Spelling suggestions: "subject:"ciência e engenharia dde materiais"" "subject:"ciência e engenharia dee materiais""
41 |
Avaliação de fios de Polipropileno comerciais para sutura visando a construção de um processo de certificação sanitária. / Evaluation of commercial polypropylene yarn for suture aiming the construction of a sanitary certification process.NASCIMENTO, Alessandro Ferreira do. 05 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-05T19:25:23Z
No. of bitstreams: 1
ALESSANDRO FERREIRA DO NASCIMENTO - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1766148 bytes, checksum: 9952d3c1d40fa2b65189b5ac5fa3540f (MD5) / Made available in DSpace on 2018-04-05T19:25:23Z (GMT). No. of bitstreams: 1
ALESSANDRO FERREIRA DO NASCIMENTO - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1766148 bytes, checksum: 9952d3c1d40fa2b65189b5ac5fa3540f (MD5)
Previous issue date: 24-07-16 / Os fios para sutura cirúrgica são considerados produtos médicos invasivos utilizados
para aproximação de tecido biológico e, devido ao contato com a pele, vasculatura e
outros tecidos, são considerados um produto crítico. O presente trabalho propõe a
avaliação de um dos fios com maior número de queixas técnicas notificadas à
ANVISA, o fio de sutura de polipropileno, que é empregado em diversas
intervenções cirúrgicas que requerem material inerte ao tecido e suporte mecânico,
assim, uma avaliação da natureza físico-química do material empregado em
amostras comerciais é importante para nortear um processo de certificação sanitária
visando minimizar o risco aos pacientes. O fio de polipropileno foi adotado como
modelo de análise , sendo escolhido o fio de número cirúrgico 0(zero) com 75cm de
comprimento; foram selecionadas 4 amostras de fios de sutura de polipropileno de
acordo com o padrão de notificações recebidas pela área de tecnovigilância da
ANVISA como modelo para a execução de ensaios de difração de raio X,
microscopia ótica, microscopia eletrônica de varredura com mapeamento por EDS,
FTIR, microscopia de força atômica, análise termogravimétrica e ensaios
mecânicos. Os resultados apresentados demonstraram perfis distintos nos aspectos
morfológicos e mecânicos dos fios de sutura selecionados, suscitando a construção
de um conjunto de análises distintas daquelas atualmente preconizadas para o
registro desses produtos, assim como o estabelecimento de um processo
certificador que seria realizado harmonizando parâmetros de ensaios mecânicos e
caracterização morfológica dos fios de sutura, capaz de assegurar maior
homogeneidade nos fios de sutura disponíveis comercialmente. / The suture threads are considered invasive medical products used for approximation
of biological tissue and, due to contact with the skin, vasculature and other tissues,
are considered a critical product. This paper proposes an evaluation of one of the
wires with the largest number of technical complaints notified to ANVISA, the suture
of polypropylene, which is used in various surgical procedures which require inert
mechanical support to the tissue and thus a substantive assessment of the nature
physical chemistry of the material used in commercial samples is important to guide
a process of health certification in order to minimize the risk to patients. The
polypropylene suture was used as the analysis model, being selected the surgical
wire number 0 (zero) to 75cm long; 4 samples of polypropylene sutures were
selected according to the pattern of notifications received by the area of technical
surveillance of ANVISA as a model for the implementation of the testing of X-ray
diffraction, optical microscopy, scanning with EDS mapping by electron microscopy,
FTIR, atomic force microscopy, thermal analysis and mechanical testing. The results
presented demonstrated distinct profiles on the morphological and mechanical suture
wires of selected aspects, prompting the construction of a set of analyzes of those
currently recommended for the registration of these products, as well as the
establishment of a certification process that would be done by harmonizing testing
parameters morphological and mechanical characterization of the suture capable of
ensuring a greater homogeneity in the commercially available suture threads.
|
42 |
Análise da degradação e do poder calorífico de resíduos sólidos urbanos. / Analyse de la dégradation et du pouvoir calorifique des déchets dans les solides urbains. / Analysis of the degradation and calorific power of waste to urban solids (garbage) / Análisis de la degradación y del poder calorífico de residuos sólidos urbanos.QUEIROZ, Abílio José Procópio. 06 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-06T21:19:15Z
No. of bitstreams: 1
ABÍLIO JOSÉ PROCÓPIO QUEIROZ - DISSERTAÇÃO PPG-CEMat 2014..pdf: 5068589 bytes, checksum: 8bb50d0449bc510a3c3f1cd6c496edd3 (MD5) / Made available in DSpace on 2018-04-06T21:19:15Z (GMT). No. of bitstreams: 1
ABÍLIO JOSÉ PROCÓPIO QUEIROZ - DISSERTAÇÃO PPG-CEMat 2014..pdf: 5068589 bytes, checksum: 8bb50d0449bc510a3c3f1cd6c496edd3 (MD5)
Previous issue date: 2014-08-27 / O gerenciamento de resíduos sólidos urbanos, atualmente feito de forma
errônea na maior parte das cidades brasileiras, acelerando a degradação do
meio ambiente, e a busca por fontes alternativas de energia, para suprimento
da crescente demanda, são problemáticas atualmente discutidas e que
precisam de soluções urgentes. Este estudo identifica características físicoquímicas
de RSU, depositados em biorreator que simula as condições de um
aterro sanitário, e avalia a possibilidade de utilização de um material que ainda
é descartado como combustível para geração de energia. O objetivo geral foi
avaliar a degradação e o poder calorífico de resíduos sólidos urbanos. As
amostras analisadas por FTIR, DRX, TG e DSC foram coletadas em lisímetro
construído na Universidade Federal de Campina Grande e preenchido de RSU
previamente caracterizados. Os ensaios de FTIR indicaram a predominância
orgânica dos materiais presentes nas amostras de RSU. Pelos difratogramas
de raios-X o principal pico e comum a todas amostras foi de quartzo,
justificando a presença do solo de recobrimento das amostras. As amostras de
RSU apresentaram baixa estabilidade térmica, ocorrendo degradação entre a
temperatura ambiente e 1000 ºC, sendo visível e aceitável afirmar que ocorrem
em cinco etapas de perda associadas à volatilização dos solventes (água e
álcoois), à queima de celulose, borracha natural, matéria orgânica putrescível e
materiais plásticos, bem como dos óxidos formados durante o processo. Pelas
curvas DSC foram identificadas uma reação endotérmica, associada à primeira
perda de massa, e quatro reações, duas endotérmicas e duas exotérmicas,
ligadas às perdas da degradação dos componentes orgânicos. Os 348.402
kg/dia de RSU produzidos em Campina Grande, amostrados pela massa do
biorreator, possuem um poder calorífico médio de 3.744,86 kcal/kg e poderiam
ser gerados 1.518.551,40 kW.h/dia de energia térmica ou 303.710,28 kW.h/dia
de energia elétrica, com eficiência de conversão de 20%. / The management of municipal solid waste, currently done wrongly in most
Brazilian cities, accelerating the degradation of the environment, and the search
for alternative energy sources to supply the growing demand, are currently
discussed and problems that need solutions urgent. This study identifies
physical and chemical characteristics of MSW deposited in bioreactor that
simulates the conditions of a landfill site, and evaluates the possibility of using a
material that is still dismissed as fuel for power generation. The overall objective
was to evaluate the degradation and the calorific value of municipal solid waste.
The samples analyzed by FTIR, XRD, TG and DSC were collected in lysimeter
constructed at the Federal University of Campina Grande and filled MSW
previously characterized. FTIR tests indicated a predominance of the organic
materials present in samples of MSW. By X-ray diffraction main peak and
common to all samples was quartz, which explains the presence of the soil
cover of the samples. MSW samples had poor thermal stability, degradation
occurring between room temperature and 1000 ºC, being visible and acceptable
state that occurs in five steps loss associated volatilization of the solvents
(water and alcohol), the combustion of cellulose, natural rubber, putrescible
organic matter and plastics, as well as the oxides formed during the process.
DSC curves for an endothermic reaction associated with the first weight loss
and four reactions, two endothermic and exothermic two linked to the loss of the
degradation of the organic components have been identified. The 348,402
kg/day of USW produced in Campina Grande, sampled by mass of the
bioreactor have an average calorific value of 3,744.86 kcal/kg, and could be
generated 1,518,551.40 kW.h/day of thermal energy or 303,710. 28 kW.h/day of
electricity, with conversion efficiency of 20%.
|
43 |
Avaliação de implantes de polimetilmetacrilato (PMMA) para procedimentos de bioplastia. / Evaluation of polymethylmethacrylate implants for bioplasty procedures. / Evaluación de los implantes de polimetilmetacrilato para procedimientos de bioplastia. / Évaluation des implants de polyméthylméthacrylate pour les procédures de bioplastie.DOLGHI, Sandro Martins. 09 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-09T18:16:27Z
No. of bitstreams: 1
SANDRO MARTINS DOLGHI - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1349252 bytes, checksum: 7e20e2840dc2a5d2e873cd9b77ed0100 (MD5) / Made available in DSpace on 2018-04-09T18:16:27Z (GMT). No. of bitstreams: 1
SANDRO MARTINS DOLGHI - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1349252 bytes, checksum: 7e20e2840dc2a5d2e873cd9b77ed0100 (MD5)
Previous issue date: 2014-12-19 / O culto à beleza está em evidência no Brasil e no mundo, levando ao crescente
aumento de técnicas e procedimentos para corrigir defeitos estéticos e minimizar os
efeitos do envelhecimento. Diversas substâncias preenchedoras com fluidos de alta
viscosidade ou partículas de polímeros em suspensão têm sido utilizadas em larga
escala em procedimentos cosméticos e correção de lipodistrofia de pacientes HIV
positivos, submetidos à terapia antirretroviral de alta atividade. O uso de
polimetilmetacrilato (PMMA) como substância de preenchimento dérmico tem
crescido vertiginosamente, assim como o número de reações adversas decorrentes
de seu uso. O PMMA vem sendo utilizado, amplamente como matéria prima na
fabricação de diversos dispositivos e produtos médicos desde a década de 40,
especialmente em função de sua biocompatibilidade, entretanto, ainda há carência
de informações e estudos sobre migração e resposta inflamatória das substâncias
comercializadas no Brasil para fins de preenchimento dérmico. Este trabalho teve
como objetivo avaliar as características físico-químicas de implantes de PMMA
comercializados no Brasil para procedimentos de bioplastia, em três apresentações
comerciais do produto com diferentes concentrações, visando delimitar limites
aceitáveis para fins de registro destes produtos na Agência Nacional de Vigilância
Sanitária (Anvisa), com foco na segurança sanitária. As amostras foram
caracterizadas por Difração de Raios X (DRX), Espectroscopia na região do
infravermelho com transformada de Fourier (FTIR), Microscopia Eletrônica de
Varredura (MEV), Espectroscopia por Energia Dispersiva de Raios X (EDS), análise
de Calorimetria Exploratória Diferencial (DSC), caracterização por Microscopia
Óptica (MO). A técnica de DRX mostrou comportamento semicristalino do PMMA.
Com a técnica de FTIR constatou-se os grupos funcionais presentes nos implantes.
Por meio das técnicas de MO e MEV foi possível perceber a não homogeneidade em
relação ao tamanho das microesferas de PMMA. Pôde-se concluir com os resultados
de DSC que o pico endotérmico aumentou de acordo com as variações de
concentração do PMMA. A partir dos dados obtidos neste trabalho constata-se que o
consumidor está sujeito a riscos, visto que a irregularidade das superfícies e
variações nos tamanhos das microesferas pode ocasionar reações adversas, em
função da fagocitose das microesferas com tamanho inferior a 20 μm. O crescente
uso das técnicas de preenchimento com implantes de PMMA, bem como sua
indicação para uso em demais especialidades da medicina, o coloca como material a
ser ainda amplamente estudado nas mais diversas aplicações do produto na área
médica. / The cult of beauty is in evidence in Brazil and in the world, leading to increasing
techniques and procedures to correct aesthetic defects and minimize the effects of
aging. Several dermal fillers with high viscosity or polymer particles in suspension
fluids have been used in large scale in cosmetic procedures and lipodystrophy
correction of HIV-positive patients undergoing HAART activity. The use of
polymethylmethacrylate (PMMA) as dermal filler substance has grown dramatically,
and the number of adverse reactions arising from its use. PMMA has been used
widely as a raw material in manufacturing various medical devices and products
since the 40s, especially due to its biocompatibility, however, there is still a lack of
information and studies on migration and inflammatory response of substances
marketed in Brazil dermal filler purposes. This study aimed to evaluate the physical
and chemical characteristics of PMMA implants sold in Brazil for bioplasty
procedures in three commercial presentations of the product with different
concentrations, in order to delimit acceptable limits for registration of these products
at ANVISA, with focus on security health. The samples were characterized by X-ray
Diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), Scanning Electron
Microscopy (SEM), Spectroscopy Energy Dispersive X-ray (EDS) analysis of
Differential Scanning Calorimetry (DSC), characterized by Optical Microscopy (OM).
The XRD technique showed semi-crystalline behavior of PMMA. FTIR technique
found the functional groups present on the implants. Through OM and SEM
techniques we saw the inhomogeneity relative to the size of the PMMA
microspheres. One can conclude from the results of the DSC endothermic peak
increased in accordance with changes in the concentration of PMMA. From the data
obtained in this study it appears that the consumer is subject to risks as uneven
surfaces and variations in size of the microspheres can cause adverse reactions,
depending on the phagocytosis of microspheres with size less than 20 microns. The
increasing use of technical fill with PMMA implants, as well as indications for use in
other specialties of medicine, places it as material to be still widely studied in various
product applications in the medical field.
|
44 |
Influência da Poli (Ɛ-Caprolactona) e de copolímeros funcionalizados no desempenho de blendas com matriz de poli (ácido-lático). / Influence of poly (Ɛ-caprolactone) and functionalized copolymers on the performance of poly (lactic acid) matrix blends. / Influence du poly (Ɛ-caprolactone) et des copolymères fonctionnalisés sur la performance des mélanges de matrices poly (acide lactique). / Influencia de la Poli (Ɛ-Caprolactona) y de copolímeros funcionalizados en el desempeño de mezclas con matriz de poli (ácido-láctico).SILVA, Taciana Regina de Gouveia. 06 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-06T20:12:23Z
No. of bitstreams: 1
TACIANA REGINA DE GOUVEIA - TESE PPG-CEMat 2014..pdf: 4953603 bytes, checksum: ea581c261908041111cd0d411a551545 (MD5) / Made available in DSpace on 2018-04-06T20:12:23Z (GMT). No. of bitstreams: 1
TACIANA REGINA DE GOUVEIA - TESE PPG-CEMat 2014..pdf: 4953603 bytes, checksum: ea581c261908041111cd0d411a551545 (MD5)
Previous issue date: 2014-08-28 / Capes / Os polímeros derivados do petróleo têm provocado impactos ambientais devido
ao descarte inadequado. Uma alternativa para esse problema é a utilização de
polímeros biodegradáveis ou a produção de blendas a partir destes polímeros.
Neste trabalho, foram preparadas blendas de poli (ácido lático) - PLA, poli (caprolactona)
- PCL, com três copolímeros diferentes: EMA, E-GMA e o EMAGMA
que são copolímeros de etileno-acrilato de metila, etileno-metacrilato de
glicidila e o terpolímero etileno-acrilato de metila-metacrilato de glicidila,
respectivamente. As composições utilizadas para as blendas foram as
seguintes: PLA/PCL (90/10), PLA/PCL (80/20), PLA/Copolímeros (90/10) e
PLA/PCL/Copolímeros (80/10/10). Estas foram preparadas por fusão em uma
extrusora de rosca dupla corrotativa e, em seguida, moldadas por injeção sob a
forma de corpos de prova de tração, impacto e HDT. Todas as composições
foram caracterizadas por: ensaios mecânicos de tração e impacto, temperatura
de distorção térmica - HDT, calorimetria exploratória diferencial - DSC, difração
de raios X - DRX, análise térmica dinâmica-mecânica - DMTA, espectroscopia na região do infravermelho por transformada de Fourier - FTIR, microscopia
eletrônica de varredura - MEV, reometria de torque, ensaio reológico e
reometria capilar. As propriedades mecânicas apresentaram redução nos
valores do módulo e da resistência à tração e um aumento no alongamento e
na resistência ao impacto para todas as composições quando comparadas com
o PLA puro, com destaque para as composições que continham o copolímero
EMA-GMA. A HDT não apresentou mudanças significativas para as diferentes
composições em comparação com o PLA puro. O comportamento térmico e
termomecânico foi avaliado por DSC e por DMTA e foi possível observar a
transição térmica das blendas. Por DRX foi possível observar as fases
cristalinas das blendas de PLA. A morfologia da superfície de fratura observada
por MEV ilustrou que ocorreram mudanças significativas em função da
composição. Os resultados de reometria de torque não apresentaram mudanças significativas no comportamento do PLA, enquanto que os
resultados obtidos no ensaio reológico ilustraram aumento no módulo de
armazenamento em todas as composições. A partir do ensaio de reometria
capilar foi visto que houve redução da viscosidade aparente e da tensão de
cisalhamento sob altas taxas de cisalhamento para todas as composições. / The polymers derived from petroleum have caused environmental impacts due
to improper disposal. An alternative to this problem is the use of biodegradable
polymers or blends production from these polymers. In this work, blends of poly
(lactic acid) - PLA, poly (-caprolactone) - PCL, were prepared with three
different copolymers: EMA, E-GMA and EMA-GMA are copolymers the
ethylene-methyl acrylate, ethylene-glycidyl methacrylate and terpolymer
ethylene-methyl acrylate-glycidyl methacrylate respectively. The compositions
used in the blends were as follows: PLA/PCL (90/10) PLA/PCL (80/20) PLA/
Copolymer (90/10) and PLA/PCL/Copolymer (80/10/10). These were prepared
by melting in an extruder twin screw co-rotating and then injection molded in the
form of specimens tensile, impact and HDT. All compositions were
characterized by: mechanical tensile and impact , heat distortion temperature -
HDT, differential scanning calorimetry - DSC, X-ray diffraction - XRD, dynamic
mechanical thermal analysis – DMTA, spectroscopy in the infrared region by
transform Fourier - FTIR, scanning electron microscopy - SEM, torque
rheometer, rheological testing and capillary rheometer. The mechanical
properties showed reduced values of modulus and tensile strength and an
increase in elongation and impact resistance for all compositions when
compared with pure PLA, especially for compositions containing copolymer
EMA-GMA. The HDT showed no significant changes for the different
compositions compared with pure PLA. The thermal and thermomechanical
behavior was evaluated by DSC and DMTA and it was possible to observe the
thermal transition of the blends. XRD was possible to observe the crystalline
phases of the blends of PLA. The morphology of the fracture surface was
observed by SEM illustrated that significant changes as a function of
composition. The torque rheometer results showed no significant change in the
behavior of PLA, while the rheological test results illustrate the increase in
storage modulus in all compositions. From the test capillary rheometer was seen that there was a reduction in the apparent viscosity and shear stress at
high shear rates for all compositions.
|
45 |
Avaliação das características fisico-químicas de géis de fluor de uso odontológico profissional. / Evaluation of the physicochemical characteristics of fluoride gels for professional dental use. / Evaluación de las características fisicoquímicas de geles de fluor de uso odontológico profesional. / Évaluation des caractéristiques physico-chimiques des gels fluorés à usage dentaire professionnel.CARDOSO, Gina Maria Coelho de Souza. 05 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-05T19:46:22Z
No. of bitstreams: 1
GINA MARA COELHO DE SOUZA CARDOSO - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1501065 bytes, checksum: e02311753867e448c8a544a0dd42857f (MD5) / Made available in DSpace on 2018-04-05T19:46:22Z (GMT). No. of bitstreams: 1
GINA MARA COELHO DE SOUZA CARDOSO - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1501065 bytes, checksum: e02311753867e448c8a544a0dd42857f (MD5)
Previous issue date: 2014-07-17 / O uso clínico de géis de flúor para aplicação tópica por profissionais está indicado
para prevenção e tratamento de cárie e erosão dental devido à capacidade de
interação com o processo de desmineralização-remineralização da matriz mineral do
dente. O objetivo geral deste trabalho foi avaliar géis com flúor para remineralização
dentária de uso tópico profissional quanto às características físico-químicas
especificadas nos registros concedidos pela ANVISA. Foi verificada a existência de
quinze (15) registros válidos na ANVISA, referentes a dezesseis (16) produtos de gel
com flúor de uso tópico odontológico. Quanto a estes produtos, são oito (8) géis de
flúor neutro e oito (8) géis de flúor acidulado. Todos os produtos possuem em sua
composição fluoreto de sódio e o polímero mais utilizado para formação do gel é
hidroxietil celulose, conforme declarado nos processos de registro na ANVISA. Em
60% dos processos de registro válidos há informação sobre o pH dos produtos. Com
o levantamento realizado em março de 2014 nas dentais do Distrito Federal (DF),
verificou-se a comercialização de dois produtos de um mesmo fabricante, sendo um
gel de flúor neutro e um gel de flúor acidulado. Para a caracterização físico-química,
foram adquiridos nove frascos de 200 mL de gel de flúor comercializados no DF: três
de gel de flúor acidulado dentro da validade, três de gel flúor acidulado fora da
validade e três de gel de flúor neutro. Estes produtos foram avaliados pelas
seguintes técnicas: Microscopia eletrônica de varredura (MEV), Espectroscopia de
energia dispersiva de raios X (EDS), espectroscopia na região de infravermelho com
transformada de Fourier (FTIR), calorimetria exploratória diferencial (DSC), análise
termogravimétrica (TGA) e avaliação do potencial hidrogeniônico (pH). Os elementos
químicos identificados na análise por EDS estão condizentes com a composição
química dos produtos declarados pelo fabricante à ANVISA. Os resultados de FTIR
não demonstraram alterações significativas entre as amostras avaliadas. Foram
verificados resultados diferentes entre as amostras, nos ensaios de TGA e DSC, isto
provavelmente está relacionado com a desidratação das amostras e a formação de
aglomerados. Os produtos avaliados a 25°C apresentaram resultados satisfatórios
quanto ao pH. Mais pesquisas sobre a caracterização físico-química para o gel de
flúor tópico de uso profissional odontológico são necessárias para embasar o
desenvolvimento de normas técnicas específicas. / Clinical use of fluoride gels for topical application by professionals is indicated for
prevention and treatment of dental caries and dental erosion due to the ability to
interact with the process of demineralization - remineralization of tooth mineral
matrix. The general objective of this work was to evaluate the physicochemical
characteristics of topical gels for professional dental remineralization specified in the
records granted by ANVISA. There were fifteen (15) valid records, relating to sixteen
(16) products of fluoride gel use dental topic has been verified. As for these products,
there were eight (8) neutral fluoride gels and eight (8) acidulated fluoride gels. All
products contain in their composition sodium fluoride and the most used polymer for
gel formation is hydroxyethyl cellulose. All acidulated fluoride gels have in their
composition 1.23 % fluorine ions and all neutral fluoride gels contain 2 % NaF in its
composition, as stated in the registration process at ANVISA. In 60 % of valid
registration process there was information about the pH of the product. In the survey
conducted in March 2014 in dental stores at Federal District (DF), it was observed
the marketing of two products from the same manufacturer, being one neutral fluoride
gel and one gel of acidulated fluoride. For physicochemical characterization, nine
bottles of 200 ml of fluoride gel were acquired in DF: three of acidulated fluoride gel
within the validity, three of acidulated fluoride gel out of date and three of neutral
fluoride gel. These products were evaluated by the following techniques: Scanning
Electron Microscopy (SEM), Energy Dispersive X-ray Spectrometry (EDS), Fourier
Transform Infrared Spectrometer (FTIR), Differential Scanning Calorimetry (DSC),
Thermogravimetry (TG) and evaluation of the hydrogen potential (pH). The chemical
elements identified by EDS analysis, in regions without clusters and with clusters of
dehydrated samples, are consistent with the chemical composition of the products
declared by the manufacturer to ANVISA. The FTIR outcomes showed no significant
changes among analyzed samples. Different results among samples were observed
during DSC and TGA tests, this is probably related to dehydration of the samples and
the formation of agglomerates. More studies about the physicochemical
characteristics of topical gels for professional dental remineralization are needed to
support the development of specific technical standards.
|
Page generated in 0.507 seconds