• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 285
  • 36
  • 8
  • 7
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 365
  • 365
  • 365
  • 365
  • 282
  • 279
  • 247
  • 246
  • 56
  • 54
  • 53
  • 49
  • 49
  • 46
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Estudo do risco de injúra ao canal mandibular em imagens de tomografia computadorizada por feixe cônico / Study of the injury risk to the mandibular canal bycone beam computed tomography images

Scomparin, Leandro 06 December 2013 (has links)
O conhecimento anatômico da mandíbula, do canal mandibular e outros reparos presentes na região mandibular são essenciais para o sucesso em vários procedimentos odontológicos, variando desde o mais básico como a anestesia, até procedimentos mais complexos, tais como a instalação de implantes, cirurgias ortognáticas e até mesmo cirurgias para correções estéticas de ângulo mandibular. O objetivo deste trabalho foi analisar as distâncias presentes da cortical vestibular mandibular, até a cortical vestibular do canal mandibular em 3 regiões específicas além da avaliação da região de fusão entre o córtex vestibular e lingual em exames de TCFC. Foram selecionadas 100 imagens de exames de TCFC pertencentes ao arquivo de imagens do Departamento de Estomatologia da Faculdade de Odontologia de Bauru. Para análise das medidas foi estudado o canal mandibular sendo investigadas as distâncias em pontos específicos que seriam de grande importância durante a realização de osteotomias em ramo e corpo mandibular, bem como a possibilidade de injúria neurosensorial. A distância da cortical vestibular do canal mandibular até a cortical vestibular da mandíbula foi de 2.95 mm na região da entrada do NAI na mandíbula, 3.88 mm na região de transição do ramo mandibular para corpo mandibular e 4,72 mm para a região mesial de segundos molares. A distância média da cortical lingual do canal mandibular até a cortical lingual da mandíbula foi de 2.07 mm na região de transição de ramo mandibular para corpo mandibular e 2.22 mm na região mesial de segundos molares. A distância da cortical do soalho do canal mandibular até a base mandibular foi correspondente a 8.54 mm na área de transição de ramo mandibular para corpo mandibular e de 6.97 mm na região mesial de segundos molares. A distância média da cortical do teto do canal mandibular até a cortical óssea superior da mandíbula na região de transição de ramo mandibular para corpo mandibular foi de 16.35 mm e de 16.08 mm para a zona corresponde à região mesial de segundos molares. No forame mandibular, local de entrada do NAI na mandíbula, a média obtida para o diâmetro do canal foi de 2.78 mm, enquanto que na região de transição entre ramo mandibular e corpo mandibular a média para o diâmetro do mesmo foi de 3.85 mm e na região mesial de segundo molar esta medida foi de 2.99 mm. Em 16% dos pacientes analisados havia algum tipo de variação anatômica presente no canal mandibular, fosse esta através de bifurcação ou trifurcação. A média de altura onde ocorre a fusão entre as placas cortical mandibular vestibular e lingual, acima do forame mandibular foi de 8,31mm e 8,48 mm para os exames realizados nos ramos mandibulares do lado esquerdo e direito respectivamente. Podemos concluir que os reparos anatômicos, assim como o conhecimento das medidas médias da anatomia do corpo humano são de grande valia durante a realização de procedimentos cirúrgicos, porém estes não podem e não devem ser utilizados de maneira aleatória pelo cirurgião, a individualidade e as variações anatômicas dos pacientes devem ser analisadas previamente ao planejamento cirúrgico, sendo que os materiais presentes no mercado para fixação interna não condizem com o esperado de acordo com a média anatômica do país encontrada em nosso estudo. / The anatomical knowledge of the jaw, the mandibular canal and other anatomical landmarks in the mandibular region are essential for success in various dental procedures, from anesthesia to implants insertions, orthognatic surgery and aesthetic corrections of mandibular angle.The aim of this paper was to locate the mandibular canal to the mandibular corticals canal in 3 specific regions and to evaluate union between the buccal and lingual cortical. We selected 100 CBCT exams of belonging to the image files of the Stomatology Department of the School of Dentistry in Bauru - Brazil.The distance of the mandibular canal cortical to the buccal plate of the mandible was 2.95 mm in the area of the entrance to the alveolar inferior nerve (AIN) into the mandibula, 3.88 mm in the transition region of the mandibular ramus to mandibular body and 4.72 mm for mesial region of second molars.The average distance of mandibular canal corticalto the lingual plate of mandible was 2.07 mm in the transition region of mandibular ramus to mandibular body and 2.22 mm in the mesial of second molars. The distance from the floor of the cortical mandibular base canal was corresponding to 8.54 mm in the area of transition of mandibular ramus to mandibular body and 6.97 mm in the mesial of second molars.The average distance from the ceiling of the cortical mandibular canal until the upper bone in mandibular cortical transition region of mandibular ramus for mandibular body was 16.35 mm and 16.08 mm for zone corresponds to the mesial area of second molars. In the mandibular foramen, place of entry of AIN in the mandibular the average obtained for the diameter of the canal was of 2.78 mm, while in the transition region between mandibular ramus and mandibular body the average for the same diameter was 3.85 mm and in the mesial of second molar this measure was 2.99 mm. In 13 of the patients surveyed had some sort of anatomical variation present in the mandibular canalwas this through bifurcation or trifurcation. The average height where the merger occurs between the cortical vestibular and lingual mandibular plates above the mandibular foramen was 8.31 mm and 8.48 mm for exams conducted in mandibular ramus on the left and right respectively. We can conclude that the repairs, as well as the anatomical knowledge of the average measures of anatomy of the human body are of great value during surgical procedures, but these cannot and should not be used randomly by the surgeon, individuality and anatomical variations of patients should be analyzed prior to surgical planning, moreover materials on the market for internal fixation are not consistent with the expected according to the anatomical national average found in our study.
262

Influência de artefatos metálicos produzidos pela presença de implantes de titânio na análise das cristas ósseas periodontais adjacentes, em tomografia computadorizada de feixe cônico / Assessment of the influence of metallic artefacts caused by dental titanium implants in cone beam computed tomography images at periodontal adjacent structures

Cremonini, Caio Cesar 01 June 2015 (has links)
Objetivo: Avaliação da influência de artefatos metálicos nas imagens de tomografia computadorizada de feixe cônico (TCFC), causados por implantes dentários, nas estruturas periodontais dos dentes adjacentes a esse implante. Materiais e Métodos: 23 pacientes foram submetidos ao exame de TCFC antes e após a colocação do implante dentário. Foram realizadas medidas da espessura das corticais vestibulares (CV) por um observador calibrado (ICC=0,95), nos cortes parassagitais de imagens previamente obtidas. Foi calculada a frequência de graus de influência do artefato metálico causado pelo implante (leve, moderado e severo) para distância horizontal ao implante, espessura da CV, e distância vertical em relação à crista óssea vestibular (COV). Resultados: excluídos 5 pacientes, em 18 selecionados, examinou-se 24 implantes unitários na região posterior de mandíbula, sendo 24 dentes teste mesiais (DTM) e 17 dentes teste distais (DTD) a esses implantes. Houve associação entre distância vertical da COV e impossibilidade de se mensurar a espessura da CV para o DTM e DTD (p<0,05 para ambos). Não houve associação entre espessura da cortical vestibular e distância horizontal para a severidade de influência de artefatos (p>0,05 para ambos). Houve associação entre distância horizontal e nível de influência de artefatos em quaisquer estruturas periodontais adjacentes ao implante, para DTM e DTD somados (p<0,05). Conclusão: Os artefatos metálicos causados por implantes dentários podem influenciar a interpretação da imagem de TCFC em sítios periodontais adjacentes, e o grau de influência depende da distância horizontal do implante dentário a quaisquer estruturas periodontais, e quanto mais próximo da COV, maior influência do artefato na identificação e mensuração de estruturas na CV. / Objective: The objective of this study was to evaluate the influence of metallic artifacts in CBCT (Cone beam computed tomography) images, caused by dental titanium implants, at adjacent periodontal structures. Materials and Methods: 23 patients were submitted a CBCT examination before and after the implant placement. Thickness Measurements of buccal cortical were performed by a calibrated observer (ICC=0.95), at parassagital cross-sections of previously obtained images. The frequency of influence level (mild, moderate, severe) of the artifact was calculated for horizontal distance of the implant, buccal cortical thickness and vertical distance of the buccal alveolar crest. Results: 5 patients were excluded, and 18 selected, 24 unitary implants cases at posterior mandible were examined, 24 mesial test teeth (MTT) and 17 Distal test teeth (DTT) from the implants. There was an association between the vertical distance of the buccal alveolar crest and the impossibility to measure the thickness of buccal cortical for MTT and DTT (p<0.05 for both). There was no association between the thickness of buccal cortical and horizontal distance for the artifacts level of influence (p>0.05 for both). There was association between horizontal distance and the level of the artifact influence at any periodontal structure, for the sum of MTT and DTT (p<0.05). Conclusion: the metallic artifacts caused by dental implants can influence the CBCT image interpretation at periodontal adjacent sites, and the level of the influence depends on the horizontal distance of the dental implant at any periodontal structures, and the vertical distance from the buccal alveolar crest.
263

Comparação entre ressonância magnética e tomografiacomputadorizada por feixe cônico para diagnóstico de regiões com enxertos em seios maxilares / Comparison between magnetic resonance imaging and cone beam computed tomography for the diagnosis of regions with grafts in the maxillary sinuses

Laurino, Fernando Antonio Reis 12 April 2019 (has links)
Uma das maneiras para corrigir a falta de volume ósseo em região posterior de maxila é o uso de enxertos ósseos para levantamento de assoalho de seio maxilar. O diagnóstico por imagem da região que recebeu o enxerto permite um planejamento cirúrgico preciso para a colocação de implantes dentários. Dentre os métodos descritos na literatura, a tomografia computadorizada por feixe cônico (TCFC), é uma técnica precisa para a obtenção de mensurações fiéis das dimensões do rebordo, e para avaliação da densidade mineral óssea (DMO). Recentemente, estudos têm demonstrado a técnica por imagem de ressonância magnética (RM) como uma técnica alternativa para avaliação da DMO também, além de apresentar a vantagem de não emitir radiação ionizante. No entanto, não existe um consenso na literatura sobre a diferença da precisão dos métodos descritos acima para diagnósticos clínicos de enxertos feitos em região de seio maxilar. Diante disso, o objetivo do presente estudo é comparar e correlacionar as medidas das dimensões obtidas de regiões enxertadas em seio maxilar de imagens de TCFC com as imagens de RM. / One of the ways to correct the lack of volume in a posterior plane of the jaw is the use of body grafts for lifting the maxillary sinus floor. Imaging of the region receiving the treatment allows for a precise surgical procedure for an association of dental implants. Among the methods in the literature, concomitant cone beam computed tomography (CBCT), is a precise technique for the application of resonance frequency measurements, and for the evaluation of bone mineral density (BMD). This study is a method for the evaluation of magnetic resonance imaging (MRI) in which an alternative technique for evaluation in the BMD also has an advantage of not emitting ionizing radiation. However, there is no consensus in the literature regarding the choice of the above schemes for clinical diagnoses of grafts made in the maxillary sinus region. Therefore, the present study is comparable and correlated with the images of grafted images in maxillary CBCT images with MRI images.
264

Diseño y puesta a punto de un método cefalométrico en 3D para el estudio de la población ortodóncica

Zamora Martínez, Natalia 07 July 2011 (has links)
Introducción: La introducción de la tomografía computarizada de haz cónico (CBCT) y su aplicación clínica a la imagen craneofacial tridimensional (3D) supone una herramienta diagnóstica esencial para el clínico. Objetivos: 1-Evaluar la reproducibilidad en la localización de puntos cefalométricos pertenecientes a tejidos duros del cráneo sobre imágenes escaneadas con un equipo CBCT 2-Comprobar si los valores de diferentes mediciones de las reconstrucciones 3D del CBCT se pueden comparar a las mediciones realizadas sobre imágenes 2D de la telerradiografía lateral de cráneo y comparar también si existen diferencias entre dos tipos diferentes de software de CBCT. 3-Diseñar un método cefalométrico 3D y determinar tres planos de referencia en cada uno de los ejes del espacio. Aplicar dicho análisis sobre una muestra de pacientes a los que se les ha realizado un CBCT. Material y Método: Se recogió una muestra global de 90 pacientes que tenían realizado un CBCT i-Cat®. 1-Para hallar la reproducibilidad, 15 CBCTs fueron seleccionados. Dos observadores localizaron 41 puntos en 3 ocasiones con el software NemoCeph 3D®. Se calcularon los Coeficientes de Correlación Intraclase (ICC) intra e interexaminador y se hallaron los errores de localización y asociados al método de medida de cada uno de los puntos. 2-Se seleccionaron 8 casos que tenían realizado además del CBCT, una telerradiografía lateral de cráneo convencional. Las telerradiografías se tomaron con el cefalostato Orthophos Plus DS® y se evaluaron con el software Dental Studio NX®, mientras que las reconstrucciones 3D (CBCT) se evaluaron con dos software diferentes, NemoCeph 3D® e InVivo5®. Un observador midió en dos ocasiones 10 medidas angulares y 3 lineales en cada uno de los registros, hallándose las correlaciones entre los tres tipos de métodos. 3-Se diseñó una cefalometría 3D y se empleó la muestra de los 90 CBCT para hallar los valores cefalométricos descriptivos de cada una de las variables creadas en cada una de las áreas de estudio: patrón facial, clase esquelética, relación maxilo-mandibular, medidas transversales, asimetrías, proporción facial y análisis dentoalveolar; mediante el cálculo de medias y desviaciones típicas, así como correlaciones de las diferentes variables entre sí y en función de la edad y del sexo. Resultados: 1-La reproducibilidad en la localización de los puntos cefalométricos para todos los ejes fue elevada (ICC ≥0.9) en las medidas intraobservador e interobservador. Analizando cada uno de los puntos por separado se encontró que el valor promedio de su desviación típica en todos los ejes fue igual a 1.0 mm. 2-No se encontraron diferencias estadísticamente significativas para ninguna de las medidas entre la telerradiografía lateral de cráneo y los CBCT, siendo los niveles de significación para todas las mediciones ICC>0.65. 3-Se ha creado un plano vertical de referencia (Na, S, Ba) así como diversos planos auxiliares y medidas lineales. Se han establecido las medias y desviaciones típicas de cada una de las variables del análisis 3D estudiadas, estableciendo así mismo diferentes correlaciones que nos sirven para la posterior creación de una base de datos. Conclusiones: 1-Se encontró elevada reproducibilidad en la localización de todos los puntos cefalométricos. Los puntos nasion, silla, basion, suturas frontocigomáticas, puntos anteriores de la rama, primer molar superior izquierdo e incisivo superior se pueden considerar como puntos altamente reproducibles para poder ser empleados en los análisis cefalométricos tridimensionales. 2-Es posible emplear la mayor parte de los valores establecidos en 2D para las mediciones 3D. Así mismo, las mediciones 3D no difieren entre NemoCeph 3D e InVivo5®, pudiéndose realizar las mediciones indistintamente en cualquiera de los dos software. 3-Se ha diseñado un método cefalométrico tridimensional dividido por áreas de interés que puede servir como punto de partida para la evaluación y medición de las características craneofaciales de todos aquellos pacientes que precisen como registro diagnóstico un CBCT. / Introduction: Cone Beam Computerized Tomography (CBCT) allows the possibility of modifying some of the diagnostic tools used in orthodontics, such as cephalometry. The aims were 1-To assess intra and inter-observer reliability in the location of anatomical landmarks belonging to hard tissues of the skull in images taken with a CBCT device, 2-To assess whether the values of different measurements taken on 3D reconstructions from CBCT are comparable with those taken on 2D images from conventional lateral cephalometric radiographs (LCR) 3-To introduce planes of reference and create a cephalometric analysis appropriated to the 3D reality. Study design: 90 patients who had a CBCT (i-Cat®) as a diagnostic register were selected. 1-To assess the reproducibility 15 CBCT were analysed. 41 landmarks were defined on the three spatial axes (X,Y,Z) and located by two observers at different times with the NemoCeph 3D® software. 2-To compare 13 measurements between LCR (Orthophos Plus DS®) and CBCT, 8 patients who had both registers were selected. Measurements were done with softwares Dental Studio NX® (LCR), NemoCeph 3D® (CBCT) e InVivo5® (CBCT). 3-To create and evaluate three spatial planes and a 3D analysis divided in different areas of interest, the 90 CBCT were selected. Results: 1- Intra- and inter-examiner reliability was high, both being ICC ≥ 0.99, with the best frequency on axis Z. 2- No statistically significant differences were found for the angular and linear measurements between the LCR and the CBCTs for any measurement being the correlation levels ICC<0.65. 3- Mean values, standard deviations and correlations of each one of the measurements defined on the 3D analysis were evaluated for all patients. Conclusions: 1-High reliability was found for all the landmarks. The most reliable ones were: Nasion, Sella, Basion, left Porion, point A, anterior nasal spine, Pogonion, Gnathion, Menton, frontozygomatic sutures, first lower molars and upper and lower incisors. 2-No statistically significant differences were found between measurements taken on the LCR and CBCT and in those taken between the two CBCTs. 3-A new 3D analysis has been created and can be applied to measure and evaluate those patients who require a CBCT as a diagnostic register.
265

Tomographie par rayons X : correction des artefacts liés à la chaîne d'acquisition

Wils, Patricia 17 November 2011 (has links) (PDF)
L'imagerie cone-beam computed tomography (CBCT) est une méthodologie de contrôle non destructif permettant l'obtention d'images volumiques d'un objet. Le système d'acquisition se compose d'un tube à rayons X et d'un détecteur plan numérique. La recherche développée dans ce manuscrit se déroule dans le contexte industriel. L'objet est placé sur une platine de rotation et une séquence d'images 2D est acquise. Un algorithme de reconstruction procure des données volumiques de l'atténuation de l'objet. Ces informations permettent de réaliser une étude métrologique et de valider ou non la conformité de la pièce imagée. La qualité de l'image 3D est dégradée par différents artefacts inhérents à la plateforme d'acquisition. L'objectif de cette thèse est de mettre au point une méthode de correction adaptée à une plateforme de micro-tomographie par rayons X d'objets manufacturés poly-matériaux. Le premier chapitre décrit les bases de la physique et de l'algorithmie propres à la technique d'imagerie CBCT par rayons X ainsi que les différents artefacts nuisant à la qualité de l'image finale. Le travail présenté ici se concentre sur deux types d'artefacts en particulier: les rayonnements secondaires issus de l'objet et du détecteur et le durcissement de faisceau. Le second chapitre présente un état de l'art des méthodes visant à corriger le rayonnement secondaire. Afin de quantifier le rayonnement secondaire, un outil de simulation basé sur des techniques de Monte Carlo hybride est développé. Il permet de caractériser le système d'acquisition installé au laboratoire de façon réaliste. Le troisième chapitre détaille la mise en place et la validation de cet outil. Les calculs Monte Carlo étant particulièrement prohibitifs en terme de temps de calcul, des techniques d'optimisation et d'accélération sont décrites. Le comportement du détecteur est étudié avec attention et il s'avère qu'une représentation 2D suffit pour modéliser le rayonnement secondaire. Le modèle de simulation permet une reproduction fidèle des projections acquises avec le système réel. Enfin, le dernier chapitre présente la méthodologie de correction que nous proposons. Une première reconstruction bruitée de l'objet imagé est segmentée afin d'obtenir un modèle voxélisé en densités et en matériaux. L'environnement de simulation fournit alors les projections associées à ce volume. Le volume est corrigé de façon itérative. Des résultats de correction d'images tomographiques expérimentales sont présentés dans le cas d'un objet mono-matériaux et d'un objet poly-matériaux. Notre routine de correction réduit les artefacts de cupping et améliore la description du volume reconstruit.
266

The production and detection of optimized low-Z linear accelerator target beams for image guidance in radiotherapy

Parsons, David, Parsons, David 22 August 2012 (has links)
Recent work has demonstrated improvement of image quality with low atomic number (Z) linear accelerator (linac) targets and energies as low as 3.5 MV compared to a standard 6 MV therapeutic beam. In this work, the incident electron beam energy has been lowered to energies between 1.90 and 2.35 MeV. The improvement of megavoltage planar image quality with the use of carbon and aluminum linac targets has been assessed compared to a standard 6 MV therapeutic beam. Common electronic portal imaging devices contain a 1.0 mm copper conversion plate to increase detection efficiency of a therapeutic megavoltage spectrum. When used in imaging with a photon beam generated with a low-Z target, the conversion plate attenuates a substantial proportion of photons in the diagnostic range, thereby reducing the achievable image quality. Image quality as a function of copper plate thickness has been assessed for planar imaging and cone beam computed tomography.
267

The validity, reliability and time requirement of study model analysis using cone-beam computed tomography generated virtual study models

Luu, Nghe S. Unknown Date
No description available.
268

Evaluation of dose and image quality parameters for cone-beam CT localization protocols in radiation therapy

Jacome, Victor Roland. January 2009 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaves 152-154.
269

Estudo da identificação humana por meio da imaginologia dos seios frontais.

Almeida, Manuella Santos Carneiro 13 March 2012 (has links)
Made available in DSpace on 2015-05-14T12:56:00Z (GMT). No. of bitstreams: 1 Arquivototal.pdf: 2176646 bytes, checksum: 1bc824e5cb69d2fcdee753f80f5eb8df (MD5) Previous issue date: 2012-03-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to verify the applicability of parameters for human identification using the frontal sinuses, used by Tatlisumak et al. (2007), using axial and coronal reconstructions of CBCT and extraoral radiographs. From 58 dry disjointed skulls existing in the Management of Legal Medicine of Paraiba (PB-GEMOL) and University Center of Joao Pessoa, UNIPÊ, 26 skulls were selected. The acquisition of anteroposterior radiographs of the skull and lateral view were obtained through X-ray machine pan Rotograph Plus ® (Dabi Atlante Ltda., Ribeirão Preto, São Paulo, Brazil) and the CT at New iCAT device Generation ® (Imaging Sciences International, Pennsylvania, USA), adopting a specific methodology in order to standardize the tests to obtain and ensure the reproducibility of the study. The images were evaluated by two examiners calibrated in darkened environment and in two different times, with a minimum interval of one week. Assessments of axial and coronal reconstructions were performed with the aid of a 23 "program and iCat Vision (Imaging Sciences International, Pennsylvania, USA). For evaluation of extraoral radiographs were traced on paper made using ultrafan of 600 lux light box with mask and measurements with the aid of a high precision digital caliper Mitutoyo series 167 (Mitutoyo, Suzano, Brazil). Categorical variables were discrete and analyzed using the kappa test and continuous variables by Correlation Coefficient of Concordance Lin. Methods of analysis by cone beam CT and radiographic were mostly consistent, with only a few variables with unsatisfactory results (capd, and dpele dpontalt). For categorical variables and discrete intra-and inter-was great-perfect for both methods, as continuous variables showed moderate to excellent results. It is concluded that: the methodology proposed in this paper, using the parameters of the job Tatlisumak et al. (2007), are applicable and reliable in extraoral radiographs (X-rays AP and lateral radiographs of the skull face) and axial and coronal reconstructions of CBCT for human identification by frontal sinus, intra-and inter the parameters used by Tatlisumak et al. (2007) with CBCT imaging modality varies from substantial to excellent, and moderate to excellent radiographic images, there is a greater power of reproducibility and accuracy of the proposed method using the axial and coronal reconstructions of CBCT taking extraoral radiographs also reliability , the least consistent variable in the analysis by the images of CBCT is a measure capd (poor agreement), while the radiographic images and are dpele dpontalt (bad matches). This result indicates that these parameters are more susceptible to errors by evaluators, since it needs to use multiple points of reference for their measurements. / O objetivo neste estudo foi verificar a aplicabilidade de parâmetros de identificação humana por meio dos seios frontais, utilizados por Tatlisumak et al. (2007), com auxílio das reconstruções axiais e coronais de tomografia computadorizada de feixe cônico (TCFC) e radiografias extrabucais. De um universo de 58 crânios secos desarticulados existentes na Gerência Executiva de Medicina e Odontologia Legal da Paraíba (GEMOL-PB) e Centro Universitário de João Pessoa, Unipê, foram selecionados 26 crânios. As aquisições das imagens radiográficas póstero-anterior de crânio e lateral de face, foram obtidas por meio do aparelho de raios X panorâmico Rotograph Plus® (Dabi Atlante Ltda., Riberão Preto, São Paulo, Brasil) e as tomográficas, pelo aparelho iCAT New Generation® (Imaging Sciences International, Pennsylvania, EUA), adotando-se uma metodologia específica como forma de padronizar a obtenção dos exames e garantir a reprodutibilidade do estudo. As imagens foram avaliadas por dois examinadores previamente calibrados, em ambiente escurecido e em dois tempos distintos, com um intervalo mínimo de uma semana. As avaliações das reconstruções axiais e coronais foram realizadas com o auxílio de um monitor de 23 e programa iCat Vision (Imaging Sciences International, Pennsylvania, EUA). Para avaliação das imagens radiográficas extrabucais, foram realizados traçados em papel ultrafan utilizando negatoscópio de 600 lux com máscara e as mensurações com auxílio de um paquímetro digital de alta precisão Mitutoyo série 167 (Mitutoyo Sul Americana, Suzano, Brasil). As variáveis categóricas e discretas foram analisadas por meio do teste kappa e as variáveis contínuas pelo Coeficiente de Correlação de Concordância de Lin. Os métodos de análise pelas tomografias de feixe cônico e radiográficas foram em sua maioria concordantes, apresentando apenas algumas variáveis com resultados insatisfatórios (capd, dpele e dpontalt). Para as variáveis categóricas e discretas houve concordância intra e interexaminadores de ótima a perfeita em ambos os métodos, já as variáveis contínuas apresentaram resultados de moderada a excelente. Conclui-se que: a metodologia proposta no presente trabalho, utilizando os parâmetros do trabalho de Tatlisumak et al. (2007), são aplicáveis e confiáveis em radiografias extrabucais (radiografias PA de crânio e radiografias laterais de face) e reconstruções axiais e coronais de TCFC para a identificação humana pelos seios frontais; a concordância intra e interexaminador nos parâmetros utilizados por Tatlisumak et al. (2007) com a modalidade de imagem TCFC varia de boa a excelente; e de moderada a excelente nas imagens radiográficas; há um maior poder de reprodutibilidade e precisão do método proposto utilizando as reconstruções axiais e coronais de TCFC, tendo as radiografias extrabucais também confiabilidade; a variável menos concordante na análise pelas imagens de TCFC é a medida capd (concordância ruim); já pelas imagens radiográficas são dpele e dpontalt (concordâncias ruins). Tal resultado indica que estes parâmetros são mais passíveis de erros por parte dos avaliadores, uma vez que deve-se utilizar vários pontos de referência para suas mensurações.
270

Avaliação tridimensional do côndilo mandibular em indivíduos pós-surto de crescimento pubertário após uso de Herbst bandado. / Three-dimensional evaluation of the mandibular condyle in individual post-pubertal growth outbreak after banded herbst use.

Almeida, Kélei Cristina de Mathias 17 March 2017 (has links)
Submitted by Kelei Cristina De Mathias Almeida (keleimathias.almeida@gmail.com) on 2018-09-05T16:47:11Z No. of bitstreams: 1 TESE Doutorado Kélei.pdf: 2128690 bytes, checksum: 6d32a1eacad944a350a690a474e3afa7 (MD5) / Rejected by Ana Cristina Jorge null (anacris@fclar.unesp.br), reason: Solicitamos que faça as seguintes correções: 1) O sumário deve conter todas as seções e subseções da sua tese (Ex. 2.1 Articulação temporomandibular (ATM) , 2.2.......e demais subseções); 2) As keywords devem ser as apresentadas no DECS. As suas palavras chaves em inglês no DECs são : Malocclusion, Angle class II Orthotic devices Cone-beam computed tomography Imaging, three-dimensional 3) Na ficha catalográfica o número correto de páginas é 108 f ; 4) Nos metadados você assinalou que não recebeu financiamento. Porém, na sua tese você agradece ao apoio financeiro da Capes e da Fapesp. Lembre-se que no caso da Fapesp é obrigatório informar também o número do processo; 5) Você não preencheu o nome do seu Programa de pós graduação no metadados; 6) Também não preencheu no metadados a área de concentração. Atenciosamente on 2018-09-05T18:58:25Z (GMT) / Submitted by Kelei Cristina De Mathias Almeida (keleimathias.almeida@gmail.com) on 2018-09-12T02:42:13Z No. of bitstreams: 1 TESE Doutorado Kélei Almeida.pdf: 2132229 bytes, checksum: f4f99b7fff170f591582b5ec78cec062 (MD5) / Approved for entry into archive by Ana Cristina Jorge null (anacris@fclar.unesp.br) on 2018-09-12T13:08:39Z (GMT) No. of bitstreams: 1 almeida_kcm_dr_arafo_int.pdf: 2132229 bytes, checksum: f4f99b7fff170f591582b5ec78cec062 (MD5) / Made available in DSpace on 2018-09-12T13:08:39Z (GMT). No. of bitstreams: 1 almeida_kcm_dr_arafo_int.pdf: 2132229 bytes, checksum: f4f99b7fff170f591582b5ec78cec062 (MD5) Previous issue date: 2017-03-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo prospectivo foi avaliar tridimensionalmente a remodelação e o deslocamento do côndilo mandibular na fossa articular nos indivíduos, pós-surto de crescimento pubertário, tratados com aparelho Herbst bandado. A amostra foi constituída por 24 indivíduos, de ambos os gêneros, leucodermas, com idade cronológica média de 16 anos e 1 mês. Os indivíduos foram tratados com aparelho Herbst bandado por um período de 8 meses (média da amostra: 9,8 meses). Para a avaliação da remodelação do côndilo mandibular foram utilizadas tomografias computadorizadas de feixe cônico (TCFC) em dois tempos, denominados de T1 (antes da colocação do aparelho e T2 (após a remoção do mesmo). As tomografias foram obtidas pelo tomógrafo i-CAT Classic e os dados foram exportados no formato DICOM (Digital Image and Comunication in Medicine) e avaliados no programa Dolphin® Imaging 11.5 Premium. As medidas foram analisadas nas imagens dos cortes multiplanares (planos coronal, sagital e axial) por um observador, previamente calibrado. Os dados obtidos foram calculados pelo sistema de coordenadas cartesianas tridimensionais em um programa de software Matlab desenvolvido pelo Departamento de Física e Biofísica, da Faculdade Estadual Paulista – UNESP de Botucatu. Para avaliar o grau de concordância entre as mensurações empregouse o coeficiente de correlação intraclasse (ICC). À exceção das medidas FOE (eixo Z), C1E (no eixo X) e C2-T2 em ambos os lados, todas as demais medidas apresentaram alto grau de reprodutibilidade, denotando que o erro do método pode ser desprezado. O deslocamento dos côndilos, no sistema de coordenadas cartesianas, foi calculado com o Ponto Zero na Base do crânio; a remodelação foi calculada com o Ponto Zero na média da distância dos forames mentuais direito e esquerdo, forneceu uma análise quantitativa e qualitativa e distâncias euclidianas. Com relação a base do crânio, o côndilo direito se deslocou de forma moderada (0,71mm) para baixo e de forma relevante (0,91mm) para frente; o côndilo esquerdo se deslocou de forma relevante (0,93mm) para baixo e de forma moderada (0,73mm) para frente. O côndilo direito remodelou de forma relevante 1,08mm para trás e se distanciou da média da distância dos forames mentuais de forma relevante (1,19mm); o côndilo esquerdo remodelou de forma relevante 0,98mm para cima e se distanciou da média da distância dos forames mentuais de forma relevante (0,93mm). Foram mensurados os espaçamentos entre os pontos nos côndilos direito e esquerdo, em relação a fossa articular, sendo observado aumento de forma média, do espaçamento superior do côndilo esquerdo (0,34mm). O tratamento não promoveu alterações significantes nas medidas no eixo X, constatando que não houve movimento de lateralidade. Conclui-se que, com relação a base do crânio, os côndilos direito e esquerdo se deslocaram para baixo e para frente. O côndilo direito remodelou para trás enquanto que o côndilo esquerdo remodelou para cima. / The aim of this prospective study was to evaluate in 3-D the remodeling and displacement of the mandibular condyle in the glenoid fossa in the individuals, post-pubertal growth outbreak, treated with the banded Herbst appliance. The sample consisted of 24 individuals of both genders, leucoderma, with a mean chronological age of 16 years and 1 month. Subjects were treated with banded Herbst appliance during 8 months. Cone beam computed tomography (CBCT) was performed in two times to evaluate the condylar remodeling: T1 (prior to placement of the device) and T2 (after removal).) CT scans were obtained by i-CAT tomography Classic and the data were exported in DICOM (Digital Image and Communication in Medicine) format and evaluated in the Dolphin® Imaging 11.5 Premium program. The measurements were analyzed in multiplanar sections images (coronal, sagittal and axial planes) by an observer, previously calibrated. The data obtained were calculated by 3-D Cartesian coordinate system in a Matlab software, developed by the Department of Physics and Biophysics, UNESP Botucatu. To evaluate the agreement degree between the measurements, the intraclass correlation coefficient (ICC) was used. With the exception of the measurements FOE (Z axis), C1E (X axis) and C2-T2 on both sides, all other measurements showed a high degree of reproducibility, denoting that the error of the method can be neglected. The displacement of the condyles in the Cartesian coordinate system was calculated with the Zero Point in the skull base; the remodeling was calculated with the Point Zero in the mean distance of the right and left mental foramina, provided a quantitative and qualitative analysis and Euclidean distances. In relation to skull base, the right condyle moved moderately (0.71 mm) downwards and significantly (0.91 mm) forward; the left condyle shifted significantly (0.93mm) downwards and moderately (0.73mm) forward. The right condyle significantly remodeled 1.08mm behind and distanced itself from the mean distance of the mental foramina significantly (1.19mm); the left condyle significantly reshaped 0.98mm upward and distanced itself from the mean distance of the mental foramina significantly (0.93mm). The spacing between the points on the right and left condyles were measured, in relation to the glenoid fossa; there was a mean increase in the superior space of the left condyle (0.34 mm). The treatment did not promote significant changes in the measurements on the X axis, noting that there was no laterality movement. It was concluded that, with respect to the skull base, the right and left condyles moved downwards and forward. The right condyle remodeled backwards while the left condyle remodeled upward. / 2010/17934-8

Page generated in 0.0871 seconds