Spelling suggestions: "subject:"crômio"" "subject:"crômico""
1 |
Eletrodos impressos modificados com poli-histidina aplicados na construção de sensores eletroquímicos para crômio(VI) e fármacosBergamini, Márcio Fernando [UNESP] January 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2007Bitstream added on 2014-06-13T20:06:30Z : No. of bitstreams: 1
bergamini_mf_dr_araiq.pdf: 1136737 bytes, checksum: 545d37fbd4099b82c41b74dd54c5ab6f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O presente trabalho investiga a aplicação de eletrodos impressos, de carbono (SPCE) e ouro (SPGE), na determinação de espécies de interesse farmacêutico, tais como, aurotiomalato, L-dopa e procaína, utilizando sistemas convencionais, com fluxo de solução e análise por injeção em fluxo, respectivamente. Após a otimização de todos os parâmetros voltamétricos e inerentes da técnica construí-se curvas analíticas para cada composto farmacêutico com respostas lineares entre concentrações de 1,4 x 10-6 a 1,5 x 10-4 mol L-1, 1,5 x 10-6 a 6,6 x 10-4 mol L-1 e 1,0 x 10-5 a 1,0 x 10-4 mol L-1 para o aurotiomalato, a L-dopa e a procaína, respectivamente. O método foi aplicado na determinação dessas espécies em formulações farmacêuticas. A construção e caracterização voltamétrica de. eletrodos de carbono impresso (SPCE) por filmes de poli-histidina (PH) foi também investigada com intuito de ampliar o nível de sensibilidade e seletividade dos métodos voltamétricos. Para isso, foram testados três diferentes procedimentos de para a construção dos eletrodos modificados: a adição direta de uma solução do polímero (SPCE/PH), a utilização de uma reação cruzada entre a poli-histidina e o glutaraldeído (SPCE/Glu-PH) e a eletropolimerização a partir do monômero histidina (SPCE/EPH). O comportamento voltamétrico dos eletrodos modificados mostrou-se fortemente dependente do procedimento de preparação dos filmes. Eletrodos SPCE/PH e SPCE/Glu-PH apresentaram uma alta eficiência na pré-concentração de ânions, como o ferricianeto. Não sendo observado nenhum efeito eletrocatalítico para a oxidação de ácido ascórbico com esses eletrodos. Já para o SPCE/EPH foi observado um baixo desempenho na pré-concentração de ânions, mas um pronunciado efeito eletrocatalítico para a oxidação de ácido ascórbico. A aderência e estabilidade das respostas obtidas... / The present work investigated the application of screen-printed carbon (SPCE) and screen-printed gold electrodes (SPGE) in the determination of species of pharmaceutical interest, such as, aurothiomalate, L-dopa and procaine. The performance of all electrodes was tested in a conventional electrochemical system, and also in two electrochemical cells using amperometric detection. The first one was constructed to operate on hydrodynamic system and the second one to work on flow injection analysis (FIA) system. Analytical curves were obtained for all systems with linear relationship from peak current vs concentration from 1.4 x 10-6 to 1.5 x 10-4 mol L-1 for aurothiomalate; 1.5 x 10-6 to 6.6 x 10-4 mol L-1 for L-dopa and 1.0 x 10-5 to 1.0 x 10-4 mol L-1 for procaine, respectively. The method was tested in pharmaceutical compounds with good recovery. Screen-printed carbon electrodes (SPCE) can be easily modified with poly-histidine (PH) films using three different procedures: by direct addition of a poly-histidine solution on the electrode surface (SPCE/PH), using a cross-link reaction between poly-histidine and glutaraldehyde (SPCE/Glu-PH) and by electropolymerization of the histidine monomer (SPCE/EPH). The voltammetric behavior of the three modified electrodes was evaluated using potassium hexacyanoferrate(III) and ascorbic acid as model compounds. All modified electrode from stable films, but SPCE coated by deposition of PH and Glu-PH presented higher efficiency for pre concentration anions, while SPCE coated by electropolymerization of the monomer (EPH) presented pronounced electrocatalytic effect in the ascorbic acid oxidation. The resulting PH films presented good adherence and high stabilities and they were applied in the voltammetric analysis of isoniazide, pyrazinamide, aurothiomalate and chromium (VI). The best experimental condition for isoniazide and pyrazinamide...(Complete abstract click electronic access below)
|
2 |
Avaliação da contaminação, por crômio, em ecossistemas aquáticos, nas proximidades de indústrias de curtimento de couros em Minas Gerais / Evaluation of chromium contamination in aquatic ecosystems by tannery factories in Minas Gerais, BrazilSilva, Alessandro Costa da 27 September 1996 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-08-26T18:28:29Z
No. of bitstreams: 1
texto completo.pdf: 8157414 bytes, checksum: e5c01d282431be7897b90d48b305fcd9 (MD5) / Made available in DSpace on 2016-08-26T18:28:29Z (GMT). No. of bitstreams: 1
texto completo.pdf: 8157414 bytes, checksum: e5c01d282431be7897b90d48b305fcd9 (MD5)
Previous issue date: 1996-09-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho é uma contribuição ao estudo da contaminação, por crômio, em ecossistemas aquáticos fluviais que recebem dejetos resultantes das atividades de indústrias de curtimento de couros (curtumes). Essa problemática decorre da freqüência e necessária utilização de compostos de crômio, visando à melhoria da qualidade do couro. O aspecto bioquímico mais importante e provavelmente mais conhecido do crômio é a reação com as proteínas, como a curtição de couros, que é a transformação do colágeno da pele em couro através do entrelaçamento das protofibrilas do colágeno. No que tange à toxicidade do crômio, esta depende do estado de oxidação em que é lançado no efluente. Existem muitas referências sobre os efeitos cancerígenos do Cr(VI), e outras sobre a possibilidade de íons Cr(V) também o serem; os íons Cr(III), entretanto, não parecem ter, diretamente, implicações tóxicas. Embora nos despejos de curtumes predominem os compostos de crômio trivalente, dependendo de alguns parâmetros característicos do corpo receptor, a oxidação de Cr(III) à Cr(VI), acredita-se poder ser favorecida, colocando em risco a fauna, a flora e a população que utiliza estas águas. A principal preocupação neste trabalho deve-se à possibilidade de despejos de íons Cr(III) que, mesmo não sendo tão nocivos, causarem efeitos maléficos em elevadas concentrações. Foram realizadas análises em compartimentos abióticos como águas, material particulado em suspensão e sedimento e em compartimentos bióticos como vegetação ribeirinha e peixe. A determinação de crômio foi realizada em espectrofotômetro de absorção atômica, em chama N2O-acetileno, utilizando o método de adição-padrão para análise de águas, e curva de calibração para as demais amostras. As localidades estudadas compreenderam: Ipatinga, Matias Barbosa, Dores de Campo, Ressaquinha, Ubá, e Juiz de Fora. Para efeitos comparativos, analisaram-se amostras coletadas em área não-industrializada (Belmiro Braga-MG). Os resultados obtidos confirmaram a contaminação. Em geral, as amostras de vegetação, sedimento e peixe apresentaram maior contaminação. Pela análise em itens da biota, concluiu-se que existe uma transferência de crômio entre os compartimentos dos ecossistemas estudados. Consciente da complexidade do problema, e considerando a importância atual dos estudos ambientais, é necessário que se faça um monitoramento visando gerar dados relevantes para o controle ambiental. / This paper deals with chromium pollution caused by leather manufactories through their pertinent streams. The leather quality improvements by chromium is performed through its reaction with protofibrils of collagen. Toxicity of chromium is a matter of its oxidation-level when discharged into the streams. There are many references about cancerous effects of Cr(VI); also Cr(V) is being considered, quite opposite to Cr(III), which is admitted not to be considerably harmful. On this behalf, analyses were accomplished in abiotic environments (river water, suspended material and sediment), as well as in biotic components (vegetation and fish). The concentrations in the samples were measured by atomic absorption spectrophotometry. Water samples were analysed by standard addition method, while chromium concentrations in the other samples were determined by calibration curves. Localities investigated were Ipatinga, Matias Barbosa, Dores de Campo, Ressaquinha, Ubá e Juiz de Fora. For comparison purposes, samples of a not- industrialized area were also considered. The results attest contamination by leather processing. In general, plants, sediments and fish disclosed precariously high levels. It seems that chromium suffers transport within the components of the ecosystem. Further experiments under controlled conditions are recommended.
|
3 |
"Estudo espectrofotométrico do sistema crômio(III)/azoteto e seu aproveitamento analítico". / "Spectrophotometric study of chromium(III)/azide system and your analytical application".Lourenço, Leandro Maranghetti 06 February 2004 (has links)
Na área de Química, uma das linhas mais tradicionais de pesquisa envolve o estudo de formação de complexos. Estes trabalhos são realizados de modo sistemático em nossos laboratórios, geralmente envolvendo cátions de metais de transição com vários ligantes (haletos, pseudo-haletos e carboxilatos). A intensa coloração desenvolvida pela maioria dessas reações de complexação, entre um metal e um pseudo-haleto, tem motivado o desenvolvimento de novos métodos espectrofotométricos para a determinação de íons em amostras reais. Espera-se que o crômio(III), da mesma forma que outros metais de transição, como o ferro, níquel e cobalto, forme complexos com o pseudo-haleto denominado azida ou azoteto (N3-). Desta forma, dando continuidade a esta linha de pesquisa, este trabalho teve como objetivo otimizar as condições experimentais para o sistema crômio(III)/azoteto. Diversos parâmetros como acidez, concentração de ligante, natureza e concentração de solvente, bem como o efeito da temperatura, foram investigados. Reunidas as melhores condições (otimização), montou-se o método analítico que possibilita a determinação do metal. As condições ideais empregadas foram: concentração analítica de ligante e ácido perclórico de 493 e 12,0 mmol L-1, respectivamente, numa temperatura de 25ºC, em meio aquoso. Para a determinação no ultravioleta, o tempo de espera para cada medida foi de 1 hora, enquanto que na região do visível, foi de apenas 30 minutos. Os máximos de absorção ocorreram em torno de 646, 480 e 287 nm, com coeficientes de absortividade molar médios de 184±1, 157±1 e (1,481±0,008) 104 L mol-1 cm-1, respectivamente. As condições estabelecidas foram promissoras, permitindo uma boa repetitividade nas regiões do visível e ultravioleta. Para o método desenvolvido, os íons mais interferentes na região do visível foram: Fe3+, Co2+ e Cu2+ e, na região do ultravioleta, foram HC8H4O4-, Fe3+, Cu2+ e Hg2+. Por meio de um sistema com duas equações, a determinação simultânea de crômio e ferro mostrou-se possível e com erros dentro dos limites analiticamente aceitáveis. Sem a utilização do sistema de equações, verificou-se ainda a possibilidade de se determinar crômio diretamente, mesmo na presença de ferro, no comprimento de onda de 646,5 nm, com um erro menor que 5%, desde que a concentração de ferro não ultrapasse 4 mg L-1. Aplicações analíticas para o método proposto foram testadas em dois suplementos alimentares contendo crômio. Os resultados foram comparados e mostraram-se concordantes com os da técnica de espectrometria de absorção atômica, para o suplemento contendo crômio quelato. Para o suplemento alimentar contendo picolinato de crômio, houve uma discordância dos resultados, indicando a existência de interferentes da matriz que não puderam ser eliminados. Um teste com uma amostra sintética de crômio mostrou um erro de cerca de 1,0% para o método proposto. Em condições ideais, e com um controle dos interferentes presentes, o método proposto mostra-se preciso, simples e barato. Considerando valores de absorbância entre 0,2 e 0,8 (faixa ideal), pode-se determinar o metal nos intervalos de 1,27 a 5,09 mmol L-1 a 480,5 nm, de 1,09 a 4,35 mmol L-1 a 646,5 nm e, finalmente, entre 0,702 a 2,81 mg L-1 no ultravioleta (287 nm). / In Chemistry, the study of complexes formation is one of the most traditional research lines. These studies are done under systematic manners in our laboratories, usually involving metallic transition cations with several ligands (halides, pseudohalides and carboxylates). The intense coloration developed by the major part of those complexation reactions, between a metal and a pseudohalide, has encouraged the development of new spectrophotometric methods for determination of ions in real samples. Conforming others transition metals, (iron, nickel and cobalt), which form complexes with the pseudohalide azide (N3-), we tried to observe the same behavior to chromium(III). Continuing this research line, this work had as principal objectives optimizes the experimental conditions for the chromium(III)/azide system. Several parameters were investigated as acidity, ligand concentration, nature and solvent concentration, as well as temperature effect for optimization of experimental conditions. Gathering all these conditions, the analytical methods were tested for the metal determination. The ideal conditions employed were: analytical ligand concentration and perchloric acid of 493 and 12.0 mmol L-l respectively, at 25 °C, in aqueous medium. For the studies in the ultraviolet region, the contact time before the measures was one hour, while for studies in the visible band measures were made after 30 minutes. The wavelengths of maximum absorption were encountered at 646, 480 and 287 nm, with molar absorptivity coefficients (mean) of 184±1, 157±1 and (1.481±0,008) 104 L mol-1 cm-1, respectively. The established conditions were promising, allowing a good precision in the visible and ultraviolet region. For the developed method, the more interfering ions on visible band were: Fe3+, Co2+ and Cu2+ and, on the ultraviolet band, were HC8H4O4-, Fe3+, Cu2+ and Hg2+. Through a system of two equations, the simultaneous determination of chromium and iron ions was possible with errors within the tolerance range. Without the simultaneous equations system, it was verified directly the possibility of chromium determination in the presence of iron, at a wavelength of 646.5 nm, with an error smaller than 5%, since the concentration of iron doesnt exceed 4 mg L-l. In this proposed method, analytical applications were tested for two alimentary supplements containing chromium. The results were compared, being concordant with those of atomic absorption technique for the supplement containing chromium chelate, while for the alimentary supplement containing chromium picolinate, the results were in disagreement with the results, indicating the existence of matrix interferences which could not be eliminated. A test with a synthetic sample of chromium had an error of about 1.0% for the proposed method. Under ideal conditions, and with some control of possible interfering, the proposed method can be precise, accurate, simple and cheap. Considering the absorbance values between 0.2 and 0.8 (ideal range), the metal can be determined from 1.27 to 5.09 mmol L-l in 480 nm; 1.09 to 4.35 mmol L-l in 646 nm and, finally, from 0.702 to 2.81 mg L-l at 287 nm (ultraviolet).
|
4 |
Determinação da presença de Bário, Chumbo e Crômio em amostras de água subterrânea coletadas no Aqüífero Bauru / Determination of the presence of Barium, Lead and Crhomium in the groundwater samples colleted in the Aquifer BauruSavazzi, Eduardo Angelino 27 March 2009 (has links)
A ocorrência de elementos químicos em águas subterrâneas tem grande importância em todo mundo devido à diversidade de seus efeitos tóxicos e ampla distribuição no meio ambiente. Entre esses elementos, podem ser citados o bário, chumbo e o crômio, que podem levar a efeitos diversos como neurotoxicidade e carcinogenicidade. O aqüífero Bauru, por ser um aqüífero freático, apresenta vulnerabilidade natural alta, podendo ocorrer contaminação devido à disposição no solo de resíduos contento estas e outras substâncias químicas. Dentro deste contexto, os objetivos deste trabalho foram: validação do método de análise e quantificação de bário, chumbo e o crômio por espectrometria de emissão atômica por plasma indutivamente acoplado ICP OES; e a determinação destes elementos em amostras de água subterrânea coletadas no aqüífero Bauru. Foram avaliados 56 pontos de coletas em 55 municípios na região ocidental do Estado de São Paulo, em duas campanhas distintas, os quais, a maioria apresentou concentrações desses elementos químicos abaixo do preconizado para consumo humano pela Resolução CONAMA n°. 396. Apresentaram valores acima do estabelecido um ponto em relação ao Bário e dez pontos em relação ao Crômio, cujos Valores Máximos Permitidos são, respectivamente, de 0,7mg.L-1Ba e 0,05mg.L-1Cr. / The occurrence of chemical element in groundwater has a great importance in the world because of the diversity of toxic effects and wide distribution in the environment. Between these chemical elements, we can cite barium, lead and chromium that can induce diverse effects such neurotoxicity and carcinogenicity. It has been considered that the aquifer Bauru has high vulnerability. Therefore the contamination may occur due to the presence of these elements in the soil related to a variety of sources. So, the objectives of this study were: the validation of the method of atomic spectrometry by inductively coupled plasma ICP OES; and the determination of these compounds in samples of groundwater collected in aquifer Bauru. We collected samples in 56 sites located in 55 municipalities in the western region of the state of São Paulo. Almost all the samples analyzed were in accordance with the Brazilian law, for drinking water proposes (Resolução CONAMA n° 396) in relation to the elements. Only 11 sites showed values above to the established: one for Barium and ten for Chromium. The threshold Values allowed for these elements are respectively, of 0.7mg.L-1Ba and 0.05mg.L-1Cr.
|
5 |
Docking e análise do modo de ligação de três moléculas pequenas, um benzimidazol e dois compostos de crômio, nos sulcos do DNA 5'-CGCGAATTCGCG-3Reis, Esther Camilo dos [UNESP] 10 April 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:29Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-04-10Bitstream added on 2014-06-13T18:50:41Z : No. of bitstreams: 1
reis_ec_me_bauru.pdf: 1547855 bytes, checksum: c064de6707319508d31999121d801d42 (MD5) / Secretaria de Educação do Estado de São Paulo / Neste trabalho foi estudado o modo de ligação de três moléculas pequenas ao DNA 5'-CGCGAATTCGCG-3', através da simulação computacional e análise em tela gráfica. Verificou-se que é possível utilizar o programa GOLD, baseado em algoritmos genéticos, em estudos envolvendo o DNA, uma vez que até o momento há apenas dois trabalhos publicados na base de dados Scopus (Portal de Periódicos da Capes) onde esta metodologia é utilizada. Também foi verificado que 1vzk, complexo cristalográfico do DNA com 2-(5-{4-[amino (imino)metil]fenil}-2-tienil)-1h-benzimidazol-6-carboximida (DB818), obtido do PDB é uma estrutura representativa para estudos no sulco menor. Foram investigados os modos de ligação dos seguintes ligantes: (a) DB818, obtido a partir da estrutura cristalográfica 1 vzk; (b) DAZJOE; [Cr(1,2-bis(naftilidenoamino)etano)(H2O)2], estrutura obtida do Cambridge Structural Database e (c) CR3NC, [Cr(2,3-bis{[(2-hidroxi-4-dietilamino) (fenil) (metileno)]amino}2-butenodinitrila) (H2O)2], cuja estrutura foi obtida por modelagem molecular, tomando como modelo DAZJOE. Os estudos de docking do DAZJOE em DNA sugerem que seu modo de ligação seria no sulco menor, porém sua interação não se dá com as bases AATTC como no caso do DB818, mas sim entre as bases ATTC. Quando os cálculos de docking foram realizados com a molécula CR3NC, que tem volume maior e mais flexibilidade nas extremidades, observou-se que a mesma posiciona-se no sulco maior. Este resultado está em concordância com dados experimentais disponíveis. Um mecanismo de quebra do DNA é sugerido, não devido à influência do crômio, mas sim devido à presença dos nitrogênios. Observou-se que a influência do metal é menor do que a da molécula complexada ao íon nas interações. / In this work we studied the binding mode of some small molecules in the DNA 5'-CGCGAATTCGCG-3' through computer simulation and analysis in graphical screen. We found that it is possible to use the GOLD program, based on genetic algorithms in studies involving DNA, despite we found only two papers in the database Scopus (CAPES Portal of Journals) where this approach is used. It was also found that 1 vzk, crystallographic complex of the DNA with 2-(5-(a-[amino (imino) methyl] phenil) -2- thienyl)- 1h-benzimidazol-6-carboximide (DB818), obtained from PDB is a representative structure for studies in the minor groove. We investigated the binding mode of the following ligands: a) DB818, obtained from the 1vzk crystallographic structure, (d) DAZJOE, [Cr(1,2-bis(naphthylideneamino) ethane)(H2O)2], structure obtained from Cambridge Structural Database and (c) CR3NC, [Cr((2,3-bis[(2-hydroxy-4phenyl) (diethylamino) (methylene)] 2-amino butenedinitrile)(H2O)2, whose structure was obtained by molecular modeling, taking DAZJOE as model. The DAZJOE docking's studies in DNA suggest that its binding mode would be in the minor groove, but their interaction is not given with the bases AATTC as for the DB818, but between the bases ATTC. When the docking calculations were performed with CR3NC molecule, which has larger volume and more flexibility in the extremities, we observed that in take place in major groove. This result is in agreement with experimental data available. It is suggested a DNA break mechanism, but not due to the influence of chromium, but the nitrogens. It was observed that the influence of the metal is lower than the ionophore in interactions.
|
6 |
Resposta imune humoral em bovinos da raça nelore vacinados contra a raiva e suplementados com crômio orgânicoGiometti, José [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:12Z (GMT). No. of bitstreams: 0
Previous issue date: 2004Bitstream added on 2014-06-13T21:02:24Z : No. of bitstreams: 1
giometti_j_dr_botfmvz.pdf: 479475 bytes, checksum: 5a083a25e321335dd33e91917eeffa20 (MD5) / Universidade Estadual Paulista (UNESP) / With the objective of to evaluate the effect of the addition of orgainc chromium in the humoral immune response against rabies, five Neloreþs bovine breed groups with 15 animals each, were supplementeds with chromium yeast being the group GC (control), GV (vaccinated and without chromium), GV+8,5 (vaccinated + 8,5 ppm of chromium), GV+17 (vaccinated + 17 ppm of chromium) and GV+34 (vaccinated +34 ppm of chromium). Serum samples of this animals were analyseds with serum neutralization test (SN) in albines mices in the days 30,60 and 90 pos -vaccination. Simultaneously, serum concentrations of the chromium were determinated for analysis with spectrophotometer of atomic absorption in graphite oven and analysis of the cortisol was achieved through of the radioimmunoassay.These results allows to conclude that the animals of the group GV+34 have persistence of the protector's antibody titulation anti rabies until 90 days pos- vaccination. This response does not dependt of the cortisol levels, since the chromium donþt show to be effective to decrease its levels.
|
7 |
Propriedades espectroscópicas de sílica contendo crômioMartines, Marco Antonio Utrera [UNESP] January 1997 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:08Z (GMT). No. of bitstreams: 0
Previous issue date: 1997Bitstream added on 2014-06-13T20:45:54Z : No. of bitstreams: 1
martines_mau_dr_araiq.pdf: 2947884 bytes, checksum: 72629200eaa3a20a5b20f28125019cc8 (MD5) / Sílica contendo crômio faz parte de uma classe importante de materiais devido às aplicações como catalisador de polimerização e de oxidação, fibras ópticas, laseres e preparação de pigmentos. Este trabalho está dividido em duas partes. A primeira refere-se ao gel úmido e seco de sílica contendo crômio. Os géis foram preparados fazendo-se a mistura das soluções de silicato de sódio solúvel (vidrolíquido) e de soluções aquosas de nitrato de crômio em pH 4 ou 9 previamente ajustado, ou em 4 após a mistura das soluções. O gel foi caracterizado por espectroscopia eletrônica de absorção no ultravioleta -visível e por microscopia eletrônica de transmissão. A morfologia dos géis de sílica e de sílica contendo crômio é dependente do valor de pH e da ordem de mistura dos reagentes. Este efeito é atribuído às espécies poliméricas do crômio diferenciadas presentes na solução que controlam a forma da partícula. Partículas esféricas podem ser obtidas pelo colapso de microgel com alto grau de ligação cruzada. A outra parte do trabalho consiste na preparação de sílica contendo crômio por dois métodos: aquecimento convencional e banho de ultra-som nas temperaturas de 50 e 80oC. O gel obtido foi tratado por extrações com soluções ácidas, extrações com água e diálise, e seco em forno de microondas. As amostras de sílica/crômio em pó foram submetidas ao tratamento térmico em temperaturas de 200 a 1400oC, com intervalos de 200oC, sob atmosfera... / Chromium-containing silica belongs to an important class of materials having technological applications such as polymerization and oxidation catalyses, lasers, pigments and optical fibers. The chromium-containing silica and pure silica gels were obtained by mixing solutions of soluble sodium silicate (water glass) and chromium nitrate with adjusted pH 4 or 9 previously. Other method to prepare the gels was carried out by mixing water glass and chromium nitrate solutions and then the pH 4. The gel was characterized by ultraviolet-visible spectroscopy and transmission electron microscopic. The gel morphology is dependent on the pH value and the order of mixture of reagents. This effect is due to the nature of polymeric shape of chromium species in solution. Spherical particles can be obtained from microgel collapsing with high degree of cross linking . The second part of this work deals with powders obtained from gels. The chromium-containing silica and silica powders were obtained from gel by two methods: i) conventional heating at temperatures of 80 and 50oC and ii) sonication and heating at 80 and 50oC. The resultant colloidal silica was treated by continuous extraction acid solution in followed by extraction in distilled water and then dialyzed against distilled water and dried in microwave oven. The samples were...(Complete abstract, click electronic access below)
|
8 |
"Estudo espectrofotométrico do sistema crômio(III)/azoteto e seu aproveitamento analítico". / "Spectrophotometric study of chromium(III)/azide system and your analytical application".Leandro Maranghetti Lourenço 06 February 2004 (has links)
Na área de Química, uma das linhas mais tradicionais de pesquisa envolve o estudo de formação de complexos. Estes trabalhos são realizados de modo sistemático em nossos laboratórios, geralmente envolvendo cátions de metais de transição com vários ligantes (haletos, pseudo-haletos e carboxilatos). A intensa coloração desenvolvida pela maioria dessas reações de complexação, entre um metal e um pseudo-haleto, tem motivado o desenvolvimento de novos métodos espectrofotométricos para a determinação de íons em amostras reais. Espera-se que o crômio(III), da mesma forma que outros metais de transição, como o ferro, níquel e cobalto, forme complexos com o pseudo-haleto denominado azida ou azoteto (N3-). Desta forma, dando continuidade a esta linha de pesquisa, este trabalho teve como objetivo otimizar as condições experimentais para o sistema crômio(III)/azoteto. Diversos parâmetros como acidez, concentração de ligante, natureza e concentração de solvente, bem como o efeito da temperatura, foram investigados. Reunidas as melhores condições (otimização), montou-se o método analítico que possibilita a determinação do metal. As condições ideais empregadas foram: concentração analítica de ligante e ácido perclórico de 493 e 12,0 mmol L-1, respectivamente, numa temperatura de 25ºC, em meio aquoso. Para a determinação no ultravioleta, o tempo de espera para cada medida foi de 1 hora, enquanto que na região do visível, foi de apenas 30 minutos. Os máximos de absorção ocorreram em torno de 646, 480 e 287 nm, com coeficientes de absortividade molar médios de 184±1, 157±1 e (1,481±0,008) 104 L mol-1 cm-1, respectivamente. As condições estabelecidas foram promissoras, permitindo uma boa repetitividade nas regiões do visível e ultravioleta. Para o método desenvolvido, os íons mais interferentes na região do visível foram: Fe3+, Co2+ e Cu2+ e, na região do ultravioleta, foram HC8H4O4-, Fe3+, Cu2+ e Hg2+. Por meio de um sistema com duas equações, a determinação simultânea de crômio e ferro mostrou-se possível e com erros dentro dos limites analiticamente aceitáveis. Sem a utilização do sistema de equações, verificou-se ainda a possibilidade de se determinar crômio diretamente, mesmo na presença de ferro, no comprimento de onda de 646,5 nm, com um erro menor que 5%, desde que a concentração de ferro não ultrapasse 4 mg L-1. Aplicações analíticas para o método proposto foram testadas em dois suplementos alimentares contendo crômio. Os resultados foram comparados e mostraram-se concordantes com os da técnica de espectrometria de absorção atômica, para o suplemento contendo crômio quelato. Para o suplemento alimentar contendo picolinato de crômio, houve uma discordância dos resultados, indicando a existência de interferentes da matriz que não puderam ser eliminados. Um teste com uma amostra sintética de crômio mostrou um erro de cerca de 1,0% para o método proposto. Em condições ideais, e com um controle dos interferentes presentes, o método proposto mostra-se preciso, simples e barato. Considerando valores de absorbância entre 0,2 e 0,8 (faixa ideal), pode-se determinar o metal nos intervalos de 1,27 a 5,09 mmol L-1 a 480,5 nm, de 1,09 a 4,35 mmol L-1 a 646,5 nm e, finalmente, entre 0,702 a 2,81 mg L-1 no ultravioleta (287 nm). / In Chemistry, the study of complexes formation is one of the most traditional research lines. These studies are done under systematic manners in our laboratories, usually involving metallic transition cations with several ligands (halides, pseudohalides and carboxylates). The intense coloration developed by the major part of those complexation reactions, between a metal and a pseudohalide, has encouraged the development of new spectrophotometric methods for determination of ions in real samples. Conforming others transition metals, (iron, nickel and cobalt), which form complexes with the pseudohalide azide (N3-), we tried to observe the same behavior to chromium(III). Continuing this research line, this work had as principal objectives optimizes the experimental conditions for the chromium(III)/azide system. Several parameters were investigated as acidity, ligand concentration, nature and solvent concentration, as well as temperature effect for optimization of experimental conditions. Gathering all these conditions, the analytical methods were tested for the metal determination. The ideal conditions employed were: analytical ligand concentration and perchloric acid of 493 and 12.0 mmol L-l respectively, at 25 °C, in aqueous medium. For the studies in the ultraviolet region, the contact time before the measures was one hour, while for studies in the visible band measures were made after 30 minutes. The wavelengths of maximum absorption were encountered at 646, 480 and 287 nm, with molar absorptivity coefficients (mean) of 184±1, 157±1 and (1.481±0,008) 104 L mol-1 cm-1, respectively. The established conditions were promising, allowing a good precision in the visible and ultraviolet region. For the developed method, the more interfering ions on visible band were: Fe3+, Co2+ and Cu2+ and, on the ultraviolet band, were HC8H4O4-, Fe3+, Cu2+ and Hg2+. Through a system of two equations, the simultaneous determination of chromium and iron ions was possible with errors within the tolerance range. Without the simultaneous equations system, it was verified directly the possibility of chromium determination in the presence of iron, at a wavelength of 646.5 nm, with an error smaller than 5%, since the concentration of iron doesnt exceed 4 mg L-l. In this proposed method, analytical applications were tested for two alimentary supplements containing chromium. The results were compared, being concordant with those of atomic absorption technique for the supplement containing chromium chelate, while for the alimentary supplement containing chromium picolinate, the results were in disagreement with the results, indicating the existence of matrix interferences which could not be eliminated. A test with a synthetic sample of chromium had an error of about 1.0% for the proposed method. Under ideal conditions, and with some control of possible interfering, the proposed method can be precise, accurate, simple and cheap. Considering the absorbance values between 0.2 and 0.8 (ideal range), the metal can be determined from 1.27 to 5.09 mmol L-l in 480 nm; 1.09 to 4.35 mmol L-l in 646 nm and, finally, from 0.702 to 2.81 mg L-l at 287 nm (ultraviolet).
|
9 |
Determinação da presença de Bário, Chumbo e Crômio em amostras de água subterrânea coletadas no Aqüífero Bauru / Determination of the presence of Barium, Lead and Crhomium in the groundwater samples colleted in the Aquifer BauruEduardo Angelino Savazzi 27 March 2009 (has links)
A ocorrência de elementos químicos em águas subterrâneas tem grande importância em todo mundo devido à diversidade de seus efeitos tóxicos e ampla distribuição no meio ambiente. Entre esses elementos, podem ser citados o bário, chumbo e o crômio, que podem levar a efeitos diversos como neurotoxicidade e carcinogenicidade. O aqüífero Bauru, por ser um aqüífero freático, apresenta vulnerabilidade natural alta, podendo ocorrer contaminação devido à disposição no solo de resíduos contento estas e outras substâncias químicas. Dentro deste contexto, os objetivos deste trabalho foram: validação do método de análise e quantificação de bário, chumbo e o crômio por espectrometria de emissão atômica por plasma indutivamente acoplado ICP OES; e a determinação destes elementos em amostras de água subterrânea coletadas no aqüífero Bauru. Foram avaliados 56 pontos de coletas em 55 municípios na região ocidental do Estado de São Paulo, em duas campanhas distintas, os quais, a maioria apresentou concentrações desses elementos químicos abaixo do preconizado para consumo humano pela Resolução CONAMA n°. 396. Apresentaram valores acima do estabelecido um ponto em relação ao Bário e dez pontos em relação ao Crômio, cujos Valores Máximos Permitidos são, respectivamente, de 0,7mg.L-1Ba e 0,05mg.L-1Cr. / The occurrence of chemical element in groundwater has a great importance in the world because of the diversity of toxic effects and wide distribution in the environment. Between these chemical elements, we can cite barium, lead and chromium that can induce diverse effects such neurotoxicity and carcinogenicity. It has been considered that the aquifer Bauru has high vulnerability. Therefore the contamination may occur due to the presence of these elements in the soil related to a variety of sources. So, the objectives of this study were: the validation of the method of atomic spectrometry by inductively coupled plasma ICP OES; and the determination of these compounds in samples of groundwater collected in aquifer Bauru. We collected samples in 56 sites located in 55 municipalities in the western region of the state of São Paulo. Almost all the samples analyzed were in accordance with the Brazilian law, for drinking water proposes (Resolução CONAMA n° 396) in relation to the elements. Only 11 sites showed values above to the established: one for Barium and ten for Chromium. The threshold Values allowed for these elements are respectively, of 0.7mg.L-1Ba and 0.05mg.L-1Cr.
|
10 |
\"Avaliação do método das médias móveis no tratamento de sinais de absorção atômica de cádmio, chumbo e crômio obtidos por atomização eletrotérmica em filamento de tungstênio\" / \"Evaluation of the moving averages in the treatment of cadmium, lead and chromium atomic absorption signals from electrothermal atomization\"Leme, Flavio de Oliveira 20 December 2006 (has links)
Este trabalho teve como objetivo avaliar o uso do método das médias móveis na atomização de cádmio, crômio e chumbo utilizando filamento de tungstênio de 150 W (OSRAM) como atomizador eletrotérmico. Realizou-se um estudo sistemático da influência da altura de observação, da temperatura e taxa de aquecimento na atomização dos analitos e a viabilidade do uso do método das médias móveis no tratamento dos sinais transientes gerados na atomização. O estudo da influência da altura de observação foi realizado posicionado-se o filamento no centro (0 mm), 1 e 2 mm abaixo do feixe de radiação. A influência da temperatura e da taxa de aquecimento foi estudada utilizando temperaturas na etapa de atomização entre 1890 e 2780 °C. O método das médias móveis foi aplicado aos sinais transientes gerados na atomização, com o filamento posicionado no centro (0 mm), 1 e 2 mm e com temperatura de atomização entre 2060 e 2780 °C, utilizando fatores 0, 3, 5, 7 e 9. No estudo da temperatura e da taxa de aquecimento foram aplicadas ddps no software de controle na etapa de atomização entre 4 e 12 V. As soluções usadas no desenvolvimento deste trabalho foram preparadas em meio 0,1 % v/v HNO3. Utilizou-se como gás de proteção a mistura de 90% Ar+10 % H2. Para o cádmio, recomenda-se a utilização da altura de observação de 1 mm, para o chumbo recomenda-se 0 mm e para o crômio a altura recomendada é a de 2 mm. Os estudos comprovaram a dependência dos sinais de absorção atômica em altura de pico com a temperatura e a taxa de aquecimento. O cádmio foi o analito em que a taxa de aquecimento foi a menos crítica para a atomização, enquanto que o crômio foi o mais afetado pela variação da taxa de aquecimento. Não foi observada diferença significativa entre os sinais de cádmio com alturas de observação de 0 e 1 mm. Para o chumbo, a diferença entre os sinais com altura de observação de 0 e 1 mm foi constante em todas as taxas de aquecimento estudadas. A 2 mm a diferença entre os sinais aumentou com o aumento da taxa de aquecimento. Para o crômio, não ocorreu uma diferença significativa entre os sinais nas alturas de 1 e 2 mm com atomização até 2180 °C. Nos três analitos a sensibilidade aumentou com o aumento da taxa de aquecimento. O método das médias móveis permitiu a diminuição da variação dos sinais transientes do branco e do ruído. Para o cádmio, não ocorreu uma melhora no limite de detecção do método com a aplicação das médias móveis em nenhuma condição. Para o chumbo e crômio, ocorreu uma melhora no limite de detecção do método nas alturas de observação de 0 e 1 mm. O limite de detecção instrumental apresentou uma melhora significativa para os três elementos em todas as condições estudadas. / The aim of this paper was to evaluate the use of moving averages of cadmium, chromium and lead transient atomic absorption signals generated by 150 W (OSRAM) tungsten coil electrothermal atomizer. A systematic study dealing with the influence of observation height, temperature and heating rate on atomization was carried through in order to demonstrate the viability of moving averages in the treatment of the transient signals during the atomization step. The influence of observation height was carried out with the tungsten coil in the center (0 mm), at 1 and 2 mm below the radiation beam. The influence of atomization temperature and heating rate were evaluated between 1890 °C (3.3 K.ms-1) and 2780 °C (9,3 K.ms-1). The transient moving averages were obtained by using factors 0, 3, 5, 7 and 9, with the tungsten coil in the center (0 mm), 1 and 2 mm and with atomization between 2060 and 2780 °C. For obtaining different temperatures and heating rates, an appropriate power supply was used by applying 4 to 12 V (40 to 120 W) to the atomizer during atomization and a mixture 90% Ar+10% H2 was used as purge/atomization gas. Blanks and reference solutions were prepared in 0,1% v/v HNO3. Best results for cadmium were obtained at 1 mm. For lead it is recommended 0 mm and for chromium 2 mm. The studies had proven the dependence of peak height absorbance signals with temperature and heating rate. Cadmium was the analyte where the heating rate was to less critical for the atomization, whereas chromium was affected by the variation of the heating rate. Significant differences were not observed between cadmium signals with observation heights of 0 and 1 mm. For lead, the difference between the absorbance signals with observation heights of 0 and 1 mm were constant in all tested heating rates. At 2 mm the difference between signals increased by increasing the heating rates. For chromium, a significant difference was not noticed between peak height absorbance signals at 1 and 2 mm with up to 2180 °C. As expected, sensitivity increased for all three analytes by increasing the heating rate. The moving average is a powerful mathematical treatment for minimizing unpredictable fluctuations of the base line during the chosen time interval for measuring the transient absorbance signals. With the exception of Cd, where no improvements on the method detection limit were noticed, the application of the moving average for the lead and chromium showed 3 to 4 fold improvement in the LDmet at 0 and 1 mm observation heights, respectively. The LDinstr presented a significant improvement (3 to 6 fold) for the three analytes in all studied conditions.
|
Page generated in 0.0621 seconds