Spelling suggestions: "subject:"desempenho térmica "" "subject:"esempenho térmica ""
101 |
Verificação dos valores dos coeficientes de convecção do ar no exterior de edifícios no estado da ParaíbaPorto, Eduardo Figueiredo 05 March 2007 (has links)
Submitted by Viviane Lima da Cunha (viviane@biblioteca.ufpb.br) on 2017-07-18T13:27:53Z
No. of bitstreams: 1
arquivototal.pdf: 2894407 bytes, checksum: 993603497277207e108988a17bd6d3b2 (MD5) / Made available in DSpace on 2017-07-18T13:27:53Z (GMT). No. of bitstreams: 1
arquivototal.pdf: 2894407 bytes, checksum: 993603497277207e108988a17bd6d3b2 (MD5)
Previous issue date: 2007-03-05 / This research investigated and analysed the characteristics and peculiarities of wind flowing
that take place in the state of Paraiba in order to verify the local values for the air coefficients
of external convection (hc’s), based in non-dimensional numbers like Prandlt, Reynolds and
Nusselt, and empirical correlations as suggested by Hilpert. These correlations are widely
used and the results demonstrate that the verified values significantly differ from the ones
currently recommended by the Brazilian norms concerning the thermal performance of
buildings and the basic parameters of projects for central air-conditioners. The results
highlighted the need to review these coefficients and take into consideration the
interrelationship between the standards of local ventilation and construction regulations when
calculating the thermal conditioning of buildings in order to minimize environmental impact
and improve energy performance of buildings, which will reduce costs. / Este trabalho investigou e analisou as características e as condições de escoamento dos ventos
que ocorrem no estado da Paraíba, a fim de determinar valores locais para os coeficientes de
convecção do ar externo (hc’s), com base nos números adimensionais de Prandlt, Reynolds e
Nusselt, e correlações empíricas com as sugeridas por Hilpert, que são largamente utilizadas,
cujos resultados demonstraram que os valores verificados diferem significativamente dos
valores atualmente recomendados palas Normas Brasileiras referentes ao desempenho térmico
de edificações, e aos parâmetros básicos de projeto de centrais de ar-condicionado,
conduzindo à necessidade de se reverem tais coeficientes e considerarem as inter-relações
entre o padrão de ventilação local e o de ocupação do solo, quando do cálculo de
acondicionamento térmico de edifícios, para se minimizar os impactos ambientais, otimizar o
desempenho energético de edificações, aumentando a economia de energia reduzindo custos.
|
102 |
A Influência do sombreamento e da absortância da envoltória no desempenho térmico e energético de edificações residenciais multipavimentos na cidade de João Pessoa-PB / The influence of shading and absortance of the envelope in the thermal and energy performance of residential buildings in João Pessoa-PBMartins, Lúcia Helena Aires 30 September 2013 (has links)
Made available in DSpace on 2015-05-14T12:09:28Z (GMT). No. of bitstreams: 1
arquivototal.pdf: 11490325 bytes, checksum: c5db739b54c8a079086312556753c528 (MD5)
Previous issue date: 2013-09-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Given the importance of adaptation of the building to the climate in search of more
thermally and energy efficient buildings, this study evaluates the influence of shading devices
and solar absorption coefficient of the envelope in the thermal and energy performance of
residential buildings located in the Manaíra, João Pessoa-PB , through computer simulations,
using the DesignBuilder program. The work involved the development of a methodology for
the identification of the main characteristics of residential buildings in urban cutout study.
Were analyzed 25 buildings with respect to: frequency of occurrence of numbers of floors,
terrain and edification shape, area of apartments, percentage area of window and of wall in
the facades, facade orientation, existence of elements of sun protection and constructive
characteristics general. Based on the data collected, a representative model of constructive
reality was elaborated, called predominant typology and used as the base case in the
simulations. One set of typologies was simulated, determined from alterations constructive
variables such as solar protection and absorption coefficient of the envelope, as well as, the
urban variable surroundings obstruction. The analysis variables considered were the
temperature of the internal air, solar gain through opaque and transparent closings and load
required for cooling. Was observed that the shading caused in the area around contributes to
a reduction in internal temperature and solar gain, but the balance is not always favorable,
some models analyzed presented an increase in solar gain by opaque closings. Just like the
density of surrounding area can elevate the air temperature and energy consumption in
domestic environments. The use of the shutter openings resulted in better thermal and
energy performance, higher than the adoption of low absorption coefficient ( = 0.20). / Diante da importância da adequação da edificação ao clima em busca de edificações
mais eficientes termicamente e energeticamente, este trabalho avalia a influência dos
dispositivos de sombreamento e do coeficiente de absorção solar da envoltória no
desempenho térmico e energético de edifícios residenciais multipavimentos localizados no
bairro de Manaíra, município de João Pessoa-PB, através de simulações computacionais,
utilizando o programa DesignBuilder. O trabalho compreendeu o desenvolvimento de uma
metodologia para o levantamento das principais características de edifícios residenciais
multipavimentos no recorte urbano em estudo. Foram analisados 25 edifícios com relação à:
frequência de ocorrência de números de pavimentos, forma do terreno e da edificação, área
dos apartamentos tipo, percentual de área de janela e de parede nas fachadas, orientação
das fachadas, existência de elementos de proteção solar e características construtivas
gerais. Com base nos dados levantados, um modelo representativo da realidade construtiva
foi elaborado, denominada de tipologia predominante e utilizada como caso base das
simulações. Um conjunto de tipologias foi simulado, determinado a partir de alterações de
variáveis construtivas, como proteção solar e coeficiente de absorção da envoltória, assim
como, a variável urbana obstrução do entorno. As variáveis de análise consideradas foram a
temperatura do ar interna, o ganho solar através dos fechamentos opacos e transparentes e
a carga necessária para resfriamento. Observou-se que o sombreamento provocado pelo
entorno contribui para a redução da temperatura interna e ganho de calor, porém nem
sempre o balanço é favorável, alguns modelos analisados apresentaram um aumento no
ganho solar pelos fechamentos opacos. Assim como, o adensamento do entorno, pode
elevar a temperatura do ar e o consumo de energia nos ambientes internos. O uso da
veneziana nas aberturas resultou no melhor desempenho térmico e energético, superior à
adoção de baixo coeficiente de absorção (=0,20).
|
103 |
Teoria Construtal e desempenho térmico de Trocadores de Calor Solo-ArBrum, Ruth da Silva January 2016 (has links)
Trocadores de Calor Solo-Ar (TCSA) são dispositivos usados para melhorar o condicionamento térmico de ambientes construídos. Eles funcionam através da ventilação do ar por um ou mais dutos enterrados, utilizando o solo como fonte ou sumidouro de calor. Em virtude da defasagem entre as temperaturas do ar e das camadas superficiais da Terra, é possível resfriar o ar no verão e aquecê-lo no inverno. Seus princípios de operação baseiam-se na mecânica dos fluidos e transferência de calor, áreas onde a teoria Construtal tem sido usada para melhorar o desempenho, ou reduzir imperfeições, de vários sistemas térmicos, após uma estratégica análise de suas geometrias (ou de seu design), também chamada de método Design Construtal que se fundamenta na lei construtal. Dessa lei, projetos em engenharia devem começar, por exemplo, descobrindo as arquiteturas que facilitam o escoamento entre uma fonte pontual e um volume, ou vice-versa. Explorando esses conceitos para TCSA, onde a corrente é o calor que flui entre os dutos e o solo, esta tese objetiva centralmente avaliar o desempenho térmico desses dispositivos em função de possíveis desenhos de suas estruturas. Particularmente, isso foi feito: (1) usando um duto e variando seu diâmetro e vazão de ar; (2) inserindo novos dutos, até um total de cinco, mantendo a vazão de ar constante, e estudando diversas disposições geométricas. Numericamente, foram empregados dois modelos testados e validados a partir de dados experimentais, que foram simulados no código comercial de dinâmica dos fluidos computacional, FLUENT, o qual baseia-se em métodos de volumes finitos. As geometrias e malhas foram geradas no software GAMBIT. Dos resultados numéricos, esta tese também avançou desenvolvendo novos modelos para o conceito de potencial térmico instantâneo, que é uma medida das diferenças de temperatura entre a saída e a entrada dos dutos de TCSA. Descobriu-se que estes modelos podiam ser simplificados em termos de funções senoidais, facilitando análises e definições analíticas subsequentes, criando um quadro resumo para grandes volumes de dados simulados. Das avaliações dos resultados nos estudos com um duto, foram encontradas faixas para a obtenção de rendimentos térmicos anuais estimados em pelo menos 80%, com mudanças no diâmetro e/ou vazão do ar. Analisando múltiplos dutos, foram reveladas melhorias significativas de rendimento com: (1) o aumento no número de dutos; (2) a redução, até certos limites, da razão entre os espaçamentos verticais e horizontais entre eles; (3) a ampliação da razão entre o volume da instalação e o volume do domínio computacional. Destaca-se, ainda, que em todos os casos foram calculados balanços energéticos, com a estimativa das taxas (e quantidade) de calor trocado, bem como da energia elétrica consumida pelos ventiladores, mostrando sua viabilidade no condicionamento de ar com redução do consumo de energia elétrica. / The Earth-Air Heat Exchangers (EAHE) are devices used to improve the thermal conditions of built environments. They work by blowing the air inside buried ducts to use the soil as heat source or sink. Due to a phase difference between the air and ground temperatures, it is possible to cool the air in the summer and heat it in the winter. These operating principles are based on the areas of fluid mechanics and heat transfer, where the Constructal theory has been used to improve the performance, or reduce imperfections, of several thermal systems, after a strategic evaluation of their geometries (or their design), also called Constructal Design method, which is anchored by the constructal law. From this law, engineering projects should begin, for example, finding the architectures which ease the flow between a source point and a volume, or vice versa. Bringing these concepts to EAHE, where the current is the heat which flows between the ducts and the soil, this thesis mainly aims to assess the thermal performance of EAHE due to possible designs of their layouts. Particularly, this was done by: (1) adopting one duct and varying its diameter and/or the air flow; (2) using up to five ducts, keeping the air flow constant, and studying various geometric shapes. Numerically, two models were used, which have been tested and validated from experimental data, and the simulations were done in the CFD software FLUENT, which is based in the finite volume methods. The geometries and meshes were generated by the software GAMBIT. From the numerical results, this thesis also pursued developing new models for the concept of the instantaneous thermal potential, which is a measure of the temperatures differences between the ducts outlet and inlet. It was found that these models can be simplified in terms of sinusoidal functions, helping analysis, definitions, and creating a framework to summarize large volumes of simulated data. From the evaluation of the data in the studies with one duct, ranges for changes in their diameter and/or air flow were found to obtain at least 80% of estimated annual efficiency. Analyzing multiple ducts, significant improvements in efficiency were also obtained by: (1) increasing the number of ducts; (2) reducing, to some extent, the ratio between their vertical and horizontal spacings; (3) increasing the ratio between the installation volume and the computational domain. It should also be highlighted that in all cases the energy balances were computed, to find the rates (and amounts) of exchanged heat, as well as the electric energy consumed by the fans, showing the economic viability of using EAHE as devices for air conditioning.
|
104 |
Desempenho termoenergético de edificações industriaisLacchini, André Stein January 2010 (has links)
O presente trabalho apresenta os resultados de estudo realizado através da utilização do programa computacional EnergyPlus para verificação do desempenho termoenergético de edificações industriais. O objetivo da dissertação é sistematizar resultados de horas de conforto geradas pelo frio ou pelo calor em um modelo computacional, através da modificação de parâmetros físicos, classificando-os em níveis de desempenho, como forma de melhorar as condições ambientais e de consumo energético de edificações industriais. Para o entendimento do estudo, a revisão bibliográfica apresenta conceitos que definem os seguintes temas: conforto térmico, trocas térmicas e termorregulação humana, balanço energético, variáveis que influenciam no conforto térmico, voto médio previsto, e zona de conforto. A metodologia apresenta o programa computacional utilizado para realizar as simulações, bem como o modelo computacional proposto. Após, são apresentadas pesquisas sobre técnicas de modificação de materiais construtivos, como forma de alterar as condições térmicas do ambiente. Para a análise são comparados os valores obtidos de temperatura de bulbo seco, dentro de faixa de conforto proposta, para obtenção de resultados de horas de desconforto. Os resultados demonstraram que a variação dos materiais construtivos que compõem a envoltória de uma edificação altera de forma considerável as condições térmicas ambientais. Por fim, a partir de uma discussão técnica sobre os resultados numéricos obtidos, é proposta uma planilha de avaliação do desempenho de edificações industriais. / This thesis presents the results of study realized using the software Energyplus, to verify thermal and energy performance of industrial buildings. The aim of this study is systematize discomfort hours results generated by cold or heat in a computer model, by the modification of physical parameters, classifying in performance levels, to improve the environment and energy consumption conditions of industrial buildings. Therefore, the literature review was based on the following fundaments: thermal comfort, thermal changes, energy balance, thermal comfort variables, predicted mean vote, and comfort zone. The methodology presents the software used to realize the simulations, as well the computer model proposed. After, the thesis presents research about constructive materials modification techniques, to alter the thermal environment. The dry temperature results obtained, in a comfort range suggested, are compared to obtain the discomfort hours results. Results showed that the constructive materials variation alter considerably the environment thermal conditions. Conclusively, after a technical discussion about the numerical results obtained, is suggested na assesment method to verify the thermal and energy performance of industrial buildings.
|
105 |
O desempenho térmico de um sistema de cobertura verde em comparação ao sistema tradicional de cobertura com telha cerâmica. / The thermal performance of green roof system in comparison to the traditional ceramic tile roof system.Iara Lima Ferraz 29 March 2012 (has links)
As coberturas verdes fazem parte da arquitetura vernacular há séculos como solução para regulação térmica das edificações, retardando a transferência de calor para o ambiente interno e, no inverno, retardando as perdas de calor dos ambientes internos para o exterior da edificação (International Green Roof Association - IGRA). Em se adotando cobertura verde em edificações supõe-se haver economia no consumo de energia para se obter condições de conforto térmico nos ambientes. Baseado nessa suposição foi realizada uma pesquisa experimental onde, por meio de um estudo comparativo entre dois tipos de cobertura: a verde e a de telhas cerâmicas comprovou-se o potencial de economia de energia. A análise do comportamento térmico das coberturas verdes foi realizada por meio de coleta de dados de variáveis ambientais, durante um período de 10 meses, de um protótipo instrumentado, construído no Departamento de Engenharia de Construção Civil da Escola Politécnica da USP, São Paulo. Os dados levantados foram comparados com os dados de um segundo protótipo de mesmas dimensões e igualmente instrumentado, com cobertura cerâmica, sob as mesmas condições ambientais. A comparação dos resultados e análises em dias e episódios representativos de cada estação comprovaram a eficiência das coberturas verdes para retardar o ganho térmico da edificação. Espera-se que os resultados sejam incentivadores à larga aplicação dos telhados egetados, o que trará diversas vantagens para população. / Green roofing is been a part of the vernacular architecture for centuries as solution for constructions thermal regulation. It is known that they delay the heat transfer from the outside to the inside of the building, and during winter, they delay the heating loss from the inside to the outside of the building (International Green Roof Association - IGRA). By adopting green roofs in buildings, one assumes that there is economy in energy consumption to obtain conditions of thermal comfort in inner environments. Based on this assumption, an experimental research was accomplished where, through a comparative study between two types of roofing systems: green and ceramics, it was determined this energy saving potential of green roofs. The analysis of the green roofing thermal behavior was realized through data collection of environmental variables, during the period of ten months, from an instrumented prototype constructed at the Polytechnic School of the University of São Paulo, São Paulo. The collected data was compared to those of a second prototype with the same dimensions and equally instrumented, with ceramics roofing, under the same environmental conditions. The data comparison and analysis of specific days in each season, proved the green roof efficiency on retarding the building thermal gain. One expects that the results will encourage the application of green roofs, which will bring several advantages to the population.
|
106 |
DESEMPENHO TÉRMICO DE HABITAÇÕES UNIFAMILIARES DE INTERESSE SOCIAL COM PAREDES DE CONCRETO ARMADO NA ZONA BIOCLIMÁTICA 2 BRASILEIRA / THERMAL PERFORMANCE OF SINGLE-FAMILY HOUSING OF SOCIAL INTEREST MADE WITH CONCRETE WALLS IN BRASILIAN BIOCLIMATIC ZONE 2Carvalho, Paula Pereira 18 September 2012 (has links)
This research aims to evaluate the thermal performance of housing built with the technology of reinforced concrete walls executed on site, for use in Brazilian Bioclimatic Zone 2. The study was conducted through in situ measurements of air temperature inside the four main types of single family housing of social interest of Zilda Arns allotment, in the town of Santa Maria-RS. Measurements were made in winter and summer, with the housing closed and also with the housing closed with sealing in places susceptible to air infiltration. The evaluations were made from the relationship between changes in internal temperatures and outdoor temperatures, and considering the influences of solar orientation and air infiltration, and internal thermal comfort through a comparative analysis of temperatures with ASHRAE (2004) limits. It was observed that the solar orientation has influence during winter and summer, however the air infiltration has little influence on thermal performance of housings. It was also observed that the building system provides good thermal performance for the summer period, but is not suitable to Bioclimatic Zone 2 during winter. As for thermal comfort, the housings presented cold discomfort for the whole period of winter and presented comfort in most of the analyzed summer period. / O presente trabalho tem como objetivo avaliar o desempenho térmico e o conforto térmico de habitações construídas com a tecnologia de paredes de concreto armado executadas no local, para uso na Zona Bioclimática 2 brasileira. O estudo foi realizado através de medições in loco da temperatura do ar no interior de quatro unidades com orientações solares predominantes de habitações unifamiliares de interesse social do loteamento Zilda Arns, na cidade de Santa Maria-RS. Foram feitas medições no inverno e no verão, com a casa fechada e também com a casa fechada com vedação nos locais passíveis de infiltração de ar. As avaliações foram .efetuadas a partir da relação entre as variações das temperaturas internas e das temperaturas externas, considerando ainda as influências da orientação solar e da infiltração de ar, e as condições de conforto térmico internas através de uma análise comparativa de temperaturas com valores limites da ASHRAE (2004). Foi observado que a orientação solar exerce influência nos períodos de inverno e verão, porém verificou-se que a infiltração de ar pouco influencia sobre o desempenho térmico das unidades. Observou-se ainda que o sistema construtivo apresenta bom desempenho térmico para o período de verão, porém não é adequado à Zona Bioclimática 2 no período de inverno. Quanto ao conforto térmico, as habitações apresentaram desconforto por frio em todo o período analisado de inverno e conforto na maior parte do período de verão.
|
107 |
Adaptação tecnológica para teto de habitação social: estudo de caso em Tuxtla Gutiérrez, Chiapas, México / Technological adaptation for roof of social dwelling: study case in Tuxtla Gutierrez, Chiapas, MexicoGabriel Castañeda Nolasco 17 October 2008 (has links)
O presente trabalho trata de um dos componentes da habitação social, o teto, que por suas características técnico-construtivas é o mais complexo dos seus componentes. A pesquisa foi desenvolvida em Tuxtla Gutiérrez, Chiapas, México, entre as atividades do programa 10x10, do projeto XIV.5 con techo, subordinado ao sub programa XIV, tecnologías para vivienda de interés social HABYTED de CYTED. Pelas atividades realizadas com o grupo técnico do programa citado, o objetivo principal foi desenvolver uma adaptação da tecnologia para teto Domozed ao contexto de Tuxtla Gutiérrez, Chiapas, México, orientada a melhorar a transferência tecnológica para habitação social. Esta tecnologia é utilizada no Peru e foi difundida em diversos países de América Latina, assim como muitas outras tecnologias cedidas pelos membros da equipe de trabalho do programa 10x10 con techo. As experiências vividas evidenciaram a necessidade de adaptação das tecnologias difundidas aos contextos selecionados, para sua melhor aceitação e funcionamento ou para sua realização. Partiu-se da hipótese que as tecnologias difundidas pelos membros participantes do programa 10x10, ao serem desenvolvidas para contextos específicos e pretender transferi-las a outros, sua apropriação ao novo contexto está condicionada por sua adaptação. O resultado foi o sistema de teto Domotej com a integração da análise de cinco variáveis priorizadas (processo construtivo, resistência mecânica, preço, desempenho térmico y aceitação social), que permitiram o desenvolvimento da adaptação; onde foi construído para sua avaliação, um protótipo experimental de moradia com o que se comprovou a viabilidade de construção e no contexto social do bairro Julio Cesar Ruiz Ferro, foi explorada a possibilidade de sua transferência. / The present work is about one of the components of the social dwelling, the roof, which is the most complex of the elements that make it a reality, due to its technician-constructive characteristics. The research project was developed in Tuxtla Gutierrez, Chiapas, Mexico, in the mark of activities of the program 10x10, of the project XIV.5 with roof, dependent on the sub program XIV, technologies for housing of social interest HABYTED of CYTED. For the achieved activities with the technical group of the mentioned project, the main objective was the adaptation of the roof Domozed to the study context. This roof technology is used in Peru and it has been diffused to different countries of iberoamerica, the same as many other technologies contributed by the members of the work team of the program 10x10 with roof. The lived experiences showed the adaptation need of the technologies diffused to the chosen contexts, for their best acceptance and function or simply for their realization. We started from the hypothesis that the transference of technologies diffused by the participant members of the program 10x10, when having been developed for specific contexts and intend to transfer them to other different contexts, their production, function, economic viability and social acceptance are conditioned by their adaptation, according to the necessity of making them appropriate and appropriable to the new context The result was the integration of the analysis of five prioritized variables (constructive process, mechanical resistance, price, thermal performance and social acceptance), what allowed the development of the adaptation, which was evaluated by the construction of an experimental prototype of dwelling proving the construction feasibility and in the social context of the neighborhood Julio Cesar Ruiz Ferro, the possibility of its transfer was explored.
|
108 |
Influência das propriedades térmicas da envolvente opaca no desempenho de habitações de interesse social em São Carlos, SP / Influence of the thermal properties of the opaque envelope in the thermal performance of social housing in São Carlos, SPMarques, Tássia Helena Teixeira 22 November 2013 (has links)
O objetivo principal desta pesquisa é analisar a influência da transmitância térmica da envolvente opaca (paredes e coberturas) e de outros parâmetros (cor das superfícies exteriores, ventilação natural e inércia térmica) que interferem no desempenho térmico de edifícios habitacionais de interesse social no clima da cidade de São Carlos, SP. Após levantamento de dados em construtoras e em órgãos públicos e privados ligados à habitações, foi selecionado um modelo unifamiliar térreo representativo desta tipologia para a análise. Como a pesquisa baseia-se em simulações paramétricas de desempenho térmico, inicialmente é feito um estudo sobre padrões de modelagem de habitações, identificando quais elementos são mais relevantes. Definidos os parâmetros da modelagem, procede-se à verificação dos valores máximos de propriedades da envoltória prescritos na norma NBR 15575 - Edificações habitacionais - Desempenho, e no regulamento RTQ-R: Regulamento técnico da qualidade para o nível de eficiência energética em edificações residenciais. Esta análise fornece indícios sobre a dificuldade em fixar valores desta propriedade para o fechamento opaco, uma vez que seu desempenho é definido pelas características da envoltória como um todo. Por fim, são realizadas três séries de simulações paramétricas, variando-se a transmitância térmica de paredes e coberturas, a inércia das paredes externas, as cores das superfícies expostas à radiação solar, o aproveitamento de ventilação natural e o uso de cargas internas (ocupação, iluminação e equipamentos). De acordo com os resultados, verifica-se que os melhores desempenhos térmicos estão associados a baixos valores de transmitância da envoltória opaca das habitações. Contudo, percebe-se que as faixas de valores tornam-se muito tênues quando analisa-se o desempenho conjunto dos parâmetros da envoltória. Conclui-se que há uma dificuldade no estabelecimento dos limites de transmitância sem considerar a totalidade de fatores que influem no comportamento térmico da habitação. Isso implica em uma análise conjunta dos materiais de paredes e coberturas e das cores das superfícies exteriores (transmitância, capacidade térmica e absortância). Além disso, critérios que considerem períodos de verão e inverno de acordo com predominância no clima da cidade e ainda outras características, como porcentagem de área envidraçada por orientação de fachada, devem ser considerados nas análises. / The main objective of this research is to analyze the influence of the thermal transmittance of the opaque envelope (walls and roof) and other parameters (color of the exterior surfaces, natural ventilation and thermal mass) that affect the thermal performance of social housing in the city of São Carlos, SP. After a research in public and private agencies related to housing construction, a single-family model was selected for the studies. First, it was carried out a study on parameters of the simulation models, identifying which elements are most relevant for the software. Defined the parameters of the models, it was made a verification of maximum values of properties of the envelope prescribed in the standard NBR 15575 - Residential Buildings - Performance and in the regulation RTQ -R: Technical Regulation for the quality level of energy efficiency in residential buildings. This analysis provides evidence of the difficulty of setting values of this property (U-value) for the opaque envelope, since its performance is defined by the thermal characteristics of the envelope as a whole. Finally, it was made three series of parametric simulations varying the thermal transmittance of walls and roofs, the thermal inertia of the external walls, the colors of the surfaces exposed to solar radiation, the use of natural ventilation and the use of internal loads (occupancy, lighting and equipment). The results indicate that the best performances are associated with low thermal transmittance of the opaque envelope of housing. However, it is clear that the ranges of transmittance values become very tenuous when we analyze the performance of all parameters of the envelope. We conclude that to establish limits of transmittance values results is an incomplete analysis of the thermal performance of the building. It is necessary to consider all factors that influence the thermal behavior of housing, which involves the analysis of the materials of walls and roofs and the colors of exterior surfaces. It is also important to adopt different criteria to consider summer and winter according to predominance in the climate of the city, and to consider in the analysis the percentage of glass area of the exterior envelope.
|
109 |
Conforto térmico e eficiência energética em hotéis econômicos / Thermal comfort and energy efficiency in Budget HotelsBuoro, Anarrita Bueno 17 March 2008 (has links)
Este trabalho busca avaliar a eficiência energética e o conforto, em ambiente climatizado artificialmente, dos Hotéis Econômicos de redes internacionais em São Paulo. A avaliação levada a cabo concentrou-se nas unidades habitacionais (UH) desses hotéis, principal produto oferecido por eles, possuidoras de sistema de ar condicionado (SAC), apesar das condições climáticas e das características do uso não determinarem essa necessidade. Com base nos levantamentos sobre as características dos Hotéis Econômicos, foi escolhido um hotel de uma rede internacional em São Paulo como estudo de caso. Nele, avaliou-se o desempenho térmico por meio de medições de temperatura e umidade relativa do ar em duas UH, durante cinco dias. As características físicas desse hotel foram utilizadas como modelo-base para as simulações computacionais realizadas no software TAS NG (2005). A partir dos resultados obtidos nas medições, definiram-se os critérios que seriam utilizados nas variações do modelo paramétrico, resultando em um total de sete cenários, com diferentes características como: vidros, cortina interna, taxa de ventilação e período determinado para ventilação. Levando-se em conta as condições climáticas da cidade de São Paulo e as características físicas e ocupacionais dos apartamentos, verificou-se que é possível obter conforto térmico sem o uso de SAC. Nessas condições, utilizou-se como critério de avaliação o modelo adaptativo da Norma ASHRAE 55 (2004). Os dados dos dias mais representativos de verão e inverno forma utilizados na análise dos ganhos de calor. Foi também avaliado, para o período de um ano, o consumo de energia elétrica do SAC, para resfriamento e aquecimento. Os resultados obtidos auxiliaram na proposição de recomendações de projeto para essa tipologia, buscando soluções que aprimoram o aproveitamento das condições naturais favoráveis para a obtenção de conforto térmico, possibilitando a redução do consumo de energia decorrente do SAC nestes ambientes. Para ilustrar algumas recomendações foram feitos estudos preliminares para as UH e para o pavimento tipo, considerando a integração do SAC com soluções de projeto de arquitetura que favoreçam o melhor desempenho energético de Hotéis Econômicos ou de qualquer categoria. / This work aims to evaluate the energy efficiency and comfort level, in airconditioned environments of budget hotels, from international chains, in São Paulo, Brazil. The evaluation was directed to the apartments which are the hotels main product featuring air conditioning, even though the climate conditions and usage profile dont determine its need. One hotel from an international chain was chosen as a case study based on research of budget hotels main features. The hotel had its thermal performance evaluated through air temperature and humidity measurements, in two apartments, for five days. Its physical characteristics were inputted into the TAS NG (2005) software as a base model for simulations. The measurements results defined the criteria used in the parametric model, resulting in a total of seven scenarios with different characteristics such as glass, internal shades, ventilating rates and period. Considering São Paulos climatic conditions, the physical and occupational characteristics of the apartments, it was verified that it is possible to reach thermal comfort without the use of air conditioning. The evaluating criterion used in these conditions was an adaptive model from the ASHRAE 55 (2004) Norm. Data from the most representative days of summer and winter were used in the analysis. There was also an evaluation of the energy consumption of the air condition- ing system, used for cooling and heating purposes, for a period of one year. The results favored the proposal for project recommendations for this typology, seeking solutions to improve the capacity to harness the favorable natural conditions to obtain thermal comfort, allowing for energy consumption reduction due to air conditioning. To illustrate the recommendations some preliminary studies were prepared for the apartments and pavement type, considering the integration of the air conditioning system with architectural design solutions that favor a better energy performance of budget hotels or of any other category.
|
110 |
Chapas metálicas perfuradas para proteção solar. Avaliação do desempenho térmico e luminoso / Perforated metal sheet for shading. Assessment of solar-optical performanceMinioli, Alda Regina Bueno 16 April 2014 (has links)
Neste trabalho é realizada a avaliação do desempenho solar e luminoso de chapas metálicas com diferentes padrões de perfurações empregados para proteção solar na envoltória das edificações. Foram ensaiadas experimentalmente as transmitâncias solar e luminosa em diversos ângulos de incidência de chapas metálicas, chapas expandidas e telhas metálicas, com ou sem pintura, planas ou com conformação espacial. Avaliou-se a relação entre a transmitância e % de perfuração da amostra para incidência da radiação em variadas alturas e azimutes solares, comparou-se o comportamento solar e luminoso de cada amostra e entre amostras com características semelhantes. As normas ASTM E972 Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight e ASTM E1084 Standard Test Method for Solar Transmittance (Terrestrial) of Sheet Materials Using Sunlight foram adotadas para medições de campo das amostras. Os resultados mostram que, para todas as amostras, as transmitâncias solar (TS) e luminosa (TL) na perpendicular se assemelham a % de perfuração da amostra; para ângulos diferentes da normal há uma redução conforme a altura solar diminui e que quanto maior for o furo em relação à espessura, menor será a redução. TS/TL decresce conforme a altura solar diminui, exceto para as telhas. Em relação à variação de azimute, para chapas perfuradas sem acabamento ou pintadas, os valores de TS e TL se mantêm praticamente iguais, enquanto que para chapas expandidas e telhas os valores variam. Para as amostras pintadas, TS e TL das amostras com cores claras são maiores do que das amostras com cores médias que por sua vez são maiores do que as amostras com cores escuras. A partir destes resultados e da elaboração da ficha de aplicação dos resultados para variados ângulos, no âmbito do projeto de arquitetura, contribui-se para o emprego apropriado deste tipo de material, além de complementar informações técnicas pouco disponíveis no mercado. Além disso, os dados medidos em campo podem servir de validação para modelagem computacional para uma variação maior de ângulos, e na avaliação de ambientes projetados ou construídos, os dados coletados, em especial os ângulos diferentes da incidência normal, podem ser usados em simulação energética ao longo do ano. / This research focuses on the evaluation of solar and optical performance of metal sheets with different patterns of perforations used as shading devices in the building\'s envelope. Solar and light transmittance were experimentally tested at normal and off-normal incident angles of samples of perforated metal sheet, expanded metal sheets and perforated tile, with or without painting, flat or volumetric shape. The relationship between % perforation of sample and transmittance for off normal angle incidence (height and azimuth) was evaluated. Solar and optical results were correlated for each sample. Samples with similar characteristics such as perforation, painting, hole dimension were compared. ASTM E 972 Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight and ASTM E 1084 Standard Test Method for Solar Transmittance (Terrestrial) of Sheet Materials Using Sunlight were adopted for field measurements of the samples. The results show that for all samples, the solar transmittance (TS) and light (TL) perpendicular to the sample is similar to % perforation; for off normal angles there is a reduction as the solar altitude decreases and that the higher the hole relative to thickness, the smaller the reduction. TS / TL decreases as solar height decreases, except for the tiles. Regarding the change in azimuth for perforated sheets with or without painting, the values of TL and TS remains practically the same, whereas for expanded metal and tiles values vary. For the painted samples, TS and TL bright color of the samples are higher than the intermediate color samples which are in turn higher than the samples of dark colors. From the results achieved and with the development of the application table to diferente incident angles, within the architecture field, these results provide information for the appropriate use of such material, plus some additional technical information available in the market. Furthermore, the data measured in the field can serve as validation for computational modeling to a wider range of angles, and also it could be used in buildings\' energy simulations.
|
Page generated in 0.0886 seconds