• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 259
  • 169
  • 25
  • 16
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 563
  • 563
  • 168
  • 166
  • 166
  • 97
  • 84
  • 82
  • 82
  • 79
  • 79
  • 71
  • 65
  • 55
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
311

Estudo tomográfico, ultrassonográfico e dopplerfluxométrico renal de jabutis-piranga (Chelonoidis carbonarius, Spix,1824)

Dadalto, Carmel Rezende January 2017 (has links)
Orientador: Maria Jaqueline Mamprim / Resumo: O jabuti-piranga (Chelonoidis carbonarius) é o quelônio mais criado em cativeiro no país, principalmente por ser considerado um animal de companhia, e por isso representa uma grande casuística no atendimento clínico de animais silvestres. O exame físico da espécie é limitado pela presença de casco e plastrão. A análise ultrassonográfica celomática em modo B, Doppler colorido e espectral renal, associado ao exame tomográfico teve por objetivo fornecer valores de referência que auxiliarão na investigação de doenças renais, uma vez que, são escassos os relatos pretéritos de normalidade renal de jabuti-piranga. Foram avaliados 10 jabutis hígidos, sob contenção química. Na avaliação ultrassonográfica modo B os rins apresentaram formato triangular, sem definição cortico-medular e de pelve renal, hipoecogênicos ao fígado e intensamente vascularizados. O eixo renal longitudinal obteve média de 4,21 cm. A média do índice de resistividade (IR) das artérias intrarrenais foi de 0,63 e 0,60 para os rins esquerdo e direito, respectivamente. Na avaliação tomográfica os rins apresentaram-se em topografia dorsocaudal da cavidade celomática e cranial ao acetábulo. A densidade média pré-contraste foi de 45,9 HU e pós-contraste 202,05 HU. A ultrassonografia e tomografia computadorizada se mostraram técnicas eficientes na avaliação renal de jabutis-piranga, sendo seu emprego, na rotina clínica de animais selvagens, promissor. / Mestre
312

Avaliação da faringe de pacientes portadores de apneia obstrutiva do sono, por meio da tomografia computadorizada multislice obtida em vigília e durante o sono / Evaluation of the pharynx in patients with obstructive sleep apnea with multislice computed tomography during awake and asleep

Ula Lindoso Passos 23 September 2011 (has links)
Introdução: A síndrome da apneia obstrutiva do sono (SAOS) tem sido cada vez mais estudada devido à sua prevalência e relação com problemas graves de saúde, como o aumento do risco de patologias cardiovasculares. O padrão-ouro para diagnóstico é a polissonografia (PSG), mas este método não fornece dados anatômicos da faringe dos pacientes. Objetivos: Avaliar, por meio de imagens de TC multislice (TCMS), o aspecto da faringe em indivíduos de um grupo controle e do grupo SAOS em vigília e durante o sono, observando as modificações sofridas nas estruturas faríngeas circunvizinhas e na coluna aérea; avaliar o comportamento faríngeo durante o ciclo respiratório nos indivíduos em vigília. Métodos: A amostra compreendeu 11 pacientes com SAOS grave, índice apneia/hipopneia maior que trinta, confirmados por PSG, e 7 indivíduos sem SAOS, controles, confirmados por PSG por Stardust, todos do sexo masculino. Os indivíduos foram submetidos a avaliação por TCMS com 16 canais (modelo Brilliance 16,Philips Medical Systems) e polissonografia simultânea. Os exames foram realizados com os indivíduos acordados e dormindo, em sono espontâneo. Foram realizadas aquisições volumétricas em ambos os estados (acordado e dormindo) e, posteriormente, avaliação das reformatações nos planos axiais, sagitais e das reconstruções em 3D. Foram realizadas medidas lineares e volumétricas: diâmetro mínimo anteroposterior e laterolateral, área mínima na orofaringe, retropalatal (RP) e retrolingual (RL), diâmetro transverso da língua, espessura da parede faríngea na região retropalatal, distância entre os ramos mandibulares, diâmetro anteroposterior da língua, comprimento e espessura do palato mole, espessura do tecido gorduroso subcutâneo na região submentoniana, distância MP-H (borda superior do hioide ao plano mandibular); volume da coluna aérea, volume das paredes faríngeas laterais, volume da gordura do espaço parafaríngeo e o volume da lingua. Resultados: As medidas significativamente menores encontradas no grupo SAOS, na região retropalatal, foram o diâmetro laterolateral e a área. Também houve diferença estatisticamente significativa nas medidas de espessura da língua, do palato, comprimento do palato, distância MP-H e ângulo mandibular. Foi realizado estudo comparativo entre as medidas lineares e volumétricas da faringe do grupo SAOS em estado de vigília e sono. Houve redução dos diâmetros retropalatal anteroposterior e laterolateral, da área e do volume da via aérea entre os estados acordado e dormindo. No grupo controle foram realizadas medidas lineares e volumétricas, porém não houve diferença significativa entre os diferentes estados. A variação da medida da área na região retropalatal foi significativa no grupo SAOS durante o estudo dinâmico. Conclusão: Em nossa amostra, as vias aéreas superiores de indivíduos do grupo SAOS diferem daquelas dos indivíduos do grupo controle. O grupo SAOS e o grupo controle sofrem modificações diferentes nas suas VAS, quando entram em estado de sono, de forma que as modificações do grupo SAOS são caracterizadas por mudanças significativas de medidas lineares e volumétricas, sugerindo maior suscetibilidade ao colapso faríngeo. O estudo dinâmico demonstrou que, na região retropalatal, indivíduos com SAOS são mais passíveis de colapso faríngeo. / Introduction: The obstructive sleep apnea syndrome (OSAS) has been increasingly studied because of the prevalence and relationship to serious healthy problems such as increased risk of cardiovascular diseases. The gold standard for diagnosis is polysomnography (PSG), but this method does not provide anatomical data of the pharynx of patients. Objectives: To evaluate the changes in upper airway and soft tissue structures surrounding the upper airway during wakefulness and sleep in patients with OSAS and a control group without OSAS. Methods: 11 patients with severe OSAS (apnea index > 30 event/hour) and 7 subjects without apnea and polysomnogram (Stardust) negative for OSAS were examined on a 16-channel multislice computed tomography. The exam was carried out with the patient awake and during spontaneous asleep, without any kind of sedation. The patients were monitored with a polysomnogram during the exam to assure the sleep and awaken state. Airway and soft-tissue 2-D measurements were performed in retropalatal and retroglossal level as well as, 3-D volumetric measurements. The measures were minimum anteroposterior and laterolateral diameter, the minimum area in the oropharynx in retropalatal and retroglossal levels, transverse and anteroposterior diameter of the tongue, pharyngeal wall thickness in RP, the distance between the mandibular branches, thickness and the length of the soft palate, the thickness of subcutaneous fat tissue in the submental region, MP-H distance (top edge of the hyoid to mandibular plane); volume of air column, volume of lateral pharyngeal wall, the volume of the parapharyngeal space fat, and the tongue volume. Results: Patients with OSAS had a small cross sectional area of retropalatal pharynx and the upper airway are significantly smaller when the patients were asleep. The measurements which presented significant decrease during sleep were the laterolateral and anteroposterior retropalatal diameter and minimal cross-seccional area. There was an inverse relationship between dimensions of lateral pharyngeal walls and the airway area, which was more pronounced during sleep. There was also a statistically significant difference in measures of the tongue thickness, palate thickness and length, MP-H distance and mandibular angle. There was a reduction of laterolateral, anteroposterior diameter, cross seccional area and upper airway volume, between awake and asleep states. Linear and volumetric measurements were performed in the control group but there was no significant difference between the different states. The variation of the cross seccional area in the OSAS group was significant during the dynamic study. Conclusion: The upper airway of subjects with severe OSAS differs from controls subjects. The OSAS group and the control group undergo different modifications in their upper airway after the sleep onset, and the changes of obstructive sleep apnea syndrome are characterized by significant changes of linear and volumetric measurements, suggesting greater pharyngeal collapsibility. There were significant differences in the patterns of dynamic airway motion between patients with and those without OSAS.
313

Quantificação da resoluçao do sistema SPECT-CZT através do uso da função de transferência modulada (MTF)

Zandona, Ednaldo Alexandre [UNESP] 22 February 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-02-22Bitstream added on 2014-06-13T20:10:26Z : No. of bitstreams: 1 000749206.pdf: 2362410 bytes, checksum: f4f84a869a32983e7c75a2cda7ba0e17 (MD5) / A medicina nuclear é uma especialidade médica que se ocupa de técnicas de imagem para observar o estado fisiológico dos tecidos ou órgãos de forma não invasiva, através da marcação de moléculas participantes desses processos, com isótopos radioativos, originando assim os chamados radionuclídeos. O SPECT é um equipamento que se utiliza de imagens planares, obtidas de vários ângulos ao redor do objeto de interesse, e, através de algoritmos computacionais, obtêm uma imagem tomográfica dessas projeções. Sua origem remete há aproximadamente cinquenta anos atrás, com criação da Câmara Anger (Hall Anger, 1964). Durante todo esse tempo, embora tenha havido alguma evolução, a estrutura dessas gama câmaras praticamente ficou Inalterada. Os constantes avanços em pesquisas empregando cristais semicondutores nos exames cintilográficos, bem como a necessidade do surgimento de novos sistemas detectores, compactos, com maior poder de resolução e alta sensibilidade conjugados a crescente preocupação mundial com a minimização das doses de radiação ionizante utilizadas nos exames diagnósticos e terapias, impulsionou o desenvolvimento de novos sistemas detectores. Recentemente, duas Grandes Empresas lançaram comercialmente novos sistemas de detecção para aquisições tomográficas em medicina nuclear, utilizando detectores do estado sólido, mais especificamente cristais de telureto de cádmio e zinco (CZT). Algumas vantagens desse tipo de detector são a melhora sensível da relação sinal/ruído, o aumento da resolução espectral e espacial, o que em suma, resultam numa maior nitidez das imagens obtidas. O emprego desses detectores abre novas perspectivas para os protocolos de imagem. Entretanto, devido a inúmeros fatores, os equipamentos ditos CZT estão focados na área cardiológica, e devido a características próprias requerem a reformulação dos protocolos de aquisição de imagem além daqueles destinados ao... / Nuclear medicine is a medical specialty that deals with imaging techniques to observe the physiological status of the tissues or organs noninvasively, by dialing molecules participating in this process, with radioactive isotopes, thus giving the so-called radionuclides. The SPECT is a device that uses planar images, taken from different angles around the object of interest, and, through computer algorithms, obtains a tomographic image of those projections. Its origin refers for nearly fifty years ago, with the creation of the Chamber Anger (Anger Hall, 1964). Throughout this time, although there has been some evolution, the structure of these gamma cameras was virtually unchanged. The constant advances in research employing semiconductor crystals in scintigraphic examinations, as well as the need for the creation of new detectors systems, compacts, higher resolution and high sensitivity; combined with growing worldwide concern with minimization of doses of ionizing radiation used in diagnostic tests and therapies, spurred the development of new detector systems. Recently, two large companies launched commercially new detection systems for nuclear medicine tomographic acquisitions, using solid-state detectors, specifically crystals of zinc and cadmium telluride (CZT). Some advantages of this type of detector are sensitive improvement of signal / noise ratio, increased spectral and spatial resolution, which in short, resulting in greater clarity of the images obtained. The use of these detectors opens news perspectives for imaging protocols. However, due to numerous factors, equipment said CZT are focused on cardiology area, and due to the inherent characteristics, require reformulation of image acquisition protocols beyond those intended for Quality Control
314

Elastografia Acoustic Radiation Force Impulse (ARFI) e Doppler na avaliação das glândulas adrenais de cães hígidos /

Fernandez, Stephanie. January 2016 (has links)
Orientador: Marcus Antonio Rossi Feliciano / Coorientador: Wilter Ricardo Russiano Vicente / Coorientador: Sofia Borin Crivellenti / Banca: Eliandra Antônia Pires Buttler / Banca: Lenadro Zuccolotto Crivellenti / Resumo: As glândulas adrenais exercem papel fundamental na manutenção da homeostasia tanto em humanos, como nos animais, logo a avaliação ultrassonográfica dessas glândulas deve ser rotina, uma vez que pode auxiliar no diagnóstico de uma dada afecção, principalmente o hiperadrenocorticismo, doença relativamente comum principalmente nos cães, cujo diagnóstico baseia-se na avaliação do eixo hormonal hipotálamo-hipófise-adrenal. Quanto às outras doenças, como neoplasias, cistos, hiperplasias, dentre outras, o diagnostico se torna desafiador, pois depende de métodos invasivos de alto risco. Logo, este estudo buscou a aplicabilidade de técnicas de imagem avançadas e não invasivas, como a elastografia ARFI (quantitativa e qualitativa) e a ultrassonografia Doppler, com o objetivo de determinar os valores de normalidade ainda não relatados. Os resultados obtidos na avaliação ultrassonográfica modo-B nos cães saudáveis, mostraram hipoecoica em relação a gordura adjacente, homogêneas, contorno liso, formato típico e dimensões dentro dos valores de normalidade. A avaliação Doppler determinou os índices vasculares da artéria frênico-abdominal da glândula adrenal esquerda: velocidade sistólica 31,34 ± 5,79 cm/s e velocidade diastólica 9,54±3,03 cm/s, e da glândula adrenal direita: velocidade sistólica: 34,25±8,18 cm/s e velocidade diastólica 10,72±3,75 cm/s. Portanto, este estudo conseguiu com êxito demostrar a aplicabilidade destas técnicas na avalição das glândulas adrenais, mostrando-se promis... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The adrenals glands have an important role in maintaining homeostasis in humans and animals, so the ultrasonography evaluation of these glands should be routine, since it may help in the early diagnosis of a particular condition, as hyperadrenocorticism, a relatively common disease mostly in dogs, whose diagnosis is based on the evaluation of the hypothalamic-pituitary-adrenal hormonal axis. Other diseases such as tumors, cysts, hyperplasia, among others, the diagnosis becomes challenging because it depends on high-risk invasive methods. Therefore, this study sought the application of advanced imaging techniques and non-invasive, such as elastography ARFI (quantitative and qualitative) and Doppler ultrasound, in order to determine normal values not reported yet. The results obtained in the ultrasound B-mode assessment in healthy dogs, were within the normal range. The Doppler evaluation determined the vascular indices of the phrenic-abdominal artery of the left adrenal gland: systolic velocity 31.34 ± 5.79 cm / s and diastolic velocity 9:54 ± 3:03 cm / s, and right adrenal gland: systolic velocity: 34.25 ± 8.18 cm / s speed diastolic 10.72 ± 3.75 cm / s, hitherto not described in the veterinary literature. Therefore, this study was able to successfully demonstrate the applicability of these techniques in adrenal glands, showing promise for the diagnosis aid conditions of the canine adrenals. / Mestre
315

Ruptura do ligamento cruzado cranial em cães : comparação dos meios de diagnóstico radiográfico, ultrassonográfico e por tomografia computadorizada /

Almeida, Mariana Ferreira de. January 2013 (has links)
Orientador: Maria Jaqueline Mamprim / Banca: Sheila Canevese Rahal / Banca: Cláudia Valéria Seullner Brandão / Banca: Ana Carolina de Campos Fonseca Pinto / Banca: Luciana Del Rio Pinoti Ciarlini / Resumo: A ruptura do ligamento cruzado cranial é considerada a causa mais frequente de claudicação de membro pélvico em cães. O presente estudo teve por objetivo comparar a contribuição dos exames: radiográfico, ultrassonográfico e por tomografia computadorizada no diagnóstico da ruptura do ligamento cruzado cranial em cães. No grupo de trabalho foram avaliados 25 cães que apresentaram claudicação do membro pélvico e suspeita de ruptura do LCCr, e para tanto esses animais foram submetidos à exames radiográfico, ultrassonográfico e por tomografia computadorizada com contraste negativo da articulação do joelho. O diagnóstico da ruptura do LCCr foi mais fácil nos quadros agudos, quando foi possível visibilizar sinais conclusivos da ruptura nas três modalidade de imagem. Nos casos crônicos as alterações degenerativas dessa articulação foram muito intensas obscurecendo a visibilização dos sinais característicos nas três modalidades, entretanto o exame ultrassonográfico apresentou melhor contribuição diagnóstica entre os demais e o exame por tomografia computadorizada mostrou-se mais sensível em detectar os sinais de doença degenerativa articular / Abstract: Rupture of the cranial cruciate ligament is considered the most common cause of hind limb lameness in dogs. The present study aimed to compare the contribution of examinations: radiographic, ultrasound and computed tomography in the diagnosis of cranial cruciate ligament rupture in dogs. In the working group were evaluated 25 dogs that showed lameness of the hind limb and suspected rupture of the CCL, and both these animals underwent radiographic, ultrasound and computerized tomography with contrast negative knee joint. The diagnosis of CCL rupture was easier to acute cases, when it was possible to visualize conclusive signs of rupture in the three imaging modality. In the chronic degenerative changes of this joint were very intense obscuring the visualization of characteristic signals in three modalities, however the ultrasound showed better diagnostic contribution among the rest and examination by computed tomography was more sensitive in detecting the signs of degenerative joint disease / Doutor
316

Using the Delphi technique to define the clinical competencies required by newly qualified diagnostic radiographers in South Africa

Davidson, Florence Elizabeth January 2006 (has links)
Thesis (MTech (Radiography))--Cape Peninsula University of Technology, 2006 / This research was performed to obtain consensus of opinion on the clinical competencies required of newly qualified diagnostic radiographers in South Africa in an attempt to improve alignment between educational practices, assessment practices and workplace requirements. Methods: The Delphi technique, an effective group communication process was employed to recruit a panel of experts representing the radiography profession in South Africa. Three rounds of structured questionnaires together with controlled feedback were sent to the panel members for comment. The same four point Likert scale was employed in all three rounds of the questionnaire. Consensus of opinion was predetermined at >75% agreement for each clinical competency. Results: Response rates for rounds I, 2 and 3 were: 84% (n=49), 78% (n=45) and 69% (n = 40) respectively. Of the 109 clinical competencies listed in the first round questionnaire, 94 (86%) achieved consensus as being necessary clinical competencies required of newly qualified diagnostic radiographers. The remainders were further investigated in terms of whether they should be excluded or included in role extension possibilities. An additional 22 clinical competencies were also suggested by the panel in round I and further developed in subsequent rounds
317

2D & 3D ultrasound systems in development of medical imaging technology

Eljaaidi, Abdalla Agila January 2016 (has links)
Thesis (MTech (Electrical Engineering))--Cape Peninsula University of Technology, 2016. / Ultrasound is widely used in most medical clinics, especially obstetrical clinics. It is a way of imaging methods that has important diagnostic value. Although useful in many different applications, diagnostic ultrasound is especially useful in antenatal (before delivery) diagnosis. The use of two-dimensional ultrasound (2DUS) in obstetrics has been established. However, there are many disadvantages of 2DUS imaging. Several researchers have published information on the significance of patients being shown the ultrasound screen during examination, especially during three- and four-dimensional (3D/4D) scanning. In addition, a form of ultrasound, called keepsake or entertainment ultrasound, has boomed, particularly in the United States. However, long-term epidemiological studies have failed to show the adverse effects of ultrasound in human tissues. Until now, there is no proof that diagnostic ultrasound causes harm in a human body or the developing foetus when used correctly. While ultrasound is supposed to be absolutely safe, it is a form of energy and, as such, has effects on tissues it traverses (bio-effects). The two most important mechanisms for effects are thermal and non-thermal. These two mechanisms are indicated on the screen of ultrasound devices by two indices: The thermal index (TI) and the mechanical index (MI). These are the purposes of this thesis: • evaluate end-users’ knowledge regarding the safety of ultrasound; • evaluate and make a comparison between acoustic output indices (AOI) in B-mode (2D) and three-dimensional (3D) ultrasound – those measured by thermal (TI) and mechanical (MI) indices; • assess the acoustic output indices (AOI) to benchmark current practice with a survey conducted by the British Medical Ultrasound Society (BMUS); and • review how to design 2D and 3D arrays for medical ultrasound imaging
318

Desenvolvimento e construção de um fantoma homegêneo de mão para otimização de imagens radiográficas /

Pavan, Ana Luiza Menegatti. January 2014 (has links)
Orientador: José Ricardo de Arruda Miranda / Coorientador: Diana Rodrigues de Pina / Banca: Paulo Mazzoncini de Azevedo-Marques / Banca: Trajano Sardenberg / Resumo: A Radiologia Computadorizada (CR - do inglês Computed Radiology) tem sido amplamente utilizada para auxiliar o diagnóstico médico em hospitais e clínicas em todo o mundo. Entretanto a rotina clínica comumente utiliza cartas de técnicas empregadas em sistemas tela-filme na aquisição de imagens em sistemas de detecção CR. As normativas internacionais já estabeleceram parâmetros de testes de controle de qualidade em CR. Entretanto as normativas nacionais trabalham para essa construção. Estudos recentes apontam métodos de otimização de imagens em sistema de detecção CR para exames de crânio, pelve e tórax para pacientes adulto e padrão sem se reportarem a exames de mão. Muitas doenças que acometem as mãos hoje em dia utilizam o exame de raios X como exame auxiliar para diagnóstico. Vale salientar que a técnica utilizada deve fornecer imagens com o máximo de informações possíveis para um diagnóstico seguro, com a menor dose ao paciente, e com redução de custos para a instituição onde os exames são realizados. Neste estudo um fantoma homogêneo de mão foi desenvolvido para ser utilizado no processo de otimização de imagens de mão utilizando sistema CR. Nesse procedimento foram quantificadas as espessuras de distintos tecidos que constituem um fantoma antropomórfico de mão a partir de exames de tomografia computadorizada. O mesmo procedimento foi adotado para 30 exames retrospectivos de pacientes do Hospital das Clínicas da Faculdade de Medicina de Botucatu- UNESP (HCFMB-UNESP). Os resultados obtidos apresentaram concordância entre as espessuras de tecidos que constituem o fantoma antropomórfico e a amostragem de pacientes avaliados, apresentando variações entre 12,63% e 6,48% para tecidos moles e ósseos, respectivamente. O fantoma homogêneo foi utilizado no processo de calibração do feixe de raios X, produzindo técnicas testes. Essas técnicas foram aplicadas em um fantoma antropomórfico de ... / Abstract: Computed Radiology (CR) has been widely used to assist medical diagnosis in hospitals and clinics worldwide. However clinical routine commonly use charts of techniques used in screen-film systems to obtain images in the detection CR systems. The international standards already established parameters of quality control tests in CR. However the national normative work for this construction. Recent studies suggest methods for optimizing images on CR systems for skull, pelvis and thorax exams for adult standard patients without reporting the exams of hand. Many diseases affecting hands today use the X-ray examination as an aid to diagnosis. It is noteworthy that the technique should provide images with maximum possible information for a safety diagnosis, with the lowest dose to the patient, and cost savings to the institution where the exams are performed. In this study a homogeneous phantom hand was developed to be used in the optimization of hand images using CR system. In this procedure were quantified thicknesses of different tissues that constitute an anthropomorphic phantom hand from CT scans. The same procedure was adopted for retrospective examinations of 30 patients of the Hospital das Clinicas, of School Medicine of Botucatu, UNESP (HCFMB-UNESP). The results showed agreement between the thicknesses of tissues that constitute the anthropomorphic phantom and sampling of patients, presenting variations between 12.63% and 6.48% for soft tissue and bone, respectively. The homogeneous phantom was used in the calibration of the X-ray beam process, producing tests technical. These techniques were applied in an anthropomorphic phantom hand from CT scans. The same procedure was adoped for retrospective examinations of 30 patients of the Hospital das Clinicas, of School Medicine of Botucatu, UNESP (HCFMB-UNESP). The results showed agreement between the thicknesses of tissues that constitute the anthropomorphic phantom and sampling of ... / Mestre
319

Avaliação da interface osso e implantes dentários em exames por imagem e suas implicações no diagnóstico

Vidor, Michele Machado January 2015 (has links)
Introdução: O desenvolvimento da radiologia digital e da tomografia computadorizada de feixe cônico (TCFC) permitiu aos profissionais diferentes formas de avaliação das imagens. Entretanto, frente a materiais metálicos, é observada a formação de artefatos tanto na imagem tomográfica, quanto nas radiografias digitais após a aplicação de filtros de processamento. Objetivo: Esta pesquisa objetivou investigar a interferência provocada por materiais metálicos na avaliação da interface osso/implante em radiografias periapicais convencional e digital, e em TCFC. Materiais e Métodos: Foram inseridos implantes de titânio em 74 blocos de costelas bovina frescas. Em 37, a inserção foi em íntima relação com as paredes ósseas (Grupo Controle-GC) e nos outros 37 com um espaço de 0.125 mm (Grupo Teste-GT). As radiografias periapicais foram realizadas com filme convencional e dois sistemas digitais de placa de fósforo. As imagens volumétricas foram adquiridas em dois equipamentos de TCFC. Nos sistemas digitais as imagens foram investigadas com e sem a utilização dos filtros e, nas tomografias, com diferentes protocolos de aquisição. Três examinadores treinados e cegados realizaram a avaliação utilizando uma escala Likert de cinco pontos. Foram utilizados testes de sensibilidade, especificidade e acurácia (área sob a curva ROC) e teste de concordância de Kendall (W). Resultados: Na avaliação radiográfica (ARTIGO I), foi observada maior acurácia do exame convencional e das imagens do sistema VistaScan com filtros Caries2 e Endo e do sistema Express com filtro Sharpen3 na detecção da justaposição entre osso e implante. Na avaliação tomográfica (ARTIGO II), somente as imagens do tomógrafo i-Cat com a resolução de voxel de 0.125mm não apresentaram diferença significativa com a radiografia convencional na acurácia diagnóstica. Conclusão: Na avaliação radiográfica da justaposição entre o osso e o implante, preferência deve ser dada às radiografias convencionais ou às digitais com filtros de realce (Caries2, Endo e Sharpen3). Em caso da existência de exames de TCFC com voxel 0.125 mm, tal avaliação também pode ser realizada. / Introduction: The development of digital radiology and computed tomography cone beam (CBCT) enabled professionals different possibilities of images evaluation. However, when metallic materials are present, artifacts formation can be observed in tomographic images and in digital radiography after processing fiters. Objective: This study investigated the interference caused by metallic materials in bone/implant interface evaluation with conventional and digital periapical radiographs, and CBCT. Materials and Methods: Titanium implants were placed into 74 fresh bovine ribs. In 37, the implants were in close relation with the bone walls (Control Group-CG) and the remaining 37 ribs preparations promoted a 0.125 mm space (Test Group-GT) .The periapical radiographs were taken with conventional film and digital photostimulable phosphor plate (PSP) system of two commercial brands. The volumetric images were acquired in two CBCT equipment. The digital images were investigated with and without the use of processing filters available and the tomographic with different acquisition protocol. Three trained and blinded examiners performed the evaluation using a five points Likert scale. Sensitivity, specificity and accuracy (area under the ROC curve) tests were used and Kendall´s coefficient of concordance (W). Results: In the radiographic evaluation (Article I), there was a higher accuracy to detect the juxtaposition between bone and implant with the conventional radiography and the images of VistaScan system using the Caries2 and Endo filters, and Express system with Sharpen3 filter. In the tomographic evaluation (Article II), only the images with 0.125mm of voxel resolution from i-Cat CBCT showed no significant difference with conventional radiography in the diagnostic accuracy. Conclusion: In radiographic evaluation of juxtaposition between bone and implant preference should be given to conventional radiographs or in digital radiographs to Caries2, Endo and Sharpen3 enhancement filters. In case of the existence of CBCT exams (voxel 0.125mm), such evaluation can also be performed.
320

Estudo de calcificações em tecidos moles em exames de tomografia computadorizada de feixe cônico utilizando diferentes softwares

Bruna Stuchi Centurion Pagin 22 June 2015 (has links)
O uso crescente da Tomografia Computadorizada de Feixe Cônico (TCFC) na área odontológica tem permitido o aumento dos achados incidentais em exames que são realizados por outros fins. Dentre essas uma, das mais comuns e com impacto na vida dos pacientes é o ateroma calcificado das artérias carótidas (ACAC), e no seu diagnóstico diferencial existem as ossificações das cartilagens da laringe. Para correta identificação dessas calcificações são necessários conhecimentos acerca da localização anatômica, distribuição e sua morfologia, sendo que a TCFC fornece uma localização tridimensional (3D) acurada. Entretanto existem diferentes softwares de pós-processamento de imagens disponíveis no mercado, e não há na literatura estudos sobre a capacidade desses softwares para a visualização dessas estruturas. Esse estudo tem o objetivo de identificar essas calcificações supracitadas, nos softwares de visualização de TCFC, i-Cat Vision® e Invivo5®, nas reconstruções multiplanares e 3D em dois grupos diferentes, sendo um grupo de exames de indivíduos com fissuras labiopalatinas (HRAC) (50 exames de TCFC) e outro sem fissuras labiopalatinas (FOB) (100 exames de TCFC). Foram avaliados 150 exames (112 do gênero feminino e 38 do gênero masculino) de TCFC por dois observadores devidamente treinados e calibrados. Para o grupo sem fissuras labiopalatinas foi encontrada diferença estatística significante entre a idade e a quantidade de calcificações encontradas. Considerando todas as calcificações, foram encontrados 104 indivíduos com alguma calcificação, representando 69,33% da amostra, sendo que o grupo HRAC apresentou 88% e o grupo FOB 59%. Foi possível demonstrar diferença estatística significante ao se comparar a quantidade de calcificações entre os grupos avaliados. Foi assumido nesse trabalho que as reconstruções separadamente do programa Invivo5® seria a padrão- ouro, nesse momento o programa i-Cat Vision® foi considerado mais específico do que sensível. Foram identificados muito falsos positivos no programa i-Cat Vision® e menores resultados para falso-negativos. Esse trabalho não tem o propósito de identificar os ACAC nos exames de TCFC, mas incentivar e demonstrar que é possível visualizar tais calcificações e diferenciá-las umas das outra, lembrando-se da responsabilidade do dentista em prevenir um problema futuro ao paciente que pode levar a quadros de morbidade e mortalidade. / The widespread use of CBCT in Dentistry leads to an increasing of incidental findings regarding exams for different purposes. The most common incidental finding that impacts the patients quality of life is the carotid artery calcifications as well as the ossification of laryngeal cartilage which is the most common differential diagnosis for aterosclerosis. To identify this calcifications/ossification correctly it is necessary to know about its anatomic localization, distribution and morphology once that CBCT images may evidence an accurate 3D location. Therefore many different manipulations imaging software for CBCT technology is available and there is no research in the literature about the capacity of this software to visualize these calcification/ossification structures. This study aimed to identify these calcifications/ossification, in two different visualization softwares: i-Cat Vision® and Invivo5®, both in Multiplanar Reconstruction (MPR) and 3D reconstruction, in two different groups, where one was constituted of cleft lip and palate (50 CBCT exams) patients and the other by patients without cleft lip and palate (100 CBCT exams). Two calibrated and trained observers evaluated 150 CBCT exams (112 were female and 38 male). There was significantly statistical difference when comparing age and calcifications quantity for no cleft lip and palate group. When considering all calcifications in both groups, 104 patients in 150 (total number) showed some calcification/ossification, representing 69,33%. The percentage of calcification/ossification in the cleft lip and palate group were 88% whereas the other one evidenced 59%. And due to this difference, there was significantly statistical difference between these groups. Besides, the Invivo5® software was considered the gold-standard (multiplanar reconstruction and 3D reconstruction) to identify the structures previously mentioned; then i-Cat Vision® software showed more specificity than sensitivity comparing the results with the Invivo5®. Many false positives were identified in i-Cat Vision® and only some false negatives, showing again the characteristics of these softwares. This work was not intended to identify carotid artery calcifications in CBCT exams, but in fact the real purpose was to demonstrate that it is possible to identify calcifications/ossifications and differentiate one of another. It is always important to remember about the dentistry knowledge and responsibility to prevent patient coming disease that may lead to morbidity and mortality situations.

Page generated in 0.057 seconds