Spelling suggestions: "subject:"Dental prosthesis"" "subject:"Dental prosthesisb""
231 |
Comportamento biomecânico de estruturas multicamadas em restaurações protéticas / Biomechanical behavior of multilayer structures in dental prostheticCosta, Anna Karina Figueiredo [UNESP] 28 January 2016 (has links)
Submitted by ANNA KARINA FIGUEIREDO COSTA null (karina_fcosta@yahoo.com.br) on 2016-04-21T11:28:44Z
No. of bitstreams: 1
Anna Karina final 20 abril 2016.pdf: 2862170 bytes, checksum: d49986540a33df5c364771ff7f6659c6 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-05-02T16:35:35Z (GMT) No. of bitstreams: 1
costa_akf_dr_sjc.pdf: 2862170 bytes, checksum: d49986540a33df5c364771ff7f6659c6 (MD5) / Made available in DSpace on 2016-05-02T16:35:35Z (GMT). No. of bitstreams: 1
costa_akf_dr_sjc.pdf: 2862170 bytes, checksum: d49986540a33df5c364771ff7f6659c6 (MD5)
Previous issue date: 2016-01-28 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo desse trabalho foi identificar por meio da utilização de geometrias complexas (pela análise de elemento finito) e simplificadas, se novas tecnologias (sistema CAD/CAM) resultam em um comportamento biomecânico mais favorável na cerâmica de cobertura quando comparado à técnica de aplicação convencional (estratificação). Foram modelados três diferentes estruturas de prótese parcial fixa de três elementos com diferentes técnicas de fabricação: convencional, Rapid Layer (feldspática, cimento resinoso e zircônia) e CAD-on (dissilicato, material vítrio de baixa fusão e zircônia) a fim de analisar a distribuição tensão de tração gerada durante um ensaio mecânico pelo método por elementos finitos. Discos (cerâmica de cobertura e zircônia) foram unidos seguindo as três diferentes técnicas (convencional, Rapid Layer e CAD-on). Foram também confeccionadas próteses parciais fixas de 3 elementos pela técnica de multicamada seguindo as mesmas configurações dos modelos utilizados na análise por elementos finitos. Essas coroas foram cicladas durante 2x106 ciclos para analisar falhas na cerâmica de cobertura, como trincas, lascamento, delaminação e falha catastrófica. Os resultados mostraram que as coroas confeccionadas com cerâmica de dissilicato de lítio e material vítreo na interface infraestrutura/cerâmica de cobertura apresentaram menor concentração de tensão de tração quando comparadas aos modelos confeccionados pela técnica convencional, que demonstraram maior concentração de tensão de tração entre as camadas (cerâmica de cobertura, interface e infraestrutura). Para os discos, o acréscimo de material na interface cerâmica de cobertura e infraestrutura mostrou maior resistência à fratura biaxial e menor propagação da trinca entre as camadas de cerâmica. As coroas cicladas não apresentaram falhas como: trincas, lascamento, delaminação e catastrófica nos primeiros 500.000 ciclos. Porém, as próteses confeccionadas com cerâmica feldspática apresentaram trincas a partir de 1x106 ciclos, diferentemente das coroas confeccionadas na técnica Rapid Layer e CAD-on. As coroas confeccionadas pela técnica RL e CAD-on podem ser consideradas um sistema favorável por prevenir a propagação de trincas radiais em direção à superfície da restauração e melhorar a tenacidade à fratura do material. / The aim was to identify whether the CAD/CAM approach resulted in more favourable stressing patterns in the veneer-ceramic when compared with a conventionally sintered Y-TZP core/veneer-ceramic. Three different designs crowns of prosthesis with three elements and different manufacturing techniques were modeled: conventional technique, Rapid Layer (feldspathic ceramic, resin cement and zirconia) and CAD-on (disilicate, fusion glass ceramic and zirconia) techniques to analyze the distribution stress tensile generated during a mechanical test by the finite element method. Moreover, were made feldspathic ceramic discs, lithium disilicate discs and Y-TZP zirconia discs to analyze the influence of biaxial flexure stress of these three different techniques. These discs (veneer ceramic and zirconia ceramic) were joined following the three different techniques (conventional, Rapid Layer and CAD-on). They were also made FPDs 3 elements: following the same design of models used in finite element analysis. These crowns were cycled during 2x106 cycles to analyze failure at veneer ceramic, such as cracks, chipping, delamination and catastrophic failure. The results showed that the crowns made from ceramic lithium disilicate and low fusion glass ceramic at the interface veneer ceramic/infraestructure showed low concentration of tensile stress when compared to models made by the conventional technique, which showed a greater concentration of tensile stress between layers (veneer ceramic, interface and infrastructure). For the discs samples, the multilayer materials showed lower crack propagation between the ceramic layers. The cycled crowns showed no failure as cracks, chipping, delamination and catastrophic failure for the first 500,000 cycles. However, the prostheses made with feldspathic ceramic showed cracks from 1.106 cycles. The incorporation of functionally and aesthetically graded layers would be realisable, considerable research would be required before the feasibility of the conceptual approach could be accurately assessed. / FAPESP: 2012/11095-0
|
232 |
Estudo do desajuste angular e vertical em próteses fixas implantossuportadas por meio do MEF-3DGomes, Érica Alves [UNESP] 17 September 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-09-17Bitstream added on 2014-06-13T19:44:52Z : No. of bitstreams: 1
gomes_ea_dr_araca.pdf: 12533208 bytes, checksum: 62db616b630b0f9a9807e6b24297d9e8 (MD5) / Objetivo: A análise pelo método dos elementos finitos tridimensional foi utilizada para avaliar o efeito dos desajustes angular e vertical simulado em próteses fixas implantossuportadas parafusadas de 3 elementos, na resposta biomecânica do tecido ósseo peri-implantar, implantes e componentes protéticos. Material e método: Foram confeccionados 4 modelos tridimensionais, representativos de secção mandibular direita contendo um implante na região de segundo pré-molar (2oPM) e outro na região de segundo molar (2oM) ferulizados por uma prótese metalocerâmica implantossuportada parafusada de 3 elementos, diferenciados pelo tipo de desajuste protético, gerando os grupos: GC (grupo controle) - prótese totalmente adaptada aos implantes, DAU (desajuste angular unilateral) - prótese com desajuste angular unilateral de 100μm na região mesial do 2oM, DVU (desajuste vertical unilateral) - prótese com desajuste vertical unilateral de 100μm na região mesial do 2oM e DVT (desajuste vertical total) - prótese com desajuste vertical de 100μm em toda a plataforma de assentamento da infraestrutura no 2oM. Com a utilização do programa de elementos finitos Ansys® uma força vertical total de 400N foi distribuída em 12 pontos de parada cêntrica, sendo que cada molar recebeu um carregamento total de 150N e o 2oPM de 100N, gerando mapas de tensões. Resultados: Verificou-se que a distribuição e os valores de tensões para o tecido ósseo peri-implantar foram similares para todos os grupos. Os grupos com desajustes alteraram o padrão de distribuição e elevaram a magnitude das tensões em relação ao grupo GC. No grupo DAU os maiores valores de tensões foram observados no corpo do implante e parafuso de retenção. Já nos grupos DVU e DVT elevados valores de tensões foram encontrados na plataforma de assentamento da infraestrutura... / Purpose: The three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in 3-piece implant-supported and screw-retained fixed prostheses on biomechanical response in peri-implant bone tissue, implants and prosthetic components. Material and method: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of second premolar (2°PM) and other in the region of second molar (2°M). The implants were splinted by a 3- piece implant-supported metal ceramic prosthesis and differed according to the type of misfit as represented by the groups: CG (control group) - prosthesis with complete fit to the implants, UAM (unilateral angular misfit) – prosthesis presenting unilateral angular misfit of 100μm in the mesial region of the 2°M, UVM (unilateral vertical misfit) – prosthesis presenting unilateral vertical misfit of 100μm in the mesial region of the 2°M, and TVM (total vertical misfit) – prosthesis presenting total vertical misfit of 100μm in the platform of the framework in the 2°M. A vertical load of 400N was distributed and applied on 12 centric points by the software Ansys®. So, vertical loading of 150N was applied on each molar while vertical load of 100N was applied on the 2°PM. Stress maps were obtained by processing of the finite element software. Results: The stress values and distribution on peri-implant bone tissue were similar for all groups. The groups presenting misfit exhibited different distribution pattern and increased stress magnitude in comparison to the group CG. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework... (Complete abstract click electronic access below)
|
233 |
Distribuição de tensões geradas por próteses esplintadas ou individualizadas sobre implantes com reabilitações em diferentes rebordos. Análise pelo método dos elementos finitos / Stress distribution generated by splinted or individualized implant prostheses with rehabilitation in different edges. A finite element analysisMarcelo Bighetti Toniollo 28 August 2014 (has links)
O emprego dos implantes ósseointegráveis na odontologia moderna tem conquistado destaque nas reabilitações de forma crescente. Em casos de perda óssea vertical severa, a qual se faz bastante presente em áreas posteriores mandibulares, o uso de implantes curtos e de diâmetro reduzido se faz necessário. Para que a reabilitação mantenha o plano oclusal nivelado, utiliza-se próteses sobre implantes com proporção coroa/implante aumentada, sendo importante avaliar se há sobrecarga das estruturas de suporte, e se convém a esplintagem da infraestrutura reabilitadora. Um dos métodos utilizados atualmente para análise de distribuição de tensões na odontologia é o método dos elementos finitos. Assim, este estudo teve o objetivo geral de comparar o desempenho biomecânico de próteses, esplintadas (PSIE) ou individualizadas (PSII), sobre implantes cone Morse de comprimento regular e curto, em área posterior de mandíbula. Foram usados modelos geométricos tridimensionais de implantes regulares ∅ 4x11 mm e curtos - ∅ 4x5 mm alojados em rebordos representativos do hemi-arco mandibular esquerdo posterior envolvendo o dente 34 adjacente ao espaço anodôntico, desenhados no programa SolidWorks 2007. Os 8 grupos experimentais foram: grupo controle E (3 implantes regulares reabilitados com PSIE), grupo 1E (2 implantes regulares e 1 curto reabilitados com PSIE), grupo 2E (1 implante regular e 2 curtos reabilitados com PSIE) e grupo 3E (3 implantes curtos reabilitados com PSIE); grupo controle I (3 implantes regulares reabilitados com PSII), grupo 1I (2 implantes regulares e 1 curto reabilitados com PSII), grupo 2I (1 implante regular e 2 curtos reabilitados com PSII) e grupo 3I (3 implantes curtos reabilitados com PSII); As alturas dos pilares usados foram 3,5 mm para implantes regulares e 0,8 mm para implantes curtos. Foram simuladas forças oblíquas (45° - linguo-vestibular) de 365N em molares e 200N em prémolares. Análises qualitativas e quantitativas da distribuição de tensões máximas e mínimas principais (ossos cortical e esponjoso) e tensão equivalente de von Mises (implantes, componentes e infraestruturas) foram feitas por meio do programa AnsysWorkbench10.0. Os resultados obtidos permitiram concluir que o uso de PSIE propiciou uma série de vantagens e benefícios com relação à distribuição de tensões nos elementos envolvidos no sistema, sendo benéfica a todos os grupos experimentais do presente estudo, notoriamente ao grupo com presença apenas de implantes curtos, diminuindo as tensões no osso circunjacente aos implantes, principalmente em sua abrangência. Também diminuiu as tensões na superfície dos implantes, na área de transmucoso dos pilares/componentes, na região interna das infraestruturas e sua abrangência ao osso circunjacente aos implantes curtos nos grupos com implantes regulares e curtos. No entanto, nesse mesmo contexto, gerou maior tensão ao osso circunjacente aos implantes regulares intermediários comparativamente aos grupos individualizados. Também favoreceu a diminuição das tensões ao osso circunjacente ao dente adjacente, quando na presença de proporção coroa/implante aumentada. O uso PSII apresentou-se vantajosa na diminuição das tensões na parte superior dos pilares e na área de conexão entre coroas, além do grupo controle, apenas com implantes regulares e próteses de proporção normal, sendo viável sua utilização neste contexto frente às vantagens clínicas não oferecidas pelas próteses esplintadas. / The use of dental implants in modern dentistry has gained prominence in oral rehabilitations. In cases of severe vertical bone loss, which is very much present in mandibular posterior areas, the use of short implants and reduced diameter is necessary. To maintain the occlusal plane level rehabilitation it is necessary the use of prostheses with increased crown/implant ratio , and it is important assess whether there is overhead of supporting structures, and befits splinting the rehabilitating infrastructure. One of the methods currently used to analyze the stress distribution in dentistry is the finite element method. Thus , this study has the overall objective to compare the biomechanical performance of prostheses, splinted (PSIE) or individualized (PSII) over Morse taper implants of regular and short length in the posterior area of the mandible. It were used three-dimensional geometric models of regular implants - ∅ 4x11 mm and short implants - ∅ 4x5 mm housed in representative edges of the posterior left mandibular hemi-arch tooth involving 34 teeth, designed in SolidWorks 2007 program. The 8 experimental groups were: control group E (3 regular implants rehabilitated with PSIE ), group 1E (2 regular and 1 short implants rehabilitated with PSIE) , 2E group (1 regular implant and 2 short implants rehabilitated with PSIE) and 3E group (3 short implants rehabilitated with PSIE); control group I (3 regular implants rehabilitated with PSII), group 1I (2 regular and 1 short implants rehabilitated with PSII), 2I group (1 regular implant and 2 short implants rehabilitated with PSII) and 3I Group (3 short implants rehabilitated with PSII); The pillars heights used for regular implants were of 3.5 mm and 0.8 mm for the short implants. Oblique forces (45° linguo-vestibular) were simulated in molars (365N) and premolars (200N). Qualitative and quantitative analysis of the distribution of maximum and minimum principal stresses (cortical and cancellous bone) and von Mises equivalent stress (implants, components and infrastructure) were made through the software AnsysWorkbench10.0. The results showed that the use of PSIE provided advantages and benefits regarding the stresses distribution in the elements involved in the system, being beneficial to all experimental groups of this study notoriously in the group with only short implants, reducing stresses in the surrounding bone to implants, especially in coverage. Also decreased the stresses on the implants surface, in the transmucosal abutments area, in the inner region of the infrastructure and its reach to the surrounding bone to short implants in groups with regular and short implants. However, in that respect, generated higher stresses to the surrounding bone of intermediate implants compared to the individualized groups. Also favoring a decrease of the stresses to surrounding bone adjacent to the tooth, in the presence of increased crown/implant ratio. The use PSII showed to be advantageous in reducing stresses on top of the abutments and the area of connection between crowns, and in the control group, only with regular implants and prostheses of normal crown/implant ratio, so it can be used in this context facing the clinical advantages not offered by splinted prostheses.
|
234 |
Estudo do desajuste angular e vertical em próteses fixas implantossuportadas por meio do MEF-3D /Gomes, Érica Alves. January 2009 (has links)
Resumo: Objetivo: A análise pelo método dos elementos finitos tridimensional foi utilizada para avaliar o efeito dos desajustes angular e vertical simulado em próteses fixas implantossuportadas parafusadas de 3 elementos, na resposta biomecânica do tecido ósseo peri-implantar, implantes e componentes protéticos. Material e método: Foram confeccionados 4 modelos tridimensionais, representativos de secção mandibular direita contendo um implante na região de segundo pré-molar (2oPM) e outro na região de segundo molar (2oM) ferulizados por uma prótese metalocerâmica implantossuportada parafusada de 3 elementos, diferenciados pelo tipo de desajuste protético, gerando os grupos: GC (grupo controle) - prótese totalmente adaptada aos implantes, DAU (desajuste angular unilateral) - prótese com desajuste angular unilateral de 100μm na região mesial do 2oM, DVU (desajuste vertical unilateral) - prótese com desajuste vertical unilateral de 100μm na região mesial do 2oM e DVT (desajuste vertical total) - prótese com desajuste vertical de 100μm em toda a plataforma de assentamento da infraestrutura no 2oM. Com a utilização do programa de elementos finitos Ansys® uma força vertical total de 400N foi distribuída em 12 pontos de parada cêntrica, sendo que cada molar recebeu um carregamento total de 150N e o 2oPM de 100N, gerando mapas de tensões. Resultados: Verificou-se que a distribuição e os valores de tensões para o tecido ósseo peri-implantar foram similares para todos os grupos. Os grupos com desajustes alteraram o padrão de distribuição e elevaram a magnitude das tensões em relação ao grupo GC. No grupo DAU os maiores valores de tensões foram observados no corpo do implante e parafuso de retenção. Já nos grupos DVU e DVT elevados valores de tensões foram encontrados na plataforma de assentamento da infraestrutura... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose: The three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in 3-piece implant-supported and screw-retained fixed prostheses on biomechanical response in peri-implant bone tissue, implants and prosthetic components. Material and method: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of second premolar (2°PM) and other in the region of second molar (2°M). The implants were splinted by a 3- piece implant-supported metal ceramic prosthesis and differed according to the type of misfit as represented by the groups: CG (control group) - prosthesis with complete fit to the implants, UAM (unilateral angular misfit) - prosthesis presenting unilateral angular misfit of 100μm in the mesial region of the 2°M, UVM (unilateral vertical misfit) - prosthesis presenting unilateral vertical misfit of 100μm in the mesial region of the 2°M, and TVM (total vertical misfit) - prosthesis presenting total vertical misfit of 100μm in the platform of the framework in the 2°M. A vertical load of 400N was distributed and applied on 12 centric points by the software Ansys®. So, vertical loading of 150N was applied on each molar while vertical load of 100N was applied on the 2°PM. Stress maps were obtained by processing of the finite element software. Results: The stress values and distribution on peri-implant bone tissue were similar for all groups. The groups presenting misfit exhibited different distribution pattern and increased stress magnitude in comparison to the group CG. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework... (Complete abstract click electronic access below) / Orientador: Wirley Gonçalves Assunção / Coorientador: Edson Antônio Capello Sousa / Banca: Paulo Henrique dos Santos / Banca: Ricardo Faria Ribeiro / Banca: João Neudenir Arioli Filho / Doutor
|
235 |
A produ??o das perdas dent?rias: narrativas de usu?rios do SUSDantas, Jussara de Azevedo 27 August 2008 (has links)
Made available in DSpace on 2014-12-17T15:30:52Z (GMT). No. of bitstreams: 1
JussaraAD.pdf: 601035 bytes, checksum: cffe252603743caec8889a83b0645aab (MD5)
Previous issue date: 2008-08-27 / For a complete comprehension of the effect of tooth loss is necessary to listen to the patients that have it. This study, of qualitative approach, investigate, in the dental history of users of SUS, listening to his/her experiences with the services of dental care, the reason that lead his/her to dental lost and the repercussion of this in his/her life. The collect of data was made by narrative interview, obeying to a pre-defined schema. The subjects interviewed were six (three of urban zone and three of rural zone), all of them were users of Family Health Units. The criterions of inclusion were the followings: the presence of tooth lost (total lost in both dental arch or in one of them, or partial lost in at least six elements in one of the arches); age between 25 and 59; male or female; to live in municipal district of S?o Tom?/RN or Natal/RN. Based on previous interviews was elaborated the odontological history of each patient. Such narratives, systemized in odontological history, were analyzed taking as base the
studies of Souza71 and the proposal of Schutze, suggested for Jovchelovitch, Bauer34. The results show that toothache was the main reason for the search of odontological care. The patients confront the ache with home-made medicaments, allopathic ones, and searching for dental care. The searching for exodontics was stimulated for geographic access difficulties or
for repressed demand, which as a result produced the aggravation of the lesions and the discredit in restoration s treatment. The self-care practice of tooth-brush with ju? or toothpaste and the controlled ingestion of sugar was not sufficient to avoid dental lost. Guilty sentiments were identified in relation with lack of care with teeth. The acceptance of dental lost as a natural factor is an important motivation in lack of pain and in the belief that it was a simple part of life in old age. Life with dental prosthesis makes clear the difference between which was natural and which was unnatural, and difficulties with the prosthesis appeared. The limitation of the prosthesis in its functional aspect can be compensated by esthetic restitution,
making possible smiling expression. Starting with this study and considering the high number of dental lost, mainly in low-rent population, which live with toothless limitations or bad-quality prosthesis which do not rehabilitate adequately, we suggested the realization of qualitative researches which include, also, another actors in heath care services such as
professionals and administrators / A compreens?o ampliada dos efeitos da perda dent?ria exige escuta dos sujeitos que a experimenta. Este estudo, de abordagem qualitativa, investigou, na hist?ria odontol?gica de usu?rios do SUS, a partir do relato de suas experi?ncias com os servi?os de sa?de bucal, os motivos que os levaram ? perda dent?ria e as repercuss?es desta em suas vidas. A coleta de
dados foi realizada por meio da t?cnica de entrevista narrativa, adaptada, utilizando-se roteiro semi-estruturado. Os sujeitos entrevistados, num total de seis (tr?s da zona urbana e tr?s da zona rural), foram usu?rios de Unidades de Sa?de da Fam?lia. Consideraram-se os seguintes crit?rios de inclus?o: presen?a de desdentamento (perda total em ambas as arcadas, ou em uma delas, ou perda parcial a partir de seis elementos em uma das arcadas); idade ente 25 e 59 anos; qualquer g?nero; ser morador dos munic?pios de S?o Tom?/RN e Natal/RN. A partir do conte?do das entrevistas foi elaborada a hist?ria odontol?gica de cada entrevistado. Tais narrativas, sistematizadas em hist?rias odontol?gicas, foram analisadas com base em estudo de Souza e na proposta de Sch?tze, sugerida por Jovchelovitch, Bauer. Os resultados indicaram que a experi?ncia de dor foi o principal motivo pela procura por assist?ncia odontol?gica. As formas de enfrentamento da dor deram-se pelo uso de medica??es caseiras e alop?ticas e pela busca do servi?o de sa?de. A procura pela exodontia foi favorecida pela
dificuldade de acesso geogr?fico ou pela grande demanda reprimida, o que produziu agravamento das les?es e descr?dito na efic?cia do tratamento restaurador. A pr?tica do autocuidado atrav?s da escova??o com ju? ou creme dental e o controle do consumo de a??car n?o foram suficientes para evitar a perda dent?ria. Foram identificados sentimentos de culpa
relacionados ? falta de cuidado. A aceita??o da perda dent?ria como natural teve forte rela??o com a garantia de aus?ncia de dor e a cren?a de fazer parte do processo de envelhecimento. A conviv?ncia das pessoas com a pr?tese dent?ria mostrou a diferen?a entre o que era natural e o que era artificial e, a partir da?, foram aparecendo situa??es de estranhamento com a
pr?tese. A limita??o da pr?tese quanto ao aspecto funcional pode ser compensada pela restitui??o da est?tica, ao possibilitar a express?o do sorriso. A partir deste estudo e considerando o elevado n?mero de perdas dent?rias, especialmente em popula??es de menor poder aquisitivo, que convivem com limita??es pr?prias da condi??o de desdentado e ou com pr?teses de m? qualidade que n?o reabilitam, adequadamente, sugere-se a realiza??o de pesquisas de abordagem qualitativa que inclua, tamb?m, outros atores implicados na produ??o de cuidados e servi?os de sa?de profissionais e gestores
|
236 |
Satisfa??o dos usu?rios e qualidade dos tratamentos prot?ticos realizados nos Centros de Especialidades Odontol?gicas da Grande Natal RNCosta, Anna Paula Serejo da 18 March 2011 (has links)
Made available in DSpace on 2014-12-17T15:30:56Z (GMT). No. of bitstreams: 1
AnnaPSC_DISSERT.pdf: 1055344 bytes, checksum: 3820065b4404d2eed0b9f94f68a004b1 (MD5)
Previous issue date: 2011-03-18 / Aim: To evaluate user satisfaction and quality of prosthetic treatments performed in specialized dental clinics (CEOs) of Natal Metropolitan Region - RN. Methods: Cross-sectional study with subjects who underwent prosthetic CEOs in the cities of Natal, Maca?ba, Parnamirim and Sao Goncalo do Amarante in the period 2007 to 2009. Data collection was performed by questionnaire, clinical examination of the oral cavity and examination of fabricated denture. This analysis involved the following aspects: retention, stability, aesthetics and prosthesis fixation. The variables are presented by means of absolute numbers and proportions. The determination of the association between the independent and dependent variables was conducted by the association of Chi-square test and Fisher exact test. Results: A total of 149 users, totaling 233 conventional dentures (148 upper and 85 lower). Most patients (56.4%) were rehabilitated with conventional complete dentures. The technical quality of the denture was regarded as satisfactory in the majority (52.7%), whereas the inferior dentures were rated as unsatisfactory in 90.5% of cases. Satisfaction with the prosthesis was 69.1% (N = 103). The average time to begin treatment was 3 months to receive while the prosthesis was 4 months old. The presence of injury from the upper prosthesis occurred in 21.5% of cases (N = 32), candidiasis being the most frequent (N = 18). The technical quality of the upper prosthesis (p=0,041), as well as retention (p=0,002) and stability (p<0,001) were significantly associated with user satisfaction. Conclusions: The specialized
Dental clinics has been fulfilling its role of providing treatment of intermediate complexity for low-income population with the majority of satisfield patients, even when their dentures have problems of technical quality / Objetivo: Avaliar a satisfa??o dos usu?rios e a qualidade dos tratamentos prot?ticos realizados nos Centros de Especialidades Odontol?gicas (CEOs) da Grande Natal-RN. M?todos: Estudo transversal com os indiv?duos que realizaram tratamento prot?tico nos CEOs dos munic?pios de Natal, Maca?ba, Parnamirim e S?o Gon?alo do Amarante no per?odo de 2007 a 2009. A coleta de dados foi realizada atrav?s de question?rio, do exame cl?nico da cavidade oral dos usu?rios e da pr?tese dent?ria confeccionada. Tal an?lise envolveu os seguintes aspectos: reten??o, estabilidade, fixa??o e est?tica das pr?teses. As vari?veis s?o apresentadas de maneira descritiva por meio de n?meros absolutos e propor??es. A determina??o da associa??o entre as vari?veis independentes e as vari?veis dependentes foi realizada pelo teste de associa??o qui-quadrado e o teste exato de Fisher. Resultados: Foram examinados 149 usu?rios, totalizando 233 pr?teses totais convencionais (148 superiores e 85 inferiores). A maioria dos pacientes (56,4%) foi reabilitada com pr?teses totais convencionais bimaxilares. A qualidade t?cnica das pr?teses totais superiores foi tida como satisfat?ria na sua maioria (52,7%), enquanto que as pr?teses inferiores foram classificadas como insatisfat?rias em 90,5% dos casos. A satisfa??o com as pr?teses foi de 69,1% (N=103). O tempo m?dio para come?ar o tratamento foi de 3 meses enquanto que para receber a pr?tese foi de 4 meses. A presen?a de les?o proveniente da pr?tese superior ocorreu em 21,5% dos casos (N=32), sendo a candid?ase a de maior ocorr?ncia (N=18). A qualidade t?cnica das pr?teses superiores (p=0,041), bem como a reten??o (p=0,002) e a estabilidade (p<0,001) apresentaram associa??o significativa com a satisfa??o do usu?rio. Conclus?es: Os Centros de Especialidades Odontol?gicas vem cumprindo o seu papel de fornecer tratamento de m?dia complexidade para a popula??o de baixa renda, estando a maioria dos pacientes satisfeitos, mesmo quando suas pr?teses apresentam problemas de qualidade t?cnica
|
237 |
Relação da distância interimplantar e altura do ponto de contato na formação de papilas gengivais: estudo em cães / Influence of interimplantar distance and height from the point of contact in the formation of gingival papilae: a study in dogsDiogo Rodrigues Cruvinel 24 April 2009 (has links)
Os implantes dentais são considerados uma modalidade de tratamento bastante previsível para a reposição de dentes perdidos. Os implantes osseointegráveis principalmente quando colocados em regiões anteriores devem oferecer, além de excelente função, ótima estética, e fonética. Sendo que o critério para o sucesso envolve o estabelecimento do contorno de tecido mole, apresentando a área interproximal intacta. O propósito deste estudo foi avaliar a influência das diferentes distâncias (3 e 5 mm) entre a crista óssea e ponto de contato interdental, na formação de papila gengival associado à presença de diferentes distâncias (2 e 3 mm) entre implantes contíguos e na região de extremo livre mesial e distal. Foram selecionados para o experimento 8 cães adultos jovens e executada a exodontia dos 4 pré-molares mandibulares: p1, p2, p3, p4, para cada hemi-mandibula. Três meses após as exodontias foram colocados 3 implantes Replace Select Tapered com superfície tratada e dimensões de 4,3 X 10 mm, em cada hemimandibula animal. O primeiro implante foi colocado a 10 mm da distal do canino remanescente, o segundo (intermediário) foi colocado a 2 mm do primeiro e o terceiro implante (posterior) foi colocado a 3 mm do segundo. Foi iniciada a reabilitação protética, no dia da colocação dos implantes. Primeiramente foi feita a moldagem para a confecção das próteses metálicas. As coroas metálicas definitivas, confeccionadas, apresentaram distância do ponto de contato à crista óssea de 3 e 5 mm lado esquerdo e direito respectivamente. Ao completar 12 semanas pós-colocação das próteses definitivas, os animais foram sedados e as análises clínicas foram executadas. Esta avaliação foi feita a partir da utilização de um compasso de pontas secas, medindo as distâncias entre os pontos de contato e as pontas das papilas (PC - P) e dos pontos de contato aos extremos livres mesial e distal (PC - ELM e PC ELD respectivamente). O delineamento das situações experimentais foi executado levando em consideração as associações das diferentes distâncias interimplantar com as diferentes distâncias do ponto de contanto a crista óssea, assim encontramos a seguinte disposição: Situação 01 (PC3A) Distância do ponto de contato a gengiva do extremo livre mesial, do lado esquerdo; Situação 02 (PC3B) Distância do ponto de contato, a gengiva interproximal sendo à distância interimplantar de 2 mm, lado esquerdo da mandíbula; Situação 03 (PC3C) Distância do ponto de contato, a gengiva interproximal sendo a distância interimplantar de 3 mm, lado esquerdo da mandíbula; Situação 04 (PC3D) Distância do ponto de contato a gengiva do extremo livre distal, do lado esquerdo Situação 05 (PC5A) Distância do ponto de contato a gengiva do extremo livre mesial, do lado direito; Situação 06 (PC5C) Distância do ponto de, a gengiva interproximal sendo a distância interimplantar de 3 mm, lado direito da mandíbula; Situação 07 (PC5B) Distância do ponto de contato, a gengiva interproximal sendo a distância interimplantar de 2 mm, lado direito da mandíbula e Situação 08 (PC5D) Distância do ponto de contato a gengiva do extremo livre distal, do lado direito. Ao analisar as medias das alturas gengivais temos: PC3A a média de 2,9±0,5 mm; PC3D 2,5±0,5 mm; PC3B 1,8±0,6 mm; PC3C 2,0±0,8 mm; PC5A 3,0±0,5 mm; PC5D 3,5±0,4 mm; PC5C 3,6±0,4 mm e PC5B 3,9±0,7 mm. Como as premissas de aderência à distribuição normal, independência entre os indivíduos estudados e pareamento entre as diferentes etapas foram cumpridas, empregou-se a análise de variância (ANOVA) para mensurações repetidas, a dois fatores. Nos casos em que a ANOVA encontrou diferença entre as situações testadas, uma comparação a posteriori foi executada por meio do teste de Bonferroni. O nível de significância empregado para todos os testes foi de 0,05 (5%). Logo as distâncias de 2,0 e 3,0 mm entre implantes contíguos não apresentaram diferença significativa na formação de papila quando as restaurações protéticas são confeccionadas com 3 ou 5 mm de distância entre o ponto de contato e a crista óssea. Considerando a provável reabsorção óssea em ambos os grupos, quando a distância do ponto de contato à crista óssea foi inicialmente de 3 mm esta condição apresentou melhores resultados na formação de papilas do que a distância de 5 mm em todas as situações estudadas. A presença do ponto de contato de 3 mm influência positivamente na formação de papila, quando comparada com as regiões de extremo livre. / The dental implants are considered a form of treatment rather predictable for replacement of lost teeth Implants should offer, as well as excellent function, aesthetics and phonetics great, especially when placed in anterior regions, where the criterion for success involves the establishment contour of the soft tissue, showing the area intact interproximal The purpose of this study was to evaluate the influence of different distances between the bone crest and interdentally contact point, with 3 and 5 mm, the formation of gingival papilla associated with the presence of different distances of 2 and 3 mm between implants and the adjacent region of mesial and distal end free. Were selected for the experiment 08 dogs and young adults performed the extraction of the 4 pre molars mandibles: p1, p2, p3, p4, for each hemi-mandible. Three months after the tooth extractions were placed 3 Replace Select Tapered implants with treated surface and dimensions of 4.3 X 10 mm in each animal hemi mandibles. The first implant was placed at 10 mm distal of the canine left, the second (middle) was placed at 2 mm from the first and third implant (back) was placed at 3 mm from the second. Prosthetics rehabilitation has begun on the day of the placement of implants. First was the casting for the manufacture of metal stents, since the provisional prostheses were made of acrylic resin so that the distance between the point of contact and the bone crest is 3 mm on the left side of the mandible and 5 mm on the right. The final metal crowns, made, made from the point of contact to bone crest of 3 and 5 mm. After completing 12 weeks after placement of final prosthesis, the animals were sedated and the clinical tests were performed. This evaluation was made from the use of a dry bar for tips, measuring the distances between the points of contact and the tips of the papillae (PC - P) and the contact points of the mesial and distal ends free (PC - PC and ELM - ELD respectively). The design of the experimental situations was implemented taking into account the associations of different distances interimplantar with different distances from the long bone crest, we found the following provision: Location - 01 (PC3A) Distance from the point of contact to end the free gingiva mesial to the left; Situation - 02 (PC3B) Distance from the point of contact, the gingival interproximal distance being interimplantar of 2 mm, the left side of the mandible; Situation - 03 (PC3C) Distance from the point of contact, the gingival interproximal and interimplantar a distance of 3 mm, the left side of the mandible; Situation - 04 (PC3D) Distance from the point of contact to the extreme free gingival distal to the left position - 05 (PC5A) Distance from the point of contact to the extreme free gingival mesial on the right side; Situation - 06 (PC5C) distance from the interproximal gingival interimplantar the distance of 3 mm, right side of the jaw; Situation - 07 (PC5B) Distance from the point of contact, the gingival interproximal the distance interimplantar of 2 mm, the right side of the mandible and Situation - 08 (PC5D) Distance from the point of contact to free distal end of the gingival on the right side. In examining the measures of gingival heights are: PC3A an average of 2.9 ± 0.5 mm; PC3D 2.5 ± 0.5 mm; PC3B 1.8 ± 0.6 mm; PC3C 2.0 ± 0.8 mm; PC5A 3.0 ± 0.5 mm; PC5D 3.5 ± 0.4 mm; PC5C 3.6 ± 0.4 mm and PC5B 3.9 ± 0.7 mm. As adherence to the assumptions of normal distribution, independence among the subjects studied and matching between the different stages have been completed, using the analysis of variance (ANOVA) for repeated measurements, the two factors. Where ANOVA found the difference between the conditions tested, a posteriori comparison was performed using the Bonferroni test. The significance level used for all tests was 0.05 (5%). Once the distances of 2.0 and 3.0 mm between adjacent implants showed no significant difference in the formation of the papilla when prosthetic restorations are made with 3 or 5 mm distance between the point of contact and the bone crest. Considering the probable bone resorption in both groups, where the distance from the point of contact to the bone crest was originally the condition of 3 mm showed better results in the formation of papillae than the distance of 5 mm in all cases studied. The presence of the point of contact 3-mm positively influence the formation of papilla, when compared with regions of extreme freedom.
|
238 |
Avaliação de overdentures mandibulares com diferentes sistemas de retenção: análise fotoelástica da transmissão de tensões e efeito de carga cíclica na força de retenção / Evaluation of mandibular overdentures with different attachments systems: Photoelastic stress analysis and effect of cyclic loading on retention forceFábio Afrânio de Aguiar Junior 01 July 2013 (has links)
O surgimento dos implantes osseointegrados melhorou a qualidade de vida de pacientes edêntulos. Seu uso favorece retenção e estabilidade, gerando maior eficiência mastigatória e conforto. O objetivo deste estudo foi avaliar manutenção da força de retenção e padrões de tensões gerados na mandíbula em overdentures confeccionadas com dois sistemas de retenção retidas por 2 ou 3 implantes. Teste de carga cíclica e análise fotoelástica de tensões foram realizados. Para o teste de carga cíclica foram utilizados modelos representativos de mandíbulas desdentadas e os grupos analisados foram: A) 2 implantes com barra clipe; B) 3 implantes com barra clipe; C) 2 implantes com barra clipe e bola/o\'ring nas extremidades; D) 3 implantes com barra clipe e bola/o\'ring nas extremidades. Cinco espécimes por grupo foram submetidos à ciclagem e 5 permaneceram imersos na máquina de ciclagem (controle). As leituras de força de retenção foram realizadas por ensaio de tração em máquina de ensaios universal antes da ciclagem e a cada 500 mil ciclos. A ciclagem foi realizada com frequência de 1,8 Hz, carga de 130 N, por 2 milhões de ciclos. Para a aplicação de carga, foram feitas pontas correspondentes à arcada antagonista unilateral posterior. Os dados obtidos foram analisados estatisticamente pelo modelo linear de efeitos mistos. Para a análise fotoelástica, foi feito um modelo mestre curvo em resina acrílica. O modelo foi preparado para conter cinco implantes, paralelos, distribuídos na região interforaminal. Grupo com 4 implantes com barra clipe e o\'rings nas extremidades foi incluído como controle. Prótese total foi confeccionada e usada em todos os grupos. A cada grupo, nova captura de retentores foi realizada. Para obtenção dos modelos fotoelásticos, foram confeccionados moldes em silicone do modelo mestre. A verificação das tensões em torno dos implantes foi realizada por meio de análise fotoelástica qualitativa de transmissão sob aplicação de carga cêntrica estática de 50 N. Diferentes tipos de pontas e locais de aplicação de carga foram usados. Os resultados demonstraram que carga cíclica influencia na perda de retenção overdentures mandibulares. Comparando grupos controle e teste, observou-se que os grupos com três implantes apresentaram maior influência da ciclagem na perda de retenção. Os sistemas de retenção estudados apresentaram comportamentos diferentes até um milhão de ciclos, após não houve diferença quanto à manutenção de retenção. Todos os grupos mantiveram retenção satisfatória ao final da ciclagem. Três implantes apresentaram maior tensão ao redor dos implantes e pouca ou nenhuma sobre o rebordo. Nos grupos com dois implantes, aplicação de carga posterior gerou tensões no rebordo alveolar e implantes. Grupos com extensões distais evidenciaram uma maior tensão ao redor dos implantes que os sem extensão. / The appearance of osseointegrated dental implants improved the quality of life of fully edentulous patients. Implants promote retention and stability, producing higher masticatory efficiency and comfort. The aim of this study was analyze the retention maintenance and the stress pattern generated by two or three implants-supported mandibular overdentures with two attachments systems. Cyclic loading test and photoelastic stress analysis were performed. For the cyclic loading test, edentulous mandibular models were used. The analyzed groups were: A) 2 implants with bar clip; B) 3 implants with bar clip; C) 2 implants with bar clip and balls/o\'rings in the extremity; D) 3 implants with bar clip and balls/o\'rings in the extremity. Five specimens per group were submitted to cyclic loading and five were kept immersed inside the test machine (control group). The measurements of retention force were performed by tensile test in a universal testing machine before cyclic loading and after each 500 thousands cycles. The cycling was performed with frequency of 1.8 Hz, loading of 130 N, up to two million cycles. For the load application, tips corresponding to posterior unilateral antagonist teeth were produced. Data were statistically analyzed by linear mixed-effects model. For the photoelastic analysis, a curved master model was produced in acrylic resin. The model contained five parallel implants, distributed in interforaminal area. A group with 4 implants splinted with bar clip and balls/o\'rings in the extremity was included as a control. Complete denture was made and used in all groups. In each group, incorporating of new attachments was performed. For the obtainment of photoelastic models, silicone impression of the master model was performed. The assessment of stress around implants was done through quantitative transmission photoelastic analysis under static centric load application of 50 N. Different sorts of tips and load application places were used. The results showed that cyclic load influences the retention loss of mandibular overdentures. Comparing test and control groups, it was observed that groups with three implants showed higher influence of cyclic loading in retention loss. The studied attachments systems showed different behaviors up to one million cycles, after that there was not difference in the maintenance of retention. All groups had satisfactory retention at the end of cycling. Groups with three implants showed higher stress around implants and lower or none on alveolar ridge. In groups with two implants, load application on posterior area caused stress on alveolar ridge and implants. Groups with distal extensions demonstrated higher stress around implants than groups without extension.
|
239 |
Analise fotoelastica da distribuição de tensões em dois sistemas de proteses mandibulares sobre implantes : barra distal e solda a laser / Photoelastic analysis of the distribution of the tensions in two systems of mandibular prosthesis over implants : distal bar and laser weldingSalles, Angelo Emilio Barroso de 12 August 2018 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T16:14:35Z (GMT). No. of bitstreams: 1
Salles_AngeloEmilioBarrosode_M.pdf: 10746117 bytes, checksum: 7a6d08147fb33c8d235cc7df5f8be032 (MD5)
Previous issue date: 2008 / Resumo: Este estudo avaliou por meio de análise fotoelástica, a distribuição in vitro das tensões geradas na interface "osso/implante" em próteses mandibulares, tipo protocolo, comparando duas técnicas de confecção: Solda a laser e Barra Distal (Neodent, Curitiba - PR) onde não se utiliza infra-estrutura metálica. Foram confeccionadas duas próteses com design similares (uma para cada técnica), sobre uma matriz metálica simulando um arco mandibular edêntulo, onde foram instaladas cinco réplicas de implantes de corpo único (GT- Neodent, Curitiba - PR). A partir de um molde de silicone de duplicação (Silibor - Clássico Artigos Odontológicos Ltda.) foi confeccionado um modelo em resina fotoelástica (Araldite GY279BR - Araltec Produtos Químicos Ltda. Guarulhos - SP) com cinco implantes GT (Neodent, Curitiba - PR) incorporados. Após a instalação de cada prótese sobre o modelo fotoelástico, utilizando 10 N/cm para aperto dos parafusos, foi realizada análise fotoelástica. Em seguida, foi aplicada carga oclusal de 100 N em toda extensão de cada prótese, com auxílio de uma placa metálica posicionada sobre a face oclusal dos dentes, e então realizada nova análise das tensões. Estas análises foram executadas com o auxílio de um polariscópio circular acoplado a uma máquina fotográfica digital (H1 - Sony, Japão), que permitiu a visualização das franjas e registrou através de fotografias digitais o comportamento das mesmas ao redor dos implantes no modelo fotoelástico. De acordo com os resultados, concluiu-se que a técnica utilizando Barra Distal distribuiu melhor, e transmitiu com menos intensidade, após o aperto dos parafusos, as tensões geradas na interface "osso/implantes" do que a técnica utilizando solda a laser. No entanto, ocorreu o inverso após o carregamento oclusal. / Abstract: The aim of this study was to evaluate through photoelastic analysis, the in vitro distribution of the generated tensions in the "bone/ implant" interface in mandibular prostheses, protocol type, comparing two different working techniques: the idealized by Branemark and Distal Bar (Neodent, Curitiba - PR) where framework is not used. Two similar prostheses were made (one for each technique), on a metal matrix simulating an edentulous mandible, where five replications of single body implant were installed (GT-Neodent, Curitiba - PR). From a silicone mold for duplication (Silibor - Classico Artigos Odontológicos Ltda.), a model in photoelastic resin was created (Araldite GY279BR - Araltec Produtos Quimicos Ltda., Guarulhos - SP) with five GT implants (Neodent, Curitiba - PR) embedded. After the installation of each prosthesis on the photoelastic model, using 10 N/cm for tightening the screws, a photoelastic analysis was performed. Then a 100 N occlusion load was applied throughout each prosthesis extension with the help of a metal plate positioned on the occlusal face of the teeth, and then a new analysis of the tensions was conducted. These analyses were performed with the help of a circular polariscope attached to a digital camera (H1 - Sony, Japan), which allowed the visualization of the fringes and recorded by digital photos the behaviour of the implants. According to the results, it was concluded that the Distal Bar technique distributed better, and transmitted with less intensity, after the tightening of the screws, the generated tensions to the system "bone/implants" than the laser welding. However, it happened the opposite after the occlusal load. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
240 |
Avaliação da microestrutura óssea de sítios implantares e fatores relacionados às alterações no nível ósseo marginal e estabilidade de implantes dentários: estudo clínico prospectivo / Assessment of microstructure of jawbone sites and factors related to the changes on marginal bone level and dental implant stability: prospective clinical studyDias, Danilo Rocha 15 July 2013 (has links)
Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-12T17:49:23Z
No. of bitstreams: 1
Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) / Rejected by Jaqueline Silva (jtas29@gmail.com), reason: on 2014-12-12T17:49:32Z (GMT) / Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-12T19:43:01Z
No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-12-16T09:25:37Z (GMT) No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) / Made available in DSpace on 2014-12-16T09:25:37Z (GMT). No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5)
Previous issue date: 2013-07-15 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Bone characteristics influence surgical/prosthetic planning of implant treatment, but it is not clear their influence on longitudinal outcomes. This study aimed to investigate the association between jawbone microstructure and changes on marginal bone level (MBL) and implant stability (IS) after loading, in a 1-year follow-up. Forty-one volunteers received 97 dental implants, installed in bone sites classified from 1 to 4, according to Leckholm & Zarb (1985). Cortical bone thickness was measured on computed tomography images. Histomorphometric and microtomographic analyses were performed in bone specimens obtained by using a trephine bur, at first drilling. Peak insertion torque (PIT) and implant stability quotient (ISQ) measured by resonance frequency analysis (RFA) were registered at implant insertion. Periapical radiographs were standardized to measure the MBL, and were taken at three moments, when the ISQ was also measured: at uncovering stage, at loading and at 1-year follow-up. Agreement analysis between histomorphometry and microcomputed tomography (microCT) showed that these methods are complementary, but not interchangeably. Association tests revealed that ISQ changes were not affected by MBL changes. Bone type 4 (according L&Z) presented higher changes on ISQ, especially during osseointegration. Microstructure parameters (histomorphometric and microCT parameters) and cortical thickness did not influence ISQ changes and MBL changes. These results suggest that bone characteristics influence primary implant stability, but do not predict implant success after osseointegration. / Características do tecido ósseo influenciam o planejamento cirúrgico/protético dos implantes dentários, mas não está clara sua relação com o resultado longitudinal do tratamento com implantes. O objetivo deste estudo foi investigar a associação entre microestrutura óssea de sítios implantares da maxila e mandíbula, as alterações de nível ósseo marginal (MBL) e a estabilidade dos implantes (IS) até o período de 1 ano após a aplicação de carga oclusal. Quarenta e um pacientes receberam 97 implantes dentários, instalados em sítios ósseos classificados como tipos 1 a 4, de acordo com a classificação de Leckholm & Zarb (1985). A espessura de osso cortical foi mensurada em imagens de tomografia computadorizada. Análises microtomográficas e histomorfométricas foram realizadas em espécimes ósseos obtidos com trefina na primeira perfuração para instalação dos implantes. Torque de inserção final (PIT) e quociente de estabilidade do implante (ISQ) medido por análise de freqüência de ressonância (RFA) foram registrados durante a instalação dos implantes. Radiografias periapicais padronizadas para mensuração do MBL foram obtidas em tres momentos, quando novos registros do ISQ foram também realizados: durante a cirurgia de reabertura, na instalação das próteses e 1 ano após aplicação da carga oclusal. A análise de concordância entre os métodos de microtomografia computadorizada (microCT) e histomorfometria, mostrou que estes métodos são complementares, mas não intercambiáveis. Testes de associação mostraram que as alterações na IS não foram afetadas pelas alterações no MBL. Ossos classificados como tipo 4 apresentaram as maiores alterações da IS, principalmente durante a osseointegração. Os parâmetros microestruturais (parâmetros microtomográficos e histomorfométricos) e a espessura de cortical não influenciaram as alterações de IS e do MBL. Estes resultados sugerem que as características do sítio ósseo influenciam a estabilidade primária, mas não são preditores do sucesso dos implantes após a osseointegração.
|
Page generated in 0.0926 seconds