• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 874
  • 51
  • 51
  • 51
  • 50
  • 39
  • 8
  • 7
  • 7
  • 5
  • 4
  • 4
  • 4
  • 2
  • 1
  • Tagged with
  • 889
  • 425
  • 367
  • 327
  • 266
  • 195
  • 182
  • 176
  • 169
  • 162
  • 146
  • 137
  • 129
  • 126
  • 126
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
331

Avaliação do comportamento biológico do cimento endodôntico MTA Fillapex em tecido ósseo de ratos / Evaluation of rat bone tissue response to MTA Fillapex

Assmann, Eloísa January 2013 (has links)
Introdução: A biocompatibilidade é uma propriedade importante e necessária a um cimento endodôntico. O objetivo do presente estudo foi fazer uma análise microscópica das reações do tecido ósseo do fêmur de ratos da linhagem Wistar frente ao cimento MTA Fillapex, comparando-as ao cimento AH Plus e ao grupo controle (cavidade vazia), nos períodos de 7, 30 e 90 dias. Materiais e Métodos: Foram utilizados 18 animais, divididos em 3 grupos, de acordo com o período experimental (n=6). Três cavidades foram preparadas no fêmur da pata traseira direita de cada animal, sendo que uma foi preenchida com AH Plus, a outra com MTA Fillapex e a última permaneceu vazia (controle negativo). Decorridos os períodos experimentais, os ratos foram mortos e as patas removidas, dissecadas e preparadas para análise histológica. Os cortes foram analisados em microscópico óptico. O infiltrado inflamatório e as zonas de calcificação foram avaliados de forma dicotômica (presente ou ausente). A formação de barreira óssea foi classificada como ausente, parcial ou completa. Testes estatísticos não-paramétricos foram utilizados para a comparação dos dados (p<0,05). Resultados: As comparações entre os períodos experimentais mostraram que aos 7 dias todos os grupos apresentaram menor formação de barreira óssea e que o MTA Fillapex apresentou mais áreas de calcificação em relação aos demais períodos. Nos grupos do AH Plus e do MTA Fillapex, o infiltrado inflamatório reduziu significativamente aos 90 dias. As comparações entre os grupos mostraram mais áreas de calcificação no grupo do AH Plus aos 30 e 90 dias. O grupo controle apresentou menos infiltrado inflamatório aos 30 dias. Não houve diferença significativa entre os grupos na formação de barreira óssea. Conclusões: O cimento endodôntico MTA Fillapex apresentou comportamento biológico satisfatório em contato direto com tecido ósseo de rato. As características do reparo foram semelhantes às do cimento AH Plus, porém o MTA Fillapex não induziu a formação de áreas de calcificação na medula óssea. / Introduction: Biocompatibility is an important property required for a endodontic sealer. This study aimed to analyze bone tissue reactions to MTA Fillapex compared to an epoxy resin-based material in the femur of Wistar rats. Methods: Bone tissue reactions were evaluated in 18 animals after 7, 30 and 90 days (n=6 per period). Three surgical cavities were prepared on femur and filled with 0.1 mL of AH Plus, MTA Fillapex or no sealer (negative control). By the end of each experimental period, six animals were randomly euthanized, the femur was dissected and the surgical cavities separated. The samples were histologically processed and analyzed by light microscope. Inflammatory infiltrate and the calcification zones were evaluated dichotomously; hard tissue barrier was classified as absent, partial or full. Results: Comparison among periods showed that at 7 days all groups presented less hard tissue barrier and MTA Fillapex showed more calcification zones than in other periods. The inflammatory infiltrate significantly reduced at 90 days in AH Plus and MTA Fillapex groups. Comparisons among the groups presented more calcification zones for AH Plus than for the other groups at 30 and 90 days. Control group showed less inflammatory infiltrate at 30 days. There were no singificant diferences to hard tissue barrier among the groups. Data were analyzed by non-parameric tests. Significance level was preset in 0.05. Conclusions: MTA Fillapex presented satisfactory biological behaviour when in direct contact with rat bone tissue. The repair characteristics were similar to those produced by AH Plus, but MTA Fillapex doesn’t induce mineralization in the bone marrow.
332

Pentóxido de nióbio como carga para materiais de base polimérica para uso odontológico

Leitune, Vicente Castelo Branco January 2012 (has links)
O objetivo desta tese foi caracterizar o pentóxido de nióbio (Nb2O5), produzir materiais compósitos de matriz polimérica de uso odontológico e avalia-los. As partículas de Nb2O5 foram caracterizadas com difração de raios-X, microscopia eletrônica de varredura, granulometria a laser, método de Brunauer–Emmett–Teller e espectroscopia micro-Raman. Um adesivo experimental foi desenvolvido com a incorporação de diferentes concentrações de Nb2O5 (0, 5, 10 e 20 %, em peso). Este adesivo foi avaliado quanto à radiopacidade, grau e cinética de conversão, microdureza e a sua interface com a dentina. Um cimento endodôntico experimental de cura dual também foi desenvolvido com a incorporação de diferentes concentrações de Nb2O5 (0, 80, 100 e 120 %, em peso). Este cimento foi avaliado quanto à radiopacidade, escoamento, espessura de película, microdureza e grau de conversão (imediatamente, 7 dias e 14 dias após a fotoativação). A avaliação do Nb2O5 mostrou que as partículas utilizadas apresentavam estrutura monoclínica, com formato irregular, com tamanho médio de 38,16 μm, área de superfície de 3,86 m2/g e estrutura química compatível com pentóxido de nióbio. A radiopacidade e dureza do adesivo aumentaram com a incorporação do Nb2O5 e ele pode ser detectado no interior da interface dentina/adesivo. No cimento endodôntico a incorporação do Nb2O5 também aumentou a radiopacidade e a dureza e reduziu o escoamento apenas no grupo com 120 %. O grau de conversão aumentou até 14 dias após a fotoativação, com exceção do grupo com 80%. Após a caracterização do Nb2O5 e da produção dos materiais experimentais, foi feito o depósito de pedido de patente de invenção. Conclui-se que o pentóxido de nióbio é uma nova e promissora partícula para uso em Odontologia como agente de carga. / The aim of this thesis was to characterize the niobium pentoxide (Nb2O5), to produce resin-based composite for dental applications and evaluate them. Niobium pentoxide was characterised by X-ray diffraction, surface area, particle size, micro-Raman and scanning electron microscopy. An experimental adhesive resin was formulated with 0, 5, 10 and 20 wt% Nb2O5. The formulated adhesive resins were evaluated based on microhardness, degree of conversion, radiopacity and interface (resin/dentin) characterisation by micro-Raman. An experimental dual-cured root canal sealer was produced with a methacrylate-based comonomer blend. Nb2O5 was added at four different concentrations: 0, 80, 100 and 120wt%. Radio-opacity, flow, film thickness, microhardness and degree of conversion (after 1, 7 and 14 days) were evaluated. The particles used in this study presented a monoclinic crystalline phase with typical chemical groups, mean size of 38.16 μm and 3.86 m2/g of surface area. Microhardness and radiopacity increased with higher amounts of Nb2O5, and the particles were able to penetrate into the hybrid layers. Microhardness and radiopacity increased with higher amounts of Nb2O5 in the adhesive resin, and the particles were able to penetrate into the hybrid layers. For the endodontic cement, the radiopacity and microhardness increased with the Nb2O5 addition. The flow was significantly smaller for the 120% group. All groups except those with 80wt% had higher values for degree of conversion after 14 days than immediately after photocuring. After the Nb2O5 characterization and the production of experimental materials, an application for patent was done. Niobium pentoxide is a new and promising filler for dental materials production.
333

Avaliação do comportamento biológico do cimento endodôntico MTA Fillapex em tecido ósseo de ratos / Evaluation of rat bone tissue response to MTA Fillapex

Assmann, Eloísa January 2013 (has links)
Introdução: A biocompatibilidade é uma propriedade importante e necessária a um cimento endodôntico. O objetivo do presente estudo foi fazer uma análise microscópica das reações do tecido ósseo do fêmur de ratos da linhagem Wistar frente ao cimento MTA Fillapex, comparando-as ao cimento AH Plus e ao grupo controle (cavidade vazia), nos períodos de 7, 30 e 90 dias. Materiais e Métodos: Foram utilizados 18 animais, divididos em 3 grupos, de acordo com o período experimental (n=6). Três cavidades foram preparadas no fêmur da pata traseira direita de cada animal, sendo que uma foi preenchida com AH Plus, a outra com MTA Fillapex e a última permaneceu vazia (controle negativo). Decorridos os períodos experimentais, os ratos foram mortos e as patas removidas, dissecadas e preparadas para análise histológica. Os cortes foram analisados em microscópico óptico. O infiltrado inflamatório e as zonas de calcificação foram avaliados de forma dicotômica (presente ou ausente). A formação de barreira óssea foi classificada como ausente, parcial ou completa. Testes estatísticos não-paramétricos foram utilizados para a comparação dos dados (p<0,05). Resultados: As comparações entre os períodos experimentais mostraram que aos 7 dias todos os grupos apresentaram menor formação de barreira óssea e que o MTA Fillapex apresentou mais áreas de calcificação em relação aos demais períodos. Nos grupos do AH Plus e do MTA Fillapex, o infiltrado inflamatório reduziu significativamente aos 90 dias. As comparações entre os grupos mostraram mais áreas de calcificação no grupo do AH Plus aos 30 e 90 dias. O grupo controle apresentou menos infiltrado inflamatório aos 30 dias. Não houve diferença significativa entre os grupos na formação de barreira óssea. Conclusões: O cimento endodôntico MTA Fillapex apresentou comportamento biológico satisfatório em contato direto com tecido ósseo de rato. As características do reparo foram semelhantes às do cimento AH Plus, porém o MTA Fillapex não induziu a formação de áreas de calcificação na medula óssea. / Introduction: Biocompatibility is an important property required for a endodontic sealer. This study aimed to analyze bone tissue reactions to MTA Fillapex compared to an epoxy resin-based material in the femur of Wistar rats. Methods: Bone tissue reactions were evaluated in 18 animals after 7, 30 and 90 days (n=6 per period). Three surgical cavities were prepared on femur and filled with 0.1 mL of AH Plus, MTA Fillapex or no sealer (negative control). By the end of each experimental period, six animals were randomly euthanized, the femur was dissected and the surgical cavities separated. The samples were histologically processed and analyzed by light microscope. Inflammatory infiltrate and the calcification zones were evaluated dichotomously; hard tissue barrier was classified as absent, partial or full. Results: Comparison among periods showed that at 7 days all groups presented less hard tissue barrier and MTA Fillapex showed more calcification zones than in other periods. The inflammatory infiltrate significantly reduced at 90 days in AH Plus and MTA Fillapex groups. Comparisons among the groups presented more calcification zones for AH Plus than for the other groups at 30 and 90 days. Control group showed less inflammatory infiltrate at 30 days. There were no singificant diferences to hard tissue barrier among the groups. Data were analyzed by non-parameric tests. Significance level was preset in 0.05. Conclusions: MTA Fillapex presented satisfactory biological behaviour when in direct contact with rat bone tissue. The repair characteristics were similar to those produced by AH Plus, but MTA Fillapex doesn’t induce mineralization in the bone marrow.
334

Influência da desproteinização dentinária radicular na cimentação de pinos estéticos

Guimarães, Renata Pedrosa 17 December 2012 (has links)
Submitted by Leonardo Freitas (leonardo.hfreitas@ufpe.br) on 2015-04-14T13:58:42Z No. of bitstreams: 2 TESE Renata GUIMARÃES.pdf: 2863665 bytes, checksum: 158d65a6ff45fcb1c843a03fbded403d (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-04-14T13:58:42Z (GMT). No. of bitstreams: 2 TESE Renata GUIMARÃES.pdf: 2863665 bytes, checksum: 158d65a6ff45fcb1c843a03fbded403d (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012-12-17 / CAPES / Objetivo: Avaliar o desempenho de cimentos resinosos frente à desproteinização dentinária através de ensaio de cisalhamento por extrusão de pinos de fibra de vidro. Método: Raízes de 83 pré-molares inferiores humanos foram divididas em 2 grupos conforme o tratamento da dentina (Convencional – recomendações do fabricante e Desproteinização – NaOCl 5,0%/1min). Cada grupo foi dividido em 4 subgrupos segundo o cimento utilizado na cimentação dos pinos de fibra de vidro (Relyx ARC/3M-ESPE; SET/SDI; RelyxU100/3M-ESPE; Cement Post/Angelus). Após 1 semana foi realizado o ensaio push-out. O padrão de falha pós-ensaio foi obtido, de cada corpo de prova, por microscopia óptica. Os dados foram analisados pelo teste F (ANOVA) com comparações de Tukey ou de Tamhane e t-Student (α=5%). Para 3 espécimes foi realizada análise em MEV quanto à morfologia da dentina segundo o tipo de condicionamento. Resultados: A desproteinização influenciou positivamente o desempenho do Cement Post (Terço médio) e Relyx U100 (Terço apical), negativamente para o RelyxARC (Terços cervical e apical) e indiferentemente para o SET. O RelyX U100 e ARC apresentaram os maiores valores de adesão comparados ao SET e Cement Post. O terço cervical apresentou os melhores resultados, com exceção do RelyX U100, no qual o terço apical foi superior. Falhas adesivas foram mais prevalentes no terço cervical (> 50%) e as mistas nos terços médio e apical (>50%). Conclusões: 1. A desproteinização influenciou positivamente a adesão quando empregados o Cement Post (terço médio) e RelyX U100 (terço apical); 2. O Relyx U100 e Relyx ARC obtiveram os melhores resultados
335

Avaliação de cimentos resinosos experimentais contendo diferentes concentrações de um sal derivado do difeniliodônio / Evaluation of experimental resin cements containing different concentrations of a salt derived from diphenyliodonium

Gonçalves, Luciano de Souza 17 August 2018 (has links)
Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T12:43:43Z (GMT). No. of bitstreams: 1 Goncalves_LucianodeSouza_D.pdf: 1422797 bytes, checksum: d08f8aa4d184071d3c75843275b3cdea (MD5) Previous issue date: 2011 / Resumo: O objetivo neste estudo foi avaliar a influência da incorporação de um sal de hexafluorofosfato de difeniliodônio (DFI) nas propriedades de um cimento resinoso experimental. Uma composição à base de monômeros Bis-GMA e TEGDMA, na proporção de 1:1 mol%, foi obtida e a ela adicionadas concentrações de 0 (controle), 0,25, 0,5, 1 ou 2 mol% de DFI, definindo 5 formulações de cimentos resinosos experimentais. O sistema fotoiniciador dos materiais foi composto por 1 mol% de canforoquinona e 2 mol% de metacrilato de dimetilaminoetil. Como inibidor foi usado 0,1 mol% de hidroxibutil tolueno e 60% em peso de partículas silanizadas de vidro de bário-alumínio-silicato foram incorporadas como carga inorgânica. Depois da preparação dos cimentos foram realizados os seguintes ensaios: 1) Cinética da polimerização em tempo real em espectroscopia infravermelha, indicando também o grau de conversão dos cimentos. 2) Resistência à flexão de três pontos e módulo de elasticidade, definido pelo monitoramento do ensaio com software específico. 3) Sorção e solubilidade em água destilada (21 dias). 4) Tensão da contração de polimerização mensurada em máquina de ensaios mecânicos associada a extensômetro. 5) Dureza Knoop avaliada na base e no topo de corpos-de-prova fotoativados diretamente ou através de discos de cerâmica com 3 espessuras diferentes. A análise estatística foi realizada com significância de 5%. Os resultados mostraram que a adição do DFI influenciou as propriedades em todos os ensaios realizados. As formulações de cimentos com DFI apresentaram aumento na cinética da reação, no grau de conversão e na dureza Knoop. Houve aumento significativo na resistência à flexão e no módulo de elasticidade e redução nos valores de sorção de água e perda de massa por solubilidade. Na maioria dos grupos contendo DFI, os valores de tensão da contração de polimerização foram similares ao grupo controle, exceto o grupo 4 com 1 mol% de DFI que apresentou aumento na tensão gerada pela polimerização. Com base nos resultados obtidos foi possível concluir que a adição do DFI influenciou positivamente as propriedades dos cimentos resinosos experimentais e a concentração de 0,5 mol% parece ser a mais conveniente para a formulação desses cimentos resinosos estudados. / Abstract: The aim of this study was to evaluate the effect an onium salt -diphenyliodonium hexafluorphosphate (DPI) - on selected properties of experimental resin cement. A model Bis-GMA/TEGDMA comonomer blend (1:1 molar ratio) was obtained and DPI added at concentrations of 0 (control), 0.25, 0.5, 1 or 2 mol%, resulting in five experimental resin cements. The photoinitiator system was composed by 1 mol% of camphorquinone and 2 mol% of dimethylaminoethil methacrylate. 0.1mol% of hydroxyl butyl toluene was used as a inhibitor and the cements were loaded with a 60% mass fraction of silanated Ba-AI-Si glass fillers. The following analyzes were carried out: 1) real-time polymerization kinetics using near-infrared spectroscopy, 2) flexural strength and flexural modulus using a three-point beinding test, 3) water sorption and solubility after immersion for 21 days, 4) polymerization stress on a mechanical testing machine, and 5) Knoop hardness on the top and bottom surfaces of cement discs light-activated through different ceramic thicknesses. Data were statistically analyzed (5%). The results showed the addition of DPI had influence on the resin cements for all analyses. DPI-containing materials showed improved polymerization kinetics and degree of conversion, as well as higher hardness. A significant increase in flexural strength and modulus, and decrease in water sorption/solubility was detected. Most of materials containing DPI showed polymerization stress values comparable to the control group, except for the material containing 1 mol% of DPI (G4), which yielded higher stress. Based on these results and within the limitations of the study, it was possible to conclude that the addition of DPI has positive influence on the properties of the experimental resin cement; the 0.5 mol% concentration seems to be the most appropriate and efficient for the formulation of these resin cements. / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
336

Avaliação quantitativa da microinfiltração em cavidades de classe V restauradas com materiais hibridos de ionomero de vidro/resina composta

Magalhães, Claudia Silami de 14 November 1997 (has links)
Orientador: Monica Campos Serra / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T00:07:36Z (GMT). No. of bitstreams: 1 Magalhaes_ClaudiaSilamide_M.pdf: 2310367 bytes, checksum: abc110f4c4d7e29799ce02a031a83b58 (MD5) Previous issue date: 1997 / Resumo: O objetivo deste estudo "in vitro" foi avaliar quantitativamente a microinfiltração em cavidades de classe V restauradas com materiais híbridos de ionômero de vidro/resina composta, comparando-os com um cimento de ionômero de vidro e com um sistema de resina composta/adesivo dentinário. Foram preparadas cavidades cilíndricas na superfície radicular de 105 dentes humanos extraídos, a cerca de 4 mm da junção amelo-cemeotária. Os dentes foram divididos aleatoriamente em cinco grupos, cada um contendo 21 unidades experimentais. Os grupos controles foram restaurados com um cimento de ionômero de vidro ou com um sistema de resina composta/adesivo dentinário. Os grupos experimentais foram restaurados com três materiais híbridos de ionômero de vidro/ resina composta, sendo dois cimentos de ionômero de vidro modificados por resina e uma resina composta modificada por poliácido. Todos os dentes foram termociclados por 500 vezes, entre temperaturas de 5 ± 2 °C e 55 ± 2 °C, com um tempo de permanência de 1 minuto em cada banho. Em seguida, os espécimens foram imersos em solução aquosa de azul de metileno a 2%, por 24 horas, a 37 °C. A microinfiltração foi quantificada através de espectrofotometria e expressa em micrograma de corante por mililitro de solução. A análise estatística dos dados não indicou diferença significante entre os materiais (^2=5,37, a > 0,05). Sob as condições experimentais utilizadas neste estudo, pôde-se concluir que o desempenho dos materiais híbridos de ionômero de vidro/resina composta, frente à microinfiltração, foi similar ao do cimento de ionômero de vidro e ao do sistema de resina composta/adesivo dentinário / Abstract: The purpose of this "in vitro" study was to quantify the marginal leakage of three glass ionomer - composite resin hybrid materials in dentin cavities, compared with a glass ionomer cement and a bonded composite resin system. Standardized cylindrical class V cavities were prepared on root fecial surface of 105 extracted human uniradicular teeth, about 4 mm below the CEJ. The teeth were randomly assigned into five groups of 21 each. Control groups were restored with either a glass-ionomer cement or a bonded composite resin system. The experimental groups were restored with three glass-ionomer composite resin hybrid materials. All materials were manipulated according to manufacturers' instructions. The teeth were stored in distilled water at 37" C for 24 hours. After this storage period, the restorations were finished and polished with abrasive discs. All teeth were thermally stressed for 500 cycles with a dwell time of 1 min at 5° + 2 °C and 55° ± 2 °C, and subjected to dye penetration test (2 % methylene blue at 37 °C for 24 hours). The microleakage was quantified by spectrophotometry and was expressed as ja.g dye / mL. Statistical analysis indicated no significant differences among the five groups (x2-5.37, a > 0,05). Hence, it was concluded that glass ionomer -composite resin hybrid materials, glass ionomer cement and bonded composite resin system microleakage performances were similar, under the experimental conditions / Mestrado / Dentística / Mestre em Clínica Odontológica
337

Avaliação histologica da reação do tecido subcutaneo de ratos apos a implantação de cimentos endodonticos

Gomes Filho, João Eduardo 23 April 2001 (has links)
Orientador : Francisco Jose de Souza Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T04:53:03Z (GMT). No. of bitstreams: 1 GomesFilho_JoaoEduardo_D.pdf: 3941547 bytes, checksum: 7475d7da57af1099a7407a3a7e94295f (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo foi avaliar in vivo a biocompatibilidade dos cimentos endodônticos Endométhasone, Pulp Canal Sealer e AH-Plus, após a implantação em tecido subcutâneo de ratos. Vinte e quatro ratos Wistar-Furth foram utilizados. Cada cimento foi colocado no interior de tubos de polietileno e implantados em locais específicos no subcutâneo do dorso do animal. Os blocos de tecido foram removidos após 3, 7 e 30 dias, fixados e processados pelo método de inclusão em glicol metacrilato para avaliação microscópica. Observou-se no terceiro dia, uma resposta inflamatória mais intensa, com células do infiltrado agudo para todos os cimentos, sendo que o cimento Pulp Canal Sealer apresentou uma reação mais branda. No sétimo dia, o tecido já se apresentava mais organizado principalmente para o cimento AH-Plus, o qual permitiu o início de formação de cápsula fibrosa na embocadura do tubo. No trigésimo dia, todos os cimentos apresentaram formação de cápsula fibrosa, com poucas células inflamatórias crônicas. Neste período mais longo, o cimento Pulp Canal Sealer apresentou um estágio mais avançado de organização tecidual, enquanto os cimentos AH-Plus e Endométhasone não diferiram muito entre si, mostrando ainda um leve grau de inflamação / Abstract: The aim of this study was to evaluate the in vivo biocompatibility of Endométhasone, Pulp Canal Sealer e AH-Plus root canal sealers, after implantation in rat connective tissue. Twenty-four Wistar-Furth rats were used. Each sealer was placed in polyethylene tubes and implanted into specific dorsal subdermal tissues sites. Implants were removed afier 3, 7 and 30 days, fixed and processed by glycol methacrylate method to be microscopically examined. On the third day, it was possible to observe a severe reaction with acute inflammatory cells with ali sealers, but a milder reaction was identified with Pulp Canal Sealer. The organization of the tissue was clearer, specially with AH-Plus, with reduction of the severity of the reaction on the ih day. The connective tissue with a few inflammatory cells was present with ali sealers on the 30th day. In this longer time, with Pulp Canal Sealer was the sealer, the tissue was more organized, while Endométhasoe and AH-Plus did not differ each other and they showed a milder persistent reaction / Doutorado / Endodontia / Doutor em Odontologia
338

Infiltração marginal em restaurações de amalgama de prata sob influencia de formas de condensação e uso de materiais intermediarios na interface marginal

Pinto, Marcia Bueno 15 December 2000 (has links)
Orientadores: Simonides Consani, Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T05:41:56Z (GMT). No. of bitstreams: 1 Pinto_MarciaBueno_D.pdf: 21339887 bytes, checksum: e010eea03df0ee50f3c87d24d25c9142 (MD5) Previous issue date: 2001 / Resumo: A proposta deste estudo "in vitro" foi avaliar a capacidade de selamento de restaurações de amálgama de prata submetidas à três técnicas de condensação (manual, mecânica e ultra-sônica) utilizando-se, como materiais intermediários, adesivo dentinário, cimento de ionômero de vidro modificado por resina, cimento resinoso, verniz copal e, como controle, somente amálgama. Foram preparadas cavidades tipo classe V na raiz de 210 dentes incisivos de bovinos, com 4 mm no maior tamanho no sentido cervico-oclusal e mésio-distal e 1,5 mm de profundidade com todas as margens localizadas em dentina. Os dentes foram divididos em 5 grupos com 42 dentes em cada um sendo que um dos grupos foi utilizado como controle, sem material intermediário (G1) e cada um dos outros quatro grupo recebeu um material intermediário diferente e as três formas de condensação. Antes da condensação do amálgama (Dispersalloy) as cavidades foram tratadas de acordo com as instruções dos fabricantes com Copalite (G2), Vitremer (G3), Enforce + Prime & Bond 2.1 (G4) e Prime & Bond 2.1(05). As amostras ficaram armazenadas em solução salina durante 30 dias e, a cada 15 dias, foi realizado uma termociclagem que constou de 500 ciclos cada, com tempo de 15 segoem cada banho e temperaturas de 5°C e 55° C. Depois da fadiga térmica as amostras foram mergulhadas em solução de fucsina básica 0,5% à temperatura ambiente durante 24h depois das quais foram lavadas e incluídas em resina acrílica para seccionamento em máquina específica (LABCUT). De cada restauração foram obtidos 3 ou 4 cortes e aquele que apresentou a maior penetração de corante, foi fotografado no Estereomicroscópio e avaliado em graus que variaram entre "0" (sem infiltração) até "3" (máxima infiltração). Os resultados foram submetidos à testes estatísticos de 'X POT. 2¿ e pode-se observar que as formas de condensação não afetaram significativamente a quantidade de infiltração observada. No entanto, quando consideramos apenas a presença ou não de infiltração, os testes estatísticos mostraram que a condensação manual foi superior as outras duas (mecânica e ultrassônica) mostrando uma microinfiltração significativamente menor. Também foi possível verificar que as amostras com Prime & Bond 2.1 e o grupo sem material intermediário mostraram significativamente menos infiltração do que o grupo com Enforce + Prime & Bond 2.1. O grupo com Copalite mostrou um pior resultado apenas quando comparado ao grupo controle sendo semelhante a todos os outros grupos testados. O grupo com Vitremer mostrou-se significantemente melhor do que grupo com Enforce + Prime & Bond 2.1 / Abstract: The purpose of this "in vitro" study was to determine the sealing ability of amalgam restorations submit to 3 condensation techniques underlined with adhesive systems, resin modified glass ionomer, copal varnish and amalgam only, wich was use as control. Class V cavities were made in 210 bovine incisor teeth. The cavities had 4mm in diameter and 1.5mm in depth and were prepared at the root in such way that the margins were established in dentin. Before packing the amalgam (Dispersalloy), the cavities were treated, according to the manufacturer's direction, with Copalite Varnish, Vitremer, Enforce + Prime & Bond 2.1 and Prime & Bond 2.1.The sample remained stored in saline solution for a months and in the meantime they were thennocycled. Each thennocycling comprised of 500 cycles between 5° and 55° C with a dwell time of 15 seconds. After the tennal stress the sample were immersed in 0.5% basic fucsin solution 24 h. and washed. The teeth were embedded in resin acrylic and sectioned in a cutting machine (LABCUT). Three to four buccal-lingual cuts, including the restoration were obtained and the microleakage scored from "0" (no leakage) to "3" (maximum leakage). The highest score for each tooth was considered. Chi-square test was applied to the results and the following observations could be drawn: the 3 different condensation techniques did not significantly affect microleakage. It was also possible to observe that the specimens with Prime & Bond 2.1 and control grup showed signficatly less leakage the Enforce + Prime & Bond 2.1. No significantly difference between Copalite and the other groups, except the was obsered G1(control). The Vitremer was only significantly better than G4 / Doutorado / Doutor em Materiais Dentários
339

Influencia do modo de ativação, da ciclagem mecanica e da ceramica na resistencia a tração diametral de cimentos resinosos / Influence of activation modes, mechanical fatigue and ceramic on resin cements' diametral tensile strength

Paes, Paula Nunes Guimarães 02 May 2009 (has links)
Orientador: Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T01:34:04Z (GMT). No. of bitstreams: 1 Paes_PaulaNunesGuimaraes_M.pdf: 8634173 bytes, checksum: 841ceeadf71622e4274b862220cdb566 (MD5) Previous issue date: 2009 / Resumo: O objetivo deste estudo foi avaliar o efeito dos métodos de ativação e da fadiga mecânica sobre a resistência à tração diametral de cimentos resinosos duais. Pastas base e ativadora do RelyX ARC, Enforce, Nexus 2 e RelyX UNICEM foram manipuladas e inseridas em matrizes cilíndricas de silicona de adição (4 x 2 mm) e distribuídas em grupos de acordo com a técnica de ativação em: 1- Sem fotoativação (ativação química); 2- Fotoativação direta (ativação Dual); 3- Fotoativação através da cerâmica. Após armazenamento por 24 horas em água destilada a 37ºC, metade das amostras de cada grupo (n=10) foram submetidos a 30.000 ciclos mecânicos, com freqüência de 1 Hz e carga de 12 N. As amostras não cicladas permaneceram armazenadas em água destilada em estufa a 37ºC por 32 h após a manipulação, para que fossem testadas com o mesmo intervalo de tempo que as amostras cicladas. Em seguida, todas as amostras foram submetidas ao ensaio de Resistência à Tração Diametral (RTD) em máquina universal de ensaios INSTRON, com velocidade de 0,5 mm/min. Os dados de RTD (MPa) para os modos de ativação química, dual indireta e dual direta foram submetidos à análise de Variância e ao teste de Tukey (5%) e mostraram que apenas os fatores modo de ativação e cimento apresentaram interação significativa. O fator ciclagem mecânica e a interação tripla não obtiveram interação significativa. Os valores da interação dos fatores cimento e modos de ativação química, dual indireta e dual direta respectivamente foram: RelyX ARC (49,68 ± 8,42; 63,43 ± 6,92 e 55,12 ± 5,16), Enforce (49,12 ± 3,89; 56,96 ± 6,45 e 56,42 ± 8,88), RelyX ARC (28,12 ± 11,21; 40,10 ± 4,39 e 37,44 ± 6,49) e Nexus 2 (61,89 ± 11,21; 62,56 ± 10,93 e 59,26 ± 9,47). A análise dos resultados após o teste de Tukey mostrou que o cimento Nexus 2 não apresentou aumento nos valores de RTD quando ativado pela luz em relação à polimerização química. Os demais cimentos apresentaram valores maiores quando fotoativados de forma direta ou indireta, em relação aos valores alcançados pelo modo de polimerização química, com exceção do cimento RelyX ARC que obteve os mesmos valores quando ativado de forma dual direta e polimerizado quimicamente. A interposição do disco de cerâmica durante a fotoativacão alterou os valores de resistência à tração diametral apenas para o cimento RelyX ARC. A ciclagem mecânica não afetou a resistência à tração diametral de nenhum cimento resinoso dual avaliado e a composição de cada cimento resinoso dual, assim como o seu modo de ativação, foram determinantes para a obtenção da resistência à tração diametral dos mesmos. / Abstract: The aim of this study was to evaluate the effect of the activation methods and the mechanical fatigue on diametral tensile strength of dual resin cements. Base and catalyst pastes of the cements RelyX ARC, Enforce, Nexus 2 and RelyX UNICEM were mixed and inserted into cylindrical silicon moulds (4 x 2 mm) and divided in groups according to their activation methods: 1) without photoactivation (chemical activation); 2) direct curing (dual ativation); 3) light activation through porcelain disk. After being stored for 24 hours in distillated water at 37ºC, half of the samples of each group (n=10) were subjected to 30,000 mechanical cycles at 1 Hz frequency and 12 N load. The samples not cycled remained in distillated water at 37ºC for 32 h after the mixing, so they were tested with the same time that the other fatigued samples did. Then, the samples were subjected to Diametral Tensile Strength (DTS) in Instron universal machine with 0,5 mm/min speed. The data of the Diametral Tensile Strength (MPa) obtained for each cement in chemical, indirect dual and direct dual modes of activation were submeted to three-way analysis of variance and Turkey's Student Range Test (5%) and showed that only the activation methods and the cement type presented significant difference. Mechanical fatigue and triple factors interation didn't present significant difference. The data of the cement factor with chemical activation, indirect curing and direct curing was respectively: RelyX ARC (49.68 ± 8.42; 63.43 ± 6.92 e 55.12 ± 5.16), Enforce (49.12 ± 3.89; 56.96 ± 6.45 and 56.42 ± 8.88), RelyX ARC (28.12 ± 11.21; 40.10 ± 4.39 and 37.44 ± 6.49) and Nexus 2 (61.89 ± 11.21; 62.56 ± 10.93 and 59.26 ± 9.47). After Turkey's test, the data showed that the cement Nexus 2 didn't present increase in the DTS values when it was light actived comparing to chemical curing. The others cement presented higher values when directly or indirectly photoactivated compared with the values obtained with chemical activation mode. The exception was the RelyX ARC cement that obtained the same data when it was direct cured and chemical activated. The interposition of porcelain disk during the photoactivation did alter the DTS values only for the RelyX ARC cement. However, the mechanical fatigue didn't alter the DTS values of any dual resin cement tested. Each dual cement composition, as their activation mode, was fundamental in order to obtain its DTS values. / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
340

Efeito da viscosidade e modo de ativação na resistencia de união a dentina, grau de conversão e resistencia flexural biaxial de cimentos resinosos duais / Effect of viscosity and activation mode on the bond strength to dentin, conversion degree and biaxial flexure strength and modulus of dual resin cements

Di Francescantonio, Marina 13 August 2018 (has links)
Orientador: Marcelo Giannini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T02:04:38Z (GMT). No. of bitstreams: 1 DiFrancescantonio_Marina_M.pdf: 16720831 bytes, checksum: ce2d1ee161bca05d6b15b3e0a9eaeedd (MD5) Previous issue date: 2009 / Resumo: As propriedades mecânicas dos cimentos resinosos são influenciadas pelo tipo e composição da matriz resinosa, tipo e tamanho das partículas de carga, modo e grau de conversão dos monômeros em polímeros, e a viscosidade é uma propriedade que está intimamente ligada a esses fatores. Os objetivos deste estudo foram avaliar a influência da viscosidade (alta e baixa) e modo de polimerização (polimerização dual e autopolimerizado) de cimentos resinosos duais (Nexus 2/ Kerr, Corp e Variolink II/ Ivoclar-Vivadent): na resistência de união da restauração à dentina (RU), no grau de conversão (GC) e na resistência flexural biaxial (RFB). Para o teste de RU, substratos dentinários de cinqüenta e seis terceiros molares humanos foram utilizados para o ensaio de microtração através da cimentação de uma peça protética do material de resina composta indireta e estes foram foto-ativados ou não segundo cada grupo experimental. Após 24 horas, os dentes foram secionados para obter espécimes em forma de palitos (de área de secção transversal de 1.0 mm²), que foram testados em tração a uma velocidade de 0,5 mm/ mim (4411/Instron). Os resultados foram analisados por ANOVA 3 fatores e teste Tukey (p=0,05). Para a análise do GC, os cimentos foram aplicados na superfície da unidade de reflectância total atenuada acoplada ao espectrômetro infravermelho (Nicolet Instrument Corp, Madson, Wisconsin, EUA) sendo foto-ativados ou não. Espectros foram obtidos após 5 minutos e 24 horas. O cálculo do grau de conversão foi realizado através da análise da mudança na proporção entre as alturas dos picos das ligações duplas de carbono alifática e aromática. Os dados foram submetidos a ANOVA 3 fatores e teste de Tukey (p=0,05). Para o ensaio de RFB, noventa e seis discos de cimentos resinosos (0,5mm de espessura/ 6mm de diâmetro) foram preparados utilizando moldes de silicone de adição (n=12) e foram foto-ativados ou não segundo os grupos experimentais. Após 5 dias, os discos foram testados em dispositivos de ensaio de flexão biaxial em máquina de ensaio universal (1,27 mm/min, Instron 5844) e os dados analisados estatisticamente por ANOVA 3 fatores e teste Tukey(p=0,05). Para a RU, a polimerização dual (foto + autopolimerização) aumentou significantemente os valores médios para os cimentos resinosos em baixa viscosidade para ambos os cimentos resinosos duais utilizados no estudo. Em relação o GC, a foto-ativação e quando o GC foi mensurado após 24 horas, aumentaram significativamente o GC para ambos os cimentos resinosos. A versão em baixa viscosidade apresentou maior GC que os em alta viscosidade, para as duas formas de polimerização. No teste RFB, a foto-ativação aumentou significantemente a resistência e módulo de flexão. A versão em alta viscosidade quando foto-ativada mostrou maior resistência flexural que em baixa viscosidade, enquanto a viscosidade não alterou os valores médios de módulo flexural. Pode-se concluir que a foto-ativação é necessária durante a cimentação de restaurações indiretas, para garantir adequadas propriedades físico-químicas, e a utilização de cimentos resinosos em diferentes viscosidades pode modificar os valores médios de RFB, GC e RU à dentina. / Abstract: The mechanical properties of resin cements may be influenced by the type and monomer composition, type and filler size, mode, and degree of conversion, which are all associated with resin viscosities. The aim of this study was to evaluate the influence of resin cement viscosity (high and low) (Nexus 2/ Kerr, Corp and Variolink II/ Ivoclar-Vivadent) and the curing mode (dual and chemical activation) on the bond strength to dentin, on the degree of conversion and biaxial flexural strength. For microtensile bond strength test, two bonding agents and their respective resin cement, occlusal dentin surfaces of fifty-six human third molars were used for the testing and the resin cements were applied to pre-cured resin composite discs, which were fixed to dentin surfaces, simulating an indirect restoration. The restored teeth were either light-activated or allowed to self-cure, according to experimental groups. After 24 hs, the teeth were sectioned to obtain bonded beams specimens (1.0 mm²). Each specimen was tested in tension at a crosshead speed of 0.5 mm/min (4411/Instron). Data (MPa) was analyzed by 3- way ANOVA and Tukey's Tukey's test (p=0.05). To evaluate the degree of conversion, the resin cements were applied to surface of a horizontal attenuatedtotal- reflectance unit (Nicolet Instrument Corp, Madson, Wisconsin, EUA) and were polymerized using one of two conditions: self-cure (SC) or direct light exposure (600 mW/cm2, XL3000/3M ESPE) and infrared spectra were obtained after 5 minutes and 24 hours. The degree of conversion was calculated using standard techniques of observing changes in aliphatic-to-aromatic peak ratios pre- and postcuring. Data were analyzed by 3-way repeated measure ANOVA and Tukey's test (p=0.05). For the biaxial flexural strength, forty-eight resin cement discs of each product (0.5 mm thick and 6.0 mm in diameter) were created using silicon impression material molds (n=12) and were either light activated or not, according to experimental groups. After 5 days, the specimens were subjected to the biaxial flexure test in a universal testing machine (1.27 mm/min, Instron 5844) and the data ware statistically analyzed by 3-way ANOVA and Tukey's post-hoc test (p=0.05). For bond strength testing, the dual curing mode increased the bond strength for the low viscosity resin cements for both dual resin cement used in this study. For the degree of conversion, the light activation, after 24h, significantly increased the degree of conversion for both resin cements, and the low viscosity version from dual cure or self-cured groups exhibited higher degree of conversion than high viscosity version. Regarding biaxial flexural strength, the light-activation significantly increased flexural strength and modulus, and the high viscosity versions of dual cure groups exhibited higher flexural strength than their low viscosity versions, while the viscosity of resin cements did not influence the modulus. In conclusion, the light-activation of dual resin cements is required in indirect restorations, to provide proper mechanical and chemical properties, and the use of resin cements with different viscosities may change the bonding biomechanical characteristics of indirect restorations. / Mestrado / Dentística / Mestre em Clínica Odontológica

Page generated in 0.0838 seconds