• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 114
  • Tagged with
  • 114
  • 114
  • 52
  • 46
  • 44
  • 35
  • 34
  • 19
  • 16
  • 15
  • 14
  • 14
  • 14
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Avaliação da resistência adesiva entre um cimento resinoso e ligas para metalo-cerâmica submetidas a dois diferentes condicionamentos de supefície

Andreatta Filho, Osvaldo Daniel [UNESP] 12 December 2005 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-12Bitstream added on 2015-01-26T13:30:14Z : No. of bitstreams: 1 000436713.pdf: 7731647 bytes, checksum: 9b7aadb95aa028efeda85c7c4760387c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a hipótese de que diferentes condicionamentos de superfície de três ligas para próteses metalo-cerâmica (Ouro - Degudent U – Degussa; Níquel-Cromo - Wiron 99, Bego; Titânio - Rematitan, Dentaurum) não alteram os valores de resistência adesiva com um cimento resinoso. Vinte blocos de cada liga com dimensões de 5x5x5mm foram fundidos e divididos em dois subgrupos de 10 blocos e condicionados com os seguintes tratamentos de superfície: TRAT. 1 (Primer) – jateamento com partículas de óxido de alumínio 110µm (Al2O3) + Alloy Primer (Kuraray, CO) e TRAT. 2 (Cojet)– jateamento com partículas de sílica com o sistema Cojet (3M/ESPE) + Silano ESPE-Sil (3M/ESPE). Os blocos condicionados de cada grupo foram cimentados com Panavia F (Kuraray, CO) a blocos de resina composta ClearfilTM AP-X (Kuraray, CO) sob carga constante de 750g por 10 minutos. Foram determinados, portanto, seis grupos experimentais constituídos por conjuntos formados pela liga, cimento e resina composta. Estes foram cortados em uma máquina de corte obtendo-se por bloco cimentado 4 amostras com dimensões de 10x1x1mm sendo que a superfície adesiva apresentou aproximadamente 1mm2 de área. O teste de microtração foi realizado em máquina de testes universal (EMIC) com célula de carga de 10kgf e velocidade de 1mm/min. Cada grupo foi representado por quarenta amostras, entretanto cada grupo apresentou 10 valores médios de resistência adesiva em MPa (n=10), sendo que cada valor foi proveniente da média obtida a partir dos valores individuais das quatro amostras de cada conjunto de blocos cimentados. Os valores de resistência adesiva e os desvios-padrão (MPa) para os grupos foram : G1: 7,33 ± 1,93d; G2: 13,35 ± 2,18 c G3: 23,56 ± 6,5 b; G4:42,6 ± 5,84 a; G5: 26,17 ± 1,94 b; G6: 44,30 ± 2,3 a. Os dados de resistência adesiva foram analisados estatisticamente pelo teste de .... / The aim of this study is to evaluate the hypothesis that different conditionings of surface of three dental alloys (Gold - Degudent U – Degussa; Nickel-chromium - Wiron 99, Bego; Titanium - Rematitan, Dentaurum) they do not modify the values of bond strength with a resin cement. Twenty blocks of each alloy with dimensions of 5x5x5mm were cast and divided in two subgroups of 10 blocks that were conditioned with the following surface treatments: TRAT. 1 – sandblasting with particles of oxide of aluminum 110μm (Al2O3) + Alloy Primer (Kuraray, CO) and TRAT. 2 - sandblasting with particles of oxide of silica with Cojet-Sand (3M/ESPE) + Silane (ESPE-SIL). The conditioned blocks of each group were luted with Panavia F (Kuraray, CO) to composite resin blocks of ClearfilTM AP-X (Kuraray, CO) under constant load of 750g for 10 minutes. Six experimental groups were constituted by sets formed by the alloy, cement and composite resin. The sets were split up in a mechanical lathe obtaining by block 4 samples with dimensions of 10x1x1mm and the adhesive surface with approximately 1mm2. The microtensile test was accomplished in an universal test machine (EMIC) with cell of load of 10kgf and crosshead speed of 1mm/min. Each group was represented by forty samples, however each group presented 10 means values of bond strength MPa (n=10), obtained from the mean of the individual values of the four samples of each cemented blocks. Means and standard deviation of bond strength (MPa) were: G1: 7.33 ± 1.93d; G2: 13.35 ± 2.18 c G3: 23.56 ± 6.5 b; G4:42.6 ± 5.84 a; G5: 26.17 ± 1.94 b; G6: 44.30 ± 2.3 a. The data of bond strength were analyzed by the analysis of variance test (ANOVA) and Tukey test, p<0.05. The results indicated that surface treatment 2 (Cojet) increased the bond strength between the resin cement and alloys. The smallest values of bond strength were obtained with gold alloy, independent of ....
62

Resistência de união, índice de remanescente adesivo e avaliação da presença de esmalte sobre a base de braquetes após descolagem: estudo in vitro

Tonetto, Mateus Rodrigues [UNESP] 31 January 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-31Bitstream added on 2015-03-03T12:07:30Z : No. of bitstreams: 1 000806368_20170131.pdf: 301415 bytes, checksum: d5befa6999fc213abc6df3b415c547ce (MD5) Bitstreams deleted on 2017-02-03T10:35:38Z: 000806368_20170131.pdf,. Added 1 bitstream(s) on 2017-02-03T10:36:28Z : No. of bitstreams: 1 000806368.pdf: 1361304 bytes, checksum: 376e0f7c264d2cb783ea56336927e782 (MD5) / Este estudo in vitro avaliou a resistência de união e índice de remanescente adesivo (IRA) de um braquete modificado colado com cimento resinoso auto-adesivo, e verificou a presença de substrato de esmalte na base do braquete após a descolagem. Foram selecionados noventa dentes bovinos e distribuidos aleatoriamente (n=15) de acordo com os grupos: G1 – Braquetes metálicos colados com Transbond™ XT; G2 – Braquetes metálicos do sistema APC colados sem procedimento adesivo adicional; G3 - Braquetes metálicos do sistema APC colados com sistema adesivo auto-condicionante; G4 - Braquetes metálicos colados com RelyX U200; G5 – Braquetes modificados (alteração na base do braquete Victory™) colados com Transbond™ XT; G6 - Braquetes modificados colados com RelyX U200. Foi realizado ensaio de resistência ao cisalhamento dos braquetes e após a remoção dos mesmos, o IRA foi observado em lupa estereoscópica (30x) (Carl Zeiss, Brasil) e as bases dos braquetes foram verificadas quanto a presença de resíduos de esmalte dental (Ca) por meio de EDS. Os resultados mostraram que o maior valor médio de resistência ao cisalhamento foi encontrado no grupo 1 (14,33 MPa) e o menor valor médio de resistência ao cisalhamento foi no grupo 4 (2,36 MPa). O IRA foi avaliado e os grupos que utilizaram o ácido fosfórico ou primer autocondicionante (grupos 1, 2, 3 e 5) apresentaram adesivo parcialmente e totalmente aderido ao dente. Quanto ao remanescente adesivo na base do braquete, o EDS identificou substratos de esmalte nos grupos 1 e 3 enquanto nos outros grupos verificou-se apenas remanescente adesivo sobre a base do braquete. Os resultados mostraram que os valores médio de resistência ao cisalhamento encontrados nos grupos de base modificada foram suficientes para suportar o tratamento ortodôntico. Após análise por EDS, concluiu-se que os braquetes modificados mostraram-se livres de fragmentos de esmalte, o que sugere a possível... / This study evaluated the bond strength of an experimental bracket bonded with selfadhesive resin cement, assessed the presence of enamel substrate on the bracket base after debonding and reviewed the possible methods to remove the remnant of enamel surface. Ninety bovine teeth were selected; the roots were sectioned and embedded in acrylic resin. The teeth were randomly assigned (n=15) according to the groups: G1 - metal brackets (Victory™) bonded with total etch adhesive system (Transbond™ XT), G2 - metal brackets APC (APC Plus System) without additional adhesive procedure; G3 - metal brackets APC (APC Plus system) bonded with selfetching adhesive system; G4 - metal brackets (Victory™) bonded with self-adhesive resin cement (RelyX U100); G5 - experimental brackets (modified on the Victory™ bracket basis) bonded with total etch adhesive system (Transbond™ XT); G6 - experimental brackets (modified on the Victory™ bracket basis) bonded with selfadhesive resin cement (RelyX U100) . Shear strength test of brackets was performed and after removal of the brackets, the adhesive remnant index (ARI) was observed in a stereomicroscope (30x) (Carl Zeiss, Brazil) and the bases of brackets were checked for the presence of enamel residues (Ca) by EDS . The results showed that the highest average value of shear strength was found in group 1 (14.33 MPa) and lower mean shear strength was in group 4 (2.36 MPa). Of the remaining adhesive on the bracket base EDS identified enamel substrates in groups 1 and 3, while the other groups there was only remaining adhesive on the bracket base. Therefore the experimental brackets are possible to be used in the future for orthodontics for showing lower risk of damage to the enamel.
63

Estudo dos mecanismos envolvidos na migração celular induzida pelo MTA para cavidade peritoneal de camundongos

Gomes, Alessandra Cristina [UNESP] 21 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-21Bitstream added on 2014-06-13T18:56:30Z : No. of bitstreams: 1 gomes_ac_me_araca.pdf: 617778 bytes, checksum: dc3fa0c485a53f6482fbc321ee95103f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste trabalho foi investigar os mecanismos envolvidos na migração de neutrófilos induzida pelo MTA para cavidade peritoneal de camundongos. Observouse que o MTA induziu migração de neutrófilos de maneira dose-dependente (0,5; 5; 50 e 100 mg/cavidade), alcançando o pico de migração 6 horas após a injeção do estímulo com a dose de 50 mg/cavidade. Esta migração foi parcialmente inibida pelo pré-tratamento dos animais com dexametasona (1 mg/Kg), BWA4C (50 mg/Kg) e U75302 (0,5 mg/Kg). Diferentemente, a Indometacina (5 mg/Kg) foi inefetiva neste processo. Verificou-se também que os animais estimulados com MTA (50 mg/cavidade) apresentaram uma liberação significativa de IL-1ß e MIP-2 no exsudato peritoneal. O pré-tratamento com Tioglicolato aumentou em cerca de 380% a população de macrófagos na cavidade peritoneal, potencializando a migração de neutrófilos induzida pelo MTA (p<0,05). O pré-tratamento com composto 48/80 depletou cerca de 75% a população de mastócitos, diminuindo a migração de neutrófilos (p<0,05). A injeção de MTA na bolha de ar subcutânea induziu uma migração de neutrófilos menor comparada à cavidade peritoneal. Estes resultados confirmam a participação de mastócitos e macrófagos na migração de neutrófilos induzida pelo MTA. A injeção de sobrenadante de macrófagos e mastócitos estimulados com MTA na cavidade peritoneal de camundongos causou significante migração de neutrófilos (p<0,05), que foi parcialmente inibida pelo pré-tratamento das células por dexametasona (10 æMolar), BWA4C (100 æMolar) e U75302 (10 æMolar) sugerindo a liberação por essas células de LTB4 e citocinas e/ou quimiocinas. Confirmando esses dados,... / The aim of this study was to investigate the mechanism involved in the neutrophil migration induced by MTA into peritoneal cavity in mice. It was observed that MTA induced a dose dependent neutrophil migration (0.5, 5, 50 and 100 mg/cavity), achieving the peak 6 hours after the stimulation with 50 mg/cavity. Neutrophil migration was inhibited by the pre-treatment with dexamethasone (1 mg/Kg), BWA4C (50 mg/Kg) and U75302 (0,5 mg/Kg). Differently indometacin (5 mg/Kg) was ineffective in this process. It was seen that the animals stimulated with MTA (50 mg/cavity) showed a significative amount of IL-1ß and MIP-2 released to the peritoneal exudate. The pretreatment with Thioglycolate 3% increased 380% the macropahge population into the peritoneal cavity, increasing the MTA-induced neutrophil migration (p<0.05). The pretreatment with 48/80 compound decreased 75% the mast cell population in the peritoneal cavity and decreased the MTAinduced neutrophil migration (p<0.05). The injection of MTA in the air-pouch cavity induced a neutrophil migration, however, the recruitment was shorter than that induced into the peritoneal cavity. These data confirm the participation of the mast cell and macrophages in the MTA-induced neutrophil migration. The injection of MTA-stimulated macrophages and mast cells supernatants into the mice peritoneal cavity induced a significant neutrophil migration that was inhibited by the pretreatment with dexamethasone (10 æMolar), BWA4C (100 æMolar) and U75302 (10 æMolar) suggesting the release of LTB4 and cytokines and/or chemokines by these cells. Besides, macrophages and mast cells MTA-induced were able to express in vitro IL-1ß MIP-2 and 5-LO mRNA. In conclusion, the neutrophil migration into mice peritoneal cavity induced by MTA was dependent on mast cells and macrophages, which expressed IL-1ß, MIP-2 and LTB4.
64

Avaliação qualitativa e quantitativa da resposta tecidual frente aos cimentos: MTA Ângelus cinza e MTA fotopolimerizável experimental: análise microscópica de implantes realizados em subcutâneos de ratos

Faria, Max Douglas [UNESP] 19 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-19Bitstream added on 2014-06-13T20:56:53Z : No. of bitstreams: 1 faria_md_me_araca.pdf: 716443 bytes, checksum: 4e2e4b8520c6153202509ed3a813ac26 (MD5) / A necessidade de preservar a integridade do dente sucessor permanente, em formação, na vigência do tratamento endodôntico dos dentes decíduos, tem estimulado o estudo de vários tipos de cimentos endodônticos, dentre eles o MTA. Este trabalho teve a finalidade de avaliar quantitativamente e qualitativamente a resposta inflamatória frente ao implante de tubos de polietileno e de dentina em subcutâneo de ratos, contendo, o cimento experimental desenvolvido pela Northwestern Universiy Medical School, de Chicago USA, em parceria com a empresa de materiais odontológicos Bisco comparando-o ao MTA Ângelus cinza. Foram utilizados 36 ratos, divididos em seis grupos. No grupo 1, tubos de polietileno vazios foram introduzidos no subcutâneo dos ratos para serviriam de controle para os grupos experimentais. No grupo 2 foram implantados tubos de polietileno contendo o cimento MTA Ângelus®. No grupo 3, tubos de polietileno contendo o cimento experimental fotopolimerizavel foram implantados. No grupo 4, tubos de dentina contendo MTA Angelus® foram implantados. No grupo 5, tubos de dentina contendo o cimento experimental fotopolimerizavel foram implantados. No grupo 6 tubos de dentina vazios foram implantados. Após 30 e 60 dias os animais foram sacrificados e os tubos de polietileno juntamente com o tecido que o circundava foram removidos e processadas para analise em microscopia de luz, com inclusão em parafina, cortes seriados de 6mm e coloração por HE. Os tubos de dentina foram removidos após 30 dias e processados para analise em microscopia de luz, com inclusão em cera de carnaúba, cortes seriados de 10mm e coloração de Van Kossa. Observou-se resultados mais favoráveis com MTA Ângelus®, pois o MTA experimental demonstrou resposta inflamatória de maior intensidade. / The need of preserving the integrity of a permanent successor tooth, the development on the validity of deciduous endodontic tooth, has leading to the study of several kinds of endodontic materials, such as the MTA. This study means to evaluate quantitatively and the qualification of the inflammatory response to the polyethylene and dentine tubes implants on rat's subcutaneous, containing, the experimental cement developed by Northwestern University Medical School, in Chicago USA, in association to Bisco dental material company comparing it to MTA Ângelus® gray. It was used 36 rats, divided into six groups. In group 1, empty polyethylene tubes were implanted on rat's subcutaneous as control to the experimental groups. In group 2, it was implanted polyethylene tubes containing MTA Ângelus®. In the group 3, polyethylene tubes containing the experimental cement light cured. In the group 4, dentine tubes containing MTA Ângelus® were implanted. In the group 5, dentine tubes containing the experimental cement light cured were implanted. In the group 6, empty dentine tubes were implanted. After 30 to 60 days the animal were sacrificed and the implanted polyethylene tubes and surrounding tissue were removed and processed in laboratory to analyses on light microscopy, with embedding in paraffin, cut with 6mm thickness and stained with HE. The dentine tubes were removed at the same way 30 days after implantation and processed in laboratory to analyses on light microscopy, with embedding in carnauba wax, cut with 10mm thickness without demineralization and stained with Von Kossa. It was observed favorable results to MTA Ângelus® and experimental material showed higher levels on the inflammatory process. Besides, MTA Ângelus® was the only material to show positive area of mineralization with Von Kossa staining.
65

Efeitos citotóxicos de diferentes materiais dentários sobre células de linhagem odontoblástica

Mendonça, Adriano Augusto Melo de [UNESP] 23 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-23Bitstream added on 2014-06-13T20:12:00Z : No. of bitstreams: 1 mendonca_aam_me_arafo.pdf: 391168 bytes, checksum: 5b48b4c877101be48a53fececa7c6066 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A presente pesquisa avaliou o efeito citotóxico de diferentes materiais dentários sobre células de linhagem odontoblástica MDPC-23 em cultura. Para isto, corpos-de-prova com dimensões de 4mm de diâmetro e 2 mm de profundidade foram confeccionados com os seguintes materiais: hidróxido de cálcio (Hydro C - Grupo HCa); RelyX Luting (Grupo RL); Vitrebond (Grupo VB); e RelyX Unicem (Grupo RU). Cada espécime foi imerso em meio de cultura não suplementado com soro fetal bovino (MC-SFB) e incubado pelos períodos de 24 horas ou 7 dias. Células odontoblastóides MDPC-23 foram semeadas (3x104 células/cm2) em pratos de acrílico com 24 compartimentos e incubados por 72 horas, sendo que após este período, o meio de cultura completo (DMEM) foi substituído pelos extratos obtidos de cada material experimental. Após incubação adicional de 24 horas, a atividade da enzima desidrogenase succíninca das células foi avaliada através do teste de MTT. No grupo controle, o meio de cultura foi substituído pelo MC-SFB fresco (sem tratamento). Para os períodos de 24 horas, os grupos HCa, RL, VB e RU apresentaram valores de redução no metabolismo celular de 91,52%; 78,17%; 89,14%; e 2,64%, respectivamente, quando comparados com o grupo controle (DMEM), o qual não reduziu o metabolismo celular. Com relação ao período experimental de 7 dias, os valores de redução na atividade metabólica para os grupos HCa, RL, VB e RU foram de 91,13%, 79,04%, 87,27% e 10,51%, respectivamente. Segundo a análise estatística de Kruskall-Wallis complementada pelo teste de Mann-Whitney não houve diferença entre os grupos HCa e VB, os quais foram os materiais mais citotóxicos em ambos os períodos avaliados. RU foi o cimento menos tóxico, sendo que não houve diferença estatisticamente significante com o grupo controle no período de 24 horas... / The present in vitro study evaluated the cytotoxic effects of different dental materials on the odontoblast-like cells MDPC-23. For this purpose, round samples (2-mm thick and 4-mm in diameter) were prepared with the following experimental materials: calcium hydroxide (Hydro C - Group HCa); RelyXTM Luting Cement (Group RL); Vitrebond (Group VB); and RelyXTM Unicem (Group RU). The samples were placed in fresh culture medium with no fetal bovine serum (DMEM-FBS) and incubated for 24 hours or 7 days at 37°C with 5% CO2, and 95% air. The odontoblast cells were plated (3x104 cells/cm2) in wells of five 24-wells dishes and incubated for 72 hours. After this period, the complete culture medium (DMEM) was replaced by the extracts obtained from every sample. The cells in contact with the extracts were incubated for additional 24 hours. The MTT Assay was carried out to evaluate the cell metabolism. In control group (DMEM) the nontreated fresh culture medium (DMEM-FBS) was applied on the cultured cells. At 24 hours period, the experimental materials HCa, RL, VB and RU decreased the mitochondrial respiration by: 91,52%; 78,17%; 89,14%; and 2,64%, respectively. At 7 days, the reduction of the cell metabolism for groups HCa, RL, VB and RU was: 91,13%; 79,04%; 87,27%; and 10,51%, respectively. The statistical analysis of Kruskal-Wallis complemented by the Mann-Whitney test demonstrated there was no statistical difference between the groups HCa and VB which presented the highest cytotoxic effects on the MDPC-23 cells. On the other hand, no difference statistically significant was observed between RU and DMEM, at 24 hours period. The ranking of cytotoxicity observed at 24 hours and 7 days was: HCa=VB>RL>RU=DMEM and HCa=VB>RL>RU>DMEM, respectively. Based upon the scientific data presented in this in vitro study, it was concluded... (Complete abstract, click electronic address below).
66

Avaliação in vitro da resistência de união do cerômero ao sistema de cimentação adesiva, através do teste de micro-tração. Efeito de diferentes tratamentos de superfície

Faria, Ricardo Pinheiro de [UNESP] 26 November 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-11-26Bitstream added on 2014-06-13T20:12:02Z : No. of bitstreams: 1 faria_rp_me_arafo.pdf: 2571722 bytes, checksum: 03eaaed6baf6d35de160ebd73d353c6a (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A proposta deste estudo foi avaliar in vitro a resistência de união do Cerômero Artglass (Heraeus/Kulzer) ao cimento resiniso RelyX (3M), através do teste de Micro-Tração. Os seguintes tratamentos de superfície foram investigados: microjateamento com óxido de alumínio (AO), Artglass Liquid (AL), Silano (S), ácido fluorídrico (HF) e ácido fosfórico (AF). Cinco espécimes cada qual consistindo de um par de cilindro (10x10 mm) foram confeccionados. As superfícies de união foram regularizadas através de desgaste com lixas abrasivas de granulação sequencial sob refrigeração. Os espécimes foram nomeados ao acaso e submetidos aos seguintes tratamentos antes da cimentação: grupo 1 (AO/AGL), grupo 2(AO/AF), grupo 3 (AO/AF/S), grupo 4 (AO/HF) e grupo 5 (AO/HF/S). Os espécimes aos pares foram cimentados com um sistema adesivo dual e cimento resinoso dual, de acordo com as recomendações do fabricante. Espécimes foram fotopolimerizados, armazenados por 48 horas a 37ºC e, posteriormente, termociclados. Com auxílio de um disco de diamente perpendicular a superfície de união, palitos com 1 mm2 de área de seção foram obtidos. Os valores de resistência de união (MPa) foram obtidos com auxílio de uma máquina de teste universal (MTS800). Resultados foram: grupo 1(29,39+-5,13), grupo 2 (27,49 +- 5,32), grupo 3(29,49 +- 4,94), grupo 4(24,41 +- 2,67), e grupo 5 (22,19 +- 2,33). ANOVA e o Teste de Tukey foram aplicados com p<0,05. Não houve diferenças estatisticamente significante entre os grupo 1,2 e 3; 4 e 5; e 2 e 4. As forças de união foram significantemente maiores nos grupos 1 e 3 do que nos grupos 4 e 5; e no grupo 2 do que o grupo 5. Conclusões: Microjateamento com óxido de alumínio e Artglass Liquid foi um pré-tratamento de superfície efetivo; a sinalização pode melhorar a força de união promovida pelo microjateamento e condicionamento... . / The purpose of this study was to investigate the effect of surface treatments on microtensile interfacial bond strength of a composite Artglass (Kulzer) to resin cement RelyX (3M). Methods of surfaces roughening or preparation included microetching with aluminum oxide (AO), Artglass Liquid (AGL), Silane (S), hydrofluoric acid (HF), and fosforic acid (AF). Five specimens, each consisting of a pair of cylinders (10x10 mm) were fabricated. The bonding surfaces were finished with 600-grit silicon carbide paper. Specimen pairs were randomly assigned to one of five surface treatment groups: group 1 (AO/AGL), group 2 (AO/AF), group 3 (AO/AF/S), group 4 (AO/HF), and group 5 (AO/HF/S). Specimen pairs were cemented with a dual resin bonding and a dual cure resin cement, in accordance with the manufacturer's instructions. Specimens were light-cured, then thermocycled 500 times at between 5º C and 55º C. Using a diamond disk perpendicular to the bonding interface, sticks with 1.0 mm2 cross-sectional area were obtained. Microtensile bond strengths were determined using a MTS 800 Materials Testing Machine at a crosshead speed of 0.5 mm/min. Results: Means (n=20) and standard deviations of bond strengths (MPa) were: group 1 (29.39 +- 5.13), group 2(27.49 +- 5.32), group 3(29.49 +- 4.94), group 4 (24.41 +- 2.67), and group 5 (22.19 +- 2.33). Data were analyzed with ANOVA and Tukey Test at p<0.05. There were no significant statistical differences among the groups 1,2, and group 3; groups 4 and 5; and groups 2 and 4. Microtensile bond strengths were significantly higher in groups 1 and 3 than in groups 4 and 5; and in group 2 than in group 5. Conclusions: AO and AGL was an effective surface pretreatment; silanation may improve the bond provided by AO and etching with AF; and etching with HF is not recommended, as it decreases bond strength.
67

Avaliação da infiltração bacteriana corono-apical de canais radiculares obturados com diferentes tipos de cimentos endodônticos

Pinheiro, Cláudia Ramos [UNESP] 24 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-03-24Bitstream added on 2014-06-13T20:31:49Z : No. of bitstreams: 1 pinheiro_cr_me_arafo.pdf: 1052559 bytes, checksum: 2a41a237f5d01f6a98076552b4ca2ebd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Avaliamos a infiltração coroa-ápice da bactéria Enterococcus faecalis em incisivos centrais bovinos instrumentados e obturados com os cimentos endodônticos AH Plus, Endofill, Epiphany, Acroseal e o cimento experimental à base do Polímero da mamona (Polifil). Foi confeccionado um dispositivo a ser adaptado na porção inferior de tubos de centrífuga, Eppendorf. As raízes, previamente obturadas, foram inseridas nesse dispositivo até que 5mm se projetasse para fora do tubo plástico. A junção entre o tubo e a raiz foi selada com araldite, assim como a porção da raiz, externa ao recipiente, excluindo-se 1 mm ao redor do forame apical. O dispositivo Eppendorf e raiz obturada foram fixados em frasco tipo penicilina, contendo caldo .Brain heart infusion.. Com auxílio de uma pipeta, 1mL da bactéria foi transferido ao caldo B.H.I. e 400 µL de uma cultura recente foram transferidos para a porção superior do tubo. Durante 64 dias, a infiltração bacteriana era detectada através da turvação do caldo. Os resultados foram submetidos à análise estatística. Foi utilizado o método não-paramétrico de Kaplan-Meier e o teste de Kruskal-Wallis, complementado por comparações múltiplas pelo teste de Dunn. Adotou-se o nível de significância de 5%. Os cimentos AH Plus e Endofill apresentaram resistência à infiltração bacteriana significativamente menor do que o Polifil, mas estatisticamente equivalentes entre si. Os cimentos Epiphany e Acroseal deram resultados intermediários e equivalentes, mas sem diferença estatisticamente significante em relação aos outros cimentos. / This study compared some of the endodontic sealers sealing ability (AH Plus, Epiphany, Acroseal, Endofill and Polifil (a castor oil-based experimental sealer) using the active lateral condensation technique, through a bacterial test, during 64 days. One hundred bovine incisors were selected and divided into five experimental groups and two control groups (negative and positive ones). The teeth were cleaned and shaped by the step-back technique, then, they were filled with the endodontic sealers and stored in (100%) wet environment. The roots were impermeabilized with araldite glue, adapted into an eppendorf microtube and sterilized by ethylen oxide gas. The root/ eppendorf microtube was added to penicillin flasks containing 6mL of BHI broth kept at 37º C for 4 days to confirm sterilization. After this period, 400µL of Enterococcus faecalis ATCC 29212 were inserted at the upper portion of the eppendorf microtube. Daily leakage was evaluated through the broth turbidy. The results were submitted to the statistical analysis (Kaplan-Meier method as well as Kruskal-Wallis´ and Dunn´s tests). AH Plus and Endofill sealers were statistically equivalent concerning the sealing property, showing less resistance to the bacterial leakage than Polifil, while Acroseal and Epiphany had similar and intermediate behavior, but without numerical significance when compared to the other sealers.
68

Resistência de união á dentina do canal radicular de cimentos endodônticos, em função da medicação intracanal com hidróxido de cálcio

Guiotti, Flávia Angelica [UNESP] 21 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-21Bitstream added on 2014-06-13T18:20:51Z : No. of bitstreams: 1 guiotti_fa_me_arafo.pdf: 801094 bytes, checksum: d5fa817beeaa6d42f28de7ef999ddc90 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo foi dividido em dois capítulos, tendo como objetivo comparar, através do teste de push-out, a resistência de união do cimento MTA Fillapex (Angelus, Londrina, PR, BR), Sealapex (SybronEndo, Orange, CA, USA) e AH Plus (Dentsply De Trey Gmbh , Konstanz, GE) às paredes do canal radicular de dentes humanos extraídos, após o uso prévio de três tipos de medicação intracanal contendo hidróxido de cálcio: Calen (SS White, São Paulo, SP, BR), Pasta HPG (hidróxido de cálcio, paramonoclorofenol canforado e glicerina) e Ca(OH)2 + água (hidróxido de cálcio + água). Foram utilizados 60 dentes unirradiculares, que tiveram suas coroas seccionadas na junção amelocementária. As raízes foram incluídas em resina epóxi e cortadas transversalmente em fatias de 2 mm dos terços cervical, médio e apical das raízes. Em seguida, utilizando uma fresa tronco-cônica acoplada em micromotor, devidamente adaptado em um delineador, os canais foram preparados, padronizados e submetidos à irrigação com o EDTA a 17%. No primeiro estudo (Capítulo 1), os espécimes foram divididos em seis grupos: G1- MTA Fillapex; G2-Sealapex; G3-AH Plus, após o uso prévio das respectivas medicações com hidróxido de cálcio, por 21 dias. Após este período, os espécimes foram irrigados com NaOCl a 2,5% e EDTA a 17%, sendo então preenchidos com um dos cimentos em estudo, mantendo os corpos de prova por 7 dias, a 37˚C e 95% de umidade. Nos grupos 4, 5 e 6 foram utilizados os mesmos cimentos, sem uso da medicação intracanal, respectivamente. No segundo estudo (Capílulo 2), os espécimes foram distribuídos por grupos e os canais radiculares obturados com: G1- MTA Fillapex e G2-Sealapex. Cada grupo foi subdividido em três sub-grupos, em função da associação da medicação intracanal com hidróxido de cálcio previamente empregada: A - sem medicação; B - Ca(OH)2 + água destilada... / The aim of this study, divided in two chapters, was to evaluate and to compare the push-out bond strength of three root canal sealers to the root canal walls of human extracted teeth: MTA Fillapex (Angelus, Londrina, PR, BR), Sealapex (SybronEndo, Orange, CA, USA) and AH Plus (Dentsply De Trey Gmbh, Konstanz, GE), after the previous use with three calcium hydroxide compositions with intracanal medication: Calen (SS White, São Paulo, SP, BR), HPG paste (Calcium hydroxide, Paramonoclorofenol canforado and Glycerin) and Calcium hydroxide with water paste. Sixty unirradicular teeth were sectioned transversally below the cement-enamel junction. The roots were included in epoxy resin and cut transversally, obtained 2 mm-thick cross-section slices of cervical, middle and apical radicular thirds. In sequence, using a conic drill adjusted in a low electric piece adapted in a pararelometer , the canals were prepared, standardized and submitted to irrigation with EDTA to 17%. In the first study (Chapter 1), the specimens were divided into six groups: G1-MTA Fillapex; G2-Sealapex; G3-OH Plus, after the prior use of calcium hydroxide intracanal medication, by 21 days. After, were irrigated with the 2.5% NaOCl and then filled with one of the materials, stored at 37˚C, for 7 days and 95% of relative humidity. In groups 4, 5 and 6 were used the same cement, without intracanal medication, respectively. In the second study (Chapter 2), the specimens weredivided and the canals obturated with: G1- Fillapex MTA and G2-Sealapex. Each group was subdivided into three sub-groups, depending of the calcium hydroxide intracanal medication composition, previously used: A-without medication; B- distilled water and C- Glycerin/camphorate paramonochlorophenol . After 7 days, the specimens were submitted to the push-out test in mechanical testing machine. The data were analyzed with ANOVA and Tukey test (α = 5%)... (Complete abstract click electronic access below)
69

Avaliação dos sistemas MTwo Retratamento e ProTaper Universal Retratamento na remoção de guta-percha e novos cimentos endodônticos dos canais radiculares

Moreira, Camila Said [UNESP] 12 December 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-12-12Bitstream added on 2014-06-13T20:12:44Z : No. of bitstreams: 1 moreira_cs_me_sjc.pdf: 548037 bytes, checksum: 08067892942db60d34c48b98e0615b5c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar, in vitro, a eficácia dos sistemas MTwo Retratamento e ProTaper Universal Retratamento na remoção de diferentes cimentos endodônticos associados à guta-perchas das paredes dos canais radiculares. Sessenta dentes unirradiculares humanos extraídos foram instrumentados com limas rotatórias e divididos de forma aleatória em 3 grupos (n=20). Os canais radiculares foram obturados com guta-percha associada aos cimentos AHPlus Jet®, MTA Fillapex® e RoekoSeal Automix®. Os espécimes foram radiografados após a obturação para conferência do preenchimento radicular. Após 30 dias mantidos em estufa a 37ºC e umidade relativa em 100%, os espécimes foram desobturados seguindo duas diferentes técnicas de retratamento: com limas rotatórias MTwo Retratamento® e com limas rotatórias ProTaper Universal Retratamento®. Através de películas tomográficas feitas antes e após a desobturação, pelo método do feixe cônico, os espécimes foram avaliados quanto à área total de material obturador e quanto à quantidade de material obturador remanescente nos canais radiculares após a desobturação. Durante o retratamento, o tempo de desobturação foi cronometrado. Os dados relativos à quantidade de material remanescente e tempo de desobturação foram submetidos à análise estatística utilizando ANOVA e teste de Tukey com nível de significância de 5%. Nenhum sistema rotatório foi capaz de remover todo o material obturador dos canais radiculares. Não houve diferenças significantes entre os sistemas rotatórios, porém ambos se mostraram rápidos e eficientes. O cimento AHPlus Jet foi o mais difícil de ser removido e foi o cimento que deixou maior quantidade de material obturador remanescente nas paredes radiculares / The purpose of this study was to evaluate, in vitro, the efficacy of MTwo Retreatment and ProTaper Universal Retreatment Systems in the removal of filling material from root canals. Sixty single-rooted human teeth were prepared by using nickel-titanium rotary files and randomly allocated into 3 groups (n=20). The root canals were filled with gutta-percha and AHPlus Jet®, MTA Fillapex® and RoekoSeal Automix®. After 30-day storage at 37oC and 100% humidity, the root fillings were removed using MTwo Retreatment or ProTaper Universal Retreatment files. The specimens were analyzed through tomographic images after root canal filling and after retreatment. The images were digitalized and analyzed by software Image Tool for Windows (version 3.0) for evaluation of remaining filling material. During the retreatment, time required for endodontic filling removal was analyzed. Data were submitted to statistical analysis by ANOVA and Tukey tests at the significance of 5%. None of the rotarysystems was able to remove the entire root canal filling material. There were no significant differences between the rotary systems, but both proved to be fast and efficient. The AHPlus Jet sealer was the most difficult to be removed and it was the sealer that left more remaining filling material on the walls root
70

Efeito de tratamento de superfície do titânio comercialmente puro na resistência de união com cimentos ionomérico e resinosos

Abi Rached, Filipe de Oliveira [UNESP] 31 March 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-03-31Bitstream added on 2014-06-13T20:18:32Z : No. of bitstreams: 1 abirached_fo_me_arafo.pdf: 762282 bytes, checksum: bf4b7b544331c76ec042fed619402110 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O titânio, em virtude de suas atrativas propriedades, foi introduzido na área de reabilitação oral podendo ser indicado para a confecção de restaurações metalocerâmicas dento- ou implanto-suportadas. No entanto, apresenta dificuldade de união com materiais resinosos, o que poderia comprometer a longevidade dessas restaurações, considerando a importância da qualidade de união na interface metal/cimento. Para contornar este problema, pode-se lançar mão de tratamentos de superfície do titânio, empregados isoladamente ou em associação. Este estudo avaliou a eficácia de diferentes tratamentos de superfície na resistência ao cisalhamento (RC) da união do cimento ionomérico modificado por resina RelyX Luting 2 e dos cimentos resinosos RelyX ARC e RelyX U100 ao titânio comercialmente puro (Ti cp). Duzentos e quarenta discos (9 x 3 mm) foram fundidos em Ti cp, incluídos em tubos de PVC e regularizados com lixas de carbeto de silício (150, 400 e 600) em politriz. Os espécimes foram divididos aleatoriamente em oito grupos (n=30), os quais receberam um dos seguintes tratamentos de superfície: (1) Al2O3 50 μm; (2) Al2O3 120 μm; (3) Al2O3 250 μm; (4) Al2O3 50 μm + silano; (5) Al2O3 120 μm + silano; (6) Al2O3 250 μm + silano; (7) Cojet Sand (30 μm) + silano; (8) Al2O3 120 μm + Rocatec (110 μm) + silano. Os cimentos (1) RelyX Luting 2; (2) RelyX ARC; (3) RelyX U100 foram aplicados às superfícies tratadas do Ti cp (n=10). Os espécimes foram termociclados (5.000 ciclos, 5 e 55 °C, 30 segundos de imersão) e, então, submetidos ao ensaio de cisalhamento (0,5 mm/min). O modo de fratura foi avaliado em estereomicroscópio (x20). Os dados foram analisados por ANOVA 2 fatores e teste de Tukey (α=0,05). Os cimentos RelyX Luting 2 e RelyX U100 apresentaram comportamento semelhante com relação ao tratamento de superfície... / Titanium was introduced in the field of oral rehabilitation because of its attractive properties, as it can be indicated for fabricating tooth- or implant-supported metal ceramic restorations. However, difficulties have been shown to exist as regards the bond between resin-based materials and titanium, which could compromise the longevity of these restorations, considering the importance of the bond quality at the metal/cement interface. To overcome this problem, titanium surface treatments can be applied alone or they can be combined with each other. This study evaluated the efficacy of different surface treatments on the shear bond strength (SBS) of RelyX Luting 2 resin-modified glass ionomer cement, RelyX ARC and RelyX U100 resin cements to commercially pure titanium (CP Ti). Two hundred and forty discs (9 x 3 mm) were cast from CP Ti, embedded in PVC tubes and smoothed with silicon carbide papers (150, 400 and 600) using a polisher. Specimens were randomly divided into 8 groups (n=30), which received one of the following surface treatments: (1) 50 μm Al2O3; (2) 120 μm Al2O3; (3) 250 μm Al2O3; (4) 50 μm Al2O3 + silane; (5) 120 μm Al2O3 + silane; (6) 250 μm Al2O3 + silane; (7) Cojet Sand (30 μm) + silane; (8) 120 μm Al2O3 + Rocatec (110 μm) + silane. The luting cements (1) RelyX Luting 2; (2) RelyX ARC; (3) RelyX U100 were applied to the treated CP Ti surfaces (n=10). Specimens were thermal cycled (5,000 cycles, 5 and 55 °C, 30-second dwell time), and afterwards submitted to SBS testing (0.5 mm/min). Failure mode was evaluated under a stereomicroscope (x20). Data were analyzed using 2-way ANOVA and Tukey’s test (α=0.05). The RelyX Luting 2 and RelyX U100 luting cements exhibited similar behavior regards to the surface treatment. For both, only the group abraded with 50 μm Al2O3 particles promoted lower SBS than the other groups (P>.05)... (Complete abstract click electronic access below)

Page generated in 0.0805 seconds