• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 92
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • Tagged with
  • 92
  • 92
  • 25
  • 25
  • 17
  • 17
  • 14
  • 11
  • 11
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Estudo comparativo entre tecnicas radiograficas convencionais e digitais na analise dos niveis osseos alveolares

Gonçalves, Marcelo 21 August 2000 (has links)
Orientador: Francisco Haiter Neto / Tese (doutorado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T04:42:16Z (GMT). No. of bitstreams: 1 Goncalves_Marcelo_D.pdf: 4869640 bytes, checksum: c493d9125042cf2635d24e8a92cd4c5e (MD5) Previous issue date: 2000 / Resumo: A periodontia é o ramo da Odontologia direcionada ao diagnóstico e tratamento das estruturas de suporte dos dentes. A avaliação do osso e dos níveis de inserção clínica tem tradicionalmente contado com métodos físicos incluindo a sondagem periodontal e radiografias para avaliação da perda óssea. O objetivo desse trabalho foi comparar até que ponto a radiografia digital e digitalizada pode contribuir para a superação das limitações dos exames radiográficos tradicionais (periapical e interproximal) na determinação das mensuraçóes dos níveis ósseos alveolares das cristas interdentárias. Foi proposto, também, realizar uma análise comparativa das aparências radiográficas convencionais e digitalizadas das superfícies vestibulares e linguais/palatinas das cristas ósseas alveolares com o emprego da tomografia linear em cortes transversais dos maxilares, comparando as com as mensurações cirúrgicas. Para todas as incidências radiográficas foi utilizada uma placa oclusal com artefatos radiopacos que permitiam a comparação das mensurações cirúrgicas e radiográficas. Concluiu-se que, num âmbito geral, todas as técnicas intrabucais convencionais, digitais diretas e digitalizadas, e as tomografias convencional e digitalizada subestimaram os valores clínicos dos níveis ósseos alveolares. As mensurações com as técnicas radiográficas intrabucais foram de maior precisão nas faces distais dos elementos dentários anteriores e posteriores de ambas as arcadas / Abstract: The periodontology is an area of the dentistry addressed to the treatment of the teeth support structures. The evaluation of the bone and the union tissue have been traditionally noticed with physical methods including the periodontal probing and radiographic exam for bony loss. The objective of this study was to verify to what extent the digital and digitalized radiographies can contribute to overcome the limitations of the traditional radiography (periapical and interproximal) in the measurement determination of the alveolar proximal bony leveI. Also, it was intend to accomplish a comparative analysis of the conventional and digitalized radiography appearances of the facial and lingual surfaces of the alveolar bony crests, using cross linear tomography slices of the maxillaries, comparing them with the clinical measurement. It was concluded that ali the conventional, digital and digitalized intraoral radiographies, and conventional and digitalized tomographies underestimated the clinical values of bony leveI. The bone levei measurements using intraoral techniques showed larger precision to anterior and posterior teeth's distal surfaces / Doutorado / Doutor em Radiologia Odontológica
52

Tomografia convencional : estudo comparativo de imagens pre-operatorias para implantes dentais osteointegrados

Carneiro Junior, Elcio Gomes 12 July 2000 (has links)
Orientador: Agenor Montebello Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T10:40:05Z (GMT). No. of bitstreams: 1 CarneiroJunior_ElcioGomes_M.pdf: 3945591 bytes, checksum: a8f116e7440c15a9575a3582bbb89cae (MD5) Previous issue date: 2001 / Resumo: Os implantes osteointegrados tem sido cada vez mais utilizados para a reabilitação bucal de pacientes desdentados totais e parciais. O exame radiográfico é um exame auxiliar de fundamental importância, auxiliando desde o planejamento pré-operatório para colocação de implantes à proservação. A literatura mundial indica a utilização da Tomografia Convencional como exame pré-operatório para pacientes candidatos à receber poucos implantes ou implantes únicos. Este método radiográfico devido à própria técnica resulta em imagens ampliadas. Contudo, existem poucos relatos que demonstrem com clareza a importância da determinação da ampliação correta dos aparelhos de Tomografia Convencional e o resultado que esta ampliação pode representar no resultado final das medidas realizadas nas imagens destes exames. Neste trabalho utilizamos a técnica tomográfica convencional em oito regiões totalmente desdentadas de sete crânios humanos secos. Realizamos cortes tomográficos convencionais perpendiculares ao contorno do arco utilizando os aparelhos: Quint Sectograph, Orthopantomograph OP100 e o Planmeca 2002 CC Proline. As imagens foram medidas e comparadas com os valores anatõmicos. Os dados foram submetidos à análise estatística e demonstraram que quando os valores reais foram comparados com os valores radiográficos, as médias das medidas obtidas no aparelho Quint apresentaram uma tendência a se aproximar dos valores reais. Os valores obtidos dos aparelhos OP 100 e PM2002 diferiram do aparelho Quint, resultando valores métricos superiores aos valores reais. Quando da comparação dos valores reais com os valores radiográficos descontados da ampliação sugerida pelo fabricante, as médias das medidas obtidas no aparelho Quint, OP 100 e PM2002 diferiram dos valores reais, resultando valores métricos inferiores aos valores anatõmicos. Quando comparados os valores reais, com os valores radiográficos, descontados a ampliação obtida pela imagem dos guias radiográficos, as médias das medidas obtidas no aparelho Quint, OP 100 e PM2002 aproximaram dos valores reais, resultando valores métricos similares aos valores anatõmicos / Abstract: The intraosseous implants have been used more and more for oral rehabilitation in edentulous patients. The radiographic exam is a very important auxiliary in the preoperative implant procedure planning, evaluating with precision the morphological characteristics and dimensions of the alveolus in the implantation area. The literature indicates the utilization of the Conventional Tomography as a presurgical exam for the patients, but this exam provide augment images. However, there are few reports which clearly demonstrates the importance of the correct determination of the augment in Conventional Tomography units and the consequences of this augment can represent to the final result of the images measures. In this work, we used the Conventional Tomography technique in eight totally edentolous regions of seven dry human skulls. Were made slices perpendiculars to the arch contour using the units: Quint Sectograph, Orthopantomograph OP100 and the Planmeca 2002 CC Proline. The images were measured and compared with the anatomic values. The data were statistically processed and showed that when the real values were compared with the radiographic values, the average of the measures obtained with the Quint unit presented a tendency in approximate to the real values. The values obtained with OP 100 and PM2002 were different comparing with the Quint unit, resulting in higher metric values than the real values. When comparing the real values with the radiographic values discounting the augment suggested by the manufacturers, the average of the measures obtained with Quint, OP 100 and PM 2002 resulted in lower metric values compared with the anatomic values. When compared the real values with the radiographic values discounted of the augment obtained by the image of the guidance, the averages of the measures obtained with Quint, OP 100 and PM2002 were similar to anatomic values / Mestrado / Mestre em Radiologia Odontológica
53

Mensurações verticais para planejamento de mini-implantes palatinos em telerradiografia em norma lateral e tomografia computadorizada de feixe cônico / Vertical measurements for planning palatal mini-implants in lateral radiograph and cone beam computed tomography

Barbosa, Gabriella Lopes de Rezende, 1988- 20 August 2018 (has links)
Orientador: Solange Maria de Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T06:56:36Z (GMT). No. of bitstreams: 1 Barbosa_GabriellaLopesdeRezende_M.pdf: 1476954 bytes, checksum: 655317fdf41b3d0e2548c438c0fe7358 (MD5) Previous issue date: 2012 / Resumo: Os objetivos deste estudo foram comparar as mensurações lineares referentes à altura óssea palatina na região de primeiros pré-molares superiores para inserção de miniimplantes palatinos por meio de imagens de telerradiografia em norma lateral (TNL), tomografia computadorizada de feixe cônico (TCFC) e telerradiografia reconstruída do exame tomográfico (telerradiografia virtual); assim como comparar as alturas ósseas das regiões medianas e paramedianas do sítio avaliado. Para tanto, foram utilizadas 110 imagens de TNL, telerradiografia virtual e TCFC, dos mesmos pacientes. Para avaliação das alturas nas imagens, foi realizada mensuração da distância entre a intersecção do longo eixo do primeiro pré-molar com o assoalho do palato duro e o assoalho nasal, a qual correspondeu à dimensão do osso disponível para inserção de mini-implantes de ancoragem. Para avaliação das alturas medianas e paramedianas no corte tomográfico na região de primeiro pré-molar, foram realizadas mensurações da distância entre a camada cortical do assoalho nasal e a cortical do palato duro nos sítios central, 3 mm à direita e à esquerda, 6 mm à direita e à esquerda. As mensurações foram realizadas por três avaliadores. Os valores encontrados da TNL não diferiram estatisticamente (p>0,05) da TCFC (padrão-ouro), sendo comparáveis aos do exame tomográfico. Já os valores da telerradiografia virtual diferiram estatisticamente (p<0,05) tanto da TCFC quanto da TNL, sendo medidas subestimadas quando comparadas ao padrão-ouro e à técnica radiográfica. Quando comparadas as medidas dos sítios avaliados, não houve diferença estatística (p>0,05) entre as alturas paramedianas e a central. Concluiu-se que as mensurações realizadas para planejamento de inserções de mini-implantes palatinos na região dos primeiros prémolares são comparáveis nos exames de TNL e em reconstruções multiplanares de TCFC, e subestimadas nos exames de telerradiografia virtual. Concluiu-se também que as regiões paramedianas bilaterais a 3mm e 6mm da sutura palatina na região avaliada possuem altura óssea comparável à região mediana do palato / Abstract: The aims of this study were to compare linear measurements related to the palatal bone thickness in the region of first premolars to insert palatal mini-implants on images of conventional lateral radiography (CLR), cone beam computed tomography (CBCT) and reconstructed radiography from CBCT scan (virtual radiograph), as well as compare the thickness of the bone regions of the median and paramedian site assessed. For this purpose, 110 images of CLR, virtual radiography and CBCT of the same patient were used. To evaluate the thicknesses on the images, measurements was performed between the distance of the intersection of the long axis of the first premolar to the hard palate floor and nasal floor, which corresponded to the relevant dimension of available bone for insertion of mini-implants. To evaluate the thickness in median and paramedian regions on CT slice in the region of first premolar, measurements were made between the cortical layer of the nasal floor and hard palate, on central site and paramedian sites 3 mm and 6 mm bilaterally. The measurements were performed by three evaluators. The values found on TNL were not statistically different (p> 0.05) of CBCT (gold standard).The values of the virtual radiography were statistically different (p <0.05) from CBCT and TNL, being underestimated when compared to the gold standard and the radiographic technique. When comparing the measurements of the sites studied, there was no statistical difference (p> 0.05) between the thicknesses of the central site and paramedian sites. It was concluded that the measurements made for planning palatal mini-implants, at the level of the first premolars, is comparable on TNL and multiplanar reconstructions of CBCT, while underestimated in virtual radiography examinations. It is also concluded that the bilateral paramedian regions at 3mm and 6mm from the palatal suture, in the region evaluated, have bone thickness comparable to the median region of the palate / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
54

Estudo dos estagios de desenvolvimento do primeiro molar permanente inferior e sua relação com a idade cronologica em crianças da região de Piracicaba

Gonçalves, Andrea 04 November 1993 (has links)
Orientador: Frab Norberto Boscolo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-18T20:10:28Z (GMT). No. of bitstreams: 1 Goncalves_Andrea_M.pdf: 2111686 bytes, checksum: c5f71040623280010bc80db4170b90d8 (MD5) Previous issue date: 1993 / Resumo: o presente trabalho teve a finalidade de estudar os estágios de desenvolvimento do primeiro molar permanente inferior e sua relação com a idade cronológica em crianças leucodermas da região de Piracicaba. O estudo contou com um total de 102 meninos e 104 meninas com idades entre 24 e 119 meses (2 anos e 9 anos 11 meses), que foram submetidos a uma tomada radiográfica obliqua em norma lateral. As radiografias foram utilizadas para detectar a faixa etária em que o primeiro molar permanente inferior apresentava a coroa totalmente formada, a raiz com 2/3 formados e, finalmente, o ápice radicular formado. Sobre esses achados radiográficos foram organizadas tabelas. Elas mostraram que o estágio de coroa totalmente formada se estendeu de 36 a 53 meses, para o sexo masculino, e de 30 a 53 meses, para o sexo feminino. O estágio de 2/3 de formação radicular do primeiro molar permanente inferior abrangeu a faixa etária de 54 a 119 meses, para o sexo masculino, e de 60 a 119 meses, para o sexo feminino. Por fim, o estágio de ápice radicular formado para ambos os sexos, compreendeu a faixa etária a partir de 102 a 119 meses. Os resultados permitiram observar que não houve diferença entre os estágios de desenvolvimento dentário quando comparados os sexos para uma determinada faixa etária, ou seja, a velocidade de desenvolvimento do primeiro molar permanente inferior, nos estágios, é a mesma para os dois sexos / Abstract: The present paper has had the purpose of studying the development stages of the right permanent mandibular first molar and its relationship with the cronological age of white children in the region of piracicaba. About 102 boys and 104 girls, between the ages of 24 months and 119 months (2 years and 9 years 11 months) were submited to a radiographic examination, the oblique jaw radiography. These radiographs were used to estimate the ages when the permanent mandibular first molar had the crown completed at alI, 2/3 of root completed and, finally, the apical end of root completed. Tables were made on these radiographic results which showed that the stage of crown completed extended from 36 to 53 months for the males and from 30 to 53 months for the females; the stage of 2/3 of root completed of the right permanent mandibular first molar showed the ages from 54 'to 119 months for the males and 60 to 119 months for the females and, at last, the stage of the apical end of root completed extended from 102 to 119 months for both sex. The results permited to observe that there wasn't any difference between the dental development stages when we compared the sex with a determined age: the rate of mineralization of the right permanent mandibular first molar in the stages was the same for both sex / Mestrado / Radiologia Odontologica / Mestre em Odontologia
55

Estimativa da idade, apos os 15 anos, utilizando-se das medidas da camara pulpar e do canal radicular de dentes humanos, atraves de radiografias padronizadas

Camargo, Jose Roque 19 July 2018 (has links)
Orientador: Eduardo Daruge / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-19T13:37:04Z (GMT). No. of bitstreams: 1 Camargo_JoseRoque_M.pdf: 1112793 bytes, checksum: 40be3d28953488b0f96e9b3d620df922 (MD5) Previous issue date: 1994 / Resumo: O autor realizou um trabalho para estimar a idade dos indivíduos pela análise das medidas das Áreas da Câmara pulpar, Área Externa do dente e % proporcional da Área da Câmara pulpar. Para tanto, o autor utilizou-se de 61 dentes humanos representados pelos incisivos centrais e caninos superiores, dentes estes, de indivíduos de arnbos os sexos, leucodermas, com idades variando entre quinze e sessenta e cinco anos. Os dentes citados, foram radiografados através de uma técnica padronizada. Uma vez obtida as radiografias, estas foram ampliadas em dez vezes com o uso de um projetor valores obtidos através da medida do perímetro da imagem do dente envolvendo coroa e ralz. O mesmo conceito será utilizado para as áreas da câmara pulpar e canal radicular. A partir destes dados, conseguimos obter uma percentagem proporcional entre a Área da Câmara pulpar e canal radicular e a área do dente. O autor concluiu, por meio do estudo da análise de regressão linear da amostra, que a Área da Cãmara pulpar e a % proporcional da Área da Câmara pulpar são os indicadores que apresentam maior segurança na estimativa da idade, após os quinze anos, com uma variação de quatro anos em torno da idade estimada / Abstract: Not informed. / Mestrado / Odontologia Legal e Deontologia / Mestre em Ciências
56

A influ?ncia de implantes dent?rios em imagens de radiografia periapical, panor?mica e tomografia computadorizada de feixe c?nico

Felix, Rafael Perdomo 30 March 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-05-21T20:19:16Z No. of bitstreams: 1 469176 - Texto Completo.pdf: 1075538 bytes, checksum: c372985d28935427b18fce7ee072399d (MD5) / Made available in DSpace on 2015-05-21T20:19:16Z (GMT). No. of bitstreams: 1 469176 - Texto Completo.pdf: 1075538 bytes, checksum: c372985d28935427b18fce7ee072399d (MD5) Previous issue date: 2015-03-30 / Imaging exams performed in areas with the presence of metallic materials such as dental implants can decrease the accuracy of the exams due to metallic artifacts production generated in the peri-implant region. A sample of 21 dental implants placed in 10 patients with Branemark protocol prostheses was evaluated in the periimplant area in image exams of the post-surgery control using periapical radiography (paralleling technique), panoramic radiography and cone-beam computed tomography (CBCT). The radiographic density of different areas bounded near the dental implants were calculated and compared considering their locations and the imaging exams using the software ImageJ. Regarding the different imaging exams, the CBCT showed significant differences between the measured areas (p<0.001), while in periapical (p=0.430) and panoramic (p=0.149) radiographs did not occur significant difference between the gray mean values in these areas. Comparing the areas in the three exams it was observed larger values next to the implants in all exams: CBCT (126.20 and 127.44) panoramic radiography (106.51 and 106.09) and periapical radiography (120.32). The more distant areas and the areas closest to neighboring implants had significant different values in the two reconstructed images of CBCT when compared to the panoramic and periapical radiographs. The interference of dental implants in acquiring radiographic and tomographic exams was confirmed by altered radiographic density mean values in the peri-implant area. Comparing the three exams it was noticed that the CBCT image showed the most significant interference of the dental implants. / Os exames por imagem realizados em ?reas que apresentam materiais met?licos, como implantes dent?rios, podem ter sua qualidade prejudicada devido ? produ??o de artefatos met?licos gerados na regi?o peri-implantar. Uma amostra de 21 implantes dent?rios, em 10 pacientes com pr?teses do tipo protocolo Branemark, foi avaliada com o objetivo de comparar as densidades radiogr?ficas na regi?o periimplantar em exames de imagens de controle p?s-operat?rio com radiografia periapical (t?cnica do paralelismo), radiografia panor?mica e tomografia computadorizada de feixe c?nico. Os valores m?dios de densidade em ?reas delimitadas pr?ximas aos implantes dent?rios foram calculados e comparados, de acordo com suas localiza??es, e entre os exames de imagens utilizando o programa ImageJ. Os exames de Tomografia Computadorizada de Feixe C?nico (TCFC) apresentaram diferen?as significativas entre as ?reas medidas (p<0,001), enquanto que nas radiografias periapical (p=0,430) e panor?mica (p=0,149) n?o houve diferen?a significativa entre os valores m?dios de densidade nas mesmas ?reas. Na compara??o entre as ?reas dos tr?s exames, observou-se valores maiores naquelas pr?ximas aos implantes em todos os exames: TCFC (127,88 e 120,71), panor?mica (106,51 e 106,09) e periapical (120,32). As ?reas mais distantes e pr?ximas aos implantes vizinhos mostraram valores significativamente diferentes nos dois cortes da TCFC quando comparados aos exames periapical e panor?mico. Sendo assim, foi poss?vel confirmar a interfer?ncia dos implantes dent?rios na obten??o dos exames radiogr?ficos e tomogr?ficos, pela altera??o dos valores m?dios de densidade radiogr?fica na regi?o peri-implantar. Na compara??o entre os tr?s exames de imagem investigados, verificou-se que as imagens de TCFC sofreram a maior interfer?ncia dos implantes dent?rios, quando comparadas com as imagens radiogr?ficas.
57

Perda ?ssea marginal em implantes distais em pr?teses fixas implantossuportadas : desenvolvimento metodol?gico para estudo prospectivo radiogr?fico

Camargo, Bernardo Alievi 31 March 2014 (has links)
Made available in DSpace on 2015-04-14T13:30:33Z (GMT). No. of bitstreams: 1 458942.pdf: 1319347 bytes, checksum: 53009a393ff35022421155e36d99405d (MD5) Previous issue date: 2014-03-31 / Previous biomechanical studies show a great stress concentration at the distal region of implants adjacent to the cantilever in fixed implant-supported complete dentures (FISCD). Thus, it is necessary to evaluate the marginal bone levels in this region by means of intraoral radiographs. The objectives of this study were: 1) to develop a specific methodological approach for the radiographic evaluation of marginal bone loss (MBL) around the most distal implants adjacent to prosthetic cantilever in FISCD, 2) to investigate possible correlation between MBL, cantilever extension and mesio-distal inclination of the distal implants. Seven patients with 10 FICSD (n=20 implants) were accompanied during one year at the clinics of Faculty of Dentistry of PUCRS. Measurements of the cantilever extension of the metallic infrastructures were carried out during the prosthetic rehabilitation. The mesio-distal inclinations of the implants relative to the occlusal plane were defined through the cone beam computer tomography (CBCT). Intra-oral digital radiographs were obtained by customized positioning devices following delivery of the prostheses (baseline) and one year after the delivery. Cantilever extension, inclination and MBL of the distal implants were analyzed descriptively and inferentially: the correlation between MBL, cantilever extension and inclination of the implants were evaluated by Spearman&#8223;s correlation coefficient with significance level of 5%. The mean values and their variability were; cantilever extension 9,80? 3,69 mm, distal inclination 2,50 (1,00; 10,50) degrees, mesial inclination -3,00(-5,00; -1,00) degrees, mesial MBL -0,08 (-0,28; 0,05) mm and distal MBL -0,04(-0,35; 0,09) mm. No statistical correlation was detected neither between MBL and cantilever extension nor between MBL and inclination of the distal implants. The proposed radiographic and methodological technique used in this study was reliable and reproducible. The findings of MBL after 1 year of follow-up were in accordance with the literature. / Estudos biomec?nicos anteriores mostram que h? uma maior concentra??o de for?as na regi?o distal dos implantes adjacentes ao cantilever prot?tico em Pr?teses Totais Fixas Implantossuportadas (PTFIs), o que leva ? necessidade de avalia??o ?ssea periimplantar nessa regi?o com radiografias intra-orais. Os objetivos deste trabalho foram o desenvolvimento de uma metodologia espec?fica para avaliar radiograficamente a perda ?ssea linear em implantes mais distais, adjacentes ao cantilever prot?tico em PTFIs e investigar sua poss?vel correla??o com extens?o de cantilever e inclina??o m?sio-distal do implante. Foram acompanhados sete pacientes com 10 PTFIs (N=20 implantes) durante um ano, nas cl?nicas da Faculdade de Odontologia da PUCRS. A medi??o da extens?o de cantilever prot?tico na infraestrutura met?lica foi realizada durante o tratamento. A inclina??o m?sio-distal dos implantes foi adquirida atrav?s de Tomografia computadorizada Cone Beam (CBCT) considerando o plano oclusal como refer?ncia. Foram realizadas radiografias intra-orais digitais, utilizando posicionadores customizados, ap?s a entrega da pr?tese (baseline) e no acompanhamento de um ano. Extens?o de cantilever, inclina??o dos implantes e perda ?ssea foram analisados de forma descritiva e inferencial; a correla??o entre perda ?ssea, extens?o de cantilever e inclina??o do implante foi efetuada com coeficiente de correla??o de Spearman ao n?vel de signific?ncia de 5%. Os valores m?dios e sua variabilidade foram: extens?o de cantilever 9,80? 3,69 mm, Inclina??o Distal 2,50 (1,00; 10,50) graus, Inclina??o Mesial -3,00 (-5,00; -1,00) graus e perda ?ssea M -0,08 (-0,28; 0,05) mm e perda ?ssea D -0,04 (-0,35; 0,09) mm. N?o houve correla??o estat?stica nem entre perda ?ssea marginal e extens?o de cantilever prot?tico nem entre perda ?ssea marginal inclina??o dos implantes mais distais. Este trabalho demonstrou que a t?cnica de obten??o e an?lise das imagens radiogr?ficas ? confi?vel e reprodut?vel. Os achados de perda ?ssea em um ano est?o de acordo com a literatura.
58

Rela??o da velocidade de crescimento mandibular com est?gios de ossifica??o das v?rtebras cervicais

Chevarria, Marcos Gonzales 19 January 2007 (has links)
Made available in DSpace on 2015-04-14T13:30:39Z (GMT). No. of bitstreams: 1 389375.pdf: 1505128 bytes, checksum: 29ca32c28db465421da5e36f67d4e748 (MD5) Previous issue date: 2007-01-19 / Este estudo avaliou a velocidade de crescimento da mand?bula considerando a rela??o do crescimento com a matura??o esquel?tica das v?rtebras cervicais, em indiv?duos brasileiros, portadores de maloclus?o de Classe I, II e III esquel?tica, durante o per?odo puberal. Foram analisadas telerradiografias de perfil, obtidas em dois momentos, com intervalo de 6 a 18 meses, de 133 indiv?duos, sendo 54 do g?nero masculino e 79 do feminino, com idades entre 7 e 18 anos de idade. A amostra foi dividida em cinco grupos, de acordo com os est?gios de matura??o das v?rtebras. As telerradiografias de perfil foram tra?adas e os pontos cefalom?tricos digitalizados no Software DentoFacial Planner Plus (DFL Plus, 2.0). O ?ngulo ANB foi determinado para caracteriza??o da amostra. Foram avaliadas as dist?ncias entre Co-Go, Go-Gn e Co-Gn entre as duas cefalometrias, obtendo-se uma taxa de crescimento anual. No tratamento estat?stico utilizou-se an?lise de vari?ncia e teste de Tukey para comparar a velocidade de crescimento mandibular entre os est?gios de matura??o das v?rtebras cervicais e entre as classes, e teste t-student para comparar a velocidade de crescimento entre os g?neros. Os resultados indicaram que a velocidade m?dia de crescimento da mand?bula foi maior no est?gio 2 de matura??o das v?rtebras cervicais. Os indiv?duos do g?nero masculino apresentaram pico de velocidade de crescimento nos est?gios 2 e 3, enquanto nos indiv?duos do g?nero feminino, a velocidade de crescimento da mand?bula foi maior nos est?gios 1, 2 e 3. Embora os indiv?duos com padr?o esquel?tico de Classe III exibissem as maiores dimens?es iniciais da mand?bula, verificou-se similaridade para as velocidades de crescimento da mand?bula entre os portadores de Classes I, II e III
59

Influ?ncia do alargamento apical no reparo das periodontites apicais : estudo em ratos

Jara Pintos, Cynthia Mireya 31 March 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-07-14T16:53:43Z No. of bitstreams: 1 DIS_CYNTHIA_MIREYA_JARA_PINTOS_PARCIAL.pdf: 371392 bytes, checksum: 528398d153921d783f625b2c5138e0ed (MD5) / Made available in DSpace on 2016-07-14T16:53:43Z (GMT). No. of bitstreams: 1 DIS_CYNTHIA_MIREYA_JARA_PINTOS_PARCIAL.pdf: 371392 bytes, checksum: 528398d153921d783f625b2c5138e0ed (MD5) Previous issue date: 2016-03-31 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Introduction: Instrumentation is considered one of the most important steps in endodontic treatment. The literature is controversial with regards to the optimal apical enlargement, especially as to the repair of periapical lesions, proposing different protocols and instrumentation techniques. This study aimed to evaluate the influence of apical enlargement in the process of apical repair in rats. Methods: 24 Wistar rats were divided into 03 experimental groups. Periapical lesion of the first molars on both sides was induced, leaving the root canals exposed to the oral cavity for three weeks. Group 01 consisted of preparation until a #20 file, Group 02 until #25 and Group 03 until #30 file. One molar has been instrumented, while the opposite side was a negative control for apical repair. Root canals were filled 0.5 mm from the apex, with single cone technique of gutta-percha and sealer. After three weeks, the animals were euthanized. Periapical repair was evaluated by digital radiographs and optical microscopy of histological sections (HE) and the data were analyzed using ANOVA test and Kruskal-Wallis test, aiming to establish whether the progressive increase of apical preparation provides an additional benefit in apical repair. Results: Periapical repair was evaluated using digital radiographs. Radiographic limits of the lesions were marked, finding a significant difference (p ? 0.05) in the repair in favor of all groups compared to their respective controls. These results were supported by histological analysis. There was a trend towards improvement in the periapical healing for the larger apical enlargement (group 3). Conclusion: No significant difference was found between the three experimental groups, but it was possible to appreciate radiographically an improving trend for the group of more instrumentation (third group: #30). / Introdu??o: A instrumenta??o ? considerada uma das etapas mais importantes no tratamento endod?ntico. A literatura ? inconclusiva quanto ao alargamento ideal de prepara??o apical, propondo diferentes protocolos e t?cnicas de instrumenta??o, principalmente no que tange ao seu efeito no reparo de les?es periapicais. Portanto, o objetivo deste estudo foi avaliar a influ?ncia do alargamento apical no reparo dos tecidos periapicais de ratos com periodontite apical induzida. M?todos: Foram utilizados 24 ratos Wistar distribu?dos em 03 grupos experimentais. A primeira fase consistiu na indu??o da forma??o das les?es periapicais nos primeiros molares inferiores de ambos os lados, deixando os canais radiculares expostos ao meio oral por tr?s semanas. A seguir, no Grupo 01 o preparo pela t?cnica seriada foi realizado at? o instrumento #20, no grupo 02 at? #25 e no Grupo 03 at? #30. Os canais foram obturados 0,5 mm aqu?m do forame apical, pela t?cnica do cone ?nico de guta-percha e cimento AH Plus e posteriormente selados com cimento de ion?mero vidro. Ap?s tr?s semanas foi realizada a eutan?sia. O reparo periapical foi avaliado atrav?s de radiografias digitais e analises histol?gica e os dados obtidos foram analisados por meio dos testes de ANOVA e Kruskal-Wallis com o objetivo de determinar se o aumento progressivo da prepara??o apical fornece um benef?cio adicional na repara??o apical. Resultados: Foi observada uma diferen?a significativa (p?0,05) no reparo a favor de todos os grupos experimentais quando comparando aos seus respectivos controles. Estes resultados foram respaldados pela analise histol?gica. Radiograficamente, observou-se leve tend?ncia de melhora na cicatriza??o periapical para o maior alargamento apical (grupo 3). Conclus?o: Nenhuma diferen?a significativa foi encontrada entre os tr?s grupos experimentais, mas foi poss?vel apreciar radiograficamente uma tend?ncia de melhoria no grupo de maior instrumenta??o (grupo 3: # 30).
60

Avaliação de diferentes métodos para sobreposições cefalométricas na maxila e mandíbula em telerradiografias em norma de 45 graus. Estudo com implantes metálicos

Bronzi, Evandro da Silva [UNESP] 29 August 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-08-29Bitstream added on 2014-06-13T20:07:28Z : No. of bitstreams: 1 bronzi_es_dr_arafo.pdf: 1101377 bytes, checksum: 2fd7b6856c709e7fcdae073389cc9ac2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Um estudo cefalométrico longitudinal e retrospectivo foi desenvolvido com o propósito de estudar diferentes métodos de sobreposições cefalométricas para a maxila e mandíbula. O método dos pontos cefalométricos (PC) para sobreposições parciais na maxila (BRONZI, 2002) e os métodos das estruturas anatômicas para sobreposições na maxila e mandíbula (SAKIMA et al., 2004) foram comparados o método dos implantes metálicos (padrão ouro) para verificar sua confiabilidade. Foram selecionadas telerradiografias em norma de 45 graus do lado esquerdo de 19 indivíduos, com faixa etária entre 6,7 anos e 10,2 anos. As radiografias foram tomadas em um mesmo aparelho de raios X, com um intervalo de tempo médio de 1 ano. O principal critério de inclusão era a presença de implantes metálicos em todas as telerradiografias. Análises intra-examinador e inter-examinadores foram realizadas para verificar a confiabilidade de diferentes examinadores nas mensurações realizadas na pesquisa. Foram verificadas as médias das diferenças das mudanças nas posições dentárias (coroa e raiz) da radiografia inicial para a final, em cada tipo de traçado cefalométrico quando comparado aos implantes metálicos nos métodos testados. Após análise estatística de Wilcoxon e verificação das médias e desvio padrão das medidas analisadas, é permitido sugerir sobreposições parciais na maxila em pontos cefalométricos e estruturas anatômicas para telerradiografias em norma de 45 graus. Para as sobreposições cefalométricas em estruturas anatômicas na mandíbula, poderiam ser sugeridas apenas no sentido horizontal, provavelmente pela dificuldade de marcação das estruturas anatômicas em algumas radiografias, principalmente o canal mandibular. As análises intra-examinador e inter-examinadores demonstraram uma boa confiabilidade dos métodos de sobreposições... / A study longitudinal and retrospective cephalometric was developed with the purpose of studying different methods of maxillary and mandibular cephalometrics superimposition. The method of the cephalometric points (PC) for partial maxillary superimposition (BRONZI, 2002) and the methods of the anatomical structures for maxillary and mandibular cephalometrics superimposition (SAKIMA et al., 2004) they were compared the method of the metallic implants (golden standard) to verify his reliability. Forty-five degrees cephalometric radiographs of 19 persons, left side, aged between 6,7 years and 10,2 years were selected. The x-rays were taken in a same X ray device, with an interval of medium time 1 years old. The main inclusion criterion was the presence of metallic implants in all radiographs. Analyses intra-examiner and inter-examiners were accomplished to verify the different examiners' reliability in the mensurements accomplished in the research. The averages of the differences of the changes in the dental positions (it crowns and root) were verified of the initial x-ray for to final, in each type of cephalometric tracing when compared to the metallic implants in the tested methods. After statistical analysis of Wilcoxon and verification of the averages and standard deviation of the analyzed measures, it is allowed to suggest partial superimposition maxillary in the points cephalometrics and anatomical structures for 45º cephalometric radiography. For the mandibular superimposition in anatomical structures, they could just be suggested in the horizontal reference, probably for the difficulty of demarcation of the anatomical structures in some x-rays, mainly the mandibular canal. The analyses intra-examiner and inter-examiners demonstrated a good reliability for the methods of cephalometric superimposition, with results inferior for the method of mandibular cephalometric superimposition in anatomical structures.

Page generated in 0.4721 seconds