• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 116
  • 49
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 168
  • 98
  • 76
  • 44
  • 35
  • 35
  • 33
  • 32
  • 30
  • 29
  • 29
  • 28
  • 27
  • 26
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Eficácia da ação antimicrobiana de soluções químicas - hipoclorito alcalino e mamona (Ricinus communis) - frente a micro-organismos específicos / Efficacy of antimicrobial action of chemical solutions - alkaline hypochlorite and castor oil (Ricinus communis) - against specific microorganisms

Salles, Marcela Moreira 27 June 2013 (has links)
O objetivo deste trabalho foi avaliar, por meio de estudo laboratorial e clínico, a eficácia de soluções de hipoclorito alcalino (0,25% e 0,5%) e à base de mamona (Ricinus communis) a 10% quanto à ação antimicrobiana frente a micro-organismos específicos, por meio da contagem de Unidades Formadoras de Colônias (UFC). No estudo laboratorial, a partir de matrizes metálicas quadrangulares (10 x 2 mm), foram confeccionados 360 corpos de prova de resina acrílica termopolimerizável (Lucitone 550), os quais foram esterilizados em micro-ondas (650W, por 6 minutos), contaminados com cepas de Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans, Bacillus subtilis, Escherichia coli, Streptococcus mutans, Enterococcus faecalis e Candida glabrata e imersos (20 minutos) em soluções higienizadoras (n=10): Grupo A - Hipoclorito de sódio 0,25%; Grupo B - Hipoclorito de sódio 0,5%; Grupo C - Solução de mamona a 10%; Grupo D (Controle positivo) - solução salina e Grupo E (Controle negativo) - sem contaminação e imerso em solução salina (n=5). Em seguida, foram lavados em solução salina e imersos em meio de cultura líquido (Letheen), a partir do qual foram obtidas diluições seriadas (100 e 10-3), as quais foram semeadas em meios de cultura seletivos. Após incubação a 37ºC por 24 horas, as colônias foram contadas e os valores de UFC/mL calculados. No estudo clínico, 64 pacientes, usuários de próteses totais, foram orientados a escovar suas próteses (escova Bitufo® e sabonete líquido neutro) três vezes ao dia e imergí-las (20 minutos), uma vez ao dia, em soluções: Solução 1 - Hipoclorito de sódio 0,25%; Solução 2 - Hipoclorito de sódio 0,5%; Solução 3 - Solução de mamona a 10% e Solução 4 - solução salina (controle). De acordo com uma sequência aleatorizada, cada solução foi utilizada por 7 dias, com um período de wash out entre elas. A avaliação da ação antimicrobiana foi realizada antes dos uso dos produtos (Baseline) e após os 7 dias de uso de cada uma das soluções, por meio da contagem de Unidades Formadoras de Colônias (UFC) de Streptococcus mutans, Candida spp. e gram negativos. Para coleta do biofilme, cada prótese total superior foi colocada em placa de Petri e a superfície interna escovada (escova Tek e solução salina) por 2 minutos, sendo a suspensão transferida para tubo de ensaio. Após diluições decimais (100 até 10-3), alíquotas de 50 &mu;L foram semeadas em placas de Petri contendo Mitis Salivarius Agar Base, Chromagar® Candida e Mac Conkey Agar para a detecção de Streptococcus mutans, Candida spp. ou gram negativo, respectivamente. Após incubação a 37ºC (em microaerofilia durante 48-72 horas para grupo mutans e aerobiose durante 48 horas para Candida spp. e gram negativo), de acordo com morfologia típica, o número de colônias características foi mensurado e o número de UFC/mL calculado. Os dados obtidos foram transformados de acordo com a fórmula log10 (UFC+1) e analisados estatisticamente por meio do teste t de Student (&alpha;=0,05), para a análise laboratorial, e teste de Friedman (&alpha;=0,05), para a análise clínica. Os resultados mostraram que, no estudo laboratorial, as soluções de hipoclorito de sódio (0,25% e 0,5%) eliminaram completamente todos os micro-organismos. A solução de mamona eliminou completamente B. subtilis, não apresentou efeito sobre E. faecalis e apresentou ação antimicrobiana moderada frente às demais cepas, havendo redução significante (p < 0,05) do número de UFC quando comparado com o grupo D (controle positivo). No estudo clínico, houve diferença significante entre as soluções (P < 0,001), sendo que o hipoclorito de sódio a 0,5% apresentou ação efetiva sobre todos os micro-organismos avaliados (Candida spp., S. mutans e gram negativos); o hipoclorito de sódio 0,25%, ação efetiva sobre S. mutans e moderada sobre Candida spp. e gram negativos, e a solução de mamona, ação efetiva sobre S. mutans e moderada contra Candida spp. A espécie de Candida mais frequentemente isolada foi C. albicans, seguida pelas espécies C. tropicalis e C. glabrata. Concluiu-se que a solução de hipoclorito de sódio 0,5% foi a mais efetiva, apresentando ação antimicrobiana sobre ambos os biofilmes (in vitro e in vivo), seguida pela solução de hipoclorito de sódio 0,25% que apresentou ação antimicrobiana sobre o biofilme in vitro e sobre S. mutans (biofilme in vivo). A solução de mamona (10%) foi a menos efetiva, apresentando ação antimicrobiana sobre B. subtilis (biofilme in vitro) e S. mutans (biofilme in vivo). / The objective of this study was to evaluate, through laboratory and clinical study, the efficacy of alkaline hypochlorite solutions (0.25% and 0.5%) and 10% castor oil solution (Ricinus communis) about the antimicrobial action against specific microorganisms, by counting the number of Colony Forming Units (CFU). In the laboratory study, 360 denture base acrylic resin specimens (Lucitone 550) were obtained from square metal matrix (10 mm x 2 mm), which were sterilized with microwave (650W, for 6 minutes), contaminated with Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans, Bacillus subtilis, Escherichia coli, Streptococcus mutans, Enterococcus faecalis and Candida glabrata and immersed (20 minutes) in the hygiene solutions (n = 10): Group A - 0.25% Sodium Hypochlorite; Group - B - 0.5% Sodium hypochlorite; Group C - 10% Castor oil solution; Group D (Positive Control) - saline and Group E (Negative Control) - no contamination and immersed in saline (n = 5). The specimens were washed in saline solution and immersed in liquid culture medium (Letheen), from which were obtained serial dilutions (100 to 10-3) and seeded into selective solid media. After incubation at 37º C for 24 hours, the colonies were counted and the values of CFU/mL calculated. In the clinical study, 64 complete denture wearers were instructed to brush their dentures (Bitufo ® brush and liquid neutral soap) three times a day and to soak them (20 minutes), once a day, in the solutions: Solution 1 - 0.25% Sodium Hypochlorite; Solution 2 - 0.5% Sodium hypochlorite; Solution 3 - 10% Castor oil and Solution 4 - saline (control). According to a randomized sequence, each solution was used for 7 days, with a period of wash out between them. The evaluation of the antimicrobial action was performed before the use of the products (Baseline) and after 7 days after using each solution, by counting the Colony Forming Units (CFU) of Streptococcus mutans, Candida spp. and gram negative. For collection of the biofilm, each upper complete denture was placed in a Petri dish, the internal surface was brushed with saline solution for 2 minutes and the suspension was transferred to a test tube. After decimal dilutions (100 to 10-3), aliquots of 50 uL were seeded inside Petri dishes containing Mitis Salivarius Agar Base, Candida Chromagar ® and Mac Conkey Agar for the detection of Streptococcus mutans, Candida spp. or gram negative, respectively. After incubation at 37° C (in microaerophilic conditions for 48-72 hours for mutans and aerobiosis for 48 hours for Candida spp. and gram negative), in accordance with characteristic morphology, the number of characteristic colonies was countedand the number of CFU/ml calculated. Data were processed following transformation into the formula log10 (CFU +1) and statistically analyzed using the Student t test (&alpha; = 0.05) for laboratory analysis, and Friedman test (&alpha; = 0.05), for clinical analysis. The results showed that, in the laboratory study, sodium hypochlorite (0.25% and 0.5%) eliminated completely all microorganisms. The Castor oil solution eliminated B. subtilis, had no effect on E. faecalis and showed moderate antimicrobial activity against other strains, with a significant reduction (p <0.05) in the number of CFU compared with group D (positive control). In the clinical study, there was significant difference between the solutions (P <0.001), and 0.5% sodium hypochlorite had effective action on all evaluated microorganisms (Candida spp., S. mutans and gram negative); 0.25% sodium hypochlorite had effective action on S. mutans and moderate on Candida spp. and gram negative, and the castor oil solution had effective action on S. mutans and moderate against Candida spp. . The Candida species most often isolated was C. albicans, followed by the species C. tropicalis and C. glabrata. It was concluded that the solution of 0.5% sodium hypochlorite was the most effective presenting antimicrobial action on both biofilms (in vitro and in vivo), followed by 0.25% sodium hypochlorite solution that showed antimicrobial activity on biofilms in vitro and on S. mutans (biofilm in vivo). The 10% castor oil was less effective, with antimicrobial action on Bacillus subtilis (biofilm in vitro) and S. mutans (biofilm in vivo).
122

Efetividade da irradiação por microondas na desinfecção de próteses totais contaminadas por diferentes espécies de Candida isoladas de pacientes HIV positivo

Sanitá, Paula Volpato [UNESP] 26 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-26Bitstream added on 2014-06-13T19:16:49Z : No. of bitstreams: 1 sanita_pv_me_arafo.pdf: 1236296 bytes, checksum: 793fd4710489b2253297ebbc15835736 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A estomatite protética associada à Candida é a forma mais comum de candidíase oral e também uma das infecções oportunistas mais encontradas em pacientes infectados por HIV. Atualmente, a desinfecção de próteses totais através da irradiação por microondas tem sido recomendada para tratamento e prevenção da estomatite protética, tanto em indivíduos saudáveis, quanto em pacientes imunocomprometidos. O presente estudo avaliou a efetividade da irradiação por microondas na desinfecção de próteses totais simuladas contaminadas com 5 diferentes espécies do microorganismo Candida (C. albicans, C. glabrata, C. dubliniensis, C. tropicalis e C. krusei) isoladas de culturas padrão e de pacientes HIV positivo. Para isso, próteses totais simuladas foram confeccionadas, esterilizadas por meio de óxido de etileno e individualmente inoculadas com os microorganismos avaliados. Após o período de incubação (48 horas a 37°C), as próteses foram submetidas à irradiação por microondas a 650W durante 3 minutos. Próteses totais não irradiadas foram utilizadas como controle positivo. A seguir, uma alíquota de 25 æL da solução resultante das diluições seriadas de 10-1 a 10-4 foi semeada em placas de Petri em duplicata e todas as placas foram incubadas por 48 horas a 37°C. As colônias foram quantificadas em ufc/mL. Para verificar a efetividade da desinfecção por microondas a longo prazo, as próteses totais irradiadas foram incubadas a 37°C por 7 dias. Os resultados obtidos foram analisados estatisticamente pelos testes de ANOVA e de Tukey (a=0.05). As próteses totais contaminadas com todas as espécies de Candida avaliadas demonstraram esterilização após irradiação por microondas durante 3 minutos a 650W. Todas as próteses do grupo controle positivo demonstraram crescimento microbiológico após incubação nas placas de Petri. / The most common form of oral candidiasis is Candida-associated denture stomatitis. Oral candidiasis is also a frequent manifestation of HIV infection. Microwave disinfection of complete dentures has been recommended to treat and prevent denture stomatitis in non-immune compromised patients. The present study evaluated the effectiveness of microwave irradiation on the disinfection of simulated complete dentures inoculated with ATCC and HIV isolates of 5 species of Candida (C. albicans, C. glabrata, C. dubliniensis, C. tropicalis and C. krusei). Simulated complete dentures were made, sterilized and individually inoculated with the tested microorganisms. After incubation for 48 hours at 37°C, dentures were submitted to microwave irradiation (650W for 3 minutes). Non-irradiated dentures were used as positive controls. Replicate aliquots of suspensions were plated at dilutions 10-1-10-4 and incubated for 48 hours at 37°C. Colonies counts (cfu/mL) of each plate were quantified. To verify the long-term effectiveness of microwave disinfection, dentures were incubated at 37°C for 7 days. Data were analyzed with two-way ANOVA and Tukey HSD tests (a=0.05). The results indicated that complete dentures contaminated with all Candida yeasts showed sterilization after microwave irradiation for 3 minutes at 650W. All control dentures showed microbial growth on the plates. The cfu/mL for C. glabrata was significantly higher than those of C. albicans, C. dubliniensis and C. tropicalis whereas the cfu/mL for C. krusei was significantly lower. The cfu/mL for clinical isolates was significantly higher than those of ATCC yeasts. Microwave irradiation for 3 minutes at 650W resulted in sterilization of complete dentures contaminated with the 5 species of Candida isolated from HIV-infected patients.
123

Análise da influência dos sistemas de retenção para overdentures implanto-retidas e da espessura e resiliência da fibromucosa na distribuição interna das tensões, através do método de elementos finitos bidimensional

Barão, Valentim Adelino Ricardo [UNESP] 18 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-18Bitstream added on 2014-06-13T20:18:40Z : No. of bitstreams: 1 barao_var_me_araca.pdf: 2925422 bytes, checksum: 91ac65727dd1aa72a0e59c81f8a2faa1 (MD5) / Os implantes osseointegrados quando submetidos a cargas funcionais transmitem as tensões geradas diretamente ao osso. Dessa forma, muitas falhas na osseointegração estão ligadas ao excesso de carga sobre o implante. No caso de próteses implanto-retidas e muco-suportadas, outro importante fator que pode contribuir para uma maior ou menor incidência de tensões ao nível do implante reside na diferença de resiliência entre a fibromucosa e o implante. No tratamento com overdentures, este mecanismo de transmissão e distribuição não está bem documentado. Dessa forma, o objetivo desse estudo foi analisar, através do Método de Elementos Finitos bidimensional, a influência dos sistemas de retenção para overdentures implanto-retidas e da espessura e resiliência da fibromucosa na distribuição interna de tensões. Foram construídos em computador, através do programa Auto CAD, modelos matemáticos representativos de cortes frontais da mandíbula, sendo modelo A (controle), mandíbula edêntula suporte de prótese total convencional; modelo B, mandíbula edêntula suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico; modelo C, mandíbula edêntula suporte de overdenture com dois attachments esféricos do tipo o’ring em dois implantes independentes e modelo D, mandíbula edêntula suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico associados a dois attachments esféricos distais do tipo o’ring. Em todos os modelos, a fibromucosa assumiu três características de espessura (1, 3 e 5mm) nas resiliências dura, resiliente e flácida, respectivamente, através da variação do módulo de elasticidade da fibromucosa. Para análise, simulada no programa Ansys, os modelos foram fixados nas laterais direita e esquerda, permitindo deflexão da mandíbula. Foi aplicada... / Implants overload is the main factor responsible for osseointegration loss since functional loads are distributed directly to the bone. In addition, the difference between mucosa and implant mobility influence stress level, mainly in prosthesis supported by implant and mucosa. In overdenture treatments, the mechanisms of stress transmission and distribution induced by attachments system are not completely understood as literature concerning the influence of several biomechanical factors remains inconclusive. Thus, the aim of this study was to evaluate the effect of different mucosa thickness and resilience on stress distribution of implant-retained overdentures with different attachment systems using a two-dimensional Finite Element Analysis (FEA-2D). Representative models of edentulous mandible were constructed on AutoCAD software; Group A (control), a model of edentulous mandible supporting a complete denture; Group B, a model of edentulous mandible supporting an overdenture retained by two splinted implants connected with bar-clip system; Group C, a model of edentulous mandible supporting an overdenture retained by two unsplinted implants with o’ring system; Group D, a model of edentulous mandible supporting an overdenture retained by two splinted implants connected with bar-clip system associated with two distally o’ring system. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5mm) in the resiliences hard, resilient and soft, respectively, through different mucosa’s Young modulus. Evaluation was performed on Ansys software, with both right and left sides of models fasttened to allow mandibular bending. A vertical load of 100N was applied on lower central incisive teeth, and the principal stress was used as analysis criteria. Overall, group A showed the lowest stress values followed by groups C, D and B both in general stress maps as in the evaluation of... (Complete abstract click electronic access below)
124

Caracterização de materiais experimentais e comerciais para reembasamento imediato por meio de análise de propriedades físico-químicas e mecânicas

Reis, José Mauricio dos Santos Nunes [UNESP] 03 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-03Bitstream added on 2014-06-13T19:44:47Z : No. of bitstreams: 1 reis_jmsn_dr_arafo.pdf: 1310753 bytes, checksum: 17bd719b0c46c00b10cbd2db022db42a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou o comportamento exotérmico de 5 resinas rígidas para reembasamento imediato, duas experimentais (E1 e E2) à base de agentes de ligação cruzada (etileno glicol dimetacrilato e 1,4-butanediol dimetacrilato) e três comerciais (Kooliner-K, New Truliner-NT, Tokuyama Rebase II-TR II), bem como o grau de conversão (GC), a sorção (Sor) e a solubilidade (Sol) em água, a contração linear de polimerização (CLP), as propriedades viscoelásticas e a resistência à flexão desses materiais e de uma resina para base de prótese (Lucitone 550-L). Foi avaliada, ainda, a resistência de união (RU) entre os reembasadores e a resina de base. O comportamento exotérmico foi avaliado (n=4) com termopar tipo K inserido no interior das resinas, em matriz circular (60 x 2,0 mm), e mantido até a polimerização. O GC (%) foi avaliado (n=5) por espectroscopia de infravermelho por transformadas de Fourier (32 leituras; resolução 4,0 cm-1). A Sor e a Sol (μg/mm3) foram mensuradas (n=5) seguindo as recomendações da ISO 1567. A CLP (%) foi avaliada (n=10), em projetor de perfil (Nikon 6C), em corpos-de-prova circulares (50 x 0,5 mm). Para avaliar as propriedades viscoelásticas, corpos-de-prova (40 x 10 x 3,3 mm) foram submetidos (n=2) à análise térmica dinâmico-mecânica (DMTA) em diferentes intervalos de temperatura (ciclos). O módulo de armazenamento (E’) e o amortecimento mecânico (tan δ) a 37ºC foram registrados durante o primeiro e último ciclo da DMTA. A temperatura de transição vítrea (Tg) foi mensurada somente no último ciclo da DMTA. Os ensaios mecânicos de flexão (0,5 mm/min) foram realizados (n=10) em corpos-de-prova (64 x 10 x 3,3 mm) intactos ou reembasados e a resistência (MPa) calculada na tensão máxima (RFM) e no limite de proporcionalidade (RFLP). Para avaliar a RU (MPa) entre os materiais, 60 cilindros (20 x 20 mm) da resina L foram processados... / This study evaluated the exothermic behavior, degree of conversion (DC), water sorption (WSor), water solubility (WSol), linear polymerization shrinkage (LPS), viscoelastic properties and flexural strength of 5 hard chairside reline resins, two experimental (E1 and E2) based on crosslinking agents (ethylene glycol dimethacrylate and 1,4-butanediol dimethacrylate) and three commercially available (Kooliner-K, New Truliner-NT and Tokuyama Rebase II-TR II), and one heat-polymerized denture base resin (Lucitone 550-L). The shear bond strength (SBS) between the denture base resin and the reline materials was also evaluated. The exothermic behavior of circular specimens (60 x 2.0 mm) during polymerization was assessed (n=4) using a type K thermocouple. The DC (%) was measured (n=5) by Fourier Transformed infrared-attenuated total reflectance (FTIR-ATR) spectroscopy (32 scans; resolution of 4.0 cm-1). WSor and Wsol (μg/mm3) were determined (n=5) according to the recommendation stated in ISO 1567. The LPS (%) was measured (n=10) in circular specimens (50 x 0.5 mm) using a perfilometer (Nikon 6C). The viscoelastic properties of the specimens (40 x 10 x 3.3 mm) were evaluated (n=2) by dynamical-mechanical thermal analysis (DMTA) under different temperature ranges (runs). Values of storage modulus (E’) and loss tangent (tan δ) at 37ºC were obtained from the first and last runs. The glass transition temperature (Tg) was only measured from the last run. Ultimate flexural strength (UFS - MPa) and flexural strength at the proportional limit (FSPL - MPa) were determined (n=10) by three-point test (0.5 mm/min) using intact and relined specimens (64 x 10 x 3.3 mm). To evaluate the SBS between the materials, 60 cylinders (20 x 20 mm) of the denture base resin L were processed, relined (3.5 x 5.0 mm) and submitted to shear testing (0.5 mm/min). Data were analyzed by ANOVA and Tukey... (Complete abstract click electronic access below)
125

Efeito da incorporação de agentes antifúngicos na resistência à tração e porosidade de materiais resilientes temporários para base de próteses / Effect of incorporation of antifungal agents on the ultimate tensile strength and porosity of temporary soft denture liners

Jozely Francisca Mello Lima 10 February 2017 (has links)
Este estudo investigou a resistência à tração (ou limite de resistência à tração- LRT) e a porosidade de reembasadores resilientes temporários modificados por concentrações inibitórias mínimas (CIMs) de agentes antifúngicos para o biofilme Candida albicans (SC5314). Para os testes de LRT, corpos de prova em forma de halteres (n=7) com uma área transversal de 33 mm x 6 mm x 3 mm foram produzidos para os materiais resilientes (Trusoft e Softone) sem (controle) ou com incorporação de cinco fármacos em suas CIMs: nistatina- 0,032 g; diacetato de clorexidina- 0,064; cetoconazol- 0,128 g; miconazol- 0,256 g; itraconazol-0,256 g (grama de fármaco por grama de pó de material resiliente). Após a plastificação, as amostras foram imersas em água destilada a 37°C durante 24 h, 7 e 14 dias e, então, testadas em tensão em uma máquina universal de ensaios (EMIC DL-500 MF) a 40 mm/min. A porosidade foi mensurada por absorção de água, com base na exclusão do efeito plastificante. Inicialmente, determinou-se por isotermas de sorção, que a solução de armazenagem adequada para os corpos de prova (65 mm x 10 mm x 3,3 mm) de ambos os materiais foi o cloreto de cálcio anidro a 50% (S50). Assim, o fator de porosidade (FP) foi calculado para os grupos de estudo (n=10) formados por espécimes sem (controle) ou com incorporação de fármaco em suas CIMs (nistatina, clorexidina ou cetoconazol) após a armazenagem em água destilada ou S50 por 24 h, 7 e 14 dias. Os dados de resistência à tração (MPa) e percentagem de alongamento (%) foram submetidos à ANOVA de 3 fatores seguida pelo teste de Tukey (=0,05). Os dados de porosidade foram analisados estatisticamente por ANOVA de medidas repetidas para 4 fatores e teste de Tukey (=0,05). Ao final de 14 dias, a resistência à tração para ambos os materiais foi significativamente menor nos grupos modificados pelo miconazol e itraconazol em relação aos outros grupos (P<0,0001), que não mostraram diferenças significativas entre si (P>0,05). Após 7 e 14 dias em água, o miconazol e itraconazol adicionados a ambos os materiais resultaram em percentagens significativamente menores de alongamento em comparação com os outros fármacos e ao controle (P<0,0001), que foram semelhantes entre si (P>0,05). O cetoconazol não resultou em alterações significativas no FP para ambos os materiais resilientes em água ao longo de 14 dias (P>0,05). Em comparação aos controles, houve aumento dos FPs do Softone e Trusoft aos 14 dias de imersão em água somente após a adição de nistatina e clorexidina e de clorexidina, respectivamente (P<0,05). Ambos os materiais não apresentaram alterações significativas no FP em até 14 dias de imersão na S50, em comparação aos controles (P>0,05). Em todas as condições experimentais, os FPs do Softone e Trusoft foram significativamente menores quando imersos em S50 em comparação com a água destilada (P<0,05). Concluiu-se que a adição de nistatina, clorexidina e cetoconazol nas CIMs para o biofilme de C. albicans não resultou em efeitos deletérios na resistência à tração e na percentagem de alongamento dos materiais resilientes temporários para base de prótese até o período de 14 dias. A adição de antifúngicos nas CIMs não resultou em efeitos adversos à porosidade de ambos os materiais resilientes temporários em diferentes períodos de imersão em água, com exceção da clorexidina e nistatina no Softone e clorexidina no Trusoft aos 14 dias. Não foram observados efeitos deletérios para a porosidade de ambos os materiais resilientes modificados com as CIMs dos fármacos durante os 14 dias de imersão na S50. / This study investigated the tensile strength (ultimate tensile strength- UTS) and porosity of temporary soft denture liners modified by minimum inhibitory concentrations (MICs) of antifungal agents for Candida albicans biofilm (SC5314). For UTS tests, dumbbell-shaped specimens (n=7) with a central cross-sectional area of 33 mm x 6 mm x 3 mm were produced by resilient materials (Trusoft and Softone) without (control) or with incorporation of five drugs at MICs: nystatin- 0.032 g; chlorhexidine diacetate-0.064 g; ketoconazole- 0.128 g; miconazole- 0.256 g; itraconazole- 0.256 g (each per gram of soft liner powder). After plasticization, specimens were immersed in distilled water at 37°C for 24 h, 7 and 14 days, and then tested in tension in a universal testing machine (EMIC DL-500 MF) at 40 mm/min. The porosity was measured by water absorption, based on exclusion of the plasticizer effect. Initially, it was determined by sorption isotherms that the adequate storage solution for specimens (65 mm x 10 mm x 3.3 mm) of both materials was 50% anhydrous calcium chloride (S50). Then, the porosity factor (PF) was calculated for the study groups (n=10) formed by specimens without (control) or with drug incorporation at MICs (nystatin, chlorhexidine or ketoconazole) after storage in distilled water or S50 for 24 h, 7 and 14 days. Data of tensile strength (MPa) and elongation percentage (%) were submitted to 3-way ANOVA followed by Tukey\'s test (=0.05). Data of porosity were statistically analyzed by 4-way repeated measures ANOVA and Tukeys test (=0.05). At the end of 14 days, the tensile strength for both materials was significantly lower in the groups modified by miconazole and itraconazole compared to the other groups (P<0.0001), which showed no significant difference between them (P>0.05). After 7 and 14 days in water, miconazole and itraconazole added into both materials result in significant lower elongation percentages compared to the other drugs and control (P<.0001), which were similar to each other (P>0.05). Ketoconazole resulted in no significant changes in PF for both liners in water over 14 days (P>0.05). Compared to the controls, Softone and Trusoft PFs were increased at 14-day water immersion only after addition of nystatin and chlorhexidine, and chlorhexidine, respectively (P<0.05). Both materials showed no significant changes in PF in up to 14 days of S50 immersion, compared to the controls (P>0.05). In all experimental conditions, Softone and Trusoft PFs were significantly lower when immersed in S50 compared to distilled water (P<0.05). It was concluded that the addition of the nystatin, chlorhexidine and ketoconazole at MICs for C. albicans biofilm resulted in no harmful effects on the ultimate tensile strength and elongation percentage of the temporary soft denture liners up to 14-day period. The addition of antifungals at MICs resulted in no detrimental effects for the porosity of both temporary soft liners in different periods of water immersion, except for chlorhexidine and nystatin in Softone and chlorhexidine in Trusoft at 14 days. No deleterious effect was observed for the porosity of both soft liners modified by the drugs at MICs over 14 days of S50 immersion.
126

Atividade antifúngica, mecanismo de ação, citotoxidade e ação antibiofilme da cloramina T sobre Candida spp.

Ferreira, Gabriela Lacet Silva 17 August 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-03-06T13:18:25Z No. of bitstreams: 1 arquivo total.pdf: 1622677 bytes, checksum: 4910b306e46e741a75cc3d2047affa2c (MD5) / Made available in DSpace on 2017-03-06T13:18:25Z (GMT). No. of bitstreams: 1 arquivo total.pdf: 1622677 bytes, checksum: 4910b306e46e741a75cc3d2047affa2c (MD5) Previous issue date: 2015-08-17 / Introduction: Faced with limitations to the use of sodium hypochlorite in the disinfection of dental prostheses and the need to control fungal proliferation in these sites, it is necessary to study new substances for this purpose. Objectives: To evaluate the antifungal activity, mechanism of action, cytotoxicity and antibiofilm action of chloramine T (CAT) on Candida spp. The minimum inhibitory concentration (MIC) of the substance on Candida albicans, Candida tropicalis, Candida krusei and Candida glabrata was determined by the microdilution technique and the minimum fungicidal concentration (CFM) was calculated through the subculture in Sabouraud Dextrose Agar (ASD) . The growth inhibition kinetics of C. albicans were evaluated by the method of counting colony forming units (CFU) at different times and concentrations. A microculture of C. albicans was performed on fowl agar plus tween 80 to evaluate the possible alteration of micromorphology against different concentrations of the substance. The possible mechanism of action on wall and fungal cell membrane was verified by the determination of MIC in the presence of sorbitol and ergosterol respectively. The inhibition of the initial adherence of fungal cells, formation and reduction of C. albicans biofilm were evaluated after short (1 min) and prolonged (8 h) contact with the substance and formation of the biofilm was measured by absorbance at 600 nm, Transformed into scores referring to the percentage of inhibition obtained based on the values ​​of the control group. The cytotoxicity of the substance was evaluated by the hemolysis method. Nystatin and sodium hypochlorite were used as positive controls. A descriptive and inferential analysis was performed considering α = 5%. Results: The CIM75% found for CAT was 781.3 μg / mL and the CFM / MIC ratio suggests a fungicidal activity against most of the strains tested, with probable action on cell wall and membrane. The substance showed immediate and prolonged action on the kinetic test and caused reduction of the filamentous form and inhibition of chlamydoconidia. In the biofilm assay, it presented similar results to sodium hypochlorite for inhibition of initial adherence and formation of mature biofilm (p> 0.05) and was more effective in reducing mature biofilm in the short contact groups at MIC concentration x2 (24 H) and CIM x 4 (48 h) (p <0.05). Conclusion: CAT shows antifungal activity on Candida spp. And shows fungicidal action on most of the strains tested. Its action is immediate and prolonged in the inhibition of C. albicans growth and probably occurs both in the wall and in the cell membrane. CAT causes alterations in the micromorphology of C. albicans and has antibiofilm activity, being effective in inhibiting the initial adherence of fungal cells, as well as in the formation and reduction of biofilm. / Introducao: Diante das limitacoes para o uso do hipoclorito de sodio na desinfeccao de proteses dentarias e da necessidade do controle da proliferacao fungica nestes sitios, faz-se necessario o estudo de novas substancias para este fim. Objetivos: Avaliar a atividade antifungica, mecanismo de acao, citotoxicidade e acao antibiofilme da cloramina T (CAT) sobre Candida spp. Materiais e Metodos: Foi determinada a concentracao inibitoria minima (CIM) da substancia sobre Candida albicans, Candida tropicalis, Candida krusei e Candida glabrata pela tecnica da microdiluicao e calculada a concentracao fungicida minima (CFM) atraves do subcultivo em Agar Sabouraud Dextrose (ASD). Foi avaliada a cinetica de inibicao do crescimento de C. albicans pelo metodo de contagem de unidades formadoras de colonias (UFC) em diferentes tempos e concentracoes. Foi realizado microcultivo de C. albicans em agar fuba acrescido de tween 80 para avaliacao da possivel alteracao da micromorfologia frente a diferentes concentracoes da substancia. O possivel mecanismo de acao sobre parede e membrana celular fungica foi verificado atraves da determinacao da CIM na presenca, respectivamente, de sorbitol e ergosterol. A inibicao da aderencia inicial de celulas fungicas, formacao e reducao do biofilme de C. albicans foram avaliados apos contato curto (1 min) e prolongado (8 h) com a substancia e a formacao do biofilme foi mensurada atraves de absorbancia a 600 nm, transformada em escores referentes a porcentagem de inibicao obtida com base nos valores do grupo controle. A citotoxicidade da substancia foi avaliada pelo metodo da hemolise. Nistatina e hipoclorito de sodio foram utilizados como controles positivos. Foi realizada analise estatistica descritiva e inferencial, considerando α=5%. Resultados: A CIM75% encontrada para a CAT foi de 781,3 µg/mL e a relacao CFM/CIM sugere uma atividade fungicida frente a maioria das cepas testadas, com provavel acao em parede e membrana celulares. A substancia mostrou acao imediata e prolongada no teste de cinetica e provocou reducao da forma filamentosa e inibicao de clamidoconidios. No ensaio do biofilme, apresentou resultados semelhantes ao hipoclorito de sodio para inibicao da aderencia inicial e formacao do biofilme maduro (p>0,05) e foi mais efetiva na reducao do biofilme maduro nos grupos de contato curto na concentracao CIM x 2 (24 h) e CIM x 4 (48 h) (p < 0,05). Conclusao: A CAT apresenta atividade antifungica sobre Candida spp. e apresenta acao fungicida sobre a maioria das cepas testadas. Sua acao e imediata e prolongada na inibicao do crescimento de C. albicans e provavelmente ocorre tanto em parede quanto em membrana celular. A CAT causa alteracoes na micromorfologia de C. albicans e possui atividade antibiofilme, sendo efetiva na inibicao da aderencia inicial das celulas fungicas, bem como na formacao e reducao do biofilme.
127

Efeito de tempos de simulação do intemperismo natural na deformação permanente dos materiais reembassadores resilientes e na resitencia a tração da sua união com a resina acrilica / Effect of accelerated ageing on the permanet deformation and tensite bond strenght of auto-polymerizing soft dentures liners

Takahashi, Jessica Mie Ferreira Koyama 02 May 2009 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T19:45:53Z (GMT). No. of bitstreams: 1 Takahashi_JessicaMieFerreiraKoyama_M.pdf: 3156848 bytes, checksum: e45be536e6455880f4523ac84c0d2894 (MD5) Previous issue date: 2009 / Resumo: O objetivo neste estudo foi avaliar o efeito de diferentes tempos de envelhecimento acelerado realizado por meio da simulação do intemperismo natural, sobre as propriedades de deformação permanente e resistência à tração da união de dois materiais resilientes usados como forradores de base de prótese, sendo um à base de resina acrílica e outro à base de silicone. Para o ensaio de resistência à tração da união, os materiais reembasadores foram unidos a dois blocos de resina acrílica (9 X 9 X 40 mm) utilizada para a confecção de bases de próteses totais. Para o ensaio de deformação permanente, os corpos-de-prova de reembasador resiliente apresentaram 19 mm de altura e 12,7 mm de diâmetro. Os corpos-de-prova (n=10) foram submetidos ao envelhecimento acelerado nos tempos 2, 4, 8, 16, 32 e 64 ciclos por meio da simulação do intemperismo natural. O ensaio de resistência à tração da união foi realizado em máquina de ensaios EMIC DL-500 MF com velocidade média de 5 mm/min, sendo avaliado também o tipo de falha de união (adesiva, coesiva ou mista). Para o ensaio de deformação permanente foi utilizado aparelho mecânico descrito na especificação no 18 da A.D.A., com carga compressiva de 750 gf. Foi realizada análise estatística utilizando o teste Kruskall-Wallis associado ao método de Dunn, para comparação entre os materiais no mesmo intervalo de envelhecimento, e o teste Mann-Whitney para comparação do efeito dos tempos de envelhecimento em cada material. Avaliando os resultados obtidos após a análise estatística, pôde-se observar que o reembasador à base de silicone apresentou menor porcentagem de deformação permanente (p<0,0001) e maior resistência à tração (p<0,0001) que o reembasador à base de resina acrílica em todos os intervalos de envelhecimento. E que a simulação do intemperismo natural não afetou a deformação permanente (p=0,90) e a resistência à tração (p=0,15) do reembasador à base de silicone, mas reduziu a porcentagem de deformação permanente e aumentou a resistência à tração do material à base de resina acrílica (p<0,05). Os resultados demonstraram que o reembasador resiliente à base de silicone é menos susceptível à cargas compressivas, pois apresentou melhor recuperação elástica, menor deformação permanente e maior resistência à tração que o à base de resina acrílica. E que o envelhecimento acelerado, afeta as propriedades de deformação permanente e resistência à tração do material reembasador à base de resina acrílica. / Abstract: This study aimed to evaluate the effect of different times of accelerated ageing over the properties of permanent deformation and tensile bond strength of two soft liners used on prostheses relining. The soft liners studied were auto-polymerizing and acrylic resin and silicone based. The materials were processed according the manufacturers' instructions. The resilient liner specimens (9 X 9 X 3 mm) for tensile bond strength were processed between 2 acrylic resin blocks (9 X 9 X 40 mm). The resilient liner specimens for permanent deformation test were 19 mm height and 12.7 mm diameter. The specimens (n=10) were submitted to accelerated ageing process during 2, 4, 8, 16, 32 and 64 cycles. Tensile bond strength was performed with crosshead speed of 5 mm/min using a testing machine EMIC DL-500 MF. Permanent deformation was performed with an apparatus described on specification no 18 of A.D.A., with compressive load of 750 gf. Statistical analysis was performed using Kruskall-Wallis and Dunn tests to compare materials on the same ageing period and Mann-Whitney test to compare the effect of different ageing periods on each material. The results obtained after statistical analysis demonstrated that the silicone based reliner presented lower percentage of permanent deformation (p<0.0001) and higher tensile bond strength (p<0.0001) than the acrylic resin based reliner in all the ageing intervals. And that the accelerated ageing process did not affect the permanent deformation (p=0.90) and tensile bond strength (p=0.15) of the silicone based reliner, but reduced the percentage of permanent deformation and increased tensile bond strength of the acrylic resin based reliner (p<0.05). Results demonstrated that silicone based reliner is less susceptible to compressive loads, presenting better elastic recovery, lower permanent deformation and higher tensile bond strength. And that accelerated ageing affected only acrylic resin based reliners. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
128

Efeito do etil-cianoacrilato (Super Bonder®) e do polidor líquido de baixa viscosidade (Biscover®) sobre biofilme de Candida albicans em resina acrílica para reembasamento / Effect of ethyl-cyanoacrylate (Super Bonder®) and a liquid polish of low viscosity (Biscover®) on Candida albicans biofilms on denture reline resin

Flora Freitas Fernandes Távora 10 July 2012 (has links)
A proposta desse trabalho foi verificar através de microscopia confocal de varredura a laser, se a utilização de uma resina fotopolimerizável de baixa viscosidade (Biscover®) e do etil-cianoacrilato (Super Bonder®) seriam eficientes em prevenir ou reduzir a formação de biofilme de Candida albicans. Cinqüenta e seis corpos de prova em resina acrílica para reembasamento (New Truliner) foram divididos aleatoriamente em 7 grupos: G1 (C)- Controle; G2 (SBAE)- Recebeu uma camada de Super Bonder® em sua superfície antes de esterilizar; G3 (SBDE)- Recebeu uma camada de Super Bonder® em sua superfície depois de esterilizar; G4 (SB3G)- 3 gotas de Super Bonder® incorporadas na resina; G5 (SB4G)- 4 gotas de Super Bonder® incorporadas na resina; G6 (BCDE)- Recebeu uma camada de Biscover® em sua superfície depois de esterilizar e G7 (BCAE) Recebeu uma camada de Biscover® em sua superfície antes de esterilizar. Todos os corpos de prova foram inoculados com Candida albicans para formação de biofilme. Os biofilmes remanescentes sobre os corpos de prova foram corados através dos fluorocromos SYTO-9 e iodeto de propídeo para análise no microscópio confocal. Os dados foram analisados através dos testes estatísticos de Kruskal-Wallis e Dunn, a um nível de significância de 5%. Os resultados obtidos pelo microscópio confocal mostraram que, de todos os corpos de prova modificados, os que receberam a Super Bonder® em sua superfície, G2(SBAE) e G3(SBDE) foram os únicos que significativamente reduziram a formação de biofilme de Candida albicans. Através da análise das imagens geradas pelo microscópio confocal, pôde-se observar que nos grupos G2(SBAE) e G3(SBDE) os campos apresentaram um reduzido número de células fúngicas e a maioria se encontrava na forma de levedura (inócua), enquanto que, para os demais grupos, além de observado um elevado número de células, a maioria destas se apresentava em forma de hifa (patogênica). Desse modo, a partir das condições experimentais desse estudo pôde-se concluir que as modificações do material testado com a Super Bonder® aplicada em sua superfície podem ser uma abordagem potencialmente útil para reduzir ou controlar a formação do biofilme em resinas acrílicas. / The purpose of this study was to verify, using the confocal laser scanning microscopy (CLSM), if the use of a photoactivated resin of low viscosity (Biscover®) and a ethyl-cyanoacrylate (Super Bonder®) could be efficient in the prevention or reduction of Candida albicans biofilms. Fifty six reline resin specimens (New Truliner) were fabricated and randomly divided into 7 groups: G1 (C)- Control; G2 (SBAE)- a Super Bonder® layer was applied on the surface before sterilization; G3 (SBDE)- the surface received a Super Bonder® layer after sterilization; G4 (SB3G)- 3 drops of Super Bonder® were incorporated in the structure of the resin; G5 (SB4G)- 4 drops of Super Bonder® were incorporated in the structure of the resin; G6 (BCDE)- a Biscover® layer was applied on the surface after sterilization; G7 (BCAE) the surface received a Biscover® layer before sterilization. All the specimens were inoculated with Candida albicans for biofilm dvelopment. The remaining biofilms on the specimens were stained with fluorochromes SYTO-9 and propidium iodide to be analyzed by CLSM. The data were statistically analyzed using the Kruskal-Wallis and Dunn test, considering a significance level of 5%. The data obtained by CLSM revealed that of all specimens modified, those that received a Super Bonder® layer on their surface, G2(SBAE) e G3(SBDE), presented the better results, reducing Candida albicans biofilm formation. Analyzing the images produced by CLSM it was possible to see that groups G2(SBAE) e G3(SBDE) showed a reduced number of cells, and they were in a less phatogenetic form (Yeast), while the other groups showed a high number of cells in a more pathogenetic form (Hyphae). Considering the experimental conditions of this study we can conclude that the material modifications done with Super Bonder® on the surface could be an interesting way to prevent or control biofilm formation on acrylic resin.
129

Efeito de soluções higienizadoras na retenção de cápsulas do tipo o\'ring / Effect of denture cleansers on the retention of capsules type o-ring

Thereza Cristina Lira Pacheco 04 September 2015 (has links)
Soluções higienizadoras podem acarretar efeitos prejudiciais para as próteses, como deterioração da base da prótese e pigmentação. Porém, pouco se conhece sobre os efeitos destas na vida útil dos sistemas de retenção de uma overdenture. Deste modo, este estudo buscou avaliar se imersões diárias em clorexidina 2%, hipoclorito de sódio 1%, Corega® Tabs e água (controle) poderia acelerar a perda de retenção em attachments do tipo o´ring (S.I.N sistema de implantes®). Foram confeccionados 40 corpos de prova contendo cápsulas com anéis de borracha, simulando uma overdenture, e apenas 01 contendo o implante com o pilar o´ring. Eles foram separados em quatro grupos (n=10) e simulados noventa dias de imersões. Após, foram realizados testes de resistência à tração em uma máquina de ensaios mecânicos (MTS 810), antes e após a ciclagem com 270 ciclos, equivalentes a remoção e inserção da prótese três vezes ao dia, durante um período de três meses. Os resultados foram avaliados estatisticamente através dos testes ANOVA a dois critérios e do teste de Tukey (p&#x2264;0.05). Os valores médios (Newton) encontrados antes e após a imersão foram, respectivamente: Água - 9,482 / 6,081; Clorexidina - 9,972 / 7,390; Hipoclorito: 6,954 / 6,265 e Corega® Tabs: 12,464 / 11,121. Entre os grupos Clorexidina, Hipoclorito de sódio e Água não houve diferenças significativas. Houve diferenças estatisticamente significativas entre o grupo Corega® Tabs e os grupos controle e Hipoclorito de sódio, mas não com a Clorexidina. Assim, pôde-se concluir que soluções higienizadoras tiveram efeitos significativos na capacidade de retenção dos o´rings após o período simulado de três meses de imersão. / Denture cleansers can cause adverse effects on the prostheses, as deterioration of the denture base and pigmentation. However, little is known about its impacts on the life of an overdenture retention systems. Thus, this study sought to evaluate whether daily immersion in chlorhexidine 2%, sodium hypochlorite 1%, Corega® Tabs and water (control) would increase the retention loss in the O-ring type attachments (SIN implantes® system). Forty specimens containing capsules were made with rubber rings, simulating an overdenture, and only one containing the implant with the O-ring abutment. They were divided into four groups (n = 10) and ninety days in immersion were simulated, thereafter, conducted tensile strength tests on a testing machine (MTS - 810) before and after cycling of 270 cycles, equivalent to removal and insertion of the prosthesis three times a day for a period of three months. The results were statistically evaluated by the ANOVA two criteria and the Tukey test (p&#x2264;0.05). The mean values (Newton) found before and after immersion were: Water - 9,482 / 6,081; Chlorhexidine - 9,972 / 7,390; Hypochlorite: 6,954 / 6,265 and Corega® Tabs: 12.464 / 11.121. Among the groups chlorhexidine, sodium hypochlorite and water there were no significant differences. There were statistically significant differences between the group Corega® Tabs and controls and sodium hypochlorite groups, but not with the chlorhexidine. Thus, it concluded that denture cleansers had significant effects on retention capacity of orings after the simulated period of three months of immersion.
130

Eficácia da ação antimicrobiana de soluções químicas - hipoclorito alcalino e mamona (Ricinus communis) - frente a micro-organismos específicos / Efficacy of antimicrobial action of chemical solutions - alkaline hypochlorite and castor oil (Ricinus communis) - against specific microorganisms

Marcela Moreira Salles 27 June 2013 (has links)
O objetivo deste trabalho foi avaliar, por meio de estudo laboratorial e clínico, a eficácia de soluções de hipoclorito alcalino (0,25% e 0,5%) e à base de mamona (Ricinus communis) a 10% quanto à ação antimicrobiana frente a micro-organismos específicos, por meio da contagem de Unidades Formadoras de Colônias (UFC). No estudo laboratorial, a partir de matrizes metálicas quadrangulares (10 x 2 mm), foram confeccionados 360 corpos de prova de resina acrílica termopolimerizável (Lucitone 550), os quais foram esterilizados em micro-ondas (650W, por 6 minutos), contaminados com cepas de Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans, Bacillus subtilis, Escherichia coli, Streptococcus mutans, Enterococcus faecalis e Candida glabrata e imersos (20 minutos) em soluções higienizadoras (n=10): Grupo A - Hipoclorito de sódio 0,25%; Grupo B - Hipoclorito de sódio 0,5%; Grupo C - Solução de mamona a 10%; Grupo D (Controle positivo) - solução salina e Grupo E (Controle negativo) - sem contaminação e imerso em solução salina (n=5). Em seguida, foram lavados em solução salina e imersos em meio de cultura líquido (Letheen), a partir do qual foram obtidas diluições seriadas (100 e 10-3), as quais foram semeadas em meios de cultura seletivos. Após incubação a 37ºC por 24 horas, as colônias foram contadas e os valores de UFC/mL calculados. No estudo clínico, 64 pacientes, usuários de próteses totais, foram orientados a escovar suas próteses (escova Bitufo® e sabonete líquido neutro) três vezes ao dia e imergí-las (20 minutos), uma vez ao dia, em soluções: Solução 1 - Hipoclorito de sódio 0,25%; Solução 2 - Hipoclorito de sódio 0,5%; Solução 3 - Solução de mamona a 10% e Solução 4 - solução salina (controle). De acordo com uma sequência aleatorizada, cada solução foi utilizada por 7 dias, com um período de wash out entre elas. A avaliação da ação antimicrobiana foi realizada antes dos uso dos produtos (Baseline) e após os 7 dias de uso de cada uma das soluções, por meio da contagem de Unidades Formadoras de Colônias (UFC) de Streptococcus mutans, Candida spp. e gram negativos. Para coleta do biofilme, cada prótese total superior foi colocada em placa de Petri e a superfície interna escovada (escova Tek e solução salina) por 2 minutos, sendo a suspensão transferida para tubo de ensaio. Após diluições decimais (100 até 10-3), alíquotas de 50 &mu;L foram semeadas em placas de Petri contendo Mitis Salivarius Agar Base, Chromagar® Candida e Mac Conkey Agar para a detecção de Streptococcus mutans, Candida spp. ou gram negativo, respectivamente. Após incubação a 37ºC (em microaerofilia durante 48-72 horas para grupo mutans e aerobiose durante 48 horas para Candida spp. e gram negativo), de acordo com morfologia típica, o número de colônias características foi mensurado e o número de UFC/mL calculado. Os dados obtidos foram transformados de acordo com a fórmula log10 (UFC+1) e analisados estatisticamente por meio do teste t de Student (&alpha;=0,05), para a análise laboratorial, e teste de Friedman (&alpha;=0,05), para a análise clínica. Os resultados mostraram que, no estudo laboratorial, as soluções de hipoclorito de sódio (0,25% e 0,5%) eliminaram completamente todos os micro-organismos. A solução de mamona eliminou completamente B. subtilis, não apresentou efeito sobre E. faecalis e apresentou ação antimicrobiana moderada frente às demais cepas, havendo redução significante (p < 0,05) do número de UFC quando comparado com o grupo D (controle positivo). No estudo clínico, houve diferença significante entre as soluções (P < 0,001), sendo que o hipoclorito de sódio a 0,5% apresentou ação efetiva sobre todos os micro-organismos avaliados (Candida spp., S. mutans e gram negativos); o hipoclorito de sódio 0,25%, ação efetiva sobre S. mutans e moderada sobre Candida spp. e gram negativos, e a solução de mamona, ação efetiva sobre S. mutans e moderada contra Candida spp. A espécie de Candida mais frequentemente isolada foi C. albicans, seguida pelas espécies C. tropicalis e C. glabrata. Concluiu-se que a solução de hipoclorito de sódio 0,5% foi a mais efetiva, apresentando ação antimicrobiana sobre ambos os biofilmes (in vitro e in vivo), seguida pela solução de hipoclorito de sódio 0,25% que apresentou ação antimicrobiana sobre o biofilme in vitro e sobre S. mutans (biofilme in vivo). A solução de mamona (10%) foi a menos efetiva, apresentando ação antimicrobiana sobre B. subtilis (biofilme in vitro) e S. mutans (biofilme in vivo). / The objective of this study was to evaluate, through laboratory and clinical study, the efficacy of alkaline hypochlorite solutions (0.25% and 0.5%) and 10% castor oil solution (Ricinus communis) about the antimicrobial action against specific microorganisms, by counting the number of Colony Forming Units (CFU). In the laboratory study, 360 denture base acrylic resin specimens (Lucitone 550) were obtained from square metal matrix (10 mm x 2 mm), which were sterilized with microwave (650W, for 6 minutes), contaminated with Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans, Bacillus subtilis, Escherichia coli, Streptococcus mutans, Enterococcus faecalis and Candida glabrata and immersed (20 minutes) in the hygiene solutions (n = 10): Group A - 0.25% Sodium Hypochlorite; Group - B - 0.5% Sodium hypochlorite; Group C - 10% Castor oil solution; Group D (Positive Control) - saline and Group E (Negative Control) - no contamination and immersed in saline (n = 5). The specimens were washed in saline solution and immersed in liquid culture medium (Letheen), from which were obtained serial dilutions (100 to 10-3) and seeded into selective solid media. After incubation at 37º C for 24 hours, the colonies were counted and the values of CFU/mL calculated. In the clinical study, 64 complete denture wearers were instructed to brush their dentures (Bitufo ® brush and liquid neutral soap) three times a day and to soak them (20 minutes), once a day, in the solutions: Solution 1 - 0.25% Sodium Hypochlorite; Solution 2 - 0.5% Sodium hypochlorite; Solution 3 - 10% Castor oil and Solution 4 - saline (control). According to a randomized sequence, each solution was used for 7 days, with a period of wash out between them. The evaluation of the antimicrobial action was performed before the use of the products (Baseline) and after 7 days after using each solution, by counting the Colony Forming Units (CFU) of Streptococcus mutans, Candida spp. and gram negative. For collection of the biofilm, each upper complete denture was placed in a Petri dish, the internal surface was brushed with saline solution for 2 minutes and the suspension was transferred to a test tube. After decimal dilutions (100 to 10-3), aliquots of 50 uL were seeded inside Petri dishes containing Mitis Salivarius Agar Base, Candida Chromagar ® and Mac Conkey Agar for the detection of Streptococcus mutans, Candida spp. or gram negative, respectively. After incubation at 37° C (in microaerophilic conditions for 48-72 hours for mutans and aerobiosis for 48 hours for Candida spp. and gram negative), in accordance with characteristic morphology, the number of characteristic colonies was countedand the number of CFU/ml calculated. Data were processed following transformation into the formula log10 (CFU +1) and statistically analyzed using the Student t test (&alpha; = 0.05) for laboratory analysis, and Friedman test (&alpha; = 0.05), for clinical analysis. The results showed that, in the laboratory study, sodium hypochlorite (0.25% and 0.5%) eliminated completely all microorganisms. The Castor oil solution eliminated B. subtilis, had no effect on E. faecalis and showed moderate antimicrobial activity against other strains, with a significant reduction (p <0.05) in the number of CFU compared with group D (positive control). In the clinical study, there was significant difference between the solutions (P <0.001), and 0.5% sodium hypochlorite had effective action on all evaluated microorganisms (Candida spp., S. mutans and gram negative); 0.25% sodium hypochlorite had effective action on S. mutans and moderate on Candida spp. and gram negative, and the castor oil solution had effective action on S. mutans and moderate against Candida spp. . The Candida species most often isolated was C. albicans, followed by the species C. tropicalis and C. glabrata. It was concluded that the solution of 0.5% sodium hypochlorite was the most effective presenting antimicrobial action on both biofilms (in vitro and in vivo), followed by 0.25% sodium hypochlorite solution that showed antimicrobial activity on biofilms in vitro and on S. mutans (biofilm in vivo). The 10% castor oil was less effective, with antimicrobial action on Bacillus subtilis (biofilm in vitro) and S. mutans (biofilm in vivo).

Page generated in 0.2001 seconds