• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 115
  • 44
  • 3
  • 2
  • Tagged with
  • 164
  • 164
  • 73
  • 60
  • 57
  • 55
  • 55
  • 49
  • 37
  • 33
  • 29
  • 25
  • 25
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Avaliação por meio da tomografia computadorizada de feixe cônico da disponibilidade óssea da sínfise mandibular

Bernini, Gabriel Fiorelli 08 November 2013 (has links)
Introdução: As características anatômicas dos ossos maxilares e suas possíveis variações apresentam um grande interesse, pela crescente demanda por procedimentos cirúrgicos como cirurgias ortognáticas e colocação de implantes osseointegráveis. Nessa perspectiva, existe particular interesse em relação aos enxertos ósseos autógenos, considerando-se a necessidade crescente de sua aplicação associados aos implantes, naqueles indivíduos com reabsorções e defeitos ósseos. O conhecimento da anatomia e do conteúdo da área inter-forames mentuais e possíveis implicações clínicas são ainda controversos e pouco documentados. A tomografia computadorizada de feixe cônico (TCFC) possibilita a reformatação da imagem em três dimensões permitindo um estudo mais detalhado da região da sínfise mandibular. Objetivo: Avaliar as dimensões da sínfise mandibular para enxertia óssea, nas reformatações panorâmicas e parassagitais obtidas por TCFC. Material e Métodos: Foram determinadas: a distância inter-forames mentuais, a distância entre a cortical vestibular e a cortical lingual e a distância entre o ápice dos dentes anteriores inferiores e a base da mandíbula. Será avaliada também a presença de alças anteriores do nervo mentual e extensão anterior das mesmas nas duas reformatações. Utilizou-se 200 TCFC, de homens e mulheres adultos, proveniente dos arquivos de imagem do Departamento de Estomatologia da Faculdade de Odontologia de Bauru/USP. A visibilidade e as medições da sínfise mandibular foram avaliadas pela TCFC através da ferramenta de distância do i-CAT Vision Software nas reformatações panorâmica (RfPan) e parassagital (RfPsg) determinando assim suas medidas para realização de cirurgia para remoção de enxerto ósseo. Resultados: A média das medidas da distância inter-forames mentuais, para obter a largura da área doadora, foi de 42,27 mm; entre a cortical vestibular externa e a cortical lingual externa, para obter a espessura total da área doadora foi de 10,31 mm para o lado direito, 10,07 mm para o lado esquerdo e 10,5 mm para a linha média; entre a cortical vestibular interna e a cortical lingual interna, para obter a espessura do trabeculado medular da área doadora foi de 5,82 mm para o lado direito, 5,54 mm para o lado esquerdo e 5,93 mm para a linha média; entre o ápice dos dentes anteriores inferiores, preferencialmente os caninos, e a base da mandíbula, para obter a altura da área doadora foi de 13,03 mm para o lado direito, 12,87 mm para o lado esquerdo e 17,86 para a linha média. A alça anterior do forame mentual foi visualizada em 47 das 200 imagens de TCFC, ou 23,5% delas, sendo em 36 (18%) do lado direito e do lado esquerdo, 3 (1,5%) apenas do lado direito e 8 apenas do lado esquerdo (4%). A média das medidas da distância entre a alça anterior e a base da mandíbula foi de 7,02 mm para o lado direito e 6,73 mm para o lado esquerdo. Conclusões: A sínfise mandibular pode fornecer um volume de 632,51 mm3 (32,47 x 4,87 x 4 mm), quando utilizarmos as novas margens de segurança preconizadas, ou até 1.344,13 mm3 (32,47 x 7,87 x 5,26 mm), quando consideradas as margens de segurança previamente descritas. Esses valores mostram a disponibilidade óssea da sínfise mandibular como uma das principais opções para remoção de enxerto autógeno em reconstruções parciais dos maxilares. / Introduction: The anatomical characteristics of the maxillary bones and their possible variations present a great interest by increasing demand for surgical procedures such as orthognathic surgery and placement of osseointegrated implants. From this perspective, there is particular interest in relation to autogenous bone grafts, considering the growing need for their application associated with implants in those individuals with resorption and bone defects. The knowledge of the anatomy and content of the mental inter-foramina area and possible clinical implications are still controversial and poorly documented. Cone beam computed tomography (CBCT) allows reformatting of a three-dimensional image allowing a more detailed study of the mandibular symphysis region. Objective: To assess the dimensions of the mandibular symphysis for bone grafting in panoramic and parasagittal reconstructions obtained by CBCT. Material and Methods: Determined were: the mental inter-foramina distance, the distance between the buccal cortical and lingual cortical and the distance between the apex of the mandibular anterior teeth and the base of the mandibula. The presence of anterior loops of the mental nerve and anterior extension of the same in the two reconstructions will also be evaluated. Two hundred CBCT`s from adult men and women were utilized, obtained from the image files of the Department of Stomatology, Bauru School of Dentistry / USP. The visibility and measurements of the mandibular symphysis were evaluated by CBCT through the distance tool from the i-CAT Vision Software in panoramic (RfPan) and parasagittal (RfPsg) reconstructions, thus determining their measurements to perform surgery for the removal of the bone graft. Results: The average measurement of the mental inter-foramina distance, to obtain the width of the donor area was 42.27 mm between the outer buccal cortical and external lingual cortical, and to obtain the total thickness of the donor area was 10.31 mm to the right side, 10.07 mm to the left side and 10.5 mm to the midline; between the internal buccal cortical and internal lingual cortical to obtain the thickness of the trabecular medullary of the donor area was 5.82 mm to the right side, 5.54 mm to the left side and to 5.93 mm to the midline, between the apex of the anterior teeth, preferably canines and the base of the mandibula to obtain the height of the donor area was 13.03 mm to the right side, 12.87 mm to the left and 17.86 to the midline. The anterior loop of the mental foramen was visualized in 47 out of 200 CBCT images, or 23.5%, and in 36 (18%) of the right and left sides, 3 (1.5%) only on the right side and 8 only the left side (4%). The average measure of the distance between the anterior loop and the base of the mandibula is 7.02 mm to the right side and 6.73 mm to the left side. Conclusions: The mandibular symphysis can provide a volume of 632.51 mm3 (32.47 x 4.87 x 4 mm), when the new recommended safety margins are used, or until 1344.13 mm3 (32.47 x 7.87 x 5.26 mm), when considering the safety margins previously described. These values show the available bone of the mandibular symphysis as one of the main options for removal of the autogenous graft in partial maxillary reconstructions.
132

Influência da terapia fotodinâmica na manutenção da crista óssea alveolar periimplantar / Influence of photodynamic therapy in the maintenance of peri-implant bone crest

Franco, João Eduardo Miranda 02 July 2014 (has links)
A colonização bacteriana no sulco periimplantar ocorre muito precocemente, logo após a cirurgia de instalação dos implantes. Com este intuito, o projeto foi proposto a fim de avaliar o efeito da terapia fotodinâmica (PDT) na manutenção da crista óssea alveolar. Em um estudo de boca dividida, 20 pacientes foram reabilitados com implantes Standard Plus (Straumann®), divididos em dois grupos: um grupo controle (GC) e um grupo submetido à terapia fotodinâmica (GPDT), cujo protocolo foi: densidade de energia 120J/cm2, potência de 40mW, associada ao corante azul de metileno a 0,005%. As aplicações foram realizadas no dia da instalação do implante, após 15, 30 e 45 dias. As coletas microbiológicas foram efetuadas no período inicial e 6ª semana, nos dois grupos, utilizando cones de papel estéril. No GPDT, outras duas coletas foram realizadas após aplicação da terapia: no dia da cirurgia e após 45 dias. As unidades formadoras de colônias totais (UFCt) e pigmentadas de preto (UFCpig) foram contadas. Dados clínicos (Índice de Placa- IP e Sangramento a Sondagem- SS modificados por Mombelli) foram obtidos na 6a semana, 6 meses e 1 ano. Análise radiográfica, com radiografias periapicais, foram efetuadas utilizando a técnica da subtração radiográfica. As películas foram digitalizadas com o escaner SprintScan 35 Plus - Polaroid. Com softwares de manipulação de imagens (Adobe Photoshop CS2®- Califórnia, EUA e ImageJ- National Institutes of Health) foram medidas as distâncias do ombro do implante ao primeiro contato implante-osso, nas seguintes fases: inicial; 6a semana; instalação da prótese, 6 meses e 1 ano após instalação protética. Os testes estatísticos aplicados foram Friedman, Wilcoxon e MannWhitney. Quanto à eficiência da PDT, os resultados mostraram que houve uma redução, estatisticamente significante, tanto para UFCt como UFCpig nos dois momentos aplicados. O número de UFCt e UFCpig do pós-cirúrgico até a 6ª semana apresentou aumento, estatisticamente significante, nos dois grupos. No comparativo entre grupos não houve diferença, estatisticamente significante, entre a diferença do número de UFCt e UFCpig do período inicial ate a 6ª semana. O IP e SS foram similares entre os dois grupos. A avaliação radiográfica mostrou que houve uma perda da crista óssea crescente do período inicial até a instalação da prótese, que se manteve mantém estável após um ano de função para os dois grupos. A média da perda óssea, do período inicial até a instalação da prótese, foi de 0,73mm para o GC e de 0,84mm para o GPDT. Durante o período de função protética as médias de perda óssea foram, respectivamente, 0,27mm e 0,19mm para os GC e GPDT, sem diferença estatisticamente significante entre os grupos. Concluiu-se que: a PDT é eficiente para a redução das UFCt e UFCpig, presentes no sulco periimplantar, durante a osteointegração; a PDT não impede a recolonização, nem o crescimento bacteriano ao longo do tempo, exceto as UFCpig do GPDT, onde a quantidade de bactérias durante a osteointegração manteve-se estatisticamente estável; e com relação à manutenção da crista óssea periimplantar, os GC e GPDT tiveram resultados similares, sem diferença estatisticamente significante. / Bacterial colonization of the peri-implant sulcus occurs very early, right after the implant placement surgery. To this purpose, the project was proposed to evaluate the effect of photodynamic therapy (PDT) in the maintenance of {the} alveolar bone crest. In a split-mouth study, 20 patients were rehabilitated with Standard Plus implants (Straumann®) and they were divided into two groups: a control group (CG) and a group submitted to photodynamic therapy (GPDT), whose protocol was: energy density of 120J/cm2 at power of 40 mW, combined with 0,005% methylene blue. The applications were performed on the day of implant placement, after 15, 30 and 45 days. Microbiological samples were collected in the initial period and after 6 weeks on both groups, using sterile paper cones. In GPDT, two other collections were made after the application of the therapy: on the day of surgery and after 45 days. The total colony forming units (UFCt) and pigmented black units (UFCpig) were counted. Clinical data (Plaque Index-IP and Sulcus bleeding index- SS modified by Mombelli) were obtained at the 6th week, 6 months and 1 year. Radiographic analysis with periapical radiographs were made using the radiographic subtraction technique. The films were digitalized with the scanner SprintScan 35 Plus- Polaroid. Using image manipulation softwares (Adobe Photoshop® CS2- California and ImageJ-National Institutes of Health) distances from the implant shoulder to the first bone-implant contact were measured in phases: initial; 6th week; installation of the prosthesis, 6 months and 1 year after prosthetic installation placement. Friedman, Wilcoxon and Mann-Whitney were the statistical tests applied. Concerning the PDT efficacy, the results presented a statistically significant reduction for both UFCt and UFCpig in the two performed moments. The number of UFCt and UFCpig of the immediate postoperative to 6 weeks indicated a statistically significant increase in both groups. Comparing both the two groups, there was no statistically significant difference between the number of UFCt and UFCpig of the initial period to the 6th week. The IP and SS were similar in both groups. Radiographic evaluation indicated that there was an increasing loss of bone crest during the initial period and the installation of the prosthesis, which remained stable after a year of function for both groups. The bone loss average from the initial period until the installation of the prosthesis was 0,73mm for the GC and 0,84mm for the GPDT. During the prosthetic function the bone loss averages were, respectively, 0,27mm and 0,19mm for the GC and for the GPDT, with no statistically significant difference for both groups. The data led to the conclusion that: PDT is effective in reducing UFCt and UFCpig present in the peri-implant groove during the osseointegration; the PDT does not avoid the re-colonization or bacterial growth over time, except for the UFCpig of GPDT, wherein the amount of bacteria during the osseointegration remained statistically stable; and regarding to the maintenance of the peri-implant bone crest, the GC and GPDT obtained had similar results, with no statistically significant difference.
133

Sobrevida e perda marginal óssea de implantes de diâmetro estreito de liga titânio-zircônia e titânio puro / Survival rate of titanium-zirconium narrow diameter dental implants and commercially pure titanium narrow diameter dental implants

Iegami, Carolina Mayumi 15 August 2018 (has links)
Apesar da existência de diversos estudos que validem o uso de implantes de diâmetro estreito, a maioria é baseada em ligas de titânio puro. Há pouca evidência clínica em relação ao sucesso do implantes de diâmetro estreito de titânio-zircônia (TiZr NDIs), no que diz respeito à taxa de sobrevida (SR) e perda óssea marginal (MLB). O objetivo desta revisão sistemática foi analisar sistematicamente SR, assim como MBL de TiZr NDIs quando comparados a implantes de diâmetro estreito de titânio comercialmente puro (cpTi NDIs). A busca foi conduzida nas bases Medline/Pubmed, Cochrane, Scopus e Embase (do ano 2000 a novembro de 2016). Foram incluídos estudos clínicos do tipo coorte e randomizados. Dos 3453 artigos inicialmente identificados, foram incluídos seis estudos clínicos. Não houve diferença estatisticamente significante em taxa de sobrevida quando comparados os grupos TiZr NDIs e cpTi NDIs, em um ano de acompanhamento (p=0,5), além disso, também não houve diferença na comparação entre região de implantação (anterior ou posterior) no grupo TiZr NDIs. Não houve diferença entre os grupos anterior e posterior em relação à taxa de sobrevida em um ano: -0,01 (95% CI, -0,05 a 0,03) e perda óssea marginal: -0,01 mm (95% CI: -0,14 a 0,12). Pode-se concluir que TiZr NDIs apresentam taxas de sucesso e reabsorção óssea peri-implantar similares às de cpTi NDis. / Despite the existence of several studies validating the use of narrow diameter implants, most of them are based on pure Ti alloys. There is few clinical evidence of the success of TiZr narrow diameter implants (TiZr NDIs) regarding survival rate and marginal bone loss. The aim of this review was to systematically assess survival rate, as well as marginal bone loss of TiZr NDIs compared to commercially pure titanium narrow diameter implants (cpTi NDIs). Material and Methods: The search was conducted in Medline/PubMed, Cochrane, Scopus and Embase databases (year 2000 to November 2016). Cohort studies and randomized trials were included. Results: Six clinical studies from the 3453 articles initially identified met the inclusion criteria. There were no statistically significant differences in survival rate when TiZr NDIs and cpTi NDIs were compared in the 1-year follow up (p=0.5), or when comparing TiZr NDIs placed in posterior and anterior regions. There was no difference between groups regarding 1-year SR: -0.01 (95% CI, -0.05 to 0.03) and MLB: -0.01 mm (95% CI: -0.14 to 0.12). Conclusion: It can be concluded that TiZr NDIs present similar success rates and peri-implant bone resorption to cpTi NDIs.
134

Relação da distância interimplantar e altura do ponto de contato na formação de papilas gengivais: estudo em cães / Influence of interimplantar distance and height from the point of contact in the formation of gingival papilae: a study in dogs

Cruvinel, Diogo Rodrigues 24 April 2009 (has links)
Os implantes dentais são considerados uma modalidade de tratamento bastante previsível para a reposição de dentes perdidos. Os implantes osseointegráveis principalmente quando colocados em regiões anteriores devem oferecer, além de excelente função, ótima estética, e fonética. Sendo que o critério para o sucesso envolve o estabelecimento do contorno de tecido mole, apresentando a área interproximal intacta. O propósito deste estudo foi avaliar a influência das diferentes distâncias (3 e 5 mm) entre a crista óssea e ponto de contato interdental, na formação de papila gengival associado à presença de diferentes distâncias (2 e 3 mm) entre implantes contíguos e na região de extremo livre mesial e distal. Foram selecionados para o experimento 8 cães adultos jovens e executada a exodontia dos 4 pré-molares mandibulares: p1, p2, p3, p4, para cada hemi-mandibula. Três meses após as exodontias foram colocados 3 implantes Replace Select Tapered com superfície tratada e dimensões de 4,3 X 10 mm, em cada hemimandibula animal. O primeiro implante foi colocado a 10 mm da distal do canino remanescente, o segundo (intermediário) foi colocado a 2 mm do primeiro e o terceiro implante (posterior) foi colocado a 3 mm do segundo. Foi iniciada a reabilitação protética, no dia da colocação dos implantes. Primeiramente foi feita a moldagem para a confecção das próteses metálicas. As coroas metálicas definitivas, confeccionadas, apresentaram distância do ponto de contato à crista óssea de 3 e 5 mm lado esquerdo e direito respectivamente. Ao completar 12 semanas pós-colocação das próteses definitivas, os animais foram sedados e as análises clínicas foram executadas. Esta avaliação foi feita a partir da utilização de um compasso de pontas secas, medindo as distâncias entre os pontos de contato e as pontas das papilas (PC - P) e dos pontos de contato aos extremos livres mesial e distal (PC - ELM e PC ELD respectivamente). O delineamento das situações experimentais foi executado levando em consideração as associações das diferentes distâncias interimplantar com as diferentes distâncias do ponto de contanto a crista óssea, assim encontramos a seguinte disposição: Situação 01 (PC3A) Distância do ponto de contato a gengiva do extremo livre mesial, do lado esquerdo; Situação 02 (PC3B) Distância do ponto de contato, a gengiva interproximal sendo à distância interimplantar de 2 mm, lado esquerdo da mandíbula; Situação 03 (PC3C) Distância do ponto de contato, a gengiva interproximal sendo a distância interimplantar de 3 mm, lado esquerdo da mandíbula; Situação 04 (PC3D) Distância do ponto de contato a gengiva do extremo livre distal, do lado esquerdo Situação 05 (PC5A) Distância do ponto de contato a gengiva do extremo livre mesial, do lado direito; Situação 06 (PC5C) Distância do ponto de, a gengiva interproximal sendo a distância interimplantar de 3 mm, lado direito da mandíbula; Situação 07 (PC5B) Distância do ponto de contato, a gengiva interproximal sendo a distância interimplantar de 2 mm, lado direito da mandíbula e Situação 08 (PC5D) Distância do ponto de contato a gengiva do extremo livre distal, do lado direito. Ao analisar as medias das alturas gengivais temos: PC3A a média de 2,9±0,5 mm; PC3D 2,5±0,5 mm; PC3B 1,8±0,6 mm; PC3C 2,0±0,8 mm; PC5A 3,0±0,5 mm; PC5D 3,5±0,4 mm; PC5C 3,6±0,4 mm e PC5B 3,9±0,7 mm. Como as premissas de aderência à distribuição normal, independência entre os indivíduos estudados e pareamento entre as diferentes etapas foram cumpridas, empregou-se a análise de variância (ANOVA) para mensurações repetidas, a dois fatores. Nos casos em que a ANOVA encontrou diferença entre as situações testadas, uma comparação a posteriori foi executada por meio do teste de Bonferroni. O nível de significância empregado para todos os testes foi de 0,05 (5%). Logo as distâncias de 2,0 e 3,0 mm entre implantes contíguos não apresentaram diferença significativa na formação de papila quando as restaurações protéticas são confeccionadas com 3 ou 5 mm de distância entre o ponto de contato e a crista óssea. Considerando a provável reabsorção óssea em ambos os grupos, quando a distância do ponto de contato à crista óssea foi inicialmente de 3 mm esta condição apresentou melhores resultados na formação de papilas do que a distância de 5 mm em todas as situações estudadas. A presença do ponto de contato de 3 mm influência positivamente na formação de papila, quando comparada com as regiões de extremo livre. / The dental implants are considered a form of treatment rather predictable for replacement of lost teeth Implants should offer, as well as excellent function, aesthetics and phonetics great, especially when placed in anterior regions, where the criterion for success involves the establishment contour of the soft tissue, showing the area intact interproximal The purpose of this study was to evaluate the influence of different distances between the bone crest and interdentally contact point, with 3 and 5 mm, the formation of gingival papilla associated with the presence of different distances of 2 and 3 mm between implants and the adjacent region of mesial and distal end free. Were selected for the experiment 08 dogs and young adults performed the extraction of the 4 pre molars mandibles: p1, p2, p3, p4, for each hemi-mandible. Three months after the tooth extractions were placed 3 Replace Select Tapered implants with treated surface and dimensions of 4.3 X 10 mm in each animal hemi mandibles. The first implant was placed at 10 mm distal of the canine left, the second (middle) was placed at 2 mm from the first and third implant (back) was placed at 3 mm from the second. Prosthetics rehabilitation has begun on the day of the placement of implants. First was the casting for the manufacture of metal stents, since the provisional prostheses were made of acrylic resin so that the distance between the point of contact and the bone crest is 3 mm on the left side of the mandible and 5 mm on the right. The final metal crowns, made, made from the point of contact to bone crest of 3 and 5 mm. After completing 12 weeks after placement of final prosthesis, the animals were sedated and the clinical tests were performed. This evaluation was made from the use of a dry bar for tips, measuring the distances between the points of contact and the tips of the papillae (PC - P) and the contact points of the mesial and distal ends free (PC - PC and ELM - ELD respectively). The design of the experimental situations was implemented taking into account the associations of different distances interimplantar with different distances from the long bone crest, we found the following provision: Location - 01 (PC3A) Distance from the point of contact to end the free gingiva mesial to the left; Situation - 02 (PC3B) Distance from the point of contact, the gingival interproximal distance being interimplantar of 2 mm, the left side of the mandible; Situation - 03 (PC3C) Distance from the point of contact, the gingival interproximal and interimplantar a distance of 3 mm, the left side of the mandible; Situation - 04 (PC3D) Distance from the point of contact to the extreme free gingival distal to the left position - 05 (PC5A) Distance from the point of contact to the extreme free gingival mesial on the right side; Situation - 06 (PC5C) distance from the interproximal gingival interimplantar the distance of 3 mm, right side of the jaw; Situation - 07 (PC5B) Distance from the point of contact, the gingival interproximal the distance interimplantar of 2 mm, the right side of the mandible and Situation - 08 (PC5D) Distance from the point of contact to free distal end of the gingival on the right side. In examining the measures of gingival heights are: PC3A an average of 2.9 ± 0.5 mm; PC3D 2.5 ± 0.5 mm; PC3B 1.8 ± 0.6 mm; PC3C 2.0 ± 0.8 mm; PC5A 3.0 ± 0.5 mm; PC5D 3.5 ± 0.4 mm; PC5C 3.6 ± 0.4 mm and PC5B 3.9 ± 0.7 mm. As adherence to the assumptions of normal distribution, independence among the subjects studied and matching between the different stages have been completed, using the analysis of variance (ANOVA) for repeated measurements, the two factors. Where ANOVA found the difference between the conditions tested, a posteriori comparison was performed using the Bonferroni test. The significance level used for all tests was 0.05 (5%). Once the distances of 2.0 and 3.0 mm between adjacent implants showed no significant difference in the formation of the papilla when prosthetic restorations are made with 3 or 5 mm distance between the point of contact and the bone crest. Considering the probable bone resorption in both groups, where the distance from the point of contact to the bone crest was originally the condition of 3 mm showed better results in the formation of papillae than the distance of 5 mm in all cases studied. The presence of the point of contact 3-mm positively influence the formation of papilla, when compared with regions of extreme freedom.
135

Análise da distribuição das tensões em restaurações cerâmicas sobre dente natural e implante por meio do método dos elementos finitos /

Freitas Júnior, Amilcar Chagas. January 2008 (has links)
Resumo: As restaurações cerâmicas têm proporcionado resultados satisfatórios estética e biomecanicamente. Porém, a comparação dos dados sobre a distribuição das tensões nos casos de diferentes restaurações suportadas por dente ou por implante é inconclusiva. O objetivo desse estudo foi avaliar, através da análise de elementos finitos bidimensional, a distribuição interna das tensões nos materiais e estruturas de suporte em função de duas possibilidades restauradoras em cerâmica (faceta laminada e coroa total) e dois tipos de suportes (dente natural e implante). Foram confeccionados 8 (oito) modelos (M) no programa AutoCad 2006, variando o tipo de suporte e restauração: MA (controle) - representação do incisivo central maxilar, hígido, seccionado sagitalmente; MB1, MB2 e MB3 - semelhantes ao MA, restaurados com faceta laminada pelo sistema IPS Empress, IPS Empress Esthetic e Laminado Procera, respectivamente; MC1 e MC2 - semelhantes ao MA, com coroa total pelo sistema IPS Empress 2 (MC1) e Procera AllCeram (MC2); MD1 e MD2 - porção coronária semelhante ao MC1 e MC2, respectivamente, com a presença de um implante osseointegrado (Sistema Bränemark - 4,3 X 15,0 mm) e pilar em zircônia. Para análise numérica (Ansys 10.0), os modelos foram carregados (C) sob duas condições (50N): C1 - 45º de inclinação com o longo eixo dental, no terço médio da face palatina; C2 - perpendicular à borda incisal. Adicionalmente, uma terceira condição foi adotada para o MA: C3 - 50N na borda incisal paralelo ao longo eixo dental. Foram obtidas a tensão equivalente de von Mises (σvM) e a máxima tensão principal em tensão (σmax.t) e compressão (σmax.c). Observou-se que C3 proporcionou a menor variação de svM no dente e estruturas de suporte quando comparada à C1 e C2. / Abstract: The ceramics restorations have provided excellent aesthetic and biomechanical clinical results. However, the data about the stress distribution in tooth and implant-supported restorations are inconclusive. Using two-dimensional finite element analysis, the purpose of this study was to evaluate the stress distribution in the materials and support structures based on two ceramics restorative possibilities (laminate veneer and ceramic crown) and two support structures (tooth and implant). 8 models (M) were built in the program AutoCAD 2006, varying the restorations and their support structures: MA (control) - an intact maxillary central incisor in sagittal cut; MB1, MB2 and MB3 - similar to MA, with laminate veneers of IPS Empress, IPS Empress Esthetic and Procera veneer, respectively; MC1 and MC2 - similar to MA, with a full crown of IPS Empress 2 (MC1) and Procera AllCeram (MC2); MD1 and MD2 - coronary portion similar to MC, with an osseointegrated implant (Bränemark System - 4.3 X 15.0 mm) and zircon abutment. To the numerical analysis (Ansys 10.0), the following loadings (L) were performed (50N): L1 - on the medium third of the lingual face, in 45º with the dental long axis; L2 - perpendicular to the incisal edge; L3 - 50N in the incisal edge parallel to the tooth long axis (only for the natural tooth). The von Mises equivalent stress (σvM) and maximum principal stress in tension (σmax.t) and compression (σmax.c) were obtained. It was observed that L3 provided the smallest variation of σvM in the tooth and support structures in comparison with L1 and L2. The beam3 elements used for the periodontal ligament modeling showed an appropriate behavior for parallel loading. In the MB and MC, the ceramics increased the σvM in the adhesive interface, mainly for Procera. In the models with implant, the IPS Empress2 showed higher σvM than that for Procera AllCeram. / Orientador: Eduardo Passos Rocha / Coorientador: Paulo Henrique dos Santos / Banca: Altair Antoninha Del Bel Cury / Banca: Wirley Gonçalves Assunção / Mestre
136

Avaliação do aquecimento ósseo, da viabilidade celular imediata e da deformação de fresas de alta resistência após osteotomia para implantes em tíbias de coelhos /

Carvalho, Abrahão Cavalcante Gomes de Souza. January 2008 (has links)
Resumo: O propósito deste trabalho foi avaliar a influência da reutilização de fresas de alta resistência sobre o aquecimento ósseo, a viabilidade celular imediata e a deformação das fresas após osteotomia para implantes em tíbias de coelhos. Para isso, foram utilizados 12 coelhos machos brancos (Oryctolagus cunilicus, Nova Zelândia), que foram submetidos a 200 sequências de fresagens para implantes na cortical superior de suas tíbias. Foram estabelecidos 6 grupos (G1 a G6) que correspondiam ao número de osteotomias realizadas por cada fresa (0, 10, 20, 30, 40 e 50). Cada leito cirúrgico recebia a seguinte sequência de fresagem: fresa tipo lança e helicoidais de 2,0mm, 2,8mm, 3,0mm e 3.15mm. As áreas osteotomizadas foram coletadas para análise imunoistoquímica, as oscilações térmicas foram quantificadas e as fresas utilizadas receberam análise por microscopia eletrônica de varredura. Nos resultados, houve uma correlação alta entre a porcentagem de deformação e o número de reutilização de cada fresa (Coeficiente de Correlação de Pearson r = 0,984). Observou-se também que as fresas do tipo lança apresentaram maior deformação após o uso do que as fresas helicoidais (proporção de 2:1). Não houve correlação estatística significativa entre aumento da reutilização da fresa e aquecimento ósseo (p > 0,05). No entanto, observouse que a oscilação térmica durante a fresagem da lança é maior que as demais fresagens (proporção de 3:1). Na análise imunoistoquímica, observou-se um equilíbrio fisiológico da expressão das proteínas Osteoprotegerina e RANKL em todos os grupos, no entanto, houve maior expressão de todas as proteínas no Grupo 6. De acordo com a metodologia aplicada, foi possível concluir que as fresas avaliadas não causam aquecimento ósseo significativo em até 50 reutilizações, no entanto, causam maior trauma tecidual na 50ª fresagem... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was evaluate the influence of high resistence drill reuse over bone heating, immediate bone-cell viability and drills wear after implant osteotomies in rabbit tibias. Therefore, 12 male white rabbits (Oryctolagus cunilicus, New Zealand) received 200 implant sequential osteotomies over the superior cortical of their tibia. Six groups were established (G1 to G6), according to the number of osteotomy of each drill (0, 10, 20, 30, 40 and 50). The implant sequence of drills was: spear drill, 2,0mm, 2.8mm, 3.0mm and 3.15mm helicoidal drills. The receptor-beds were collected to imunohistochemistry, the thermal changes were quantified and the drills received scanning electron microscopy analysis. In the results, a great correlation degree between drill wear and number of osteotomies was observed (Pearson's Correlation Coefficient r = 0,984). Another result was that spear drill have more deformation than helicoidal drills (2:1 proportion). The bone heating analysis concluded that there was no statistical siginificance between number of osteotomy and bone heating (p > 0,05). However, the thermal changes during spear drilling was greater than during helicoidal drillings (3:1 proportion). Imunohistochemistry results showed a physiological balance of Osteoprotegerin and RANKL immunolabeling in all groups, however there was a greater immunolabeling of all proteins in the last group. According to this metodology, the conclusion is that the tested drills do not caused significant bone heating after 50 reuses, however, they caused more tissue trauma at 50th osteotomy. So, the studied system must be reused for 40 times, and the spier drill must be substituted after 20 osteotomies. / Orientador: Luiz Antonio Salata / Coorientador: Osvaldo Magro Filho / Banca: Márcio de Moraes / Banca: Idelmo Rangel Garcia Júnior / Mestre
137

Distribuição de tensões geradas por próteses esplintadas ou individualizadas sobre implantes com reabilitações em diferentes rebordos. Análise pelo método dos elementos finitos / Stress distribution generated by splinted or individualized implant prostheses with rehabilitation in different edges. A finite element analysis

Toniollo, Marcelo Bighetti 28 August 2014 (has links)
O emprego dos implantes ósseointegráveis na odontologia moderna tem conquistado destaque nas reabilitações de forma crescente. Em casos de perda óssea vertical severa, a qual se faz bastante presente em áreas posteriores mandibulares, o uso de implantes curtos e de diâmetro reduzido se faz necessário. Para que a reabilitação mantenha o plano oclusal nivelado, utiliza-se próteses sobre implantes com proporção coroa/implante aumentada, sendo importante avaliar se há sobrecarga das estruturas de suporte, e se convém a esplintagem da infraestrutura reabilitadora. Um dos métodos utilizados atualmente para análise de distribuição de tensões na odontologia é o método dos elementos finitos. Assim, este estudo teve o objetivo geral de comparar o desempenho biomecânico de próteses, esplintadas (PSIE) ou individualizadas (PSII), sobre implantes cone Morse de comprimento regular e curto, em área posterior de mandíbula. Foram usados modelos geométricos tridimensionais de implantes regulares ∅ 4x11 mm e curtos - ∅ 4x5 mm alojados em rebordos representativos do hemi-arco mandibular esquerdo posterior envolvendo o dente 34 adjacente ao espaço anodôntico, desenhados no programa SolidWorks 2007. Os 8 grupos experimentais foram: grupo controle E (3 implantes regulares reabilitados com PSIE), grupo 1E (2 implantes regulares e 1 curto reabilitados com PSIE), grupo 2E (1 implante regular e 2 curtos reabilitados com PSIE) e grupo 3E (3 implantes curtos reabilitados com PSIE); grupo controle I (3 implantes regulares reabilitados com PSII), grupo 1I (2 implantes regulares e 1 curto reabilitados com PSII), grupo 2I (1 implante regular e 2 curtos reabilitados com PSII) e grupo 3I (3 implantes curtos reabilitados com PSII); As alturas dos pilares usados foram 3,5 mm para implantes regulares e 0,8 mm para implantes curtos. Foram simuladas forças oblíquas (45° - linguo-vestibular) de 365N em molares e 200N em prémolares. Análises qualitativas e quantitativas da distribuição de tensões máximas e mínimas principais (ossos cortical e esponjoso) e tensão equivalente de von Mises (implantes, componentes e infraestruturas) foram feitas por meio do programa AnsysWorkbench10.0. Os resultados obtidos permitiram concluir que o uso de PSIE propiciou uma série de vantagens e benefícios com relação à distribuição de tensões nos elementos envolvidos no sistema, sendo benéfica a todos os grupos experimentais do presente estudo, notoriamente ao grupo com presença apenas de implantes curtos, diminuindo as tensões no osso circunjacente aos implantes, principalmente em sua abrangência. Também diminuiu as tensões na superfície dos implantes, na área de transmucoso dos pilares/componentes, na região interna das infraestruturas e sua abrangência ao osso circunjacente aos implantes curtos nos grupos com implantes regulares e curtos. No entanto, nesse mesmo contexto, gerou maior tensão ao osso circunjacente aos implantes regulares intermediários comparativamente aos grupos individualizados. Também favoreceu a diminuição das tensões ao osso circunjacente ao dente adjacente, quando na presença de proporção coroa/implante aumentada. O uso PSII apresentou-se vantajosa na diminuição das tensões na parte superior dos pilares e na área de conexão entre coroas, além do grupo controle, apenas com implantes regulares e próteses de proporção normal, sendo viável sua utilização neste contexto frente às vantagens clínicas não oferecidas pelas próteses esplintadas. / The use of dental implants in modern dentistry has gained prominence in oral rehabilitations. In cases of severe vertical bone loss, which is very much present in mandibular posterior areas, the use of short implants and reduced diameter is necessary. To maintain the occlusal plane level rehabilitation it is necessary the use of prostheses with increased crown/implant ratio , and it is important assess whether there is overhead of supporting structures, and befits splinting the rehabilitating infrastructure. One of the methods currently used to analyze the stress distribution in dentistry is the finite element method. Thus , this study has the overall objective to compare the biomechanical performance of prostheses, splinted (PSIE) or individualized (PSII) over Morse taper implants of regular and short length in the posterior area of the mandible. It were used three-dimensional geometric models of regular implants - ∅ 4x11 mm and short implants - ∅ 4x5 mm housed in representative edges of the posterior left mandibular hemi-arch tooth involving 34 teeth, designed in SolidWorks 2007 program. The 8 experimental groups were: control group E (3 regular implants rehabilitated with PSIE ), group 1E (2 regular and 1 short implants rehabilitated with PSIE) , 2E group (1 regular implant and 2 short implants rehabilitated with PSIE) and 3E group (3 short implants rehabilitated with PSIE); control group I (3 regular implants rehabilitated with PSII), group 1I (2 regular and 1 short implants rehabilitated with PSII), 2I group (1 regular implant and 2 short implants rehabilitated with PSII) and 3I Group (3 short implants rehabilitated with PSII); The pillars heights used for regular implants were of 3.5 mm and 0.8 mm for the short implants. Oblique forces (45° linguo-vestibular) were simulated in molars (365N) and premolars (200N). Qualitative and quantitative analysis of the distribution of maximum and minimum principal stresses (cortical and cancellous bone) and von Mises equivalent stress (implants, components and infrastructure) were made through the software AnsysWorkbench10.0. The results showed that the use of PSIE provided advantages and benefits regarding the stresses distribution in the elements involved in the system, being beneficial to all experimental groups of this study notoriously in the group with only short implants, reducing stresses in the surrounding bone to implants, especially in coverage. Also decreased the stresses on the implants surface, in the transmucosal abutments area, in the inner region of the infrastructure and its reach to the surrounding bone to short implants in groups with regular and short implants. However, in that respect, generated higher stresses to the surrounding bone of intermediate implants compared to the individualized groups. Also favoring a decrease of the stresses to surrounding bone adjacent to the tooth, in the presence of increased crown/implant ratio. The use PSII showed to be advantageous in reducing stresses on top of the abutments and the area of connection between crowns, and in the control group, only with regular implants and prostheses of normal crown/implant ratio, so it can be used in this context facing the clinical advantages not offered by splinted prostheses.
138

Avaliação da influência do diâmetro e comprimento do implante osseointegrado associado à PPR Classe I mandibular pelo método dos elementos finitos /

Verri, Fellippo Ramos. January 2003 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Dalva Cruz Laganá / Banca: Eduardo Passos Rocha / Resumo: A influência do diâmetro e do comprimento de implantes osseointegrados em associação com próteses parciais removíveis de extremidade livre (PPRELs) ainda não foi relatada na literatura. Dessa forma, este trabalho visou avaliar a esta influência, utilizando o método dos elementos finitos (MEF) bi-dimensional, associando implantes osseointegrados do sistema Branemark sob a base protética de uma PPREL, funcionando apenas como suporte, e analisando mapas de deslocamento e de tensão de von Mises. Para o estudo foram confeccionados oito modelos representativos de uma hemi-arcada mandibular com a presença apenas dos dentes 33 e 34, com as seguintes características: A - sem PPR; B - com PPR sem implante; C - com PPR e implante de 3,75 x 7,00 mm; D - com PPR e implante de 3,75 x 10,00 mm; E - com PPR e implante de 3,75 x 13,00 mm; F - com PPR e implante de 5,00 x 7,00 mm; G - com PPR e implante de 5,00 x 10,00 mm; H - com PPR e implante de 5,00 x 13,00 mm. As forças aplicadas foram estritamente verticais e de 50 N em cada ponta de cúspide. Pelos resultados notou-se que a presença da PPR sobrecarregou o dente suporte, bem como as demais estruturas de suporte da PPR quando comparadas com o modelo A. A presença do implante diminuiu as tensões, principalmente nas extremidades do rebordo desdentado, quando comparados o modelo B com os modelos que possuíam implantes associados. Tanto o comprimento quanto o diâmetro do implante tenderam a diminuir as tensões à medida que aumentavam suas dimensões. Pelos resultados foi possível concluir que: o modelo B foi o que apresentou a maior tendência a deslocamento; quanto maior o comprimento do implante, menores foram os valores do mapa de deslocamento; o modelo B apresentou níveis de tensão de von Mises superiores ao modelo A; os modelos com implantes associados apresentaram níveis menores de tensão de von Mises que o modelo B nas estruturas de suporte da PPR. / Abstract: The influence of the diameter and length of osseointegrated implants in association with removable partial prostheses of distal-extension (DERPDs) it was not still reported in the literature. In that way, this study evaluated this influence, associating osseointegrated implants of the Branemark system under the prosthetic base of a DERPD, just working as support, and analyzing displacement and von Mises tension maps, using bi-dimensional finite element analysis (FEA). For this study, eight representative models of a lower hemi-arcade were made with the presence of only the teeth 33 and 34, with the following characteristics: A - without RPD; B - with RPD and without implants; C - with RPD and implant of 3,75 x 7,00 mm; D - with RPD and implant of 3,75 x 10,00 mm; E - with RPD and implant of 3,75 x 13,00 mm; F - with RPD and implant of 5,00 x 7,00 mm; G - with RPD and implant of 5,00 x 10,00 mm; H - with RPD and implant of 5,00 x 13,00 mm. The applied forces were strictly vertical and of 50 N in each edge tip. The results shown that the presence of RPD overloaded the support tooth, as well as the other structures of support of RPD when compared with the model A. The presence of the implants reduced the tensions, mainly in the extremities of the toothless edge, when compared model B with the models that possessed implant associated. So much the length as the diameter of the implants tended to reduce the tensions as increased your dimensions. For the results it was possible to conclude that: the model B was what presented the largest tendency to displacement; as larger the length of the it implants, smaller they were the values of the displacement map; the model B presented levels of von Mises tension superiors to the model A; the models with implant associated presented smaller levels of von Mises tension that the model B in the structures of support of RPD; the increase of the length and of the diameter of the implants. / Mestre
139

Efeito da ausência de passividade no sistema coroa-implante-parafuso de retenção por meio do MEF-2D /

Gomes, Érica Alves. January 2006 (has links)
Orientador: Wirley Gonçalves Assunção / Banca: Paulo Henrique dos Santos / Banca: Flávio Domingues das Neves / Resumo: Objetivo: avaliar o deslocamento e distribuição interna de tensões do sistema coroa/implante/parafuso de retenção e tecido ósseo adjacente, em função de diferentes níveis de desadaptação angular unilateral, por meio do MEF-2D. Materiais e método: foram confeccionados 4 modelos matemáticos, representativos de coroa metálica conectada a implante por meio de parafuso deretenção, inseridos em tecido ósseo, determinando os 4 grupos estudados: Grupo 1 (controle), coroa completamente adaptada ao implante; Grupo 2, 3 e 4, coroa com desadaptações angulares unilaterais de 50æm, 100æm e 200æm, respectivamente. A partir do programa de elementos finitos Ansys, os modelos receberam carga de 133N, com angulação de 30o e deslocamento de 2mm do longo eixo do implante em lado oposto a desadaptação, sendo analisados os mapas de tensões e deslocamento. Resultados: com o aumento das desadaptações angulares, os mapas de tensões mostraram aumento gradativo das tensões na coroa (1056 N/mm2 a 2326N/mm2) e no parafuso de retenção (909.91 N/mm2 a 987.02N/mm2) e uniformidade na distribuição de tensões no implante e tecido ósseo medular. Quanto ao deslocamento, verificou-se inclinação do conjunto de 0.3101mm (controle) a 0.3179mm no grupo 4, em função do carregamento e das desadaptações. Conclusão: a redução do contato unilateral entre a coroa e o implante levou ao deslocamento de todo conjunto e alteração na distribuição e magnitude das tensões ao longo do sistema, principalmente na região da coroa e parafuso de retenção, sendo que, de modo geral, as desadaptações angulares unilaterais de 100æm e 200æm mostraram maiores valores de tensões em relação ao controle. / Abstract: Objectives: the aim of this study was to evaluate the displacement and stress inner distribution of the prostheses/implant/abutment screw set and surrounding bone, with prostheses presenting different levels of angular misfit unilateral through FEA-2D. Materials and methods: four mathematic models were made, representing metal prostheses in connection of the implant through abutment screw, inside bone tissue, determining 4 groups: Group 1 (control) prostheses fit on the implant; Groups 2, 3 and 4, prostheses with angular misfit unilateral of 50æm, 100æm and 200æm, respectively. It was applied a load of 133N with 30o angulation and off-axis at 2mm of long axis of the implant in opposite direction of misfit on the models, through finite element program Ansys. Results: with upper of angular misfit, the stress maps showed gradual increased of prostheses stress (1056N/mm2 at 2326N/mm2) and uniform stress distribution in the implant and trabecular bone. About the displacement, observed inclination of the set of 0.3101mm (control) at 0.3179mm in the group 4 due to loading and misfit. Conclusions: the lower of the unilateral contact between prostheses and implant proportionate the displacement of all set and the distribution and magnitude alterations of the stress of all the system, principally in the prostheses and abutment screw regions; as a general rule, the angular misfit unilateral of the 100æm and 200æm showed higher stress values in relation to the control. / Mestre
140

Oligodontia and ectodermal dysplasia on signs, symptoms, genetics and outcomes of dental treatment /

Bergendal, Birgitta, January 2010 (has links)
Diss. (sammanfattning) Umeå : Umeå universitet, 2010. / Härtill 4 uppsatser.

Page generated in 0.187 seconds