• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Variaveis associadas a determinação do limiar basal de resposta da polpa dental ao estimulo eletrico / Variables associated to pulpal threshold determination with electrical stimulus

Branco, Filipe Polese 28 February 2007 (has links)
Orientador: Maria Cristina Volpato / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T06:11:11Z (GMT). No. of bitstreams: 1 Branco_FilipePolese_D.pdf: 1567364 bytes, checksum: 49e978a109d02d28d81bb848765787cd (MD5) Previous issue date: 2007 / Resumo: O uso do pulp tester ainda não está padronizado na literatura. Assim, o objetivo deste trabalho foi determinar as condições ideais para determinação do limiar basal de resposta pulpar a estímulo elétrico. Duzentos e cinqüenta e seis voluntários sadios e com dentes responsíveis a estímulo elétrico foram selecionados e divididos em 7 estudos. Estímulo elétrico foi aplicado aos dentes em testes sucessivos, com intervalo de 2 minutos entre eles. As variáveis estudadas foram: número de medidas e de voluntários, necessidade de secagem do dente, influência da solução condutora, do operador, do período do dia e da temperatura ambiente, do grupo étnico-racial do voluntário, e do uso de ácido mefenâmico e nimesulida. Foi também avaliada a sensibilidade dolorosa dos voluntários por meio da escala analógica visual (EAV). Os resultados de limiar basal de resposta pulpar foram submetidos aos testes t e de Tukey e os de EAV aos testes de Wilcoxon e Friedman (a=0,05). A média obtida com 3 medidas não diferiu das obtidas com número maior de medidas; a secagem prévia do dente e o uso de gel de flúor neutro levaram a menores valores de limiar pulpar; voluntários de ambos os gêneros apresentam maiores valores de limiar pulpar quando avaliados por operador do gênero feminino. Não houve diferença no limiar pulpar entre os horários 8h, 11h, 14h e 17h, entre as sessões com temperatura ambiente inferior a 15oC ou superior a 25oC, bem como entre as raças amarela, branca e preta, e após administração de dose única de ácido mefenâmico ou de nimesulida quando comparados a placebo. Concluiu-se que para a determinação do limiar basal pulpar após aplicação de estímulo elétrico deve-se fazer a média de pelo menos 3 medidas consecutivas e utilizar no mínimo 20 voluntários; a secagem prévia do dente pode levar à melhor condução do impulso; o gel de flúor neutro deve ser a substância condutora de escolha; o gênero do operador pode exercer influência nos voluntários; o limiar basal pulpar não apresenta ritmo circadiano e não sofre interferência da temperatura ambiente, da etnia do voluntário ou da nimesulida e ácido mefenâmico, administrados em dose única / Abstract: There are some unclear aspects about electrical pulpal threshold measure. The objective of this study was to determine the ideal conditions for pulpal threshold measure. Two hundred and fifty six healthy volunteers with teeth able to respond to electrical stimulus were selected and divided in 7 studies. Pulpal threshold was evaluated by means of an electric pulp tester, with a 2min interval between tests. The variables studied were: number of measures and volunteers, and the influence of moisture, conductive media, gender of the operator, room temperature, period of the day, volunteers¿ ethnicity, and administration of mefenamic acid and nimesulide. Pain sensibility was evaluated by Analogue Visual Scale (VAS). Pulpal threshold data were evaluated by ANOVA and t and Tukey tests; VAS results were submitted to Wilcoxon and Friedman tests. Results: the mean obtained with 3 measures was not dfferent than the obtained with higher number of measures; lower pulpal threshold means were obtained with previous dryness of teeth and neutral fluoride gel as conductive media; male and female volunteers presented higher pulpal threshold mean when evaluated by female operator; no difference in pulpal threshold were observed among ethnic Brazilian groups, yellow, white, and black, among periods of the day (8h, 11h, 14h and 17h), between room temperature bellow 15oC and above 25oC and with the administration of mefenamic acid and nimesulid when compared to placebo. It was concluded that at least 20 volunteers must be measured and 3 measures must be performed to determine electrical pulpal threshold; dryness of teeth can improve electrical conductance; operator gender can influence the volunteers¿ pulpal threshold; pulpal threshold is not influenced by room temperature, volunteer ethnicity, and single dose dministration of mefenamic acid and nimesulide. No circadian pattern was observed for pulpal threshold / Doutorado / Farmacologia, Anestesiologia e Terapeutica / Doutor em Odontologia
2

Identificação imunohistoquimica de celulas imunologicas e inflamatorias em polpas dentais normais e inflamadas / Immunohistochemical identification of immunocompetent and inflammatory cells in healthy and inflamed dental pulps

Almeida, José Flávio Affonso de, 1979- 05 March 2006 (has links)
Orientador: Alexandre Augusto Zaia / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T06:09:06Z (GMT). No. of bitstreams: 1 Almeida_JoseFlavioAffonsode_D.pdf: 2803790 bytes, checksum: 523bf1872c348721161eafd32bb6f736 (MD5) Previous issue date: 2006 / Resumo: Este estudo teve como objetivos identificar por técnica de imunohistoquímica linfócitos T4, linfócitos T8, linfócitos B, macrófagos e mastócitos em tecidos pulpares normais e inflamados de dentes humanos e correlacionar a presença dessas células com os sinais e sintomas apresentados pelos pacientes e aspectos clínicos dos dentes. Após a determinação do diagnóstico clínico das condições pulpares, 24 polpas normais e 18 polpas inflamadas foram coletadas de dentes extraídos clivados ou por extirpação em dentes que foram submetidos à endodontia. As polpas foram processadas histologicamente, sendo que uma secção tecidual de cada amostra foi corada por hematoxilina e eosina e as demais foram utilizadas para a imunohistoquímica. As lâminas foram analisadas em microscopia de luz. Cinco campos com maior intensidade de marcação foram capturados, tiveram suas áreas mensuradas e o número de células contado. Em polpas normais, os linfócitos T8 apresentaram maior número de células marcadas, seguidos pelos linfócitos T4, macrófagos, linfócitos B e mastócitos. Diferenças significantes foram encontradas, com maior número de linfócitos T8 quando comparados aos linfócitos B e mastócitos (Kruskal-Wallis - p< 0,05). Em polpas inflamadas, os macrófagos apresentaram maior número de células positivas seguidos dos linfócitos T8, T4, B e mastócitos. Não houve diferença estatística significante entre as densidades das células estudadas em polpas inflamadas (Kruskal-Wallis - p> 0,05). Dessa forma, concluiu-se que os linfócitos T4, T8 e B, macrófagos e mastócitos podem ser identificados em diferentes proporções nos tecidos pulpares normais e inflamados. Entretanto, não houve correlação entre a sintomatologia apresentada pelos pacientes e o aumento do número dessas células em todos os tecidos pulpares classificados clinicamente como inflamados / Abstract:The aim of this study was to identify by immunohistochemical technique T4 lymphocytes, T8 lymphocytes, B lymphocytes, macrophages and mast cells in normal and inflamed human dental pulps and to correlate the presence of these cells to the signals and symptoms presented by the patients and the teeth clinical aspects. After the clinical diagnoses, 24 normal dental pulps and 18 inflamed dental pulps were collected from extracted teeth or by extirpation during endodontic procedures. After dental pulp histological procedures, one tissue section from each specimen was stained with hematoxylin and eosin and the other sections were used to immunohistochemical analyses. The slides were analyzed by light microscopy. Five fields with more intensive immunostaining were captured, measured and the positive cells were counted. In normal pulps, T8 lymphocytes presented more positive cells followed by T4 lymphocytes, macrophages, B lymphocytes and mast cells. Statistical significance was founded with more T8 lymphocytes than B lymphocytes and mast cells (Kruskal-Wallis ¿ p< 0.05). In inflamed dental pulps, macrophages presented more positive cells, followed by T8, T4, B lymphocytes and mast cells. These data were not statistically significant (Kruskal-Wallis ¿ p> 0.05). It was concluded that T4, T8 and B lymphocytes, macrophages and mast cells could be identified with different rates in normal and inflamed dental pulps. However, no correlation was detected between the patient¿s symptomatology and these cells increase in all inflamed dental pulps / Doutorado / Endodontia / Doutor em Clínica Odontológica
3

Utilização de microesferas de poli (L-acido-latico) contendo medicamento no tratamento de perda do tecido dental / Use of microspheres of poly (L-lactide acid) contends medication in the treatment of loss of the tissue dental

Bernatavicius, Sergio Tadeu 09 January 2004 (has links)
Orientador : Eliana Aparecida de Rezende Duek / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-04T01:54:38Z (GMT). No. of bitstreams: 1 Bernatavicius_SergioTadeu_M.pdf: 9386061 bytes, checksum: 9e736c52e1042de3187574f10e183c68 (MD5) Previous issue date: 2004 / Resumo: Um dos pontos que deve ser considerado de difícil solução no Brasil, é a perda dentinária. Vários materiais tem sido estudados para minimizar o problema, mas nenhum atende às necessidades de tal aplicação. Nesse sentido, o objetivo do presente avaliar a biocompatibilidade do Poli (L-ácido-Iático), PLLA, contendo vancomicina e piroxicam no tratamento de grandes perdas de dentina onde pode ou não ocorrer a exposição da polpa dental, casos onde a exposição leva ao tratamento endodontico ou exodontia. Para tanto, foram realizados estudos in vivo em coelhos e humanos, ambos aprovados pelo Comitê de Ética em Pesquisa da Universidade Estadual de Campinas parecer número 490/2003.Os estudos em coelhos foram realizados utilizando-se de um modelo experimental onde foi implantado as microesferas contendo medicamento nos incisivos centrais e após 20, 40, e 60 dias os dentes foram cortados e submetidos à análise histológica. Após 20 dias de implante, verificou-se regiões centrais de hipocalcificações em relação ao implante e formação de pontos de dentina. Não foi localizado processo inflamatório em função da utilização dos medicamentos. Após 40 dias verificou-se a que a calcificação começa por áreas globulosas que crescem e se fundem, porém o processo muitas vezes é imperfeito, resultando áreas de matriz orgânica não calcificada; são as áreas interglobulares. Após 60 dias, verificou-se a formação de tecido de normalidade o que demonstra a eficácia das microesferas com medicamento como material reparador. A análise in vivo em humanos se fez necessária para avaliar a resposta frente à aplicação do material, seu efeito antiinflamatório e analgésico em casos de exposição pulpar e grande perda dentinária, além da avaliação do retomo da função ao elemento dental, ou seja, controle da dor e possibilidade de mastigação normal. Observou-se após 60 dias que todos os pacientes implantados não apresentaram dor a nenhum dos testes realizados e mantinham a vitalidade pulpar, as microesferas com medicamento aqui também se mostraram eficazes no controle antiinflamatório e infeccioso. O estudo in vivo indicou que as microesferas de PLLA contendo vancomicina e piroxicam apresentam grande potencial para serem utilizadas para aplicação em questão, já que o material favorece a formação de uma neodentina e controla os processos inflamatório e infeccioso / Abstract: One of the points that it should be considered of difficult solution in Brazil, is the loss dentine. Several materials have been studied to minimize the problem, but none assists to the needs of such application. In that sense, the objective of the present to evaluate the biocompatibility of the Poly (L-lactide acid), PLLA, contends vancomicina and piroxicam in the treatment of great dentin losses where cannot or not to happen the exhibition of the dental pulp, cases where the exhibition takes to the treatment endodontic or exodontia. For so much, studies in was accomplished In vivo in rabbits and humans, both approved by the Comitê de Ética em Pesquisa da Universidade Estadual de Campinas to seem number 490/2003. The studies in rabbits were accomplished being used of an experimental model where it was implanted the microesferas contends medication in the incisive central and after 20, 40, and 60 days the teeth were cut and submitted to the analysis histological. After 20 days of it implants, it was verified central areas of hipocalcification in relation to the it implants and formation of dentin points. Inflammatory process was not located in function of the use of the medications. After 40 days the one was verified that the calcification begins for areas interglobules that grow and they are founded, even so the process a lot of times it is imperfect, not resulting areas of organic matrix not calcified; they are the areas interglobules. After 60 days, the formation of normality tissue was verified that demonstrates the effectiveness of the microspheres with medication as reparative material. The analysis in vivo in humans if made necessary to evaluate the answer front to the application of the material, its effect antiinflammatory and analgesic in cases of exhibition pulp and great loss dentine, besides the evaluation of the return of the function to the dental element, that is to say, control ofthe pain and possibility of normal mastication. It was observed after 60 days that ali the implanted patients didn't present pain to none of the accomplished tests and they maintained the vitality pulpar, the microspheres with medication here was shown also effective in the control antiinflammatory and infectious. The study in vivo it indicated that the microspheres of PLLA contends vancomicina and piroxicam they present great potential for they be used for application in subject, since the material favors the formation of a neodentine and it controls the inflammatory and infectious processes / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica

Page generated in 0.6979 seconds