"InfluÃncia dos protocolos de fotoativaÃÃo na microdureza e no grau de conversÃo de uma resina composta" / "Influence of curing protocols on microhardness and degree of conversion of a composite resin"AndrÃa GalvÃo Marinho Bomfim 02 October 2009 (has links)
FundaÃÃo de Amparo à Pesquisa do Estado do Cearà / O objetivo deste trabalho foi avaliar in vitro o grau de conversÃo da resina composta Filtek Z 350 (3M ESPE), na cor A3, empregando a luz halÃgena pelo aparelho VIP (Variable Intensity Polymerizer) JÃnior (Bisco), utilizando trÃs protocolos de fotoativaÃÃo, a saber: convencional 500mW/cm por 40s; gradual 300mW/cm por 3s e, em seguida, 500mW/cm por 30s; pulso tardio 300mW/cm por 3s, com pausa de 3 min; e 300mW/cm por 30s. O grau de conversÃo da resina foi obtido atravÃs do teste de microdureza Knoop e espectrografia Raman. Uma matriz metÃlica, bipartida, com orifÃcio central de 2,5mm de profundidade e 5mm de diÃmetro, foi utilizada para confecÃÃo dos corpos de prova, que foram fotoativados segundo os protocolos descritos. Foram confeccionados cinco corpos de prova de cada tipo de protocolo para o ensaio de microdureza e uma amostra de cada protocolo para o teste de Raman. Os testes foram realizados 24 horas apÃs a polimerizaÃÃo dos corpos de prova, que foram armazenados a seco, ao abrigo da luz e à temperatura ambiente. Na microdureza, cinco indentaÃÃes foram realizadas em cada superfÃcie (topo e base) do corpo de prova com uma carga de 10gf por 10s. O Raman foi realizado no centro da amostra do topo e da base. Os resultados obtidos foram submetidos à AnÃlise de VariÃncia a 2 critÃrios e ao teste de comparaÃÃes mÃltiplas de Student-Newman-Keuls, a um nÃvel de significÃncia de 5%. Pode-se observar que houve diferenÃas estatisticamente significantes entre os protocolos de fotoativaÃÃo utilizados, quando a anÃlise foi realizada no topo dos espÃcimes, sendo que a fotoativaÃÃo convencional apresentou os maiores valores de dureza. Entretanto, quando a mensuraÃÃo da dureza foi realizada na extremidade oposta dos espÃcimes (base), nÃo foram observadas diferenÃas estatisticamente significantes entre os protocolos de fotoativaÃÃo. Contudo, nas comparaÃÃes entre os valores de dureza observados em relaÃÃo à localizaÃÃo da mensuraÃÃo (topo ou base), pode-se observar que os valores obtidos no topo dos espÃcimes foram estatisticamente superiores aos observados na base dos mesmos, com exceÃÃo do protocolo pulso tardio, onde nÃo houve diferenÃa estatÃsticamente significante ente as superfÃcies do topo e da base. O teste de Raman confirmou os resultados achados na microdureza, com o grau de conversÃo da resina, sendo maior nas superfÃcies de topo e com maior conversÃo dos protocolos convencional e soft start. / This study evaluate the degree of conversion of composite resin Filtek Z 350 (3M ESPE), on shade A3, using halogen light VIP (Variable Intensity Polymerizer) Junior (Bisco) utilizing three light curing protocols, they are: standard 500mW/cm by 40 sec; soft start 300mW/cm by 3 sec and after 500mW/cm by 30 sec; pulse delay 300mW/cm by 3 sec, stop by 3 min and 100mW/cm by 30 sec. The degree of conversion of the resin was analyzed by the test of microhardness Knoop and Raman spectrography. Five samples of each type of protocol for the microhardness test had been confectioned and one sample of each protocol for the test of Raman. The tests had been made 24 hours after the polymerization of the samples, that had been stored the dry one, protected from the light and at room temperature. In the microhardness, five indentations had been made in each surface (top and bottom) of the sample with a load of 10gf for 10s. The Raman was obtained from the center of the sample of the top and the bottom surfaces. The results had been submitted the Two-Way ANOVA and to the test of multiple comparisons of Student-Newman-Keuls, to a level of significance of 5%. It can be observed that it had statistical significant differences between the used curing protocols when the analysis was made in the top of specimens, being that the standard curing protocol presented biggest values of hardness. However, when the value of the hardness was obtained from in the opposing extremity of specimens (bottom), statistical significant differences between the curing protocols had not been observed. In the comparisons between the values of hardness observed in relation to the localization of the indentation, it can be observed independently that the values obtained in the top of specimens had been statistical differences, with exception for the protocol pulse delay, where had not significant statistical difference between the surfaces of top and bottom. The test of Raman confirmed the results finds in the microhardness, with the degree of conversion of resin higher in top surface, and with bigger degree of conversion of the conventional and soft start protocols.
|
22 |
Análise da qualidade da polimerização e da degradação de cimentos resinosos utilizados na cimentação de pinos de fibra de vidro por meio de testes de microdureza / Microhardness analysis of the polymerization quality and degradation of resin cements used for fiber posts cementationAna Paula Ribeiro do Vale Pedreira 16 April 2007 (has links)
Os cimentos resinosos têm sido largamente utilizados em odontologia restauradora com a finalidade de reter o pino intra-radicular e dissipar tensões entre este e a raiz. Entretanto, o grau de conversão alcançado pelos mesmos influencia suas propriedades mecânicas, biocompatibilidade e degradação pela água e pelos ácidos bucais. Testes de microdureza podem ser aplicados para estimar o grau de conversão de compósitos, uma vez que apresentam boa correlação com a espectroscopia infravermelha. Este trabalho objetivou analisar a microdureza de quatro cimentos resinosos de polimerização dual utilizados na cimentação de pinos de fibra de vidro, nos períodos inicial, após 24 horas de imersão em etanol a 75% e após 3 meses de armazenamento em água, e testar a hipótese de que não há diferença entre a microdureza dos terços cervical, médio e apical na linha de cimento. Quarenta incisivos bovinos tratados endodonticamente foram distribuídos em quatro grupos para a cimentação de pinos Fibrekor® (Jeneric/Pentron) de 1mm de diâmetro, sendo: Grupo 1 - Panavia F 2.0 (Kuraray Medical Inc.), Grupo 2 - Variolink (Ivoclar), Grupo 3 - Rely X Unicem (3M ESPE) e Grupo 4 - Duolink (Bisco). Após a cimentação, as raízes foram divididas em 2 subgrupos, sendo 5 seccionadas após 7 dias para análise da microdureza inicial e 5 mantidas íntegras em água deionizada por 3 meses, para avaliação da microdureza final no microdurômetro Shimadzu HMV (Japan). Após a mensuração inicial, as raízes seccionadas eram armazenadas a 37º C por 24h em 10mL de solução de etanol a 75%, e reavaliadas. Foram identificadas diferenças estatisticamente significativas entre cimentos, terços e períodos (inicial ou após 24h de imersão em etanol a 75%), bem como interações entre cimento/terços e cimento/períodos de avaliação. O cimento Panavia exibiu os valores de microdureza inicial significativamente superiores, sem diferença estatística entre os demais cimentos. Os valores de microdureza inicial por terços não seguiram um padrão homogêneo; os cimentos Variolink e Duolink exibiram valores de microdureza significativamente superiores no terço cervical, sem diferença significativa entre os terços para os demais cimentos. A imersão em etanol reduziu significativamente a média dos valores de dureza para todos os cimentos; o comportamento por terços variou em função do material. O armazenamento em água por 3 meses não exerceu influência sobre a dureza da maioria dos cimentos, com exceção do Unicem, que exibiu aumento significativo dos valores de dureza após esse período. Portanto, a hipótese proposta neste estudo foi rejeitada. / Resin cements have been largely used in dentistry for retaining intraradicular posts and to minimize tension between them. However, the degree of conversion influences mechanical properties, biocompatibility and susceptibility of water and acid degradation of these polymers. Hardness tests are used to estimate the degree of conversion of composites, as it shows good correlation with infrared spectroscopy. The aim of this study was to evaluate the microhardness of four resin cements used for fiber posts cementation at the nitial period, 24h-immersion in a 75% ethanol solution and after 3-month water storage. Forty bovine incisives were endodontically treated and restored with 1mm diameter Fibrekor® posts (Jeneric/Pentron), being: Group 1 - Panavia F 2.0 (Kuraray Medical Inc.), Group 2 - Variolink (Ivoclar), Group 3 - Rely X Unicem (3M ESPE) and Group 4 - Duolink (Bisco). After cementation, each group was divided in two subgroups: 5 roots were sectioned 7 days after cementation for initial hardness measurement and 5 roots were immersed in deionized water for 3 months for final hardness measurements using Shimadzu Micro Hardness Tester (HMV, Japan). After the initial measurements, the sectioned roots were immersed in 10mL 75% ethanol solution for 24h at 37ºC, and tested again. Differences in hardness values have been detected among resin cements, radicular thirds and periods (initial or 24h-immersion in a 75% ethanol solution). Data also revealed significant interaction to cement/third and cement/period of evaluation. Panavia showed higher hardness values, with no statistical differences among the other cements. It was not verified a homogeneous pattern regarding radicular third; Variolink and Duolink exhibited higher hardness values for the cervical third, without differences among radicular thirds for the other cements. Hardness values decreased after ethanol immersion for all resin cements and the hardness according to radicular thirds varied among the materials. The hardness of tested resin cement showed no influence after 3-month water storage, except for Unicem as it showed an increase in Knoop hardness after this period. Therefore, the null hypotesis proposed was rejected.
|
23 |
Influência da composição e cor de cerâmicas na transmissão de luz e no grau de conversão de cimentos resinosos de ativação dual / Effect of ceramic composition and shade in light transmission and degree of conversion of dual-cure resin cementsLuana Menezes de Mendonça 14 September 2015 (has links)
O objetivo desta pesquisa foi avaliar a transmitância de diferentes tipos e cores de cerâmicas e seus efeitos no grau de conversão (GC) de dois tipos de cimentos resinosos com modo de polimerização dual. Foram confeccionadas 60 pastilhas com a cerâmica IPS e.max (Ivoclar Vivadent, Schaan, Liechtenstein) e divididas em 3 grupos: LT, MO e Z, com 20 pastilhas cada um. Nos grupos LT e MO, as pastilhas foram confeccionadas com a cerâmica de dissilicato de lítio de baixa translucidez (LT - low transluscency) e de média opacidade (MO - medium opacity), respectivamente. No grupo Z, as pastilhas foram confeccionadas em zircônia. Cada grupo foi subdividido em 5 subgrupos (n=4), de acordo com a cor da cerâmica: A2; A3,5; B2; C2; D3. No grupo LT, as pastilhas foram prensadas nas cores anteriormente citadas e, nos grupos MO e Z, as pastilhas foram, inicialmente, confeccionadas para simular infraestruturas e, posteriormente, receberem aplicação de cerâmica de revestimento IPS e.max Ceram (Ivoclar Vivadent, Schaan, Liechtenstein) nas mesmas cores. O espectrofotômetro UV 1800 Shimadzu foi utilizado para medir a transmitância de cada espécime de cerâmica (2,0 mm de espessura). Para medir o GC, espécimes dos cimentos resinosos Variolink II (Ivoclar Vivadent, Schaan, Liechtenstein) e Rely X U200 (3M ESPE, St. Paul, MN, USA), com espessura de 100 μm, foram fotopolimerizados sob os discos de cerâmica por 40 s. Espécimes dos cimentos fotoativados sem a interposição da cerâmica foram usados como grupo controle. A polimerização dos cimentos foi avaliada através da espectrometria no infravermelho com transformada de Fourier (FTIR) empregando o método de reflexão atenuada total (ATR) imediatamente após a fotopolimerização. Os resultados foram submetidos aos testes ANOVA a 1 critério e Teste de Tukey (α=5%). Os valores de transmitância foram inferiores a 1%, sendo que as do grupo LT apresentaram, em geral, os maiores valores de transmitância, seguidos dos grupos MO e Z. O GC do cimento Variolink II não sofreu influência da interposição da pastilha de cerâmica. Para o cimento Rely X U200, a interposição de alguns tipos/cores de cerâmica (LT A3,5; MO A2; MO A3,5 e Z A3,5) diminuíram o GC em relação ao grupo controle. Concluiu-se que os valores de transmitância e GC foram influenciados pelos tipos/cores de cerâmica. Entretanto, somente o grupo formado pela cerâmica de dissilicato de lítio LT, usando o Rely X U200, apresentou correlação negativa entre transmitância e GC. / The aim of the present study was to evaluate the transmittance of different ceramic types and shades and their effects on the degree of conversion (DC) of two dual-cure resin cements. Sixty discs were fabricated with IPS e.max ceramic (Ivoclar Vivadent, Schaan, Liechtenstein) and divided into three groups (n= 20 in each group): LT, MO and Z. For LT and MO groups discs were fabricated with low translucency (LT) and medium opacity (MO) lithium disilicate ceramic, respectively. Discs from Z group were manufactured of zirconia. Each group was divided into five subgroups (n = 4), according to the ceramic shade: A2; A3,5; B2; C2; D3. In the LT group, specimens were heat-pressed in shades cited above and in the MO and Z groups, the discs were initially fabricated as core materials and then veneered with veneer ceramic (IPS e.max Ceram, Ivoclar Vivadent, Schaan, Liechtenstein) in the same shades. A spectrophotometer UV-1800 Shimadzu was used to determine the transmittance percentage of each ceramic specimen (2.0-mm-thick). For DC measurements, the resin cements (Variolink II - Ivoclar Vivadent, Schaan, Liechtenstein and Rely X U200 - 3M ESPE, St. Paul, MN, USA) specimens (thickness: 100 μm) were photocured under the ceramic discs (2.0-mm-thick) for 40 s. Specimens photocured without the ceramics discs were used as control group. ATR/FTIR spectrometry was used to evaluated the extent of polymerization for all cement specimens immediately after photocuring. The results were submitted to one-way ANOVA and Tukey test (α=5%). The transmittance percentage was less than 1% and the LT group had the highest transmittance values, followed by MO and Z groups. The %DC of Variolink II cement was not influenced by the ceramic disc interposition. For Rely X U200 cement, the interposition of some ceramics types/shades (LT A3,5, MO A2, MO A3,5 and Z A3,5) significantly decreased the %DC compared to control group. It was concluded that the transmittance values and %DC were influenced by the ceramics types/shades. However, only the LT group, using the Rely X U200, showed a negative correlation between transmittance and %DC.
|
24 |
Influência do pré-aquecimento e de diferentes regimes de fotoativação na adaptação marginal, grau de conversão e propriedades mecânicas de um compósito nanoparticulado / Influence of preheating and different photoactivation modes on marginal adaptation, degree of conversion and mechanical properties of a nanofiller compositeNívea Regina de Godoy Fróes Salgado 27 May 2008 (has links)
Proposição: O objetivo deste estudo foi verificar a influência do pré-aquecimento e de regimes de fotoativação (dois contínuos e um em dois passos com baixa irradiância inicial) sobre a adaptação marginal de restaurações, grau de conversão (GC), resistência à flexão (RF) e microdureza Knoop (KHN) de um compósito. Material e Métodos: O nanocompósito Filtek Z350 foi submetido às seguintes condições experimentais: com ou sem pré-aquecimento a 68ºC através do dispositivo Calset; e fotoativado através de um dos três regimes a seguir: 600mW/cm2 por 20s ou 40s (12 ou 24J/cm2 respectivamente) ou 200mW/cm2 por 20s + intervalo de 1 minuto + 500mW/cm2 por 40s (24J/cm2). O teste de adaptação marginal foi realizado através de microscopia eletrônica de varredura, com a mensuração de gaps em réplicas de cavidades Classe V (n=10) em aumento de 200X. A interface adesiva foi dividida em sete segmentos para o cálculo de freqüência de gaps. GC foi obtido através de espectroscopia em FT-Raman nas faces irradiada e oposta de espécimes (n=3) mantidos durante 24h em ambiente escuro a 37°C. RF do compósito foi medida por ensaio de dobramento em três pontos em espécimes (n=10) armazenados em água destilada por 24h. KHN foi mensurada inicialmente (n=6) após 24h de estocagem a seco. Foi realizada armazenagem em etanol 100%, seguida de segunda medida para o cálculo da redução percentual de KHN. Os resultados foram analisados através de análise de variância e teste de Tukey (=0,05) para os testes de GC, RF e KHN e com os testes de Friedman, Wilcoxon e Kruskal-Wallis para a adaptação marginal. Resultados: As paredes axiais das restaurações apresentaram maior freqüência de gaps quando comparadas às laterais. O pré-aquecimento do compósito reduziu a freqüência de gaps. Os regimes de fotoativação demonstraram freqüência de gaps semelhantes entre si. No teste de GC apenas o fator face foi estatisticamente significativo (p<0,05), com maiores valores médios para as faces irradiadas. O regime de ativação em dois passos causou redução (p<0,01) dos valores médios de RF. No teste de KHN após 24h tanto os fatores principais como a interação apresentaram-se estatisticamente significativos (p<0,05 para modo de fotoativação, p<0,001 para pré-aquecimento e p<0,05 para a interação). Os grupos pré-aquecidos demonstraram em geral menores médias de KHN do que aqueles sem aquecimento. Comparando-se os grupos sem pré-aquecimento, não houve diferença em função do modo de fotoativação. Entre os grupos pré-aquecidos, houve diminuição de KHN para 600mW/cm2 por 20s. Na KHN após etanol apenas o fator pré-aquecimento foi significativo (p<0,001), com as menores médias apresentadas pelos grupos pré-aquecidos. A redução percentual da KHN após armazenamento em etanol ocorreu de forma uniforme para todos os grupos. Conclusões: O pré-aquecimento do compósito estudado promoveu melhor vedamento da interface adesiva sem, no entanto, afetar seu grau de conversão e resistência à flexão. O regime de fotoativação com baixa irradiância inicial reduziu a resistência à flexão do compósito, apesar de produzir grau de conversão similar ao de formas contínuas. O pré-aquecimento pode reduzir a microdureza da superfície irradiada de um compósito. / Proposition: The objective of this study was to verify the influence of preheating and photoactivation modes (two continuous and one in two steps with a low initial irradiance) on restoration marginal adaptation, degree of conversion (DC), flexural strength (FS) and Knoop microhardness (KHN) of a composite. Material and Methods: The nanocomposite Filtek Z350 was evaluated under the following experimental conditions: pre-heated up to 68ºC with the use of Calset device or without preheating; and photoactivated through one of the three regimens: 600mW/cm2 for 20s or 40s (12 and 24J/cm2 respectively) and one in two steps (200mW/cm2 for 20s + 1 minute delay + 500mW/cm2 for 40s (24J/cm2). Marginal adaptation test was performed by scanning electron microscopy, measuring gaps in Class V replica (n=10) under 200X magnification. The adhesive interface was segmented in seven parts for gaps frequency calculus. DC was obtained by FT-Raman spectroscopy in irradiated and non-irradiated surfaces (n=3) of samples stored in dark for 24h at 37C . FS was evaluated in a three-bending test in samples (n=10) after 24h storage in distilled water. KHN was measured (n=6) initially after 24h dark and dry storage. After that, samples were stored in 100% ethanol and KHN percentual reduction calculated. Results were analysed by ANOVA and Tukey\'s test (=0.05) DC, FS and KHN and with Friedman, Wilcoxon and Kruskal-Wallis tests for marginal adaptation. Results: Axial walls of the restorations showed higher gaps frequency than lateral walls. Composite preheating leaded to a lower gaps frequency. Photoactivation modes demonstrated similar gap frequency. In DC test only the main factor surface was significant (p<0.05), with higher mean values for irradiated surfaces. The two steps regimen reduced (p<0.01) mean FS values. About KHN after 24h, both main factors and their interaction were significant (p<0.05 for photoactivation mode, p<0.001 for pre-heating use and p<0.05 for interaction). Generally pre-heated groups showed lower KHN means than non-preheated. Comparing non-preheated groups there was not a statistical difference regardless the photoactivation mode. In preheated groups, KHN mean for 600mW/cm2 during 20s was lower than means for other irradiation regimens. In KHN after ethanol, the main factor pre-heating was significant (p<0.001). Preheated groups showed lower means than non-preheated. KHN percentual reduction after ethanol storage occured in a uniform way for all groups. Conclusions: Preheating of the nanocomposite in study promoted a better adhesive interface sealing without compromising the degree of conversion and flexural strength. The photoactivation method that uses a low initial irradiance reduced composite flexural strength in spite of the similar degree of conversion was reached, comparing to continuous modes. Pre-heating can reduce irradiated surface microhardness.
|
25 |
Desenvolvimento de tensões de polimerização determinado através do método da propagação de trincas / Development also polymerization stress determined by crack analysis methodsThayse da Costa Guimarães 30 August 2013 (has links)
O objetivo do presente estudo foi avaliar o desenvolvimento das tensões de polimerização de um compósito resinoso restaurador ao longo das primeiras 24 horas após a fotoativação, segundo dois métodos de análise da propagação de trincas. A influência do armazenamento em água sobre a magnitude das tensões também foi avaliada. O grau de conversão (GC) e o módulo de elasticidade (E) do compósito foram determinados nos diferentes tempos de observação. As hipóteses nulas do trabalho foram: 1) tensão de polimerização, GC e E não variam de forma significativa ao longo do período de observação; 2) os dois métodos de análise de propagação de trincas fornecem resultados semelhantes; 3) os valores de tensão não são influenciados pelo meio de armazenamento. Foram confeccionados discos de vidro de soda-cal com 2 mm de espessura, diâmetro externo de 12 mm, com perfuração central de 4 mm de diâmetro. Os discos foram aleatorizados em três grupos. Em um deles, os discos foram restaurados (Charisma Diamond, Heraeus Kulzer) e, após os tempos de 10 min, 1, 2, 4, 8 ou 24 horas (n=10), os espécimes receberam quatro indentações Vickers, (9,8N por 20s) a 500m da margem da cavidade. O segundo grupo passou pelo mesmo processo, porém os discos ficaram armazenados em água antes de serem indentados. Em seguida, o comprimento das trincas e a diagonal da indentação foram mensurados em microscópio óptico. A tensão residual no vidro foi calculada de acordo com a norma 4-01 (The Society of Materials Science, JSMS, Japão). No terceiro grupo, os discos foram indentados e armazenados em dissecador por 24h antes de serem restaurados. As trincas foram medidas antes e após a restauração, nos mesmos tempos descritos acima, e a tensão calculada de acordo com a fórmula descrita por Yamamoto et al. (Dent Mater, 2009). O GC foi determinado por espectroscopia no infra-vermelho próximo (n=3). O E foi obtido através do teste de dobramento em três pontos (n=10). Os dados foram submetidos a ANOVA/Tukey (=0,05) e análise de regressão. A tensão de polimerização, assim como o GC e o E tiveram seus valores aumentados ao longo do tempo. O GC aumentou 28% entre 10 minutos e 24 horas, para o E houve um aumento de 1,7 GPa para 6,3 GPa entre 10 minutos e 24 horas. A tensão de polimerização aumentou 40% entre 10min e 24h para a norma 4-01 e 51% para o método do Yamamoto et al. O meio de armazenamento foi estatisticamente significativo até o tempo de 4 horas. Portanto, a primeira hipótese foi rejeitada. A segunda e a terceira hipótese podem ser apenas parcialmente rejeitadas. / The objective of this study was to evaluate composite resin restoration polymerization stress development over the first 24 hours after polymerization, according to two methods of analysis of crack propagation. The influence of water storage on the magnitude of the stresses was also evaluated. The degree of conversion (DC) and modulus of elasticity (E) of the composite were determined at various time points. The null hypotheses of this study were: 1) The polymerization stress, DC and E do not change significant throughout the observation period, 2) the two methods of analysis of crack propagation provide similar results, 3) the stress values are not influenced by storage medium. Disks were made of soda-lime glass with 2 mm thickness, 12 mm in outside diameter with central bore of 4 mm in diameter. The perforations were treated with hydrofluoric acid and silane. The discs were randomized into three groups. In one of them, the discs were restored (Charisma Diamond, Heraeus Kulzer), and, the times after 10 min, 1, 2, 4, 8 or 24 hours (n = 10), the specimens received four Vickers indentations (9.8 N for 20 s) at 500m cavity margin. The second group went through the same process, but the discs were stored in water prior to being indented. Then, the length diagonal of the indentation and crack was measured in an optical microscope. The residual stress in the glass was calculated according to standard 4-01 (The Society of Materials Science, JSMS, Japan). The third group of discs were treated similarly, indented and stored in a desiccator for 24 hours before being restored. The cracks were measured before and after the restoration following the same time, and the stress calculated according to the formula described by Yamamoto et al. (Dent Mater, 2009). The DC was determined by near-infrared spectroscopy (n = 3). The E was obtained through the bend test conducted at three-points. Data were subjected by ANOVA / Tukey test ( = 0.05) and regression analysis. The polymerization stress, as well as DC and E values were increased over time. GC increased 28% between 10 minutes and 24 hours, and for an increase of 1.7 GPa to 6.3 GPa between 10 minutes and 24 hours. The polymerization stress increased 40% between 10 min and 24 hours to the standard 4.1 and 51% for the method of Yamamoto et al. The storage medium was statistically significant at the time of 4 hours. Thus, the first hypothesis was rejected. The second and third hypothesis may only be partially rejected.
|
26 |
Compósitos a base de dimetacrilatos ou silorano: caracterização da cinética e tensão de polimerização, com respectivos parâmetros determinantes; avaliação da rede polimérica formada por análise dinâmico-mecânica e estudo de extratos lixiv / Composites based on dimethacrylate or silorane: characterization of kinetics and polymerization stress, with their respective determining parameters; polymer network formed evaluation by dynamic mechanical analysis and leachable extracts studyLilyan Cardoso Yamasaki 28 September 2012 (has links)
OBJETIVO: caracterizar a interação entre tensão e cinética de polimerização e seus parâmetros determinantes, e avaliar a qualidade da rede polimérica e propriedades mecânicas de compósitos comerciais para dentes posteriores a base de dimetacrilato ou de silorano. A cinética de polimerização foi avaliada sob influência da intensidade da fonte de luz, da temperatura e da umidade. Por fim, o grau de conversão (GC) do compósito a base de silorano foi avaliado por espectroscopia e titulação. MÉTODOS: foram utilizados três compósitos de baixa contração: Kalore (KAL - GC America) e N´Durance (NDUR Septodont), a base de dimetacrilatos; e Filtek P90 (P90 - 3MESPE), a base de silorano. O EsthetX HD (EHD - Dentsply) foi utilizado como controle. A tensão de polimerização (TP) dos espécimes (n = 5; Ø = 5 mm; h = 1 mm, 10 min) foi obtida em máquina universal de ensaios mecânicos. A contração volumétrica (CVol) foi determinada em linômetro (n = 3; Ø = 6 mm; h = 1,5 mm; 10 min). O módulo de elasticidade em flexão (MeFlex) e a resistência à flexão (RFlex) (n = 10; 10 x 2 x 1 mm) foram obtidos através do teste de dobramento em três pontos (8 mm entre apoios; 0.5 mm/min). O GC e a taxa de polimerização (Rp) dos espécimes (n = 3; Ø = 6,5 mm; h = 0,8 mm) foram determinados por espectroscopia no NIR (banda em 6165 cm-1 para dimetacrilatos e em 4156 cm-1 e 4071 cm-1 para silorano). Para os testes acima descritos, a fotopolimerização foi realizada com 740 mW/cm2 x 27 s (Bluephase G2 Ivoclar). A temperatura de transição vítrea (Tg), a tangente de delta (tan delta), o grau de heterogeneidade e a densidade de ligações cruzadas de espécimes (n = 3; 15 x 3 x 1 mm) com o máximo de conversão foram obtidos em analisador dinâmico-mecânico. A análise dos extratos obtidos após imersão dos espécimes (Ø = 12 mm; h = 0,8 mm; 970 mW/cm2 x 30 s) em diclorometano foi realizada através de 1H-NMR para verificar monômeros residuais. A cinética de polimerização de espécimes (n = 3; Ø = 5,5 mm; h = 1 mm) de todos os materiais, fotopolimerizados com Acticure 4000 EXFO e filtro 320-500 nm, foi analisada sob variação de irradiância (3, 30 ou 200 mW/cm2) e de temperatura (23, 35 ou 60 °C) por espectroscopia no NIR (banda em 6165 cm-1 para dimetacrilatos e em 4156 cm-1 para silorano). A influência da umidade a 23, 35 ou 60 °C na cinética de polimerização foi verificada para Filtek P90 e EsthetX HD. Para auxiliar na identificação de bandas que possam ser utilizadas para o GC do Filtek P90, as conversões de bandas referentes a anéis epóxicos selecionadas com a caracterização espectroscópica (Mid-IR e NIR) de monômeros modelos e do Filtek P90 sem carga foram comparadas com os valores encontrados no teste de titulação ácido-base desses materiais. Os dados dos testes laboratoriais, quando necessário, foram submetidos à Anova e ao Teste de Tukey ( < 0,05). RESULTADOS: O EHD apresentou a maior TP, estatisticamente semelhante ao NDUR e maior que o KAL e o P90, estatisticamente semelhantes. A Cvol do EHD foi superior à do NDUR, e o P90 e o KAL obtiveram os menores valores, estatisticamente semelhantes. O P90 apresentou o maior MeFLex, sem diferença entre os outros materiais. O EHD obteve o maior valor de RFlex, e o KAL e o NDUR apresentaram os menores valores, sem diferença entre eles. O NDUR apresentou o maior GC, seguido do EHD e KAL, e o P90 apresentou o menor valor. O EHD apresentou a maior Tg, seguido de P90, KAL e NDUR. O NDUR e o P90 apresentaram, respectivamente, a maior e a menor tan delta. O NDUR e o KAL apresentaram a maior e a menor homogeneidade, respectivamente. O P90 apresentou a maior densidade de ligações cruzadas, sem diferença entre os outros compósitos. Diferentemente do EHD e do KAL, o P90 e o NUR não apresentaram lixiviação de monômeros residuais. O P90 mostrou cinética de polimerização semelhante aos compósitos dimetacrilatos, inclusive sob variação de irradiância e temperatura. A umidade aumentou ligeiramente o GCMáx do EHD a 23 e a 35 °C, porém a temperatura exerceu maior influência à 60° C. De uma maneira geral, a umidade não influenciou a cinética de polimerização do P90. Em Mid-IR, o P90 apresentou 60 % de conversão através da banda em 883 cm-1, próximo ao valor obtido com a titulação. Já em NIR, há conversão em duas bandas distintas: em 4156 cm-1 (42%) e em 4071 cm-1 (65%). CONCLUSÃO: o GC exerceu grande influência sobre os valores de TP. Altos valores de MeFlex e RFlex foram associados à alta densidade de ligações cruzadas. P90 e NDUR não apresentaram lixiviação de monômeros residuais. Um maior GC é obtido quando o compósito alcança alto valor de conversão até o ponto de vitrificação. O P90 mostrou comportamento semelhante aos compósitos baseados em dimetacrilatos quanto à cinética de polimerização, inclusive sob variação de irradiância e temperatura. De uma maneira geral, a umidade não exerceu grande influência na cinética de polimerização do P90 e do EHD. Como não se sabe a composição exata do Filtek P90, pode-se dizer apenas que a conversão deste material é cerca de 40 %. O teste de titulação precisa ser aperfeiçoado e são necessários estudos adicionais para se validar a metodologia FTIR X titulação utilizada. Como a composição monomérica exata do Filtek P90 não é conhecida, não foi possível precisar a conversão deste material com os métodos empregados, porém pode-se dizer que este material apresenta, no mínimo, cerca de 40 % de conversão, dada pela banda em 4156 cm-1. / OBJECTIVE: To characterize the interaction between polymerization kinetics and stress and its determining parameters, and evaluate polymer network quality and mechanical properties of commercial composites for posterior teeth based on dimethacrylate or silorane. Also, the influence of the intensity of the light source, temperature and humidity on the polymerization reaction was evaluated. Finally, the degree of conversion (DC) of the composite based on silorane was evaluated by spectroscopy and titration. METHODS: three \"low shrinkage\" composites were chosen: Kalore (KAL - GC America) and N\'Durance (NDUR - Septodont), based on dimethacrylates, and Filtek P90 (P90 - 3MESPE), based on silorane. EsthetX HD (EHD - Dentsply) was used as a control. Polymerization stress (PS) of samples (n = 5, Ø = 5 mm; h = 1 mm, 10 min) was obtained using a universal testing machine. Volumetric shrinkage (VS) was determined in a linometer (n = 3, Ø = 6 mm, h = 1.5 mm, 10 min). Elastic modulus (E) and flexural strength (FS) (n = 10; 10 x 2 x 1 mm) were obtained by three point bending test (8 mm between support, 0.5 mm/min). DC and polymerization rate (Rp) of specimen (n = 3, Ø = 6.5 mm, h = 0.8 mm) were determined by NIR spectroscopy (peak 6165 cm-1 for dimethacrylates and 4156 cm-1 and 4071 cm-1 for silorane). For these tests, photopolymerization was performed with 740 mW/cm2 x 27 s (Bluephase G2 - Ivoclar). Glass transition temperature (Tg), loss tangent (LT), degree of heterogeneity and crosslink density of specimens (n = 3, 15 x 3 x 1 mm) with maximum conversion was obtained in a dynamic mechanical analyzer. Analysis of extracts obtained after specimen immersion (Ø = 12 mm, h = 0.8 mm; 970 mW/cm2 x 30 s) in dichloromethane was carried out using 1H-NMR to determine residual monomers. Polymerization kinetics of specimens (n = 3; Ø = 5.5 mm, h = 1 mm) of all materials cured with Acticure 4000 - EXFO and 320-500 nm filter, was analyzed using different levels of irradiance (3, 30 or 200 mW/cm2) and temperature (23, 35 or 60 °C) by NIR spectroscopy (peak 6165 cm-1 for dimethacrylates and 4156 cm-1 for silorane). The influence of moisture at 23, 35 or 60 °C on polymerization kinetics was observed for Filtek P90 and EsthetX HD. To assist in the identification of peaks that can be used to calculate the conversion of Filtek P90, peaks related to epoxy rings selected with the spectroscopic characterization (Mid-IR and NIR) of model monomers and Filtek P90 (after filler extraction with acetone) were compared with the values found in acid-base titration test of these materials. Data were submitted to ANOVA and Tukey\'s test ( < 0.05). RESULTS: EHD showed the greatest TP, statistically similar to NDUR and greater than KAL and P90, statistically similar. EHD Cvol was superior to NDUR, and P90 and KAL had the lowest and statistically similar values. P90 had the highest MeFLex, with no difference between other materials. EHD had the highest RFlex value, and NDUR and KAL, the lowest one, with no difference between them. NDUR had the highest DC, followed by EHD and KAL, and P90 had the lowest value. EHD showed the highest Tg, followed by P90 and KAL and NDUR. NDUR and P90 showed respectively the highest and lowest LT. NDUR and KAL had the highest and the lowest homogeneity, respectively. P90 had the highest crosslink density, with no difference between other composites. Unlike EHD and KAL, NUR and P90 showed no leachable monomers. P90 showed similar polymerization kinetics to dimethacrylate composites, even with irradiation and temperature variation. Moisture slightly increased the DC of EHD at 23 and 35 °C, and temperature showed greater influence at 60 °C. In general, moisture did not influence P90 polymerization kinetics. P90 showed 60 % conversion in Mid-IR over the peak 883 cm-1, similar to the value obtained with titration. Two distinct peaks showed conversion in NIR: 4156 cm-1 (42 %) and 4071 cm-1 (65 %). CONCLUSION: DC had a great influence on PS values. Higher E and FS values were associated with higher crosslink density. NDUR and P90 showed no leachable monomers. A higher DC is obtained when the composite reaches high values of conversion before vitrification. P90 showed similar behavior to composites based on dimethacrylate regarding the polymerization kinetics, including under variation of irradiance and temperature. In general, moisture does not great influence P90 and EHD polymerization kinetics. As the exact composition of P90 is unknown, it was not possible to specify the conversion of this material with the methods employed, but it can be said that this material exhibits at least about 40 % conversion, provided by the peak 4156 cm-1.
|
27 |
Uso do hexafluorfosfato de difeniliodônio na polimerização radicalar fotoiniciada de metacrilatos / Diphenyliodonium hexafluorphosphate effect on the radical polymerization of methacrylatesOgliari, Fabrício Aulo 10 July 2009 (has links)
Made available in DSpace on 2014-08-20T14:30:12Z (GMT). No. of bitstreams: 1
Tese_Fabricio_Aulo_Ogliari.pdf: 990670 bytes, checksum: 3309e79bda50d0506e497074067ddfca (MD5)
Previous issue date: 2009-07-10 / The present investigation evaluated the effect of the diphenyliodonium hexafluorphosphate (DPIHFP) on the radical polymerization of methacrylates. Rate of polymerization from binary and ternary photoinitiation systems, performance of such systems in the presence of solvent and its effects on the bonding strength to bovine dentin were investigated. As a model adhesive resin, a blend of Bis-GMA, TEGDMA and HEMA (50/25/25 %wt) was prepared. Real-time degree of conversion was performed in a Fourier transform infrared spectrometer. To assess the photoinitiator system efficiency in a dental adhesive composition, the adhesion between the model resin and bovine
dentin was investigated using microtensile bond strength(μTBS). When CQ was used as photo-initiator, a slow polymerization reaction was observed. The addition of a
second component (onium salt or amine) increases the polymerization rate and conversion independent on the co-initiator concentration. Ternary photo-initiator system
showed an improvement on the polymerization rate of the dental adhesive model resin leading to high conversion in short photo-activation time.The addition of a solvent to the
monomer blends decreased the polymerization kinetics, directly affecting the rate of polymerization, delaying vitrification, and attenuating the Trommsdorf effect. The
introduction of DPIHFP displayed a strong increase in reaction kinetics, reducing the solvent inhibition effect. After one year of storage, the μTBS values of the group
CQ+EDAB+DPIHFP showed significantly higher bond strength(p<0.05) than CQ, CQ+DPIHFP and CQ+EDAB groups and no difference from commercial adhesive group. The ternary photoinitiation system with DPIHFP maintained increased bond strength to dentin of model self-etching adhesive systems after one year of aging / O objetivo do presente projeto foi avaliar o uso do hexafluorfosfato de difeniliodônio (DPIHFP) na polimerização radicalar de metacrilatos para aplicação odontológica. Para tal fim, foram considerados: aspectos relacionados ao potencial de
sensibilização do DPIHFP pela canforoquinona; velocidade da reação de polimerização em sistemas binários e ternários; efeito em sistemas contendo solvente orgânico; e,influência nos valores e estabilidade da resistência de união ao tecido dentinário. Uma resina adesiva modelo constituída de 50% de Bis-GMA, 25% de TEGDMA e 25% de HEMA em massa foi formulada e utilizada em todos os experimentos realizados. Para a
avaliação da cinética de conversão foram realizadas análises em espectroscopia no infravermelho em tempo real (RT-FTIR).Para a avaliação da resistência de união em dentina bovina, foram realizados ensaios de resistência de união à microtração na
configuração de palitos, após 24 horas e 1 ano de realização das restaurações. Quando CQ foi utilizada como fotoiniciador, uma lenta reação de polimerização foi observada, sendo que a adição do DPIHFP como co-iniciador promoveu um aumento na
reatividade do sistema, independentemente da concentração utilizada. A utilização de DPIHFP no sistema de fotoiniciação promoveu um aumento expressivo na reatividade do sistema, aumentando a taxa de polimerização máxima e o grau de conversão final do material. Adicionalmente, o DPIHFP reduziu o efeito inibitório provocado pela presença de solvente durante a polimerização, mantendo as taxas de polimerização
semelhantes ao controle sem solvente. Quando o DPIHFP foi introduzido em um adesivo odontológico, foi observado um aumento significativo dos valores de resistência de união, sendo que estes valores mantiveram-se constantes em avaliação após 1 ano
|
28 |
Translucency and degree of conversion of resin cement with different thickness of full contour zirconiaSupornpun, Noppamath January 2015 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Background: Traditionally, zirconia has been used as a core material for allceramic
crowns that are later covered by a more esthetic veneering layer. Recently, new
zirconia materials with higher translucency commonly referred to as the “full contour
zirconia” have been introduced with the aim to allow dentist to fabricate entire allceramic
crown from the material with acceptable esthetic and mechanical functions
without the need for veneering. However, there is little information in the literature
regarding the translucency of full contour zirconia and the degree of conversion of resin
cement underneath the full contour zirconia. Objectives: 1) To investigate the
translucency parameter (TP) of recently marketed full contour zirconia and compare that
to traditional zirconia and lithium disilicate glass ceramic (LDGC) at different
thicknesses. 2) To evaluate the degree of conversion (DC) of the resin cement through
different thicknesses of the full contour zirconia, traditional zirconia and LDGC.
Alternative hypothesis: The new generation zirconia at the clinically recommended
thickness has lower translucency than that of LDGC and higher than that of non-veneered
traditional zirconia. In addition, DC of resin cement under full contour zirconia is lower
than that of LDGC and higher than that of traditional zirconia. Methods: 150 ceramic
specimens (12 x12 mm with thickness of 1-2 mm for LDGC and Zirconia) were divided
into 6 groups according to the type of material, as follow: LDGC (IPS e-max CAD),
Traditional Zirconia (CAP QZ), full contour zirconia (CAP FZ, Zirlux, Bruxzir, KDZ
Bruxer). The TP for materials at various thicknesses were measured by a
spectrophotometer (CM-2600D). The DC of the light curing resin cement (Variolink II)
underneath the ceramic disks was measured by FTIR. Result: All full contour zirconia
has lower translucency parameter and light transmission than LDGC. The translucency
parameter decreases with increasing thickness of any type of ceramic. There were no
significant differences in the degree of conversion of resin cement among the type of
ceramic disc, except Bruxzir. The correlation of TP between various thicknesses and the
types of ceramic materials was established by a regression analysis.
|
29 |
Evaluation of multiple and single emission peak light emitting diode light curing units effect on the degree of conversion and microhardness of resin-based pit and fissure sealantAlqahtani, Saleh Ali M. January 2017 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Objective: The objective was to assess a multiple emission peak light-emitting-diode
(LED) light-curing unit (LCU) by measuring the polymerization efficiency through the
degree of conversion (DC) and Knoop microhardness (KHN) of a resin-based pit and
fissure sealant at various light curing times and two distances compared to a single
emission peak LED LCU.
Method: Sixty disks of resin-based pit and fissure sealant (Delton, DENTSPLY, York, PA)
samples (6x1mm) were fabricated (n=5/LCU/group). Prepared samples were polymerized
using 10, 20 and 40 second curing time at 2 or 4 mm curing distances. The irradiance and
radiant exposure received on the top/bottom surfaces of the samples were measured using
the Managing Accurate Resin Curing-Resin Calibrator (MARC-RC) system. The samples
were stored at 37°C for one hour. Then, the DC (n=3/surface) and KHN (n=5/surface)
measurements were collected on the top and bottom surfaces using Attenuated Total
Reflection-Fourier Transform Infrared Spectroscopy (ATR-FTIR) and a microhardness
tester (Instron) utilizing 25-gm at 10 seconds dwell time, respectively. Multiple-way
ANOVA was performed followed by Tukey test (α=0.05).
Result: The irradiance from the multiple emission peak LED LCU was significantly higher
than the single emission peak LED LCU (1312.6 and 768.3 mW/cm2) respectively.
Moreover, the multiple emission peak LED LCU displayed significantly higher DC
(82.5%) and microhardness (26.2 KHN) compared to the single emission peak LED LCU
(75.5% DC and 21.2 KHN) when curing samples at 2 and 4 mm curing distances assessed
using 10, 20 and 40-second curing times. The 10 second cure at 4 mm showed significantly
lower DC and KHN values compared to the other groups.
Conclusion: The multiple emission peak LED LCU demonstrated significantly higher
irradiance, DC and KHN compared to the single emission peak LED LCU on a resin-based
pit and fissure sealant at 2 and 4 mm curing distances and 10, 20 and 40 second curing
times. Therefore, the multiple emission peak LED LCU performed higher than the single
emission peak LED LCU.
|
30 |
Caracterização térmica, grau de conversão, resistência à flexão e dureza de compósitos comerciais tratados termicamente / Thermal characterization, degree of conversion, flexural strength and Knoop hardness of heat treated commercial compositesMiyazaki, Caroline Lumi 03 August 2010 (has links)
Visando otimizar as propriedades químicas e mecânicas de compósitos de uso direto aplicados na forma indireta, associados a tratamentos térmicos experimentais (TT), torna-se necessária uma caracterização térmica que permita a determinação de uma temperatura de TT segura (abaixo da temperatura de início de perda de massa). Assim, a primeira etapa deste estudo consistiu em caracterizar termicamente dez compósitos comerciais (Z100, Filtek Z250, Z350 e Supreme XT- 3M ESPE, Esthet-X e TPH Spectrum Dentsply, Charisma Heraeus Kulzer, Tetric Ceram Ivoclar Vivadent, Herculite XRV e Point 4 - Kerr), fotoativados pelo método contínuo (C) e pulse-delay (PD) (20 J.cm-2), por termogravimetria (TG) (n=1) e calorimetria exploratória diferencial (DSC) (n=3). Foram escolhidas duas temperaturas de TT: 100 e 170°C, aplicadas por 10 min, 24h após a fotoativação. A partir disto, avaliaram-se: 1) o grau de conversão (GC), por espectroscopia FT-Raman (n=3); 2) a resistência à flexão em três pontos (RF) (n=10); e 3) a dureza Knoop (KHN) para as faces topo e base (n=3) de quatro destes compósitos (Filtek Z250 e Supreme XT, Esthet-X e Point 4), após diferentes condições: imediatamente, 1h, 6h e 24h após a fotoativação e 24h após fotoativação seguida de TT a 100 ou 170°C. Os dados obtidos foram submetidos à análise de variância e ao teste de Tukey (nível de significância de 5%). Quanto ao GC (%), houve significância estatística para o fator material (p=0,000): Point 4 (68,42) > Z250 (63,05) = Esthet-X (61,69) > Supreme (54,27); condição (p=0,000): TT170 (73,20) = TT100 (73,58) > 24h (62,60) = 6h (60,18) > 1h (55,10) = imediato (53,66); e ativação (p=0,006): C (62,97) > PD (60,75). Também foram significantes as interações material × condição (p=0,007) e material × condição × ativação (p=0,013). Para a RF (MPa), foram encontradas significâncias estatísticas para os fatores material (p=0,000): Z250 (165,48) > Supreme (153,96) > Point 4 (131,30) = Esthet-X (128,06); e condição (p=0,000): TT170 (194,56) > TT100 (182,91) > 24h (150,88) > 6h (131,79) > 1h (111,77) > imediato (96,30); assim como para as interações: ativação × condição (p=0,000), material × condição (p=0,000) e material × ativação × condição (p=0,000). Para a dureza, foram encontradas significâncias estatísticas para os fatores: materialativação (p=0,000): Supreme C (82,46) > Supreme PD (80,29) = Z250 C (77,46) > Z250 PD (74,30) > Esthet-X C (69,17) > Esthet-X PD (65,67) > Point 4 C (57,21) = Point 4 PD (56,71); condição (p=0,000): TT170 (81,35) > TT100 (73,72) > 24h (70,36) > 6h (67,92) > 1h (64,99) > imediato (64,12) e face (p=0,000): topo (71,40) > base (69,40); assim como para as interações: material-ativação × face (p=0,011), material-ativação × condição (p=0,000) e face × condição (p=0,000). A partir dos resultados obtidos, pôde-se concluir que os TTs experimentais propostos foram capazes de aumentar as propriedades estudadas, sendo, de maneira geral, os resultados obtidos com 170°C melhores do que os com 100°C, e ambos melhores do que as demais condições. / Aiming to optimize chemical and mechanical properties of direct composites applied in an indirect way, with an association to experimental heat treatments (TT), it is necessary a thermal characterization, in a way to determine a safe temperature for the TT (below the significant mass loss temperature). Thus, the first step of this study was to perform the thermal characterization of ten commercial composites (Z100, Filtek Z250, Z350 and Supreme XT 3M-ESPE, Esthet-X and TPH Spectrum Dentsply, Charisma Heraeus Kulzer, Tetric Ceram Ivoclar Vivadent, Herculite XRV and Point 4 - Kerr) photoactivated by continuous (C) and pulse-delay (PD) methods (20 J.cm-2), by thermogravimetry (TG) (n=1) and differential scanning calorimetry (DSC) (n=3). After that, two temperatures were chosen for the TT: 100 and 170°C, which were applied for 10 min, 24h after photoactivation. Thus, some properties were evaluated for four composites (Filtek Z250 and Supreme XT, Esthet- X and Point 4): 1) degree of conversion (GC) by FT-Raman spectroscopy (n=3); 2) three-point bending test (RF) (n=10); and 3) Knoop hardness (KHN) for top and bottom surfaces (n=3). The conditions were: immediately, 1h, 6h and 24h after photoactivation and 24h after photoactivation followed by TT at 100 or 170°C. Data were analyzed by ANOVA and Tukeys test (level of significance of 5%). In relation to GC (%), there were statistical significance for the factors material (p=0.000): Point 4 (68.42) > Z250 (63.05) = Esthet-X (61.69) > Supreme (54.27); condition (p=0.000): TT170 (73.20) = TT100 (73.58) > 24h (62.60) = 6h (60.18) > 1h (55.10) = immediately (53.66); and activation (p=0.006): C (62.97) > PD (60.75); and for the interactions: material × condition (p=0.007) and material × condition × activation (p=0.013). For RF (MPa), statistical significance were found for the factors material (p=0.000): Z250 (165.48) > Supreme (153.96) > Point 4 (131.30) = Esthet-X (128.06); and condition (p=0.000): TT170 (194.56) > TT100 (182.91) > 24h (150.88) > 6h (131.79) > 1h (111.77) > immediately (96.30); and also for the interactions: activation × condition (p=0.000), material × condition (p=0.000) and material × activation × condition (p=0.000). For KHN, statistical significance were found for the factors material-activation (p=0.000): Supreme C (82.46) > Supreme PD (80.29) = Z250 C (77.46) > Z250 PD (74.30) > Esthet-X C (69.17) > Esthet-X PD (65.67) > Point 4 C (57.21) = Point 4 PD (56.71); condition (p=0.000): TT170 (81.35) > TT100 (73.72) > 24h (70.36) > 6h (67.92) > 1h (64.99) > immediately (64.12), and face (p=0.000): top (71.40) > bottom (69.40); as for the interactions: material-activation × face (p=0.011), material-activation × condition (p=0.000) and face × condition (p=0.000). By the results, it could be concluded that both proposed experimental TTs were capable of increasing the studied properties, with, in a general way, 170°C generating better mechanical properties than 100°C, and both better than the other conditions.
|