• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • Tagged with
  • 27
  • 27
  • 27
  • 26
  • 26
  • 10
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo do conteúdo de partículas inorgânicas, da contração de polimerização e da resistência à flexão de materiais restauradores estéticos diretos indicados para dentes posteriores /

Adabo, Gelson Luis. January 2000 (has links)
Resumo: Recentemente, foram lançados no mercado odontológico novos materiais estéticos para restaurações diretas em dentes posteriores, aos quais são atribuídas propriedades mais adequadas para essa indicação. Entretanto, as informações disponíveis são ainda muito escassas, gerando dúvidas quanto à sua real eficácia, sobre quais as diferenças de suas composições e propriedades físicas e mecânicas em relação aos materiais até então disponíveis e se, de fato, apresentam melhor performance clínica. Em vista do exposto, nos propusemos a estudar contração de polimerização, resistência à flexão e concentração de partículas inorgânicas, por massa e volume, de sete resinas compostas (Alert, Ariston, Solitaire, Definite, Filtek P60, Z-100 e Tetric Ceram). A contração de polimerização foi medida nos materiais inseridos em um anel plástico, e o registro das alterações, durante a polimerização, foi feito por meio de instrumento eletrônico de medida linear, que registra as alterações dimensionais, com sensibilidade de 1 mm. A resistência à flexão foi medida na máquina de ensaios mecânicos MTS 810 e a confecção dos corpos-de-prova e dos dispositivos para o ensaio foi orientada pela norma ISO no 4049:1988. A determinação do conteúdo de partículas inorgânicas por massa foi feita através da pesagem de uma porção de resina composta polimerizada antes e após a eliminação da fase orgânica em forno, à temperatura de 700oC. O porcentual volumétrico de partículas inorgânicas foi calculado com base no Princípio de Arquimedes. Foi determinado o volume da resina composta polimerizada, antes e após a eliminação da fase orgânica, pela diferença da massa do material pesado ao ar e imerso em água. Os dados de conteúdo de partículas inorgânicas por massa e por volume, de contração de polimerização e resistência à flexão foram submetidos...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Recently new esthetic materials for direct restorations in posterior teeth were introduced in the dentistry market, which were attributed properties more adequate for this indication. However, the information avaiable is still very scarce, producing uncertainty of its real efficacy. There is existence of doubts regarding the differences in composition, physical and mechanical properties related to the materials available and if, in fact, they present better clinical performance. Due to the exposed, we proposed to study the polymerization contraction, flexural resistance and concentration of inorganic particles by mass and volume of seven composite resins (Alert, Ariston, Solitaire, Definite, Filtek P60, Z-100 and Tetric Ceram). The polymerization contraction was measured with the materials inserted in a plastic ring. The registration of the alterations, during the polymerization was done through an electronic instrument of linear dimension with sensibiligy of 1um. The flexural resistance was measured by the MTS 810 mechanical test machine and the confection of the samples and the device for the tests were orientated by the ISO nº 4049:1998 norm. The determination of the content of inorganic particles per mass was made. A portion of composite resin was weighed before and after the elimination of the organic phase in an oven, at a temperature of 700ºC. The volume percentage of the inorganic particles was calculated based on the Arquimedes's Principle. The volume of ocmposite resin polymerized was determined before and after the elimination of the organic phase, by the difference in the mass of the material weighed in air and immersed in water. The data regarding the content of inorganic particles per mass and volume, polymerization contraction and flexural resistance...(Complete abstract click electronic access below)
12

Resposta dos tecidos periodontais frente ao recobrimento de cavidades radiculares restauradas por materiais resinosos : estudo histomorfométrico em cães /

Martins, Thiago Marchi. January 2005 (has links)
Orientador: Álvaro Francisco Bosco / Banca: Adriana Campos Passanezi Sant'Anna / Banca: Valdir Gouveia Garcia / Resumo: O objetivo do trabalho foi avaliar histomorfometricamente em cães a resposta dos tecidos periodontais frente ao recobrimento de cavidades radiculares classe V restauradas ou não com materiais resinosos. Após levantamento de retalho mucoperiostal, defeitos ósseos de 5 x 5 mm foram criados na face vestibular de 15 caninos de 4 cães, seguidos de preparos cavitários de 3 x 3 x 1 mm na superfície radicular. Antes do reposicionamento do retalho para sua posição original com o objetivo de recobrir o defeito ósseo, as cavidades do grupo teste foram restauradas com resina composta micro-híbrida (RC) ou cimento de ionômero de vidro modificado por resina (RMGIC) e as do grupo controle (CO) permaneceram sem restauração. O sacrifício dos animais foi realizado aos 90 dias pós-operatórios. Foram obtidos cortes histológicos seriados vestíbulo-linguais, corados com HE e Tricrômico de Masson. As secções mais centrais foram selecionadas para a análise histomorfométrica. As medidas histológicas foram submetidas à análise estatística por meio dos testes: teste exato de Fisher, teste de Friedman, ANOVA e teste de Kruskal Wallis, considerando o nível de significância de 5%. Histologicamente observou-se migração apical do tecido epitelial (TE) sobre os materiais restauradores (RMGIC e RC). O grupo CO apresentou inserção conjuntiva (IC) significativamente maior (p<0.05) em relação aos grupos testes RMGIC e RC e regeneração óssea significativamente maior (p<0.05) em relação ao grupo teste RMGIC. Em todos os grupos observou-se histologicamente um infiltrado inflamatório crônico mais pronunciado no terço cervical (TC). Os resultados deste estudo permitiram concluir que os materiais restauradores resinosos empregados mostraram-se biocompatíveis, podendo ser uma alternativa na restauração de abrasões cervicais e/ou cáries profundas previamente ao procedimento cirúrgico de recobrimento radicular. / Abstract: This study analyzed the periodontal tissue response to coverage of root cavities filled with resin materials in dogs by histomorphometric evaluation. A mucoperiosteal flap was raised on 15 canines teeth of 4 dogs and bone defects measuring 5x5mm were created on the buccal aspect of canines, followed by cavity preparations measuring 3x3x1mm on the root surface. Before repositioning of the flap in its original position to cover the bone defect, the cavities of the study group were filled with microhybrid composite resin (CR) or resin-modified glass ionomer cement (RMGIC), and the control group (CO) was not filled. The animals were sacrificed at 90 days postoperatively. Serial buccolingual histological sections were achieved and stained with HE and Masson trichrome. The most central sections were analyzed for histomorphometric analysis. The histological measurements were submitted to statistical analysis by the Fisher's exact test, Friedman test, ANOVA and Kruskal Wallis test, at a significance level of 5%. Histological analysis revealed apical migration of the epithelial tissue (ET) over the restorative materials (RMGIC and CR). Group CO presented significantly larger (p<0.05) connective tissue attachment (CTA) than study groups RMGIC and CR, and significantly larger bone regeneration (p<0.05) compared to the study group RMGIC. All groups revealed chronic inflammatory infiltrate, more remarkably at the cervical third (CT). The results of this study allowed the conclusion that resin restorative materials employed were biocompatible and may be an option for restoration of cervical abrasions and/or deep caries before surgical procedure for root coverage. / Mestre
13

Influência de dois tipos de retentores intra-radiculares e do tipo de coroa total na resistência e modo de fratura de raízes de incisivos superiores /

Zamboni, Sandra Regina Oliveira Costa. January 2010 (has links)
Orientador: Lafayette Nogueira Junior / Banca: Eduardo Shigueiuki Uemura / Banca: Mário Alexandre Coelho Sinhoreti / Banca: Mauro Antonio de Arruda Nóbilo / Banca: Tarcísio José de Arruda Paes Junior / Resumo: O objetivo neste estudo foi avaliar e comparar a resistência à fratura de incisivos centrais restaurados usando dois tipos de pinos intra-radiculares: núcleo metálico fundido e pinos de fibra de quartzo, reconstruídos com diferentes tipos de coroas. A hipótese nula testada foi que a resistência a fratura desses corpos de prova não apresentariam diferença quanto ao tipo de pino e tipo de coroa. Sessenta incisivos centrais superiores foram divididos em 6 grupos: G1- núcleo metálico fundido + coroa em cerômero, G2- núcleo metálico fundido + coroa metalo-cerâmica, G3- núcleo metálico fundido + coroa em e-max, G4 - pino de fibra de quartzo e pinos acessórios + coroa em cerômero, G5- pino de fibra de quartzo e pinos acessórios + coroa metalo-cerâmica e G6- pino de fibra de quartzo e pinos acessórios + coroa em e-max. Todos os espécimes foram submetidos à ciclagem mecânica com freqüência de 2 Hz e 500.000 ciclos com carga de 3Kg. Os corpos de prova foram submetidos a teste de compressão em uma máquina universal de ensaios (Emic) com velocidade de carga de 1,0 mm/min até a sua fratura. Os valores de resistência à fratura foram G1- 47.44 ± 10.39, G2- 54.74 ±7.76, G3-49.71 ± 8.66, G4- 54.97 ± 8.67, G5-73.50 ± 11.83 e G6- 55.47 ± 10.62. A análise de variância (ANOVA) (p<0,05) mostrou diferença estatisticamente significante para os pinos. Quanto à análise de fratura, os núcleos metálicos fundidos apresentaram o maior número de amostras com fratura desfavoráveis quando comparados os pinos de fibra de quartzo. O conjunto pino de fibra restaurados com coroa metalo cerâmica, apresentou valor de resistência à fratura estatisticamente maior quando comparado aos demais grupos segundo o teste de Tukey (5%), Metalo cerâmica - 64,12±13,69 kgf, difere estatisticamente das demais coroas metal free - 52,59±9,88 kgf e cerômero - 51,20±10,08 kgf que... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to compare the fracture resistance and failure of maxillary incisors restored using fiber post and metallic post under different types of full-coverage crowns. The null hypothesis tested was that fracture resistance and the failure pattern of these teeth were not affected by the use of fiber post, metallic post and typo of full coverage crown. Sixty maxillary incisors were divided into 6 groups of 10 each. G1- metallic post + metallic ceramic crowns, G2- metallic post + e-max system, G3- metallic post + cerômeros, G4- Fiber post and accessories post + metallic ceramic crowns, G5- Fiber post and accessories post + e-max system and G6- Fiber post and accessories post + cerômeros. The specimens were submitted a mechanical loading at a frequency of 2 Hz for a total of 500.000 cycles. After were taken to the Universal Test Machine for the fracture resistance at 1,0 mm/min speed. The fracture resistance values were G1- 47.44 ± 10.39, G2- 54.74 ±7.76, G3-49.71 ± 8.66, G4- 54.97 ± 8.67, G5-73.50 ± 11.83 e G6- 55.47 ± 10.62. Results show statistically significant differences in relation to the type of the posts (ANOVA) (p<0,05). Fracture analyses about metallic post showed the most unfavorable fracture and fiber post restored with metallic crown showed statistically significant difference in relation to the others groups. Tukey test (5%) showed Metallic-crown - 64,12±13,69 kgf, is statistically difference than the other crowns metal free - 52,59±9,88 kgf and Sinfony crowns - 51,20±10,08 kgf that was not different between itself. The result of this study indicate that the use of fiber posts increase their resistance to fracture and improve the prognosis in case of fracture / Doutor
14

Tenacidade à fratura e dureza de porcelana feldspática adicionada de óxido de zircônio : efeito da concentração e da temperatura de sinterização /

Ribeiro, João Gustavo Rabelo. January 2009 (has links)
Resumo: O objetivo deste estudo foi avaliar o efeito da adição de óxido de zircônio, em diferentes concentrações e temperaturas de sinterização, na tenacidade à fratura (KIC) e na dureza Vickers (HV) da porcelana feldspática Duceragold. Foram confeccionados discos cerâmicos (9,0 x 3,0mm; n=10) para os grupos: (G1) Duceragold sem adição de ZrO2, (G2) Duceragold adicionada de 1% de ZrO2, (G3) 2% de ZrO2, (G4) 3% de ZrO2, (G5) 4% de ZrO2, (G6) 5% de ZrO2, (G7) 6% de ZrO2 e (G8) 7% de ZrO2, sinterizados a: (a) 800 ºC, (b) 850 ºC, (c) 900 ºC, (d) 950 ºC e (e) 1000 ºC, totalizando 400 corpos-de-prova. Após a sinterização, em forno Alumini Press, procedeu-se sua inclusão e polimento até lixa 1500 em politriz. A HV foi mensurada em durômetro Buelher, com carga de 9,8 N, por 20 segundos; as imagens obtidas foram capturadas por meio de câmera JVC e os cálculos de KIC, executados com auxílio do software Laica. Para observação da superfície das amostras, foram realizadas fotomicrografias por MEV. Os resultados de KIC e HV foram submetidos a ANOVA e teste de Tukey (p!0,05). Observou-se que, independentemente da temperatura de sinterização, o aumento da concentração de óxido de zircônio, aumenta o KIC, todavia, a partir de 6%, a HV diminui; independentemente da concentração, o aumento da temperatura de sinterização proporciona aumento dos valores de HV, contudo, temperaturas de 950ºC e 1000ºC diminuem o KIC; com o aumento da concentração de óxido de zircônio e da temperatura de sinterização, aumentam o número de poros tanto na fase vítrea da porcelana, quanto na fase dispersa de zircônia. Considerando as propriedades estudadas e a caracterização da superfície, pode-se observar que as amostras com adição de até 4% de óxido de zircônio à porcelana feldspática Duceragold, sinterizadas em temperaturas de até 900ºC apresentam-se como as mais promissoras. / Abstract: The objective of this study was to evaluate the effect of adding zirconium oxide at different concentrations and temperatures of sintering, on the fracture toughness (KIC) and Vickers hardness (HV) of feldspathic porcelain Duceragold. Ceramic discs were prepared (9.0 x 3.0 mm, n = 10) for the groups: (G1) Duceragold without the addition of ZrO2, (G2) Duceragold added 1% of ZrO2, (G3) 2% of ZrO2, (G4) 3% of ZrO2, (G5) 4% of ZrO2, (G6) 5% of ZrO2, (G7) 6% of ZrO2 and (G8) 7% of ZrO2, sintered at: (a) 800 ºC, (b) 850 ºC, (c) 900 ºC, (d) 950 °C and (e) 1000 ºC, totaling 400 specimens of the samples. After sintering at Alumini Press furnace, inclusion and polishing by sandpaper polishing (# 1500) were proceeded. The HV was measured in a Buelher durometer, with a load of 9.8 N for 20 seconds, the images were captured using a JVC camera and calculation of KIC, performed with the aid of software Laica. To observe the surface of the samples were performed by SEM photomicrographs. The results of KIC and HV were submitted to ANOVA and Tukey's test (p ! 0.05). It was observed that regardless of sintering temperature, the concentration of zirconium oxide, increases the KIC, however, from 6%, HV decreases; regardless of the concentration, the increase of sintering temperature gives increased HV values, however, temperatures of 950 °C and 1000 °C decrease the KIC; with increasing concentration of zirconium oxide and sintering temperature, increase the number of pores in the vitreous and dispersed phase of zirconia. Considering the studied properties and characterization of the surface can be observed that the samples with the addition of up to 4% zirconium oxide in Duceragold feldspathic porcelain, sintered at temperatures up to 900 º C are presented as the most promising. / Orientador: Carlos Alberto dos Santos Cruz / Coorientador: José Cláudio Martins Segalla / Banca: Paulo Henrique dos Santos / Banca: Marcos Ribeiro Moysés / Banca: João Neudenir Arioli Filho / Banca: Renata Garcia Fonseca / Doutor
15

Resistência à flexão, resistência à tração diametral e dureza de sistemas cerâmicos para infra-estrutura /

Schalch, Max von. January 2003 (has links)
Orientador: Carlos Alberto dos Santos Cruz / Banca: Renata Garcia Fonseca / Banca: Alma Blásida Concepción Elizaur Benitez Catirse / Resumo: O objetivo deste estudo foi comparar a resistência à flexão, a resistência à tração diametral e a dureza do material de infra-estrutura dos sistemas cerâmicos IPS-Empress 2/Ivoclar (dissilicato de lítio, processado por injeção) e In-Ceram Zirconia/Vita (óxidos de alumínio e zircônio, processados por dupla sinterização). Foram confeccionadas dez amostras de cada material para o ensaio de flexão (em forma de barra, 25mm de comprimento, 5mm de largura, 2mm de espessura - ISO 6872) e 15 amostras para o ensaio de tração diametral (em forma de disco, 6mm de diâmetro, 3mm de espessura). Os testes foram realizados em equipamento MTS 810 (Material Test System - EUA), com célula de carga de 10kN e velocidade de 0,5mm/minuto, gerenciado por programa Test Star II (IBM, EUA). Para o ensaio de dureza, na escala Vickers, cinco fragmentos de cada cerâmica foram incluídos em resina acrílica autopolimerizável JET (Artigos Odontológicos Clássico, Brasil), polidos e submetidos ao teste no durômetro Buheler (EUA), com carga de 1,0kgf por 30 segundos. Os resultados mostraram maior resistência à flexão do material In-Ceram Zirconia (439,88MPa) em relação ao IPS-Empress 2 (226,13MPa). Entretanto, observou-se maior resistência à tração diametral do IPS-Empress 2 (175,08MPa) em relação ao In-Ceram Zirconia (150,47MPa). Para a dureza Vickers, o material In-Ceram Zirconia (972,0VHN) mostrou-se superior em relação ao IPS-Empress 2 (488,33VHN). / Abstract: The aim of this study was to compare flexural strength, diametral tensile strength and hardness of infra-structure ceramic systems IPS-Empress 2/Ivoclar (litium dissilicate, heat-pressed) and In-Ceram Zirconia/Vita (aluminum and zirconium oxides, Slip casting). Ten especimens were made for flexural test (25mm length; 5mm width; 2mm thick - ISO 6872), and 15 especimens for diametral test (6mm diameter; 3mm thick). The tests were done in a MTS 810 machine (Material Test System - USA), with load cell of 10kN and crosshead-speed of 0.5mm/minute, managed by Test Star II software (IBM, USA). Five samples of each ceramic were included in autocured resin JET (Artigos odontológicos Clássico, Brazil), polished and submitted to Vickers hardness test in duromer Buheler (USA), with load of 1.0kgf for 30 seconds. In flexural test, In-Ceram Zirconia (439.88MPa) showed greater strength than IPS-Empress 2 (226.13MPa). However, the IPS-Empress 2 (175.08MPa) showed greater diametral strength than In-Ceram Zirconia (150.47MPa). For hardness, the In-Ceram Zirconia (972.0VHN) showed greater than IPS-Empress 2 (488.33VHN). / Mestre
16

Efeito da ciclagem mecânica na deflexão de cúspides de pré-molares restaurados pela técnica direta e indireta : estudo com strain gauge /

Zamboni, Sandra Regina Oliveira Costa. January 2007 (has links)
Orientador: Lafayette Nogueira Junior / Banca: Lourenço Correr Sobrinho / Banca: Fernando Eidi Takahashi / Resumo: A proposta deste trabalho foi avaliar a deformação cuspídea após aplicação de uma carga oclusal em dentes com restaurações diretas e indiretas tipo inlays em 60 pré-molares hígidos divididos em seis grupos: Grupo 1-dentes hígidos; Grupo 2-dentes preparados; Grupo 3-dentes restaurados com resina composta direta filtek. Z350 (3M ESPE); Grupo 4-dentes restaurados com resina composta indireta Sinfony (3M ESPE); Grupo 5- dentes restaurados com inlays de cerâmica injetada IPS Empress 2 (Ivoclar) e Grupo 6-dentes restaurados com inlays produzidos pelo sistema CAD/CAM (CEREC 2). Todas as restaurações indiretas foram cimentadas com cimento resinoso adesivo RelyX ARC(3M ESPE). Os pre-molares receberam medidores de tensão (strain-gauge 060BG.Excel Sensores Brasil) colados nas superfícies vestibular e lingual que possibilitou a mensuração da deflexão das cúspides força aplicada de 100N na face oclusal dos dentes. Foram feitas medições em 'mü"strain antes e apos a ciclagem mecânica com freqüência de 1Hz. Foram realizados testes ANOVA para medidas repetidas e Tukey para analisar o efeito do tratamento antes e apos a ciclagem mecânica. O teste de Dunnett foi usado para comparar cada tratamento com o controle. Os resultados antes da ciclagem foram em 'mü'strain: Grupo 1- 577,02'mais ou menos'2,70; Grupo 2- 583,37'mais ou menos'2,76; Grupo 3- 579,16'mais ou menos'3,92; Grupo 4- 578,12'mais ou menos'1,38; Grupo 5- 578,68'mais ou menos'1,57 e Grupo 6- 577,53'mais ou menos'1,93 e apos Grupo 1- 577,02'mais ou meno2,70; Grupo 2- 584,38'mais ou menos'0,827; Grupo 3- 579,24'mais ou menos'0,976 Grupo 4- 578,24'mais ou menos'1,05; Grupo 5- 578,74'mais ou menos'0,788 e Grupo 6- 580,54'mais ou menos'0,99. Após analise dos dados concluiu-se que os dentes que receberam preparo cavitário tiveram aumentada significantemente a deflexão de cúspide;...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the cuspal deflection after application of a oclusal load in teeth with direct and indirect inlays restorations in sixty intact premolars divided in six groups: Group 1 - intacts teeth; Group 2 - prepared teeth; Group 3 - teeth restored with direct composed resin filtek. Z350 (3M ESPE); Group 4 - teeth restored with composed resin indirect Sinfony (3M ESPE); Group 5 - teeth restored with inlays of injected ceramics IPS Empress 2 (Ivoclar) and Group 6 - teeth restored with inlays produced by system CAD CAM (CEREC 2). All the indirect restorations had been cemented with resinous cement adhesive RelyX ARC (3M ESPE). Premolars received measurers from tension ('strain-gauge' Modelo 060BG - Excel Sensory - Brazil) glue in the buccal and lingual surfaces that the measurement of the cuspal deflection made possible caused by a force applied of 100N in the oclusal face of teeth. Measurements in 'müstrain had been made before and after the mechanical loading procedures frequently of 1Hz. Analysis of Variance (ANOVA) for repeated measures and test of Tukey was carried before and after the mechanical loading procedures. Dunnett test was used to compare each treatment with the control Group. The results before the mechanical loading procedures in 'mü'strain had been: Group1- 577,02'mais ou menos'2,70; Group2 - 583,37'mais ou menos'2,76; Group3 - 579,16'mais ou menos'3,92; Group4 - 578,12'mais ou menos'1,38; Group5 - 578,68'mais ou menos'1,57 and Group6 - 577,53'mais ou menos'1,93 and the results had after been: Group1- 577,02'mais ou menos'2,70; Group2- 584,38'mais ou menos'0,827; Group3 - 579,24 'mais ou menos'0,976; Group4 - 578,24'mais ou menos'1,05; Group 5- 578,74'mais ou menos'0,788 and Group6 - 580,54'mais ou menos'0,99. After analysis of the data concluded that the teeth that had received preparation cavitario MOD had increased the cuspal deflection...(Complete abstract, click electronic access below) / Mestre
17

Estudo da influência da ciclagem mecânica sobre a resistência de união ao cisalhamento entre uma cerâmica de recobrimento estético e duas cerâmicas infiltradas por vidro /

Landim, Karine Tenório. January 2006 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Osvaldo Daniel Andreatta Filho / Banca: Lafayette Nogueira Junior / Resumo: Este estudo avaliou a influência da ciclagem mecânica na resistência de união ao cisalhamento entre cerâmicas infiltradas por vidro para infra-estrutura (In-Ceram Alumina - Vita Zahnfabrik e In-Ceram Zircônia - Vita Zahnfabrik) e uma cerâmica vítrea de recobrimento (VITA VM7 - Vita Zahnfabrik). Foram preparadas vinte e quatro amostras cilíndricas nas dimensões de 4mm de diâmetro por 5mm de altura para cada cerâmica de infra-estrutura. Posteriormente, a cerâmica de recobrimento estético foi aplicada, resultando em corpos-de-prova com 4mm de diâmetro e 9mm de altura, os quais foram divididos em 4 grupos: ICA; ICAM; ICZ e ICZM. Os grupos ICAM e ICZM receberam ciclagem mecânica, com força de 50N, freqüência de 1Hz, durante 20000 ciclos. O ensaio de cisalhamento foi realizado em máquina de ensaio universal (modelo DL - 1000, EMIC - Equipamentos e Sistemas LTDA., São José dos Pinhais - PR - Brasil) com velocidade de 0,5mm/min e as amostras carregadas até a fratura. As interfaces das amostras pós-fratura foram analisadas em estereomicroscópio (20x) e microscopia eletrônica de varredura. As médias e desvios padrão obtidos foram: ICA (30,04 l 11,74); ICAM (32,17 l 9,59); ICZ (44,33 l 11,47); ICZM (43,52 l 8,33). Os dados obtidos (MPa) foram analisados estatisticamente por meio de análise de variância (ANOVA) dois fatores e teste de Tukey (P<0,05). Os resultados mostraram diferença estatisticamente significante entre os grupos In-Ceram Alumina e In-Ceram Zircônia, porém a ciclagem mecânica não influenciou na resistência de união entre as cerâmicas de infra-estrutura e de recobrimento estético estudadas / Abstract: This study evaluated the influence of cyclic loading on shear bond strength between two glass-infiltrated ceramics for substructure (In-Ceram Alumina - Vita Zahnfabrik and In-Ceram Zirconia - Vita Zahnfabrik) and one glass veneer ceramic (VITA VM7 - Vita Zahnfabrik). Twenty four cylindrical samples with 4mm diameter per 5mm high was to prepare for each ceramics for substructure. Subsequently, the venner ceramic was applied to ceramic substructure, resulting in 4mm diameter per 9mm high specimens. They were divided in four groups ICA; ICAM; ICZ and ICZM. The groups ICAM and ICZM where cyclic loadind from 50N, 1Hz during 20000 cycles. Shear bond testing was performed in a universal testing machine (DL - 1000 model, EMIC - Equipamentos e Sistemas LTDA., São José dos Pinhais - PR - Brasil), with crosshead speed of 0,5mm/min and the specimens were loaded until failure. The interfaces of representative fractured specimens of each group were examined with microscopy (20x) and scanning electron microscopy. The mean values and standard deviations were: ICA (30,04 l 11,74); ICAM: (32,17 l 9,59); ICZ: (44,33 l 11,47); ICZM: (43,52 l 8,33). Data for shear bond strength (MPa) where statistically analysed by variance analysis (ANOVA) two factors and Tukey's test (P<0,05). The results showed statistically significant differences between the groups In-Ceram Alumina and In-Ceram Zirconia, however the cyclic loading effect was not influenced on bond strength between ceramics for substructure and veneer ceramic studied / Mestre
18

Avaliação in vitro da efetividade de associações de agentes clareadores na alteração da cor de dentes manchados por pigmentos sangüineos /

Yui, Karen Cristina Kazue. January 2006 (has links)
Orientador: José Roberto Rodrigues / Banca: Marianne Spalding / Banca: Maria Antonio Pereira / Banca: Sérgio Eduardo de Paiva Gonçalves / Banca: Maria Amélia Máximo de Araújo / Resumo: O objetivo deste estudo foi avaliar in vitro a efetividade de três associações de materiais clareadores na técnica mediata de clareamento de dentes tratados endodonticamente. Foram utilizados 48 pré-molares humanos íntegros, pigmentados artificialmente com sangue humano. Após preparo biomecânico, os canais radiculares foram obturados e o tampão cervical foi confeccionado com 3mm de cimento de fosfato de zinco ao nível da junção amelo-cementária. Os dentes foram divididos em quatro grupos (n=12): C (controle, sem material clareador), A1 (perborato de sódio + água destilada), A2 (perborato de sódio + peróxido de carbamida a 10%) e A3 (perborato de sódio + peróxido de carbamida a 35%). Os materiais clareadores foram trocados aos sete e 14 dias. Concluiu-se que o perborato de sódio associado ao peróxido de carbamida (tanto a 10%, como a 35%) foi mais efetivo do que quando associado à água destilada. / Abstract: The aim of this study was to evaluate in vitro the effectiveness of three associations of bleaching agents on artificially stained pulpless teeth. Forty-eight recently extracted intact human premolars were stained by immersing them in human blood, and divided into four groups. All teeth were endodontically treated and 3mm of zinc phosphate cement was placed at the cementoenamel junction. The teeth were divided into one control group and three test groups (n=12): C) control group, without bleaching agent, A1) sodium perborate with water, A2) sodium perborate with 10% carbamide peroxide, A3) sodium perborate with 35% carbamide peroxide. On days 7 and 14, each pulp chamber was refilled with fresh bleaching paste. Color coordinates of CIELAB color system were measured and assessed with the aid of a dental spectrophotometer (EasyShade®, Vita). It was concluded that sodium perborate mixed with carbamide peroxide (10% or 35%) was more effective than mixed with water. / Doutor
19

Análise da termoplasticidade e adesividade da guta-percha e resilon /

Silveira, Geraldine Faccio da. January 2010 (has links)
Orientador: Mario Tanomaru Filho / Banca: José Maurício dos Santos Nunes Reis / Banca: Yara Teresinha Correa Silva Sousa / Resumo: Objetivo: Analisar a termoplasticidade da guta-percha e Resilon®, submetidos à diferentes condições de testes de termoplastificação, bem como resistência de união dos mesmos à diferentes cimentos endodônticos. Metodologia: Para os testes de termoplasticidade, corpos-de-prova foram confeccionados com dimensões padronizadas dos seguintes materiais: guta percha convencional (GCO); guta percha termoplástica (GTP) e cones Resilon® (RE). Após 24 h, os corpos-de-prova foram submetidos às temperaturas de 50 °C, 60 °C ou 70 °C por 60 segundos conforme o grupo avaliado. Em seguida, receberam uma carga compressiva de 1,0; 3,0 ou 5,0 kg. As imagens dos corpos de prova antes e após os testes foram digitalizadas e analisadas. A capacidade de plastificação dos materiais foi determinada pela diferença das áreas final e inicial dos corpos-de-prova. Para teste de resistência de união, os corpos-de-prova foram confeccionados com dimensões padronizadas para cada material sólido testado: guta-percha convencional (GCO), guta-percha termoplastica (GTP), Resilon® (RE) e Obtura II® (OBT). Os cimentos, AH Plus® (AHP), Endofill (EF), Sealer 26 (S26) e Epiphany SE®. (ESE), foram inseridos em cilindros de alumínio dotados de alça lateral nos quais foram conectados os discos padronizados de cada material. Foi realizado o teste de tração em Máquina de Ensaios Mecânicos Emic DL 2000. Desta forma, dois estudos foram realizados. Na primeira análise os espécimes foram divididos em 12 grupos: grupo 1 (GCO + AHP); grupo 2 (GCO + EF); grupo 3 (GCO + S26); grupo 4 (GCO + ESE); grupo 5 (GTP + AHP); grupo 6 (GTP + EF); grupo 7 (GTP + S26); grupo 8 (GTP + ESE); grupo 9 (RE + AHP); grupo 10 (RE + EF); grupo 11 (RE + S26) e grupo 12 (RE + ESE). A segunda análise correspondeu à avaliação da resistência de união das associações: grupo 1 (OBT + AHP); grupo 2 (OBT + ESE); grupo 3 (RE + AHP)... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Aim: The aim of the study was to evaluate the thermoplasticity and bond strength properties of conventional and thermoplastic gutta-percha and Resilon. Metodology: To thermoplasticity test, specimens with standardized dimensions were fabricated from the materials: conventional and thermoplastic Endopoints gutta-percha, and Resilon. After 24 h, the specimens were placed in water at 50º, 60º or 70 oC for 60 seconds and thereafter positioned between two glass slabs. Each set was compressed by a 1,0; 3,0 or 5,0-kg weight. Digital images of the specimens before and after compression were obtained and analyzed. The thermoplasticity of each material was confirmed by the difference between final and initial areas of each sample. To the analyze of conventional, thermoplastic gutta-percha and Resilon, disks were prepared with standardized dimension: convencional gutta-percha (GCO), thermoplastic gutta-percha (GTP), Resilon (RE) and Obutra II (OBT). The root canal sealers: AH Plus (AHP), Endofill zinc oxide and eugenol sealer (EF), Sealer 26 epoxy.resin sealer (S26), and Epiphany SE methacrylate-based sealer (ESE) were inserted in to metallic rings .The metallic rings were positioned over the core material disks and after set of the sealers the specimens were subjected to tensile bond strength testing using a mechanical testing machine (0.5 mm/min). The ultimate tensile bond strength was expressed in MPa. The first analysis, 12 groups were made: group 1 (GCO + AHP); group 2 (GCO + EF); group 3 (GCO + S26); group 4 (GCO + ESE); group 5 (GTP + AHP); group 6 (GTP + EF); group 7 (GTP + S26); group 8 (GTP + ESE); group 9 (RE + AHP); group 10 (RE + EF); group 11 (RE + S26) and group 12 (RE + ESE). For the second analysis, 4 groups were evaluated: group 1 (OBT + AHP); group 2 (OBT + ESE); group 3 (RE + AHP) e group 4 (RE + ESE).All data were statistically analyzed by ANOVA (P<0.05)... (Complete abstract click electronic access below) / Mestre
20

Avaliação in vitro da citotoxicidade e genotoxicidade de diferentes cimentos endodônticos em fibroblastos V79 /

Silva, Gleyce Oliveira. January 2011 (has links)
Orientador: Carlos Henrique Ribeiro Camargo / Banca: Bruno das Neves Cavalcanti / Banca: Márcia Carneiro Valera / Resumo: Cimentos endodônticos podem liberar componentes tóxicos que interagem com os tecidos periapicais. A proposta deste trabalho foi avaliar a citotoxicidade e genotoxicidade de quatro cimentos endodônticos (EndoREZ, RoekoSeal, AHPlus e cimento experimental à base de óleo-resina da Copaifera multijuga) utilizando ensaios biológicos. Os cimentos foram mixados e incubados em estufa de umidade relativa a 37°C com 5% CO2 por 24 h. A exposição do meio de cultura aos cimentos ocorreu após 12 h do endurecimento dos cimentos. Células V79 foram expostas às diluições dos extratos por 24 h e a sobrevivência celular foi mensurada fotometricamente. A viabilidade celular foi mensurada pelo teste de MTT em espectrofotômetro e a genotoxicidade, indicada pela formação de micronúcleos, foi determinada após 24h do período de exposição. Os resultados da taxa de sobrevivência celular e a quantidade de danos ao DNA foram estatisticamente analisados pelo teste de Kruskal-Wallis (p<0,05). A citotoxicidade em relação ao grupo controle decresceu na seguinte ordem EndoREZ > Copaíba ≥ AH Plus > RoekoSeal. A formação de micronúcleos (MN) para indicar a genotoxicidade foi induzida somente pelos extratos do EndoREZ, sendo mais genotóxico que o EMS (controle positivo) / Abstract: Endodontic sealers could release toxic components that may interact with periapical tissues. The purpose of this study was to evaluate the cytotoxicity and genotoxicity of four endodontic sealers (EndoREZ, RoekoSeal, AHPlus and experimental root canal sealer- based on Copaifera multijuga oil-resin) using routine cell biology techniques. The sealers were mixed and incubated in a humidified incubator at 37°C with 5% CO2 in air for 24 h. The exposure of the culture medium to the sealers occurred after 12 h of cure. V79 cells were exposed to dilutions of this extracts for 24 h and cell survival was measured photometrically. The cell viability was measured by MTT test in a spectrophotometer and the genotoxicity as indicated by the formation of micronuclei was determined after a 24 h exposure period The results of the cell survival rates and the amount of DNA damage was statistically analyzed for Kruskal-Wallis (p<0.05) test. The ranking of cell survival from the most to the least toxic material was: EndoREZ> Copaíba ≥ AH Plus > RoekoSeal. The formation of micronuclei (MN) to indicate genotoxicity was induced only by extracts of EndoREZ, being more genotoxic than EMS (positive control) / Mestre

Page generated in 0.1214 seconds