• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 490
  • 9
  • 1
  • 1
  • Tagged with
  • 506
  • 506
  • 314
  • 297
  • 61
  • 50
  • 47
  • 47
  • 47
  • 46
  • 45
  • 43
  • 42
  • 41
  • 40
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Caracterização otica em materiais transparentes e sua relação com o confortoambiental em edificação

Assis, Rosana Maria Caram de 01 July 1998 (has links)
Orientador: Lucila Chebel Labaki / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-23T22:30:09Z (GMT). No. of bitstreams: 1 Assis_RosanaMariaCaramde_D.pdf: 6723016 bytes, checksum: 500021213eaaf3544e5bca1bbaa70192 (MD5) Previous issue date: 1998 / Resumo: Neste trabalho é realizada a caracterização e análise da transmissão da radiação solar através de materiais transparentes empregados em fachadas de edificações. São estudados os vidros refletivos metalizados a vácuo, os policarbonatos e as películas de controle solar, utilizadas sobre o vidro comum. O vidro eletrocrômico, material em desenvolvimento e promissor, também é analisado.Discute-se o comportamento ótico destes materiais nos diferentes intervalos do espectro solar ultravioleta, visível e infravermelho, e seu desempenho do ponto de vista do conforto no ambiente construído. O estudo utiliza a técnica da espectrofotometria para a análise da transmissão espectral dos materiais. Os resultados mostram que os vidros refletivos metalizados a vácuo e o vidro eletrocrômico no estado polarizado apresentam baixa transparência ao infravermelho, e em alguns casos, também para a luz visível. Os policarbonatos são bastante transparentes a toda a região do espectro solar, com exceção da região ultravioleta, à qual são opacos. As películas de controle solar não refletivas mostram-se bastante transparentes ao infravermelho, e pouco à luz visível. Já as refletivas transmitem pouco nas duas regiões. Ambas são praticamente opacas ao ultravioleta. Os resultados fornecem subsídios e indicativos para o emprego apropriado de superfícies transparentes quando de sua especificação, além de complementar informações técnicas pouco disponíveis no mercado / Abstract: In this work, the characterization and analysis of the solar radiation transmission through transparent materials appropriated for buildings façades is presented. Materials such as reflective sputtered glasses, polycarbonates and commercial polymeric films for solar control on float glass are studied. The electrocromic glass type, promissory new material under development, is also analyzed. The optical behavior of such materials in the different ranges of the solar spectrum: ultraviolet, visible and the infrared, and their performance concerning thermal comfort are compared and discussed. The analysis of spectral transmission by these materials is carried out through spectrophotometric technique. The results show that both reflective sputtered glasses and polarized electrocromic device present low transparence to infrared, and under some conditions, are transparent to the visible light, as well. The polycarbonates present high transparence over all solar spectrum ranges, with the exception of the ultraviolet region, to which they are opaque. Non-reflective solar control films are highly transparent to infrared radiation and a few to the visible light. Reflective glasses present low transmission in these regions. Both kinds of films are however practically opaque to ultraviolet radiation. The results provide specifications and indicatives for the appropriated uses of transparent surfaces in buildings, enriching the few amount of technical data ordinary available to professionals / Doutorado / Saneamento e Ambiente / Doutor em Engenharia Civil
62

Conforto e "stress" termico em industrias : pesquisas efetuadas nas regiões de Joinville, SC e Campinas, SP

Hackenberg, Ana Mirthes 15 May 2000 (has links)
Orientador: Jose Tomaz Vieira Pereira / Tese (doutorado) - Universidade Estadual de Campinas. Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-27T05:18:00Z (GMT). No. of bitstreams: 1 Hackenberg_AnaMirthes_D.pdf: 28706243 bytes, checksum: 75da923dcca548963a0d5cc4f20526fd (MD5) Previous issue date: 2000 / Resumo: O presente trabalho apresenta uma avaliação de algumas normas ISO de conforto e stress térmico em ambientes fabris no clima sub-tropical. Estas normas tiveram origem em trabalhos de pesquisa desenvolvidos em climas mos no hemisfério norte. Estudos recentes em climas tropicais, na Ásia, na Austrália e no Brasil contestam alguns limites de conforto térmico indicados nestas normas, afirmando que são adequados para climas mos, devendo ser um pouco mais altos para climas quentes. O trabalho teve como objetivo avaliar a sensação térmica dos trabalhadores industriais em duas regiões com climas diferentes e edificações com características construtivas e sistemas de controle térmico também diferentes. A metodologia adotada foi a proposta pela ISO, com medições dos parâmetros ambientais complementado com a realização de pesquisa entre os usuários, contendo questões sobre sensação térmica, características pessoais, atividade exerci da e vestimenta utilizada. Foram avaliadas as influências ambientais, atividade e vestimenta nas respostas dos trabalhadores e a aplicabilidade do questionário da ISO 10551 para diferentes culturas em que foi originado / Abstract: The present work presents an evaluation of the use of some norms cornfort ISO and thermal stress in industrial atmospheres in the sub-tropical climate. These norms had origin in research works developed in cold climates in Northem Hemisphere. Recent studies in tropical climates, in Asia, in Australia and in Brazil they answer some limits of thermal comfort indicated in these norms, affirming that they are appropriate for cold climates, should be a little higher for hot climates. The work had as objective evaluates the industrial workers' thermal sensation in two areas with different climates and constructions with constructive characteristics and systems of thermal control also different. The adopted methodology was the proposal for ISO, with measurements of the environrnental parameters complemented with the research accomplishment among the users, containing subjects about thermal sensation, personal characteristics, exercised activity and used vestiment. They were appraised the environrnental influences, activity and vestiment in the workers' answers and the aplicabilidade of the questionnaire of ISO 10551 for different cultures in that was originated. / Doutorado / Doutor em Planejamento de Sistemas Energéticos
63

Climatologia e previsão climatológica, via modelo RegCM3, de índices de conforto térmico para a região metropolitana de São Paulo / Climatology and climatological forecasting of thermal comfort indexes by RegCM3 model for the metropolitan region of São Paulo.

Batista, Rafael Jonas Righi 22 October 2012 (has links)
Como o tempo e o clima influenciam o homem e a sociedade são alvos de estudo desde que Hipócrates, 400 a.C., escreveu \"Ares, águas e lugares\". A partir do século XX, desenvolveram-se índices de conforto térmico (CT) que, apesar de apresentarem limitações, mostraram-se capazes de quantificar essas interações através de uma aplicação maleável e acessível. Observa-se que apesar de parte dos estudos biometeorológicos abordarem as mudanças climáticas, poucos tratam da projeção de índices para cenários futuros. Assim, o objetivo geral desse trabalho foi avaliar o comportamento climatológico do Índice de Desconforto (ID), Temperatura Resultante (TR) e Temperatura Resultante com o vento (TRv) na Região Metropolitana de São Paulo (RMSP) e projetá-los para o futuro, através das simulações do modelo regional climático (MCR) RegCM3, para os anos de 1960 a 1990, 2010 a 2040 e 2070 a 2100. O MCR foi forçado pelo Modelo de Circulação Geral da Atmosfera (MCGA) ECHAM5, de acordo com o cenário de emissões A1B, estabelecido pelo Painel Intergovernamental de Mudanças Climáticas (IPCC). Assim, é realizada uma avaliação dos meses de maior desconforto na RMSP com base nos dados da estação meteorológica do IAG através dos quantis. Maior foco é dado nos quantis superiores e inferiores (QS e QI) que representam as situações de maior desconforto e exercem influência em populações vulneráveis, como a dos idosos. A Raíz Quadrada do Erro Médio elevado ao Quadrado (RMSE) e o Erro Médio (EM, viés) das séries de dados, simuladas e observadas, demonstram uma subestimativa da temperatura para todo o ano, por parte do modelo. Já o RMSE e EM, da umidade relativa e vento, variam de acordo com a época do ano, possuindo períodos de maior e menor precisão. A título comparativo, também foram obtidos o RMSE e EM dos índices de conforto térmico simulados e observados. No período de 1960-1990, ID passa de 17,4°C para 20,1°C em 2070-2100, representando um aumento de 2,8°C; enquanto que TRv vai de 11,8°C para 14,7°C no mesmo período, tendo aumento de 2,9°C. Nota-se que o aumento de ID ocorre de forma gradativa com o passar dos anos, diferentemente de TRv, que aumenta de forma significativa a partir de 2070. Observa-se também que as médias diárias de ID e TRv tendem a se distribuir em quantis intermediários e superiores, indicando que ao longo dos anos, a RMSP tende a ter noites e tardes mais quentes, traduzindo em invernos menos desconfortáveis (em relação ao frio) e verões mais desconfortáveis (em relação ao calor). Os resultados obtidos corroboram IPCC (2007b), que também aponta para uma redução dos dias frios em regiões de médias e baixas latitudes, associado a um aumento na ocorrência de ondas de calor, de forma a oferecer grandes riscos à populações vulneráveis. / How weather and climate influence man and society, are main targets since Hippocrates wrote \"Airs, waters and places\", 400 BC. Thermal comfort indices, in development since the twentieth century, are able to quantify these interactions by flexible and accessible applications, despite their own limitations. Although part of the biometeorological studies address climate change, only few deals with future scenarios. Therefore, the main objective is to evaluate the climatological behavior of thermal comfort indices, such as the Discomfort Index (ID), Resultant Temperature (TR) and the Resultant Temperature with the wind (TRv) in the Metropolitan Region of São Paulo (MRSP). Climatological behavior is analyzed for three time slices (1960 to 1990, 2010 to 2040 and 2070 to 2100) through the Regional Climate Model (RCM) RegCM3. The RCM is forced by General Circulation Model (GCM) ECHAM5, according to the A1B emissions scenario, established by the Intergovernmental Panel on Climate Change (IPCC). More attention is given to the superior and inferior quantiles (QS and QI) representing the situations of greater thermal discomfort because of their influence on vulnerable populations such as elderly people. An initial assessment about the months of greatest discomfort in MRSP was made based on data from the meteorological station of IAG. The Root Mean Square Error (RMSE) and the Mean Error (EM, related to bias) of the time series from observed and simulated data show a models underestimation of the temperature throughout the year. The RMSE and EM for relative humidity and wind vary with the season containing periods of higher and lower accuracy. The RMSE and EM for simulated and observed indices were obtained as well due to comparison reasons. In 1960-1990 period, ID presents an average of 17.4°C and in 2070-2100, an average of 20.1°C, representing an increasing of 2.8°C; meanwhile TRv goes from 11.8°C to 14.7°C over the same period, an increasing of 2.9°C. It is show that ID is increased gradually over the years, unlike TRV, which significantly increases from 2070. It is also observed that daily means of ID and TRv in future tends to be distributed in middle and upper quantiles, indicating that the MRSP tends to have nights and afternoons that will be warmer over the years, translating into less uncomfortable winters (cold related) and more uncomfortable summers (heat related). The results corroborate IPCC (2007b) which also points to a reduction of cold days in regions of middle and low latitudes, associated with an increased occurrence of heat waves providing great risks to vulnerable populations.
64

Síntese de xerogel para fins de conforto térmico em placas cerâmicas

Avrella, Grégori 29 October 2015 (has links)
Submitted by Cátia Araújo (catia.araujo@unipampa.edu.br) on 2017-01-26T11:34:08Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Síntese de xerogel para fins de conforto térmico em placas cerâmicas.pdf: 3988842 bytes, checksum: 321e3abf353287e58a51e951e02f702a (MD5) / Approved for entry into archive by Cátia Araújo (catia.araujo@unipampa.edu.br) on 2017-01-26T11:35:12Z (GMT) No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Síntese de xerogel para fins de conforto térmico em placas cerâmicas.pdf: 3988842 bytes, checksum: 321e3abf353287e58a51e951e02f702a (MD5) / Made available in DSpace on 2017-01-26T11:35:12Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Síntese de xerogel para fins de conforto térmico em placas cerâmicas.pdf: 3988842 bytes, checksum: 321e3abf353287e58a51e951e02f702a (MD5) Previous issue date: 2015-10-29 / A sintese de um material xerogel foi feita através do método sol-gel de síntese por reações de hidrólise e condensação utilizando tetraetilortosilicato (TEOS) e trimetilclorosilano (TMCS) como materiais precursores em uma solução hidroalcoólica contendo etanol e água bidestilada. Hexametil-bis-siloxano, trimetilmetoxi- siloxano e trietoxi-trimetil-bis-siloxano foram identificados como os principais componentes na mistura sintetizada do material xerogel. Estes materiais quando inseridos a 8% (p/p) em uma Argila Vermelha extraída da região centro-oeste do estado do Rio Grande do Sul providência um aumento na resistência térmica de placas cerâmica em escala reduzida. Medidas de condutividade térmica foram feitas através do método do fio quente paralelo (DIN-EN-993-15) e mostraram uma redução de cerca de metade da condutividade térmica de 0,6549 W/mK (placas cerâmicas em escala reduzida contendo somente Argila Vermelha) para 0,2850 W/mK (placas cerâmicas em escala reduzida contendo 8% de uma mistura de xerogéis). Este fato é atribuído ao aumento no número de vazios na estrutura das placas cerâmicas pela presença de 8% (p/p) da mistura de xerogéis sintetizados conforme revelam os dados diminuição da densidade de 1,75±0,02 g/cm³ para 1,72±0,02 g/cm³. / The production of the xerogel material was made through the sol-gel synthesis method by the hydrolysis and condensation reactions using the tetraethylortosilicate (TEOS) and trimethylchlorosilane as the precursors materials in a hydroalcoholic solution containing ethanol and bi-distilled water. Hexamethyl-bis-siloxane, trimethylmethoxy- siloxane and Triethoxy-trimethyl-bis-siloxane were identified as main components presents in the mixture of synthetized xerogel material. These materials when inserted at 8% (w/w) in a red clay extracted near to west-south region of Rio Grande do Sul state from Brazil provides an increase in thermal resistance on ceramic plates in reduced scale. Measurements of thermal conductivity was made by parallel hot wire method (DIN-EN-993-15) shows a reduction by around half of thermal conductivity from 0,5354 W/mK (ceramic plates in reduced scale containing only red clay) for 0,2850 W/mK (ceramic plates in reduced scale containing 8% of mixture of xerogel). This feature was attributed to increases on voids number on ceramic plates structure by presence of 8% (w/w) of the mixture of xerogels synthetized according revel the decreases of density from 1,75±0,02 g/cm³ to 1,72±0,02 g/cm³.
65

Bem-estar de matrizes suínas em gestação: Estimativa da condição de conforto térmico, análise comportamental e produtiva no alojamento coletivo com uso de cama / Welfare of gestating sows: an estimate of thermal comfort conditions, behavioral and productive analysis in group housing with the use of bedding

Nunes, Maria Luisa Appendino 16 January 2012 (has links)
A discussão do bem-estar de matrizes suínas gestantes é um tema em destaque em função do uso de gaiolas individuais. Assim, é urgente a geração de conhecimentos voltados ao alojamento coletivo. Objetivou-se com esta pesquisa avaliar aspectos produtivos, comportamentais, fisiológicos e bioclimáticos resultantes do uso de cama na fase de gestação suína, em diferentes sistemas de alojamento. O experimento foi realizado no Município de Itu/SP, entre os meses de janeiro e setembro de 2010, durante 2 ciclos de gestação (experimentos 1 e 2). Em cada ciclo foram alojadas 216 porcas gestantes em quatro tratamentos de forma a avaliar: tipo de alojamento (combinado - GB ou coletivo B) e tipo de piso (cama de maravalha - CC ou concreto - SC). No capítulo 3 foram avaliadas características físicas do ambiente e indicadores fisiológicos de conforto térmico. No capítulo 4 foram avaliados os padrões comportamentais nos tratamentos, bem como resultados reprodutivos. Foram verificadas piores condições microclimáticas em cama (P<0,05), com aumento da temperatura e entalpia específica do ar (1,14 ºC e 2,37 kJ/kg ar seco, respectivamente). No experimento 2, ocorreu interação (P<0,05) entre horário e presença de cama, de forma que somente nos horários da manhã e meio dia a presença de cama implicou em aumento da temperatura e entalpia específica do ar. No experimento 1, a temperatura do piso na área suja apresentou-se maior em cama, com um aumento de 2,61 ºC (P<0,05). O mesmo ocorreu no experimento 2, no entanto, com interação entre temperatura do piso na área suja e horário. Em geral, a temperatura do piso na área limpa apresentou-se maior nos sistemas SC. No experimento 1 a temperatura retal não diferiu significativamente (P>0,05), diferentemente do experimento 2 no qual foi observado aumento significativo na presença cama. Em ambos os experimentos, a temperatura da pele e frequência respiratória apresentaram-se maiores em cama. Fêmeas mantidas em cama tiveram maiores frequências na postura em pé (20,9 e 31,4% para GBSC e GBCC e 20,6 e 39,2% para BSC e BCC, respectivamente). Foram encontradas evidências de que a cama diminui a ocorrência de estereotipias orais e lesões corporais. Os modelos desenvolvidos mostraram que a maioria das variáveis reprodutivas não foi afetada pelos tratamentos. O uso de cama alterou negativamente aspectos bioclimáticos do sistema, expresso na maior entalpia específica do ar, com as variáveis fisiológicas indicando maior estresse por calor. Por outro lado, a avaliação comportamental e de lesões indicou vantagens relacionadas ao uso de cama. A similaridade dos resultados produtivos obtidos mostra que o uso de cama e o alojamento em grupo durante toda a gestação devem ser considerados, no entanto, devem ser estudadas formas de climatização do ambiente produtivo para permitir bemestar térmico, associado a outros quesitos do bem-estar animal. / The increased concern about animal welfare in the world is evident. In this area, the housing system of gestating sows is especially significant due to the use of individual cages. Thus, the generation of knowledge of group housing is urgent. Information on the use of bedding for these animals in the Brazilian climate is scarce. The purpose of this research was to evaluate productive, behavioral, physiological and bioclimatic aspects resulting from the use of bedding in the gestation period of sows, in different housing systems. The experiments were conducted in Itu, state of São Paulo, between January and September 2010, during two gestation periods (experiments 1 and 2). In each period 216 gestating sows were housed in four treatments, in order to evaluate the type of housing CP or P (cage and pen - CP or en - P) and the type of floor WB or NB (wood shaving bedding/with bedding WB or concrete/no bedding - NB). In Chapter 3 we analyzed the physical characteristics of the environment and the physiological indicators of thermal comfort. In chapter 4 we evaluated the behavioral patterns in the treatments, as well as the reproductive results. Worse microclimatic conditions were observed in the bedding (P<0.05), with increase in temperature and in specific enthalpy of air (1.14 ºC and 2.37 kJ/kg dry air, respectively). In experiment 2 there was interaction (P<0.05) between the time and the presence of bedding. Only in the morning and at noon the presence of bedding caused increase in temperature and in specific enthalpy of air. In experiment 1, the floor temperature in the dirty area was higher with the use of bedding, with an increase of 2.61 ºC (P<0.05). The same occurred in experiment 2, but there was interaction between floor temperature in the dirty area and the time. In general, the floor temperature in the clean area was higher in the NB systems. In experiment 1, the rectal temperature did not differ significantly in the treatments (P<0.05), whereas experiment 2 showed higher rectal temperature in the presence of bedding. In both experiments, skin temperature and respiratory rate were higher in the bedding. Sows kept in the bedding system had higher rates of standing posture (20.9 and 31.4% for CPNB and CPWB and 20.6 and 39.2% for PNB and PWB, respectively). We found evidence that the bedding decreases the occurrence of oral stereotypies and lesions. The models developed showed that most reproductive variables were not affected by the treatments. The use of bedding caused negative alterations in thermodynamic aspects of the system higher specific enthalpy, with physiological variables indicating thermal stress. On the other hand, the evaluation of behavior and lesions indicated advantages related to the use of bedding. The similarity of the productive results obtained shows that the use of bedding and the group housing during all gestation period should be considered as viable practices. However, it is necessary to study climatization forms in the productive environment, in order to provide thermal comfort, in association with other requisites for animal welfare.
66

Análise de simulação de uso do Brise-Soleil como sistema de controle termal de uma fachada

Gomes, Diego de Miranda Mariath January 2018 (has links)
Submitted by Gisely Teixeira (gisely.teixeira@uniceub.br) on 2018-06-16T14:19:49Z No. of bitstreams: 1 51500353.pdf: 825277 bytes, checksum: c0a56c36defe2ac1db2657328abc32ff (MD5) / Made available in DSpace on 2018-06-16T14:19:49Z (GMT). No. of bitstreams: 1 51500353.pdf: 825277 bytes, checksum: c0a56c36defe2ac1db2657328abc32ff (MD5) Previous issue date: 2018 / O artigo simula a instalação de brise-soleil como sistema de controle termal de uma fachada em uma residência em Brasília, Distrito Federal. Levando-se em conta as características do cômodo e sua fachada oeste, foi escolhido o modelo de brise metálico retrátil. Os dados necessários para análise foram obtidos através do aplicativo para smartphone iCelsius e do equipamento portátil FLIR ONE. Os dados obtidos foram analisados apoiando-se em descrições técnicas obtidas pelo fabricante e a partir da bibliografia existente. Os resultados da simulação foram satisfatórios, uma vez que a utilização de brise-soleil como protetor solar diminui a temperatura do ambiente promovendo conforto térmico. Conclui-se que apesar do retorno financeiro pela substituição de aparelhos refrigeradores de ar por brise-soleil, não há garantia de satisfação total e descarte do uso desses aparelhos, uma vez que o conforto térmico é relativo para cada indivíduo, que pode desejar temperaturas ainda mais amenas.
67

Influência de muros vivos sobre o desempenho térmico de edifícios / Influence of living walls on the thermal performance of buildings

Caetano, Fernando Durso Neves, 1986- 11 September 2018 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-09-11T21:23:12Z (GMT). No. of bitstreams: 1 Caetano_FernandoDursoNeves_M.pdf: 9389633 bytes, checksum: 7a62543b1157c3e623a511236d0f40cc (MD5) Previous issue date: 2014 / Resumo: Nas cidades, os materiais utilizados para o revestimento do solo possuem propriedades que alteram o balanço dos ciclos naturais, induzindo a formação de fenômenos danosos como as ilhas de calor e as inundações urbanas. A partir desta constatação, atualmente muitas cidade vêm buscando uma recuperação da vegetação enquanto alternativa tecnologia que proporcione conforto ambiental sem prejudicar o desenvolvimento sustentável. Mas apesar de seu potencial para a amenização ambiental passiva, nem sempre é possível uma inserção considerável de áreas verdes nas cidades, tendo em vista que a valorização e demanda pelo uso do solo relegam-na a um segundo plano. Neste sentido, os revestimentos vegetais oferecem uma alternativa ao utilizarem a envoltória dos edifícios para introduzir a vegetação nas cidades; normalmente as coberturas e paredes dos edifícios configuram espaços subutilizados, mas com uma influência direta sobre o ambiente interno. Por causa disto, a tecnologia dos revestimentos vegetais tem atraído a atenção de muitos pesquisadores da área de clima urbano e conforto ambiental. Dentro deste contexto o trabalho aborda uma variação da tecnologia conhecida como muros vivos, que propõe a criação de uma pele vegetal sobre a alvenaria dos edifícios. A pesquisa teve como enfoque a análise térmica, utilizando para isto um delineamento experimental com medições comparativas. O objetivo principal consistiu em verificar a extensão em que o uso de um muro vivo externo influencia o comportamento térmico da envoltória e do interior de um edifício. O experimento ocorreu no campus da Universidade Estadual de Campinas, dentro da realidade construtiva e climática da região sudeste do Brasil. Durante a sua realização foram medidos parâmetros ambientais (temperaturas superficiais, do ar, e de globo negro; umidade relativa) em dois edifícios similares (um exposto e outro protegido com a pele verde) durante meses de verão (outubro de 2013 a janeiro de 2014). Além da influência sobre o comportamento térmico do edifício, a pesquisa também avaliou a viabilidade de uso de diferentes espécies vegetais em sistemas de muro vivo, assim como parâmetros técnicos referentes à irrigação, nutrição e fixação das plantas. Os principais resultados obtidos demonstraram que o sistema proporcionou um amortecimento térmico médio de até 19 °C na temperatura superficial externa da envoltória, e um atraso térmico médio de até 4 horas; no interior, a presença da pele verde proporcionou uma amenização média de até 2,73 °C na temperatura operativa no horário mais quente do dia típico / Abstract: In cities the materials used to cover the ground have properties that change the balance of natural cycles, leading to the shaping of harmful phenomena as the heat islands and urban floods. From this evidence many towns currently seek the restoration of vegetation cover as a way to provide environmental comfort without neglecting the sustainable development. But despite its potential for passive mitigation, not always the insertion of large green areas in cities is feasible due the high value and demand for land use. In this sense the green skins provide an alternative when using the buildings envelope in order to add vegetatios in cities; usually, the roofs and walls of buildings characterize underutilized areas, but with a direct influence on its internal environment. Because of this, the technology of vegetal coatings has attracted the attention of many researchers in the field of urban climate and environmental comfort. Within this context, this research addressed a variation of this technologies known as living walls, which proposes the creation of a vertical greenery system attached to the masonry of the buildings. The research had a focus on the thermal analysis, using for this an experimental approach with comparative measurements. Its main objective has been to verify the extent to which an external living wall influences the thermal behavior of the envelope and the interior of a building. The experiment took place at the State University of Campinas campus, within the constructive and climatic reality of southeastern Brazil. During its realization were measured environmental parameters (air, superficial, and black-globe temperatures; relative humidity) in two similar buildings (one exposed and other protected with the vegetal skin) during the summer months (October 2013 to January 2014). In addition, the research also evaluated the feasibility of using different plant species in the system, as well as technical parameters referring to irrigation, nutrition and plants attachment. The main results showed that the living wall provided an average thermal damping up to 19° C at the outer surface temperature of the envelope, and an average thermal lag of up to 4 hours for the warmer hours of the day; inside, the presence of the vegetal skin provided a mitigation up to 2,73 ° C in the operative temperature to the hottest hours of the average day / Mestrado / Arquitetura, Tecnologia e Cidade / Mestre em Arquitetura, Tecnologia e Cidade
68

Condições do escoamento e de conforto térmico em cabine de aeronave. / Air flow conditions and thermal comfort in aircraft.

Moura, Danilo de 19 February 2009 (has links)
A aviação comercial vem experimentando expressivo crescimento com elevado grau de competitividade. Produzir aeronaves com nível de conforto diferenciado transformou-se em importante ferramenta de marketing e de venda. Esta, porém, não é tarefa fácil. Cabines de aeronave apresentam condições de escoamento e de trocas térmicas que tornam bastante difícil prover e avaliar condições de conforto térmico. Para tentar resolver o problema, estudos estão sendo realizados em centros de pesquisa, em colaboração com a indústria aeronáutica. O presente trabalho se insere neste contexto. Neste trabalho foi realizado estudo do escoamento em cabine de aeronave, por meio de medição de variáveis ambientais de cabine, e de conforto térmico utilizando manequim térmico instrumentado e avaliação com pessoas. Para a realização dos ensaios foi projetado e construído mock-up de seção de cabine com 12 lugares. Foram analisadas condições do escoamento e de conforto térmico para duas condições de cabine, 19 e 24 °C. Nos ensaios com pessoas participaram 11 voluntários. Temperaturas equivalentes foram determinadas utilizando-se manequim térmico instrumentado e apresentadas em diagrama de sensação térmica previsto para este fim em norma técnica de veículos. Posteriormente, avaliações subjetivas, com resultados apresentados em diagramas de voto térmico médio (VTM) e de voto de conforto médio (VCM), foram realizadas. Verificou-se que, apesar das condições complexas do escoamento, não ocorreram diferenças significativas de velocidade do ar na região de ocupação e nem de temperatura na direção vertical, que são fatores que poderiam ocasionar grande desconforto. Verificou-se também a ocorrência de uma boa aproximação entre as avaliações de conforto térmico feitas por meio das temperaturas equivalentes e os resultados das análises subjetivas realizadas por meio de questionários. Nas avaliações subjetivas ocorreu um pequeno deslocamento dos resultados para o lado direito no diagrama de VTM. Finalmente, verificou-se que as pessoas preferiram as condições de cabine na temperatura de 19 °C, com votos de conforto médio (VCM) de indiferentes a ligeiramente confortáveis, enquanto na temperatura de cabine de 24 °C as condições foram consideradas ligeiramente desconfortáveis. / The commercial aviation has experienced an expressive growth with a high degree of competitiveness. The production of aircrafts with a higher comfort level has become an important tool for marketing and trading. However, this is not an easy task. Aircraft cabins present airflow and thermal transfer conditions that make quite difficult to provide and to evaluate thermal comfort conditions. In order to try to solve this problem, studies are being performed in research centers, in collaboration with the aeronautical industry. This project is inserted in this context. In this project a study of aircraft cabin airflow, through the measurement of the cabin environmental variables, and the thermal comfort using thermal mannequin and evaluation with people, was accomplished. For the accomplishment of the tests a mock-up of a cabin section with 12 places was projected and built. Conditions of airflow and thermal comfort within two cabin conditions, 19 and 24 °C, were analyzed. The tests with people were performed by 11 volunteers. Equivalent temperatures were obtained by using a thermal mannequin and were presented in a thermal sensation diagram, which had been seen to this purpose in vehicles technical norm. Later on, subjective evaluations, whose results were presented by an mean thermal vote (MTV) diagram and by an mean comfort vote (MCV) diagram, were accomplished. It was verified that, in spite of the complex airflow conditions, significant differences neither of the air velocity in the occupation area nor of the temperature in the vertical direction happened, which are factors that could cause a great discomfort. It was also verified a strong relation between thermal comfort evaluations accomplished through the equivalent temperatures and the results of the subjective analyses accomplished through questionnaires. In the subjective evaluations, a small displacement of the results to the right side in the MTV diagram occurred. Finally, it was verified that the volunteers preferred 19 °C temperature cabin condition, with mean comfort votes (MCV) indicating from indifferent to lightly comfortable conditions, while in the 24 °C cabin the conditions were considered lightly uncomfortable.
69

Bem-estar de matrizes suínas em gestação: Estimativa da condição de conforto térmico, análise comportamental e produtiva no alojamento coletivo com uso de cama / Welfare of gestating sows: an estimate of thermal comfort conditions, behavioral and productive analysis in group housing with the use of bedding

Maria Luisa Appendino Nunes 16 January 2012 (has links)
A discussão do bem-estar de matrizes suínas gestantes é um tema em destaque em função do uso de gaiolas individuais. Assim, é urgente a geração de conhecimentos voltados ao alojamento coletivo. Objetivou-se com esta pesquisa avaliar aspectos produtivos, comportamentais, fisiológicos e bioclimáticos resultantes do uso de cama na fase de gestação suína, em diferentes sistemas de alojamento. O experimento foi realizado no Município de Itu/SP, entre os meses de janeiro e setembro de 2010, durante 2 ciclos de gestação (experimentos 1 e 2). Em cada ciclo foram alojadas 216 porcas gestantes em quatro tratamentos de forma a avaliar: tipo de alojamento (combinado - GB ou coletivo B) e tipo de piso (cama de maravalha - CC ou concreto - SC). No capítulo 3 foram avaliadas características físicas do ambiente e indicadores fisiológicos de conforto térmico. No capítulo 4 foram avaliados os padrões comportamentais nos tratamentos, bem como resultados reprodutivos. Foram verificadas piores condições microclimáticas em cama (P<0,05), com aumento da temperatura e entalpia específica do ar (1,14 ºC e 2,37 kJ/kg ar seco, respectivamente). No experimento 2, ocorreu interação (P<0,05) entre horário e presença de cama, de forma que somente nos horários da manhã e meio dia a presença de cama implicou em aumento da temperatura e entalpia específica do ar. No experimento 1, a temperatura do piso na área suja apresentou-se maior em cama, com um aumento de 2,61 ºC (P<0,05). O mesmo ocorreu no experimento 2, no entanto, com interação entre temperatura do piso na área suja e horário. Em geral, a temperatura do piso na área limpa apresentou-se maior nos sistemas SC. No experimento 1 a temperatura retal não diferiu significativamente (P>0,05), diferentemente do experimento 2 no qual foi observado aumento significativo na presença cama. Em ambos os experimentos, a temperatura da pele e frequência respiratória apresentaram-se maiores em cama. Fêmeas mantidas em cama tiveram maiores frequências na postura em pé (20,9 e 31,4% para GBSC e GBCC e 20,6 e 39,2% para BSC e BCC, respectivamente). Foram encontradas evidências de que a cama diminui a ocorrência de estereotipias orais e lesões corporais. Os modelos desenvolvidos mostraram que a maioria das variáveis reprodutivas não foi afetada pelos tratamentos. O uso de cama alterou negativamente aspectos bioclimáticos do sistema, expresso na maior entalpia específica do ar, com as variáveis fisiológicas indicando maior estresse por calor. Por outro lado, a avaliação comportamental e de lesões indicou vantagens relacionadas ao uso de cama. A similaridade dos resultados produtivos obtidos mostra que o uso de cama e o alojamento em grupo durante toda a gestação devem ser considerados, no entanto, devem ser estudadas formas de climatização do ambiente produtivo para permitir bemestar térmico, associado a outros quesitos do bem-estar animal. / The increased concern about animal welfare in the world is evident. In this area, the housing system of gestating sows is especially significant due to the use of individual cages. Thus, the generation of knowledge of group housing is urgent. Information on the use of bedding for these animals in the Brazilian climate is scarce. The purpose of this research was to evaluate productive, behavioral, physiological and bioclimatic aspects resulting from the use of bedding in the gestation period of sows, in different housing systems. The experiments were conducted in Itu, state of São Paulo, between January and September 2010, during two gestation periods (experiments 1 and 2). In each period 216 gestating sows were housed in four treatments, in order to evaluate the type of housing CP or P (cage and pen - CP or en - P) and the type of floor WB or NB (wood shaving bedding/with bedding WB or concrete/no bedding - NB). In Chapter 3 we analyzed the physical characteristics of the environment and the physiological indicators of thermal comfort. In chapter 4 we evaluated the behavioral patterns in the treatments, as well as the reproductive results. Worse microclimatic conditions were observed in the bedding (P<0.05), with increase in temperature and in specific enthalpy of air (1.14 ºC and 2.37 kJ/kg dry air, respectively). In experiment 2 there was interaction (P<0.05) between the time and the presence of bedding. Only in the morning and at noon the presence of bedding caused increase in temperature and in specific enthalpy of air. In experiment 1, the floor temperature in the dirty area was higher with the use of bedding, with an increase of 2.61 ºC (P<0.05). The same occurred in experiment 2, but there was interaction between floor temperature in the dirty area and the time. In general, the floor temperature in the clean area was higher in the NB systems. In experiment 1, the rectal temperature did not differ significantly in the treatments (P<0.05), whereas experiment 2 showed higher rectal temperature in the presence of bedding. In both experiments, skin temperature and respiratory rate were higher in the bedding. Sows kept in the bedding system had higher rates of standing posture (20.9 and 31.4% for CPNB and CPWB and 20.6 and 39.2% for PNB and PWB, respectively). We found evidence that the bedding decreases the occurrence of oral stereotypies and lesions. The models developed showed that most reproductive variables were not affected by the treatments. The use of bedding caused negative alterations in thermodynamic aspects of the system higher specific enthalpy, with physiological variables indicating thermal stress. On the other hand, the evaluation of behavior and lesions indicated advantages related to the use of bedding. The similarity of the productive results obtained shows that the use of bedding and the group housing during all gestation period should be considered as viable practices. However, it is necessary to study climatization forms in the productive environment, in order to provide thermal comfort, in association with other requisites for animal welfare.
70

Subcoberturas: aplicação de isolantes térmicos em sistemas de coberturas / not available

Carletto, Consuelo 20 May 2005 (has links)
Este trabalho tem como foco principal apresentar os resultados e as contribuições da pesquisa experimental comparativa de subcoberturas em sistemas de cobertura. Para tal fim foram utilizados quatro protótipos localizados no canteiro experimental do CRHEA - EESC em São Carlos, São Paulo. Os protótipos foram construídos da mesma forma e com os mesmos materiais: tijolo comum, laje cerâmica recapeada com concreto; cobertos com telhas de fibrocimento e submetidos às mesmas excitações de clima ao ar livre. A análise foi feita aplicando um curto intervalo de clima, com respaldo teórico da climatologia dinâmica. Um dos protótipos serviu como testemunho e não recebeu a instalação de nenhuma subcobertura. Os outros três receberam cada um, respectivamente, subcobertura de foil (isolante por reflexão, ou barreira de radiação), lã de rocha (isolante convencional, condutividade térmica k) e de caixas cartonadas Tetra Pak, um resíduo, como isolante por reflexão e câmara de ar, já que foram utilizadas fechadas e uma ao lado da outra. Foram monitoradas as temperaturas superficiais da telha e da laje e, das temperaturas de bulbo seco no ático e na parte interna dos protótipos a 1,10 m de altura. As medidas de aquisições de dados foram feitas através de CR10X Campbell Scientific automático com medições em 30 segundos, armazenados e totalizados em 30 minutos, o que resultou em valores de clima ao livre e em recinto fechado muito precisos. / Thermal comfort achievement can be done by using thermal reflexive barriers, meaning energy savings and avoiding health problems of air conditioning. It can also be done by using building construction waste materials as Tetra Pak boxes, a low cost reflexive insulation, and applying an industrial \"foil\" which the same effect on reducing indoor air temperatures. In the same way traditional thermal insulation materials were used on this research as the mineral wool (conventional insulation material, thermal conductivity - k values). The analysis was made applying short intervals of climate such as recommended by the dynamic climatic approach. The use of foil insulation can be justified because of its behavior as a reflective barrier and because it has a lot of acceptation; mineral wool (mineral source with low k insulation values) for being a traditional kind of thermal insulation and the Tetra Pak box, because it is a reflective insulation and also because of its waste recycle usage characteristic. The research shows the insulation thermal efficiency applied on three kinds of fiber asbestos cover system, which makes the indoor air temperatures inside of comfort zones values, as intended to expose by graphics, made by real time and automatic experimental measurements. The measurements of data acquisitions were made by automatic CR10X Campbell Scientific Inc., 30 seconds scanner and totalized storage as 30 minutes average intervals. This means a very accurate result of values of outdoor and indoor climate translated by indoor and out door air temperatures.

Page generated in 0.0721 seconds