• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • Tagged with
  • 17
  • 17
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeitos do atordoamento eletrico, da estimulação eletrica e da desossa a quente na qualidade da carne do peito (Musculo Pectoralis major) de frango

Contreras Castillo, Carmen Josefina 10 November 1995 (has links)
Orientador: Nelson Jose Beraquet / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-20T20:13:16Z (GMT). No. of bitstreams: 1 ContrerasCastillo_CarmenJosefina_D.pdf: 5353537 bytes, checksum: d9c089ba4a208271b6ffc0f1a1393599 (MD5) Previous issue date: 1995 / Resumo: O presente estudo foi realizado com o objetivo de verificar os efeitos do atordoamento estimulação elétrica e desossa a quente na carne de peito de frango. Num primeiro estudo determinou-se o efeito do uso do atordoamento elétrico a voltagens de 20, 40, 80 e 100V a 60Hz e o uso de al ~as freqüências (200. 350. 600 e 1000Hz). com 40V. Determinou-se efeito desses tratamentos na eficiência da sangria, incidência de lesões e força de liberação das penas. A eficiência da sangria para 20 e 40V à freqüência de 60Hz Variou de 49.6 a 55.3% respectivamente. O uso de altas freqüências resultou em eficiência de 56.2% à 350Hz e 73.1% a 1000Hz, mas sem apresentar diferença (P<0,05) com relação tratamento de atordoamento a 60Hz/40V. A qualidade geral da foi melhor da carcaça para atordoamentos efetuados a 60Hz/(20 e 40V) e a 1000Hz/40V. As medidas de força de cisalhamento mostraram que atordoamento a 1000Hz. 40V influenciou positivamente a maciez da carne de peito. Também o efeito negativo da desossa a quente sobre a maciez cisalhamento foi atenuado, obtendo-se força de 7.9kgf/g que corresponde à maciez aceitável. A avaliação sensorial confirmou o observado pela medida objetiva da textura. Todavia. Não se constatou diferença significativa nos atributos de maciez, suculência e qual idade global entre a carne de peito proveniente de aves atordoadas e não atordoadas. O pH de músculo do peito após atordoamento foi similar para as duas condições de atordoamento, 60 e 1000Hz, em cada um dos estágios do abate, variando de 6.20 após sangria a 5.72 após 24h. No processo sem atordoamento, o pH variou de 5.90 após sangria a 5.63 com 24h post-mortem. A quebra do ATP determinado pelo valor R no músculo do peito foi mais lento em aves atordoadas eletricamente. variando de 0,86 após sangria, a 1,41 após 24h, para ambos os tipos de desossa. Observou-se um rápido esgotamento do glicogênio para as aves não atordoadas, em comparação com as aves atordoadas. O efeito das condições de atordoamento na cor do músculo do peito não foi significativo (P>0,05). Num segundo estudo, determinou-se inicialmente que um tempo de estimulação elétrica de 30s resultou em menor força de cisalhamento (8,0 kgf/g) do que um tempo de 45s (8,7 kgf/g). O efeito da estimulação elétrica CEE) por 30s. nas carcaças atordoadas a 60Hz ou 1000Hz com 40Y. ~oi então determinado. Os peitos das aves atordoadas e estimuladas apresentaram forças de cisalhamento menores, conforme foram aumentados os níveis de voltagem, apresentando diferença significativa (P<0,05) com relação às amostras provenientes das aves não estimuladas. A estimulação elétrica diminuiu o efeito negativo da desossa a quente na maciez da carne de peito, o tipo de desossa influenciou a cor (P<0.05), mostrando que a desossa a quente confere maior luminosidade e menor teor de vermelho. Num terceiro estudo. verificou-se o efeito dos melhores tratamentos obtidos da interação das condições de atordoamento. EE e tipo de desossa, na maciez da carne de peito. As amostras com menores valores de força de cisalhamento de 4.9 e 4.4kgf/g, tratadas a 60 e 1000Hz para o atordoamento e estimuladas a 45 e 100V, ambas obtidas pela desossa convencional, foram consideradas macias. Com a desossa a quente, aves atordoadas a 60Hz e estimuladas a 80V, assim como aves atordoadas a 1000Hz e estimuladas a 100V, foram as que apresentaram menores valores de força de cisalhamento de 8,2 e 8,0 kgf/g. respectivamente. Em relação à cor (valores L* e a*), as amostras provenientes de aves atordoadas a 1000Hz e estimuladas a 100V não apresentaram diferenças em relação às amostras não estimuladas na desossa a quente. Por outro lado, as amostras do peito de aves atordoadas (60Hz/40v) e estimuladas (45v) desossada convencionalmente e outro tratamento com o mesmo atordoamento e estimulada (80V) desossada a quente apresentaram menor valor de L* e maior valor de a* em relação às amostras não estimuladas para ambos tipos de desossa, o uso da EE acelerou a queda do pH em todos os tratamentos. sendo mais acentuada para a desossa a quente. O valor R teve um comportamento covariante em relação à queda de pH. acompanhado pela diminuição do glicogênio e aumento do ácido láctico / Abstract: The objective of this study was to investigate the effect's of the electrical stunning, stimulation and hot deboning on the quality of broiler breast meat. In the first stage the effect of electrical stunning on the quality of broiler breast meat using 20, 40, 80 and 100V at 60Hz and also high frequencies such as 200, 350, 500 and 1000Hz, as determined. The use of high frequencies produced higher efficiencies in the bleeding, giving 56,2% at, 350Hz and 73.1% at 1000Hz, at a voltage of 40V. both. In terms of general quality of the carcass the best conditions were obtained with the stunning at 60Hz (20 e 40V) and at 1000Hz/40V. The shear value showed that stunning at 1000Hz. 40V had positive influence on the tenderness of the breast meat. Under the same stunning conditions the negative effect. of the hot deboning as decreased, showing a shear value to 7.9kgf /g. Sensory analysis showed that, the stunning at 1000Hz/40V had a positive effect on the tenderness of the chicken breast meat. However, there was no significant difference in tenderness, juiceness and overall quality of the meat from treated and untreated birds. The pH of the breast meat was similar for both 60Hz and 1000Hz treatment's. It varied from 6,20 after bleeding to 5,72 24h post-mortem. In untreated birds breast, the pH varied from 5,90 immediately after bleeding to 5.63 after 24h post-mortem. The breakdown of ATP (R value), in the breast muscle of electrically stunned birds, varied from 0,86 after bleeding to 1,41 after 24h post-mortem, for both ~types of deboning. A rapid decrease in the glycogen levels was observed for untreated broiler when compared with treaded broiler. The effect of the treatment conditions on the color of the breast muscle was not significant (P>0,05). In a second stage, it was initially determined that a electric simulation time of 30s resulted in better tenderness (8,Okgf /g) than a time of 45s (8,7kgf /g). As a consequence the effect of electrical simulation (ES), on the treated carcass al 60Hz and 1000Hz al 40V, was determined for a 30s treatment time. The samples of electrically stunned and simulated broiler meal showed lower shear values according to increasing voltage levels, with significative difference (P<0, 05) when compared to control samples which were not stimulated. The electrical simulation also decreased the negative effect of hot deboning on tenderness. Deboning had a significanl influence to the color (P<0,05), showing that the hot deboning gives higher parameter L* and lower a*. In a third stage, the effect of stunning, ES and deboning on the tenderness of the breast meat was verified. Those samples showing values of 4,9 and 4,4kgf/g for the shear force, which were treated at 60 and 1000Hz and simulated at 45 and 100V with conventional deboning, were considered tender. In the hot deboning, broiler treated at 60Hz and simulated at 80V, as well as broiler treated at 1000Hz and simulated at 100V, showed similar values for shear force (8,0 - 8.,2kgf/g) / Doutorado / Doutor em Tecnologia de Alimentos
2

Determinação do prognostico de pacientes com lesão medular submetidos a estimulação eletrica neuromuscular e fisioterapia convencional, atraves da avaliação fisioterapica, avaliação clinica asia e potencial evocado somato-sensorial

Peixoto, Beatriz de Oliveira 18 December 2002 (has links)
Orientador: Elizabeth Maria Aparecida B. Quagliato / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-03T15:11:13Z (GMT). No. of bitstreams: 1 Peixoto_BeatrizdeOliveira_D.pdf: 9115412 bytes, checksum: d6996f3af9dfc52b429e7d9120ede40d (MD5) Previous issue date: 2002 / Resumo: Este estudo avaliou o diagnóstico e o prognóstico de pacientes com lesão medular através do potencial evocado sômato sensorial (PESS), avaliação ASIA (classificação neurológica da lesão medular e medida de independência funcional (FIM) e escala de deficiência) e avaliação fisioterápica. O efeito da estimulação elétrica neuromuscular (EENM) foi comparado ao tratamento fisioterápico convencional (FC). Foram estudados 19 pacientes com lesão medular, com idade de 16 a 50 anos e de ambos os sexos, que foram divididos em 2 Grupos: Grupo A ¿ EENM -09 pacientes paraplégicos e tetraplégicos pertencentes ao Programa de Estimulação Elétrica Neuromuscular (PEENM) e Grupo B - FC ¿ 10 pacientes paraplégicos e tetraplégicos pertencentes ao Programa do Tratamento Fisioterápico Convencional (PFC). Os dados foram submetidos à análise descritiva através de tabelas de freqüência e medidas de posição e dispersão. Para comparar os dois grupos em relação às variáveis da avaliação ASIA, foi utilizado o teste t de student. Para comparar a primeira e segunda avaliação para cada grupo, em relação as variáveis da avaliação ASIA, foi realizado o teste t student. Para comparar os dois grupos com relação às variáveis categóricas da avaliação fisioterápica, foi utilizado o teste Exato de Fisher. O nível de significância adotado foi de 0,05. A análise estatística revelou uma melhora nas respostas das avaliações ASIA, avaliação fisioterápica tanto no PEENM e PFC, sem diferença entre os mesmos. Em relação ao PESS, o paciente que mostrou potencial evocado normal obteve maior progresso na medida de independência funcional (FIM) e escala de deficiência ASIA em comparação com os outros pacientes. Estas análises levaram à avaliação da viabilidade de um Programa de Estimulação Elétrica Neuromuscular como complemento do Programa de Fisioterapia Convencional em pacientes com lesão medular na fase crônica. A avaliação da ASIA e avaliação fisioterápica complementaram, no diagnóstico e prognóstico de pacientes com lesão medular. O tamanho da amostra residual impediu que se avaliasse estatisticamente o papel de um resultado do PESS normal no prognóstico dos pacientes, embora empiricamente esse pareça ser o caso / Abstract: We evaluate herein diagnosis and prognosis in patients with traumatic medullary injury in their chronic phase treated with neuromuscular electric stimulation and compared with other similar patients who underwent conventional treatment. These patients were evaluated by somatosensory evoked potentials, the ASIA scale for medullary trauma (neurological classification of medullary lesion and functional independence measure and deficiency scale) and physical therapy-oriented clinical evaluation. Evoked potentials were correlated with prognosis in both groups of patients, irrespective of their treatment. This was done by following up 19 paraplegic and tetraplegic patients of both sexes divided into two groups: 9 patients undertook the experimental Neuromuscular Electric Stimulation Programme (EENM) and 10 patients underwent our standard physical therapy treatment (PFC). Data so obtained were submitted to descriptive analysis by frequency tables and position and dispersion measures. The EENM and PFC groups were compared by Student's Test. Evaluations of either group before and after treatment were compared by Student's paired t Test. Categorical variables were compared by means of Fisher's Exact Test. In all cases a 0,05 level of significance was adopted as norm. This statistic analysis revealed an increase both in ASIA scores and an inprovement in the clinical evaluation in both groups irrespective of the treatment employed. As for the somatosensory evoked potentials, the only patient with normal responses obtained the widest improvement in functional indepencence measure evaluation. These analyses showed that EENM gives results similar to those of PFC in the treatment of chronic medullary injury. The rather reduced size of the remaining group did not permit the statistical evaluation of a normal somatosensory evoked response in the prognosis, even though it seems empirically that it seems to be a prognostic indicator / Doutorado / Ciencias Biomedicas / Doutor em Ciências Médicas
3

Avaliação de diferentes tecnologias para o amaciamento da carne bovina in natura

Fernandes, Jose Roberto 11 August 2018 (has links)
Orientador: Nelson J. Beraquet / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-11T23:53:09Z (GMT). No. of bitstreams: 1 Fernandes_JoseRoberto_M.pdf: 34092870 bytes, checksum: 8a300b8be8d4e88aac928fa1d9e77929 (MD5) Previous issue date: 2000 / Resumo: Diversos levantamentos realizados ao redor do mundo apontam a maciez como o principal atributo desejável pelo consumidor quando da aquisição de carne bovina in natura. Entretanto, no Brasil, diversos fatores inerentes à obtenção deste tipo de matéria-prima tem influência direta em seus atributos de textura: raça dos animais, idade de abate, condição sexual e manejo das carcaças no postmortem. Neste trabalho foram pesquisados os efeitos da utilização de diferentes técnicas visando primariamente o amaciamento da carne bovina. Assim, a partir do abate de onze fêmeas 80S indicus (cinco Nelore e seis Guzerá) foram avaliadas a maturação em contrafilés (Longissimus dorsl) utilizando-se diferentes tempos (7, 14, 21 e 28 dias) em duas faixas de temperaturas (O-2°C e 6-8°C) combinada ou não à estimulação elétrica das carcaças (220V e O,5A11minuto). Foi testado também o uso do cloreto de cálcio como agente acelerador do processo de maturação submetendo amostras injetadas 24 horas postmortem à comparação.com as amostras controle considerando a mínima diferença significativa ao nível de 5% pelo método ANOVA ¿Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital. / Abstract: All over the world studies describe tenderness as the most important attribute for the consumers which buy beef retaiI cuts. However there are many factors of brazilian beef cattle breeding which have direct influence in meat texture as animais breed type, slaughter age, sexual condition and wrong carcass handling at the postmortem. In this study the effects of the utilization of different methods to improve tenderness in beef were studied. By this way, starting from the slaughter of 11 80S indicus females (5 from nelore breed and 6 from guzerá breed), the Longissimus dorsi musele was deboned and aged using different times (7, 14, 21 and 28 days) and temperatures (O-2°C and 6-8°C) for instrumental and sensorial evatuations. Before the aging proeess the samples were chosen for electrical stimulation treatment or were not. The calcium chloride using to improve the aging process was also tested ...Note: The complete abstract is available with the full electronic digital thesis or dissertations. / Mestrado / Mestre em Tecnologia de Alimentos
4

A excitabilidade celular : uma formalização matematica baseada no modelo de Hodgkin-Huxkey e sua extensão as celulas cardiacas

Bassani, José Wilson Magalhães, 1953- 14 July 2018 (has links)
Orientadores: Maria Adelia Collier Farias, Armando Freitas da Rocha / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-14T03:14:44Z (GMT). No. of bitstreams: 1 Bassani_JoseWilsonMagalhaes_M.pdf: 1091540 bytes, checksum: 2606c291ec5b7730356e7d31bd610c0a (MD5) Previous issue date: 1979 / Resumo: Neste trabalho é apresentado um cálculo para a excitabilidade celular com base na dinâmica e geometria do modelo de Hodqkin-Huxley para as membranas neurais. Uma extensão desse cálculo às células cardíacas é apresentada com base no modelo de McAllister, Noble e Tsien que descreve a dinâmica das fibras cardíacas de Purkinje. Como consequência do cálculo da excitabilidade celular, é ainda formalizado o conceito de limiar de excitação. O estudo dos processos de codificação celular e dos acoplamentos entre células cardíacas constituem implicações futuras dessa nova abordagem. / Abstract: Not informed. / Mestrado / Mestre em Engenharia Elétrica
5

Aplicação de tecnicas de engenharia no estudo de celulas cardiacas isoladas : medição de [Ca27] e limiar de estimulação

Gomes, Paulo Alberto Paes 22 December 1997 (has links)
Orientador: Jose Wilson Magalhães Bassani / Tese (doutorado) - Universidade Estadual de Campinas. Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-23T05:29:09Z (GMT). No. of bitstreams: 1 Gomes_PauloAlbertoPaes_D.pdf: 8372969 bytes, checksum: 3b3ed01cb6c16c960f7392127e548f17 (MD5) Previous issue date: 1997 / Resumo: Vários eventos fisiológicos importantes são governados por variações na concentração intracelular de cálcio, ['CA POT. 2+¿]i. Na célula cardíaca, variações na ['CA POT. 2+¿]i são responsáveis pelo disparo e controle da força e curso temporal da contração. Neste trabalho estudamos a teoria que fundamenta o uso do Método da Razão, na quantificação de ['CA POT. 2+¿], a partir da medição de fluorescência emitida por indicadores como indo-1 e fura-2. Um sistema de microscopia de fluorescência completo, para ser utilizado com o indo-1, foi projetado e construído. O sistema foi utilizado no estudo dos transientes de cálcio em miócitos cardíacos isolados de ratos durante o desenvolvimento pós-natal (idades: 3 - 6; 13 - 16; 28 - 35 e 180 dias). Apesar dos parâmetros de calibração não se manterem constantes nos diversos grupos, as características dos transientes não mostraram diferenças estatisticamente significativas (['CA POT. 2+¿] diastólico 180nM; ['CA POT. 2+¿] pico 1¿mu¿M e fwhm 0.35ms). Estudando o limiar de estimulação elétrica pudemos comprovar experimentalmente que ele diminui com o desenvolvimento do animal, devido à modificação da geometria das células, como previsto pela teoria / Abstract: Important physiological events are governed by changes in intracellular 'CA POT. 2+¿ concentration (['CA POT. 2+¿]i). In cardiac cells, ['CA POT. 2+¿]I changes are resposible for triggering and controlling the strength and timecourse of contractions. In this work, we studied the fundamental theory for the ratio method, a method to quantitate ['CA POT. 2+¿] from the ratio of fluorescence emitted by a ratiometric 'CA POT. 2+¿ indicator, such as indo-1 and fura-2. Additionally, a complete microscopic system for measuring indo-1 fluorescence was designed and constructed. This system was applied for measuring 'CA POT. 2+¿ transients in cardiac myocytes isolated from rats during post-natal development (ages: 3-6; 13- 16; 28-35 and 180 days). Although the calibration parameters were not the same for all ages, diastolic and peak ['CA POT. 2+¿]i and duration of the 'CA POT. 2+¿ transients were not significantly different ( 180 nM , 1¿mu¿M and 0.35 s, respectively). To explain the field stimulation process of the cells at different ages we developed a simple model based on the eletromagnetic theory. Measured threshold for field eletrical stimulation was age-dependent and was found to be related to the cell geometry, as predicted by the model / Doutorado / Automação / Doutor em Engenharia Elétrica
6

Otimização de sequencias de estimulação eletrica neuromuscular para a restauração de movimentos dos membros superioresde tetraplegicos

Oberg, Telma Dagmar 10 October 1995 (has links)
Orientador: Alberto Cliquet Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-20T21:50:29Z (GMT). No. of bitstreams: 1 Oberg_TelmaDagmar_M.pdf: 12703408 bytes, checksum: f5a67ec927a30e9163465e8e998198cd (MD5) Previous issue date: 1995 / Resumo: Nas duas últimas décadas, a estimulação elétrica neuromuscular tem sido considerada um importante instrumento em muitas áreas da reabilitação. Para o tetraplégico ela tem sido usada, principalmente, na restauração de movimentos dos membros superiores que é prioridade em sua reabilitação. Neste estudo, um sistema de estimulação elétrica neuromuscular controlado por microcomputador foi aplicado nos membros superiores de dez pacientes tetraplégicos com níveis de lesão entre C4-C7 (lesões devido a trauma medular e com tempo de lesão entre um a vinte e oito anos), para conseguir controle funcional de preensão e liberação de objetos e orientação do membro no espaço. O sistema de estimulação consistiu de um estimulador neuromuscular multicanal controlado por um software desenvolvido em linguagem "C". O estímulo elétrico foi disparado através de eletrodos de superfície localizados no braço, objetivando o ponto motor do músculo selecionado. A seleção dos músculos baseou-se na análise eletromiográfica de sujeitos normais, na cinesiologia e nos testes de atividade motora voluntária e resposta ao estímulo elétrico. As seqüências de movimentos basearam-se em padrões de preensão cilíndrica, palmar e paralela em extensão, e liberação de objetos. Padrões de estimulações (até oito canais de estimulação) foram aplicados nos músculos para produzirem sinergismo de movimentos do punho e dedos pela contração dos músculos de cada articulação/segmento, objetivando: (i) abertura da mão, para aceitar o objeto; (ii) posição de função da mão; (iii) fechamento da mão; (iv) deslocamento do membro superior com flexão do cotovelo; (v) deslocamento do membro superior com extensão do cotovelo; (vi) abertura da mão, para a liberação do objeto; e (vii) relaxamento do membro superior. Os resultados demonstraram que oito pacientes foram aptos para segurar e liberar objetos que são necessários nas atividades da vida diária, como utensílios para comer, beber e instrumentos para escrever, através de movimentos próximos do fisiológico que dantes não podiam ser realizados. Assim, os testes clínicos foram satisfatórios na restauração dos movimentos dos membros superiores de tetraplégicos, permitindo programar e eleger as melhores seqüências de movimentos requeridas pela coordenação temporal da atividade muscular durante a preensão e liberação de objetos / Abstract: In the last two decades, neuromuscular electrical stimulation (NMES) has been considered an important too! in many areas of rehabilitation. For quadriplegics it has been used, mainly, in the restoration of upper limb movements which is a high priority in their rehabilitation. This work presents a microcomputer based neuromuscular stimulation system wich was applied to the upper limbs of ten patients with quadriplegia between C4-C7 levei (ali lesions due to spinal trauma and time of lesion between 1 and 30 years), to obtain functional control of grasp-release and orientation of !imb through space. The stimulation system consisted of a multichannel neuromuscular stimulator controlled by a software developed in "C" language. The electrical stimuli were delivered through bipolar surface electrodes placed on the arm surface, targeting the motor points of the selected muscles. The selection of the muscles was based on electromyographical analyses of normal subjects, kinesiology, muscle strength tests and electrical stimulation. The movement sequences were based on patterns of hand prehension and release (cylindrical grasp, palmar prehension and paralle! extension grip). Patterns of stimulation (up to four channels of stimulation) were applied to the muscles to produce synergism of movement of the wrist and fingers by contracting the flexor and extensor muscles of each articulation/segment, aiming at:(i) opening of hand (to accept objects); (ii) position of hand; (iii) closing of hand; (v) opening of hand (to release objects); and (vi) limb relaxation. As a result, eight patients have demonstrated the ability to hold and release objects that are encountered in daily living, Le, eating and drinking utensils, and writing instruments. The work has lead to successful clinical tests in restoration of upper limb movement to quadriplegics, thus allowing programming movement sequences required for temporal coordination (timing) of muscular activity during grasping/releasing / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
7

Eletroestimulação intravaginal no tratamento da dor pelvica cronica

Bernardes, Nicole de Oliveira 03 August 2018 (has links)
Orientador: Luis Guillermo Bahamondes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-03T17:14:55Z (GMT). No. of bitstreams: 1 Bernardes_NicoledeOliveira_M.pdf: 126800 bytes, checksum: d2a497f414ecf6f48752e5d5102cc180 (MD5) Previous issue date: 2003 / Resumo: Este estudo avaliou a eficácia da eletroestimulação intravaginal em mulheres com dor pélvica crônica. No período de maio de 2002 a junho de 2003 foram avaliadas 24 mulheres com DPC sem causa aparente na Seção de Fisioterapia do Centro de Atenção Integral à Saúde da Mulher da Universidade Estadual de Campinas, que foram submetidas a dez sessões de eletroterapia intravaginal. Foi utilizado o programa para dor crônica difusa com freqüência de 8Hz, com variação de intensidade e freqüência, largura de pulso de1mS e intensidade suportável para cada paciente (em mA). O tratamento foi realizado duas a três vezes por semana em aplicações de 30 minutos e a dor foi avaliada, através da escala análoga visual, antes e após cada sessão e imediatamente após o tratamento completo. As mulheres foram acompanhadas e questionadas sobre o escore de dor na segunda e quarta semanas seguintes ao final do tratamento. Os resultados mostraram que a eletroestimulação intravaginal foi efetiva no alívio da sintomatologia dolorosa em mulheres com DPC avaliadas imediatamente após o final do tratamento e na segunda e quarta semanas após o final do tratamento. A queixa de dispareunia apresentou redução significativa após o tratamento. Estes resultados mostram a eficácia da eletroestimulação intravaginal no alívio dos sintomas dolorosos em mulheres com dor pélvica crônica / Abstract: This study assessed the efficacy of intravaginal electrostimulation in women with chronic pelvic pain (CPP). During the period of May 2002 through June 2003 a total of 24 women with CPP and without apparent cause were evaluated at the Pshysical Therapy Section of CAISM/UNICAMP. They were submitted to 10 sessions of transvaginal electrostimulation. A program to difuse chronic pain was used with a frequency of 8Hz with na intensity variotion and pulse amplitude of 1mS and intensity according to each patient (in mA). The treatment was performed two to three times a week with applications of 30 minutes and the pain was assessed through the visual analogue scale (VAS) before and after each session and inmediatly after the end of the complete treatment. The women were asked about the pain score at the second and fourth weeks after the end of treatment. The results showed that the intravaginal electrostimulation was effective in the pain relief in women with CPP inmediatly after the end of treatment and at the second and fourth weeks after the end of treatment. Dispareunia was significantly reduced after the treatment. These results showed that intravaginal electrostimulation was effective in the control of pelvic pain among women / Mestrado / Tocoginecologia / Mestre em Tocoginecologia
8

Analise eletromiografica do musculo temporal no homem

Vitti, Mathias, 1938-2015 20 July 2018 (has links)
Orientador: Odorico Machado de Sousa / Tese (doutorado) - Universidade de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T13:13:05Z (GMT). No. of bitstreams: 1 Vitti_Mathias_D.pdf: 3005109 bytes, checksum: 841f08f580f19f486077de48d23244f4 (MD5) Previous issue date: 1968 / Resumo: Em individuos considerados normais com dentição completa e em indivíduos com ausência parcial e total de dentes, foi estudada a atividade eletromiográfica do m. temporal nas suas tres porções, anterior, posterior e média. Foram examinados 57 pacientes sendo 15 com dentição completa e normal (grupo I); 30 com dentição incompleta mas com suporte molar bilateral (grupo II) e 12 totalmente desdentados (grupo III) ¿Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital / Abstract: Not informed. / Doutorado / Doutor em Ciências
9

Redução da fadiga muscular sob estimulação eletrica neuro-muscular

Peixoto, Beatriz de Oliveira 19 October 1995 (has links)
Orientador: Alberto Chiquet Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-21T01:13:58Z (GMT). No. of bitstreams: 1 Peixoto_BeatrizdeOliveira_M.pdf: 11544072 bytes, checksum: fbedaab7e6f0b5676aea5c8be3131352 (MD5) Previous issue date: 1995 / Resumo: As pesquisas na área de reabilitação ( Departamento de Engenharia Biomédica -F.E.E. ) têm focalizado o desenvolvimento de sistemas, via estimulação elétrica neuromuscular ( E.E.N.M.), para viabilizar a locomoção de pacientes portadores de lesão medular. Uma limitação da E.E.N.M. é a fadiga muscular, que é manifestada quando um músculo diminui a força esperada ou requisitada durante a marcha. O propósito deste estudo foi examinar a possibilidade de estimular os sistemas de controle do músculo do quadríceps femoral através da E.E.N.M., em pacientes com lesão medular, a fim de aumentar a resistência à fadiga muscular. Foram investigadas, através do programa experimental, duas técnicas: E.E.N.M. com um canal de estimulação ( programa inicial) e E.E.N.M. multicanal sequencial (programa alternativo). Os parâmetros de estimulação aplicados foram: frequência de 25Hz com uma largura de pulso de 300us. e ciclo de trabalho de 33%. O efeito dos programas experimentais foram determinados pelos registros periódicos dos tempos das sessões ( ambos os programas) e número de contrações das sessões (programa inicial)... Observação: O resumo, na íntegra, poderá ser visulaizado no texto completo da tese digital / Abstract: Research in the area of rehabilitation (Biomedical Engineering Department - F.E.E.) has focused on the development of systems by neuromuscular electrical stimulation (N.M.E.S.), to allow it possible the locomotion of spinal cord patients. A limitation of N.M.E.S. is muscle fatigue which shows up when a muscle reduces the expected or required strength during gait. The goal of this study was to examine the possibility of stimulating the quadriceps muscle control systems by N.M.E.S. in patients with spinal cord injury with the purpose of increasing resistance to muscle fatigue. We investigated two techniques in the experimental programme : N.M.E.S. with one stimulation channel ( initial programme ) and N.M.E.S. with sequential multichannel ( altemative programme ). Stimulation parameters used : frequency of 25 Hz with a pulse duration of 300us. and duty cycle of 33%. The effect of the experimental programmes were detennined by the periodic recording of time sessions ( both programmes ) and contraction numbers of sessions ( initial programme)... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Mestre em Engenharia Elétrica
10

Variaveis associadas a determinação do limiar basal de resposta da polpa dental ao estimulo eletrico / Variables associated to pulpal threshold determination with electrical stimulus

Branco, Filipe Polese 28 February 2007 (has links)
Orientador: Maria Cristina Volpato / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T06:11:11Z (GMT). No. of bitstreams: 1 Branco_FilipePolese_D.pdf: 1567364 bytes, checksum: 49e978a109d02d28d81bb848765787cd (MD5) Previous issue date: 2007 / Resumo: O uso do pulp tester ainda não está padronizado na literatura. Assim, o objetivo deste trabalho foi determinar as condições ideais para determinação do limiar basal de resposta pulpar a estímulo elétrico. Duzentos e cinqüenta e seis voluntários sadios e com dentes responsíveis a estímulo elétrico foram selecionados e divididos em 7 estudos. Estímulo elétrico foi aplicado aos dentes em testes sucessivos, com intervalo de 2 minutos entre eles. As variáveis estudadas foram: número de medidas e de voluntários, necessidade de secagem do dente, influência da solução condutora, do operador, do período do dia e da temperatura ambiente, do grupo étnico-racial do voluntário, e do uso de ácido mefenâmico e nimesulida. Foi também avaliada a sensibilidade dolorosa dos voluntários por meio da escala analógica visual (EAV). Os resultados de limiar basal de resposta pulpar foram submetidos aos testes t e de Tukey e os de EAV aos testes de Wilcoxon e Friedman (a=0,05). A média obtida com 3 medidas não diferiu das obtidas com número maior de medidas; a secagem prévia do dente e o uso de gel de flúor neutro levaram a menores valores de limiar pulpar; voluntários de ambos os gêneros apresentam maiores valores de limiar pulpar quando avaliados por operador do gênero feminino. Não houve diferença no limiar pulpar entre os horários 8h, 11h, 14h e 17h, entre as sessões com temperatura ambiente inferior a 15oC ou superior a 25oC, bem como entre as raças amarela, branca e preta, e após administração de dose única de ácido mefenâmico ou de nimesulida quando comparados a placebo. Concluiu-se que para a determinação do limiar basal pulpar após aplicação de estímulo elétrico deve-se fazer a média de pelo menos 3 medidas consecutivas e utilizar no mínimo 20 voluntários; a secagem prévia do dente pode levar à melhor condução do impulso; o gel de flúor neutro deve ser a substância condutora de escolha; o gênero do operador pode exercer influência nos voluntários; o limiar basal pulpar não apresenta ritmo circadiano e não sofre interferência da temperatura ambiente, da etnia do voluntário ou da nimesulida e ácido mefenâmico, administrados em dose única / Abstract: There are some unclear aspects about electrical pulpal threshold measure. The objective of this study was to determine the ideal conditions for pulpal threshold measure. Two hundred and fifty six healthy volunteers with teeth able to respond to electrical stimulus were selected and divided in 7 studies. Pulpal threshold was evaluated by means of an electric pulp tester, with a 2min interval between tests. The variables studied were: number of measures and volunteers, and the influence of moisture, conductive media, gender of the operator, room temperature, period of the day, volunteers¿ ethnicity, and administration of mefenamic acid and nimesulide. Pain sensibility was evaluated by Analogue Visual Scale (VAS). Pulpal threshold data were evaluated by ANOVA and t and Tukey tests; VAS results were submitted to Wilcoxon and Friedman tests. Results: the mean obtained with 3 measures was not dfferent than the obtained with higher number of measures; lower pulpal threshold means were obtained with previous dryness of teeth and neutral fluoride gel as conductive media; male and female volunteers presented higher pulpal threshold mean when evaluated by female operator; no difference in pulpal threshold were observed among ethnic Brazilian groups, yellow, white, and black, among periods of the day (8h, 11h, 14h and 17h), between room temperature bellow 15oC and above 25oC and with the administration of mefenamic acid and nimesulid when compared to placebo. It was concluded that at least 20 volunteers must be measured and 3 measures must be performed to determine electrical pulpal threshold; dryness of teeth can improve electrical conductance; operator gender can influence the volunteers¿ pulpal threshold; pulpal threshold is not influenced by room temperature, volunteer ethnicity, and single dose dministration of mefenamic acid and nimesulide. No circadian pattern was observed for pulpal threshold / Doutorado / Farmacologia, Anestesiologia e Terapeutica / Doutor em Odontologia

Page generated in 0.0582 seconds