, e para o traço 1:4 com 7 % de lodo foi classificado como concreto não estrutural. / Interesting in the use of industrial waste, such as sludge has grown both as an alternative in reducing the volume of this environmental liability as in getting a product to be used in civil building. This work aims to develop and evaluate physical and mechanical properties of concrete formed from the use of textile industry sludge, for its application in civil building. The textile sludge was dried at 110°C for twenty-four hours and milled in a grinder to get proper particle size and then subjected to the following tests: thermogravimetry, differential thermal analysis, vibrational infrared absorption spectroscopy, X-ray diffraction,chemical analysis, leaching, solubilization and optical microscopy. Concrete specimens were fabricated using the ratios 1:3 and 1:4 under levels of sludge substitution of 0 %, 3 %, 5 % and 7 % in the small aggregate, with7, 28 and 60 days of curing and performed the following tests: cone trunk reduction, compressive strength, tensile splitting strength, absorption, void ratio, specific gravity, optical microscopy, scanning electron microscopy, and leaching. The results of the textile sludgecharacterizations showed the chemical compatibility and thermal stability sufficient for its incorporation in concrete, however it was found a high content of organic matter. Again, leaching test rated the textile sludge dangerousand, because the extract leaching exceed the limit for the metals iron and manganese. The sample tests regarding solubilizatio and leaching tests showed that metals are encapsulated in concrete with levels of up to 7 % of textile sludge. In microscopy performed on test samples of concrete, there was a little interaction with the sludge constituents of the concrete. The water absorption presented increase trend when increased the amount of textile sludge, but the values were below 10 % and can be considered good quality. Regarding theresults of compressive strength occurred decrease relatedto the textile sludge content. On the ratio 1:3, with sludge levels up to 7 %, and the ratio 1: 4 up to 5 % of suldge level, the the concrete was considered moderate, and the ratio 1:4 up to 7 % of sludge, the concrete was classified as non structural.
20

Avaliação das características físico-químicas e morfológicas de preservativos masculinos comercializados no Brazil. / Evaluation of physical-chemical and morphological characteristics of male condoms commercialized in Brazil. / 評估巴西商業化的男用安全套的理化和形態特徵。 / Evaluación de las características físico-químicas y morfológicas de preservativos masculinos comercializados en el Brasil. / Évaluation des caractéristiques physico-chimiques et morphologiques des préservatifs masculins commercialisés au Brésil.

CUNHA, Thiago Rezende Pereira. 09 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-09T18:32:06Z No. of bitstreams: 1 THIAGO REZENDE PEREIRA CUNHA - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1352465 bytes, checksum: 3481c73a8eaa2b12ea683840100503a9 (MD5) / Made available in DSpace on 2018-04-09T18:32:06Z (GMT). No. of bitstreams: 1 THIAGO REZENDE PEREIRA CUNHA - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1352465 bytes, checksum: 3481c73a8eaa2b12ea683840100503a9 (MD5) Previous issue date: 2014-10-28 / Os preservativos masculinos são os principais instrumentos de proteção contra doenças sexualmente transmissíveis e controle de natalidade no mundo e são produzidos, principalmente, a partir do látex natural. Desde os anos 80, com o aumento significativo na utilização de preservativos, a indústria desenvolveu novos modelos com diferentes tamanhos, espessuras e aromas. Com o aumento de relatos de reações alérgicas induzidas pelo látex foram desenvolvidos modelos de preservativos fabricados a partir de outros materiais, como o poliuretano. Estudos sugerem que o poliuretano pode representar uma boa alternativa ao látex, apesar de não possuírem as mesmas propriedades físicas e químicas. Desde 2002 os preservativos de látex são certificados compulsoriamente pela Anvisa e o Inmetro. Atualmente, essa certificação segue os requisitos estabelecidos pela RDC 62/2008. Desta forma, este trabalho objetivou verificar se os requisitos mínimos exigidos para os dispositivos de látex podem ser aplicados aos de poliuretano. Para isso, foram realizados os ensaios de dimensões, espessura, determinação da capacidade volumétrica e pressão de estouro, verificação de orifícios e da integridade da embalagem primária, ensaios descritos na RDC 62/2008, além de microscopia eletrônica de varredura, difratometria de raio-x, espectroscopia de energia dispersiva e ensaios mecânicos. Os resultados dos ensaios demonstraram as diferenças nas propriedades físico-químicas dos materiais e que os ensaios da norma não podem ser aplicados na íntegra aos preservativos de poliuretano. De acordo com os resultados pode-se concluir que é necessário estabelecer valores de referência para certificação dos preservativos de poliuretano, considerando sua maior resistência e menor elasticidade em comparação ao látex. / Male condoms are the main instruments of protection against sexually transmitted diseases and birth control in the world and are produced mainly from natural rubber. Since the 80s, with the significant increase in the use of condoms, the industry has developed new models with different sizes, thicknesses and tastes. With the increase in reported allergic reactions induced for latex, models of condoms made from other materials such as polyurethane have been developed. Studies suggest that polyurethane can be a good alternative to latex, despite not having the same physical and chemical properties. Since 2002 latex condoms are compulsorily certified by ANVISA and INMETRO. Currently this certification follows the requirements established by RDC 62/2008. Thus, this study aimed to determine if the minimum requirements for rubber devices can be applied to polyurethane. For this, testing of dimensions, thickness, determining the volumetric capacity and bursting pressure, check for holes and integrity of primary packaging, the tests described in RDC 62/2008 were performed, and also scanning electron microscopy, x-ray diffraction, energy dispersive spectroscopy and mechanical testing. The test results showed the differences in the physicochemical properties of materials and the testing of the standard cannot be applied in full to polyurethane condoms. According to the results it can be concluded that it is necessary to establish standards for certification of polyurethane condoms, considering its greater elasticity and lower resistance compared to natural rubber.

Page generated in 0.1405 seconds