• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 92
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • Tagged with
  • 92
  • 92
  • 25
  • 25
  • 17
  • 17
  • 14
  • 11
  • 11
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Estudo da qualidade da fundição do titanio comercialmente puro e da união soldada a laser em estruturas de Ti cp e em liga de Ti-6AI-4V / Analysis of titanium casting's situation and of laser-weld joint's quality made in Ti cp and Ti-6AI-4V structures

Nuñez-Pantoja, Juliana Maria Costa 13 August 2018 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T01:45:19Z (GMT). No. of bitstreams: 1 Nunez-Pantoja_JulianaMariaCosta_M.pdf: 1598691 bytes, checksum: 51e66dbbaa613ed9f590b34957e5cd17 (MD5) Previous issue date: 2009 / Resumo: O objetivo desse estudo foi: 1) Examinar por meio de radiografias, a incidência de porosidade interna em estruturas fundidas em titânio comercialmente puro, com diferentes diâmetros de secção transversal; 2) Analisar essa incidência em uniões soldadas a laser, com diferentes distâncias de soldagens, em espécimes de Ti cp e Ti-6Al-4V, variando o diâmetro da secção transversal; 3) Avaliar a resistência à fadiga dessas uniões e correlacionar esses achados com os resultados das analises radiográficas das uniões. Para a primeira análise, 60 halteres (n=20) com diâmetro de 1,5; 2,0 e 3,5 mm de secção transversal foram fundidos em Ti cp, por meio da técnica da cera perdida utilizando-se o sistema Rematitan. Os halteres receberam acabamento e polimento e foram submetidos à análise radiográfica (90 KV, 15 mA, 0,6 segundos e 10 a 13 mm de distância) com filme periapical. As radiografias foram analisadas visualmente quanto à presença de porosidade interna em toda a extensão dos halteres, e apenas na porção do diâmetro central. Os resultados foram submetidos ao teste Qui-quadrado (5%). Foi possível visualizar essas porosidades na maioria (91,7%) dos espécimes fundidos, especialmente nos de diâmetros mais delgados. Para a análise radiográfica das uniões soldadas a laser em espécimes de Ti-6Al-4V, 60 halteres com as mesmas dimensões foram usinados em liga de Ti-6Al-4V. Os halteres foram seccionados e soldados utilizando duas distâncias de soldagem (0,0 e 0,6 mm). O cruzamento das variáveis (distância e diâmetro) gerou seis grupos (n=10). A soldagem a laser foi realizada utilizando-se 360V/8ms (1,5 e 2,0 mm) e 380V/9ms (3,5 mm), com foco e freqüência regulados em zero. As uniões receberam acabamento e polimento e foram submetidas à idêntica análise radiográfica, verificando-se a presença de porosidades internas nas uniões. Os resultados, analisados pelo teste Qui-quadrado (5%), permitiram afirmar que é possível visualizar porosidade nas uniões analisadas. Para halteres de 1,5 mm, a incidência foi maior quando a distância entre as partes soldadas era 0,6 mm; ao contrário, para espécimes de 3,5 mm, essa incidência nessa distância foi menor. Para as análises radiográficas das uniões no Ti cp, 60 halteres fundidos e isentos de porosidade interna na região do diâmetro central, com as mesmas dimensões, foram seccionados, soldados e analisados da mesma maneira que para os espécimes de Ti-6Al-4V, sendo possível visualizar poros nas uniões. Em espécimes delgados (1,5 e 2,0 mm), a incidência de porosidade é maior quando a abertura da junta é maior. Entretanto, para espécimes de 3,5 mm a incidência é alta para ambas as distâncias de soldagem, sem diferença estatística. Para o estudo de resistência à fadiga das uniões em Ti-6Al-4V, os mesmos espécimes soldados que foram utilizados no segundo estudo, associados a espécimes intactos formaram 9 grupos (n=10). Esses espécimes foram submetidos a ensaios de ciclagem mecânica e o número de ciclos resistidos até a fratura foi registrado. A superfície de fratura foi examinada por meio de microscópio eletrônico de varredura (MEV). Os testes de Kruskal-Wallis e Dunn (5%) indicaram que o número de ciclos necessários para a fratura foi menor para todos os espécimes com distância de 0,6 mm, e para os espécimes de 3,5 mm distância 0,0 mm. O coeficiente de Spearman (5%) indicou correlação negativa entre número de ciclos e presença de porosidade nas radiografias. Finalmente, para a análise de resistência à fadiga das uniões no Ti cp, os mesmos halteres soldados do terceiro estudo associados a halteres intactos foram submetidos a similares ensaios mecânicos que os realizados no quarto estudo. Os números de ciclos necessários para a fratura foram registrados e a superfície fraturada, examinada igualmente, podendo-se tecer conclusões similares. Assim, concluiu-se que a qualidade das uniões é melhor quando espécimes mais delgados são soldados com justaposição das partes; e que a análise radiográfica é eficiente para se checar a presença de porosidades internas em espécimes fundidos e em uniões soldadas a laser. / Abstract: soldados e analisados da mesma maneira que para os espécimes de Ti-6Al-4V, sendo possível visualizar poros nas uniões. Em espécimes delgados (1,5 e 2,0 mm), a incidência de porosidade é maior quando a abertura da junta é maior. Entretanto, para espécimes de 3,5 mm a incidência é alta para ambas as distâncias de soldagem, sem diferença estatística. Para o estudo de resistência à fadiga das uniões em Ti-6Al-4V, os mesmos espécimes soldados que foram utilizados no segundo estudo, associados a espécimes intactos formaram 9 grupos (n=10). Esses espécimes foram submetidos a ensaios de ciclagem mecânica e o número de ciclos resistidos até a fratura foi registrado. A superfície de fratura foi examinada por meio de microscópio eletrônico de varredura (MEV). Os testes de Kruskal-Wallis e Dunn (5%) indicaram que o número de ciclos necessários para a fratura foi menor para todos os espécimes com distância de 0,6 mm, e para os espécimes de 3,5 mm distância 0,0 mm. O coeficiente de Spearman (5%) indicou correlação negativa entre número de ciclos e presença de porosidade nas radiografias. Finalmente, para a análise de resistência à fadiga das uniões no Ti cp, os mesmos halteres soldados do terceiro estudo associados a halteres intactos foram submetidos a similares ensaios mecânicos que os realizados no quarto estudo. Os números de ciclos necessários para a fratura foram registrados e a superfície fraturada, examinada igualmente, podendo-se tecer conclusões similares. Assim, concluiu-se que a qualidade das uniões é melhor quando espécimes mais delgados são soldados com justaposição das partes; e que a análise radiográfica é eficiente para se checar a presença de porosidades internas em espécimes fundidos e em uniões soldadas a laser. specimens (1.5 and 2.0 mm), the porosity incidence is higher when the joint distance is larger. However, in 3.5 mm specimens, the incidence is high for both joint openings, without statistical difference. To Ti-6Al-4V joints fatigue strength study, the same laser-welded specimens analyzed in second study associated with the intact specimens made a total of 9 groups (n=10). These specimens were submitted to mechanical cyclic tests, and the number of cycles until failure was recorded. The fracture surface was examined with a scanning electron microscope (SEM). Kruskal-Wallis and Dunn test (5%) indicated that the number of cycles required for fracture was lower for all the diameters with joint openings of 0.6 mm, and for 3.5 mm diameter for the 0.0 mm joint openings. The Spearman correlation coefficient (5%) indicated a negative correlation between number of cycles and presence of porosity in radiographies. To CP Ti joints fatigue strength test, the last study, the same laser-welded specimens analyzed in third study associated with the intact specimens were submitted to similar mechanical cyclic test than fourth study. The number of cycles until failure was either recorded and the fracture surface was examined the same way. Conclusions can be weaved similar the anterior study. Within the limitations of these studies, it could be concluded that joints quality is better when thin specimens are welded with no distance among welding parts; and that radiography analyzes are efficient to check internal porosity in casted specimens and in laser-welded joints. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
72

Avaliação de tres metodos radiograficos - periapical, panoramico e sistema digital - no diagnostico de lesões apicais produzidas artificialmente

Santos, Julio Cesar Bento dos 06 February 1999 (has links)
Orientador: Solange Maria Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T12:46:37Z (GMT). No. of bitstreams: 1 Santos_JulioCesarBentodos_M.pdf: 7612034 bytes, checksum: 606a68f5cabb358d723b7501b7c58c5b (MD5) Previous issue date: 1999 / Resumo: O presente estudo teve por finalidade avaliar três métodos radiográficos, radiografia periapical, radiografia panorâmica e sistema digital, no diagnóstico de lesões apicais produzidas artificialmente em mandíbulas maceradas. E se o tamanho das lesões interferem no diagnóstico radiográfico. Para tanto, as lesões apicais foram produzidas utilizando-se brocas esféricas com diâmetros diferentes, permitindo assim que o diâmetro das lesões sofresse alteração em tamanho conforme a broca utilizada. Assim, o estudo foi dividido em 04 fases: fase inicial ou 1, caracterizada pela ausência de lesão; fase 2, caracterizada pela lesão produzida com a broca 6 com medida da ponta ativa de 1,8mm; fase 3, caracterizada pela lesão produzida com a broca 8 com medida da ponta ativa de 2,3mm; fase 4, caracterizada pela lesão produzida com a broca 10 com medida da ponta ativa de 2,7mm; e fase cortical ou 5, quando a lesão atingia as corticais ósseas. Todas as fases foram, realizadas em 04 regiões da mandíbula: incisivo, canino, pré-molares e molares. As radiografias foram obtidas após cada fase e, posteriormente, foram analisadas por 04 radiologistas. Houve diferença estatisticamente significante na fase broca 6 (R) nos incisivos a favor do sistema digital. O mesmo ocorreu na fase cortical (LI) na região de pré-molares. Na região dos molares houve uma diferença etatisticamente significante na fase broca 10 (D) para a radiografia panorâmica e na fase cortical esta técnica foi a menos eficaz. Nas demais fases e regiões não houve uma diferença estatisticamente significante / Abstract: The aim of this study was to evaluate three radiographys techniques: periapical radiography, panoramic and digital radiography, about diagnostic accuracy of artificially produced bony lesions in human jaw dry. The periapical diseases were done using burs numbers 6, 8 and 10 thus allowing the lesions diameter to incresing according to burs size. Therefore, the study was dividided in four phases: phase 1 without periapical disease, phase 2 periapical disease made by bur number 6, phase 3 periapical disease made by bur number 8, phase 4 periapical disease made by bur number 10 and phase 5 periapical disease touchs junction area of the cortex. The phases were in four regions in the jaw, anterior, canine, premolar and molar. The radiographies were evaluated by four oral radiologists observers. The results showed that in the anterior region there was a significant statistically difference only at phase 2, that is the lesion was produced with bur 6, the digital radiography was more successfull and it was also observed in the premolar region in the cortical phase. In the molar region there was a false true result during the inicial phase, without lesion. During phase 4 (burn 10 ) and cortical phase there was a statistically significant difference in favor of the panoramic radiography / Mestrado / Radiologia / Mestre em Odontologia
73

Análise comparativa entre o sistema digital Digora e a digitalização da radiografia convencional na avaliação da densidade radiográfica do processo de reparo alveolar

Silva, Jordan Lima da [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T20:21:53Z : No. of bitstreams: 1 silva_jl_dr_araca.pdf: 803850 bytes, checksum: a13420fee8c9eac95ae85dcbb9659489 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A película radiográfica é uma tecnologia que os cirurgiões-dentistas estão mais familiarizados estando confortáveis em termos da técnica e da interpretação. A radiografia digital é um avanço que está sendo adotado lentamente pelo cirugião-dentista, oferecendo algumas vantagens distintas sobre a película. O propósito deste estudo é comparar o sistema radiográfico digital Digora com a digitalização da radiografia convencional, avaliando a densidade radiográfica do processo de reparo alveolar na região de molares inferiores inclusos após exodontia em humanos. Os princípios e técnica para a exodontia foram padronizados assim como para a obtenção das imagens radiográficas. Imagem sugestiva de tecido ósseo mineralizado foi observada nos períodos de 60 e 90 dias, comparando os sistemas digital e convencional digitalizado. A estatística sugere perda nos valores da densidade, nos períodos estudados, para o sistema das radiografias convencionais digitalizadas em relação ao sistema Digora. Os resultados obtidos permitem concluir que a qualidade da imagem convencional digitalizada é menos precisa quando comparada a digital, para o acompanhamento do reparo ósseo pós-operatório. / Conventional radiographic film It is a technology that the surgeon-dentists more are made familiar being comfortable to in terms of the technique and the interpretation. The digital x-ray is an advance that is being adopted slowly for the dentistry. The digital image incorporates computer science in the captation, the exposition, the distinction, and the storage of the direct radiographic images. The digital image offers some distinct advantages on the film, but as all the emergent technology presents new different challenges and so that the users surpass them. The intention of this study was to evaluate through the radiograpic examination for the Digora system the radiographic density of the behavior of the fabric bone during the process of repair in the region of molar enclosed inferiors after exodontia in human beings. Standardized procedures had been used for the surgery of the patients as well as for the attainment of the radiographic images. Bone suggestive fabric image mineralized was observed in the periods of 60 and 90 days comparing the conventional and digital method. The gotten results allow to conclude that the quality of the digital conventional image is lower efficient than the digital one gotten directly for the accompaniment of the postoperative bone repair.
74

Detec??o de c?ries proximais em radiografias convencionais e digitais : estudo in vitro

Rockenbach, Maria Ivete Bolzan 06 October 2006 (has links)
Made available in DSpace on 2015-04-14T13:29:13Z (GMT). No. of bitstreams: 1 384677.pdf: 3951111 bytes, checksum: 684b9b53ca958aa688d3b2186dfb12ca (MD5) Previous issue date: 2006-10-06 / O objetivo do presente estudo foi comparar as imagens digitais com a radiografia convencional no diagn?stico de c?ries proximais. A amostra foi composta por 51 molares e 24 pr?-molares, distribu?dos em grupos de tr?s dentes, montados em blocos de silicone, e radiografados pela t?cnica interproximal, empregando-se o filme InSight (Kodak) e os sistemas digitais Digora? (Soredex), DenOptix (Gendex) e CygnusRay MPS (Progeny). Foram obtidas 25 radiografias em cada m?todo radiogr?fico e analisadas quatro faces proximais em cada radiografia, totalizando 400 faces. As radiografias foram examinadas individualmente, por um observador, em tr?s diferentes momentos para cada m?todo. As les?es de c?rie foram classificadas de acordo com sua profundidade em: (0), ausente; (1), restrita ao esmalte; (2), atingindo a jun??o amelodentin?ria e (3), estendendo-se para a dentina. Para a obten??o do padr?o-ouro, os dentes foram seccionados e desgastados, sendo examinados histologicamente por estereomicroscopia. Para an?lise da concord?ncia intra-observador utilizou-se o teste de Kendall, com o qual constatou-se uma boa concord?ncia (0,831) entre as tr?s avalia??es realizadas. Foram calculados a acur?cia, a sensibilidade, a especificidade, o valor preditivo positivo (VPP), o valor preditivo negativo (VPN) e o ?ndice Kappa, n?o se observando diferen?as estat?sticas significativas entre os valores para os quatro m?todos estudados (ANOVA, p≥0,05). Os m?todos radiogr?ficos tamb?m foram comparados utilizando-se o teste n?o-param?trico de Friedman, complementado pelo seu teste de compara??es m?ltiplas, e igualmente, n?o se observaram diferen?as estat?sticas significativas entre os quatro m?todos. Ainda, para cada m?todo radiogr?fico calculou-se a curva ROC e, na compara??o entre as ?reas sob estas curvas, n?o se verificaram diferen?as estat?sticas ao n?vel de signific?ncia de 5%. Concluiu-se que a acur?cia diagn?stica das imagens digitais na detec??o de c?ries proximais ? similar ?quela das radiografias convencionais.
75

Estudo radiográfico digital e densitométrico em mandíbulas de suínos, submetidas a osteotomia com brocas de alta e baixa rotação, com refrigeração líquida

Monti, Lira Marcela [UNESP] 09 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-09Bitstream added on 2014-06-13T19:52:59Z : No. of bitstreams: 1 monti_lm_me_araca.pdf: 287560 bytes, checksum: 074e03765d9ead5baba4ea3ffcdf36ee (MD5) / Universidade Estadual Paulista (UNESP) / Avaliou-se, por meio de exames radiográficos digitais e densitométricos, a influência do tipo de instrumento rotatório para corte, no processo de reparação óssea após osteotomias em mandíbula de suíno em tempos controlados. Foram utilizados para o estudo oito suínos da raça Large White, com peso corpóreo inicial variando de 25 a 30 Kg. Dois cortes transversais do meio à base de mandíbula direita foram realizados, um por meio de instrumento rotatório de alta rotação e o outro pela ação da baixa rotação, ambos com irrigação líquida. Após períodos pré-estabelecidos (7, 28, 60 e 90 dias) os animais foram sacrificados e suas mandíbulas retiradas para estudos radiográficos digitais diretos e indiretos, pelo sistema DIGORA e ODR e de densitometria óptica por imagens radiográficas pelo sistema CROMOX. Nos períodos iniciais (7 e 28 dias) as densitometrias foram maiores na região das osteotomias realizadas com alta rotação e nos períodos finais (60 e 90 dias) as densitometrias foram maiores nas osteotomias feitas com baixa rotação, indicando uma melhor reparação óssea final quando do uso de baixa rotação. A análise qualitativa do processo de reparação foi feita pelo sistema ODR, que possibilitou a obtenção de imagens digitais tridimensionais e coloridas, permitindo comparação das espessuras ósseas com as de uma cunha de alumínio, evidenciando que aos sessenta dias a reparação óssea estava aparentemente completa. Os histogramas do DIGORA apontaram valores de médias de nível de cinza nas áreas de osteotomia, evidenciando uma maior quantidade de tons de cinza nas osteotomias de alta rotação nos primeiros tempos, e nas osteotomias com baixa-rotação nos tempos finais. / It was evaluated, through digital and densitometric radiographic exams, the influence of the type of rotating instrument for cut, in the process of bony repair after osteotomy in swine jaw in controlled times. They were used for the study eight Large White swines, with initial corporal weight varying from 25 to 30 Kg. Two traverse cuts of the middle to the base of right jaw were accomplished, one through rotating instrument of high rotation and the other for the action of the low rotation, both with liquid irrigation. After established periods (7, 28, 60 and 90 days) the animals were sacrificed and your mandibles retired for direct and indirect digital radiografic studies, for the DIGORA and ODR systems and of optical densitometry for radiographic images for the CROMOX system. In the initial periods (7 and 28 days) the densitometry were larger in osteotomy areas accomplished with high rotation and in the final periods (60 and 90 days) the densitometry were larger in the osteotomy done with low rotation, indicating a better final bony repair when of the use of low rotation. The qualitative analysis of the repair process was made by the ODR system, that made possible obtaining three-dimensional and colored digital images, allowing comparison of the bony thickness with the one of a wedge of aluminum, evidencing that to the sixty days the bony repair was apparently complete. The histograms of DIGORA pointed values of the averages of ash tones in the osteotomy areas, evidencing a larger amount of ash tones in the osteotomy of high rotation in the first times, and in the osteotomy with low-rotation in the final times.
76

Estudo comparativo dos resultados de enxertos de vidro bioativo e osso autógeno, associados ou não ao plasma rico em plaquetas, em seio maxilar de coelho: análise fractal, densitométrica e histomorfométrica

Suedam, Ivy Kiemle Trindade [UNESP] 10 October 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-10-10Bitstream added on 2014-06-13T19:44:16Z : No. of bitstreams: 1 suedam_ikt_dr_arafo.pdf: 2051837 bytes, checksum: 442046f47964d37176f4cdf82ded3bc6 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do presente estudo foi avaliar o efeito da associação de osso autógeno (OA) e de vidro bioativo (VB) ao plasma rico em plaquetas (PRP) como substitutos ósseos no interior de seios maxilares (SM) de coelhos, por meio de análise radiográfica da densidade óssea e da dimensão fractal e análise histomorfométrica. Adicionalmente, pretendeu-se validar os métodos da densidade óssea e dimensão fractal como indicadores da neoformação óssea. Para tanto, 20 coelhos divididos em dois grupos (G1 e G2) foram submetidos à cirurgia de levantamento de SM. No G1, 10 SM esquerdos foram enxertados com OA e 10 SM direitos com VB. No G2, 10 SM esquerdos foram enxertados com uma combinação de OA+PRP e 10 SM direitos com VB+PRP. Após 90 dias, os animais foram sacrificados e radiografias padronizadas dos SMs foram obtidas. Os valores médios (desvio padrão) da densidade óssea, expressa em milímetros equivalentes de alumínio, para os tratamentos OA, VB, OA+PRP e VB+PRP foram, respectivamente, 1,79(0,316), 2,04(0,398), 1,61(0,285) e 1,53(0,309), sendo que diferenças estatisticamente significantes (p<0,05) foram encontradas entre os valores de VB e OA, e, VB+PRP e VB. Na dimensão fractal, os valores encontrados, que podem variar de 1 a 2, foram 1,48(0,040), 1,35(0,084), 1,44(0,043) e 1,44(0,066), respectivamente. Diferenças significantes (p<0,05) foram encontradas entre os valores de VB e OA, e, OA+PRP e VB. Na histometria, expressa em porcentagem de preenchimento ósseo, os valores obtidos foram 63,30l8,609, 52,65(10,415), 55,25(7,018) e 51,07(10,255), respectivamente. Não foram encontradas diferenças estatísticas entre os tratamentos. Não houve correlação estatisticamente significante entre as variáveis densidade óssea, dimensão fractal e porcentagem de osso. Na análise histológica dos SM tratados com OA observou-se tecido ósseo neoformado, ricamente... / The objective of the present study was to evaluate the use of autogenous bone (AB) and bioactive glass (BG) and the association of these materials with platelet-rich plasma (PRP), as bone substitutes in the rabbit maxillary sinus (MS) by means of radiographical bone density and fractal dimension and by histomorphometrical analysis. In addition, the study aimed at validating the two radiographic methods as indicators of bone formation. Twenty rabbits divided into two groups (G1 and G2) were submitted to sinus lift surgery. In G1, 10 left MS were grafted with AB and 10 right MS were grafted with BG. In G2, 10 left MS were grafted with AB+PRP and 10 right MS were grafted with VB+PRP. Ninety days after, the animals were sacrificed and standardized radiographs were taken. Mean values (standard deviation) of bone density, expressed as aluminium equivalent milimeters, in MS grafted with OA, VB, OA+PRP and VB+PRP were 1,79l0,316, 2,04l0,398, 1,61l0,285 and 1,53l0,309, respectively. Statistically significant differences (p <0,05) were observed in bone density between BG and AB, and between BG+PRP and BG. Mean values of fractal dimension, which can vary from 1 to 2, were 1,48l0,040, 1,35l0,084, 1,44l0,043 and 1,44l0,066, respectively. Significant differences were observed between BG and AB and AB+PRP and BG. Mean values of percentage of bone inside MS, assessed by histometrical analysis were, respectively, 63,30l8,609, 52,65l10,415, 55,25l7,018 and 51,07l10,255. Differences were not statistically significant. No correlations were observed among bone density, fractal dimension and percentage of bone. Histological analysis showed that MS treated with AB presented newly formed and mature lamellar bone, with active bone formation presenting several vessels and osteoblasts. The other groups showed minor bone formation, with a diffuse marrow and thin network of newly... (Complete abstract click electronic access below)
77

Ativador elástico aberto de Klammt no tratamento da má oclusão de classe II divisão 1

Gonçalves, Renata de Cassia [UNESP] 02 April 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-04-02Bitstream added on 2014-06-13T20:17:26Z : No. of bitstreams: 1 goncalves_rc_me_arafo.pdf: 2990242 bytes, checksum: 0e2e2de731af94f3037301803b7c253d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo prospectivo foi avaliar cefalometricamente as alterações esqueléticas e dento-alveolares naturais e induzidas pelo uso do Ativador Elástico Aberto de Klammt no tratamento da má oclusão de Classe II divisão 1. A amostra foi constituída por dois grupos pareados segundo gênero e idade: grupo experimental com 17 indivíduos (10 meninas e 7 meninos) que receberam tratamento com o aparelho de Klammt pelo período de 12 meses e grupo controle com 17 indivíduos não tratados (10 meninas e 7 meninos) observados durante um período de tempo similar. A média de idade inicial foi de 8,5 anos para ambos os grupos. Telerradiografias laterais foram obtidas no início e no final dos períodos de tratamento e observação. O grupo controle foi obtido a partir dos arquivos do Departamento de Clínica Infantil - Ortodontia, da Faculdade de Odontologia de Araraquara, Universidade Estadual Paulista - UNESP. As alterações observadas foram comparadas por meio do teste t de Student, a análise de variâncias foi realizada pelo teste de Levene e a relação entre altura do acrílico oclusal e alterações esqueléticas e dento-alveolares foi avaliada pelo coeficiente de correlação de Pearson. Os resultados demonstraram que o aparelho promoveu restrição dento-alveolar da maxila; aumento do comprimento mandibular total, comprimento do corpo mandibular e altura do ramo sem alterar o ângulo goníaco; aumento das alturas faciais anterior e posterior sem alterar o padrão facial de crescimento; melhora na relação maxilo-mandibular; verticalização dos incisivos superiores; manutenção da inclinação dos incisivos inferiores; redução do overjet e overbite; correção da relação molar de Classe II. O grupo controle mostrou aumento do comprimento maxilar; aumento do comprimento mandibular... / The objective of this prospective work was to evaluate cephalometrically the natural skeletal and dento-alveolar changes and those induced by use of the Klammt's Open Elastic Activator for class II division 1 malocclusion treatment. The sample consisted of two groups paired according to gender and age: treated group with 17 individuals (10 females and 7 males) that received treatment with the Klammt's appliance for period of 12 months and control group of 17 untreated subjects (10 females and 7 males) observed during a similar period of time. The initial mean age was 8.5 years old for the both groups. Lateral cephalometric radiographs were obtained at the beginning and end periods of treatment and observation. The control group was obtained from the files of the Department of Children's Clinic - Orthodontics at Araraquara Dental School, University of State of São Paulo - UNESP. The observed changes were compared by the student's t-test, the analysis of variance was carried out by Levene test and the relationship among the oclusal acrylic height and the skeletal and dento-alveolar changes was analyzed by Pearson's correlation coefficient. The results demonstrated that the Klammt's Open Elastic Activator produced dento-alveolar restriction of maxilla; increase in total mandibular length, body mandibular length, ramus height and no change gonial angle; increase in anterior and posterior face height and no change growth facial pattern; improvement in the maxillomandibular relationship; palatal tipping of the upper incisors; maintenance of the tipping of the lower incisors; reduction in the overjet and overbite, and correction of Class II molar relationship. The control group showed increase in maxillary length, increase in total mandibular length, body mandibular length, ramus height and no change... (Complete abstract, click electronic access below)
78

Avaliação das estruturas anatômicas para sobreposição cefalométrica maxilar utilizando telerradiografias em norma de 45 graus

Bronzi, Evandro da Silva [UNESP] 21 January 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-01-21Bitstream added on 2014-06-13T18:32:10Z : No. of bitstreams: 1 bronzi_es_me_arafo.pdf: 640601 bytes, checksum: 0d65746f66a182b139908ba7275d7753 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Um estudo cefalométrico longitudinal e retrospectivo foi desenvolvido com o propósito de estabelecer um cefalograma para a maxila, encontrar pontos cefalométricos estáveis na telerradiografia em norma de 45 graus, e ainda avaliar se as imagens obtidas de um lado da radiografia oblíqua são compatíveis com o outro lado. Foram selecionadas telerradiografias em norma de 45 graus de 25 indivíduos, com faixa etária entre 12 e 17 anos, apresentando maloclusões de Classe I e Classe II de Angle. Todos os indivíduos possuíam radiografias oblíquas iniciais e finais dos lados direito e esquerdo tomadas em um mesmo aparelho de raios X, com um intervalo de 8 a 16 meses. O principal critério de inclusão era a presença de implantes metálicos em todas as telerradiografias , para sobreposições dos traçados cefalométricos. Após estudos em crânio seco e inspeção visual foi sugerido um cefalograma para a maxila constituído das seguintes estruturas anatômicas: contorno da órbita, uma linha da base do crânio, a região do processo zigomático, limites de seio maxilar, a maxila, o processo zigomático da maxila do lado oposto, o osso zigomático do lado oposto e a órbita do lado oposto. Os pontos cefalométricos sugeridos para servir de parâmetro na sobreposição parcial da maxila, em telerradiografias em norma de 45 graus, foram divididos de acordo com o sentido analisado. No sentido vertical os pontos mais estáveis foram: OS, PZI, ENP e PZMO. No sentido horizontal os pontos sugeridos foram: PZP, PZPI, PZI, ENA e A. As alterações anatômicas ocorridas em todos os pontos cefalométricos do lado esquerdo foram iguais as do lado direito, não havendo diferença entre os lados da tomada radiográfica para telerradiografias em norma de 45 graus. / A longitudinal and retrospective cephalometric study was developed in order to establish a maxillary cephalogram, to identify stable cephalometric landmarks on 45° radiographs, as well as to evaluate if the obtained images from one side are compatible with the ones from the other side. Forty-five degrees cephalometric radiographs of 25 persons, aged between 12 and 17 years, presenting Angle malocclusion: Class I and Class II were selected. All the persons had pre and post right and left oblique radiographs obtained from the same X ray device, with an interval of eight to sixteen months. The primary inclusion criterion was the presence of metallic implants in all radiographs, to obtain the cephalometric tracings superimpositions. After studies in dried skulls and visual inspection, a maxillary cephalogram was suggested using the following anatomical structures: the orbital contour, a cranial base line, the zigomatic process area, maxillary sinus boundaries, the maxilla; the maxillary zygomatic process, zigomatic bone and orbit of the counter side. The cephalometric landmarks suggested to work parameter for maxillary superimposition in 45º cephalometric radiographs were separated in accordance with the evaluated plane. It can be suggested the use of OS, PZI, PNS and PZMO on vertical planes and PZP, PZPI, PZI, ANS and A on horizontal plane considered the points more stable and reproducible in the sample. The anatomical changes observed in all the cephalometric points of the left side were equivalent to the ones of the right side, with no differences between the sides on 45º cephalometric radiographs.
79

Avaliação automatica de parametros fisicos de qualidade de imagem em sistemas de radiologia digital odontologica

Albuquerque, Jorge Andre Girão 29 July 2018 (has links)
Orientador : Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-29T02:59:46Z (GMT). No. of bitstreams: 1 Albuquerque_JorgeAndreGirao_M.pdf: 5796408 bytes, checksum: 09bd57e0a31a84f22f0e6c4d5ab05252 (MD5) Previous issue date: 2001 / Mestrado
80

Estudo comparativo de tres sistemas digitais sem cabo no diagnostico de caries proximais / Comparative study of three wireless digital systems for approximal caries diagnosis

Pontual, Andrea dos Anjos 28 February 2007 (has links)
Orientador: Francisco Haiter Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T19:20:36Z (GMT). No. of bitstreams: 1 Pontual_AndreadosAnjos_D.pdf: 4409755 bytes, checksum: 49aa0ed4836e883074310730a70bc34b (MD5) Previous issue date: 2007 / Resumo: O objetivo, nesse trabalho, foi comparar, de forma objetiva e subjetiva, dois sistemas digitais de placa de armazenamento de fósforo (Digora Optime® e DenOptix®), com o sistema CDR Wireless®, utilizando o filme radiográfico como método radiográfico de referência. Para a análise objetiva, foram obtidas imagens radiográficas de uma escala de densidade de Alumínio utilizando os três sistemas digitais. Posteriormente, obtiveram-se os valores do pixel por meio de ferramenta apropriada do software EMAGO®/Advanced. A comparação dos valores médios do pixel dos sistemas digitais foi realizada pelos testes de Kruskal-Wallis e de comparações múltiplas de Dunn (p<0,01). Para a avaliação subjetiva, foram obtidas imagens radiográficas de 20 phantoms constituídos de dentes posteriores, as quais foram avaliadas quanto à presença de cáries por seis radiologistas. Posteriormente, os dentes foram seccionados e analisados microscopicamente para obtenção do padrão ouro. Foram realizados a análise de variância e o teste-t (p<0,05) com o objetivo de verificar a ocorrência de diferença estatisticamente significativa entre os valores de sensibilidade, especificidade, acurácia (área sob a curva ROC), valores preditivos negativos e positivos das modalidades de imagem. Os resultados mostraram diferenças significativas nos valores médios do pixel para os três sistemas digitais, sendo que o Digora Optime® (194,46) apresentou o maior valor, seguido pelo DenOptix® (168,34) e pelo CDR Wireless® (109,44). Os sistemas CDR Wireless® e Digora Optime® obtiveram maiores valores de sensibilidade em relação às demais modalidades de imagem, sendo estatisticamente significativa a diferença entre esses sistemas e o filme radiográfico convencional (p=0,032). O Digora Optime® revelou o menor valor de especificidade e acurácia, o qual foi significativamente inferior ao do filme convencional (p<0,013). O sistema digital CDR Wireless® demonstrou desempenho semelhante ao filme radiográfico Insight® na detecção de cáries proximais incipientes. Por conseguinte, no tocante à qualidade da imagem, o novo CDR Wireless® pode ser uma alternativa viável para a utilização na clínica como método auxiliar de diagnóstico / Abstract: The aim of this study was to compare, both objectively and subjectively, the radiographic image quality of two storage phosphor plate systems (Digora Optime® e DenOptix®) with the results of the new complementary metal oxide silicon system, the CDR Wireless®. For the objective analysis, radiographs of an aluminum step wedge were obtained using the tree digital systems. This analysis was carried out by pixel density measurements using the appropriate tool from the EMAGO®/Advanced software. The data of pixel measurements was analyzed statistically using Kruskal-Walils test and Dunn multiple comparisons test (p<0.01). For the subjective analysis, under in vitro and standardized conditions, twenty phantoms with posterior human teeth were radiographed using one conventional film (Insight® Kodak) and the tree digital systems. Six radiologists recorded small approximal caries lesions on a 5-point confidence scale. The presence of caries was validated histologically. Two-way analysis of variance and post hoc t-test tested differences in sensitivity, specificity, accuracy, and positive predictive and negative predictive values. Differences were considered statistically significant when p<0.05. The results showed significant differences in the pixel density values for the three digital systems, with the Digora Optime® presenting the greatest values (194.46), followed by the DenOptix® (168.34) and CDR Wireless® (109.44). The two-way analysis of variance and post hoc t-tests demonstrated that CDR Wireless® and Digora Optime® had higher sensitivity than almost all other image modalities, significantly higher than conventional film. Digora Optime® had the lowest specificity and accuracy of all systems. Statistically significant difference existed in specificity and accuracy between this system and the conventional film (p<0.05), among the others systems there were no significant differences (p>0.05). The results suggest that the performance of the new CDR Wireless® was comparable to those of the digital systems and that of the Insight® film. Therefore, regarding to image quality, the new CDR Wireless® system may be used as an alternative, in clinical activities, as a diagnostic complementary method / Doutorado / Radiologia Odontologica / Mestre em Radiologia Odontológica

Page generated in 0.0704 seconds