• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • Tagged with
  • 23
  • 23
  • 23
  • 23
  • 23
  • 21
  • 15
  • 14
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Influ?ncia dos cimentos resinosos na deflex?o de c?spides de pr?-molares tratados endodonticamente e restaurados com inlays em resina composta

Rosa, Helen Cristina Vieira da 01 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:19Z (GMT). No. of bitstreams: 1 Helen Cristina Vieira da Rosa.pdf: 575465 bytes, checksum: 907bc1dd4c8788ff1bcb0479b1249fc5 (MD5) Previous issue date: 2013-03-01 / The aim of this study was to evaluate the influence of different resin cements in the cuspal deflection of teeth with endodontic treatment. Sixty superior premolars were randomly divided into five (n=12) groups: 1 sound teeth; 2 cavity; 3 - Rely X ARC; 4 RelyX U100; 5 SeT. The teeth from groups 2, 3, 4 and 5 received a MOD preparation and endodontic treatment. Impressions were made with vinyl polysiloxane and poured using type IV die stone in groups 3, 4 and 5. Inlays with Z250 composite resin were built over each cast and luted with the resin cements according manufacturer s instructions. The specimens were stored in distilled water at 37o C for 72 hours. The specimens were positioned in a universal testing machine and a load of 200 N was applied in the oclusal region with a steel rod with 8 mm in diameter. The cusp deflection was measured after and before the load by means a micrometer that contacted the buccal and palatine faces. After 24 h, the cuspal deflection was measured again using a load of 300 N. According to ANOVA and Tukey s test ( α= 0.05), for both occlusal loads, the sound teeth presented the lowest mean cuspal deflection, differing statistically from the other groups. Intermediate values were obtained in RelyX ARC group and RelyX U100 group, differing statistically between them. The highest cuspal deflections were obtained in SeT group and cavity group, not differing statistically between them. According to the Student t-test, there was a statistically significant difference among the 200 N and 300 N occlusal loads for the cavity group (p = 0.002), RelyX U100 group (p = 0.000), and SeT group (p = 0.004). There was no statistical difference for the sound teeth group (p = 0.389), and RelyX ARC group (p = 0.188). The inlays luted with RelyX ARC obtained lower cuspal deflection in comparison with the self-adhesive resin cements; RelyX U100 showed lower cuspal deflection than SeT. / O objetivo desse trabalho foi avaliar a influ?ncia de diferentes cimentos resinosos na deflex?o de c?spides de dentes com tratamento endod?ntico. Sessenta pr?-molares superiores foram divididos aleatoriamente em cinco grupos (n=12): 1 - h?gidos; 2 - cavidades; 3 - RelyX ARC; 4 - RelyX U100; 5 - SeT. Os dentes dos grupos 2, 3, 4 e 5 receberam preparos MOD e tratamento endod?ntico. Os dentes dos grupos 3, 4 e 5 foram moldados com silicone por adi??o, seguido de vazamento de gesso tipo IV. Sobre cada modelo foi confeccionada uma restaura??o inlay em resina composta Z250. As restaura??es foram cimentadas com os cimentos resinosos, de acordo com cada grupo experimental, seguindo as instru??es dos fabricantes. Os corpos de prova foram armazenados em ?gua destilada a 37? C por 72 horas. Em m?quina de ensaio universal, uma carga de 200 N foi aplicada na regi?o oclusal com esfera de a?o de 8 mm de di?metro e, com o aux?lio de um micr?metro posicionado nas faces vestibular e palatina, a deflex?o das c?spides foi medida antes e ap?s a carga. Ap?s 24 horas, foi realizado o mesmo procedimento aplicando uma carga de 300 N na regi?o oclusal. De acordo com ANOVA e teste de Tukey (α=0,05), para ambas as cargas, o menor valor m?dio de deflex?o de c?spides ocorreu no grupo dente h?gido, diferindo estatisticamente dos demais grupos. O segundo menor valor foi obtido para o grupo RelyX ARC, seguido do grupo RelyX U100, os quais diferiram estatisticamente entre si. As maiores m?dias de deflex?o de c?spides foram obtidas com o grupo SeT e o grupo dente com cavidade, n?o diferindo estatisticamente entre si. De acordo com o teste t-student para amostras pareadas (α=0,05), houve diferen?a estat?stica para a m?dia de deflex?o de c?spides entre as cargas de 200 N e 300 N para o grupo cavidade (p = 0,002), o grupo RelyX U100 (p = 0,000), e o grupo SeT (p = 0,004). N?o houve diferen?a estat?stica para o grupo dente h?gido (p = 0,389) e para o grupo RelyX ARC (p = 0,188). As inlays fixadas com RelyX ARC tiveram deflex?o de c?spides inferior ? obtida com os cimentos resinosos autoadesivos, sendo que o RelyX U100 proporcionou menor deflex?o de c?spides em rela??o ao SeT.
12

Avalia??o da aplica??o de uma solu??o experimental inibidora de metaloproteinase na resist?ncia de uni?o mediata de sistemas adesivos

Melara, Rafael 21 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:20Z (GMT). No. of bitstreams: 1 447186.pdf: 2766501 bytes, checksum: a394900abd9b1fe55a4a5e1b39342bad (MD5) Previous issue date: 2013-03-21 / This study aimed to evaluate, in vitro, the mediate microtensile bond strength- μTBS (12 months) of adhesive systems Adper Scotchbond SE / 3M/ESPE (Adper SE) and Adper Scotchbond Multi-Purpose / 3M/ESPE (Adper SMP) to sound dentin surface, treated or not with an experimental acid solution inhibitor of metalloproteinases (MMPs), as well as the predominant pattern of failure by fractography; and evaluate, in vitro, the inhibition of gelatinolytic activity by an experimental acid solution for dentin surface etching containing tetracycline compared with an experimental solution containing tetracycline. For mediate μTBS evaluation, in Adper SE Control and Adper SMP Control groups, the adhesive system was applied according to the manufacturer's instructions. In Adper SE Experimental group was applied the experimental solution prior to the adhesive system, and in the Adper Experimental SMP group, the etching with 37% phosphoric acid was replaced by applying the experimental solution. After applying the adhesive systems, the teeth were prepared for μTBS test, and the sticks were stored in an oven at 37?C. After 12 months μTBS test was realized and the sticks were evaluated by SEM. For enzymatic activity evaluation, saliva samples were collected from healthy donors, centrifuged and the supernatant was used by technique of zymography. This technique was based on the use of electrophoresis, in which a protein substrate (gelatin) was co-polymerized with acrylamide. The enzymes were separated under non-reducing conditions, renatured and then incubated in suitable buffer, based on the association between the substrate digestion and verification of the molecular weight of proteases. To quantify the relative inhibition by the two solutions was used the Image J software (NIH, Bethesda, MD, USA) and compared with the control. For mediate μTBS evaluation, according to the Tukey test (α = 0.05), no difference between the control and experimental groups was found for each adhesive system. The predominant pattern of failure for the system Adper SE was cohesive in composite while for Adper SMP was cohesive in hybrid layer. In the enzymatic activity evaluation, the enzymes were characterized as matrix metalloproteinases, because its expression was inhibited by EDTA (a known inhibitor of MMPs), while NEM (an inhibitor of serine proteases) had no effect on enzymatic activity. The MMP identified in the study, was characterized as MMP-2, with a molecular weight of 62KDa. The experimental acid solution presented an inhibition of the gelatinolytic activity of 93.66% (concentration 0.05%) and 58.58% (0.01% concentration), while the experimental solution had a percentage inhibition of 31.28% and 6.83%, respectively. Based on these results we conclude that after 12 months of storage, the adhesive system Adper SE showed better performance that Adper SMP in the microtensile bond strength test, also seeming to be more effective in maintaining the integrity of the adhesive interface, under fractographic analysis; and that the experimental acid solution for dentin surface etching was capable of almost completely inhibits the enzymatic activity of MMP-2 in a dose dependent manner. / Este estudo teve por objetivo avaliar, in vitro, a resist?ncia de uni?o ? microtra??o (RUM) mediata (12 meses) dos sistemas adesivos Adper Scotchbond SE / 3M/ESPE (Adper SE) e Adper Scotchbond Multi-Uso / 3M/ESPE (Adper SMP) ? superf?cie dentin?ria sadia, tratada ou n?o com uma solu??o ?cida experimental inibidora de metaloproteinases (MMPs), bem como o padr?o predominante de falha por fractografia; e avaliar, in vitro, a inibi??o da atividade gelatinol?tica por uma solu??o ?cida experimental para condicionamento de superf?cie dentin?ria contendo tetraciclina em compara??o com uma solu??o experimental contendo tetraciclina. Para avalia??o da RUM mediata, nos grupos Adper SE Controle e Adper SMP Controle, o sistema adesivo foi aplicado de acordo com as instru??es do fabricante. No grupo Adper SE Experimental foi aplicada a solu??o experimental previamente ao sistema adesivo, e no grupo Adper SMP Experimental, o condicionamento com ?cido fosf?rico a 37% foi substitu?do pela aplica??o da solu??o experimental. Ap?s a aplica??o dos sistemas adesivos, os dentes foram preparados para o teste de RUM, e os palitos obtidos foram armazenados em estufa a 37oC. Ap?s 12 meses, foi realizado o teste RUM e os palitos foram avaliados em MEV. Para avalia??o da atividade enzim?tica, amostras salivares foram coletadas de doadores saud?veis, centrifugadas e o sobrenadante foi usado atrav?s da t?cnica zimogr?fica. Esta t?cnica baseou-se no uso da eletroforese, no qual um substrato proteico (gelatina) foi co-polimerizado com acrilamida. As enzimas foram separadas sob condi??es n?o redutoras, renaturadas e ent?o incubadas em tamp?o adequado, baseando-se na associa??o entre digest?o do substrato e verifica??o do peso molecular das proteases. Para quantificar a inibi??o relativa pelas duas solu??es foi usado o programa Image J (NIH, Bethesda, MD, USA) e comparadas com o controle. Em rela??o ? RUM mediata, de acordo com o teste de Tukey (α=0.05), n?o houve diferen?a entre os grupos controle e experimental para cada sistema adesivo. O padr?o predominante de falha para o sistema adesivo Adper SE foi coesiva em resina composta enquanto que para o Adper SMP foi coesiva em camada h?brida. Na an?lise zimogr?fica, as enzimas foram caracterizadas como metaloproteinases da matriz, pois a sua express?o foi inibida pelo EDTA (um conhecido inibidor de MMPs), enquanto o NEM (um inibidor de proteases serinas) n?o teve nenhum efeito sobre a atividade enzim?tica. A MMP identificada no estudo, foi caracterizada como MMP-2, apresentando um peso molecular de 62KDa. A solu??o ?cida experimental apresentou um percentual de inibi??o da atividade gelatinol?tica de 93.66% (concentra??o de 0.05%) e de 58.58% (concentra??o de 0.01%), enquanto que a solu??o experimental teve um percentual de inibi??o de 31.28% e 6.83%, respectivamente. Com base nos resultados encontrados ? poss?vel concluir que ap?s 12 meses de armazenagem, o sistema adesivo Adper SE mostrou desempenho superior ao Adper SMP no teste de RUM, parecendo tamb?m ser mais efetivo na manuten??o da integridade da interface adesiva, sob an?lise fractogr?fica; e que a solu??o ?cida experimental condicionadora de superf?cie dentin?ria foi capaz de inibir quase completamente a atividade enzim?tica da MMP-2, de uma maneira dose dependente.
13

Efeito da vibra??o s?nica e ultrass?nica em um adesivo autocondicionante e de frasco ?nico na resist?ncia de uni?o em dentina

Cavazzola, Fernanda de C?ssia Mortari 11 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:22Z (GMT). No. of bitstreams: 1 447882.pdf: 1769645 bytes, checksum: 707e21b20055331c157549faf714a8c0 (MD5) Previous issue date: 2013-03-11 / Purpose: Investigate the influence of bonding systems application activated through a sonic and ultrasonic vibration and a sonic prototype on micro-tensile bond strength in dentin. Materials and Methods: Twenty-four extracted caries-free intact human molar teeth were embedded in a self-cured acrylic resin. The enamel was removed, using wet 220-, and 600-grit abrasive papers. Each adhesive system (self-etching primer and a single bottle total etch) was applied according to the manufacturer's instructions. Then, the groups were classified according to the type and method of application of bonding systems. After the adhesive technique, resin composite was condensed and light-cured for 20s. Afterwards, all specimens were completely included in a self-cured acrylic resin to stabilize the restorative material and the adhesive interface for the serial sections in a cutting machine. These cylinders were stored in distilled water at room temperature 37?C for 24h. The specimens were stressed in the interface between the composite and the dental surface until fracture occurred. The values were recorded in MPa, and submitted to statistical analysis. Data were submitted to Kolmogorov-Smirnov normality test. Two-way ANOVA and Tukey s Test for pairwise multiple comparisons were used (p<0.05). The failure modes were recorded in percentages.Results: The micro tensile bond strengths with sonic vibration were higher than the other groups, showing statistically significant differences. The sonic, ultrasonic and prototype group had more cohesive failure in resin compared to the control group, which had more cohesive failures of the hybrid layer. Conclusion: The application with a sonic vibration is an effective method for the optimization of bond strength in dentin / Objetivo: Verificar se a aplica??o dos sistemas adesivos, por meio da vibra??o do aparelho s?nico, ultrass?nico e de um prot?tipo s?nico aumenta a resist?ncia de uni?o em dentina. A hip?tese experimental ? que a resist?ncia de uni?o nos sistemas adesivos Adper Single Bond 2 e Clearfill SE Bond ? similar tanto nos grupos controle quanto nos grupos que receberem os diferentes tratamentos. Materiais e M?todo: Foram utilizados 24 terceiros molares h?gidos, onde foi realizada a remo??o do esmalte preparando uma superf?cie dentin?ria lisa. Os dentes foram divididos aleatoriamente em 8 grupos, onde cada sistema adesivo foi aplicado de acordo com as recomenda??es do fabricante (aplica??o din?mica manual) e com a vibra??o de aparelho s?nico , ultrass?nico e por um prot?tipo s?nico. Ap?s a t?cnica adesiva, foi aplicada resina charisma A2. As amostras foram inclu?das em resina acr?lica autopolimeriz?vel, preparando um cilindro para os cortes seriados. Estes foram armazenados em ?gua destilada em uma estufa de cultura a 37?C por 24 horas. Ap?s, confeccionou-se os corpos de prova em forma de barra para o ensaio de resist?ncia de uni?o por microtra??o. Os dados obtidos foram submetidos ao teste Kolmogorov-Smirnov para verifica??o de normalidade.A seguir, foram comparados com ANOVA de duas vias e teste de Tukey (p=0,05). A an?lise da fractografia foi realizada porcentualmente. Resultados: A resist?ncia de uni?o do grupo que recebeu a vibra??o s?nica foi maior, apresentando diferen?as estatisticamente significativas, em ambos os sistemas adesivos, comparada com aplica??o din?mica manual e os grupos que receberam tratamento ultrass?nico e do prot?tipo s?nico. Na an?lise fractografia observa-se que os grupos que receberam tratamento s?nico, ultrass?nico e do prot?tipo tiveram maior falha coesiva em resina em rela??o ao grupo controle, que obteve maiores falhas coesivas de camada h?brida. Conclus?o: A utiliza??o da aplica??o s?nica, ? um m?todo eficaz para a otimiza??o da resist?ncia de uni?o em dentina
14

Avalia??o in vitro da rugosidade superficial e manuten??o dos selantes de superf?cies para resinas compostas submetidos ? escova??o

Bonatto, Fernanda 01 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:24Z (GMT). No. of bitstreams: 1 448373.pdf: 984719 bytes, checksum: e51e892e5e4e07ff9dd9d9321a1c3b79 (MD5) Previous issue date: 2013-03-01 / Objectives : 1) to evaluate the roughness of three surface sealants applied on a composite resin when subjected to simulated toothbrushing for different periods, 2) to evaluate, with the aid of scanning electron microscopy, the presence of surface sealants after simulated toothbrushing; 3) evaluating whether the type of dentifrice may shorten the life of the sealing surface. Materials and Methods : One hundred and eight bodies of the specimens were fabricated with resin Amelogen Plus, divided into 6 groups (n = 18) according to the type of surface sealant (Fortify (F), BisCover LV (B) and Permaseal (P)) and toothpaste (Colgate Total 12 Clean Mint (CT) and Colgate Total Professional Whitening 12 (PW)). The samples were subjected to brushing cycles, simulating periods of 6 months, 12 months, 18 months and 24 months. After each period, the samples had a surface roughness measured. An additional group of 48 samples was conducted for SEM analysis. The results were analyzed by ANOVA with three fixed factors (sealants, time and toothpaste) and Tukey's test (&#945; = 5%). Results : BisCover had the lowest average surface roughness (0.06 &#956;m) compared with sealants Fortify (0.09 &#956;m) and Permaseal (0.08 &#956;m), which were not statistically different. The Fortify on 12 months of brushing, had the highest average roughness (0.13 &#956;m). The average roughness for the dentifrice CT was lower (0.07 &#956;m), compared to the PW (0.08 &#956;m) and was statistically different. The roughness increased up to 12 months of simulated brushing (0.04 &#956;m, 0.08 &#956;m and 0.11 &#956;m), decreasing at the 18th month (0.08 &#956;m) up to 24 months of brushing (0.07 &#956;m). Conclusions : The sealant Fortify had the highest average roughness in 12 months of simulated toothbrushing, and the lowest roughness values were obtained by BisCover. Through SEM, it was observed that none of the seals used in the study was completely removed from the resin by 24 months of brushing. / Objetivos : 1) avaliar a rugosidade de tr?s selantes de superf?cie aplicados sobre uma resina composta quando submetidos ? escova??o simulada por diferentes per?odos; 2) avaliar, com aux?lio da microscopia eletr?nica de varredura, a presen?a dos selantes de superf?cie ap?s escova??o simulada; 3) avaliar se o tipo de dentifr?cio pode diminuir o tempo de vida ?til dos selantes de superf?cie. Materiais e M?todos : Cento e oito corpos-de-prova foram confeccionados com resina Amelogen Plus, divididos em 6 grupos (n=18) conforme o tipo de selante de superf?cie (Fortify (F), BisCover LV (B) e Permaseal (P)) e dentifr?cios (Colgate total 12 Clean Mint (CT) e Colgate total 12 Professional Whitening (PW)). As amostras foram submetidas a ciclos de escova??o, simulando per?odos de 6 meses, 12 meses, 18 meses e 24 meses. Ap?s cada per?odo, as amostras tiveram a rugosidade de superf?cie mensurada. Um grupo adicional de 48 amostras foi realizado para an?lise em M.E.V. Os resultados foram submetidos ao teste de ANOVA com tr?s fatores fixos (selantes, tempo e dentifr?cio) e de Tukey (&#945; = 5%). Resultados : BisCover apresentou a menor m?dia de rugosidade de superf?cie (0,06 &#956;m) quando comparado com os selantes Fortify (0,09 &#956;m) e Permaseal (0,08 &#956;m), os quais n?o foram estatisticamente diferentes entre si. O Fortify, em 12 meses de escova??o, apresentou a maior m?dia de rugosidade (0,13 &#956;m). A m?dia de rugosidade para o dentifr?cio CT foi menor (0,07 &#956;m) se comparado com o PW (0,08 &#956;m), sendo estatisticamente distintos. A rugosidade de superf?cie aumentou at? os 12 meses de escova??o simulada (0,04 &#956;m, 0,08 &#956;m e 0,11 &#956;m), diminuindo no 18? m?s (0,08 &#956;m) at? os 24 meses de escova??o (0,07 &#956;m). Conclus?es : o selante Fortify apresentou a maior m?dia de rugosidade em 12 meses de escova??o simulada, e os menores valores de rugosidade foram obtidos pelo BisCover. Atrav?s da M.E.V, observou-se que nenhum dos selantes utilizados no estudo foi removido completamente da resina at? os 24 meses de escova??o.
15

Avalia??o cl?nica de restaura??es indiretas em resina composta cimentadas com material resinoso convencional e autoadesivo

Marcondes, Maurem Leit?o 28 March 2014 (has links)
Made available in DSpace on 2015-04-14T13:30:33Z (GMT). No. of bitstreams: 1 458471.pdf: 1434696 bytes, checksum: 1b82056bbee62d1935b0803e571f0c64 (MD5) Previous issue date: 2014-03-28 / The aim of this study was to clinically evaluate the performance of indirect composite resin restorations cemented with conventional and self-adhesive resin cement, during a 12-month period. Twenty-four composite resin restorations were performed through indirect technique and cemented with two resin cements: a conventional (RelyX ARC) and a self-adhesive (RelyX U100). Two independent evaluators analyzed the restorations using the criteria of the USPHS (United States Public Health Service) modified after two weeks, six months and 12 months. For the analysis of data from USPHS, between the cements at the same time, it was used the Wilcoxon statistical test and for evaluation at different times, it was used the Mann-Whiney test, at significance level of 5 %. The Fisher exact test was used to assess the occurrence of absolute failures. No statistically significant differences were found between groups in the same period and between groups at different times, one statistical difference was found only for the criteria color match. We conclude that indirect composite resin restorations cemented with self-adhesive resin cement showed a similar performance of restorations cemented with conventional resin cement after a year of analysis. / O objetivo deste estudo foi avaliar clinicamente o desempenho de restaura??es indiretas de resina composta cimentadas com cimento resinoso convencional e autoadesivo no per?odo de 12 meses. Foram realizadas 24 restaura??es em resina composta (Filtek Supreme XT), executadas pela t?cnica indireta e cimentadas com dois cimentos resinosos: um convencional (RelyX ARC) e um autoadesivo (RelyX U100). Dois avaliadores independentes analisaram as restaura??es atrav?s dos crit?rios do USPHS (United States Public Health Service) modificado ap?s duas semanas, seis meses e 12 meses. Para a an?lise dos dados do USPHS, entre os cimentos no mesmo tempo, foi utilizado o teste estat?stico de Wilcoxon e, para avalia??o nos diferentes tempos, o Mann-Whiney ao n?vel de signific?ncia de 5%. O teste exato de Fisher foi usado para avaliar a ocorr?ncia de falhas absolutas. N?o foram encontradas diferen?as estatisticamente significativas entre os grupos no mesmo per?odo e entre os grupos nos diferentes tempos, havendo diferen?a estat?stica apenas para o crit?rio combina??o de cor. Pode-se concluir que restaura??es de resina composta indireta cimentadas com cimento resinoso autoadesivo tiveram um desempenho similar ?s cimentadas com cimento resinoso convencional ap?s um ano de avalia??o.
16

Avalia??o da transmit?ncia direta de resinas compostas por meio de espectrofotometria de UV-vis?vel

Masotti, Alexandre Severo 21 January 2005 (has links)
Made available in DSpace on 2015-04-14T13:30:41Z (GMT). No. of bitstreams: 1 330875.pdf: 1305514 bytes, checksum: 089a799a5a900dcf1c58a4ca2f0e1710 (MD5) Previous issue date: 2005-01-21 / Este estudo avaliou as porcentagens de Transmit?ncia direta (Td) das resinas compostas microh?bridas Charisma F, Solitaire II (Heraeus Kulzer ), Intens e Tetric Ceram (Ivoclar Vivadent) e nanoparticuladas Esthet-X (Dentsply De trey) e Filtek Supreme (3M Espe) nas cores Vita A3 (Dentina) e transl?cido (Esmalte), ou seus correspondentes. Foram confeccionados tr?s corpos-de-prova para cada material e cor, de formato quadrangular com 12x12 mm de lado e espessura de 1 mm. Ap?s fotoativa??o, foram realizadas tr?s leituras por corpo-de-prova em espectrofot?metro de UV-vis?vel HP 8453 (Hewlett-Packard), com temperatura e umidade controladas (22?2?C/50?5%). Os ?ngulos de incid?ncia e leitura em 0? / 0? foram utilizados para os comprimentos de onda de 400 a 700 nm. Os espectros obtidos foram analisados quanto ao percentual m?dio de Td para todo o espectro, em intervalos de 20 nm, e nos comprimentos de onda de 400, 560 e 700 nm. Atrav?s de ANOVA e teste de Tukey (p=0,01) encontrou-se que a resina composta Charisma obteve as maiores porcentagens de Td em todos os espectros, exceto para a cor Esmalte em 700 nm, que ficou abaixo da resina composta Esthet-X cor Esmalte. O teste t-Student demonstrou serem significativamente maiores os percentuais de Td para os espectros das cores Transl?cido, exceto para as resinas compostas Supreme, em que n?o diferiram, e Charisma, com porcentagens de Td significativamente maiores para a cor Dentina. Por meio de teste n?o param?trico de Friedman verificou-se que todas as resinas compostas estudadas demonstraram aumento significativo de Td com o aumento do comprimento de onda, com exce??o da resina composta Solitaire, cores Dentina e Esmalte, que n?o demonstrou diferen?as significativas nos comprimentos de onda de 560 e 700 nm.
17

Avalia??o da resist?ncia de uni?o e da adapta??o interna entre cavidade dentin?ria e adesivos aplicados em uma e duas camadas

Soares, Clarissa Grassi 14 December 2007 (has links)
Made available in DSpace on 2015-04-14T13:29:14Z (GMT). No. of bitstreams: 1 398957.pdf: 156371 bytes, checksum: ef32419ab3a2f6ff5a17e3f6a5e25149 (MD5) Previous issue date: 2007-12-14 / Esta pesquisa avaliou a influ?ncia do n?mero de camadas de adesivo de tr?s sistemas adesivos sobre: 1) a resist?ncia de uni?o ? microtra??o (&#956;T) ? dentina e o padr?o de fratura; 2) a adapta??o interna (AInt) entre estrutura dentin?ria e restaura??o de resina composta. Nas faces vestibulares de 30 incisivos bovinos foram confeccionadas duas cavidades, uma incisal e uma cervical, distantes 2 mm entre si, com 4 x 4 x 2 mm nas amostras para a AInt e 3,5 x 3,5 x 1,5 mm para a &#956;T (fator C=3). Os adesivos Scotchbond Multi- Uso (MP), Single Bond 2 (SB) (3M/ESPE) e Clearfil SE Bond (CF) (Kuraray) foram aplicados em uma camada (MP-I, SB-I e CF-I) e em duas camadas (MP-II, SB-II e CF-II), sendo fotopolimerizadas separadamente por 20 s. A resina composta Z250 (3M/ESPE), na cor A3, foi inserida em incrementos. Para cada sistema adesivo foram utilizados dez dentes, sendo cinco para cada teste. Ap?s 48 h foram obtidos palitos de resina/dentina (n=15/grupo), com ?rea adesiva m?dia de 0,53 mm2, para a &#956;T, e fatias com espessura entre 0,15 - 0,20 mm contendo as duas restaura??es (n=15/grupo) para a AInt. Os palitos foram submetidos ao ensaio de &#956;T na m?quina EMIC DL2000 e, ap?s o teste, as extremidades foram analisadas em MEV para classifica??o do padr?o de fratura. As fatias foram analisadas com 10 x de aumento em microsc?pio ?ptico Leica DMR com sistema de luz polarizada e contraste interferencial. As imagens das restaura??es foram capturadas por uma c?mera digital Nikon Coolpix 990, sendo analisados os tipos e quantidades de falhas (fenda, trinca, ruptura). Os valores m?dios de &#956;T foram submetidos ? ANOVA Fatorial e teste de Tukey (?=0,05).Os fatores adesivos (p=0,001) e camadas (p=0,025) apresentaram diferen?a significativa, mas a intera??o entre eles n?o teve diferen?a significativa (p=0,189). Os valores m?dios de &#956;T foram os seguintes: MP-II: 56,92; MP-I: 52,23; CF-II: 47,77; CFI: 42,25; SB-I: 35,12; SB-II: 34,69. A fratura do tipo mista foi predominante. Em rela??o ? AInt, houve diferen?a estat?stica entre os adesivos para trincas e rupturas de acordo com o teste de Kruskal-Wallis (?=0,05). O SB-I e II teve os maiores valores de trincas e, o MP-I, os menores. Para rupturas, SB-II apresentou valores estatisticamente superiores. A aplica??o de duas camadas n?o favoreceu os resultados de &#956;T e de AInt.
18

Influ?ncia do laser de Nd:Yag na resist?ncia de uni?o de Materiais resinosos ? dentina. Efeito do laser de Nd : Yag e de Er:Yag na interface adesivodentina : estudo em MEV

Ghiggi, Paula Cristine 14 January 2009 (has links)
Made available in DSpace on 2015-04-14T13:29:21Z (GMT). No. of bitstreams: 1 409045.pdf: 2621932 bytes, checksum: 3dd68f9c8fb1c8ea3799e2e33658b7c3 (MD5) Previous issue date: 2009-01-14 / Este estudo avaliou a resist?ncia de uni?o de diferentes materiais adesivos ? dentina irradiada com laser de Nd:YAG. Dezoito terceiros molares humanos, extra?dos por indica??o terap?utica, tiveram as ra?zes embutidas em resina acr?lica quimicamente ativada. A dentina oclusal foi exposta pela remo??o do esmalte com disco diamantado, seguido de acabamento com lixas de carbeto de sil?cio 400 e 600 sob refrigera??o. Os dentes foram divididos aleatoriamente em seis grupos: G1: sistema adesivo Adper Single Bond 2; G2: sistema adesivo Clearfil SE Bond; G3: cimento resinoso auto-adesivo Rely X Unicem; G4: irradia??o com o laser de Nd:YAG e aplica??o do sistema adesivo Adper Single Bond 2; G5: irradia??o com o laser de Nd:YAG e aplica??o do sistema adesivo Clearfil SE Bond; G6: irradia??o com o laser de Nd:YAG e aplica??o do cimento resinoso auto-adesivo Rely X Unicem. O laser foi aplicado nos par?metros de 60 mJ, 15 Hz, 0,9 W, 47,70 J/cm2, dura??o do pulso 100 &#956;s. Um bloco de resina composta, com aproximadamente 6 mm de altura, foi constru?do, de forma incremental, sobre os materiais adesivos. Os conjuntos dente/restaura??o foram armazenados em ?gua destilada por 24 horas a 37oC, e ent?o seccionados com disco diamantado em cortadeira de precis?o para obten??o de corpos-de-prova na forma de palitos. Vinte corpos-de-prova foram selecionados para cada grupo, sendo submetidos ao teste de microtra??o em m?quina de ensaio universal EMIC DL-2000 com velocidade de 0,5 mm/minuto. Os resultados foram submetidos ? An?lise de Vari?ncia e teste de Tukey ( =0,05). O maior valor m?dio de resist?ncia de uni?o foi obtido para o Clearfil SE Bond (41,75 MPa) sem aplica??o do laser. No entanto, quando o laser foi aplicado, houve uma redu??o no valor de resist?ncia de uni?o (33,42 MPa), por?m sem diferen?a estatisticamente significante. A resist?ncia de uni?o do Adper Single Bond 2 sem laser (32,15 MPa) tamb?m n?o diferiu estatisticamente com a aplica??o do laser (35,38 MPa). O cimento resinoso Rely X Unicem proporcionou os menores valores de resist?ncia de uni?o, sendo o valor da resist?ncia de uni?o com aplica??o do laser (7,53 MPa) estatisticamente inferior quando o mesmo n?o foi aplicado (14,50 MPa). Concluiu-se que o laser de Nd:YAG n?o influenciou significativamente a resist?ncia de uni?o dos sistemas adesivos, mas apenas para o grupo do cimento resinoso auto-adesivo
19

Influ?ncia do ?cido poliacr?lico na interface e resist?ncia de uni?o de cimentos resinosos autoadesivos ? dentina

Stona, Priscila 17 January 2011 (has links)
Made available in DSpace on 2015-04-14T13:29:51Z (GMT). No. of bitstreams: 1 429330.pdf: 4876127 bytes, checksum: 03e0c09981d2813cd511c4f745b49744 (MD5) Previous issue date: 2011-01-17 / O objetivo desse estudo foi avaliar a interface e a resist?ncia de uni?o de cimentos resinosos autoadesivos ? dentina condicionada com ?cido poliacr?lico a 11,5%. Cinquenta e seis dentes, terceiros molares, foram divididos aleatoriamente em 7 grupos (n=24/grupo): G1 (controle) - Rely X ARC; G2 - RelyX Unicem; G3 - Maxcem Elite; G4 - Set; G5 - ?cido poliacr?lico + Rely X Unicem; G6 - ?cido poliacr?lico + Maxcem Elite; G7 - ?cido poliacr?lico + Set. Blocos de resina composta foram cimentados sobre dentina plana com carga de 1Kg por 2 minutos, seguido de fotoativa??o. Ap?s armazenagem em ?gua destilada a 37? C por 24 horas, seis conjuntos dente/resina foram cortados, paralelamente ao longo eixo do dente, nos sentidos x e y, com sec??o de aproximadamente 0,8 mm2. Foram obtidos 24 corpos de prova para cada grupo, sendo ent?o submetidos ao teste de resist?ncia ? microtra??o (RZt) em m?quina de ensaio universal com velocidade de 0,5 mm/min. Dois conjuntos de cada grupo foram seccionados no sentido m?sio-distal, no centro de suas coroas, com um disco diamantado de dupla face. As superf?cies foram polidas com lixas de carbeto de sil?cio 400, 600 e 1200, seguido de polimento com pastas dimantadas de granula??o 6, 3, 1 e ? &#956;m. As amostras foram desmineralizadas, desproteinizadas, secadas, metalizadas e observadas em microsc?pio eletr?nico de varredura em aumento de 4.000 vezes. De acordo com An?lise de Vari?ncia e teste de Tukey (a=0,05), a m?dia de RZt do RelyX ARC (24,19 MPa) e do RelyX Unicem associado ao ?cido poliacr?lico (23,12 MPa) n?o diferiram estatisticamente entre si e foram superiores aos outros grupos (p<0,05). A m?dia de RZt do Maxcem Elite associado ao ?cido poliacr?lico (13,09 MPa) foi, estatisticamente, superior ao Maxcem Elite sem ?cido poliacr?lico (8,14 MPa). O RelyX Unicem sem ?cido poliacr?lico (10,23 MPa) n?o diferiu, estatisticamente, do Maxcem Elite sem e com ?cido poliacr?lico. Todos os corpos de prova do Set foram perdidos durante o procedimento de corte. Para os cimentos resinosos autoadesivos n?o foi observada forma??o de camada h?brida, havendo a forma??o de tags de resina para o RelyX Unicem e Maxem Elite quando associados ao ?cido poliacr?lico. O pr?-tratamento com ?cido poliacr?lico a 11,5% foi efetivo para a uni?o do RelyX Unicem e Maxcem Elite ? dentina.
20

Influ?ncia de cimentos resinosos autoadesivos na deflex?o de c?spides e carga de fratura de pr?-molares restaurados com inlays em resina composta

Salaverry, Aur?lio 18 March 2011 (has links)
Made available in DSpace on 2015-04-14T13:29:54Z (GMT). No. of bitstreams: 1 431091.pdf: 6484611 bytes, checksum: ee0b40e71498d6a5f8496211522ca10f (MD5) Previous issue date: 2011-03-18 / O objetivo desse estudo foi avaliar a influ?ncia de quatro cimentos resinosos (um convencional e tr?s autoadesivos) na deflex?o de c?spides, carga de fratura e tipos de fratura de pr?-molares com acesso endod?ntico e restaurados com inlays em resina composta. Setenta e dois primeiros pr?-molares foram divididos aleatoriamente em seis grupos (n=12): G1 (controle) - h?gidos; G2 cavidades sem restaura??o; G3 RelyX ARC; G4 RelyX U100; G5- Maxcem Elite; G6 SeT. Os Grupos 2-6 receberam preparos cavit?rios MOD e acesso endod?ntico. Os grupos 3-6 foram moldados com silicona por adi??o e vazados com gesso especial para confec??o de inlays em resina composta Z350 XT. As restaura??es indiretas foram cimentadas nas respectivas cavidades com carga de 1 Kg e fotoativadas. Ap?s armazenagem em ?gua destilada a 37? C por 72 horas, carga de 200 N foi aplicada na regi?o oclusal com uma esfera de 8 mm de di?metro acoplada na m?quina de ensaio universal EMIC DL 2000, sendo medida a deflex?o de c?spides com um micr?metro digital. Os corpos de prova foram ent?o submetidos a 500.000 ciclos de fadiga mec?nica, e novo teste de deflex?o de c?spides foi realizado. Em seguida, os corpos de prova foram submetidos ao ensaio de compress?o at? a fratura na m?quina de ensaio universal. De acordo com o teste de Kruskal-Wallis, a maior deflex?o de c?spides pr?-fadiga foi obtida para o grupo 2 (69 &#956;m), n?o diferindo estatisticamente do grupo 6 (51 &#956;m). As menores deflex?es de c?spides foram obtidas para o grupo 1 (4 &#956;m), o grupo 3 (4 &#956;m) e o grupo 4 (5 &#956;m), os quais n?o diferiram estatisticamente entre si. Valor intermedi?rio foi obtido para o grupo 5 (21 &#956;m), n?o diferindo estatisticamente dos grupos 3, 4 e 6. De acordo com o teste de Wilcoxon, n?o houve diferen?a estat?stica entre a deflex?o de c?spides pr? e p?s-fadiga apenas para o grupo 3 (p=0,015). De acordo com Kruskal-Wallis, a maior carga de fratura foi obtida para o grupo 1 (1902 N), diferindo estatisticamente dos outros grupos. Segundo maior valor foi obtido para o grupo 3 (980,8 N), diferindo estatisticamente dos outros grupos. Grupo 4 (670,6 N), grupo 5 (533,5 N), grupo 6 (601,3 N) e grupo 2 (526,6 N) n?o diferiram estatisticamente entre si. Para os grupos restaurados, houve predomin?ncia de fraturas recuper?veis. Inlays em resina composta cimentadas com RelyX ARC mantiveram a estabilidade da deflex?o de c?spides, proporcionaram maior recupera??o da resist?ncia da estrutura dent?ria, assim como fraturas mais favor?veis para a reabilita??o.

Page generated in 0.0224 seconds