• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modélisation spatio-temporelle de l’évolution de la dengue en lien avec des prédicteurs environnementaux dans le département de Méta en Colombie entre 2011 et 2019

Berkat, Rawda 12 1900 (has links)
Contexte : La dengue est une fièvre ayant pris davantage d’ampleur dans plusieurs régions du monde à climat tropical, dont le département Méta en Colombie, un lieu endémique dans la dernière décennie. Sachant que la propagation de cette maladie est entièrement dépendante des sites de reproduction du vecteur de transmission Aedes, l’investigation de prédicteurs environnementaux les affectant nous semblait pertinente d’un point de vue épidémiologique. Notre étude vise des retombées sur un plan de surveillance de santé publique et l’élaboration de programmes basés sur des observations temporelles et spatiales. Objectifs : Décrire la distribution spatio-temporelle de la dengue dans les 29 municipalités de Méta selon des prédicteurs environnementaux, soit les précipitations, la température ambiante, la température du point de rosée et la pression au niveau de la mer dans le cadre d’une étude écologique. Méthodes : Des données de surveillance SIVIGILA, de télédétection ainsi que de recensement DANE des 29 municipalités du département de Méta entre 2011 et 2019 ont été utilisées pour étudier l’association entre la dengue et les prédicteurs environnementaux. La modélisation de ces associations a été effectuée à l’aide d’un modèle de Markov cachés à changement de régime. Résultats : Des associations positives importantes ont été détectées entre les précipitations et l’incidence de la dengue atteignant des risques relatifs élevés (RR=1.97 à El Calvario à un décalage de 5 semaines ; RR=1.61 à San Juanito à un décalage de 20 semaines). La température ambiante et la température du point de rosée ont suivi en matière de pertinence n’excédant pas des RR de 1.11 pour la maladie. Or, la pression au niveau de la mer n’a pas présenté des résultats concluants. Selon les différents aspects étudiés dans les nombreuses cartes de ce mémoire, nous avons observé une dépendance géographique répétée à l’ouest du département. Conclusion : Nos conclusions recommandent qu’une attention particulière de la santé publique doit s’imposer quant à la prévention de la dengue en saison pluvieuse dans le Meta. Les hausses des valeurs de température ambiante et de la température du point de rosée peuvent expliquer certaines augmentations de l’incidence et incitent donc à la surveillance de ces paramètres également. À noter que nos résultats ont possiblement pu être influencés par un biais d’information et un biais de confusion. / Context: Dengue is a type of fever that has significantly spread in several regions of the world characterized by a tropical climate, including the Meta department in Colombia, which seemed to be an endemic place in the last decade. Knowing that the spread of this disease is entirely dependent on the reproduction sites of the Aedes transmission vector, the study of environmental predictors affecting those sites seemed relevant from an epidemiological point of view. Our study aims to add to the knowledge that can be used for public health surveillance and program elaboration based on temporal and spatial observations of dengue patterns within the region. Objectives: To describe the spatiotemporal distribution of dengue fever in the 29 municipalities of Meta according to its environmental predictors (i.e. precipitation, ambient temperature, dew point temperature and pressure at sea level) within the framework of an ecological study. Methods: SIVIGILA surveillance, remote sensing and DANE census data from 29 municipalities in the Meta department between 2011 and 2019 were used to study the association between dengue fever and environmental predictors. These associations were modeled using a regime-switching hidden Markov model. Results: Significant positive associations were detected between rainfall and dengue incidence reaching high relative risks (RR=1.97 in El Calvario at a 5-week lag; RR=1.61 in San Juanito at a 20-week lag). Ambient temperature and dew point temperature followed in terms of relevance not exceeding RRs of 1.11 for disease. However, pressure at sea level did not show conclusive results. According to the different aspects studied in the many geographical maps of this thesis, we observed a repeated geographical dependence in the west of the department. Conclusion: We recommend that special public health attention should be given to the prevention of dengue fever in the rainy season in Meta. Increases in ambient temperature values and dew point temperature may explain some increases in incidence and therefore prompt monitoring of these parameters as well. It should be noted that our results may have been influenced by an information bias and confusion bias.
2

Klimatförhållanden och energianvändning på Gränby ishall : Hur Uppsala kommun Arenor och fastigheter AB kan förbättra klimatförhållandena och sänka energianvändningen i Gränby ishall

Kylhed, Ebba January 2024 (has links)
This report intends to investigate climate conditions and energy consumption in Gränby Ice rink in Uppsala.Today, Gränbyhallen faces a potential renovation project to modernize and improve what was initially intended as a temporary hall that was inaugurated in 1974.In 2021, the property was taken over by the Uppsala municipality Arenor och Fastigheter AB from having previously been owned by the municipality. Since then, Arenor och Fastigheter has worked to modernize its facilities and in this way also work to improve the energy consumption required by the operation of the Gränby ice rink and also examine the indoor climate conditions in the building.The idea is to make the climate more pleasant for the visitors, and therefore making it less cold and barren temperaturevise by separating the ventilation from the ice and bleachers so that these can be controlled individually. The hope is to be able to reduce energy consumption with such a solution by seeing if the facility has heat leakage from the outside and how moisture can be managed in the facility to be kept at a more even level throughout the year and during the day.For the report, weather data was obtained from SMHI and then compiled and compared with temperatures and energy consumption from sorption dehumidifiers and the plant total to locate current deficiencies but also how to potentially address these to lower energy consumption.Analysis of the data was also done for the outdoor temperature which was set against the indoor temperature and then also the difference between the two to see the difference anddemonstrate how well insulated the facility is. On average over the entire time investigated, there was only +1°C difference between outside and inside, which gives an indication that the insulation in the facility needs to be reviewed and improved both outside and inside as there are large leaks in the facility with open surfaces and only metal doors that separate warm surfaces from cold.The analysis also suggests that the dehumidifier should be changed to regulate according to the dew point temperature from regulating according to the relative humidity as the dew point changes less over time and is less affected by the amount of water in the air which changes from hour to hour and is also affected by the outdoor climate when doors are opened and closed to the facility. / Denna rapport avser att undersöka klimatförhållanden och energiförbrukningen i Gränby ishall i Uppsala. Idag står Gränbyhallen inför ett potentiellt renoveringsarbete för att modernisera och förbättra till en som till en början var tänkt som en provisorisk hall från 1974. 2021 togs fastigheten över av Uppsala kommun Arenor och Fastigheter AB från att tidigare varit kommunägt. Arenor och Fastigheter har sedan dess arbetat med att modernisera sina fastigheter och på så sätt även arbeta med att förbättra energiförbrukningen som driften i Gränby ishall kräver och även undersöka klimatförhållandena inomhus. Tanken är att göra klimatet för åskådarna mer behagligt att vistas i från dagens kalla och karga temperaturer genom att separera läktarens ventilation och avfuktning från isens, så att dessa kan styras enskilt och därmed ha olika klimat. Förhoppningen är att med en sådan lösning kunna minska energiförbrukningen genom att se ifall anläggningen har värmeläckage från utsidan samt hur fukt kan hanteras i anläggningen för att hållas på en mer jämn nivå över året och under dagen. Till rapporten har väderdata hämtats från SMHI och sedan sammanställts och jämförts med temperaturer och energiförbrukning från sorptionsavfuktare och anläggningens total för att lokalisera nuvarande brister, men även hur man kan potentiellt åtgärda dessa för att sänka energiförbrukningen. Analys av data gjordes även för temperaturen utomhus mot temperaturen inomhus och då differensen av de två för att se skillnaden och påvisa även hur väl isolerad anläggningen är. I genomsnitt över hela tiden som undersöktes skildes det bara +1°C mellan ute och inne, vilket ger indikation på att isoleringen i anläggningen behöver ses över och förbättras både ute och inne då det finns stora läckage i anläggningen med öppna ytor och endast plåtdörrar som separerar varma ytor från kalla. Analysen tyder även på att avfuktaren bör ändras till att reglera efter daggpunktstemperaturen i stället för som nu efter relativa luftfuktigheten. Daggpunkten ändras mindre över tid och påverkas mindre av luftens vattenmängd, som ändras från timme till timme och som påverkas även av utomhusklimatet när dörrar öppnas och stängs till anläggningen.
3

Vliv obtokového součinitele na návrh a geometrii přímého výparníku pro chladící jednotku / The Effect of the Bypass Factor on Design and Geometry of the Evaporator for the Cooling Unit

Vytasil, Michal January 2016 (has links)
Diploma thesis focuses on effect of the bypass factor on design and geometry of the evaporator for the cooling unit of data centre. Effect of the bypass factor on individual design parameters is solved in detail. All dependendecies are captured by using graphs in which s placed a cement on that parameter. In part C, mathematical and physical solutions are demonstrated calculations and processes leading to the design of the exchanger. In the end, evaluation of the calculations is done and there is also showed possible improvements for the practise.

Page generated in 0.0669 seconds