• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 262
  • 207
  • 26
  • 25
  • 18
  • 11
  • 10
  • 9
  • 8
  • 6
  • 6
  • 3
  • 2
  • 2
  • 2
  • Tagged with
  • 713
  • 123
  • 114
  • 99
  • 92
  • 86
  • 84
  • 81
  • 76
  • 68
  • 66
  • 64
  • 57
  • 56
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Análise teórica e experimental de treliças espaciais / Theoretical and experimental analysis of space trusses

Souza, Alex Sander Clemente de 27 March 2003 (has links)
Este trabalho apresenta um estudo sobre o comportamento de treliças espaciais formadas por elementos tubulares de seção circular, com ênfase no desempenho das tipologias de ligação utilizadas no Brasil. Foram ensaiadas experimentalmente 9 treliças espaciais com vãos de 7,5 x 15,0m e uma de 7,5m x 7,5m com altura de 1,5m, variando-se o tipo de ligação entre barras, com o objetivo de caracterizar e comparar o comportamento dos sistemas de ligações mais comuns (nó típico – extremidade estampada, nó de aço e nó com chapa de ponteira).A análise teórica, via elementos finitos, tem como objetivo aferir a validade dos modelos numéricos normalmente utilizados e refiná-los incluindo as características do comportamento estrutural observadas em ensaio. A análise numérica segue duas abordagens: análise global da estrutura incluindo os efeitos não-lineares, excentricidade na ligação e variação de seção nas extremidades das barras; com isso o comportamento das treliças ensaiadas foi representado de forma satisfatória. A análise do comportamento do nó típico, modelado tridimensionalmente com elementos de casca, possibilitou analisar a interação entre as barras na região nodal por meio de elementos de contato. Com esta modelagem, apesar das simplificações, foi possível reproduzir o modo de colapso observado experimentalmente. / This paper presents a study of the behavior of tubular circular section space trusses with the main emphasis placed on the performance of the various truss typologies used in Brazil. Nine space trusses with plan dimensions of 7.5m x 15.0m and one with plan dimensions of 7.5mx7.5m and height of 1.5m were tested. The joint type was varied with the objective to characterize and compare the behavior of the more common types of connection systems (typical node – stamped end, steel node, and end plate node). The theoretical analysis employing finite elements was adopted mainly to ascertain the validity of various numerical models commonly employed and hence refining them by including the some basic characteristics of the observed structural behavior.The numerical analysis employed was based on two methodologies: a global structural analysis that takes into account the effects of non-linearity, eccentricities at connection, and the variation of the end bars cross section. In this manner the actual behavior of the tested trusses was well represented. The analysis of the behavior of a typical node, modeled using tri-dimensional finite shell elements made it possible to analyze the interaction between bars that converge at the nodal region by applying contact elements. Despite it simplicity, predicted results of the collapse mode obtained by using the proposed model, very well reproduce the experimental observation.
222

Influência da rugosidade superficial e o uso de novos tipos de fibras em almofadas de argamassa para ligações de concreto pré-moldado / Influence of surface roughness and the use of new types of fiber in bearing pads of cement-based material for precast concrete connections

Bellucio, Ellen Kellen 12 March 2010 (has links)
Este trabalho apresenta o estudo de uma argamassa modificada para ser utilizada como almofada de apoio em ligações entre elementos de concreto pré-moldado. Esta argamassa é composta de cimento e areia, com a adição de látex estireno-butadieno (SB), agregado leve (vermiculita) e fibras curtas (polipropileno, vidro e PVA). As pesquisas anteriores mostraram que este compósito apresentou uma boa resistência à compressão e baixo módulo de elasticidade. O objetivo desta pesquisa é dar continuidade dos estudos anteriores analisando a influência da rugosidade superficial nas almofadas, introduzida para aumentar a sua deformabilidade e testar diferentes tipos de fibras. A rugosidade é analisada comparando placas com ambos os lados lisos, um lado liso e outro rugoso e ambos os lados rugosos. Foram estudadas dois tipos de fibras de polipropileno de 10 mm de comprimento - uma com 12 \'mü\'m e outra com 180 \'mü\'m de diâmetro. Nesta pesquisa foram realizados ensaios de caracterização do compósito (compressão simples, tração por compressão diametral e módulo de elasticidade) e ensaios em placas (compressão centrada monotônica e cíclica, força concentrada e flexão). Os resultados de caracterização apontam um bom comportamento do compósito, com resistência à compressão de 41 MPa e módulo de elasticidade de 12,8 GPa. Os ensaios de placas mostram melhores resultados para fibras de 12 \'mü\'m de diâmetro em função de: a) uma redução de 30% da rigidez nos ensaios monotônicos em relação a uma argamassa de referência, b) melhor capacidade de absorção de carga no ensaio de força concentrada e c) no ensaio de flexão, um índice de tenacidade 40% maior quando comparadas com os outros traços estudados. Na análise da rugosidade superficial, o melhor resultado é com rugosidade em ambos os lados da placa, sendo que nos ensaios de carregamento monotônico e cíclico houve uma redução de até 30% na rigidez e um aumento do afundamento acumulado de mais de 120% em relação às placas com ambos os lados lisos. / This paper presents the study of a mortar modified to be used as a bearing pad connections between precast concrete elements. This mortar is composed of cement and sand, with the addition of styrene-butadiene latex (SB), lightweight aggregate (vermiculite) and short fibers (polypropylene, glass and PVA). Previous research showed that this composite presents good compressive strength and low modulus of elasticity. The objective of this research is to continue the previous studies, analyzing the influence of surface roughness on the pads, introduced to increase its deformability, and test other types of fibers. The roughness is analyzed by comparing bearing pads with both smooth sides, one side smooth and other rough and rough both sides. Two types of polypropylene fibers of 10 mm in length - one with 12 \'mü\'m and another with 180 \'mü\'m in diameter are studies. In this research, test were carry out to characterize the composite (compressive strength, tensile strength by diametral compression and modulus of elasticity) and test on bearing pads (uniform compressive load - monotonic and cyclic, concentrated load and bending). The results on cylindrical samples to characterize the composite indicate a good behavior, the compressive strength of 41 MPa and modulus of elasticity of 12.8 GPa. The test bearing pads presents the best results for fibers of 12 \'mü\'m of diameter in terms of: a) a 30% reduction of stiffness in the monotonic tests in relation to a reference mortar, b) the best ability to absorb the load test concentrated load and c) the bending test, an index of toughness 40% higher when compared with the other mixture studied. Regarding surface roughness analysis, the best result is with roughness on both sides of the bearing pads, and tests of monotonic and cyclic loading are reduced by 30% in stiffness and an increase in deformation accumulated more than 120% bearing pads regarding with both sides smooth.
223

Modelagem numérica e análise de modos de falha de conexões entre tubulares de revestimento de poços / Numerical modeling and failure analysis of casing connections

Mantilla Uribe, Juan Camilo 18 April 2017 (has links)
Dependendo da magnitude, falhas na coluna de revestimento podem gerar grandes perdas econômicas e ambientais. Dada a complicada revisão e manutenção do revestimento durante a operação do poço, este deve ser projetado com robustez suficiente para suportar as solicitações em sua vida útil. As conexões de revestimento têm sido consideradas na literatura como os componentes mais propensos à falha. Testes são geralmente utilizados para qualificar a capacidade última das conexões no projeto de revestimento; porém, tendem a ser caros e demandam tempo considerável. Com o objetivo de diminuir os custos dos testes, modelos em elementos finitos são amplamente usados como alternativa e em complemento aos testes para avaliar o comportamento das conexões. Este trabalho apresenta um estudo de conexões de revestimento com base em modelos em elementos finitos, considerando a aplicação de torque de aperto, tração e pressão interna, tomando como caso de estudo uma conexão API 8 Round LTC 9 5/8 47 lb/ft L80. Na modelagem numérica adota-se axissimetría, a inclusão da elastoplasticidade com endurecimento isotrópico controlado pela superfície de falha de Von Mises, não linearidade geométrica e modelagem de contato para grandes deslizamentos com inclusão de fricção tangencial às superfícies de contato. Com uso de critérios mencionados na literatura e hipóteses de falha - principalmente dadas em função das pressões nos filetes, afastamento entre filetes e excessiva plasticidade - o modelo em elementos finitos desenvolvido foi utilizado para avaliar a capacidade da conexão ante os modos de falha por desacoplamento e vazamento. Os resultados da análise são satisfatórios quando comparados às resistências calculadas pela normativa API, e dados e observações experimentais presentes nas referências. Do estudo obtém-se um método para modelagem, que permite reproduzir os fenômenos observados em conexões de revestimento e estimar os modos de falha, podendo ser estendida a análise para conexões com diferentes geometrias. Este estudo é a base para pesquisas futuras sobre modelagem em elementos finitos de testes de conexões, definição de estados limites e de estudos de confiabilidade estrutural em conexões de revestimento de poço. / Casing failures can potentially generate large economic losses and environmental damages, depending on their magnitude. Opportunities for casing evaluation and repair during operation are limited; hence, casing has to be designed with sufficient robustness to bear the loads applied during service life. Casing connections have been considered in the literature as the weak points of the casing column, following observed failures. Testing is generally used to qualify connections; however, they are expensive and demand a lot of time. Aiming to diminish the costs of testing, finite element models are widely used as an alternative and complement to tests to evaluate the behavior of casing connections. This work proposes to study casing connections using finite element models, considering the application of loads of make-up, traction, and internal pressure, taking for study case an API 8 Round LTC 9 5/8 casing connection. The finite element modeling assumed axisymmetry, elastoplastic material with isotropic hardening controlled by the Von Mises yielding surface, geometrical non linearity and inclusion of contact formulation for large slides and tangential frictional behavior between the casing connection mating surfaces. Using criteria mentioned in the literature - mainly in function of flank contact pressures, opening between flanks and effects of excessive plasticity - the developed finite element model was used to evaluate the capacity of the connection for jump-out and leakage failure modes. The results of the analyses were satisfactory when compared to the capacity calculated by the API standards, and experimental observations presented in the literature. From the study, a methodology is obtained for finite element modeling of casing connections, allowing study of the behavior and analysis of failure modes in casing connections, which can be extended for connections with different geometries. This study is the base for future investigations on finite element modeling of connection testing, on limit state definition for various failure modes, and for the study of structural reliability of casing connections.
224

Ligações e armaduras de lajes em vigas mistas de aço e de concreto. / Connections and slab reinforcement of concrete-steel composite beams.

Fuzihara, Marisa Aparecida Leonel da Silva 24 November 2006 (has links)
As vigas mistas de aço-concreto vêm ganhando espaço no mundo e no Brasil. Sua grande vantagem é o aproveitamento das melhores propriedades que cada material apresenta. O aço possui excelente resposta para esforços tanto de tração como os de compressão e o concreto para esforços de compressão. As vigas mistas envolvem basicamente o perfil de aço, a laje de concreto, os conectores e as armaduras. Na interface destes materiais ocorrem fenômenos que merecem destaque, como grau de interação, cisalhamento na superfície de contato e separação vertical. Os procedimentos normalmente empregados em projetos de estruturas convencionais de concreto armado e de aço fornecem muitas respostas para questões semelhantes nas estruturas mistas, porém, no geral, não abordam a questão mais relevante que é a ligação entre o aço e o concreto. Na vizinhança dos conectores de cisalhamento, a laje da viga mista de aço e concreto está sujeita a uma combinação de cisalhamento longitudinal e momento fletor transversal, por isso a interface é a região que necessita de uma análise cuidadosa. Esses aspectos são os objetos principais da pesquisa. Adicionalmente são discutidos os procedimentos de projetos adotados pelas normas brasileira (NBR 8800-86), americana (AISC) e européia (EUROCODE 4): nas regiões de ligações entre os materiais por meio de conectores em perfis de aço sob lajes de concreto, no controle da fissuração em seções solicitadas por momentos negativos e nas armaduras transversais de costura. / The use of composite steel-concrete beams is increasing in Brazil and in the world, because this is to take advantage of the best properties of each material. Steel has an excellent response to compression and tension and concrete has to compression. Composite beams include basically the steel beam, concrete slab, connectors and reinforcement. Some phenomena in the interface of these materials must be considered, like the degree of interaction, shear in contact surface and uplift. The procedures normally taken in design of conventional structures of reinforced concrete and steel structures supply many answers to similar questions in composite structures, but, in general, they do not approach the most relevant question which is the bond between steel and concrete. The slab of composite steel-concrete beam is affected by a combination of longitudinal shear and transverse flexure, in the neighborhood of the shear connector. The analysis of the behavior of the slab and the reinforcement are main aspect of the work. In addition, some design procedures adopted by Brazilian Standard (NBR 8800-86), American Standard (AISC-2005) and European standard (EUROCODE 4) are discussed, in especial the related to connects, the crack control in sections with hogging moment and in transverse reinforcement.
225

Análise numérica, via M.E.F., do comportamento de ligações parafusadas viga-coluna com chapa de topo / Numerical analysis, by F.E.M, of bolted beam-to-column end plate connection behavior

Maggi, Yuri Ivan 31 March 2000 (has links)
Este trabalho apresenta uma análise numérica sobre o comportamento estrutural das ligações parafusadas viga-coluna com chapa de topo. São estudados dois métodos tradicionais de dimensionamento e são apresentados cinco sistemas de classificação propostos para as ligações. Modelos numéricos das ligações estudadas são preparados com a utilização de elementos finitos e os resultados numéricos são comparados com resultados experimentais conhecidos. São abordados aspectos relativos às propostas de dimensionamento, em comparação com os resultados numéricos e experimentais. Em particular, é discutida a rigidez das ligações, verificando-se a influência da variação da espessura da chapa de topo e diâmetro dos parafusos. Com a comparação entre resultados numéricos e experimentais, é analisada a representatividade dos modelos numéricos com relação ao comportamento das ligações estudadas. Finalmente, são apresentadas as conclusões e recomendações para futuras pesquisas / This work presents a numerical analysis on the structural behavior of bolted beam-to-column end plate connection. Two traditional design methods are studied and five proposed classification systems for connections are presented. Numerical models representing the studied connections are prepared using finite elements and numerical results are compared with existing experimental results. The design proposals are compared with numerical and experimental results. In particular, the connection rigidity is discussed by verifying the influence of variations in end plate thickness and bolt diameter. Comparing numerical and experimental results the reliability of F.E.M models is appraised. Finally, conclusions are presented with some suggestions for future researches
226

Empirical essays on the economic analysis of social connections

Colussi, Tommaso January 2014 (has links)
Social connections represent an important determinant of economic agents’ behaviour. The three chapters of this thesis empirically analyse the effect of different types of networks on several economic outcomes. The first chapter analyses the role played by co-worker networks on immigrants’ employment outcomes. It investigates how immigrants’ job search outcomes are affected by the labour market outcomes of co-workers from the same country of origin. Using matched employer-employee micro data from Italy and an instrumental variables approach, I show that an increase in the employment prospects of socially connected workers improves immigrants’ job search outcomes. The paper also sheds light on the different mechanisms generating the social effect and it highlights the role of migrant networks in explaining immigrant segregation. Chapter 2 employs a unique dataset on articles, authors and editors of the top four economics journals over the period 2000-2006 to investigate the role of social ties in the publication process. Connections between editors and authors are identified based on their academic histories. Regression results show that the existence of a social tie with an editor positively affects publication outcomes of connected scholars. The analysis of citations shows that connected articles receive on average a higher number of citations than non-connected ones. The final chapter focuses on the impact of female managers on female workers’ employment outcomes. Exploiting changes in the share of female managers induced by firms’ takeovers, I find no statistically significant effect of an increase in the presence of female managers on employment outcomes of female workers. However there is an interesting negative effect on wage inequality within the acquiring firm, which may matter for both equity and efficiency reasons.
227

Análise do comportamento estrutural de ligações parafusadas viga-pilar com chapa de topo estendida / Analysis of the structural behavior of bolted beam-column extended end plate connections

Maggi, Yuri Ivan 26 May 2004 (has links)
Este trabalho apresenta uma análise numérica e experimental sobre o comportamento estrutural de ligações parafusadas viga-pilar com chapa de topo estendida. Discute-se, em particular, o comportamento da chapa de topo e dos parafusos na determinação da capacidade resistente dessas ligações. A análise de resultados numéricos é utilizada como base para as discussões neste trabalho e a modelagem numérica, realizada em elementos finitos com o software ANSYS, incluiu modelos tridimensionais de ligações com chapa de topo estendida e de ligações duplo “T". Com os resultados numéricos e experimentais, os mecanismos de transferência dos esforços entre viga e pilar e os mecanismos de plastificação da chapa de topo e dos parafusos são observados, avaliando-se as linhas de plastificação na chapa de topo em confronto com a metodologia proposta pelo Eurocode 3 na determinação dos perfis “T" equivalentes. Para esses fatores, observou-se que os modos de falha indicados pelo Eurocode 3 não representam satisfatoriamente o comportamento das ligações analisadas. A modelagem numérica, por sua vez, mostrou-se generalista e representativa como ferramenta para análises paramétricas e como complemento de análises experimentais / This work presents a numerical and experimental analysis on the structural behavior of bolted beam-column extended end plate connections. The behavior of the end plate and bolts used in the calculations of the end plate strength is specially discussed. Numerical results are used as basis to the discussions presented in this work and the modeling methodology, with FE models built with the ANSYS code, included 3D models of extended end plate and T-stub connections. The beam-to-column load transfer mechanisms and the yielding mechanisms at end plates and bolts are observed using numerical and experimental results. The yielding lines at the end plate are evaluated against the methodology proposed by Eurocode 3 for the calculations on the equivalent T-stub. Regarding the aforementioned factors, it is shown that the collapse modes indicated by Eurocode 3 do not represent satisfactorily the behavior of the analyzed connections. The numerical modeling was found to be general in application and reliable as a tool for parametric analyses and as a complement to experiments
228

Análise numérica de ligações metálicas viga-coluna com coluna tubular circular / Numerical analysis of steel beam-to-column connection with circular hollow section column

Freitas, Pedro César de Barros 02 June 2009 (has links)
As estruturas tubulares, muitas vezes, têm sua aplicação restrita a construções onde a concepção arquitetônica determina o seu uso, no entanto há algumas vantagens do ponto de vista estrutural que podem justificar a sua aplicação. A reduzida área exposta ao fogo e aos ambientes agressivos, boa resistência a compressão axial com baixa tendência ao desenvolvimento de instabilidades localizadas, são algumas das vantagens da utilização destas estruturas. O objetivo principal deste trabalho é analisar numericamente o comportamento da ligação entre viga de seção I com coluna tubular circular, para tanto são consideradas configurações usuais de ligação com anéis externos transversais e chapa de alma. É ainda objetivo trazer um panorama das estruturas tubulares em geral, com o desenvolvimento histórico das pesquisas, e principalmente estabelecer uma compilação dos procedimentos analíticos de cálculo e classificação apresentados pelas normas Eurocode 3 e ANSI/AISC. A análise numérica foi realizada por meio dos pacotes comerciais TRUEGRID® e ANSYS®, os quais aplicam o método dos elementos finitos. Foram empregados modelos que consideram as características mecânicas do aço, como plastificação e encruamento, e ainda as não-linearidades geométricas e de contato. Os resultados numéricos apresentaram coerência razoável com os modelos analíticos normativos. Foi possível o conhecimento do comportamento M-\'fi\' (momento-rotação) das ligações, bem como a determinação dos parâmetros que caracterizam tal relação, como resistência, rigidez inicial e ductilidade. Os estudos comprovaram a eficácia dos anéis externos na distribuição dos esforços oriundos do engastamento parcial da viga, fazendo com que a coluna não seja comprometida. / The application of tubular structures is usually restricted to constructions on which the architectural conception demands them. However, there are also several structural advantages which justify their usage, such as a) reduced exposed area concerning fire and agressive environments; b) high axial compression resistance; c) high local buckling resistance. The aim of this work is the numerical analysis on the behavior of the I beam-circular hollow column connection, usually constituted by an external ring with single plate. It is presented a general view about the researchers development over the years on tubular structures focusing the compilation of the analytical design procedures and Eurocode 3 and ANSI/AISC classification as well. Finite element method softwares TRUEGRID and ANSYS are used for the numerical analysis in order to consider steel mechanical properties such as yielding, hardening and also geometric and contact nonlinearities. Numerical results present good agreement to codes\' analytical models. Analysis lead to understanding the connection\'s moment-rotation behavior and some of its parameters such as resistance, initial stiffness and ductility. It is shown external rings significantlly improve the semi-rigid connections stress distribution at the columns face.
229

Análise da resposta numérica de ligações parafusadas em chapas finas e perfis formados a frio / Analyzes of the numerical answer of the bolted connections of cold-formed steel members

Pedro Gonçalves de Rezende 23 September 2005 (has links)
A utilização de perfis formados a frio na construção metálica no Brasil vem crescendo de forma significativa. Dentro deste mesmo contexto, atenções especiais estão sendo direcionadas às ligações utilizadas neste tipo de perfil, pelo fato de as chapas que as constituem resultarem cada vez mais esbeltas em função da significativa redução na sua espessura (elevada relação largura/espessura). Por esta razão, as ligações em perfis formados a frio têm sido estudadas por pesquisadores, tanto no contexto mundial como no Brasil. Neste sentido, o presente trabalho tem por objetivo realizar estudos relacionados às ligações parafusadas em perfis formados a frio, com vistas a avaliar a resistência e o comportamento destas ligações por meio de modelagem numérica, simulando o comportamento estrutural com a utilização do código de cálculo ANSYS v.6.0, elaborado com base nos Métodos dos Elementos Finitos (MEF). No sentido de avaliar a eficiência e a confiabilidade dos modelos elaborados, os resultados numéricos obtidos foram comparados com resultados experimentais obtidos em ensaios, bem como, comparados com resultados numéricos obtidos utilizando-se outros padrões de modelagem. / The use of cold-formed steel members in the steel building in Brazil comes growing of significant form. Inside of the same context, special attentions are being directed to the connections used in the cold-formed steel members, or the fact of the sheets used to this kind of steel members result each time more thin. For this reason the connections in cold-formed steel members have been studied for researchers, as much in the worldwide context as in Brazil. The objective of this work is studies the bolted connections in cold-formed steel member to evaluate the resistance and the behavior of these connections by means of numerical modeling, simulating the structural behavior with the use of the code of calculation ANSYS v.6.0, elaborated based on Finite Element Methods. With the objective to evaluate the efficiency and the trustworthiness of the elaborated model, the numerical results where compare with experimental results gotten in assays, as well as, compared with numerical results gotten using other standards of modeling.
230

Rotational Stiffness Models for Shallow Embedded Column-to-Footing Connections

Sadler, Ashley Lauren 01 March 2018 (has links)
Shallow embedded steel column connections are widely used in steel buildings; however, there is insufficient research about this connection type to understand the actual rotational stiffness that the connection provides. Shallow embedded steel columns are when a steel column is anchored to the foundation slab and then unreinforced concrete is poured around the base plate and the base of the column. This thesis seeks to further quantify the rotational stiffness available in this type of connection due to the added concrete and improve an existing model in order to represent the rotational stiffness. Existing data from two series of experiments on shallow embedded columns were used to validate and improve an existing rotational stiffness model. These two data sets were reduced in the same manner so that they could be compared to one another. In addition, the rotational stiffness for each test column was determined so they could be evaluated against the outputs of the model. The existing model was improved by evaluating each parameter in the model: the modulus of subgrade reaction, exposed column length, modulus of concrete for the blockout and the foundation slab, flange effective width, embedment depth, and effective column depth. It was determined that the model was sensitive to the subgrade reaction, modulus of concrete, embedment depth and effective column depth. The exposed length was not a highly sensitive parameter to the model. Flange effective width was determined to not be needed, especially when the other parameters were altered.

Page generated in 0.1109 seconds