• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 114
  • Tagged with
  • 114
  • 114
  • 52
  • 46
  • 44
  • 35
  • 34
  • 19
  • 16
  • 15
  • 14
  • 14
  • 14
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Influência da técnica de cimentação adesiva intra-radicular na resistência ao cisalhamento de pinos de fibra de vidro

Machado, Renata Gondo January 2005 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-graduação em Odontologia / Made available in DSpace on 2013-07-15T22:46:22Z (GMT). No. of bitstreams: 1 221958.pdf: 34255385 bytes, checksum: b8d181dfa0d88e5a44a3c5b53eee751a (MD5) / O estudo avaliou a influência da técnica de cimentação na resistência adesiva de pinos de fibra. Sessenta dentes foram selecionados, preparados com para cimentação de pinos e divididos em cinco grupos, de acordo com o sistema adesivo. Metade dos espécimes foi cimentada com cimento dual e a outra metade com cimento autopolimerizável. Todos os espécimes foram seccionados e submetidos ao teste de cisalhamento por extrusão. Os maiores valores de resistência foram obtidos com o cimento de polimerização dual associado aos adesivos autopolimerizável autocondicionante e adesivo dual de condicionamento ácido total. A seleção adequada do cimento resinoso e do sistema adesivo é imprescindível para evitar reações adversas e garantir efetividade adesiva. Os resultados são expressivamente inferiores aos relatados em estudos em dentina coronária.
82

Desenvolvimento de um dinamômetro digital para padronização da força de cimentação e sua influência na espessura de película de restaurações cerâmicas

Barbosa, Marcelo Taveira January 2011 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-07-16T04:17:57Z (GMT). No. of bitstreams: 1 314247.pdf: 6941180 bytes, checksum: b9d1362388c6a5ff1a943eaea3d68703 (MD5) / O objetivo deste estudo foi propor uma padronização da força na técnica de cimentação. Inicialmente, desenvolveu-se um dinamômetro digital, aplicável clinicamente, para padronizar a força de cimentação. Em seguida, realizou-se uma avaliação comparativa da adaptação interna de coroas cerâmicas cimentadas com força manual e com o dinamômetro. Dez molares humanos receberam preparo para coroa total. Para cada molar confeccionou-se uma coroa cerâmica pelo sistema injetável de IPS Empress 2 e cobertura com cerâmica IPS e.max Ceram. Para os testes, um manequim com os dentes naturais foi acoplado a uma cabeça simulando lábios e bochechas. Para a cimentação, cada coroa foi preenchida com o silicone de adição específico recém-manipulado e imediatamente adaptada a seu respectivo dente. No grupo mecânico, a ponteira do dinamômetro foi inserida na cavidade oral, e a ponta com o silicone de proteção foi posicionada sobre a coroa cerâmica. A mordida foi estabilizada por 3min com uma força de ~20,00N. Para a cimentação manual, selecionaram-se três operadores com pós-graduações. Cada operador executou a força de cimentação, com a carga que julgou ser adequada, por 3min. Após, realizaram-se os cortes transversais das réplicas nos sentidos vestibulolingual e mésio-distal. Para cada um dos 4 segmentos foram realizadas três mensurações em cada local (cervical, axial e oclusal). As médias finais das espessuras de películas foram de 86,48µm para o grupo mecânico e de 103,58µm, 103,05µm e104,49µm para os grupos de cimentação manual. Embora as médias não tenham sido estatisticamente diferentes, a cimentação com o auxílio do dinamômetro padronizou a força de cimentação, evitando forças exageradamente baixas ou excessivas, e diminuiu a dependência da auxiliar, liberando as mãos do profissional para a remoção de excessos, conferências das margens e estabilização da restauração indireta
83

Avaliação do grau de microinfiltração marginal de restaurações classe II, tipo "slot", na junção amelocementária, em molares decíduos, restaurados com cimento de ionômero de vidro fotoativado e resina composta :: estudo in vitro /

Coelho, Leda Maria Sabarrós January 1999 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. / Made available in DSpace on 2012-10-18T16:52:54Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-09T02:12:16Z : No. of bitstreams: 1 141870.pdf: 3913408 bytes, checksum: df1af5f539a2236be15b6841d40863b0 (MD5)
84

Avaliação da capacidade seladora apical de um adesivo dentinário, acrescido ou não de hidróxido de cálcio, comparada à de um cimento endodôntico à base de hidróxido de cálcio, na obturação de canais radiculares

Camargo, Carlos Henrique Ribeiro [UNESP] 12 February 1998 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:30Z (GMT). No. of bitstreams: 0 Previous issue date: 1998-02-12. Added 1 bitstream(s) on 2015-12-10T14:28:36Z : No. of bitstreams: 1 000087422.pdf: 3656117 bytes, checksum: e95eff792be63b40cced16c8ec5686bf (MD5) / O selamento em obturações endodônticas, utilizando adesivo dentinário acrescido ou não de hidróxido de cálcio, foi comparado ao obtido com um cimento endodôntico comercial, à base de hidróxido de cálcio. Sessenta dentes, divididos em grupos de vinte, tiveram seus canais preparados e obturados pela técnica da condensação lateral de guta-percha, utilizando-se como cimento obturador um adesivo dentinário acrescido ou não de hidróxido de cálcio e um cimento endodôntíco, à base de hidróxido de cálcio (grupo controle). As superfícies externas das raízes foram impermeabilizadas, exceto o forame apical. Os espécimes foram conservados em umidade relativa de 100%, a 37°C, até o momento de sua imersão em corante azul de metileno a 2%, sob vácuo por trinta minutos e à pressão atmosférica por mais 168 h, a 37°C. Após esse período, os espécimes foram lavados em água corrente por 24 h e os agentes impermeabilizantes foram removidos. Cada raiz foi seccionada ao meio, no sentido vestíbulo lingual, permitindo visualizar a interface material obturador/canal radicular. As médias de infiltração foram 2,88mm para o grupo do adesivo associado ao hidróxido de cálcio; 1,87mm para o grupo do adesivo e 0,56mm para o grupo controle. A análise estatística mostrou não haver diferença entre os resultados dos dois primeiros grupos. As infiltrações observadas no grupo controle foram as menores e estatisticamente diferentes das dos grupos experimentais / The sealing afforded by endodontic obturations using a dentin bonding agent with and without calcium hydroxide was compared to the sealing of a calcium hydroxide - based sealer (Sealer 26). The root canals of sixty extracted human teeth were prepared biomecanichally and filled by the lateral condensation technique with gutta-percha points and the sealer (Sealer 26) as the control group, or a dentin bonding agent with calcium hidroxide or dentin bonding agent without calcium hydroxide. The roots were placed into a 2% metlylene blue dye solution under vacuum for thirty minutes. After this period they were kept for 168h at 37ºC. The roots were sectioned longitudinally and the depth of dye penetration mensured linearly, in a steriomicroscope. The mean values were: 2,88mm for the the dentin bonding agent with calcium hydroxide group; 1,87mm for the dentin bonding agent group and 0.56 mm for the control group. The results showed that the control group leakage significanty less (p 0,05) than the other two groups, which exhibited no statistical difference between both of them
85

Avaliação por microdureza Vickers da profundidade de polimerização de cimentos resinosos na cimentação de pinos de fibra de vidro empregando diferentes fontes de luz

Conti, Elaine Cristina Guerbach [UNESP] January 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2006Bitstream added on 2014-06-13T20:41:44Z : No. of bitstreams: 1 conti_ecg_dr_arafo.pdf: 812838 bytes, checksum: c0f89cff921f9b0a2343ffde10308ae3 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse estudo foi avaliar a microdureza Vickers de um cimento resinoso químico (C&B Cement - Bisco) e um de ativação dual (RelyX ARC - 3M ESPE), fotopolimerizado por diferentes fontes de luz, em função de diferentes profundidades do canal radicular, na cimentação de pinos de fibra de vidro. Os aparelhos fotopolimerizadores empregados foram: Optilux 360 (Demetron) - luz halógena; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. Nenhuma diferença estatisticamente significante foi observada nos valores de microdureza Vickers, dos terços cervical, médio e apical do canal radicular, para o cimento resinoso químico (G1), e os terços cervicais do cimento resinoso dual, para todos os aparelhos fotopolimerizadores (G2, G3 e G4) (p>0.05). Porém, o aparelho de luz halógena (G2) e o LED UltraLume 5 (G4) apresentaram comportamentos semelhantes, proporcionando uma diminuição gradativa nos valores médios de microdureza do cimento resinoso dual, do terço cervical para o apical (p<0.001). Os menores valores de microdureza foram encontrados nos terços apical do sistema RelyX ARC fotopolimerizado com luz halógena ou com LED UltraLume 5. / This study evaluated the Vickers microhardness of a chemically cured resin cement (C&B Cement - Bisco) and a dual cure cement (RelyX ARC - 3M ESPE), light cured by different light sources, according to the different root canal depths, for luting of glass fiber posts. The light curing units employed were Optilux 360 (Demetron) - halogen lamp; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. No statistically significant difference was observed in Vickers microhardness values at the cervical, middle and apical root thirds for the chemically cured resin cement (G1), and at the cervical third for the dual resin cement, for all light curing units (G2, G3 and G4) (p>0.05). However, the halogen lamp unit (G2) and LED UltraLume 5 (G4) presented similar performance, providing gradual reduction in mean microhardness values for the dual resin cement from the cervical to the apical third (p<0.001). The lowest microhardness values were found at the apical third for the system RelyX ARC light cured with halogen lamp or LED UltraLume 5.
86

Avaliação in vitro da infiltração marginal em inlays de resinas compostas em função de tipos de fontes de luz e agentes de cimentação

Calabrez Filho, Saturnino [UNESP] 14 September 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-09-14Bitstream added on 2014-06-13T19:41:15Z : No. of bitstreams: 1 calabrezfilho_s_dr_arafo.pdf: 1543575 bytes, checksum: 53cda3ebc681f14a9c6a7769226d8a18 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar a infiltração marginal da resina Flow Filtek e do cimento resinoso dual RelyX na fixação de inlays de cerômeros fotoativados com LEDs e Luz Halógena. Foram selecionados 32 dentes íntegros recém-extraídos armazenados em solução de soro fisiológico no freezer, divididos em quatro grupos: Grupo I - aparelho Elipar FreeLight e resina Flow Filtek ; Grupo II - aparelho Ultralux® e Resina Flow Filtek ; Grupo III - aparelho Elipar FreeLight e cimento resinoso RelyX e Grupo IV - aparelho Ultralux® e cimento resinoso RelyX . Foram feitos 64 preparos cavitários com término em esmalte e cemento a 1 mm acima e abaixo da junção amelo-cementária respectivamente. As inlays foram jateadas internamente com óxido de alumínio de 100 æm com 40 Bar de pressão e, posteriormente foi feito o condicionamento das superfícies das inlays com ácido fosfórico a 37% durante 60 segundos, as quais foram lavadas e silanizadas. Após o condicionamento das inlays, foi feito o preparo da superfície dental com ácido fosfórico a 37% durante 15 segundos, as quais foram lavadas, secas com papel absorvente, tendo sido aplicado o adesivo dentinário Single Bond (3m/Espe), e fixadas com seus respectivos cimentos. Posteriormente à fixação, foram fotoativadas pelos aparelhos em íntimo contato com sua superfície por 60 segundos, termociclados com 1.000 ciclos variando-se a temperatura de 5ºC a 55ºC, em seguida imersas em solução de fucsina básica a 5% durante 24 horas, lavadas e seccionadas no centro da restauração para que fosse feita a medida da infiltração em um Software Image Tool calibrado em milímetros, pelo qual foram selecionados os resultados que apresentavam maiores infiltrações em medidas lineares para aplicação dos testes estatísticos.... / The objective of this work was to evaluate the microleakage of the Flow Filtek resin and dual luting RelyX in the fixation of composite resin inlays cured with LEDs and Halogenic Light units. 32 recently extracted complete teeth were selected stored in solution of physiologic serum in freezer, divided in four groups: I Group I- Elipar FreeLight unit and Flow Filtek resin; Group II- Ultralux® unit Flow Filtek resin; Group III- Elipar FreeLight unit and RelyX luting and Group IV- Ultralux® unit RelyX luting. They were made 64 cavitary preparations with end in enamel and dentine with 1 mm above and below enamel-dentin junction respectively, the inlays were sandblasted internally with 100æm/40 pressure Bar and later made the conditioning of the surfaces of the inlays with phosphoric acid to 37% goes 60 seconds, washed and silanizadas. After the conditioning of the inlays they were made the preparation of the dental surface with phosphoric acid to 37% for 15 seconds, washed, dried with absorbent and applied paper the dentinal sticker Single Bond (3m/Espe) and fastened with their respective luting. Later the fixation, these were cured for the units in intimate contact with its surface for 60 seconds. The samples were then thermocycled with 1000 cycles varying the temperature of 5ºC and 55ºC, soon afterwards immersed in solution of basic fucsina to 5% for 24 hours, washed and split up in the center of the restoration so that it was made the measure of the microleakage in a Software Image Tool gaged in millimeters, where they were selected the results that presented larger leakage in lineal measures for application of the statistical tests... (Complete abstract, click electronic address below).
87

Comparação in vitro da adesão de diferentes cimentos endodônticos à dentina radicular e aos componentes sólidos da obturação

Barbizam, João Vicente Baroni [UNESP] 26 July 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-07-26Bitstream added on 2014-06-13T18:42:18Z : No. of bitstreams: 1 barbizam_jvb_dr_arafo.pdf: 425567 bytes, checksum: 60f631b7710a86a21e5f8d7f64f0ba90 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse estudo é avaliar in vitro, por meio dos testes de push-out e tração, a adesão de diferentes cimentos endodônticos à dentina e aos componentes sólidos da obturação, guta-percha e resilon. Sessenta dentes humanos uniradiculares tiveram suas coroas removidas e foram divididos em três gupos de vinte dentes. Cada grupo foi instrumentado pela técnica rotatória até uma lima tipo Profile 40.04 e alargados com uma broca de preparo de pino com 1,5 mm de diâmetro, sob irrigação com hipoclorito de sódio 2,5% (NaOCl) seguido de irrigação final com EDTA 17%; gel de clorexidina 2%(CHX) alternado com soro fisiológico e seguido por EDTA 17% ou apenas com soro fisiológico, como controle. A seguir, foram obturados com os cimentos AH 26, Endo Fill, Endo Rez e Epiphany. Após 48 horas de incubação a 37 graus Celsius e 100% de umidade, os dentes foram cortados tranversalmente em discos de 2 mm de espessura. As amostras foram submetidas à força de compressão pelo teste de push-out. Para o teste de tração, discos de guta-percha e resilon foram criados e os cimentos AH 26, Endo Fill, Endo Rez e Epiphany foram colocados em contato com o material sólido da obturação por meio de anéis metálicos contendo os cimentos em seu interor. Após incubação as amostras foram submetidas ao teste de tração. Ambos os testes foram realizados em máquina de ensaios (1mm/min) e os resultados expressos em Mpa. O teste Anova e Newman-Keuls evidenciaram que cimento Epiphany apresentou maior adesão à dentina no teste de push-out, seguido pelos cimentos Endo Rez e AH 26 que foram semelhantes entre si e, por último o cimento Endo Fill. O uso da CHX aumentou a adesão à dentina de todos os cimentos testados. No teste de tração aos componentes sólidos, o cimento AH 26 mostrou ter uma maior adesão que os demais cimentos, que foram semelhantes entre si. / The aim of this in vitro study was to evaluate the bond strength of different root canal sealers to dentin and to the filling core material, using push-out and tensile tests. Sixty extracted single-rooted human teeth were divided into three groups and evenly instrumented with the crown-down technique up to a file #55 followed by a root canal enlargement using a 1,5 mm diameter post drill. Teeth were prepared under irrigation with 2.5% NaOCl + EDTA 17 %, 2% CHX associated to a saline solution + EDTA 17% or just saline solution, as control. All teeth were completely filled with AH 26, Endo Rez, Endo Fill and Epiphany sealers. After 48 hours of storage in 100% humidity at 37°C, all samples were sectioned transversally into 2mm thickness disks and the push-out tests were performed. For the tensile tests, gutta-percha and resilon disks were created and metallic rings with the sealers were positioned over the core material disks, in the same time/temperature conditions. Both push-out and tensile tests were performed using the universal testing machine (1 mm/min) and the maximum load at failure expressed in MPa. Two-way ANOVA and Newman-Keuls tests showed that Ephipany sealant presented the highest bond strength to dentin followed by Endo REZ and AH 26 that were similar to each other and Endo Fill with the lowest values of bonding to dentin. 2% CHX irrigation increased the bonding strength of all sealers to dentin. Tensile tests to the filling core materials showed that AH 26 presented the highest values of bonding. No statistical differences were found between the other sealers.
88

Avaliação da reação tecidual frente aos cimentos MTA Ângelus® cinza e um MTA fotopolimerizável experimental: análise microscópica em alvéolos dentários de ratos

Costa, Mariana Machado Teixeira de Moraes [UNESP] 25 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-25Bitstream added on 2014-06-13T19:03:55Z : No. of bitstreams: 1 costa_mmtm_dr_araca.pdf: 1110079 bytes, checksum: 91b6d45dfad96a82f57a7802c12b0cb7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Para contornar algumas dificuldades de manipulação do agregado de trióxido mineral (MTA) convencional, um MTA fotopolimerizável vem sendo desenvolvido. Desta forma, o objetivo do presente estudo foi avaliar a resposta tecidual frente ao uso deste material. Para isso, 57 tubos de polietileno preenchidos com o MTA experimental e o MTA cinza foram implantados em alvéolos de ratos. Como grupo controle, foram implantados tubos vazios. Os animais foram sacrificados após 30, 60 e 90 dias, sendo realizada a análise microscópica dos cortes obtidos e corados com Hematoxilina e Eosina. Foi possível concluir que o MTA fotopolimerizável apresentou uma resposta semelhante ao MTA cinza, caracterizada pela ausência de uma inflamação severa e pela deposição de tecido mineralizado em contato com o material. / The aim of this study was to evaluate the tissue reaction to a Light Cured MTA or MTA Ângelus® gray. It was used 57 animals, which were divided in three groups. In the Control Group, empty tubes were inserted into the rat’s sockets immediately after extraction. In the other groups, the tubes were filled with Light Cured MTA or MTA Ângelus®. After 30, 60 and 90 days after the implantation, the animals were sacrificed and the right hemi-maxilas were removed and processed in laboratory to analyses on light microscopy, with embedding in paraffin, cut with 6μm thickness and stained with HE. It was possible to conclude that Light Cured MTA presented a similar response when compared to MTA Ângelus®, being characterized by a mild inflammatory response and dystrophic calcifications areas. Despite of a favorable healing process obtained with this new experimental MTA, further studies should be conducted to elucidate these material properties and confirm the present results.
89

Avaliação de protocolos para colagem de bráquetes cerâmicos e remoção do adesivo remanescente com vistas á preservação da integridade de esmalte dentário

Vianna, Alexandre Protásio [UNESP] 08 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-08Bitstream added on 2014-06-13T19:07:08Z : No. of bitstreams: 1 vianna_ap_dr_arafo.pdf: 843063 bytes, checksum: 4531dd78f0e6348ef44fc614df388067 (MD5) / Introdução: Este estudo teve como objetivos: Avaliar a influência de diferentes protocolos de condicionamento do esmalte e de cura luminosa dos sistemas adesivos testados, na resistência da colagem de bráquetes de cerâmica ao cisalhamento; na ocorrência de fraturas de esmalte e na quantidade de adesivo remanescente. Além disso, o Método dos Elementos Finitos foi empregado para analisar como os esforços relativos à descolagem atuaram na superfície do esmalte. Com auxílio da Microscopia eletrônica de varredura, avaliou-se a ação de 05 métodos para remoção da camada de adesivo remanescente quanto às alterações geradas nas características superficiais originais do esmalte e quanto ao tempo de execução dos procedimentos. Material de Método: 40 bráquetes Inspire IceTM, 40 bráquetes ClarityTM e 40 bráquetes GeminiTM foram aleatoriamente colados a 120 pré-molares com faces vestibulares hígidas, seguindo diferentes protocolos de condicionamento do esmalte e de fotopolimerização. Essas colagens foram testadas em ensaio mecânico por cisalhamento e também analisadas pelo método dos elementos finitos. Além disso, 25 molares permanentes com faces vestibulares hígidas passaram pela remoção de camadas padronizadas de adesivo remanescente com 05 métodos diferentes. As superfícies iniciais e finais de cada dente foram avaliadas por meio da microscopia eletrônica de varredura. O tempo gasto na execução de cada procedimento foi também avaliado. Resultados: As colagens com o TPSEP apresentaram menores valores de resistência da colagem ao cisalhamento e não estiveram associadas a fraturas de esmalte. Houve coincidência entre o modo de descolagem dos braquetes e a distribuição dos esforços na superfície do modelo 3D. As menores alterações à superfície do esmalte foram geradas... / Introduction: The aims of this study were to evaluate the influence of different protocols for enamel acidic etching and for light-curing of the adhesive systems tested about: shear bond strength of ceramic brackets; occurrence of enamel fractures and adhesive remnant index. Finite element method was also used to identify how debonding efforts act on enamel surface. Scanning Electron Microscopy was applied to assess the changes observed on original enamel surface characteristics generated by 05 methods for residual adhesive removal. The chair time related to the 05 methods under study was also evaluated. Material and Methods: 40 Inspire Ice Brackets; 40 Clarity Brackets and 40 metal Brackets (Gemini) were randomly bonded to 120 bicuspides, using different protocols of enamel conditioning and photo-activation. 25 permanent molars were submitted to the removal of standardized adhesive layers, using 05 different methods. Initial and final surfaces were comparatively evaluated by scanning electron microscopy. The procedures chair times were also assessed. Results: Transbond Plus Self-etching Primer promoted bracket bonding with lower shear bond strengths and debonding procedures without enamel fractures. FEM analysis showed coincidence among efforts distribution simulated over the tridimensional model surfaces and the real debonding damages caused on enamel. The multi-blade carbide bur in low hand-piece speed caused lower alterations over enamel original surface. Conclusion: TPSEP seemed to be the adequate method for bracket bonding; metallic bracket bonding showed lower shear bond strength without primer light-curing but it was not true for the ceramic brackets; chair time of the procedure and the final aspect of enamel surface demonstrated... (Complete abstract click electronic access below)
90

Utilização de enxerto ósseo autógeno, biovidros e cimento de fosfato de cálcio em defeitos ósseos criados cirurgicamente em mandíbulas de macacos Cebus apella. Estudo histológico

Cancian, Daniela Cristina Joannitti [UNESP] 04 April 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-04-04Bitstream added on 2014-06-13T20:25:02Z : No. of bitstreams: 1 cancian_dcj_dr_arafo.pdf: 701669 bytes, checksum: fd8aefd8d48f51c10e40c62ed9f6db8a (MD5) / A proposição deste estudo foi avaliar histologicamente a efetividade do PerioGlass, Fillerbone e Bone Source no preenchimento de cavidades ósseas cirurgicamente criadas em mandíbulas de macacos adultos jovens Cebus apella. Foram criadas duas cavidades transfixantes de 5mm de diâmetro nos ângulos mandibulares. Os defeitos ósseos foram preenchidos aleatoriamente e os grupo divididos da seguinte forma: Grupo I - cavidades preenchidas com osso cortiço-medular autógeno de tíbia; Grupo II - cavidades preenchidas com cimento de fosfato de cálcio (Bone Source); Grupo III - cavidades preenchidas com vidro bioativo (Fillerbone); Grupo IV - cavidades preenchidas com vidro bioativo (PerioGlass). Após 180 dias os animais foram sacrificados, as peças removidas e processadas para obtenção de cortes histológicos. A análise histológica dos resultados demonstrou que a utilização de enxerto ósseo autógeno permitiu reparação total do defeito ósseo; os materiais Fillerbone e PerioGlass permitiram reparo total dos defeitos com íntimo contaato dos grânulos dos materiais com o tecido ósseo neoformado; o material Boné Source não permitiu reparação do defeito ósseo ocorrendo preenchimento do defeito por tecido conjuntivo fibroso e foi em grande parte reabsorvido. / The present study evaluated histological results of filling with autogenous bone, PerioGlass, Fillerbone and Bone Source in bone cavities surgically created in mandible of Cebus apella Monkeys. The surgical cavities were prepared through both mandibular cortices, with a diameter of 5mm, inthe mandibular angle region. The cavities were randomized filled and the groups divided according to the material employed as follow: Group I - Filled with tibial autogenous corticocancellous bone; Group II - Filled with calcium phosphate cement (Bone Source); Group III - Filled with bioactive glass (Fillerbone); Group IV - Filled with bioactive glass (PerioGlass). After 180 days the animals were sacrificed and the specimens followed routine laboratory procedures for hematoxilin/eosin staining and histological evaluation. The histological analysis showed that the autogenous bone allowed total repair of the bone defects; Fillerbone and PerioGlass allowed total repair of the defects with intimate contact of the remaining granules and newly formed bone; Bone Source did not allow bone formation with filling of the defects by connective fibrous tissue and the material was almost totally ressorbed.

Page generated in 0.1135 seconds