71

Avaliação das tensões e do destorque de parafusos : influência do desajuste marginal e dos tipos de metais em infraestruturas protéticas retidas por implantes / Stress distribution and screw detorque analysis: : influence of misfit and alloy types in cast implant retained frameworks

Tramontino-Mesquita, Vanessa Silva, 1982- 02 October 2012 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T17:02:54Z (GMT). No. of bitstreams: 1 Tramontino-Mesquita_VanessaSilva_D.pdf: 1263598 bytes, checksum: 21599a6e0153542032add63750d48770 (MD5) Previous issue date: 2012 / Resumo: O objetivo neste estudo foi avaliar a distribuição das tensões geradas aos implantes modificados, por meio de análise extensométrica e força de destorque dos parafusos de retenção protética, de acordo com o tipo de metal da infraestrutura (Titânio comercialmente puro - Ti c.p ou Cobalto-Cromo - Co-Cr) e presença ou ausência de desajuste vertical padronizado. Um modelo metálico foi confeccionado, simulando uma mandíbula edêntula. Cinco análogos de pilares multi-unit foram fixados ao modelo metálico, posicionados de forma a reter uma prótese fixa total sobre implantes. Dez infraestruturas em titânio c.p. e 10 infraestruturas em Co-Cr foram obtidas através de fundição em monobloco. Cada infraestrutura originou dois modelos para mensuração, um adaptado e outro desadaptado em relação aos análogos. Para a obtenção dos modelos desadaptados, anéis metálicos de espessuras conhecidas (100, 200 e 300 ?m) foram posicionados entre a infraestrutura e seus análogos correspondentes. As infraestruturas foram distribuídas entre os grupos de tratamento (n=10): G1: Titânio adaptada; G2: Titânio desadaptada; G3: Co-Cr adaptada; G4: Co-Cr desadaptada. Em todos os casos, as infraestruturas foram fixadas aos análogos com torque de 10 N.cm com torquímetro digital. A força de destorque foi avaliada com torquímetro digital e o desajuste vertical, avaliado por meio de microscópio óptico (aumento de 120x), pelo teste do parafuso único. Extensometria foi utilizada para determinar as tensões geradas às fixações. As médias e desvio padrão de desajuste (?m) foram G1: 36,63 (15,84), G2: 174,45 (33,64), G3: 43,25 (14,06) e G4: 173,18 (24,45) (ANOVA e Tukey; alfa=5%), havendo diferença entre adaptados e desajuste, porém sem diferença entre Ti e Co-Cr. Não houve diferença entre os metais para tensão induzida aos implantes, mas maiores valores de desajuste promoveram maior tensão (ANOVA e Tukey; alfa=5%). Houve forte correlação positiva entre desajuste e tensão (Coeficiente de Correlação de Pearson, r=0,7475 e p<0,0001) e moderada correlação positiva entre desajuste e destorque (Coeficiente de Correlação de Pearson, r=0,3357 e p=0,0341). Para tensão e destorque, houve fraca correlação positiva (Coeficiente de Correlação de Pearson, r=0,2146 e p=0,1834). Pode-se concluir que próteses desadaptadas, independentemente do tipo de liga, promovem aumento nos valores de tensão aos implantes, mas não influenciam na força de destorque de parafusos protéticos / Abstract: This study evaluated stress induced on the implants using strain gauges analysis, and detorque loads of titanium prosthetic screws according to the type of the framework metal (c.p. Titanium or Cobalt-Chromium) and to the presence or absence of misfit. A metallic master model was fabricated, simulating an edentulous patient mandible. Five multi-unit abutment analogues were fixed on the master model, placed as though they would support a total fixed prosthesis. Ten c.p. titanium and 10 cobalt-chromium frameworks were obtained by 1-piece casting. Each framework created 2 measurement models, one passive fitted and the other misfitted to the analogues. To obtain the misfitted measurement models, metallic rings with known thickness (100, 200 and 300 ?m) were positioned between the framework and its analogues. Frameworks were distributed to treatment groups (n=10): G1: Titanium Passive Fit; G2: Titanium Misfit; G3: Cobalt-Chromium Passive Fit; and G4: Cobalt-Chromium Misfit. All infrastructures were screwed to their analogues using a digital torquimeter, with a torque of 10 N.cm. Detorque was assessed with a digital torquimeter, and misfit was evaluated by an optical microscope (120 X) according to the one-screw test. Strain gauges were used to determine stress generated on the fixations. Misfit mean values (?m) were G1: 36.63 (15.84), G2: 174.45 (33.64), G3: 43.25 (14.06) e G4: 173.18 (24.45), presenting difference between passive fit and misfit however no difference was found between the metals (ANOVA and Tukey; alfa=5%). There was no difference between materials for stress induced upon implants, but a higher level of misfit promoted higher values of stress (ANOVA and Tukey; alfa=5%). There was a strong positive correlation between fit and stress (Pearson's Correlation Coefficient, r=0.7475 and p<0.0001), and a moderate correlation between fit and detorque (Pearson's Correlation Coefficient, r=0.3357 and p=0.0341). For stress and detorque, there was a weak positive correlation (Pearson's Correlation Coefficient, r=0.2146 and p=0.1834). Misfitted prostheses, regardless of the metal type, promote high rates of stress to the implants, but do not influence the detorque of prosthetic screws / Doutorado / Protese Dental / Doutor em Clínica Odontológica
72

Distribuição das tensões em regiões perimplantares em dois implantes comerciais (Ti e TiZr) de pequeno diâmetro: estudo fotoelástico / Distribution of stress in peri-implant regions in two commercial inplants (Ti and TiZr) small diameter: photoelastic study

Tatiana de Andrade Sabino 25 November 2014 (has links)
Objetivo: Avaliar a distribuição de tensões nas regiões periimplantares dos implantes de titânio (TiCP) e titânio- zircônio (TiZr), de pequeno diâmetro (3,3mm) e comprimento de 12mm, decorrentes de cargas axiais e oblíquas. Método: Foram confeccionados dois modelos fotoelásticos, sendo um com um implante de TiCP e o outro com um implante de titânio-zircônio (TiZr). Sobre os pilares de cicatrização foram aplicadas cargas axiais com angulações de 0, 10, 20 e 30, de 100N e 200N, em relação ao longo eixo do implante, por meio da máquina universal de ensaio conjugada ao polariscópio circular na configuração de campo escuro. As franjas isocromáticas foram analisadas nas regiões periimplantares, nas condições testadas. Resultados: Com angulações de 0 e 10, o implante de TiZr apresentou tensões menores em 80% das situações quando comparado com o implante de TiCP. Com angulação de 20, o TiZr apresentou tensões menores em 10% e com 30 de inclinação o TiZr apresentou tensões menores em 60% das áreas perirradiculares analisadas. Conclusões: O implante de TiZr apresentou tensões menores quando comparado com o TiCP na maioria das regiões avaliadas. / Objective: To evaluate the stress distribution in peri-implant regions of implants with pure titanium and titanium-zirconium (TiZr), small diameter (3.3mm) and a length of 12mm, resulting from axial and oblique loads. Method: Two photoelastic models were made, one with an implant TiCP and the other with an implant Titanium-Zirconium (TiZr) with 15% zirconium in its composition. On the healing abutments centered axial load and oblique 10, 20 and 30 (100N and 200N) to the long axis of the implant were applied by means of a universal testing machine coupled to the circular polariscope field configuration dark. The isochromatic fringes were analyzed in the peri-implant regions, in the tested conditions. Results: With angles of 0 and 10, the implant had lower stress TiZr in 80% of cases compared with the implant cpTi. With angle of 20, the TiZr had lower stress by 10% and with 30 tilt the TiZr had lower stress in 60% of periradicular areas analyzed. Conclusions: The presented implant TiZr showed lower stress compared to the rated cpTi in most regions.
73

The effect of a novel photoinitiator system (RAP) on dental resin composites' flexural strength, polymerization stress, and degree of conversion

Schaub, Kellie January 2009 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Objectives: A new technology has been introduced into the field of dental resin composites that professes to enhance light-curing efficiency. Rapid amplified photopolymerization (RAP) initiator technology has not yet been fully compared with resin composites with conventional initiators such as camphorquinone (CQ). The purpose of this study was to compare and contrast the effects of this novel technology (RAP) on properties of two light-cured resin composites. Flowable (EFQ) and microfilled (ESQ) experimental composites were fabricated and supplied from Tokuyama Dental with (w/RAP) and without RAP (w/o RAP). The flexural strength (MPa) and flexural modulus (MPa) were obtained using a three-point bending apparatus (Sintech Renew 1123, Instron Engineering Corp., Canton, MA). Polymerization stress curves were created using a tensometer (American Dental Association Health Foundation, NIST, Gaithersburg, MD) which were then used to calculate the maximum stress rate. Finally, the degree of conversion was measured using infrared spectroscopy (Jassco FT-IR spectrometer, Model: 4100, Jasco Corporation, Tokyo, Japan). When evaluating the flexural strength, the peak stress for EFQ w/RAP was significantly higher than EFQ w/o RAP (p = 0.0001). This was statistically not significant for the ESQ group, even though ESQ w/RAP did have a higher peak stress then ESQ w/o RAP (p = 0.28). The interaction between resin type and RAP was not significant when evaluating the flexural modulus (p = 0.21). Formulations with RAP had a significantly higher flexural modulus then w/o RAP (p = 0.0001). Experimental resins with RAP had significantly higher maximum stress rates than those w/o RAP when evaluating polymerization stress (p = 0.0001). Finally, groups w/ RAP appeared to have a higher degree of conversion than groups without (p = 0.0057). This study showed that the experimental composites with RAP had greater mechanical properties than those without. Unfortunately, the increase in polymerization stress causes concern clinically due to the chance of leakage at the restoration/tooth interface. One of the main potential disadvantages of this new RAP technology is an increase in the polymerization stress. Deciding if this amount of polymerization stress is clinically acceptable is yet to be accomplished.
74

Mechanical Properties Of Provisional Restorative Materials

Shimizu Oliva, Graciela, 1976- January 2010 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / A provisional restoration must fulfill biologic, mechanical, and esthetic requirements. These prostheses should provide comfort, pulp protection, positional stability, occlusal function, hygiene access, esthetics, strength and retention. Methyl-methacrylate acrylic has assumed many appli¬cations in the field of restorative dentistry. However, the material still has deficiencies, such as polymerization shrinkage, pulpal damage associated with exothermic polymerization and susceptibility to fracture. Bis-GMA composites, Bis-acryl composites and visible light-cured urethane dimethacrylate resins have been developed to address these issues. The purpose of this study was to compare the mechanical properties of provisional restorations made from composite resins (Protemp Plus, Luxatemp Solar, Radica, Protemp Crown) to those made of the traditional methacrylate resins (Jet, Snap, High Impact). Six groups of samples, two groups from methacrylate and four groups from composite based materials, were fabricated. Samples from each group were evaluated for microhardness (n=10), flexural strength and flexural modulus (n=20) according to ISO 4049, and fracture toughness (n=20) according to ISO 13586. From each of the six groups, ten samples were tested for flexural strength, flexural modulus and fracture toughness and 5 samples were tested for microhardness. These tests were done after storing at 37°C in a distilled water solution for 7 days followed by thermal cycling (2500 cycles, 5-55°C, 45 s. dwell). Identical sets of samples from each group were used as controls; these were tested after storing for 24 hours in dry conditions. The results were analyzed by two-way ANOVA with material type and aging conditions as the two main variables. Significance level was set at p=0.05. For flexural strength and flexural modules, the higher values were obtained for Radica. Protemp plus (7 days) and Radica (24h) had the highest fracture toughness value. Protemp crown showed the highest surface hardness. The mechanical properties of composite resin were superior.
75

Fracture resistance of porcelain-veneered gold-alloy and zirconia molar crowns

Nilsson, Eddie, Drazic, Marko January 2013 (has links)
AbstraktSyfte:Studiens syfte var att utreda maxlasttoleransen mellan yttria-stabiliserad zirkoniumdioxid- (Y-TZP) och metallkeramiska- (MC) molarkronor med en ny design på in vitro belastningsformen. En stålkula användes för att utöva last på kusparna istället för i fissuren för att framställa en sprickbildning liknande den som ses kliniskt. Materialochmetod:26 kronor tillverkades, varav 13 högädla MC och 13presintrade Y-TZP. 7 av MC göts av 50% tidigare icke-gjuten och 50% omgjuten legering medan de kvarvarande 6 göts av 100% tidigare icke gjuten legering. Kronorna täcktes av ett fasadporslinoch cementerades på stansar av ett resinmaterial. Av de 26 kronorna genomgick 24 förbelastingstester och belastades slutligen till fraktur. Resultat: MC klarade signifikant högre belastningar än Y-TZP, P>0,001. Frakturerna skiljde sig också grupperna emellan där MC-gruppen uppvisade enbart adhesiva frakturer av fasadporslinet under det att Y-TZP-gruppen uppvisade kohesiva brott i ytporslinet undantaget en Y-TZP-krona som uppvisade total fraktur. Ingen signifikant skillnad kunde ses mellan MC-kronor bestående av enbart tidigare icke gjuten legering och MC-kronor med 50% omgjuten legering, P=0,370. Konklusion: MC-kronor klararsignifikant högre belastningar än Y-TZP-kronor och testet genererar kliniskt relevanta frakturer av ytporslinet snarare än totala frakturer. Frakturbeteendet skiljer sig mellan MC och Y-TZP där MC uppvisar endast adhesiva fraktureroch Y-TZP främst kohesiva brott av ytporslinet.
76

Avaliação de overdentures mandibulares com diferentes sistemas de retenção: análise fotoelástica da transmissão de tensões e efeito de carga cíclica na força de retenção / Evaluation of mandibular overdentures with different attachments systems: Photoelastic stress analysis and effect of cyclic loading on retention force

Aguiar Junior, Fábio Afrânio de 01 July 2013 (has links)
O surgimento dos implantes osseointegrados melhorou a qualidade de vida de pacientes edêntulos. Seu uso favorece retenção e estabilidade, gerando maior eficiência mastigatória e conforto. O objetivo deste estudo foi avaliar manutenção da força de retenção e padrões de tensões gerados na mandíbula em overdentures confeccionadas com dois sistemas de retenção retidas por 2 ou 3 implantes. Teste de carga cíclica e análise fotoelástica de tensões foram realizados. Para o teste de carga cíclica foram utilizados modelos representativos de mandíbulas desdentadas e os grupos analisados foram: A) 2 implantes com barra clipe; B) 3 implantes com barra clipe; C) 2 implantes com barra clipe e bola/o\'ring nas extremidades; D) 3 implantes com barra clipe e bola/o\'ring nas extremidades. Cinco espécimes por grupo foram submetidos à ciclagem e 5 permaneceram imersos na máquina de ciclagem (controle). As leituras de força de retenção foram realizadas por ensaio de tração em máquina de ensaios universal antes da ciclagem e a cada 500 mil ciclos. A ciclagem foi realizada com frequência de 1,8 Hz, carga de 130 N, por 2 milhões de ciclos. Para a aplicação de carga, foram feitas pontas correspondentes à arcada antagonista unilateral posterior. Os dados obtidos foram analisados estatisticamente pelo modelo linear de efeitos mistos. Para a análise fotoelástica, foi feito um modelo mestre curvo em resina acrílica. O modelo foi preparado para conter cinco implantes, paralelos, distribuídos na região interforaminal. Grupo com 4 implantes com barra clipe e o\'rings nas extremidades foi incluído como controle. Prótese total foi confeccionada e usada em todos os grupos. A cada grupo, nova captura de retentores foi realizada. Para obtenção dos modelos fotoelásticos, foram confeccionados moldes em silicone do modelo mestre. A verificação das tensões em torno dos implantes foi realizada por meio de análise fotoelástica qualitativa de transmissão sob aplicação de carga cêntrica estática de 50 N. Diferentes tipos de pontas e locais de aplicação de carga foram usados. Os resultados demonstraram que carga cíclica influencia na perda de retenção overdentures mandibulares. Comparando grupos controle e teste, observou-se que os grupos com três implantes apresentaram maior influência da ciclagem na perda de retenção. Os sistemas de retenção estudados apresentaram comportamentos diferentes até um milhão de ciclos, após não houve diferença quanto à manutenção de retenção. Todos os grupos mantiveram retenção satisfatória ao final da ciclagem. Três implantes apresentaram maior tensão ao redor dos implantes e pouca ou nenhuma sobre o rebordo. Nos grupos com dois implantes, aplicação de carga posterior gerou tensões no rebordo alveolar e implantes. Grupos com extensões distais evidenciaram uma maior tensão ao redor dos implantes que os sem extensão. / The appearance of osseointegrated dental implants improved the quality of life of fully edentulous patients. Implants promote retention and stability, producing higher masticatory efficiency and comfort. The aim of this study was analyze the retention maintenance and the stress pattern generated by two or three implants-supported mandibular overdentures with two attachments systems. Cyclic loading test and photoelastic stress analysis were performed. For the cyclic loading test, edentulous mandibular models were used. The analyzed groups were: A) 2 implants with bar clip; B) 3 implants with bar clip; C) 2 implants with bar clip and balls/o\'rings in the extremity; D) 3 implants with bar clip and balls/o\'rings in the extremity. Five specimens per group were submitted to cyclic loading and five were kept immersed inside the test machine (control group). The measurements of retention force were performed by tensile test in a universal testing machine before cyclic loading and after each 500 thousands cycles. The cycling was performed with frequency of 1.8 Hz, loading of 130 N, up to two million cycles. For the load application, tips corresponding to posterior unilateral antagonist teeth were produced. Data were statistically analyzed by linear mixed-effects model. For the photoelastic analysis, a curved master model was produced in acrylic resin. The model contained five parallel implants, distributed in interforaminal area. A group with 4 implants splinted with bar clip and balls/o\'rings in the extremity was included as a control. Complete denture was made and used in all groups. In each group, incorporating of new attachments was performed. For the obtainment of photoelastic models, silicone impression of the master model was performed. The assessment of stress around implants was done through quantitative transmission photoelastic analysis under static centric load application of 50 N. Different sorts of tips and load application places were used. The results showed that cyclic load influences the retention loss of mandibular overdentures. Comparing test and control groups, it was observed that groups with three implants showed higher influence of cyclic loading in retention loss. The studied attachments systems showed different behaviors up to one million cycles, after that there was not difference in the maintenance of retention. All groups had satisfactory retention at the end of cycling. Groups with three implants showed higher stress around implants and lower or none on alveolar ridge. In groups with two implants, load application on posterior area caused stress on alveolar ridge and implants. Groups with distal extensions demonstrated higher stress around implants than groups without extension.
77

Avaliação do nível de inserção óssea do dente suporte em prótese parcial removível mandibular classe I associada a implante osseointegrado: análise pelo método dos elementos finitos

Verri, Fellippo Ramos [UNESP] 11 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-11Bitstream added on 2014-06-13T19:44:51Z : No. of bitstreams: 1 verri_fr_dr_araca.pdf: 1853726 bytes, checksum: 578403c1602d78c980bb821e076ea43c (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A colocação de PPR de extremidade livre no arco inferior é uma das mais complexas dentro da área protética. A associação desta com implantes na região distal tem melhorado biomecanicamente seu funcionamento. Porém, existem poucos estudos a respeito desta associação levando em consideração o nível de inserção óssea do dente suporte. Assim, o objetivo desta pesquisa foi avaliar, por meio do método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte de uma PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), próximo ao dente suporte, com diferentes níveis de inserção óssea (íntegro e 1/2 da raiz) e com diferentes tipos de conexão entre a PPR e o dente suporte (apoio incisal e placa distal). Para o estudo, foram confeccionados 8 modelos mandibulares, de extremo livre, com a presença apenas do dente 33, sendo: MA - PPREL convencional, apoio incisal distal, inserção íntegra; MB - idem ao MA, mas utilizando placa distal; MC - idem ao MA, com implante de 3,75 x 10,0 mm e sistema ERA associado; MD - idem ao MC, mas utilizando placa distal; ME - idem ao MA, mas com perda de inserção de 1/2 da raiz; MF - idem ao MB, mas com perda de inserção de 1/2 da raiz; MG - idem ao MC, mas com perda de inserção de 1/2 da raiz; MH - idem ao MD, mas com perda de inserção de 1/2 da raiz. Com o auxilio do programa ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N em cada ponta de cúspide. Os resultados foram obtidos pelos mapas de deslocamento e de tensão de von Mises e mostraram que o implante favorece a associação da forma descrita, que a placa possibilita um maior alívio e menor deslocamento do dente suporte, e que a perda do periodonto de suporte prejudica o prognóstico da prótese. / The rehabilitation with distal extension RPDA is very complex in the prosthetic area and the association with implants had improving its work biomechanical. However, there is little studies about this type of association and no study about the lost of insertion was encountered by FEA. So, the aim of this study was to evaluate, by FEA 2-D, the tension distribution in support structures of a DERPD associated with a osseointegrated implant of 10,0 x 3,75 mm (Branemark System), near to support tooth, with different levels of bone insertion (no lost and 1/2 of root) and with different type of connection between the DERPD and de support tooth (incisal rest and distal plate). For the study, 8 distal extension mandibular models were made, with the presence of tooth 33, presenting: MA - conventional DERPD, incisal rest, no bone lost; MB - like MA, but with distal plate; MC - like MA, but with implanto of 3,75 x 10,0 mm and ERA system associated; MD - like MC, but with distal plate; ME - like MA, but with bone lost of 1/2 of root; MF - like MB, but with bone lost of 1/2 of root; MG - like MC, but with bone lost of 1/2 of root; MH - like MD, but with bone lost of 1/2 of root. By mean of program of FEA ANSYS 9.0, the models were carried with axial forces of 50 N in each cusp tip. The results were obtained by dislodgement maps and von Mises tension maps and shown that the implant was benefit to association by the study, and the plate decreased the tension and the dislodgement of the support tooth, and the bone lost was prejudicial to prognostic of this type of prosthesis. By this methodology, was possible to conclude that: the introduction of an osseointegrated implant with ERA system used like this study decrease the dislodgement of above structures in all models.
78

Avaliação de overdentures mandibulares com diferentes sistemas de retenção: análise fotoelástica da transmissão de tensões e efeito de carga cíclica na força de retenção / Evaluation of mandibular overdentures with different attachments systems: Photoelastic stress analysis and effect of cyclic loading on retention force

Fábio Afrânio de Aguiar Junior 01 July 2013 (has links)
O surgimento dos implantes osseointegrados melhorou a qualidade de vida de pacientes edêntulos. Seu uso favorece retenção e estabilidade, gerando maior eficiência mastigatória e conforto. O objetivo deste estudo foi avaliar manutenção da força de retenção e padrões de tensões gerados na mandíbula em overdentures confeccionadas com dois sistemas de retenção retidas por 2 ou 3 implantes. Teste de carga cíclica e análise fotoelástica de tensões foram realizados. Para o teste de carga cíclica foram utilizados modelos representativos de mandíbulas desdentadas e os grupos analisados foram: A) 2 implantes com barra clipe; B) 3 implantes com barra clipe; C) 2 implantes com barra clipe e bola/o\'ring nas extremidades; D) 3 implantes com barra clipe e bola/o\'ring nas extremidades. Cinco espécimes por grupo foram submetidos à ciclagem e 5 permaneceram imersos na máquina de ciclagem (controle). As leituras de força de retenção foram realizadas por ensaio de tração em máquina de ensaios universal antes da ciclagem e a cada 500 mil ciclos. A ciclagem foi realizada com frequência de 1,8 Hz, carga de 130 N, por 2 milhões de ciclos. Para a aplicação de carga, foram feitas pontas correspondentes à arcada antagonista unilateral posterior. Os dados obtidos foram analisados estatisticamente pelo modelo linear de efeitos mistos. Para a análise fotoelástica, foi feito um modelo mestre curvo em resina acrílica. O modelo foi preparado para conter cinco implantes, paralelos, distribuídos na região interforaminal. Grupo com 4 implantes com barra clipe e o\'rings nas extremidades foi incluído como controle. Prótese total foi confeccionada e usada em todos os grupos. A cada grupo, nova captura de retentores foi realizada. Para obtenção dos modelos fotoelásticos, foram confeccionados moldes em silicone do modelo mestre. A verificação das tensões em torno dos implantes foi realizada por meio de análise fotoelástica qualitativa de transmissão sob aplicação de carga cêntrica estática de 50 N. Diferentes tipos de pontas e locais de aplicação de carga foram usados. Os resultados demonstraram que carga cíclica influencia na perda de retenção overdentures mandibulares. Comparando grupos controle e teste, observou-se que os grupos com três implantes apresentaram maior influência da ciclagem na perda de retenção. Os sistemas de retenção estudados apresentaram comportamentos diferentes até um milhão de ciclos, após não houve diferença quanto à manutenção de retenção. Todos os grupos mantiveram retenção satisfatória ao final da ciclagem. Três implantes apresentaram maior tensão ao redor dos implantes e pouca ou nenhuma sobre o rebordo. Nos grupos com dois implantes, aplicação de carga posterior gerou tensões no rebordo alveolar e implantes. Grupos com extensões distais evidenciaram uma maior tensão ao redor dos implantes que os sem extensão. / The appearance of osseointegrated dental implants improved the quality of life of fully edentulous patients. Implants promote retention and stability, producing higher masticatory efficiency and comfort. The aim of this study was analyze the retention maintenance and the stress pattern generated by two or three implants-supported mandibular overdentures with two attachments systems. Cyclic loading test and photoelastic stress analysis were performed. For the cyclic loading test, edentulous mandibular models were used. The analyzed groups were: A) 2 implants with bar clip; B) 3 implants with bar clip; C) 2 implants with bar clip and balls/o\'rings in the extremity; D) 3 implants with bar clip and balls/o\'rings in the extremity. Five specimens per group were submitted to cyclic loading and five were kept immersed inside the test machine (control group). The measurements of retention force were performed by tensile test in a universal testing machine before cyclic loading and after each 500 thousands cycles. The cycling was performed with frequency of 1.8 Hz, loading of 130 N, up to two million cycles. For the load application, tips corresponding to posterior unilateral antagonist teeth were produced. Data were statistically analyzed by linear mixed-effects model. For the photoelastic analysis, a curved master model was produced in acrylic resin. The model contained five parallel implants, distributed in interforaminal area. A group with 4 implants splinted with bar clip and balls/o\'rings in the extremity was included as a control. Complete denture was made and used in all groups. In each group, incorporating of new attachments was performed. For the obtainment of photoelastic models, silicone impression of the master model was performed. The assessment of stress around implants was done through quantitative transmission photoelastic analysis under static centric load application of 50 N. Different sorts of tips and load application places were used. The results showed that cyclic load influences the retention loss of mandibular overdentures. Comparing test and control groups, it was observed that groups with three implants showed higher influence of cyclic loading in retention loss. The studied attachments systems showed different behaviors up to one million cycles, after that there was not difference in the maintenance of retention. All groups had satisfactory retention at the end of cycling. Groups with three implants showed higher stress around implants and lower or none on alveolar ridge. In groups with two implants, load application on posterior area caused stress on alveolar ridge and implants. Groups with distal extensions demonstrated higher stress around implants than groups without extension.
79

Biodinamica restauradora de dentes tratados endodonticamente : analise por elementos finitos / Restorative biomechanical of endodontic treated teeth : finite element analysis

Santos Filho, Paulo Cesar de Freitas 04 June 2009 (has links)
Orientador: Luis Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T11:40:25Z (GMT). No. of bitstreams: 1 SantosFilho_PauloCesardeFreitas_D.pdf: 10660151 bytes, checksum: bd3f67697b369623400074dcf22ec01c (MD5) Previous issue date: 2009 / Resumo: O objetivo deste estudo foi desenvolver protocolo de modelagem tridimensional para incisivo central superior com aplicabilidade ao método de elementos finitos e avaliar o comportamento biomecânico de incisivo superior tratado endodonticamente e restaurado com retentores e coroa cerâmica por meio de análise por elementos finitos comparado ao dente hígido. Para geração do modelo 3D foi selecionado incisivo central superior hígido. Esmalte e dentina foram degradados em diferentes fases com ácido clorídrico-10%, e mapeados com scanner de contato 3D (Modela, Roland). Para o mapeamento do volume pulpar, a dentina foi seccionada longitudinalmente no sentido mesio-distal e realizado o escaneamento do espaço negativo referente à polpa. Os arquivos *.STL foram exportados para programa Bio-CAD (Rhinoceros-3D). Volumes de cada estrutura dental e técnicas restauradoras foram gerados por meio da associação de superfícies NURBS. Os modelos foram exportados para o programa de elementos finitos (FEMAP-NeiNastran), onde foi realizado o processo de malhagem, inserção das propriedades mecânicas e condições de contorno. Foram gerados 17 modelos, sendo um do dente hígido e 16 modelos de acordo com os 4 fatores em estudo: tipo de retentor em dois níveis: pino de fibra de vidro (PFV) e núcleo moldado fundido (NMF), extensão do retentor em dois níveis: 7,0mm (7,0) e 12,0mm (12,0), remanescente coronário em dois níveis: remanescente de 2,0mm (RE) e ausência de remanescente (ARE), enfraquecimento do canal radicular em dois níveis: ausência de enfraquecimento (AENF) e presença de enfraquecimento (ENF). Foi simulada aplicação de pressão constante no valor de 100N perpendicularmente à superfície palatina do incisivo. Os resultados foram analisados pelo critério de von Mises e tensão máxima principal. Os resultados obtidos mostraram que o modelo geométrico 3D desenvolvido é adequado para a análise por elementos finitos. Concluiu-se que o PFV apresenta distribuição homogênea das tensões mais semelhante ao dente hígido, enquanto o NMF apresentou grande concentração de tensão no interior do canal radicular. O fator extensão do retentor intra-radicular influenciou isoladamente apenas a distribuição de tensões do NMF. A presença de remanescente coronário sempre melhorou a distribuição de tensões. O enfraquecimento do canal radicular teve maior impacto na distribuição de tensões. / Abstract: The aim of this study was develop 3D model generation protocol for upper anterior teeth for finite element analysis and evaluate biomechanical behavior of endodontically treated incisor with finite element analysis compared to sound teeth. It was selected intact upper central incisor. Enamel and dentin were treated in different steps with cloridric acid 2% and scanned with 3D-contact scanner. The stereolithographics archives were exported to Bio CAD program. The volums of each dental structure and restorative techniques were generated by association of NURBS surfaces. The models were exported for finite element software, where were realized the meshed process, mechanical properties insertion and bondary conditions. It were generated 17 models, one was a sound incisor model and 16 models according to 4 studied factors: post type: glass fiber post (GFP) and cast post and core (CPC), post length: 7,0mm (7,0) e 12,0mm (12,0), ferrule: 2,0mm ferrule (FE) and absence of ferrule (AFE), weakness of root canal: absence of weakness (AWR) and weakened root (WR). It was simulated 100N loading application on the palatal surface with 135° angulation. The results were analised by Von Mises criteria and principal maximum tension. Obtained results showed that geometric model developed is appropriated for finite element analysis. It can be concluded that GFP showed homogeneous stress distribution like the sound incisor, while CPC showed stress concentration into root canal. The post length influenced only the CPC stress distribution. The ferrule always showed better stress distribution. The weakness of root showed the highest impact in stress distribution. / Doutorado / Dentística / Doutor em Clínica Odontológica
80

Efeito do tipo de pino, altura do remanescente coronário e carregamento na distribuição de tensões em prótese fixa de três elementos / Effect of post, ferule presence and loading on stress distribution in 3-unit fixed parcial denture

Silva, Gisele Rodrigues da, 1982- 12 July 2012 (has links)
Orientador: Luís Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T16:51:03Z (GMT). No. of bitstreams: 1 Silva_GiseleRodriguesda_D.pdf: 2969310 bytes, checksum: 065fbdffc0e741bd55d3cb562acde2e8 (MD5) Previous issue date: 2012 / Resumo: O objetivo deste estudo foi investigar a influência do retentor intrarradicular, altura do remanescente coronário e tipo de carregamento virtualmente simulado, no comportamento biomecânico de prótese fixa anterior de 3 elementos. Quatro modelos tridimensionais de elementos finitos foram criados comparando-se o tipo de retentor nos dentes pilares (fibra de vidro ou núcleo metálico fundido) e a altura do remanescente coronário (0 e 2 mm). Para simular o tipo de carregamento foram considerados dois níveis de aplicação da força: 1- simulação de contato protrusivo (PRT): 200 N distribuídos nas cristas marginais palatinas dos incisivos superiores, sendo 50 N em cada crista marginal, a 45o do longo eixo do dente e 2- simulação de contato em lateralidade canina (LAT): 200 N aplicados na palatina do canino a 15º. Todos os materiais foram considerados homogêneos, lineares, elásticos e isotrópicos com exceção do pino de fibra de vidro, que foi considerado transversalmente isotrópico. O problema estrutural foi solucionado computacionalmente pelo Método de Elementos Finitos (MEF), em análise estrutural estática. A coerência da simulação foi observada pela análise do deslocamento e pelas tensões de von Mises. O deslocamento foi analisado de forma qualitativa e quantitativa comparando-se a região de deslocamento máximo sofrido pela prótese. Em seguida, foram comparadas as tensões máximas principais ocorridas na região de conexão entre pôntico e dentes pilares, na raiz do incisivo central, do canino e nas interfaces pino-dentina radicular e núcleo de preenchimento-dentina. Concluiu-se que as tensões de tração são concentradas entre pôntico/ pilar e na palatina dos dentes pilares da prótese fixa anterior. Sendo que a protrusão gera maior concentração de tensão máxima principal de tração nos dentes pilares e gera deslocamento duas vezes maior do que a lateralidade. Ademais, a presença de remanescente coronário melhora a distribuição das tensões e o pino de fibra de vidro mostrou-se adequado em prótese fixa anterior de 3 elementos / Abstract: The aim of this study was to investigate the influence of post, load condition and ferule presence in abutment teeth on the stress distribution in the anterior three-unit fixed dental prosthesis (FDP) made of lithium dissilicate. Four three-dimensional finite element (FE) models were created comparing the type of post using on the abutment teeth in two levels (fiberglass post and cast post-and-core) and the coronal remaining in two levels (with or without ferule presence). Two load conditions were applied: 1- 200 N was distributed on palatine marginal ridge of incisive, with 50 N in each ridge, under a 45o angle with the long axis of the tooth, simulating the protrusive contact or 2- 200N was applied on palatine of canine at 15o. All materials were considered homogeneous, linear elastic, and isotropic, with the exception of the glass fiber post, which was considered transversally isotropic. Analysis by Finite Elements Method (FEM), was performed structural analysis. The displacement and Von Mises stress was applied to analyze the coherence o simulation. The displacement was analyzed by quality and quantity resuts in region of maximum prostheses displacement. Maximum principal stress was used as a criterion to compare the study factors. The stress distribution was compared in a descriptive way in the area of the connector, along the interface post/dentin and core/dentin and on abutment dentin teeth. In conclusion, the highest tensile stress was observed in the connector areas and on palatine abutments roots surfaces. The protrusion causes higher stress and displacement than canine guide. The ferrule presence in the abutment teeth reduced the maximum principal tensile stresses on tooth-restoration complex and the fiberglass post seems to improve the stress distribution on anterior 3-unit fixed-dental prostheses / Doutorado / Dentística / Doutora em Clínica Odontológica