• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 260
  • 65
  • 20
  • 12
  • 12
  • 12
  • 12
  • 11
  • 10
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 370
  • 370
  • 260
  • 242
  • 199
  • 69
  • 57
  • 55
  • 51
  • 47
  • 45
  • 41
  • 40
  • 38
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

Influência de tratamentos superficiais e termociclagem na resistência da união resina/metal

Almilhatti, Hercules Jorge [UNESP] 27 April 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-04-27Bitstream added on 2014-06-13T19:44:48Z : No. of bitstreams: 1 almilhatti_hj_dr_arafo.pdf: 2065564 bytes, checksum: 9ca5fe747a7a70b66a300c7564a4ad19 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo teve como objetivo avaliar a efetividade de quatro condicionadores de metal (Metal Photo Primer, MPP; Cesead II Opaque Primer, OP; Targis Link, TL e Siloc, S) aplicados sobre diferentes superfícies das ligas de Ni-Cr, Co-Cr e do metal Ti Cp. Após o polimento metalográfico e jateamento com Al2O3, foram obtidos três grupos experimentais para cada metal : Grupo polimento (P) - controle; Grupo (J50), jateado com Al2O3 de 250 um. A esses grupos foram aplicados os condicionadores e as resinas opaca e de revestimento estético (Artglass). Decorridos 24 horas de armazenamento em água a 37ºC, cada grupo foi dividido em dois grupos e submetidos aos ensaios mecânicos de cisalhamento (0,5 mm/min.), um antes e outro após 500 ciclos térmicos (60ºC e 4ºC). As superfícies fraturadas foram analisadas e o padrão de falhas determinado. Adicionalmente foram feitas análises de MEV e EDS. Seguem os resultados para cada metal: Liga de Ni-Cr: para os Grupos P e J50, não foram observadas diferenças (p>0,05) nos valores médios de tensão de cisalhamento entre os condicionadores OP e TL e entre MPP e S, sendo maiores as médias dos dois primeiros. Não foram encontradas diferenças (p>0,05) entre as médias de tensão para os condicionadores do Grupo J250. No entanto, esses valores foram superiores aos do Grupo J50. Após a termociclagem, as médias para os condicionadores OP, S e TL não apresentaram aumento significante (p>0,05), enquanto a média para o MPP aumentou (p<0,05). Liga de Co-Cr, para o Grupo P, não foram observadas diferenças (p>0,05) nos valores médios de tensão entre os condicionadores OP e TL e entre MPP e S, sendo superiores as médias dos dois primeiros. As médias de tensão para o Grupo J250 foram estatisticamente maiores às do Grupo J50,... / The purpose of the study was to evaluated the effect of three adhesive primers (Metal Photo Primer, MPP; Cesead II Opaque Primer, OP; Targis Link, TL) and a bonding system (Siloc, S) on the shear bond strength between a prosthetic composite material (Artglass) to Ni-Cr alloy (Wiron 99), Co-Cr alloy (Wironit), and CP Ti (Tritan). Disk patterns were cast of the 3 alloys. All the disk surfaces were abraded with No. 80, 320, and 600 SiC paper, respectively and three different surface treatment were applied: No. 600 SiC polishing, P; 50 mm Al2O3 sandblasting, S50; 250 mm Al2O3 sandblasting, S250. The composites (Artglass opaque and dentin) were applied using a cylindrical stainless steel split according to manufacturer's instructions then light polymerized. Specimens without primer and bonding system were also prepared as control. The specimens were stored in water a 37oC for 24 h and then shear bond strengths were determined both before and after immersed alternately in water baths at 4oC and 60oC for 15 seconds each for up to 500 thermal cycles before shear mode testing at a crosshead speed of 0.5 mm/min. Data were statistically analyzed using 3-way ANOVA and 1-way ANOVA, followed by Tukey multiple range intervals calculated at the 0.05 significance level. Fractured interfaces were analyzed by use of light microscopy and SEM. Results: Ni-Cr alloy: The bond strength of the P-OP/J50-OP group and P-TL/J50- TL group were statistically comparable (p>0,05) and exhibited greater strength than the P-MPP/J50-MPP group and P-S/J50-S (p<0,05). No significant differences were found among the four conditioners for J250 group (p>0,05), and these group showed the greater strength than the J50 group (p<0,05). After thermocycling, no significant differences (p>0,05) were found among the three primers (OP, S, TL) and the bond strength of MPP increased...(Complete abstract, click electronic access below)
272

Influência da composição de resinas compostas no grau de conversão e degradação hidrolítica /

Jassé, Fernanda Ferreira. January 2010 (has links)
Resumo: Numerosos tipos e marcas comerciais de resinas compostas são constantemente introduzidos no mercado odontológico, em função de modificações na composição, tipo, formato e quantidade das partículas inorgânicas, assim como na porção orgânica. Sempre, com a finalidade de proporcionar propriedades mecânicas e estéticas superiores aos materiais, aumentando dessa forma sua longevidade. Assim, o propósito neste estudo foi avaliar o grau de conversão (GC) pelo método FT-IR e a degradação hidrolítica por meio do teste de dureza Vickers (dV), de duas resinas compostas (uma nanoparticulada e uma micro-híbrida). Para isso, oito espécimes (4 mm de diâmetro x 2 mm de espessura, ISO 4049) de cada material foram confeccionados para cada teste. As resinas compostas foram inseridas em única porção na matriz metálica e fotoativadas com aparelho LED (Celalux, Voco®, 776 mW/cm²), por 40 segundos. Dezesseis leituras de dV (8 no topo e 8 na base) foram realizadas para cada espécime em durômetro digital MMT-3 (Buehler Lake Bluff, Illinois USA), utilizando carga de 50 gf aplicada durante 30 segundos, em intervalos de tempo prédeterminados: imediatamente após fotoativação (controle), 24, 48, 72 horas, 7, 14, 21, 30 dias e 6 meses. Logo após a fotoativação foi feita a medida da dureza inicial e os espécimes foram então imersos em saliva artificial a 37°C. Para o GC (%), os espécimes foram triturados, prensados com KBr e analisados em espectrofotômetro FT-IR (Nexus-470). Os resultados foram submetidos à análise estatística e permitiram concluir que: não foi observada diferença entre as resinas quanto ao grau de conversão; a proporção entre as medidas de dureza de topo e base foi semelhante para os dois materiais, tendo sido mantida ao longo de todo o tempo experimental; a resina Z-250 apresentou os maiores valores de dureza tanto na superfície de topo quanto na de base... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Numerous types and brands of composite resins are constantly introduced into the dental market, due to changes in the composition, type, shape and quantity of inorganic particles as well as the organic portion. Always with the aim of providing superior mechanical and aesthetic properties to materials, thereby increasing their longevity. Thus, the purpose of this study was to evaluate the degree of conversion (DC) and hydrolytic degradation through the Vickers hardness test (hV) of two composites (a nanofilled and a microhybrid). For this, eight specimens (4 mm diameter x 2 mm thick, ISO 4049) of each material were prepared for each test. The composites were inserted into single increment in the metallic matrix and photoactivated with a LED unit (Celalux, Voco ®, 776 mW / cm ²) for 40 seconds. Sixteen hV readings (8 on each top and bottom surfaces) were performed for each specimen in MMT-3 digital hardness tester (Buehler Lake Bluff, Illinois USA), using load of 50 gf applied for 30 seconds, at predetermined intervals: immediately after polymerization (control), 24, 48, 72 hours, 7, 14, 21, 30 days and 6 months. After curing, initial hardness measurements were performed and the specimens were immersed in artificial saliva at 37 °C. For the DC (%), the specimens were ground, pressed with KBr and analyzed by FT-IR spectrophotometer (Nexus-470). The results were subjected to statistical analysis and concluded that: there was no difference between the resins for degree of conversion; the ratio between top and bottom hardness values was similar for both materials and was maintained throughout the experimental period; the composite resin Z-250 showed the highest hardness values in both the top surface as the bottom throughout the evaluation period. The materials tested showed no evidence of hydrolytic degradation in a significant way, in a six-month storage-time in artificial saliva / Orientador: José Roberto Cury Saad / Coorientador: Alessandra Nara de Souza Rastelli / Banca: Marcelo Ferrarezi de Andrade / Banca: Rafael Leonardo Xediek Consani / Mestre
273

Influência dos métodos de fotoativação e fontes de luz nas propriedades de diferentes resinas compostas /

Costa, Simone Xavier Silva. January 2010 (has links)
Resumo: O objetivo deste trabalho, dividido em três estudos, foi avaliar: (1) a influência da utilização de diferentes fontes de luz e métodos de fotoativação sobre o grau de conversão e a contração de polimerização de uma resina composta nanoparticulada; (2) a influência da utilização dos diferentes métodos de fotoativacao, disponibilizados por aparelhos LED de 2a geração, sobre a contração volumétrica das resinas compostas microhíbrida e nanopartículada e (3) as propriedades térmicas e o grau de conversão das resinas compostas microhíbrida e nanopartículada, submetidas aos diferentes métodos de fotoativação disponibilizados por aparelhos LED de 2a geracao. No primeiro estudo, o grau de conversão (GC) foi avaliado pelo metodo da espectroscopia infravermelha transformada de Fourier (FT-IR) e as forças de contração (C) mensuradas em máquina de ensaios universal (EMIC). Os dados obtidos para o GC e C foram analísados estatísticamente pelo teste da análise de variancia (ANOVA), sendo que para as forças de contração, a correção de Welch e o teste Tamhane também foram empregados. No segundo estudo, a contração volumétrica foi avaliada por um mecanismo de vídeo e imagem (AcuvolR/Bisco) e os dados obtidos foram análisados estatísticamente pelos testes ANOVA e Tukey. No terceiro estudo, o método da calorimetria exploratória diferencial foi empregado para avaliar a temperatura de transição vitrea (Tg) e de degradação dos materiais e o GC por FTIR. Os dados relativos ao GC foram análisados estatísticamente pelos testes ANOVA e Tukey. Os resultados demonstraram diferenças na contração de polimerização de acordo com o método de fotoativação empregado. No primeiro e segundo estudos, mesmo empregando diferentes metodologias, o método de fotoativação contínuo apresentou os maiores valores de contração. Por outro lado,o GC não... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this work, divided into three studies, was evaluate: (1) the influence of different light sources and photo-activation methods on degree of conversion and polymerization shrinkage of a nanocomposite resin; (2) the influence of different photo-activation methods, available by the 2nd generation LED light-curing units, on the volumetric shrinkage of microhybrid and nanocomposite resins and (3) thermal properties and degree of conversion of microhybrid and nanocomposite resins submitted to different photo-activation methods available by 2nd generation LED light-curing units. In the first study, degree of conversion (DC) was evaluated by Fourier transform infrared spectroscopy (FT-IR) and shrinkage forces (S) were measured in a universal testing machine (EMIC). The data obtained for DC and S were analyzed by Analysis of Variance test (ANOVA) and for S Welch's correction and Tamhane's tests were also employed. In the second study, volumetric shrinkage was evaluated by video-imaging device (AcuvolR/Bisco) and data were analyzed by ANOVA and Tukey's test. In the third study, differential scanning calorimetry was used in order to observe glass transition temperature (Tg) and degradation peak of the materials and DC was evaluated for FT-IR. The DC data were analyzed by ANOVA and Tukey's test. The results showed differences in the polymerization shrinkage according to photo-activation method employed. In the first and second studies, the continuous photo-activation methods presented the highest values for shrinkage even though different methodologies were used to assess. Moreover, DC was not influenced by the photo-activation method but was influenced by light sources. The lowest DC values were observed for halogen light-curing unit. In the second study beyond the influence of the photo-activation... (Complete abstract click electronic access below) / Orientador: Marcelo Ferrarezi de Andrade / Coorientador: Alessandra Nara de Souza Rastelli / Banca: Silmara Aparecida Milori Corona / Banca: Denise Pedrini / Banca: Osmir Batista de Oliveira Junior / Banca: José Roberto Cury Saad / Doutor
274

Avaliações clínica e clínica/fotográfica de restaurações adesivas, realizadas em lesões cervicais não cariosas : efeitos dos materiais restauradores, tipos e tempos de avaliação /

Oliveira, Fernanda Garcia de. January 2010 (has links)
Resumo: O objetivo desse trabalho foi avaliar através das análises clínica e clínica/fotográfica o comportamento de 124 restaurações de lesões cervicais não cariosas, realizadas com uma resina composta ou com um ionômero de vidro modificado por resina, nos períodos de 6 e 12 meses após suas realizações. Foram formados 3 grupos de estudo, de acordo com os materiais e técnicas empregadas. Previamente à aplicação dos materiais adesivos, todos os dentes receberam o condicionamento com ácido fosfórico a 37% em esmalte e dentina. Após, os dentes pertencentes ao grupo I receberam o sistema adesivo convencional Scotchbond Multi Uso, seguido pela resina composta Filtek Z350; os do grupo II apenas o material ionomérico modificado por resina Fuji II L.C., enquanto que os do grupo III foram restaurados com o mesmo material ionomérico, entretanto, previamente à sua inserção, receberam a aplicação de duas camadas do primer do sistema adesivo ScotchBond Multi Uso. Após o acabamento e polimento, as restaurações foram fotografadas, bem como aos 6 e 12 meses após suas realizações. Os dentes foram avaliados por 2 examinadores, quanto aos fatores retenção, adaptação marginal, descoloração marginal, alteração de cor, presença de lesão de cárie marginal, forma anatômica e sensibilidade na análise clínica; e na análise clínica/fotográfica quanto aos fatores retenção, descoloração marginal, localização da gengiva marginal, alteração de cor e forma anatômica da restauração. Os resultados foram submetidos ao teste de Kappa observando um grau de concordância acima de 80% entre os examinadores. A aplicação do Teste de Kruskal-Wallis não apontou diferença estatisticamente significante, na análise clínica, para as variáveis forma anatômica, descoloração marginal, alteração de cor, lesão de cárie, adaptação... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the performance of 124 restorations of non-carious cervical lesion through clinical and clinical/photographic analyses. The restorations were made in composite resin or resin-modified glass ionomer and evaluated after 6 and 12 months. Three groups were obtained according to the materials and techniques. Previously to the application of the adhesive materials, all teeth were submitted to acid etching with 37% phosphoric acid in enamel and dentine. Then, the teeth of group I received the conventional adhesive system Scotchbond Multi-Purpose followed by the composite resin Filtek Z350; the teeth of group II received only the resin-modified ionomeric material Fuji II L.C.; and the teeth of group III were restored with the same ionomeric material after application of two layers of the primer of the adhesive system Scotchbond Multi-Purpose. The restorations were photographed immediately after this procedure and after 6 and 12 months. The teeth were evaluated by 2 examiners regarding retention, marginal fit, marginal discoloration, color alteration, presence of marginal caries and sensitivity during the clinical evaluation. The clinical/photographic analysis evaluated retention, marginal discoloration, localization of the marginal gingiva, color alteration and anatomy of the restoration. The results were submitted to the Kappa test that revealed degree of agreement above 80% between the examiners. The Kruskal-Wallis test showed no statistically significant difference in the clinical analysis for anatomy, marginal discoloration, color alteration, caries, marginal fit and sensitivity among the three groups for each period of evaluation. However, there was statistically significant difference for retention at the 12-month follow-up considering that the group III was superior in comparison to the group II. The... (Complete abstract, click electronic address below) / Orientador: Renato Herman Sundfeld / Coorientador: Eduardo Passos Rocha / Banca: Marcelo Giannini / Banca: Rodrigo Sversut de Alexandre / Mestre
275

Influência da temperatura sobre a microdureza de uma resina composta fotoativada com luz halógena e Leds /

Cáceres Benítez, Pablino. January 2004 (has links)
Resumo: O objetivo desta pesquisa foi avaliar a influência de várias temperaturas sobre os valores de microdureza de topo e base de uma resina composta fotopolimerizável comercialmente disponível, variando o tipo de fonte de luz (LEDs e lâmpada halógena). As temperaturas testadas foram 25, 35, 45, 55, 65, 80, 90 e 100º C. A resina composta utilizada foi a Z100 (3M). Com o auxílio de uma matriz metálica foram confeccionados 3 corpos-de-prova de 2 mm de espessura e 9,8 mm de diâmetro para cada temperatura. Os corpos-de-prova foram polimerizadas LEDs (60 s) ou lâmpada halógena (40 s) enquanto eram submetidas às diferentes temperaturas, após a polimerização as amostras foram armazenadas a seco, em estufa a 37º C. Após 24 horas as amostras foram submetidas ao teste de microdureza Vickers no topo e na base. Baseados nos resultados conclui-se que com a elevação da temperatura aumentou o valor da dureza Vickers com correlação linear positiva e com ambos aparelhos; o valor da dureza de topo foi sempre superior à dureza de base independentemente da fonte de luz ou temperaturas empregadas; o aparelho de luz halógena só se mostrou superior à fonte de LEDs na região de base dos corpos-de-prova. / Abstract: The aim of this research was to evaluate the influence of several temperatures on the microhardness values of top and base of a light curing composites resin commercially available, varying the type of light source (LEDs and halogen lamp). The tested temperatures were 25, 35, 45, 55, 65, 80, 90 and 100º C. The composite resin used was Z100 (3M). With the aid of a metallic mould were made three samples of 2 mm of thickness and 9,8 m diameter for each temperature. The samples were light cure while they where submitted to the different temperatures with LEDs (60 s) and halogen lamp (40 s), after the polymerization the samples were dry stored in a stove at 37º C. After 24 hours, the samples were submitted to the Vickers microhardness test in the top and in the base. Based on the results it was concluded that with the elevation of the temperature increased the Vickers hardness value with positive linear correlation on both devices. The hardness value of the top was always superior to the base hardness, independently of the light source or used temperatures. The halogen lamp source was superior to the source of LEDs in the area of base of the samples. / Orientador: Osmir Batista de Oliveira Junior / Coorientador: Vanderlei Salvador Bagnato / Banca: Sizenando de Toledo Porto Neto / Banca: Marcelo Giannini / Mestre
276

Análise dos fotoiniciadores presentes em resinas compostas em função da cor /

Alvim, Hugo Henriques. January 2005 (has links)
Orientador: José Roberto Cury Saad / Banca: Rodrigo de Castro Albuquerque / Banca: Marcelo Ferrarezi de Andrade / Resumo: O objetivo deste estudo foi identificar e quantificar os fotoiniciadores utilizados em diferentes marcas comerciais de resinas compostas em função da cor analisada. Foram utilizadas as resinas compostas: Tetric Ceram A3 (TCA3); Tetric Ceram Translucent (TCT); Filtek Z250 A3 (FZA3); Filtek Z-250 Incisal (FZI); Pyramid Enamel A1 (PEA1); Piramyd Enamel Translucent (PET); Filtek Supreme A3E (FSA3) e Filtek Supreme GT (FSGT). Foram pesados 500mg de cada resina e dissolvidos em 1,0 ml de metanol. As amostras foram centrifugadas para acelerar a sedimentação das partículas inorgânicas. Foram pipetados 0,8 ml da solução sobrenadante que foi armazenada por 72 horas em estufa a 35º C para total evaporação do metanol. Após este período foi feita a ressuspensão com 0,5 ml de metanol e analisados por cromatografia líquida acoplado ao espectrômetro de massa (GC-MS). Os resultados foram comparados a soluções de canforoquinona pura, utilizada como padrão. O teste de T Student, significativo ao nível de 5%, comparou os resultados entre as cores de cada marca comercial. Observou-se menor quantidade de canforoquinona na cor incisal da resina Filtek Z-250 (FZI) quando comparada a cor A3 (FZA3). Por outro lado, as resinas Tetric Ceram e Filtek Supreme apresentaram quantidade de canforoquinona estatisticamente superior nas cores Incisais (TCT e FSGT). Na resina Pyramid Enamel foi encontrada canforoquinona apenas na cor A1 (PEA1), sendo que o fotoiniciador utilizado na cor Translucent não foi identificado. Baseado nos dados obtidos pode-se concluir que uma mesma marca comercial de resina composta pode apresentar diferenças na quantidade e no tipo de fotoiniciador utilizado. / Abstract: The aim of this study was to identify and quantify the photoinitiators used in different brands of composite resins in function of shade analyzed. It was used the following materials: Tetric Ceram A3 (TCA3); Tetric Ceram Translucent (TCT); Filtek Z250 A3 (FZA3); Filtek Z-250 Incisal (FZI); Pyramid Enamel A1 (PEA1); Piramyd Enamel Translucent (PET); Filtek Supreme A3E (FSA3) e Filtek Supreme GT (FSGT). A small portion (500 mg) of each composite resin was dissolved in 1,0 ml of methanol. The samples were centrifuged to accelerate the inorganic fillers sedimentation. An aliquot (0,8 ml) was stored in vials for 72 hours at 35º C for complete methanol evaporation. After this period was added 0,5 ml of methanol and the samples were analyzed by gas-liquid chromatograph associated to mass spectrometer (GC-MS). The results were compared to pure camphorquinone solutions, used as standart. The results between shades of each commercial brand were compared by T Student test significant at 5%. It was noticed statistical difference in the quantity of camphorquinone between the shades of all tested brands. In Pyramid Enamel was found camphorquinone only in the A1 shade (PEA1). The photoinitiator used in Translucent shade was not identified. Based upon the scientific data presented in this study, it was concluded that the same composite resin brand can present differences in the quantity and type of photoinitiator used. / Mestre
277

Influência de agentes clareadores na rugosidade de compósitos dentários / Influence of bleaching gels on roughness of dental composites

Eduardo Varanda 18 December 2009 (has links)
O clareamento dental é o meio disponível mais simples, comum e conservador para o cirurgião-dentista proporcionar aos pacientes o padrão de cor de seus dentes mais desejado. Em alguns casos, os dentes que vão ser clareados podem apresentar restaurações realizadas com compósitos dentais, que são mais suscetíveis a alterações químicas, quando comparados a outros materiais restauradores. Alguns estudos mostraram que diferentes concentrações de agentes clareadores levaram a um aumento significativo da rugosidade superficial e das porosidades em compósitos dentais. Este estudo avaliou o efeito de dois agentes clareadores (Whiteness HP Blue 20%, Whiteness HP Max) sobre a rugosidade superficial de dois compósitos dentais, um micro-híbrido (Esthet X, Denstply) e outro nanoparticulado (Z 350, 3M ESPE). Um total de oito corpos de prova (9 x 2 mm) foram confeccionados com auxílio de uma matriz de teflon, sendo divididos em 4 grupos (Esthet X + Whiteness HP Blue 20%; Esthet X + Whiteness HP Max; Z 350 + Whiteness HP Blue 20%; Z 350 + Whiteness HP Max), sendo n=2. Os corpos de prova foram armazenados em saliva artificial neutra e, após 24 horas, foram polidos com discos de óxido de Alumínio (Sof-lex, 3M ESPE). Após sete dias de imersão salivar, cada corpo de prova foi levado a um microscópio de força atômica para obtenção do valor inicial de rugosidade superficial (Ra em nm). Em seguida, sem remover o corpo de prova do microscópio, o agente clareador foi aplicado sobre a superfície do corpo de prova, segundo as instruções do fabricante, de modo que permitisse uma posterior observação da mesma área do corpo de prova observada inicialmente, para obtenção do valor final de rugosidade superficial. Imagens em duas e três dimensões foram obtidas de cada corpo de prova para observação de alterações da topografia. Os resultados foram tratados estatisticamente por ANOVA e pelo teste de contraste Student-Newman-Keuls (p < 0,05). Não houve alteração significativa na rugosidade superficial (Ra) dos corpos da prova de compósitos micro-híbrido e nanoparticulado, submetidos aos agentes clareadores Whiteness HP Blue 20% e Whiteness HP Maxx. No entanto, independente do agente clareador utilizado, foram observadas maiores alterações topográficas nas imagens de microscopia de força atômica da superfície do compósito micro-híbrido do que nas imagens do nanoparticulado. / Dental bleaching is the simplest, the most common and conservative available way for dentists to offer their patients the standard color of teeth more desired. In some cases, the teeth that will be bleached may include restorations made of resin composites, which are more prone to chemical alteration compared with other restoration materials. Some studies have showed that different concentrations of bleaching gels might lead to a significant increase in surface roughness and amount of porosities in composite resins. This study evaluated the effect of two bleaching gels (Whiteness HP Blue 20%, Whiteness HP Max) on surface roughness of two resin composites, micro-hybrid (Esthet X, Denstply) and nanoparticled (Z350, 3M ESPE). A total of eight specimens (9 x 2 mm) were produced with a Teflon mold help, and were divided into four groups (Esthet X + Whiteness HP Blue 20%; Esthet X + Whiteness HP Max; Z 350 + Whiteness HP Blue 20%; Z 350 + Whiteness HP Max), with n=2. They were stored in neutral artificial saliva and, after 24 hours, were polished with aluminium oxide discs (Sof-lex, 3M ESPE). After seven days of salivary immersion, each specimen was taken to an atomic force microscope for recording initial value of surface roughness (Ra in nm). After that procedure, without removing the specimen from microscope, the bleaching gel was applied on the surface of the specimen, following manufacturers instructions, in order to allow posterior observation of the same area of the specimen initially observed, for recording the final value of surface roughness. Two-dimensional and 3D images were taken from each specimen group for observation of surface alterations. The results were statistically analyzed by ANOVA and the SNK test (p< 0.05). There were no statistically significant differences in the surface roughness (Ra) for specimens of micro-hybrid and nanoparticled composites, submitted to the bleaching agents Whiteness HP Blue 20% and Whiteness HP Maxx. However, there were noticed larger surface alterations in atomic force microscope images on the surface of micro-hybrid composites than on the nanoparticled, independently of the bleaching agent used.
278

Efeito dos desafios erosivo ou erosivo/abrasivo sobre as estruturas dentárias adjacentes às restaurações realizadas com materiais contendo fluoreto ou cálcio / Effect of erosive and erosive/abrasive challenges on the dental hard tissues adjacent to restorations performed with materials containing fluoride or calcium

Ítallo Emídio Lira Viana 29 January 2018 (has links)
Esse estudo avaliou in vitro o efeito dos desafios erosivo ou erosivo/abrasivo sobre materiais restauradores contendo fluoreto ou cálcio e sobre as estruturas dentárias adjacentes às restaurações realizadas com esses materiais. Fragmentos de esmalte e de dentina bovinos (4 mm × 4 mm × 2 mm), foram incluídos em resina acrílica e planificados. Uma cavidade padrão com dimensões 1,2 mm × 4 mm × 1,5 mm foi preparada nos espécimes, e restaurada de acordo com o material a ser testado: 1. Z350 - resina composta (Filtek Z350, 3M ESPE); 2. VB - compósito experimental contendo apenas vidros de bário; 3. DCPD30% - compósito experimental contendo 10% de vidros de bário e 30% partículas de fosfato di-cálcio di-hidratado (DCPD) funcionalizadas com dimetacrilato de dietilenoglicol (DEGDMA); 4. DCPD60% - compósito experimental contendo 60% partículas de DCPD funcionalizadas com DEGDMA; 5. Beautifil - GIOMER (Beautifil II, Shofu Dental Corporation); 6. Fuji IX - cimento de ionômero de vidro convencional de alta viscosidade (Fuji IX, GC Corporation); 7. Fuji II LC - cimento de ionômero de vidro modificado por resina (Fuji II LC, GC Corporation). Na sequência, os espécimes foram polidos e submetidos a dois tipos de tratamentos: erosão somente (n=10) ou erosão mais abrasão por escovação (n=10). A erosão foi realizada pela imersão dos espécimes em ácido cítrico a 0,3% (pH~2,6) por 5 min, seguido de 60 min de imersão em saliva artificial. Esse procedimento foi repetido 4×/dia, por 5 dias. A escovação foi realizada com uma suspensão de dentifrício padrão (Colgate Total 12 Mint Clean; 1450 ppm F-, como NaF) por 15 s (2 min de exposição total a suspensão de dentifrício), 2×/dia, 30 min após o primeiro e o quarto desafios erosivos. Ao final da ciclagem, a perda superficial (em ?m) do esmalte, da dentina e dos materiais restauradores foi determinada com um perfilômetro ótico. Para cada modelo (erosão e erosão-abrasão), os dados de perda superficial de esmalte, dentina e restauração foram analisados de maneira independente. Os dados foram analisados pelos testes de Kruskal-Wallis e Tukey. O nível de significância utilizado foi de 5%. No modelo de erosão, para esmalte, ambos cimentos ionoméricos apresentaram menor perda superficial do que o compósito Z350, apesar de Fuji II LC não ter se diferenciado significativamente dos grupos Beautifil e DCPD30%. Os outros grupos não foram diferentes de Z350 nem entre si. Para dentina, nenhum dos grupos foi diferente de Z350, com exceção de DCPD60%, o qual apresentou a maior perda superficial. Ambos cimentos ionoméricos apresentaram menor perda do que DCPD30%, Beautifil e DCPD60%. Em relação à restauração, os materiais Z350, Beautifil, VB, DCPD30% apresentaram perda superficial mínima, sem diferenças entre eles. Os cimentos ionoméricos apresentaram os maiores valores de perda, não se diferenciando de DCPD60%. No modelo erosão-abrasão, para esmalte, a menor perda superficial foi observada em Fuji II LC, sem diferença da Beautifil. Os outros grupos não se diferenciaram entre si nem da Beautifil. Para dentina, os grupos DCPD60%, Beautifil, Fuji II LC, Z350 e Fuji IX não se diferenciaram e, apresentaram menor perda superficial do que VB. Os cinco grupos citados também não foram diferentes de DCPD30%, com exceção de Fuji IX. Em relação à restauração, a maior perda foi observada para Fuji IX, sem diferenças de Fuji II LC e Beautifil. DCPD30%, Z350, VB e DCPD60% apresentaram valores mínimos de perda superficial, sem diferenças entre si. Concluiu-se que o cimento ionomérico Fuji II LC foi único capaz de proteger o esmalte adjacente à restauração contra desafios erosivos e erosivos/abrasivos, apesar de ter sido um dos materiais mais susceptíveis ao desgaste por ambos desafios. Para dentina, nenhum material exibiu efeito protetor. / This in vitro study evaluated the effect of erosive or erosive/abrasive challenges on restorative materials containing fluoride and calcium, and on the dental hard tissues adjacent to restorations performed with these materials. Enamel and dentin specimens (4 mm × 4 mm × 2 mm), obtained from bovine incisors, were embedded in acrylic resin, flattened and polished. In the specimens, a standard cavity of 1,2 mm × 4 mm × 1,5 mm was prepared and restored with the following materials: 1. Z350 - Composite resin without actives, Filtek Z350 (3MESPE); 2. VB - experimental composite containing barium glass only; 3. DCPD30% - experimental composite containing 10% of barium glass and 30% of DCPD particles functionalized with DEGDMA; 4. DCPD60% - experimental composite containing 60% of DCPD particles functionalized with DEGDMA; 5. Beautifil - GIOMER (Beautifil II, Shofu Dental Corporation); 6. Fuji IX - high viscosity glass ionomer (Fuji IX, GC Corporation); 7. Fuji II LC - resin-modified glass ionomer (Fuji II LC, GC Corporation). The specimens were polished again and then submitted to one of the two treatments: erosion only (n=10) or erosion plus toothbrushing abrasion (n=10). Erosion was performed by immersing the specimens in 0.3% citric acid solution (p~2.6), for 5 min, followed by 60 min exposure to artificial saliva. This procedure was repeated 4 times a day, for 5 days. Toothbrushing was performed with a slurry of a standard dentifrice (Colgate Total 12 Mint Clean; 1450 ppm F, as NaF), for 15 s (2 min total exposure time to the slurry), 2 times a day, 30 min after the first and last erosive challenges. At the end of cycling, enamel, dentin and restorative material surface loss (in ?m) were determined by optical profilometry. Data were analyzed by the Kruskal-Wallis and Tukey tests. The level of significance was 5%. In the erosion model, for enamel, both ionomeric cements presented lower surface loss than the Z350, although Fuji II LC did not differ significantly from Beautifil and DCPD30% groups. The other groups were no different from Z350 and from each other. For dentin, none of the groups were different from Z350, except for DCPD60%, which presented the highest surface loss. Both ionomeric cements presented lower loss than DCPD30%, Beautifil and DCPD60%. Regarding the restoration, the materials Z350, Beautifil, VB, DCPD30% showed minimal surface loss, with no differences between them. The ionomeric cements had the highest loss values, not differing from DCPD60%. In the erosion-abrasion model, for enamel, the lowest loss was observed for Fuji II LC, with no difference to Beautifil. The other groups showed no difference among them and from Beautifil. For dentin, the groups DCPD60%, Beautifil, Fuji II LC, Z350 and Fuji IX were no significant different and presented lower loss than VB. These five groups were also no different from DCPD30%, except Fuji IX. Regarding the restoration, the highest loss was observed for Fuji IX, with no difference from Fuji II LC and Beautifil. DCPD30%, Z350, VB and DCPD60% presented minimum values of surface loss, without differences between them. It was concluded that Fuji II LC ionomeric cement was the only material able to protect the enamel adjacent to the restoration against erosive and erosive/abrasive challenges, although it was one of the materials that was most susceptible to be wear off by both challenges. For dentin, no material exhibited a significant protective effect.
279

Avaliação da resistencia de união de sistemas adesivos e cimentos resinosos a dentina e aos compositos restauradores / Evaluation of bond strength of adhesive systems and resincements to dentin and restorative composites

Garcia, Rubens Nazareno 26 May 2006 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T14:18:38Z (GMT). No. of bitstreams: 1 Garcia_RubensNazareno_D.pdf: 8662671 bytes, checksum: 0068fe648efbd833ec4737acd0f008f2 (MD5) Previous issue date: 2006 / Resumo: O atual conceito de união aos tecidos duros dentais é baseado na infiltração de sistemas adesivos em esmalte e dentina, no processo chamado de hibridização. Enquanto a união ao esmalte tem sido considerada um procedimento confiável devido a sua uniforme composição, a união à dentina continua sendo um desafio. O objetivo deste estudo foi avaliar e discutir os conceitos que envolvem os sistemas adesivos odontológicos e as técnicas de cimentação adesiva. O estudo compreendeu quatro avaliações que propuseram analisar: 1- a resistência de união (RU) de alguns sistemas autocondicionantes após uma semana e um ano de armazenamento em água; 2- a RU de cimentos resinosos aos compósitos utilizados na reconstrução dental; 3 e 4- a RU de técnicas de cimentação adesiva. Foram utilizados dentes bovinos nos experimentos 1, 2 e 3; e ensaios de microcisalhamento. Para o experimento 4 foram utilizados dentes humanos e o ensaio de microtração. Os resultados indicaram que: 1- entre todos adesivos testados, o adesivo autocondicionante One-Up Bond F não apresentou redução na RU após um ano; 2- a RU foi maior quando se aplicou adesivo hidrófobo entre o compósito restaurador e o cimento resinoso; 3 e 4- o uso de uma camada intermediária de resina de baixa viscosidade e fotoativação dos cimentos resinosos resultou em maiores valores de RU entre o cimento resinoso e a dentina. Os resultados sugerem que a união à dentina ainda é instável para a maioria dos sistemas adesivos; na união do cimento resinoso ao compósito restaurador, os adesivos hidrófobos são as melhores opções; e as técnicas de cimentação adesiva apresentam melhor desempenho com aplicação de uma camada intermediária de resina de baixa viscosidade e fotoativação do cimento resinoso / Abstract: The current concept of bonding to hard dental tissues is based on the infiltration of adhesive systems in enamel and dentin, in the so-called hybridization process. While the enamel bond has been considered a reliable procedure due to its uniform composition, bonding to dentin continues to present challenges. The objective of this study was to assess and discuss the concepts involving dental adhesive systems and the techniques of adhesive cementation. The study included four evaluations to determine: 1- the bond strength (BS) of some self-etching adhesive systems after one week and one year of storage in water; 2- The BS of the resin cements to composites used in dental restoration; 3 and 4- The BS of adhesive cementation techniques. Bovine teeth and micro-shear bond strength tests were used for experiments 1, 2 and 3. For experiment 4, human teeth and micro-tensile tests were used. The results indicated that: 1- among the adhesives tested, the self-etching adhesive One-Up Bond F did not show reduction in BS after one year; 2- the BS was higher when the hydrophobic bond was applied between the filling composite and the resin cement; 3 and 4- the use of an intermediary layer of low viscosity resins, and photoactivation of the resin cements, resulted in higher BS values between the resin cement and the dentin. The results suggest that bonding to dentin is still unstable for the majority of adhesive systems; in the union of the resin cement to the filling composite, hydrophobic adhesives are the best options; and the techniques of adhesive cementation present better performance with the application of an intermediate layer of low viscosity resin and photoactivation of resin cement / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
280

Profundidade de polimerização de cimentos resinosos : efeito de aparelhos fotoativadores e de materiais restauradores indiretos / In-depth polymerization of resin cements : effect of light curing units and indirect restorative materials

Tango, Rubens Nisie 04 March 2006 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T14:17:07Z (GMT). No. of bitstreams: 1 Tango_RubensNisie_D.pdf: 517454 bytes, checksum: 78bb278313f8acd3dca9e0eb5588eb01 (MD5) Previous issue date: 2006 / Resumo: Este estudo avaliou através do teste de dureza Knoop (KHN), a profundidade de polimerização do cimento resinoso Enforce, dual e fotoativado, quando fotoativados através da cerâmica (HeraCeram) ou do compósito (Artglass), com diferentes aparelhos fotoativadores. A fotoativação foi realizada com os aparelhos de luz de lâmpada halógena (XL2500) - QTH, luz emitida por diodos (Ultrablue 1s) - LED, ambos por 40 segundos, e aparelho de arco de plasma de xenônio (Apollo 95E) por 3 segundos - P AC. As faces vestibulares de incisivos bovinos foram planificadas e hibridizadas com o sistema adesivo Prime & Bond 2.1. Sobre estas superficies foi assentada uma matriz de borracha preta e opaca (lmm de espessura / 5mm de diâmetro), a qual foi preenchida com o cimento. Um disco de material para faceta (l,5mm de espessura) foi comprimido digitalmente sobre este conjunto para padronização da espessura de cimento e extravasamento dos excessos. A fotoativação foi realizada, com a ponta ativa dos aparelhos em contato com os illlteriais para faceta, sendo que nos grupos controle, a ativação foi realizada diretamente. Após armazenamento em ambiente seco e escuro (24h/37°C), as amostras (n=IO) foram seccionadas para mensuração dos valores de dureza (KHN), obtidos em aparelho microdurômetro (50gf de carga/ 15s). Os dados dos cimentos, dual e fotoativado, foram analisados separadamente. Para ambos, os dados foram submetidos à análise de variância de 3 fatores. Posteriormente, para o cimento dual foi aplicado o teste de Tukey e para o cimento fotoativado, o teste de Duncan (a=0,O5). Para ambos os cimentos, foram verificados que os valores de dureza diminuem com o aumento da profundidade de polimerização. Além disso, para ativação direta e através de HeraCeram, os maiores valores de dureza foram obtidos com LED, seguido por QTH e P AC. Para Artglass, no modo dual, valores de dureza similares foram obtidos com os 3 aparelhos fotoativadores. Já no modo foto ativado, os maiores valores foram obtidos com QTH, seguido pelo LED e P AC, respectivarrente. O aparelho P AC, com tempo de exposição de 3 segundos, mostrou-se ineficaz na polimerização do cimento no modo fotoativado através dos materiais para faceta. O efeito dos materiais para faceta foi distinto para cada aparelho foto ativador / Abstract: This study evaluated the polymerization depth of the dual-cure and light-cure resin cement Enforce, light-cured through ceramic (HeraCeram), or composite (Artglass), with different light curing units, by Knoop hardness (KHN) test. Light curing was carried out using conventional quartz tungsten halogen light (XL2500) - QTH, light emitting diodes (Ultrablue ls) - LED, both for 40s and, xemn plasma are (Apollo 95E) for 3s P AC. Bovine incisors had their buccal faces flattened and hybridized with the bond agent rime & Bond 2.1. On these surfaces, a black opaque mold (lmm thickness/ 5mm in diameter) was seated and filled with cement. A disc of the veneering material (l.5mm thickness) was compressed digitally over this set for cement thickness standardization and excesses remova!. Light curing was carried out with the light curing unit tip in contact with the veneering materiaIs. ln the control groups, resin cement was light cured directly. After dry storage at dark (24h/37°C), samples (n=lO) were sectioned for hardness (KHN) measurements, taken in a microhardness tester (50gf load/ 15s). Data of resin cement hardness, for dual cure and light cure, were analyzed separately. For both, data were submitted to three-way ANOV A. After that, Tukey's test was applied for dual cure resin cement, and for light cure cement Duncan's test was used (cx=.05). For both cements, it was verified that hardness decreased with the increase in polymerization depth. Besides that, for direct light curing and for light curing through HeraCeram, the highest hardness values were obtained with LED, followed by QTH and P AC. ln the dual cure resin cement beneath Artglass, similar hardness values were verified with the 3 light curing units. However, in light cure resin cement, the highest means were observed with QTH, followed by LED and PAC, respectively. PAC showed to be inefficient to polymerize the light cure resin cement beneath veneering materiaIs with 3s exposure time. The light transmission attenuating effect of veneering materiaIs was distinct for each light-curing unit / Doutorado / Materiais Dentarios / Mestre em Materiais Dentários

Page generated in 0.075 seconds