Spelling suggestions: "subject:"ententes - radiografia"" "subject:"ententes - hadiografia""
41 |
Influencia dos tecidos moles em imagens radiograficas de lesões osseas periapicais produzidas artificialmente em mandibulas de suinosAquilino, Raphael Navarro 23 April 2003 (has links)
Orientador: Agenor Montebello Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T00:59:33Z (GMT). No. of bitstreams: 1
Aquilino_RaphaelNavarro_M.pdf: 4648047 bytes, checksum: ea26eaf85aea77fdfbbb6e09482be832 (MD5)
Previous issue date: 2004 / Resumo: Com o objetivo de analisar a influência radiográfica dos tecidos moles, na capacidade de diagnóstico de lesões ósseas periapicais, realizou-se um estudo onde foram utilizados seis segmentos posteriores de mandíbulas de suínos, divididos em três grupos de amostra: 1°-) Grupo Tecidos Moles; 2°-) Grupo Macerado com Simulador de Tecidos Moles; 3°-) Grupo Macerado. Lesões periapicais artificiais de tamanhos diferentes e gradativos foram criadas e radiografias periapicais foram obtidas empregando três método.s de aquisição de imagens, sendo o convencional e os digitais Digora e DenOptix. Três observadores analisaram as imagens e puderam manipular brilho, contraste e zoom quando nos sistemas digitais. Para a avaliação interexaminadores utilizou se o teste de Friedmam e intra-examinadores o teste de Kappa. Os resultados mostraram que não houve diferenças estatisticamente significativas entre métodos de aquisição de imagens e entre os grupos de amostra no diagnóstico de lesões ósseas periapicais em mandíbulas de suínos (p<0.05). O sistema DenOptix e o grupo macerado com simulador de tecidos moles apresentaram maior
concordância no diagnóstico de lesões ósseas periapicais em mandíbulas de suínos com valores de Kappa de 0,3-0,51 entre os métodos de aquisição de imagens e entre os grupos de amostra. Concluiu-se que os tecidos moles não influenciaram no diagnóstico de lesões ósseas periapicais em mandíbulas de suínos e que também a manipulação do brilho, contraste e zoom não influenciaram no diagnóstico destas lesões / Abstract: With the purpose to evaluate the radiographic influence of soft tissues in the diagnosis of periapical bone lesions, was realized a study in six segments of swine mandibles divided in three groups: 1°-) Soft tissues Group; 2°-) Dry with Soft Tissues simulator Group and; 3°-) Dry Group. Artificial bone lesions were created in different sizes and gradatives and periapical radiographs were obtained using three systems of images acquisition , being the conventional and the digitals Digora and DenOptix. Three observers analyzed the images e they could manipulated the brightness, contrast and zoom in the digital systems. To the interexaminers evaluation utilized the Friedman Statistical Test and the intraexaminers the Kappa Statistical Test. The results showed that there was no significant statistical difference between the systems of images acquisition and between the groups in the diagnosis of periapical bone lesions in swine mandibles(P<0.05). The DenOptix System and the Dry with Soft Tissues Simulator showed greater agreement in the diagnosis of periapical bone lesions in swine mandibles with Kappa values of 0.3-0.51 between the systems of images acquisition and between the groups. To conclude, the soft tissues had not influenced in the diagnosis of periapical bone lesions in the swine mandibles on periapical radiographic images and the manipulations of brightness, contrast and zoom of the images had not influenced in the diagnosis of these lesions / Mestrado / Mestre em Radiologia Odontológica
|
42 |
SPIRO - sistema para processamento de imagem radiografica odontologicaLauris, Jose Roberto Pereira 05 December 1997 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-23T05:32:32Z (GMT). No. of bitstreams: 1
Lauris_JoseRobertoPereira_M.pdf: 7351306 bytes, checksum: 0df3aa961dd1747bed67c85c155c97da (MD5)
Previous issue date: 1997 / Resumo: O processamento digital de imagens radiográficas tem tido grande impulso nos últimos 10 anos, graças principalmente ao crescente desenvolvimento tecnológico dos microcomputadores e dos equipamentos de digitalização de imagens, além do desenvolvimento de equipamentos de radiografia digital. Com o objetivo de fornecer aos cirurgiões-dentistas, da área de radiologia, ferramentas de processamento de imagem que funcionem em equipamento de baixo custo, e que sejam de fácil utilização, foi desenvolvido o SPIRO - Sistema para Processamento de Imagem Radiográfica Odontológica. O SPIRO foi desenvolvido para ser executado em ambiente operacional MS Windows e permite o processamento de imagens previamente digitalizadas ou com o auxílio de um scanner fazer a digitalização de radiografias odontológicas para posterior processamento. Os processamentos disponíveis são: ampliação e redução, aumento do contraste e brilho, produção de imagem negativa, pseudo-colorização e equalização de histograma. O programa foi testado por 14 cirurgiões-dentistas da área de radiologia e mostrou ter atingido seus objetivos por ser um sistema útil para auxílio ao diagnóstico, de fácil utilização e que pode ser executado em equipamentos de baixo custo / Abstract: The radiological digital image processing has been growing during the last 10 years due to the increasing technological development of microcomputers, to the image digitizing equipment and to the new digital radiographic equipments. In order to help the dentists, especialized on radiology, in improving their diagnosys, we have developed SPIRO (System for the Processing of Odontological Radiographic Images), a digital image processing software tool to run on low cost equipment that is very ease to be used. The software was developed to run under MS Windows and allows the processing of previously digitized images or activates a scanner to do the radiograph digitization for later processing. The processing tools available are: magnification and reduction, contrast and brightness, negative image, pseudo colorization and histogram equalization. The system was tested by fourteen dentists, from the radiologic area, that answered a questionary. The results have shown its usefulness in helping the diagnosys, also that it is user friendly and can run on very low cost equipment / Mestrado / Mestre em Engenharia Elétrica
|
43 |
Estudo comparativo entre as idades cronológica, óssea e dentária em pacientes portadores de anemia de Fanconi / Ana Claudia Galvão de Aguiar Koubik ; orientadora, Beatriz Helena Sotille FrançaKoubik, Ana Claudia Galvão de Aguiar January 2004 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2004 / Inclui bibliografia / A Anemia de Fanconi (AF) é uma doença genética autossômica recessiva, caracterizada clinicamente pela falência progressiva da medula óssea, malformações congênitas, atraso do crescimento e predisposição à leucemia e tumores sólidos. Existem onze subtipos / Fanconi´s anemia (FA) is a genetic autossomal recessive disorder. It is clinically characterized by progressive bone marrow failure, congenital abnormalities, growth retardation and predisposition to leukemia and solid tumors. There are eleven genetic sub
|
44 |
Análise da influência de diferentes resoluções e modos de visualização na obtenção de medidas lineares em radiografias panorâmicas digitalizadas / Larissa Lorena Gallassini ; orientador, Fernando Henrique WestphalenGallassini, Larissa Lorena January 2005 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2005 / Inclui bibliografia / Os objetivos do presente estudo foram avaliar, pelas mensurações lineares do forame mentual e do seio maxilar, a melhor resolução de escaneamento dentre as cinco resoluções utilizadas: 100, 150, 200, 300 e 400 dpi e, também, avaliar a apresentação das ima
|
45 |
Estudo das manifestações clínicas, estomatológicas e radiográficas em pacientes portadores de anemia de Fanconi / Melissa Rodrigues de Araujo ; orientadora, Marina de Oliveira RibasAraujo, Melissa Rodrigues de January 2004 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, 2004 / Inclui bibliografia / A Anemia de Fanconi e uma desordem genetica de heranca autossomica recessiva, com manifestacao clinica heterogenea, caracterizada por uma falencia medular progressiva, malformacoes congenitas e predisposicao ao desenvolvimento de neoplasias, sobretudo leu / Fanconi¡äs anemia is a rare autossomal recessive disorder with heterogeneous clinics, characterized by progressive bone marrow failure, congenital abnormalities and predisposition to malignancies, especially leukemia and solid tumors. There are eleven gen
|
46 |
Influência do estado diabético na doença periodontal induzida em ratos. Análise bioquímica, microscópica, radiográfica e dos níveis de mieloperoxidadeGomes, Débora Aline Silva [UNESP] 17 February 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0
Previous issue date: 2006-02-17Bitstream added on 2014-06-13T19:47:54Z : No. of bitstreams: 1
gomes_das_me_arafo.pdf: 2513950 bytes, checksum: 8cd7796b57e48e98aeb2eb5aa9a87b0d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / Evidências sugerem existir correlação positiva entre diabetes mellitus e destruição periodontal. Com intuito de estudar a influência do Diabetes Mellitus sobre a evolução da doença periodontal induzida, o presente estudo apresenta como objetivos, avaliar o peso corporal, os níveis séricos de cálcio, fósforo e fosfatase alcalina, os níveis teciduais de mieloperoxidase, além de, análise macroscópica e radiográfica dos espécimes de cada animal. Foram utilizados 128 ratos machos Wistar divididos em 4 grupos de 32 ratos, sendo: Grupo I controle; Grupo II diabético; Grupo III controle com doença periodontal induzida e Grupo IV diabético com doença periodontal induzida. Após dois dias da confirmação do estado diabético induzido por estreptozotocina, foi realizada a colocação da ligadura. Oito animais de cada grupo foram sacrificados nos períodos experimentais de 3, 7, 15 e 30 dias após colocação da ligadura. Os resultados demonstraram que o estado diabético perdurou até o final do experimento nos grupos II e IV. Dentre os marcadores bioquímicos, somente a ALP apresentou-se estatisticamente maior nos grupos diabéticos (II e IV). Macroscopicamente, houve diferença somente entre os grupos com e sem doença periodontal, independente da presença do diabetes, com maior alteração tecidual nos períodos tardios de periodontite (30 dias). Os níveis gengivais de MPO foram estatisticamente maiores (p<0.05) nos grupos com doença periodontal induzida (III e IV). Radiograficamente, o grupo IV apresentou maior perda óssea estatisticamente significante quando comparada aos demais grupos (p<0,05). Nos limites deste estudo, pode-se concluir que a doença periodontal induzida não alterou o estado hiperglicêmico, no entanto, sugere-se que o diabetes acentue... / Evidences suggest the existence of a positive correlation between diabetes mellitus and periodontal collapse. In order to evaluate the influence of Diabetes Mellitus on the progression of periodontal disease induced in rats, the objective of the present study was to verify glycemic, calcium, phosphorus and alkaline phosphatase serum levels, to evaluate myeloperoxidase (MPO) gingival levels, as well as to carry out macroscopic and radiographic assessment of the animals' hemimandíbulas of experimental periodontitis. A hundred twenty-eight Wistar male rats were used in this study. They were divided into 4 groups of 32 rats each, as follows: Group I - control; Group II - diabetic; Group III - control with periodontal disease induced; and Group IV - diabetic with periodontal disease induced. After streptozotocin diabetic state was confirmed, a ligature was placed on the mandibular first molar teeth of Groups III and IV rats. Eight animals of each group were killed at the experimental periods of 3, 7, 15 and 30 days after the ligature placement. Results demonstrated that the diabetic state lasted up to the end of the experiment at groups II and IV. Significant increases in serum alkaline phosphatase were observed at diabetic groups (II and IV). Macroscopically, in the groups where periodontal disease was induced, it was possible to observe more tissue alterations and it was higher in the 30-day experimental period. The MPO levels were significantly higher in induced periodontitis groups (III and IV) (p<0.05). Radiographically, diabetic with experimental periodontitis group (IV) showed statistically higher bone loss in all the experimental periods (p<0.05). It is possible to conclude that induced periodontal disease did not change the diabetic state... (Complete abstract, click electronic address below)
|
47 |
A influência de implantes dentários em imagens de radiografia periapical, panorâmica e tomografia computadorizada de feixe cônicoFelix, Rafael Perdomo January 2015 (has links)
Made available in DSpace on 2015-05-22T12:38:47Z (GMT). No. of bitstreams: 1
000469176-Texto+Completo-0.pdf: 1075538 bytes, checksum: c372985d28935427b18fce7ee072399d (MD5)
Previous issue date: 2015 / Imaging exams performed in areas with the presence of metallic materials such as dental implants can decrease the accuracy of the exams due to metallic artifacts production generated in the peri-implant region. A sample of 21 dental implants placed in 10 patients with Branemark protocol prostheses was evaluated in the periimplant area in image exams of the post-surgery control using periapical radiography (paralleling technique), panoramic radiography and cone-beam computed tomography (CBCT). The radiographic density of different areas bounded near the dental implants were calculated and compared considering their locations and the imaging exams using the software ImageJ. Regarding the different imaging exams, the CBCT showed significant differences between the measured areas (p<0. 001), while in periapical (p=0. 430) and panoramic (p=0. 149) radiographs did not occur significant difference between the gray mean values in these areas. Comparing the areas in the three exams it was observed larger values next to the implants in all exams: CBCT (126. 20 and 127. 44) panoramic radiography (106. 51 and 106. 09) and periapical radiography (120. 32). The more distant areas and the areas closest to neighboring implants had significant different values in the two reconstructed images of CBCT when compared to the panoramic and periapical radiographs. The interference of dental implants in acquiring radiographic and tomographic exams was confirmed by altered radiographic density mean values in the peri-implant area. Comparing the three exams it was noticed that the CBCT image showed the most significant interference of the dental implants. / Os exames por imagem realizados em áreas que apresentam materiais metálicos, como implantes dentários, podem ter sua qualidade prejudicada devido à produção de artefatos metálicos gerados na região peri-implantar. Uma amostra de 21 implantes dentários, em 10 pacientes com próteses do tipo protocolo Branemark, foi avaliada com o objetivo de comparar as densidades radiográficas na região periimplantar em exames de imagens de controle pós-operatório com radiografia periapical (técnica do paralelismo), radiografia panorâmica e tomografia computadorizada de feixe cônico. Os valores médios de densidade em áreas delimitadas próximas aos implantes dentários foram calculados e comparados, de acordo com suas localizações, e entre os exames de imagens utilizando o programa ImageJ. Os exames de Tomografia Computadorizada de Feixe Cônico (TCFC) apresentaram diferenças significativas entre as áreas medidas (p<0,001), enquanto que nas radiografias periapical (p=0,430) e panorâmica (p=0,149) não houve diferença significativa entre os valores médios de densidade nas mesmas áreas. Na comparação entre as áreas dos três exames, observou-se valores maiores naquelas próximas aos implantes em todos os exames: TCFC (127,88 e 120,71), panorâmica (106,51 e 106,09) e periapical (120,32). As áreas mais distantes e próximas aos implantes vizinhos mostraram valores significativamente diferentes nos dois cortes da TCFC quando comparados aos exames periapical e panorâmico. Sendo assim, foi possível confirmar a interferência dos implantes dentários na obtenção dos exames radiográficos e tomográficos, pela alteração dos valores médios de densidade radiográfica na região peri-implantar. Na comparação entre os três exames de imagem investigados, verificou-se que as imagens de TCFC sofreram a maior interferência dos implantes dentários, quando comparadas com as imagens radiográficas.
|
48 |
Relação da velocidade de crescimento mandibular com estágios de ossificação das vértebras cervicaisChevarria, Marcos Gonzales January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:41Z (GMT). No. of bitstreams: 2
000389375-0.pdf: 1505128 bytes, checksum: 29ca32c28db465421da5e36f67d4e748 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This research evaluated the relationship of the mandibular growth velocity to the cervical vertebrae skeletal maturation, in Brazilian Class I, II e III individuals, during puberal period. The lateral cephalometric radiographs of 133 individuals, among 7 and 18 years of age, beeing 54 males and 79 females, obtained in two distinct moments in a 6 to 18 month interval, were evaluated. The sample were divided into five groups according to their cervical vertebrae skeletal maturation. The lateral head films were traced and digitalized on the Dentofacial Planner Plus Software (DFP Plus, 2. 0). The distances between Co-Go, Go-Gn and Co-Gn were analized and an anual growth rate was determined. Analisys of variance, Tukey test and t-student test was aplied. The results showed that the mandibular growth velocity was greater in the maturational stage 2. For the male gender, the peak of growth velocity occurs in stages 2 and 3, while the female gender showed higher values in stages 1, 2 and 3. The male gender showed grater growth velocity compared with the females gender. The skeletal Class III individuals presented higher mandibular dimensions, but there were no difference between the annuals growth rates in the Class I, II and III individuals. / Este estudo avaliou a velocidade de crescimento da mandíbula considerando a relação do crescimento com a maturação esquelética das vértebras cervicais, em indivíduos brasileiros, portadores de maloclusão de Classe I, II e III esquelética, durante o período puberal. Foram analisadas telerradiografias de perfil, obtidas em dois momentos, com intervalo de 6 a 18 meses, de 133 indivíduos, sendo 54 do gênero masculino e 79 do feminino, com idades entre 7 e 18 anos de idade. A amostra foi dividida em cinco grupos, de acordo com os estágios de maturação das vértebras. As telerradiografias de perfil foram traçadas e os pontos cefalométricos digitalizados no Software DentoFacial Planner Plus (DFL Plus, 2. 0). O ângulo ANB foi determinado para caracterização da amostra. Foram avaliadas as distâncias entre Co-Go, Go-Gn e Co-Gn entre as duas cefalometrias, obtendo-se uma taxa de crescimento anual.No tratamento estatístico utilizou-se análise de variância e teste de Tukey para comparar a velocidade de crescimento mandibular entre os estágios de maturação das vértebras cervicais e entre as classes, e teste t-student para comparar a velocidade de crescimento entre os gêneros. Os resultados indicaram que a velocidade média de crescimento da mandíbula foi maior no estágio 2 de maturação das vértebras cervicais. Os indivíduos do gênero masculino apresentaram pico de velocidade de crescimento nos estágios 2 e 3, enquanto nos indivíduos do gênero feminino, a velocidade de crescimento da mandíbula foi maior nos estágios 1, 2 e 3. Embora os indivíduos com padrão esquelético de Classe III exibissem as maiores dimensões iniciais da mandíbula, verificou-se similaridade para as velocidades de crescimento da mandíbula entre os portadores de Classes I, II e III.
|
49 |
Comparação entre radiografia interproximal convencional, digital e tomografia computadorizada de feixe cônico na detecção de lesões oclusais de cárie – estudo in vitro / Comparison of interproximal convencional and digital radiography and cone beam computed tomography in the assessment of occlusal caries – in vitro studyPimentel, Paulo Alvino Galvão 18 October 2013 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2013. / Submitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2014-04-11T10:39:55Z
No. of bitstreams: 1
2013_PauloAlvinoGalvaoPimentel.pdf: 200551 bytes, checksum: 7de6dff203bfc61773c0572e2c310ceb (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-04-11T13:06:51Z (GMT) No. of bitstreams: 1
2013_PauloAlvinoGalvaoPimentel.pdf: 200551 bytes, checksum: 7de6dff203bfc61773c0572e2c310ceb (MD5) / Made available in DSpace on 2014-04-11T13:06:51Z (GMT). No. of bitstreams: 1
2013_PauloAlvinoGalvaoPimentel.pdf: 200551 bytes, checksum: 7de6dff203bfc61773c0572e2c310ceb (MD5) / Objetivo: Comparar a radiografia interproximal (convencional e digital) e a tomografia computadorizada de feixe cônico quanto à detecção de lesões oclusais de cárie. Métodos: Os exames de imagem foram realizados em 145 terceiros molares e avaliados por dois especialistas em radiologia que classificaram as imagens quanto à presença de lesões de cárie oclusais. Foram aplicados os testes de Kappa, de McNemar e análise ROC associada aos testes de Mann-Whitney e Qui-quadrado. Resultados: Com o teste Kappa evidenciaram-se graus excelente e moderado de concordância para as avaliações intra e interexaminadores, respectivamente. A partir da aplicação do teste de McNemar, identificou-se diferença estatisticamente significativa (p=0.0026) entre a proporção de dentes diagnosticados com lesão de cárie na radiografia convencional e na tomografia. Para a radiografia digital, a diferença encontrada não foi significativa (p=0.2858). Todos os exames mostraram sensibilidade menor que a especificidade e, utilizando como parâmetro a tomografia, a radiografia digital apresentou resultados discretamente superiores para avaliação das lesões oclusais. Conclusão: As três modalidades diagnósticas estudadas são válidas para abordagem de lesões oclusais de cárie. A radiografia digital e a tomografia computadorizada de feixe cônico mostraram-se discretamente superiores para a identificação dessa patologia. _______________________________________________________________________________________ ABSTRACT / Objective: Compare interproximal radiography (conventional and digital) and cone beam computed tomography in the assessment of occlusal caries. Methods: The imaging studies were performed in 145 third molars and evaluated by two radiologists who rated the images for the presence of occlusal caries. Kappa, McNemar and ROC analysis associated with Mann-Whitney and Chi-square were the statistical tests applied. Results: Kappa test revealed excellent and moderate degree of agreement for intra and inter-evaluations, respectively. From the application of the McNemar test a statistically significant difference (p= 0.0026) between the proportion of teeth diagnosed with caries in conventional radiography and tomography was identified. For digital radiography the difference found was not significant (p= 0.2858). All examinations showed lower sensitivity than specificity. Selecting as parameter the tomographic image, digital radiography showed slightly higher results for the assessment of occlusal lesions. Conclusion: All the diagnostic modalities studied approach is valid for occlusal caries. Digital radiography and cone beam computed tomography proved to be slightly higher to the recognition of this pathology.
|
50 |
Influencia do tempo de espera, de exposição e condições de luz em imagens obtidas por placas de armazenamento de fosforo / Influence of the time and storage conditions on images acquired using phosphor storage platesMartins, Mauro Guilherme de Barros Quirino 12 February 2005 (has links)
Orientador: Francisco Haiter Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-10T08:35:13Z (GMT). No. of bitstreams: 1
Martins_MauroGuilhermedeBarrosQuirino_D.pdf: 459015 bytes, checksum: ab47f5efdd8be44f60da615d4f531069 (MD5)
Previous issue date: 2005 / Resumo: O objetivo deste estudo foi verificar a influência do tempo de espera, tempo de exposição e condição de luz na qualidade final de imagens obtidas por placas de fósforo dos sistemas digitais DenOptix®, Digora® e Vistascan®. As placas foram sensibilizadas com uma escala de densidade, com a finalidade de realizar as análises objetivas, com um ¿phantom¿, constituído a partir de uma mandíbula macerada, para análise subjetiva e com dentes pré-molares, para o diagnóstico de cáries. As análises objetivas foram realizadas pelo valor do pixel dos softwares correspondentes aos sistemas digitais e estes dados, analisados estatisticamente pelos testes de Tukey e Dunnet. A análise subjetiva foi realizada por 3 radiologistas e os dados submetidos ao teste de Mann Whitney. Para o diagnóstico de cáries, foram utilizados oito avaliadores e os dados submetidos aos testes de Wilcoxom e Friedman. Como conclusões: 1. As imagens obtidas pelo sistema Digora® sofreram perda de qualidade de imagem a partir de 4 horas, após a exposição aos raios X; 2. O sistema DenOptix® apresentou-se estável quando submetido a diferentes tempos de exposição adequados e tempos de espera; 3. A qualidade da imagem das placas de armazenamento de fósforo é afetada pela qualidade dos invólucros plásticos disponíveis em cada sistema. Os invólucros do sistema Vistascan® foram capazes de proteger entrada de luz nas condições utilizadas por este estudo / Abstract: The aim of this study was to verify the influence of the delay in scanning, exposure time and light condition in the final quality of images obtained using phosphor storage plates of DenOptix®, Digora® and Vistascan® digital systems. The plates were radiographed with an aluminium step wedge for the objective analysis, with a dry mandible for the subjective analysis and with premolars teeth for caries diagnosis. The objective analysis were carried through by the pixel value obtained from the corresponding softwares of each digital systems and these data analyzed statistically by Tukey and Dunnet tests. The subjective analysis were carried through by 3 radiologists and the data submitted to Mann Whitney U test. For caries diagnosis, eight observers were used and the data submitted to Wilcoxom and Friedman tests. As conclusions: 1. The images obtained using the Digora® system showed loss of quality of image at 4 hours after exposure; 2. The DenOptix® system presented a certain stability when subjected to different delays in scanning and exposure times; 3. The quality of the image of the phosphor storage plates is affected by the quality of the available plastic hygienic bags of each system. The bags of the Vistascan® system were able to protect under all the conditions used in this study / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
|
Page generated in 0.1234 seconds